Rack Mount Distribution Amplifiers, with Power Doubled Hybrid Output 1

POWER

INPUT MONITOR

-30 dB

GAIN

MIN. MAX.

SLOPE

DAR DISTRIBUTION AMPLIFIER

OUTPUT MONITOR

-30 dB

MIN. FLAT

F1 F2 F3 F4 F5

DESCRIPTION

The R.L. DRAKE models DAR8642, DAR8633, DAR8618,

DAR7542, and DAR7533, are broadband distribution amplifiers designed for indoor headend use in both residential and commercial buildings where RF signal distribution in the frequency range of 54 to 860 MHz is required. Each model, except the DAR8618, incorporates a push-pull hybrid input preamp and a power doubled hybrid output amplifier to provide a very low distortion signal for launch amp applications in the output of an SMATV or CATV headend. The Gain and Slope controls both have a range of

10 dB minimum and operate between the preamp hybrid and the output hybrid to maintain a low noise figure over a wide range of gain and slope settings. Only the DAR8618 has a power doubled output hybrid with no input preamp and no adjustable gain and slope controls. All models have a provision for optional fixed input attenuators and equalizers.

Double-sided, plated through hole, glass epoxy, printed circuit boards, and SMT are used for low losses and maximum reliability.

All DAR models include a built-in diplexer filter. This allows the return path energy that is present at the output port of the DAR to be separated from the DAR output and passed to the return path output port.

Input and output test connectors are provided for convenient monitoring of the signal path. The amplifier circuitry is designed for maximum stability, low distortion, low noise figure, and is protected in a rugged aluminum housing.

- The unit operates from a nominal 115 VAC, 60 Hz input.

- Input equalizer and fixed attenuator options are available.

F1 - POWER LED

This indicator illuminates when power is supplied to the unit.

F2 - INPUT MONITOR

This connector may be used to monitor input to the DAR.

The levels will be 30 dB below the input levels at R3.

F3 - GAIN*

Adjusts the amplifier interstage attenuator.

F4 - SLOPE*

Adjusts the slope of the output signal.

F5 - OUTPUT MONITOR

This connector may be used to monitor the output of the

DAR. Levels will be 30 dB below those present at R2.

R2 must be terminated in 75 Ohms for an accurate reading.

* Not present on models with gain below 20 dB.

2 Rear Panel Connections

RETURN PATH

OUTPUT

RF OUTPUT

RF INPUT FUSE

1/2 A , 250 V SLO - BLO

FUSE

115 VAC , 60 Hz

40 WATTS

R1 R2 R3 R4 R5

R1 - RETURN PATH OUTPUT

Any return path signals from 5 to 42 MHz that are present at

R2 will be passed to this port.

R2 - RF OUTPUT

This is the RF output for CATV distribution and is the amplified output of channels that are input to port R3 from

54 MHz and higher. At this port, any return path channels from 5 to 42 MHz will be passed at unity gain to port R1.

R3 - RF INPUT

This connector accepts the RF input from a headend combiner output, 54 MHz and higher.

R4 - FUSE

If necessary, replace this fuse only with a fuse of the same indicated rating.

R5 - AC LINE CORD

Connect this line cord to a 115 V / 60 Hz AC power source.

Installation 3

INSTALLATION

1) Unpack the distribution amplifier.

2) Mount the amplifier in the desired location in the rack. Be sure to leave at least one open rack space above and below the amp to allow proper ventillation.

3) Connect input and output cables to the amplifier.

4) Plug the power line cord into a 115 VAC/60 Hz power source.

5) Preset slope control fully clockwise.

6) While monitoring the output levels at the Output Monitor

-30 dB test port, adjust the Gain control for desired output at the high end of the band. Then monitor the lowest channel and adjust slope control to equalize this channel to the desired level (usually equal to but not higher than the high end of the band). Since there can be a slight interaction between the slope and gain settings, it is advised to repeat this step a few times to ensure the desired levels are attained.

NOTE: The -30 dB input and output test ports can be used to monitor input and output levels. These are only accurate when the load is connected to the amplifier output and power is on.

A WORD CONCERNING INPUT LEVELS

It is important to keep the input level to the amplifier within an optimum range. If the level is too high, higher nonlinear distortion will result and if the level becomes too low, C/N might be less than desired. As a general rule, stay within the optimum input level range listed in the specifications.

The listed levels assume a fully loaded channel complement.

Higher levels may be used if the channel loading is less.

In general, install a fixed input attenuator if required to set the highest frequency channels in the input to within the optimum range. Then set the amplifier gain to achieve the desired output level, not to exceed the maximum output level listed in the specifications. Then, if the low frequency channels are above the optimum input level range, a fixed input equalizer can be installed to drop the low frequency channels to within this range. Use the slope control to make fine adjustments.

INSTALLING FORWARD PATH INPUT ATTENUATOR

Remove top cover as described below. If input levels are enough to cause a high distortion level in the input amplifier, a fixed input attenuator may be added. Choose an SXP type attenuator of the value required, and install at the location indicated below. Remove the 0 dB wire jumper to allow insertion of the attenuator.

INSTALLING AN INPUT EQUALIZER

Follow the same basic procedure as described above for the input attenuator except that the equalizer is installed at the equalizer location shown below:

RF INPUT OF REAR PANEL

IN OUT

GROUND

IN

GROUND

OUT

FIXED INPUT ATTENUATOR

LOCATION

A factory installed jumper is installed here for no attenuation. To install an input attenuator, remove jumper and plug in a "SXP" type attenuator rated for the same or higher frequency as the amplifier.

INPUT EQUALIZER

LOCATION

A factory installed jumper is installed here for no equalization. Install desired

"QSA" type equalizer here. If equalizer is not used, the jumper must be connected between the IN and OUT connections.

4 Specifications and Warranty

SPECIFICATIONS COMMON TO ALL MODELS (unless otherwise noted)

Forward Gain Adjustment Range:

Slope Control Adjustment (54 MHz):

Input/Output Impedances:

Input and Output Monitor Ports:

Fixed Input Attenuator:

Fixed Input Equalizer:

Hum Modulation:

Frequency Coverage (return port):

RF Shielding:

10 dB minimum (except DAR8618).

10 dB minimum (except DAR8618).

75 Ohms.

- 30 dB.

Plug-in (SXP type) available.

Plug-in (QSA type) available.

- 70 dB.

5 to 42 MHz.

Leakage complies with FCC Part 76.

Power Requirement: Models DAR7533, 7542, 8633, 8642 -

115 VAC, 60 Hz, 24 Watts;

Model DAR8618 -

115 VAC, 60 Hz, 18 Watts.

Operating

Temperature Range:

Size:

Weight:

- 20 deