Sundance Spas 680™ Series 2011 Owner's Manual

Add to my manuals
68 Pages

advertisement

Sundance Spas 680™ Series 2011 Owner's Manual | Manualzz

6 8 0

Burlington™ | Denali™ | Hartford™ | Hawthorne™ | Tacoma™

O w n e r ’ s m a n u a l

6530-681W Rev. B

Attention New Spa Owner!

Congratulations on the purchase of your new Sundance ® 680 Series spa! The following is a list of automated functions and maintenance recommendations for your new spa. Automated functions have been listed below in an attempt to suppress any operational concerns you may have during startup and the first 24 hours of ownership! Maintenance recommendations are listed in an attempt to stress their importance in protecting your new spa.

Automated Operations

Approximately two minutes after power is applied to the spa, the first filtration/ heating cycle turns on pump 1. In Hartford and Hawthorne models, an automatic five minute “blow-out” function also activates pump 2 for a period of five minutes to flush all lines. Then, after five minutes, pump 2 turns off and pump 1 continues to operate for the duration of the cycle.

Note: This function only occurs during the first filtration/heating cycle each day.

Maintain Healthy Spa Water

Always maintain your spa’s water chemistry within the following parameters as defined by the Association of Pool and Spa Professionals/USA: pH

Free Chlorine

Free Bromine

Total Alkalinity

Calcium Hardness

7.4-7.6

3.0-4.0 ppm

2.0-4.0 ppm

100-120 ppm

150-250 ppm

! TO DECREASE RISK OF INFECTION OR DISEASE! Always maintain your spa filter as outlined below to ensure healthy spa water. Refer to page

32 for additional information.

Required Filter Maintenance

Your new spa is equipped with an advanced water filtration system that provides unsurpassed water quality! To ensure maximum water quality at all times, you should clean and reuse both filter cartridges every month or as

needed. See page 32 for detailed filter cleaning/replacement instructions.

Required Water Maintenance

! TO DECREASE RISK OF INFECTION OR DISEASE! You should replace the spa’s water every 3 months. The frequency depends on a number of variables including frequency of use, number of users, and attention paid to water quality maintenance. You will know it is time for a change when you cannot control sudsing and/or you can no longer get the normal feel or sparkle to the water, even though the key water balance

measurements are all within the proper parameters. See pages 37-38 for

additional information.

© Sundance Spas, Inc. All Rights Reserved

680 SERIES

Table of Contents

1.0 Important Spa Owner Information ............................................ 1

2.0 FCC Notice .................................................................................. 1

3.0 Important Safety Instructions for all Spa Owners .................. 2

3.1 Entrapment Risk .......................................................................... 6

3.2 Hyperthermia ............................................................................... 7

3.3 Important CSA Safety Instructions (Canada only) ....................... 8

3.4 General Electrical Safety Instructions .......................................... 8

4.0 Choosing A Location ................................................................. 9

4.1 Outdoor Location ....................................................................... 10

4.2 Indoor Location .......................................................................... 10

5.0 Power Requirements ............................................................... 12

5.1 North American 60 Hz Power Options ....................................... 12

5.2 Export 50 Hz Power Options ..................................................... 14

6.0 Electrical Wiring Instructions ................................................. 15

7.0 Spa Fill Up Procedure .............................................................. 18

8.0 Control Functions .................................................................... 23

8.1 Control Panel ............................................................................. 23

8.2 General Spa Features And Controls .......................................... 24

9.0 Operating Instructions ............................................................ 25

9.1 Setting Water Temperature ....................................................... 25

9.2 Activate Pumps .......................................................................... 26

9.3 SunGlow™ Light Operation (Denali and Tacoma Models) ........ 26

9.4 Standard Light Operation (Burlington, Hartford and

Hawthorne Models) .................................................................. 26

9.5 Optional Multi-Colored LED Light System Operation

(Burlington, Hartford and Hawthorne Models) ........................... 26

9.6 Adjusting Individual Jet Flow ..................................................... 27

9.7 Selecting Desired Massage Action ........................................... 28

9.8 Air Controls ................................................................................ 28

9.9 Optional Audio System .............................................................. 28

10.0 Automatic Filtration Cycles .................................................... 29

10.1 Standard Filtration/Heating Modes For Models Without

Circulation Pump Option ............................................................ 29

10.2 Standard Filtration/Heating Modes For Models With

Circulation Pump Option ............................................................ 29

680 SERIES

10.3 Economy Filtration/Heating Modes (F4-F6) ............................... 29

10.4 Lock Modes (L1-L2) ................................................................... 29

10.5 Selecting The Filtration/Heating Mode ...................................... 30

10.6 Filtration Modes for Spas Without Circulation Pump Option ..... 30

10.7 Filtration Modes for Spas With Circulation Pump Option .......... 31

11.0 Spa Maintenance...................................................................... 32

11.1 Cleaning The Filter .................................................................... 32

11.2 Draining and Refilling ................................................................ 33

11.3 Pillow Care (All Models Except Denali) ..................................... 34

11.4 Cleaning The Spa Interior .......................................................... 34

11.5 Maintaining The Cover .............................................................. 35

11.6 Maintaining The Synthetic Cabinet ............................................ 36

11.7 Winterizing ................................................................................. 36

11.8 Restarting Your Spa in Cold Weather ........................................ 37

12.0 Water Quality Maintenance ..................................................... 37

12.1 pH Control ................................................................................. 37

12.2 Sanitizing ................................................................................... 38

12.3 CD Ozone Water Maintenance System ..................................... 38

13.0 Error Conditions/Error Messages .......................................... 39

13.1 Summer Logic (Spas With Circulation Pump Option) ................ 39

13.2 Panel displays SN1 ................................................................... 39

13.3 Panel displays SN2 ................................................................... 39

13.4 Panel Flashes FL1 or FL2 (Spas Without Circulation

Pump Option) ............................................................................ 39

13.5 Panel Flashes FL1 or FL2 (Spas With Circulation

Pump Option) ............................................................................ 40

13.6 Panel displays COL ................................................................... 40

13.7 Panel Displays ICE .................................................................... 40

13.8 Panel Displays OH .................................................................... 40

13.9 Panel displays - - - .................................................................... 41

14.0 Troubleshooting Procedures .................................................. 41

14.1 None of the Components Operate (e.g. Pump, Light) .............. 41

14.2 Pump Does Not Operate but Light Does ................................... 41

14.3 Poor Jet Action .......................................................................... 42

14.4 Water is Too Hot ........................................................................ 42

14.5 No Heat ..................................................................................... 42

680 SERIES

15.0 North American Denali/Tacoma Convertible Circuit

Diagram (60 Hz) ........................................................................ 43

16.0 North American Burlington Models (60 Hz) .......................... 44

17.0 North American Hartford and Hawthorne Models (60 Hz) ... 45

18.0 Export Denali/Tacoma Circuit Diagram (50 Hz) ..................... 46

19.0 Export Burlington Circuit Diagram (50 Hz) ............................ 47

20.0 Export Hartford and Hawthorne Circuit Diagram (50 Hz) ..... 48

21.0 Optional Audio Receiver Functions (Burlington,

Hartford and Hawthorne Models Only) .................................. 49

21.1 Audio Receiver Control Functions ............................................. 49

21.2 Stereo Audio Receiver Specifications ........................................ 57

21.3 CD/MP3/WMA folder/file hierarchy ............................................ 58

21.4 Stereo Audio Receiver Troubleshooting .................................... 60

.

680 SERIES

680 SERIES

1.0 Important Spa Owner Information

Your Sundance ® 680 Series spa is constructed to the highest standards and is capable of providing many years of trouble-free use. However, because heat retentive materials are utilized to insulate the spa for efficient operation, an uncovered spa surface and wall fittings directly exposed to sunlight and high temperatures for an extended period are subject to permanent damage or discoloration. Damage caused by exposing the spa to this abuse is not covered under warranty.

We recommend that you always keep the spa full of water when it is exposed to direct sunlight and that you keep the Sundance premium insulating cover in place at all times when the spa is not in use. Read and carefully follow the requirements for your spa’s support base found

in Section 4.0 titled, “Choosing a Location” (page 9).

Sundance constantly strives to offer the finest spas available, therefore modifications and enhancements may be made which affect the specifications, illustrations and/or instructions contained herein.

2.0 FCC Notice

This equipment has been tested and found to comply with the limits for a Class B Digital Device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

1. Rearrange or relocate the receiving antenna.

2. Increase the separation between the equipment and receiver

3. Connect the equipment into an outlet on a circuit different from the circuit connected.

4. Consult the dealer or an experienced radio/TV technician for help.

Changes or modifications not expressly approved by the party responsible for FCC compliance could void the user’s authority to operate this equipment.

Page 1

680 SERIES

3.0 Important Safety Instructions for all Spa Owners

READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY!

This spa was manufactured to meet the standards and specifications outlined in the “Virginia Graeme Baker Pool and Spa Safety Act” (VGB

Safety Act). When installing and using this spa, basic safety precautions should always be followed, including:

1.

!

DANGER:

RISK OF SEvERE INjURY OR DROWNING!

Extreme caution must be exercised to prevent unauthorized access by children.

To avoid accidents, ensure that children do not use this spa unless supervised at all times. Adult supervision is a critical safety factor in preventing children from drowning.

Use the straps and clip tie downs to secure the spa cover when not in use. This will help discourage unsupervised children from entering the spa. Keep the spa cover secure in high-wind conditions.

There is no representation that the cover, clip tie-downs, or actual locks will prevent access to the spa.

2.

3.

!

DANGER:

RISK OF SEvERE INjURY OR DROWNING!

Keep hair, loose articles of clothing or hanging jewelry away from suction fittings, rotating jets or other moving components to avoid entrapment that could lead to drowning or severe injury.

Never use the spa unless all suction guards, filter, filter lid, or skimmer assembly are installed to prevent body and/or hair entrapment.

Never operate or use the spa if the filter, filter lid, or skimmer assembly are broken or any part of the skimmer assembly is missing. Please contact your dealer or nearest service center for service.

The suction fittings and suction covers in this spa are sized to match the specific water flow created by the pump(s). If it is necessary to replace the suction fittings, suction covers or pump(s), be sure that the flow rates are compatible and are in compliance with the VGB Safety Act.

Never replace a suction fitting or suction cover with one rated less than the flow rate marked on the original suction fitting. Using improper suction fittings or suction covers can create a body or hair suction entrapment hazard that may lead to drowning or severe injury.

!

DANGER:

RISK OF SEvERE INjURY FROM ELECTRIC

SHOCK OR DEATH FROM ELECTROCUTION!

Install the spa at least 5 feet (1.5m), from all metal surfaces. As an alternative, a spa may be installed within 5 feet of metal surfaces if each metal surface is permanently connected (bonded) by a minimum No. 8

AWG (8.4 mm²) solid copper conductor attached to the wire connector on the grounding lug, inside the equipment compartment on the equipment box.

Page 2

680 SERIES

4.

A grounding wire connector is provided on this unit to connect a minimum No. 8 AWG (8.4 mm²) solid copper conductor between this unit and any metal equipment, metal enclosures of electrical equipment, metal water pipe, or conduit within 5 feet (1.5m) of the unit.

Never permit any electrical appliance, such as a light, telephone, radio, television, etc. within 5 feet (1.5m) of a spa unless such appliances are built-in by the manufacturer.

Never bring any electrical appliances into or near the spa.

Never operate any electrical appliances from inside the spa or when you are wet.

The electrical supply for this product must include a suitably rated switch or circuit breaker to open all ungrounded supply conductors to comply with section 422-20 of the National Electrical Code/USA, ANSI/NFPA 70.

The disconnecting means must be readily accessible and visible to the spa occupant but installed at least 5 feet (1.5m), from the spa.

The electrical circuit supplied for the hot tub must include a suitable ground fault circuit interrupter (GFCI) as required by NEC Article 680-42.

!

WARNING:

RISK OF SEvERE INjURY OR DEATH!

Extreme caution must be exercised to prevent diving or jumping into the spa or slipping and falling, which could result in unconsciousness, drowning, or serious injury. Remember that wet surfaces can be very slippery.

Never stand, walk or sit on the top railing of the spa.

5.

!

WARNING:

RISK OF HYPERTHERMIA (OvER-HEATING)

CAUSING SEvERE INjURY, BURNS, WELTS OR DEATH!

Water temperature in excess of 104°F (40°F) may be injurious to your health.

Refer to section 3.2 Hyperthermia for specific causes and symptoms of this condition.

The water in the spa should never exceed 104°F (40°C). Water temperatures between 100°F (38°C) and 104°F (40°C) are considered safe for a healthy adult.

Lower water temperatures are recommended for young children

(children are especially sensitive to hot water) and when spa use may exceed 10 minutes.

The Consumer Products Safety Commission/USA has stated that the water temperature in a spa should not exceed 104°F (40°C).

Always test the spa water temperature before entering the spa. The user should measure the water temperature with an accurate thermometer since the tolerance of water temperature-regulating devices may vary as much as +/- 5°F (2°C).

Page 3

680 SERIES

6.

!

WARNING:

RISK OF SEvERE INjURY OR DEATH!

Since excessive water temperatures have a high potential for causing fetal damage during the early months of pregnancy, if pregnant or possibly pregnant, consult your physician before using a spa.

Pregnant or possibly pregnant women should limit spa water temperatures to 100°F (38°C).

Persons suffering from obesity or a medical history of heart disease, low or high blood pressure, circulatory system problems, diabetes, infectious diseases or immune deficiency syndromes should consult a physician before using a spa.

If you experience breathing difficulties in association with using or operating your spa, discontinue use and consult your physician.

Persons using medication should consult a physician before using a spa since some medication may induce drowsiness, while other medication may affect heart rate, blood pressure, and circulation.

Persons suffering from any condition requiring medical treatment, the elderly, or infants should consult with a physician before using a spa.

The use of alcohol, drugs, or medication before or during spa use may lead to unconsciousness with the possibility of drowning.

7.

!

WARNING:

RISK OF SEvERE INjURY OR DEATH!

Prolonged immersion in a spa may be injurious to your health.

Observe a reasonable time limit when using the spa. Exposures at higher temperatures can cause high body temperature (over-heating).

Symptoms may include dizziness, nausea, fainting, drowsiness, and reduced awareness. These effects could possibly result in drowning or serious injury.

Never use a spa immediately following strenuous exercise. Enter and exit the spa slowly. Wet surfaces can be slippery.

8.

!

WARNING:

TO DECREASE RISK OF INFECTION OR

DISEASE!

To reduce the risk of contracting a waterborne illness (e.g. an infection, bacteria or virus) and/or respiratory ailments, maintain water chemistry within the parameters listed on the inside cover of this manual and consult with a licensed engineer regarding proper ventilation if installed indoors or in an enclosed area.

People with infectious diseases should not use a spa to avoid water contamination, which could result in spreading infections to others.

Always shower before and after using your spa. Maintain water chemistry in accordance with manufacturer’s instructions. Failure to do so may result in contracting a waterborne illness (e.g. an infection, bacteria or virus).

Page 4

680 SERIES

9.

!

WARNING:

In addition to maintenance of filters and water chemistry, proper ventilation is recommended to reduce the risk of contracting a waterborne illness (e.g. an infection, bacteria or virus) and/or respiratory ailments that could be present in the air or water.

Consult a licensed architect or building contractor to determine your specific needs if installing your hot tub indoors.

10. CAUTION: TO DECREASE RISK OF PRODUCT DAMAGE.

Maintain water chemistry in accordance with manufacturer’s instructions.

Proper chemical maintenance of spa water is necessary to maintain safe water and prevent possible damage to spa components.

11. NOTE:

• This spa is not intended nor designed to be used in a commercial or public application. The spa buyer shall determine whether there are any code restrictions on the use or installation of this spa since local code requirements vary from one locality to another.

Hot Tub Safety Literature

To ensure you have a safe and enjoyable hot tub experience, learn all you can about hot tub safety and emergency procedures.

Especially useful are the brochures listed below:

Children Aren’t Waterproof

Pool and Spa Emergency Procedures For Infants and Children

Layers of Protection

The Sensible Way to Enjoy Your Spa or Hot Tub

The Association of Pool and Spa Professionals publishes these brochures. To acquire a brochure:

Ask your hot tub dealer (they may have copies)

Go to

• http://apsp.org

Conduct your own search on the internet

Write to the following address:

The Association of Pool and Spa Professionals

2111 Eisenhower Avenue

Alexandria VA 22314

703.838.0083

Page 5

680 SERIES

3.1 Entrapment Risk

The Consumer Products Safety Commission/USA has reported that users of pools and spas have become entrapped (stuck) to drain and/or suction fittings causing death, drowning, or serious injury (see diagram below). This spa was manufactured to meet the standards and specifications outlined in the “Virginia Graeme Baker Pool and Spa Safety Act”

(VGB Safety Act). Entrapment risk can be minimized if proper precautions are taken.

!

DANGER:

RISK OF PERSONAL INjURY OR DEATH!

Never operate the spa if a suction fitting, suction cover, filter, filter lid or skimmer assembly are broken, damaged or missing.

Filter, Filter

Lid, Skimmer

Assembly

(location and style vary by models)

Suction Fittings,

Suction Covers

(locations vary by models)

1.

!

DANGER:

RISK OF SEvERE INjURY OR DROWNING!

Hair entrapment: May occur if hair is entangled, knotted or snagged in a drain suction or skimmer assembly. This has been reported in persons who when submerge themselves underwater, allowing hair to come close and/or within the reach of the suction fittings, suction covers or skimmer assembly.

Keep hair away from suction fittings, suction covers, filter, filter lid or skimmer assembly.

Children are at risk for hair entrapment if swimming under water.

Never allow children to play or get near the suction fittings, suction covers, filter, filter lid or skimmer assembly.

2.

!

DANGER:

RISK OF SEvERE INjURY OR DROWNING!

Limb entrapment: May occur when a limb becomes entrapped, inserted or sucked into a suction or outlet opening.

Always keep suction fittings, suction covers, filter, filter lid or skimmer assembly in place when operating to avoid limb entrapment.

Never allow children to play or get near the suction fittings, suction covers, filter, filter lid or skimmer assembly.

Page 6

680 SERIES

3.

!

DANGER:

RISK OF SEvERE INjURY OR DROWNING!

Body entrapment: May occur when part of the torso becomes entrapped, inserted or sucked into a suction or outlet opening.

Never allow children to play or get near the suction fittings, suction covers, filter, filter lid or skimmer assembly.

4.

!

DANGER:

RISK OF SEvERE INjURY OR DROWNING!

Evisceration (disembowelment) entrapment: May occur when the buttocks becomes entrapped, inserted or sucked into a suction or outlet opening.

Never sit on suction fittings, suction covers, filter, filter lid or skimmer assembly.

Never allow children to play or get near the suction fittings, suction covers, filter, filter lid or skimmer assembly.

5.

Mechanical entrapment: May occur when jewelry, swimsuit, or

!

DANGER:

RISK OF SEvERE INjURY OR DROWNING!

hair accessories become entangled, knotted or snagged in a drain suction or skimmer assembly.

Never allow your jewelry, swimsuit, or hair accessories to come close to the suction fittings, suction covers or skimmer assembly.

Never allow children to play or get near the suction fittings, suction covers, filter, filter lid or skimmer assembly.

3.2 Hyperthermia

Prolonged immersion in hot water may induce hyperthermia (overheating). The use of alcohol or drugs can greatly increase the risk of fatal hyperthermia in spas. A description of the causes, symptoms, and effects of hyperthermia are as follows:

Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the normal body temperature of 98.6°F

(37°C). The symptoms of hyperthermia include drowsiness, lethargy

(fatigue), and an increase in the internal temperature of the body (feeling of being too hot). The effects of hyperthermia include:

Unawareness of impending hazard;

Failure to perceive heat;

Failure to recognize the need to exit spa;

Physical inability to exit spa;

Fetal damage in pregnant women; and

Unconsciousness and danger of drowning.

Page 7

680 SERIES

A Warning Sign is provided in your warranty packet. Please install at a location near your spa, where it is visible to users of the spa. For additional or replacement Warning Signs please contact your local

Sundance spas dealer and reference item number #6530-082.

3.3 Important CSA Safety Instructions (Canada only)

When using this electrical equipment, basic safety precautions should always be followed, including the following:

1. READ AND FOLLOW ALL INSTRUCTIONS.

2. A green colored terminal or a terminal marked G, Gr, Ground,

Grounding or the symbol* is located inside the supply terminal box or compartment. To reduce the risk of electric shock, this terminal must be connected to the grounding means provided in the electric supply service panel with a continuous copper wire equivalent in size to the circuit conductors that supply this equipment

(*IEC Publication 417, Symbol 5019).

3. At least two lugs marked “Bonding Lugs” are provided on the external surface or on the inside of the supply terminal box/ compartment. To reduce the risk of electric shock, connect the local common bonding grid in the area of the spa to these terminals with an insulated or bare copper conductor not smaller than No. 6 AWG

(10 mm²).

4. All field-installed metal components such as rails, ladders, drains or other similar hardware within 10 feet (3m) of the spa shall be bonded to the equipment grounding buss with copper conductors not smaller than No. 6 AWG (10 mm²).

5. SAvE THESE INSTRUCTIONS.

3.4 General Electrical Safety Instructions

Your new Sundance ® spa is equipped with a “state-of-the-art” equipment system. It contains the most advanced safety and self-protective equipment in the industry. Nonetheless, this spa must be installed properly to ensure dependable usage. Please contact your local

Sundance dealer or local building department should you have any questions regarding your installation.

Proper grounding is extremely important. Sundance spas are equipped with a current collector system. A pressure wire connector is provided on the surface of the control box, located outside the equipment door

(Figure B, page 17) to permit connection of a bonding wire between

this point and any ground metal equipment, metal water pipe or conduit within 5 feet (1.5m) of the spa, or copper clad grounding rod buried

Page 8

680 SERIES within 5 feet (1.5m) of the spa. Bonding wire must be at least No. 8 AWG

(8.4 mm²) solid copper wire. This is a most important safety assurance feature.

Before installing your spa, check with your local building department to insure installation conforms to local building codes.

120/240 volt Denali And Tacoma Convertible Models

A spa connected to a 120 VAC electrical service must be located close enough to a grounded, grounding-type electrical outlet so that the included 10 foot (3m) power cord can be plugged directly into it. DO NOT

USE AN EXTENSION CORD as this could cause damage to the spa’s equipment due to insufficient voltage. The power supplied to this spa must be a dedicated circuit with no other appliances or lights sharing the power provided by the circuit.

4.0 Choosing A Location

IMPORTANT: Because of the combined weight of the spa, water and users, it is extremely important that the base upon which the spa rests be smooth, flat, level and capable of uniformly supporting this weight, without shifting or settling, for the entire time the spa is in place. If the spa is placed on a surface which does not meet these requirements, damage to the skirt and/or the spa shell may result. Damage caused by improper support is not covered under warranty. It is the responsibility of the spa owner to assure the integrity of the support over time. We recommend a poured, reinforced concrete slab with a minimum thickness of 4 inches

(10 cm). Wood decking is also acceptable provided it is constructed so that it meets the requirements outlined above.

!

WARNING:

For spas that are to rest on balconies, roofs or other platforms not specifically tied into main

structural support, consult a professional Structural

Engineer with experience in this type of application.

The spa must be installed in such a manner as to provide drainage away from it. Placing the spa in a depression without provisions for proper drainage could allow rain, overflow and other casual water to flood the equipment and create a wet condition in which it would sit in. For spas

Page 9

680 SERIES which will be recessed into a floor or deck, install so as to permit access to the equipment, either from above or below, for servicing. Make certain that there are no obstructions which would prevent removal of all side cabinet panels and access to the jets components, especially on the side with the equipment bay.

CAUTION:

If the spa is indoors or located in an enclosed area, proper ventilation should be discussed with an Engineer or authority competent enough to understand the necessary provisions needed to vent moist or heated air and air associated with chemical odors outdoors. When the spa is in use considerable amounts of

moisture will escape potentially causing mold and mildew. This can cause health risk. Over time, this can damage certain surfaces, surroundings, and equipment.

4.1 Outdoor Location

In selecting the ideal outdoor location for your spa, we suggest that you take into consideration the following:

The proximity to changing area and shelter (especially in regions subject to cold weather).

The pathway to and from your spa (this should be free of debris so that dirt and leaves are not easily tracked into the spa).

The closeness to trees and shrubbery (remember that leaves and birds could create extra work in keeping the spa clean).

A sheltered environment (less wind and weather exposure can result in lowered operation and maintenance costs).

The overall enhancement of your environment. It is preferable not to place the spa under an unguttered roof overhang since run-off water will shorten the life expectancy of the spa cover.

For spas that are to rest on balconies, roofs or other platforms not specifically tied into main structural support, consult a professional

Structural Engineer with experience in this type of application.

4.2 Indoor Location

For indoor installations many factors need to be considered before installing a spa indoors:

!

WARNING:

In addition to maintenance of filters and water chemistry, proper ventilation is recommended to reduce the risk of contracting a waterborne illness (e.g. an infection, bacteria or virus) and/or respiratory ailments that could be present in the air or water. Consult a licensed architect or building contractor to determine your specific needs if installing your hot tub indoors.

Page 10

680 SERIES

PROPER FOUNDATION : Consult a Structural Engineer when considering a foundation that will adequately support the spa

the entire time it is in place. Proper support is critical especially if the spa is to rest on a second story or higher. For spas that are to rest on balconies, roofs or other platforms not specifically tied into the main structural support, you should consult a professional Structural

Engineer with experience in this type of application.

PROPER DRAINAGE . It is extremely important to have in place

measures to sufficiently handle excessive water spillage. Be sure the flooring in which the spa rests on has adequate drainage and can handle draining of the entire contents of the spa. Be sure to make provisions for ceilings or any other structures that may be below the spas installation. Areas around your spa can become wet or moist so all flooring and subsequent furniture, walls and adjacent structures should be able to withstand or resist water and moisture.

PROPER vENTILATION .

Proper ventilation should be discussed with an Engineer or authority competent enough to understand the necessary provisions needed to vent moist or heated air and

air associated with chemical odors outdoors. When the spa is in use considerable amounts of moisture will escape potentially causing mold and mildew, over time this can damage certain surfaces and or surroundings.

SUFFICIENT ACCESS . In the unlikely event that you should ever need to access or gain entry to any portion of the spa for servicing, it is highly recommended that you plan your indoor installation to provide full access to the entire spa.

WARRANTY . Damage caused by not following these guidelines or any improper installation not in accordance with local codes or authorities is not covered under the spas warranty. Please consult your local state or city building ordinances.

Page 11

680 SERIES

5.0 Power Requirements

Sundance ® spas are designed to provide optimum performance and flexibility of use when connected to the

maximum electrical service listed on pages 12-14. If you

prefer, your dealer can perform a minor circuit board modification to allow your spa to accept an electrical service other than the factory setting.

Note: Refer to pages 43-48 for circuit board configuration details or

contact your authorized Sundance dealer.

5.1 North American 60 Hz Power Options

North American Denali/Tacoma 1-Pump Convertible Models (60 Hz)

Voltage:

# of Wires:

120v/15A*

120 VAC

3 (15A GFCI Cord -

240v/30A*

240 VAC

4 (Hard

240v/40A**

240 VAC

4 (Hard

Frequency:

Current Draw:

Circuit Breaker:

US Models Only*)

60 Hz

12A

15A, 1-Pole

Wired Only)

60 Hz

21A

30A, 2-Pole

Wired Only)

60 Hz

30A

40A, 2-Pole

CAUTION (For 4-wire, 240 vAC Heater Operation): Move the red wire on the main terminal strip (TB1) from position #1 to position #3. Make certain wires

are connected exactly as shown in Figure D (page 17) before applying power.

Failure to do so will result in damage to the circuit board and/or related components and void the manufacturer’s warranty.

* In the 15A/30A configuration, the heater will not operate at the same time as the high-speed jets pump. The factory setting is 120v/15A.

*Note: all Canadian spas must be hard wired (120 vAC or 240 vAC)

per CSA Canadian standards (page 8).

** If the spa is to be operated on 40A service, remove the jumper JP1 #1-2 on the circuit board to allow the heater to operate at the same time as the

high-speed jets pump (page 43).

Page 12

680 SERIES

North American Burlington 1-Pump Models (60 Hz)

240v/40A* 240v/50A**

Voltage:

# of Wires:

Frequency:

Current Draw:

Circuit Breaker:

240 VAC

3

60 Hz

26A

40A, 2-Pole

240 VAC

3

60 Hz

36A

50A, 2-Pole

* In the 40A configuration, the heater will not operate while the jets pump is running in high speed.

** In the 50A configuration, the heater will operate while the jets pump is running in high speed. This is the factory setting.

North American Hartford and Hawthorne 2-Pump Models (60 Hz)

240v/40A* 240v/50A** 240v/60A***

Voltage:

# of Wires:

Frequency:

Current Draw:

Circuit Breaker:

240 VAC

3

60 Hz

26A

40A, 2-Pole

240 VAC

3

60 Hz

36A

50A, 2-Pole

240 VAC

3

60 Hz

45A

60A, 2-Pole

* In 40A configuration, the heater will not operate while either jets pump is running in high speed. Note: pump 2 runs only in high speed.

** In 50A configuration, the heater will not operate while both jets pumps are running in high speed. Note: pump 2 runs only in high speed. This is the factory setting.

*** In 60A configuration, the heater will operate while both jets pumps are running in high speed. Note: pump 2 runs only in high speed.

Page 13

680 SERIES

5.2 Export 50 Hz Power Options

Export Burlington, Denali and Tacoma 1-Pump Models (50 Hz)

230v/20A* 230v/30A**

Voltage:

# of Wires:

Frequency:

Current Draw:

Circuit Breaker:

230 VAC

3

50 Hz

15A

20A

230 VAC

3

50 Hz

21A

30A

* In the 20A configuration, the heater will not operate while the jets pump is running in high speed. This is the factory setting.

** In the 30A configuration, the heater will operate while the jets pump is running in high speed.

Export Hartford and Hawthorne 2-Pump Models (50 Hz)

Voltage:

# of Wires:

Frequency:

Current Draw:

Circuit Breaker:

230v/20A*

230 VAC

3

50 Hz

15A

20A

230v/30A**

230 VAC

3

50 Hz

23A

30A

230v/40A***

230 VAC

3

50 Hz

29A

40A

* In the 20A configuration, the heater will not operate while either jets pump is running in high speed. This is the factory setting.

** In the 30A configuration, the heater will not operate while both jets pumps are running in high speed.

*** In the 40A configuration, the heater will operate while both jets pumps are running in high speed.

Page 14

680 SERIES

6.0 Electrical Wiring Instructions

IMPORTANT NOTICE: The electrical wiring of this spa must meet the requirements of the National Electrical Code/

USA (NEC) and any applicable state or local codes. The electrical circuit must be installed by a qualified electrician and approved by a local building/electrical inspection authority.

1. Convertible 120/240v Denali/Tacoma Models Only:

PRODUCT DAMAGE OR ELECTRICAL FIRE.

120V “Plug-in” Operation: This spa must operate on the supplied 10

!

DANGER:

TO DECREASE THE RISK OF SHOCK, feet (3m) 120V GFCI cord at its original length or must be hard-wired for longer runs. NEvER USE AN EXTENSION CORD FOR ANY

REASON!

Convertible 120/240V Heater Operation: The included 120V GFCI cord must be discarded for 240V heater operation. This spa must be hard-wired. Supplying power to either configuration above which is not in accordance with these instructions will void both the independent testing agency listing and the manufacturer’s warranty.

2. Dedicated 240v Burlington, Hartford and Hawthorne Models:

This spa must be permanently connected (hard-wired) to the power supply. No plug-in connections or extension cords are to be used in conjunction with the operation of this spa. Supplying power to the spa which is not in accordance with these instructions will void both the independent testing agency listing and the manufacturer’s warranty.

3. The power supplied to this spa must be a dedicated circuit with no other appliances or lights sharing the power provided by the circuit.

4. To determine the current, voltage and wire size required, refer to

Section 5.0 “Power Requirements” (pages 12-14).

Wire size must be appropriate per NEC and/or local codes.

We recommend type THHN wire.

All wiring must be copper to ensure proper connections. Do not use aluminum wire.

When using wire larger than #6 (10 mm²), add a junction box near the spa and reduce to short lengths of #8 (8.4 mm²) wire to connect to the spa.

Page 15

680 SERIES

5. The electrical supply for this product must include a suitably rated switch or circuit breaker to open all ungrounded supply conductors to comply with Section 422-20 of the National Electrical Code/USA,

ANSI/NFPA 70. The disconnecting means must be readily accessible to the spa’s occupant but installed at least 5 feet (1.5m) from spa water.

6. The electrical circuit supplied for the spa must include a suitable ground fault circuit interrupter (GFCI) as required by NEC Article

680-42.

7. To gain access to the spa’s power terminal block, remove the screws securing the cabinet panel on the side of the spa under the control panel. Then remove the four control box door screws and door

(Figures A-B, pages 16-17).

8. Select the power supply inlet you want to use (Figure A). Feed power cable to control box, then install it through the large opening provided in the bottom side of the box.

9. Connect wires, color to color, on terminal blocks TB1 and TB3

(Figures C-F, page 17). TIGHTEN SECURELY! All wires must be

hooked up securely or damage could result.

10. Install control box door and screws and reinstall the cabinet side panels.

Figure A

Equipment Area

7

Flow

8

1

4

6

9

3

2 2

5 5

Note: Pump locations vary by model

1. Control Box

2. Power Supply Inlet(s)

3. 2-Speed Pump #1

4. Heater

5. Pump Drain Plugs

6. 1-Speed Pump #2

7. Control Panel

Page 16

8. Ozone Injector

9. Optional CD Ozonator (Purchased separately on

North American models; standard equipment on export models; location varies by model)

(Model shown with Hi-Flow heater and no circulation pump)

680 SERIES

Figure B

Control Box

2

TB1

1

3

1. Terminal Block

2. Bonding Lug

3. Grounding Terminal

Figure C Figure D

WHT

1

BLK

2

3

TB1

WHT

RED

BLK

BLK to Circuit

Board

GRN

North American Denali/Tacoma Convertible

Models: 120 VAC, 3-Wire Connection (60 Hz)

WHT

1

TB1 to Circuit

Board

WHT

RED

BLK

2

RED

3

BLK

BLK

RED

Move Red

Wire Here

GRN

North American Denali/Tacoma Convertible

Models: 240 VAC, 4-Wire Connection (60 Hz)

CAUTION (For 4-wire 240 VAC Heater Operation): Move the red wire on the main terminal strip (TB1) from position #1 to position #3. Make certain wires are connected exactly as shown in Figure D before applying power. Failure to do so will result in damage to the circuit board and/or related components and void the manufacturer’s warranty.

Figure F Figure E

RED

1

BLK

2

Green

TB1

RED

RED

BLK

BLK to Circuit

Board

TB3

North American Burlington, Hartford

and Hawthorne Models:

240 VAC, 3-Wire Connection (60 Hz)

TB1

BLUE

BLUE

1

2

Green

BROWN

BROWN to Circuit

Board

TB3

All Export Models:

230 VAC, 3-Wire (50 Hz)

Page 17

680 SERIES

7.0 Spa Fill Up Procedure

For best results, read each step in its entirety before proceeding with that step.

1. Prepare The Spa For Filling

• Clear all debris from the spa. (Although the spa shell has been

• polished at the factory, you may want to treat it with a specially formulated spa cleaner). Consult your authorized Sundance dealer for additional information prior to filling spa.

Remove filter/skimmer lid (page

24), then remove filter cartridge

as outlined in Section 11.1 (page 32).

2. Fill Spa

• Place the end of your garden hose into the empty filter bucket.

CAUTION: TO DECREASE BUILD UP ON COMPONENTS AND

MINIMIZE ACRYLIC DAMAGE.

Never fill with water from a water softener. If your water is extremely

“hard”, it is preferable to fill half-way with hard water and the rest of the way with softened water. Water that is too soft can be corrosive to metal components.

!

WARNING:

TO DECREASE RISK OF INFECTION OR

DISEASE.

Fill hot tub with clean tap water from garden hose, to reduce risk of contracting a waterborne illness (e.g. an infection, bacteria or virus) and/or respiratory ailments. Fill until water covers all jets but does not touch the bottom of the lowest headrest. (DO NOT OVERFILL!)

IMPORTANT: Always fill your spa through the filter bucket after draining. Failure to do so may cause air to be trapped in either pump, preventing the pump from circulating water. Remove the hose and replace the filter cartridge. Note: DO NOT overtighten filter cartridge, finger tight only!

3. Turn On Power

Turn on power to spa at the home’s circuit breaker to start boot up

sequence (Section 9.0, page 25). The heater and filter pump will

automatically activate after several seconds. If the control panel LED flashes water temperature and “COOL” or “ICE” this is normal, refer

to page 40 for additional information.

Page 18

680 SERIES

4. Activate jets Pumps

Turn on all jet(s) pumps to ensure proper mixing when adding start-up chemical in step 5.

1

5. Add Start-Up Chemicals

Add the spa water chemicals as recommended by your authorized

Sundance dealer. See Section titled “Water Quality Maintenance”

(page 37) for general guidance.

2

!

WARNING:

RISK OF POISONING OR DEATH.

Never leave chemicals opened and accessible to anyone.

Use chemicals according to the vendors instructions. Always store chemicals in a safe and/or locked location. Keep away from and out of reach of children.

6. Establish A Stable Sanitizer Reading

Establish a stable sanitizer reading between 3.0-4.0 ppm chlorine or 2.0-4.0 ppm bromine. To ensure healthy water conditions, always maintain a constant sanitizer reading within the levels recommended by the Association of Pool and Spa Professionals/USA printed on the inside cover of this manual. If sanitizer levels cannot be stabilized, perform the decontamination procedure steps 9-15 on the following page.

Note: The “decontamination procedure” steps 9-15 should also be used

after the spa has been “Winterized” (Section 11.7, page 36) or has been

sitting without power for an extended period.

7. Set Spa To Heat

To warm spa water to a comfortable temperature, follow

• these steps:

The LED

• display on the control panel displays the actual temperature of the spa water. Press either the COOLER ( ) or WARMER

( ) button once to display the “set” temperature for 5 seconds.

If you want the water to heat to a different temperature, simply press COOLER or WARMER within 5 seconds. The set temperature increases or decreases by one degree each time one of these buttons is pressed.

The heater will turn off when the temperature corresponding to the thermostat setting is achieved.

Page 19

680 SERIES

Important Heater Details:

• The maximum temperature for which the spa can be set is 104°F

(40°C) and the minimum is 65°F (18°C).

• For North American (60 Hz) 2-pump spas powered by a 40 amp service, jets pump #1 must be set to low speed and jets pump #2 must be turned off to operate the heater.

• For Export (50 Hz) 2-pump spas powered by a 20 amp service, jet pump #1 must be set to low speed and jets pump #2 must be turned off to operate the heater.

• Setting the thermostat at maximum will not accelerate the heating process. This will only result in a higher ultimate temperature.

• The heater operates until the water reaches the programmed “set temperature”, then turns off. The heater will reactivate after the water cools to approximately 1.5° below the “set temperature.”

8. Place Cover On Spa

• Keeping the insulating cover in place anytime the spa is not in

• use will reduce the time required for heating, thereby minimizing operating costs.

The time required for initial heat-up will vary depending on the starting water temperature.

!

DANGER:

RISK OF PERSONAL INjURY.

Check water temperature carefully before entering hot tub!

Excessive water temperature can cause burns, welts and body temperature to rise, hyperthermia (over-heating).

Decontamination Procedure (Steps 9-15)

Steps 9-15 below are only required when sanitizer levels are unstable after performing steps 1-6 above. Disregard steps 9-15 below if sanitizer levels remain stable at 3.0-4.0 ppm chlorine or 2.0-4.0 ppm bromine after performing steps 1-6 above.

9. Add 2.5 ounces (71 g) of sodium dichlor for every 100 gallons (378

Liters) of water. Refer to the table below for approximate water fill volume by model.

!

CAUTION: RISK OF PERSONAL INjURY OR SPA DAMAGE!

Never add chlorine tablets (trichlor) or acid to your hot tub for any reason! These chemical may damage components within your hot tub, burn or irritate your skin, create a rash, and void the manufacturer warranty for your spa.

Page 20

680 SERIES

Water volume by Model

Model

Average

Fill volume*

Sodium

Dichlor

Denali ..................................230 Gal ( 871 L) .......................... 6.0 oz.

Tacoma ................................147 Gal ( 557 L) .......................... 4.0 oz.

Burlington ............................350 Gal (1,325 L) .......................... 9.0 oz.

Hartford ...............................390 Gal (1,476 L) ........................ 10.0 oz.

Hawthorne ...........................430 Gal (1,628 L) .........................11.0 oz.

*Use average fill volume for chemical maintenance

10. Leave spa cover open during this step to allow excessive chemical vapors to exit spa, protecting plastic knobs and pillows on Burlington, Hartford, Hawthorne and

Tacoma models from chemical attack. If spa is indoors, open doors and windows for proper ventilation. Turn on all spa jets pumps for one hour, open all air controls. On

Burlington, Hartford and Hawthorne (Figure A) and Denali

(Figure B) models, place the Massage Selector or Diverter

Jet in their center “combo” position as shown (right).

Note: You will need to press the jets pump button(s) every

20 minutes since these functions have an automatic 20 minute time-out function that turns them off.

Massage Selector

B

Figure A

Figure B

Set all air controls to their full open counterclockwise position

!

WARNING:

BECAUSE OF THE RISK OF INHALING

CHEMICAL vAPORS.

• To decrease the risk of injury, drowning or entrapment,

• never leave your hot tub unattended for any reason while the cover is open and accessible, especially to small children and animals!

Precautions should be taken to minimize your exposure to chemical vapors (that could cause lung, brain, or skin damage).

11. Turn off power to the spa at the circuit breaker, then drain spa as

outlined in Section 11.2 (page 33).

12. Refill spa with clean tap water from garden hose until water covers all jets. (DO NOT OVERFILL!)

Page 21

680 SERIES

CAUTION: TO DECREASE BUILD UP ON COMPONENTS AND

MINIMIZE ACRYLIC DAMAGE.

Never fill with water from a water softener. If your water is extremely

“hard”, it is preferable to fill half-way with hard water and the rest of the way with softened water. Water that is too soft can be corrosive to metal components.

13. Consult your authorized Sundance dealer for chemical recommendations, then add chemicals to spa water to achieve a constant sanitizer reading within the levels recommended by the

Association of Pool and Spa Professionals/USA printed on the inside cover of this manual.

14. Turn on all jet pumps when adding chemicals to ensure proper mixing and leave your spa cover open until the sanitizer level falls below 4.0 ppm to protect plastic knobs and pillows from chemical attack.

!

WARNING:

RISK OF PERSONAL INjURY.

To decrease the risk of injury, entrapment or drowning, never leave your hot tub unattended for any reason, especially if while the cover is open and accessible to small children and animals!

To decrease the risk of contracting a waterborne illness

(e.g. an infection, bacteria or virus) and/or respiratory ailments, maintain water chemistry within 6 step parameters. If you or other bathers experience such a condition, discontinue use and seek immediate medical attention.

15. Establish a sanitizer reading between 3.0-4.0 ppm chlorine or

2.0- 4.0 ppm bromine, then allow the spa to set undisturbed for 8 hours. Retest water after 8 hours to determine if sanitizer levels are stable. If sanitizer levels are stable, your spa is ready for use.

To ensure healthy water conditions, always maintain a constant sanitizer reading within the levels recommended by the Association of Pool and Spa Professionals/USA printed on the inside cover of this manual. If sanitizer levels are not stable at this time, it will be necessary to repeat this procedure in its entirety (steps 1-15) until stable sanitizer readings are achieved.

16. After adequate sanitizer levels are achieved, close all spa air controls to maximize heat retention when spa is not in use.

Page 22

680 SERIES

8.0 Control Functions

8.1 Control Panel

A. LED Display: Can display current water temperature (default display), water temperature set point, selected filtration/heating mode, and error messages.

A

B

C D

E F G

B. Heat Indicator: Lit when heater is on.

2 Pump Panel Shown

C. Warmer ( ) Button: Increases water temperature set point.

D. Cooler ( ) Button: Decreases water temperature set point.

E. jets 1 Button: Turns jets pump #1 on and off. Press once for low speed; press a second time for high speed; press a third time to turn pump off.

F. jets 2 Button (Hartford and Hawthorne Models): Turns jets pump

#2 on and off. Press once for high speed; press a second time to turn pump off.

G. Light Button:

• Denali and Tacoma Models: Turns underwater light on in random

mode or in one of six solid colors. Refer to Section 9.3 (page 26) for

details.

Burlington, Hartford and Hawthorne Models with standard

Incandescent light system: Turns underwater light on and off. Refer

to Section 9.4 (page 26) for details.

Burlington, Hartford and Hawthorne Models with optional LED lighting system: Turns underwater light and top rim accent lights on in one of three random modes or one of seven solid colors. Refer to Section

9.5 (page 26) for details.

Operation Details

• Tem perature Adjustment: 65 to 104°F (18 to 40°C). Factory default setting is 100°F (38°C).

All lighting systems run for 1 hour then shut off.

• Jets 1/Jets 2 Button Ope ration: Jets run for 20 minutes after activated, then turn off automatically to conserve energy. Simply press either jets button to continue operation for an additional 20 minutes.

Page 23

680 SERIES

8.2 General Spa Features And Controls

12

2

3 6

4

5

8

4

3

8

8

9a

10

3

2

12

4

11

3

7

12

2

12

1 9b

2

12

Hartford model illustrated - Jet locations and features will vary by model. Specifications subject to change without notice.

1. Control Panel

2. Headrest Pillows (4 ea.)

3. Air Controls (4 ea.)

4. Cup Holders (6 ea.)

5. Massage Selector (1 ea.)

6. Waterfall

7. Waterfall control valve (1 ea.)

8. Suction Fittings & Filters (Filters protect massage selector from debris entrapment/damage. Filters require periodic cleaning. (3 ea .

)

9. Lighting System Options:

• Standard Underwater light system includes incandescent light (9a).

• Optional LED lighting system includes

LED footwell light (9a) and multiple

LED accents lights (9b).

10. Gravity Drain: Fitting functions as floor gravity drain, heater return and optional

CD ozone return.

11. Filter lid with four cup holders and two underlying filter cartridges.

• Spas without the circulation pump option utilize both filter cartridges for jets pump 1.

• Spas with the circulation pump option utilize one filter cartridge closest to waterfall valve (7) for jets pump 1 and the second cartridge for the 24 hour circulation pump.

12. Optional audio system speakers (4 ea.) and AM/FM/CD stereo deck (1 ea.) located on front spa skirt.

Page 24

680 SERIES

9.0 Operating Instructions

The spa control system has automatic functions that operate upon start-up and normal operation to protect the system. Upon power up, the readout displays the following information:

1. Control panel displays current software release (e.g. 3.57 or 5.57 depending on spa model), then;

2. Control panel displays “888” and all indicator LEDs are lit, permitting visual inspection of all display segments and indicator lights for proper operation.

3. After the initial start-up sequence ends, the

1.

2.

Spa with

Circulation

Pump Option

Spa without

Circulation

Pump Option actual water temperature is displayed. If water temperature at this time is less then

3.

the factory default temperature setting of

100°F (38°C) and the spa is set to either of the standard filtration/

heating modes (pages 30-31), the heater will turn on and run until the

water temperature rises to the factory setting, then turn off.

Note: It is common for the heater to turn on after the spa is first filled because tap water is often very cold.

9.1 Setting Water Temperature

The spa’s thermostat provides optimum control of water temperature. The temperature setpoint (set temperature) can be adjusted from 65°F to 104°F (18°C to 40°C). To raise the set temperature, press the WARMER ( ) button. To lower the set temperature, press the COOLER ( ) button. The first press of either button displays the set temperature.

To access the overtemp feature that allows the spa to reach 106°F (41°C) follow the steps below (Figure 1).

A. Press and hold the WARMER ( ) button then; C

A

B

1

Figure 1

B. Press and hold the jETS 1 ( ) button at the same time for 2 seconds. You will see the temperature rise to

106°F (41°C) on the LED display. To lower the temperature, press the COOLER ( ) button.

C. When the overtemp feature has been activated, the white decimal point after the last digit will flash on and off every second as an indicator for being in the overtemp mode.

Note: Once the temperature goes below 104°F (40°C) and you would like to raise the temperature to 106°F (41°C) again, you will have to repeat the steps above.

Page 25

680 SERIES

9.2 Activate Pumps

The jETS 1 button activates the jets pump 1. The first press activates in low speed, the second press activates high speed, and the third press shuts the pump off. The jETS 2

1 button (Hartford and Hawthorne models only) activates jets pump 2 which only operates in high speed. When manually activated, both pumps automatically turn off in 20 minutes.

2

9.3 SunGlow™ Light Operation (Denali and Tacoma Models)

The spa light offers 6 constant color variations and a unique random mode for enhanced spa enjoyment. Press the Light button once to turn the spa light on in Random mode, then repeatedly press the button to turn the light off or to select one of 6 constant colors as illustrated below.

Random OFF Red OFF Green OFF Blue

Off Teal OFF Violet OFF Orange OFF

You must press the LIGHT button within 5 seconds between each “off” or “color” selection to prevent it from resetting. Pressing the button after 5 seconds restarts the sequence in Random mode. This mode automatically changes the light color every 8 to 20 seconds.

Note: Any time the spa light is manually turned on, it will automatically turn off after approximately 1 hour. If you desire more light at this time, simply turn the light back on.

9.4 Standard Light Operation (Burlington, Hartford and

Hawthorne Models)

The light button activates the footwell light in the spa when pressed. Pressing the button turns the footwell light off. When manually activated, the footwell light will automatically turn off after one hour.

9.5 Optional Multi-Colored LED Light System Operation

(Burlington, Hartford and Hawthorne Models)

The multi-colored LED spa light offers seven constant color variations and three unique random modes for enhanced spa enjoyment. Press the light button once to activate the first light mode Random Fade, then continue pressing the button to either turn the light off or to select one of seven constant colors, random solid color mode or strobe mode as illustrated.

Page 26

680 SERIES

Press

Once

= RANDOM FADE

= off

= NEAR WHITE

= off

= LIGHT BLUE

= off

= VIOLET

= off

= DARK BLUE

= off

= LIME GREEN

= off

= DARK GREEN

= off

= RED

= off

= RANDOM SOLID

Lights display hunderds of colors in 5-6 second intervals.

Light Operation Tips:

You must press the light button within 3 seconds of any “off” condition or the light sequence will revert back to “Random

Fade” mode, when reactivated.

Any time the spa light is manually activated, it will remain on for 1 hour then automatically shut off.

Lights display different solid color every 5-6 seconds

= off

= STROBE

= off

Lights flash “strobe” in white color

9.6 Adjusting Individual jet Flow

The water flow through individual jets in your spa can be adjusted or turned off by rotating the outside jet ring. Many jets also offer an adjustable center nozzle that allows you to change the water discharge angle. Simply tilt the center nozzle in these jets to the desired angle to customize your personal massage.

Note: Always keep at least 6 adjustable jets open at all times to ensure proper filtration characteristics within spa.

Page 27

680 SERIES

9.7 Selecting Desired Massage Action

All models (except Tacoma) incorporate a massage selector valve or Diverter Jet that allows you to customize the massage and performance by diverting water between various jet systems within the spa. Simply turn valve to positions A, B or

C to divert water pressure to various jet groups.

Note: The valve is intended to operate in positions

A (Combo), B, or C for optimum performance. It is

B

A

C

A

Burlington, Hartford and Hawthorne models considered normal for sound levels within the valve to increase between these positions due to the large amounts of water flowing through it. For optimum filtration benefits, always leave this valve in position A when the spa is covered and select positions B or C for maximum jet performance during spa use.

B

C

Denali model

9.8 Air Controls

Certain jet systems have their own air control. Each control introduces air into the water lines that supply that specific jet group. Simply turn the air control selection to open or close. To minimize heat loss, all air controls should be closed when the spa is not in use.

Burlington, Hartford and Hawthorne models

Denali model

9.9 Optional Audio System

Burlington, Hartford and Hawthorne models equipped with the optional audio system offer enhanced spa enjoyment. These models include a high-quality AM/FM/CD stereo receiver with four high-quality marine speakers for unsurpassed sound quality and long-life. Refer to Section

21.0 (page 49) for complete stereo operation details.

Page 28

680 SERIES

10.0 Automatic Filtration Cycles

The control system activates a programmable “standard” or “economy” filtration cycle to remove debris from your spa. These cycles use the low speed pump, skimmer basket, and filter cartridge quickly clear “skim” the water of debris and minimize their “bathtub ring” affect. Apart from their filtration benefit, each mode also effects the operation of your spa’s heater.

Refer to Sections 10.1-10.3 below for additional information.

10.1 Standard Filtration/Heating Modes For Models Without

Circulation Pump Option

Standard filtration/heating modes (F1-F3) are typically selected by customers in cold climates where heat up times are extended due to lower ambient temperatures. In either of these modes, the water temperature is regulated by the set temperature, low-speed jets pump

1 and heater which turns on as needed. After the programmed set temperature is reached, the heater and low speed pump turn off, only to turn back on during a heat call or during the next programmed filtration/ heating cycle.

10.2 Standard Filtration/Heating Modes For Models With Circulation

Pump Option

Standard filtration/heating modes (F0-F3) are typically selected by customers in cold climates where heat up times are extended due to lower ambient temperatures. In either of these modes, the water temperature is regulated by the set temperature, 24 hour circulation pump and heater which turns on as needed. After the programmed set temperature is reached, the heater turns off and the circulation pump continues to operate 24 hours to filter and clean your spa.

10.3 Economy Filtration/Heating Modes (F4-F6)

Economy filtration/heating modes are typically selected by customers in warm climates where heat up times are minimized due to higher ambient temperatures. In these modes, the water temperature is regulated by the set temperature, low-speed pump, optional circulating pump and heater only while a programmed filtration/heating cycle is running.

Note: These modes consume less energy than standard modes F1-F3 outlined above.

10.4 Lock Modes (L1-L2)

These modes are designed for use during spa service or to prevent unauthorized use.

Page 29

680 SERIES

10.5 Selecting The Filtration/Heating Mode

Press and hold both control panel WARMER (

COOLER ( )

Then press either WARMER ( ) or COOLER ( ) button to select filtration/heating mode F1-F6 or lock modes L1-L2 on the following pages.

) and

buttons at the same time, then release.

10.6 Filtration Modes for Spas Without Circulation Pump Option

If your spa is equipped with the circulation pump option, disregard this

section and refer to page 31 for filter cycle programming details.

Standard Filtration/Heating Modes (F1-F3)

F1 4 hours of filtration/heating per day (one 2-hour cycle every

12 hours).

F2 6 hours of filtration/heating per day (one 2-hour cycle every

8 hours).

F3 8 hours of filtration/heating per day (one 2-hour cycle every

6 hours).

Economy Filtration/Heating Modes (F4-F6)

F4 4 hours of filtration/heating per day (one 2-hour cycle every

12 hours).

F5 6 hours of filtration/heating per day (one 2-hour cycle every

8 hours).

F6 8 hours of filtration/heating per day (one 2-hour cycle every

6 hours).

Lock Modes (L1-L2)

L1 Lock Out (disables all spa functions to permit filter cleaning).

L2 Lock Mode (disables the jets and light buttons to prevent unauthorized use of spa). Filtration/heating cycle will continue to operate as programmed in this mode. The temperature display flashes when this function is enable.

Example: the “F3” filtration/heating cycle was enabled prior to choosing lock mode. The spa continues to perform the “F3” cycle until lock mode is canceled, allowing another cycle to be selected.

Filter Cycle Setup Example

To set a time for the first filtration/heating cycle, simply turn power on to the spa two minutes prior to the desired time. Example: If you desire your first filtration/heating cycle to begin at 10:00 AM turn off power to the spa and turn it back on again at 9:58 AM.

Note: Start time is approximate and may vary slightly from day to day.

Page 30

680 SERIES

10.7 Filtration Modes for Spas With Circulation Pump Option

If your spa is not equipped with the circulation pump option, disregard

this section and refer to page 30 for filter cycle programming details.

Standard Filtration/Heating Modes (F0-F3)

(Heater automatically turns on during any heat call while in any Standard mode).

F0 5 minutes of filtration per day (one 5 minute “Blow-Out” cycle every 24 hours to purge all plumbing lines)

F1 1 hour of filtration per day (one 30-minute cycle every twelve hours); this is the factory default setting.

F2 1.5 hours of filtration per day (one 30-minute cycle every eight hours).

F3 2 hours of filtration per day (one 30-minute cycle every six hours).

Economy Filtration/Heating Modes (F4-F6)

(Heater can only turn on during an active filter cycle while in any economy mode).

F4 1 hour of filtration/heating per day (one 30-minute cycle every twelve hours).

F5 1.5 hours of filtration/heating per day (one 30-minute cycle every eight hours).

F6 2 hours of filtration/heating per day (one 30-minute cycle every six hours).

Lock Modes (L1-L2)

L1 Lock Out (disables all spa functions to permit filter cleaning).

L2 Lock Mode (disables the jets and light buttons to prevent unauthorized use of spa). Filtration/heating cycle will continue to operate as programmed in this mode. The temperature display flashes when this function is enable.

Example: the “F3” filtration/heating cycle was enabled prior to choosing lock mode. The spa continues to perform the “F3” cycle until lock mode is canceled, allowing another cycle to be selected.

Filter Cycle Setup Example

To set a time for the first filtration/heating cycle, simply turn power on to the spa two minutes prior to the desired time. Example: If you desire your first filtration/heating cycle to begin at 10:00 AM turn off power to the spa and turn it back on again at 9:58 AM.

Note: Start time is approximate and may vary slightly from day to day.

Page 31

680 SERIES

11.0 Spa Maintenance

Proper and regular maintenance of your spa will help it retain its beauty and performance. Your authorized Sundance dealer can supply you with all the information, supplies, and accessory products you will need to accomplish this.

DANGER:

RISK OF SEvERE INjURY OR DROWNING

BY ENTRAPMENT!

Keep hair, loose articles of clothing or hanging jewelry away from suction fittings, rotating jets or other moving components to avoid entrapment that could lead to drowning or severe injury.

Never use the spa unless all suction guards, filter, filter lid, or skimmer assembly are installed to prevent body and/or hair entrapment.

Never operate or use the spa if the filter, filter lid, or skimmer assembly are broken or any part of the skimmer assembly is missing.

Please contact your dealer or nearest service center for service.

The suction fittings and suction covers in this spa are sized to match the specific water flow created by the pump(s). If it is necessary to replace the suction fittings, suction covers or pump(s), be sure that the flow rates are compatible and are in

compliance with the VGB Safety Act page 2.

Never replace a suction fitting or suction cover with one rated less than the flow rate marked on the original suction fitting.

Using improper suction fittings or suction covers can create a body or hair suction entrapment hazard that may lead to drowning or severe injury.

Owners must alert all spa users to the potential risk of Hair,

Limb, Body, Evisceration (disembowelment), and Mechanical

Entrapment, page 6.

DANGER:

TURN POWER TO SPA OFF!

To Remove: Turn

Counterclockwise

To Install: Turn

Clockwise

TO DECREASE RISK OF DEATH, DROWNING,

OR ENTRAPMENT, NEvER OPERATE SPA

WHEN FILTER IS NOT PROPERLY INSTALLED

OR IF SKIMMER ASSEMBLY IS DAMAGED OR

ALTERED!

A. Burlington, Hartford and Hawthorne

Models:

Your spa is equipped with two filter cartridges

Cartridge 1 Cartridge 2 which are utilized as follows:

• Models equipped with the optional 24

Spa Filter Bay hour circulation pump use cartridge 1 for the circulation pump and cartridge 2 for jets pump 1.

Page 32

680 SERIES

• Spas not equipped with the optional 24 hour circulation pump use both filter cartridges for jets pump 1.

During spa use or an automatic filter cycle, water flows through the spa skimmer and into both polyester mesh filter cartridges to trap suspended particles and oils on their surface pleats. To ensure optimum performance, it is necessary to remove and clean both filter cartridges once a month or sooner depending on spa use and water quality.

B. Denali and Tacoma Models:

Your Sundance spa is equipped with a skimmer basket and filter cartridge located in the skimmer/filter well. Filtering is accomplished when the pump turns on in low speed to initiate water flow through the skimmer basket and polyester mesh filter cartridge. As this happens, suspended particles become trapped on the filter’s surface. To ensure optimum performance, it is necessary to remove and clean the skimmer basket once a week and filter cartridge once a month or sooner, depending on usage and water quality.

C. Cleaning Procedure (for All Models):

1. Turn off power to the spa at the home’s breaker panel or select

the L1 “Lock” mode (page 29) to disable all spa functions.

2. Remove the filter strainer lid assembly.

3. Remove the filter cartridge by rotating it counterclockwise to unthread it from the filter wall fitting, then lift it straight up to remove from filter well.

4. Using a garden hose with a high-pressure nozzle to rinse debris from the filter pleats beginning at the top and working your way downward.

Continue, one section at a time, until you have rinsed all of the filter’s pleats.

Periodically, the filter cartridge will need a more thorough cleaning to remove imbedded oils and minerals. For this, we suggest cleaning as above and then soaking the cartridge overnight in a plastic container filled with a solution of water and a specially formulated filter cleanser available from your authorized Sundance dealer. The average life expectancy of a Sundance filter cartridge is approximately two years with proper care and water quality maintenance. A replacement cartridge may be purchased from your dealer.

11.2 Draining and Refilling

About every 3 months, you will want to replace the spa’s water. The frequency depends on a number of variables including the amount of use, attention paid to water quality maintenance, etc. You will know it is time for a change when you cannot control sudsing and/or you can no longer get the normal feel or sparkle to the water even though the key water balance measurements are all within the proper parameters.

Page 33

680 SERIES

!

CAUTION! READ THIS BEFORE DRAINING: To prevent damage to the spa’s components, turn off power to the

spa at the circuit breaker before draining it. Do not turn the power back on until your spa has been refilled. There are certain precautions to keep in mind when draining your spa.

If it is extremely cold, and the spa is outdoors, freezing could occur in the lines or the equipment (see “WINTERIZING”,

page 36). On the other hand, if it is hot outdoors, do not leave

the spa’s surface exposed to direct sunlight.

To drain your spa, perform the following steps:

1. Turn off power to spa at breaker.

2. Locate and remove the synthetic cabinet door screws and door. The door is located directly below the control panel and is easily identified by it’s vertical cooling slots.

3. Locate drain hose line attached to 2 x 4 wood slat (Figure A) with tie wraps.

4. Cut tie wraps and pull drain hose from equipment area (Figure B).

5. Hold drain hose above water line (Figure B), then unthread drain cap (1) from hose using a counterclockwise rotation. Place hose on ground making sure to direct water away from spa.

6. Turn valve (2) clockwise to open drain (Figure C).

7. After spa has completely drained, reinstall drain cap on drain valve finger tight! DO

NOT OVERTIGHTEN! Close valve by turning clockwise to off position.

8. Place drain hose back inside the spa equipment bay.

9. Reinstall synthetic cabinet door and screws.

10. After refilling spa, turn on power and follow the

“Spa Fill Up Procedure” (page 18).

1

Figure A

2

Figure B

Figure C

11.3 Pillow Care (All Models Except Denali)

Remove and clean the headrest pillows as needed with soapy water using a cloth or soft-bristle brush. To maintain water resistance and luster, apply a quality vinyl conditioner once a month. Always remove the pillows when adding chemical shock treatment to the spa water. The pillows can be returned to the spa when the sanitizer reading drops below 4 ppm.

11.4 Cleaning The Spa Interior

To preserve the sheen of your spa’s surface, it is crucial that you avoid using abrasive cleaners or cleaners which have adverse chemical effect on the surface. If you are not certain as to the suitability of a particular

Page 34

680 SERIES cleanser, consult your authorized Sundance dealer. Regardless of the cleanser used, use extreme care to assure that no soap residue is left on the surface. This could cause severe sudsing when the spa is refilled.

11.5 Maintaining The Cover

Using the Sundance insulating spa cover anytime the spa is not in use will significantly reduce your operating costs, heat-up time and maintenance requirements. To prolong the life of the cover, handle it with care and clean it regularly. Below are the care instructions.

A. To Clean and Condition the vinyl Cover

1. Use a garden hose to loosen debris and dirt.

2. Using a large sponge or a soft bristle brush, use diluted or mild soap and scrub the vinyl top. Rinse clean and do not allow soap to dry on cover. Do not use soap on the underside of the cover.

3. Please check with your Sundance Spa Dealer for recommended cover care and conditioning products. Condition using non-petroleum based conditioners to keep the vinyl supple and threads/stitching from drying out. Do not use solvents, abrasive cleaners or strong detergents. Do not use products that contain silicone or alcohol.

B. Additional Care and Maintenance Instructions:

1. Debris can accumulate on the spa cover. Removal of snow or other debris will help to avoid breakage of the foam cores.

2. Be sure to lock the cover straps to secure the cover from unwanted or accidental entry.

3. Do not place heavy objects on the vinyl.

4. Do not walk, sit or stand on the cover.

5. Do not drag or use the flaps/skirt or the cover lock straps to remove the cover.

6. Use only recommended cover lift systems.

7. Use only chemicals and cleaners recommended by Sundance Spas.

8. Remember to keep spa covered when not in use. Maintaining proper water levels assures efficient operation and efficient electrical usage.

9. Do not expose your spa to the sun for extended periods of time as

UV rays can damage the interior surface.

10. Use caution when removing cover. Before removing cover, assure all locks have been released to avoid lock breakage and or cover strap damage.

Page 35

680 SERIES

11.6 Maintaining The Synthetic Cabinet

Your new spa’s synthetic cabinet requires little or no maintenance of any kind. To clean, simply wipe cabinet with a clean towel and mild soap solution.

CAUTION: Never spray cabinet with a garden hose for any reason since this action may induce an electrical short in the spa’s electrical equipment.

11.7 Winterizing

Your Sundance ® spa is designed to automatically protect itself against freezing when operating properly. During periods of severe freezing temperatures, you should check periodically to be certain that the electrical supply to the spa has not been interrupted. In extreme, bitter cold weather less than -20°F (-29°C), choose the F3 “Standard” filtration/

heating mode to prevent freezing (pages 30-31).

If you do not intend to use your spa, or if there is a prolonged power outage during periods of severe freezing temperatures, it is important that all water be removed from the spa and equipment to protect

against damage from freezing.

Expert winterization of your spa is highly recommended, contact your authorized Sundance dealer. In emergency situations, damage can be minimized by taking the following steps:

CAUTION: TURN OFF POWER TO HOT TUB!

1. Turn off power to the spa.

2. Follow the directions on page 33 for draining the spa.

3. Turn the massage/diverter selector(s) into the middle combo position

to allow the water in the plumbing lines to drain, see page 28.

4. Turn the waterfall valve to the open position to allow the water in the

plumbing lines to drain, see page 24.

5. As the water level drops below the seats, use whatever means necessary to get the water out of the recessed seating areas and into the footwell, such as a wet/dry vacuum.

6. When the water level ceases to drop, use whatever means available to remove any remaining water from the footwell, such as a wet/dry vacuum.

7. Remove the equipment-side cabinet panel and locate the drain plugs

in the front of the pump(s) (Figure A, page 16). Remove these plugs

to allow the water to drain out of the pumps and heater.

Note: Approximately one to two gallons will be released during this procedure. Use a wet/dry vacuum or other means to keep this from flooding the equipment compartment. Replace the pump drain plugs.

8. Re-install cabinet side panels and cover spa so that no casual moisture can enter into it.

Page 36

680 SERIES

Consult your authorized Sundance dealer if you have any questions regarding winter use or winterizing.

11.8 Restarting Your Spa in Cold Weather

If you want to start up your spa after it has sat empty for a time in freezing temperatures, be aware that the water remaining in certain sections of the piping may still be frozen. This situation will block water flow preventing the spa from operating properly and possibly damaging the equipment. We recommend you consult your authorized Sundance dealer for guidance before attempting to re-start your spa under these conditions.

12.0 Water Quality Maintenance

To decrease the risk of contracting a waterborne illness (e.g. an infection, bacteria or virus) and/or respiratory ailments, maintain water quality within specified limits. This will enhance your enjoyment and prolong the life of the hot tub’s equipment. Doing so requires regular attention because the water chemistry involved is a balance of several factors. Procrastination in regard to water maintenance will result in poor and potentially unhealthful conditions for soaking and even damage to your hot tub investment. For specific guidance on maintaining water quality, consult your Authorized

Sundance Spas dealer who can recommend appropriate chemical products for sanitizing and maintaining your hot tub.

!

WARNING:

FAILURE TO MAINTAIN WATER QUALITY

WILL:

• Increase risk of contracting a waterborne illness (e.g. an

• infection bacteria or virus) and/or respiratory ailments.

Damage the equipment, components and spa shell, which are not covered under the hot tub’s warranty.

CAUTION: Never store hot tub chemicals inside the hot tub’s equipment bay. The equipment bay may reach elevated temperatures, this is where high voltage electronic devices are located. This area is not intended for storage of any kind.

12.1 pH Control pH is a measure of relative acidity or alkalinity of water and is measured on a scale of 0 to 14. The midpoint of 7 is said to be neutral, above which is alkaline and below which is acidic. In spa water, it is very important to maintain a slightly alkaline condition of 7.4 to 7.6 pH. Problems become proportionately severe the further outside of this range the water gets.

A low pH will be corrosive to metals in the spa equipment. A high pH will cause minerals to deposit on the interior surface (scaling). In addition,

Page 37

680 SERIES the ability of the sanitation agents to keep the spa clean is severely affected as the pH moves beyond the ideal range. That is why almost all spa water test kits contain a measure for pH as well as sanitizer.

12.2 Sanitizing

To destroy bacteria and organic compounds in the spa water, a sanitizer must be used regularly. Chlorine and bromine are the two most popular sanitizers used to date. Many other additives are available for your spa.

Some are necessary to compensate for out-of-balance water; some aid in cosmetic water treatment and others simply alter the feel or smell of the water. Your authorized Sundance dealer can advise you on the use of these additives. When adding spa shock (chlorine or non-chlorine) or pH balancing chemicals activate the jets pump(s) and leave the spa cover open for a minimum of 20 minutes. By doing this you will allow excessive chemical vapors to exit the spa, protecting pillows and plastic knobs from chemical attack.

!

WARNING:

RISK OF PERSONAL INjURY, DROWNING

OR ENTRAPMENT!

Never leave your hot tub unattended for any reason while the cover is open and accessible, especially to small children and animals!

CAUTION: RISK OF PERSONAL INjURY OR SPA DAMAGE!

Never add chlorine tablets (trichlor) or acid to your hot tub for any reason! These chemical may damage components within your hot tub, burn or irritate your skin, create a rash and void the manufacturer warranty for your spa.

12.3 CD Ozone Water Maintenance System

This system is optional on North American models and standard equipment on export 50 Hz spa models. If your spa is equipped with the optional

Sundance CD Ozone water purification system you will find that your water stays fresh and clear with significantly less chemical sanitizer usage. You will also probably be able to go longer between complete spa drainings.

Page 38

680 SERIES

13.0 Error Conditions/Error Messages

Your spa has a self-diagnostic control system. The system will automatically display the following if a problem is detected.

13.1 Summer Logic (Spas With Circulation Pump

Option)

When the actual spa water temperature reaches up to 2°F

(1°C) above the set temperature, the spa goes into “summer logic.” The 24 hour circulation pump will turn off automatically to avoid adding additional heat to the water, eventually creating an overheat condition. This setting is not user-programmable.

Note: The summer logic does not take effect until the spa water temperature reaches 95°F (35°C). This condition is more likely in excessively hot weather. Remember, the spa’s ability to cool is directly affected by the ambient temperature. An excessively hot ambient temperature may prevent the spa from cooling down because it’s fully insulated construction is designed to retain heat and to minimize operating costs.

13.2 Panel displays SN1

Open sensor (heater is disabled) or shorted sensor

(spa is deactivated). The high-limit temperature sensor is not functioning. Your authorized Sundance dealer must repair this.

13.3 Panel displays SN2

Open or shorted sensor (heater disabled). The temperature sensor is not functioning. Your authorized Sundance dealer must repair this.

13.4 Panel Flashes FL1 or FL2 (Spas Without Circulation Pump

Option)

A flashing “FL1” display means the pressure switch is not closed when the jets pump 1 is activated. Proper water flow is inhibited or the pressure switch has malfunctioned. A flashing

“FL2” display means the pressure switch is malfunctioning closed. In either case, the heater is deactivated. To correct condition, perform to the following:

1. Verify water level is one inch below lowest pillow. Add water if necessary.

2. Check for clogged or excessively dirty filter cartridges (Section 11.1,

page 32).

3. Purge “air lock” from jets pump 1 by loosening the upper pump head

drain screw (Figure A, page 16) for a few seconds to release trapped

air, then retighten drain screw. FINGER TIGHT ONLY!

4. If problem persists, contact your authorized Sundance dealer.

Page 39

680 SERIES

13.5 Panel Flashes FL1 or FL2 (Spas With Circulation

Pump Option)

A flashing “FL1” display means the flow switch is malfunctioning open, the circulation pump filter cartridge 1 is excessively dirty or an “air lock” condition has occurred at the circulation pump intake. A flashing “FL2” display means the flow switch is malfunctioning closed. In either case, the spa heater will deactivate and jets pump #1 may also deactivate. To correct condition perform the following:

1. Verify water level is 1" below lowest pillow. Add water if necessary.

2. Check for clogged or excessively dirty filter cartridges (Section 11.1,

page 32).

3. Purge “air lock” from circulation pump intake by removing filter

cartridge 1 (page 32). Hold your garden hose over the filter cartridge

1 wall fitting (with grate) while using a rag as a seal around hose end.

Ask a helper to turn on water for 30 seconds, then turn off. Reinstall

filter cartridge 1 and check spa (Section 11.1, page 32).

4. If the circulation pump is not running, turn power off at the main breaker, then turn power back on. This will reset the circulation pump priming cycle. Once the pump is primed, the error should clear.

5. If problem persists, contact your authorized Sundance dealer.

13.6 Panel displays COL

Cool Condition - Temperature has dropped 20°F (11°C) below the current set temperature. The pump and heater have been activated to bring the temperature to within 15°F (8°C) of the set temperature. No corrective action is required.

Note: During cold periods, you may consider increasing the number of

filtration cycles (pages 30-31).

13.7 Panel Displays ICE

Freeze Protection - A potential freeze condition has been detected. No action is required. The pump and heater will operate to circulate and warm water through the plumbing spa is out of

danger. See “Winterizing” Section 11.7 for details (page 36).

13.8 Panel Displays OH

!

WARNING: RISK OF HYPERTHERMIA (OvER-

HEATING) CAUSING SEvERE INjURY, BURNS, OR

WELTS.

Water temperature is above acceptable limits. DO NOT ENTER SPA!

Water temperature has reached 112°F (44°C) and the low speed pump has activated to circulate water through heater.

Page 40

680 SERIES

13.9 Panel displays - - -

!

WARNING: RISK OF HYPERTHERMIA (OvER-

HEATING) CAUSING SEvERE INjURY, BURNS, OR

WELTS.

Water temperature is above acceptable limits. DO NOT ENTER SPA!

The safety “Watchdog” software has been triggered and the spa is deactivated. A problem has been detected which could cause damage to the spa or its components. Contact your authorized Sundance dealer.

14.0 Troubleshooting Procedures

In the event your spa is not working the way it should, please first review all the installation and operating instructions in this manual and check the message on the panel display. If you are still not satisfied it is working properly, please follow the appropriate troubleshooting instructions below.

Note: If any of the supply cords to the accessories are damaged, they must be replaced by authorized service personnel.

14.1 None of the Components Operate (e.g. Pump, Light)

Check the following when none of the spa components operate

(e.g. jets pumps or light):

1. Is there power to the spa?

2. Is the household circuit breaker tripped?

3. Call your authorized dealer.

14.2 Pump Does Not Operate but Light Does

Press the JETS 1 Button:

1. If no water movement is detected, make sure power is going to the spa and check the water level. If it does not solve the problem, contact your authorized Sundance dealer.

2. The main pump operates but no water flows to jets. Pump may not be properly primed. This can happen after the spa is drained and refilled.

A. Press the JETS 1 button several times, never leaving the motor on for more than 5 to 10 seconds at a time. Turn power off and let the air out removing the filter cartridge. Refer to Section 11.1

(page 32). Make certain you reinstall the filter cartridge before

turning on spa power and restarting the jets pump.

B. If your spa is equipped with a massage/diverter selector:

1.) Turn off the power to the spa.

Page 41

680 SERIES

2.) Remove the handle from the massage selector supplied by the pump you are priming.

3.) Loosen the massage selector’s cap slightly

(counterclockwise), listening for the air to seep out.

4.) Tighten the cap finger tight, replace the handle, and turn the spa’s power back on.

14.3 Poor jet Action

1. Press the JETS 1 button to make certain the pump #1 is on.

2. Open all air control to the “on” position.

3. Check for dirty filter. Clean, if necessary.

4. Make sure jets are all the way open.

14.4 Water is Too Hot

Reduce thermostat setting.

14.5 No Heat

1. Check thermostat setting.

2. Keep the spa cover in place while heating.

3. Check the settings to see if your spa is in economy filtration/heating

mode (pages 30-31).

Should checking the above steps fail to correct the problem, please call your dealer so that they may arrange service.

We build the best spas in the industry. Nonetheless, we are always striving to improve the quality and features of our products. Your input as a Sundance spa owner is a cherished part of this process. If you have any comments or suggestions, or if you wish to be informed on any new products for your spa, please write to us.

CONGRATULATIONS on your good taste and welcome to the happiest and most relaxed family in the world!

Page 42

680 SERIES

15.0 North American Denali/Tacoma Convertible Circuit

Diagram (60 Hz)

This wiring diagram is used for all North American Denali/Tacoma

120/240 VAC (60 Hz) convertible power models.

J1 Logic Jumper Settings (Factory Defaults Shown)

JP1 1-2 ON = 30A Logic (4-wire 120/240 VAC operation only)

JP1 1-2 OFF = 40A Logic (4-wire 120/240 VAC operation only)

JP1 7-8 ON = °C Temperature Display

JP1 7-8 OFF = °F Temperature Display

J20

O3

J21

Spa Light

Optional

Ozonator

BLK

J12

J14

4

2

8

6

J1

3

1

7

5

BLK

J16

Control

Panel

J2

J3

Temperature Sensor

Hi-limit/Freeze Sensor

Pressure Switch

Transformer

120 VAC

WHT

J11

F1

F1

20A

250V

SC-20

Plug-in

GFCI

Cord (US

Models

Only) OR

Hard

Wire GRN

TB1

WHT

BLK

BLK

1

2

BLK

3

WHT

J15

J13

J5

K5 K7

J6

WHT

J17

Heater IN

J7 J8

BLK

Main Pump

WHT

LO HI

RED

RED

BLK

WHT

RED

*

K8

Heater OUT

J9 J10

RED BLK

This device complies with Part 15 of the

FCC rules. Operation is subject to the following two conditions:

1. This device may not cause harmful interference.

2. This device must accept any inteference received including interference that may cause undesired operation.

Heater

1.0 kW @ 120 VAC (3-wire connection)

4.0 kW @ 240 VAC (4-wire connection)

Standard 3-Wire 120 VAC Connection (60 Hz, 1 Phase, 15A Service)

Use copper conductors ONLY. Wire size must be appropriate per NEC and/or local codes.

WARNING, ELECTRICAL SHOCK HAZARD EXISTS! Always remove power to spa before wiring and/or configuring the circuit board

To circuit board

Hard

Wire

Only

GRN

TB1

WHT

BLK

WHT

1

2

RED

*

BLK

RED 3

RED

*

Optional 4-Wire 240/120 VAC Convertible Heater Connection

1. Remove and discard the factory installed GFCI Cord.

2. Move RED * wire from TB1 position #1 to TB1 position #3 as shown below.

3. Permanently connect to the power supply. Use copper conductors ONLY.

Wire size must be appropriate per NEC and/or local codes.

4. If hot tub is to be operated on 30A service, make sure the jumper provided

at location JP1 #1&2 on the circuit board is installed. If hot tub is to be

operated on 40A service, remove the jumper JP1 #1&2 on the circuit board.

Page 43

680 SERIES

16.0 North American Burlington Models (60 Hz)

This wiring diagram is used for all North American Burlington models with or without the circulation pump option.

Heater 5.5 kW 240 V

Page 44

Circuit Board diagram shown with circulation pump option.

680 SERIES

17.0 North American Hartford and Hawthorne Models

(60 Hz)

This wiring diagram is used for all North American Hartford and

Hawthorne with or without the circulation pump option.

3 1

4 2

This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1.

BLK J5 F1 30A, 250V SC-30

Heater 5.5 kW 240 V

Optional Stereo

Standard Footwell Light

Circ. Pump

Circuit Board diagram shown with circulation pump option.

Page 45

680 SERIES

18.0 Export Denali/Tacoma Circuit Diagram (50 Hz)

This wiring diagram is used for all Export Denali/Tacoma models.

THERM SWITCH

Heater 2.7kW @ 230 V

7 5 3 1

8 6 4 2

J1 Logic Jumper Settings JP1 1-2 ON = 20A

Standard Ozonator

F1 20A 250V SC-20

GROUND

Hard Wire Only

Page 46

680 SERIES

19.0 Export Burlington Circuit Diagram (50 Hz)

This wiring diagram is used for all Export Burlington models with or without the circulation pump option.

Heater 2.7 kW @ 230 V

3 1

4 2

BRN J5

F1 20A, 250V SC-20

Optional LED Lighting System DCU Standard Footwell Light

Circ. Pump

Circuit Board diagram shown with circulation pump option.

Page 47

680 SERIES

20.0 Export Hartford and Hawthorne Circuit Diagram

(50 Hz)

This wiring diagram is used for all Export Hartford and Hawthorne models with or without the circulation pump option.

Heater 2.7 kW @ 230 V

Page 48 Circuit Board diagram shown with circulation pump option.

680 SERIES

21.0 Optional Audio Receiver Functions (Burlington,

Hartford and Hawthorne Models Only)

21.1 Audio Receiver Control Functions

10 11 12 13 14 2 22 7 21 3 5

SE

AR CH

BAND SUBW

2

ZONE

XBAS AS-PS

SAT INFO

TOP MENU

AUDIO

ENTER

MODE

AQ-CD-3

MULTI-

ENVIRONMENT

PLAYER

INT RPT RDM

15 16 17 18 19 20 6 8 4 1 9

Models equipped with the stereo option only:

To start enjoying your new Audio Receiver, please read the following operation instructions in their entirety.

1. Power Button: Press PWR (Power) to turn deck on or off.

2. Open Button: Press Open to flip down the front access panel for CD access. Gently insert CD into slot (DO NOT FORCE!) Make sure to

• close the front panel to prevent damage to the unit.

Eject Button (Not Illustrated): After releasing the front panel

, press the Eject button located to the left of CD slot to eject the CD. The unit does not have to be on to eject the CD.

Reset button (Not Illustrated): After releasing the front panel, use a pencil or any nonmetallic object to press and hold the reset button for five seconds to reset the main unit and the unit will return to the factory default settings.

Note: Never insert a wet or moist CD since it may damage the mechanism and void the manufacturer warranty.

3. Top Button: Has no function.

4. Mute Button: Press Mute to mute audio output. The word “Mute” flashes on the display panel. Press again to return to previous volume level.

Page 49

680 SERIES

10 11 12 13 14

SE

AR CH

BAND SUBW

2

ZONE

XBAS AS-PS

SAT INFO

2 22 7 21 3 5

TOP MENU

AUDIO

ENTER

MODE

AQ-CD-3

8 4

MULTI-

ENVIRONMENT

PLAYER

INT RPT RDM

15 16 17 18 19 20 6 1 9

5. Menu Function List Button: Press Menu to navigate through the list of stereo performance functions. Steps to access menu items:

A. To access the MENU press the Menu button < 3 seconds.

B. “MENU” will be displayed for 2 seconds, and then “CONTRAST” will appear on the display.

C. To navigate through the menus use the ( ) or ( ) buttons or press the MENU button repeatedly.

D. To adjust the selected menu item, press the VOLUME Up (7) or

Down (8) buttons.

E. After the selected menu item(s) has been changed and no other buttons have been pressed within the 5 second time-out, the unit will resume to the previous operation.

Contrast : “CONTRAST 5” will be displayed by default. The user now has 5 seconds to press the VOLUME Up or Down buttons to adjust from 0 – 10.

Dimmer : The dimmer feature of the display is set to “DIMMER High” by default. Use the Volume Up or Down buttons to adjust the Dimmer level between High or Low.

• Distant/Local: “Distant” is the default setting. User now has 5 seconds to adjust with the VOLUME Up or Down buttons from

“Distant” (a broader range of signals) to “Local” (only strong local stations). This feature is used to designate the strength of the signals at which the radio will stop during automatic tuning.

Page 50

680 SERIES

• Area: “USA” is the default setting. User now has 5 seconds to select

“USA, “LATIN”, “EUROPE” or “ORIT” by pressing the VOLUME Up or

Down buttons.

Note: “LATIN” and “ORIT” are not used.

Interamp On/Off: Feature is not used.

Programmable Turn-on volume: “VOL PGM 12” is the default setting. User now has 5 seconds use the VOLUME Up or Down buttons to program the turn on volume.

• Beep Tone: “ON” is the default setting. User now has 5 seconds to adjust by pressing the VOLUME Up or Down buttons from “ON” to

“OFF”.

6. Audio/Enter Button: Press Audio/Enter to navigate through the stereo sound functions. Short press “AUDIO“ button to access the audio menu. User can navigate thru the audio menu items by pressing the “AUDIO” button repeatedly, or by pressing the Tuning

Up (21) or Tuning Down Button (22). Once the desired menu item appears on the display, adjust that option by using the Volume Up (7) or Down button (8) within 5 seconds. The unit will automatically exit the Audio Menu after five seconds of inactivity.

• vOLUME (volume Level) : User has 5 seconds to use the Volume button to adjust the desire volume level, the volume level will be shown on the LCD display ranging from 00 (lowest) to 46 (highest).

• SUBWOOFER (Sub-woofer Level) : User has 5 seconds to use the

Volume Up or Down button to adjust the Sub-woofer lever from “00” to “12”.

Note: The Sub-woofer level control is only applicable if the unit is equipped with the optional subwoofer line out, and only if the unit is connected to an optional sub-woofer speaker. The Sub-woofer level control option will only appear in the Audio Menu if the “Sub-woofer” function is activated “ON” by pressing the “Sub-W” button on control panel.

• SUB-W LPF (Sub-woofer Low Pass Filter) : User has 5 seconds to use the Volume Up or Down button to select the 4 different Low Pass filters Flat, 80 Hz, 120 Hz or 160 Hz.

Note: The Sub-woofer LPF control is only applicable if the unit is equipped with the optional subwoofer line out, and only if the unit is connected to an optional sub-woofer speaker. The Sub-woofer LPF option will only appear in the Audio Menu if the “Sub-woofer” function is activated by pressing the “Sub-W” button on control panel.

Page 51

680 SERIES

10 11 12 13 14

SE

AR CH

BAND SUBW

2

ZONE

XBAS AS-PS

SAT INFO

2 22 7 21 3 5

TOP MENU

AUDIO

ENTER

MODE

AQ-CD-3

MULTI-

ENVIRONMENT

PLAYER

INT RPT RDM

15 16 17 18 19 20 6 8 4 1 9

• iX-BASS (iX-Bass Level) : User has 5 seconds to use the Volume Up or

Down button to select the 3 different Bass Boost level: Low, Mid, or High.

BASS (Bass Level) : User has 5 seconds to use the Volume Up or

Down button to adjust the desired Bass level range from -6 to +6.

BASS -CFQ (Bass Center Frequency) : User has 5 seconds to use the Volume Up or Down button to adjust the desired Bass Center

Frequency to 60 Hz, 80 Hz, 100 Hz, or 200 Hz.

BASS-Q: (Bass Quality Factor) : User has 5 seconds to use the

Volume Up or Down button to adjust the desired Bass Quality Factor to 2N, 1N, 1W or 2W. See Figure 1.

Shows the Bass Quality factor (Curve characteristics) of each step

15.0

12.5

10.0

Level

(dB)

7.5

5.0

2.5

0.0

10

2W

1W

2N

1N

100

Frequency (Hz)

1.0K

10.0K

Figure 1

MIDDLE (Middle Level) : User has 5 seconds to use the Volume Up or

Down button to adjust the desired Middle level range from -6 to +6.

MID-CFQ (Middle Cent er Frequency): User has 5 seconds to use the Volume Up or Down button to adjust the desired Middle Range

Center Frequency to 500 Hz, 1 KHz, 1.5 KHz, or 2.5 KHz.

Page 52

680 SERIES

MIDDLE-Q (Middle Quality Factor) : User has 5 seconds to use the

Volume Up or Down button to adjust the desired Middle Quality

Factor to 2N, 1N, 1W or 2W. See Figure 2.

Shows the Middle Quality factor (Curve characteristics) of each step

15

10

Level

(dB)

5

0

10 100

Frequency (Hz)

1.10³

1N

2N

1W

2W

1.10

4 1.10

5

Figure 2

• TREBLE (Treble Level) : User has 5 seconds to use the Volume Up or Down button to adjust the desired Treble level range from -6 to +6.

• TRE-CFQ (Treble Center Frequency) : User has 5 seconds to use the Volume Up or Down button to adjust the desired Treble center frequency to 10 KHz, 12.5 KHz, 15 KHz, or 17.5 KHz.

• BALANCE : User has 5 seconds to use the Volume Up or Down button to adjust the Balance between the right and left speakers from

R12 (full right) to L12 (full left). “C00” represents an equal balance between the right and left speakers.

• FADER: User has 5 seconds to use Volume Up or Down button to adjust the Fader between the front and rear speakers from R12 (full rear) to F12 (full front). “C00” represents an equal balance between the front and rear speakers.

7. volume Up Button: Press + (Volume Up) to increase the volume level. The volume level is shown on the display panel, ranging from 0 to 46.

8.

volume Down Button: Press - (Volume Down) to decrease the volume level. The volume level is shown on the display panel, ranging from 46 to 0.

9. Mode Button: Short press the Mode button to change input from XM

Tuner (not used), CD, AUX, or Tuner. The mode selection is shown on the display panel.

Page 53

680 SERIES

10 11 12 13 14

SE

AR CH

BAND SUBW

2

ZONE

XBAS AS-PS

SAT INFO

2 22 7 21 3 5

TOP MENU

AUDIO

ENTER

MODE

AQ-CD-3

MULTI-

ENVIRONMENT

PLAYER

INT RPT RDM

15 16 17 18 19 20 6 8 4 1 9

10. Band Button: Press Band to change between FM1, FM2, FM3,

AM1, or AM2 bands.

11. Sub-Woofer (SUBW) Button: Press the SUB-W button to activate the Sub-woofer function On, and “Sub-woofer” will appear on the

LCD display for 3 seconds. Press the SUB-W button again to turn off the Sub-woofer function.

12. 2 Zone Button: The feature is not used.

13. iX-Bass Button (XBAS) Button: Press the iX-BASS button to turn on the iX-BASS function, and “iX-BASS” will appear in the LCD display for 3 seconds. Press the iX-BASS button again to turn off the iX-Bass function.

14. AS/PS (Automatically Store/Preset Scan) Button: While in seek mode the stereo unit will automatically select 6 strong stations and

• store them in the current band. Select a band (if needed).

Preset Scan:

Scan stations stored in the current band. Select a band, press AS/PS button for less than 3 seconds. The unit will pause for ten seconds at each preset station. Press AS/PS button again to stop scanning when the desired station is reached.

Stereo: The unit will automatically pick up a stereo signal when available. When in stereo mode, the ST icon appears in the display.

When no stereo signal is available, the unit will automatically revert to mono operation, and no icon will be displayed.

15. Preset 1/Pause Play Button: In Tuner mode, any station can be stored as preset 1 by pressing and holding this button for 2 seconds, after the desired station is selected. To recall the station preset, simply press and release this button. In CD mode, pressing this button will pause or play the CD. When inserting a CD make sure the label side is facing up.

Page 54

680 SERIES

16. Preset 2/INT Button: In Tuner mode, any station can be stored as preset 2 by simply pressing and holding this button for 2 seconds, after the desired station is selected. To recall the station preset, simply press and release this button. In CD mode, pressing this button will preview each song on the disc for about 10 seconds. Press again to turn off this feature or once the desired track is reached.

17. Preset 3/RPT Button: In Tuner mode, any station can be stored as preset 3 by simply pressing and holding this button for several seconds, after the desired station is selected. To recall the station preset, simply press and release this button. In CD mode, pressing this button will play a song repeatedly. Press again to turn off this feature.

18.

Preset 4/RDM Button: In Tuner mode, any station can be stored as preset 4 by simply pressing and holding this button for 2 seconds, after the desired station is selected. To recall the station preset, simply press and release this button. In CD mode, press this button to randomly play song tracks. Press again to turn off this feature.

19.

Preset 5/DN Button: In Tuner mode, any station can be stored as preset 5 by simply pressing and holding this button for 2 seconds, after the desired station is selected. To recall the station preset, simply press and release this button. In CD mode, this button will browse the folders on CD-R and CD-RW discs.

20.

Preset 6/UP Button: In Tuner mode, any station can be stored as preset 6 by simply pressing and holding this button for 2 seconds, after the desired station is selected. To recall the station preset, simply press and release this button. In CD mode, this button will browse the folders on CD-R and CD-RW discs.

21.

Tuning Up Button: Press and hold Track Up for more than 3 seconds to manually adjust station frequency up, Auto Seek is shown on the display panel. Short press Track Up to scan/seek for next higher station, Manual Seek is shown on the display panel.

Scan mode stops as soon as a strong station is found. In CD mode, pressing this button will advance the CD up to the next track, the track number is shown on the display panel. Simply press and hold the button to fast forward through a track(s). CD play starts when the button is released.

Page 55

680 SERIES

22.

Tuning Down Button: Press and hold Track Down for more than

3 seconds to manually adjust station frequency down. Press Track

Down to scan/seek for next lower station. Scan mode stops as soon as a strong station is found. In CD mode, pressing this button will advance the CD down to the previous track, the track number is shown on the display panel. Simply press and hold the button to rewind through a track. CD play starts when the button is released.

23.

Displaying information: When a retail music CD is inserted, the disc will begin to play. The following information will be displayed: CD track no./Playtime

When a CD containing MP3 files is inserted, the display will change modes as follows:

Track no./Playtime

Folder name

File name

Song name

Artist’s name

Album name

The system can only display the first 8 letters of ID3 tags. If the recorded information is longer than 8 letters, text will scroll to the left once, then the 8 first letters will be displayed. If specific info has not been recorded on an MP3 disc, NO FOLD, NO TRK, NO TLT, NO

ALBM, NO ART will display.

24.

Playback Order of CD with MP3 Files:

A directory that does not include an MP3 file is skipped.

We recommend that you make no more than two levels for each disc.

Maximum number of folders: 255

Maximum number of folder levels: 8

Maximum number of characters for MP3 file name and folder name: 32

Sampling frequency: (32 kHz 44.1 kHz for WMA) and (16 kHz, 22.05 kHz,

24 kHz, 32 kHz, 44.1 kHz, 48kHz for MP3)

Bit rates: 32-320 Kbps

MP3 decoding format: MPEG 1, 2 & 2.5 Audio Layer 3

Folder names and file names can be displayed with up to 11 characters.

The characters A-Z, 0-9 can be displayed on this unit, other characters may not be displayed correctly.

ID3 tag is supported.

Page 56

680 SERIES

25. Reading MP3 files from a disc: When a disc containing MP3 data is loaded, the unit checks all the data on the disc. If the disc contains numerous folders with many levels or non-MP3/WMA files, it takes a longer time to start playback. In addition, it may take time for the unit to move to the next MP3 file and the fast forward function may not be performed smoothly. Loading such a media may produce loud noise and cause damage to the speakers. When selected to play, files and folders are accessed in order in which they were written by the CD writer. Therefore, the playing order may not be the same as the order in which they are expected. For example, a disc with the following folder/file hierarchy is subject to folder select, file select and play back

order as illustrated on page 58.

Note: Do not attempt to play a media containing a non-MP3/WMA file with the MP3/WMA extension or a media containing non MP3/WMA files.

21.2 Stereo Audio Receiver Specifications

Tuner

FM tuning Range ..............................................................87.5-107.9 MHz

FM Signal-to-Noise ...........................................................................80 dB

Stereo Separation.............................................................................45 dB

Capture Ratio ..................................................................................2.0 dB

AM tuning Range ................................................................530.1-710 kHz

Usable Sensitivity (IEC Standard) ................................ 22.5/27.0 (µv/dBf)

General

Power ................................................................................DC 11.5 -14.4V

Pre Output Voltage ................................................................................5V

Current Consumption ....................................................................... < 15A

Stand-By-Mode .................................................................................. < 1A

Maximum Mounting Angle ........................................... 30° from horizontal

Fuse...................................................................... 15-Amp Mini ATM Type

Page 57

680 SERIES

21.3 CD/MP3/WMA folder/file hierarchy

When selected for play, folder search, file search or folder select, files and folders are accessed in the order in which they were written.

Because of this, the order in which they are expected to be played may not match the order in which they are actually played. For example, a media with the following folder/file hierarchy is subject to folder search, file search or folder select as shown below. An outline of a media with

MP3/WMA is shown below. Subfolders are shown as folders in the folder currently selected.

Level 2 Level 3 Level 4

ROOT

Level 1

01

 NOT DISPLAY

001.MP3

002.MP3

003.MP3

004.MP3

04

05

009.MP3

010.MP3

011.MP3

Folder File

• The equipment assigns folder numbers. The user cannot assign folder numbers.

 It is not possible to check folders that do not include MP3/

WMA files. (These folders will be skipped without displaying the folder number and name)

012.MP3

013.MP3

014.MP3

06

015.MP3

016.MP3

08

02

07

019.MP3

020.MP3

 NOT DISPLAY

017.MP3

018.MP3

 NOT DISPLAY

09

005.MP3

03

021.MP3

022.MP3

023.MP3

006.MP3

007.MP3

008.MP3

 NOT DISPLAY

Page 58

680 SERIES

A. CD/MP3/WMA File/folder play

1. There are three different play methods as following:

• Press the M2 button more than 3 seconds during playing an MP3/

WMA disc for “Intro play” for all files of the current folder. Intro play should restart from the first song of the current folder, after all files in the current files have been intro-played. To disable current folder

“Intro play”, long press M2 button more than 3 seconds.

Press the M2 button less than 3 seconds is “Intro play” to all files on the disc. Intro play should re-start at the very first file of the disc after all files in the disc has been intro played. To disable all files “Intro play”, press M2 button less than 3 seconds.

2. File/Folder Repeat play :

• Press the M3 button more than 3 seconds during playing MP3/WMA

• disc for “repeat play” for all files of the current folder and keep on repeat playing the current folder until “repeat play” is disabled. To disable current folder “repeat play”, long press M3 button more than 3 seconds.

Press the M3 button less than 3 seconds to “repeat play” the current file and keep on repeat playing the current file until the “repeat play” is disabled. To disable current file “repeat play”, press M3 button less than 3 seconds.

3. File/Folder Random play:

• Press M4 button more than 3 seconds during playing MP3/WMA disc to

“random play” for all files of the current folder. To disable current folder

“random play”, long press M4 button more than 3 seconds.

Press M4 button less than 3 seconds is “random play” to all files on the disc. To disable all file “random play”, press M4 button less than 3 seconds.

B. CD/MP3/WMA File or Folder Search

1. Folder/Files Navigate Searching

• Press the BAND button. The LCD will display “Navigate”, and the illumination around the select knob will blink. Rotate the knob to navigate through all folders and sub-folders on the disc. The folder names will be displayed on the LCD. Press the select knob for more than three seconds to play the first file in the folder. Press the select knob for less than three seconds to access the sub-folders or files.

Rotate the select knob to navigate, then press the select knob to confirm and begin file play. During navigation search, press AS/PS or rotate the select knob counter-clockwise to move back to the last upper level of a folder.

Page 59

680 SERIES

C. ID3 information display

• For any MP3/WMA file recording with ID3 Tag information. The

ID3 information such like Album title, Track title, Artist Title will be displayed and automatic scrolling through the LCD while the file is playing. User also allows pressing the AS/PS button repeatedly to view the ID3 tag information manually.

ICON DESCRIPTION

FOLDER ICON

FILE ICON

TRACK ICON

ARTIST ICON

ALBUM ICON

21.4 Stereo Audio Receiver Troubleshooting

Before going through the check list, check wiring connection. If any of the problems persist after check list has been made, consult your nearest service dealer.

Symptom

No power

Cause

The fuse is blown

Solution

Replace the fuse

Disc cannot be loaded or ejected

Presence of CD disc inside the player

Inserting the disc in reverse direction

Compact disc is extremely dirty or defective disc

Remove the disc in the player, then put a new one

Insert the compact disc with the label facing upward

Clean the disc or try to play a new one

No sound

Condensation

Volume is in minimum

Wiring is not properly connected

Leave the player to off for an hour or so, then try again

Adjust volume to a desired level

Check wiring connection

Page 60

The operation keys do not work

Sound skips.

The radio does not work. The radio station automatic selection does not work.

ERROR

Disc Error

The built-in microcomputer is not operating properly due to noise

The installation angle is more than 30 degrees

The disc is extremely dirt or defective disc

The antenna cable is not connected

The signals are too weak

Mechanism Error

Maybe disc dirty/disc scratched/disc upside down

680 SERIES

Press the RESET button. Front panel is not properly fixed into its place

Adjust the installation angle to less than 30 degrees

Clean the compact disc. Then try to play a new one

Insert the antenna cable firmly

Select a station manually

Press the eject button to correct the problem. If the error code does not disappear, consult your nearest service dealer

Replace the disc

Page 61

680 SERIES

Page 62

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement

Table of contents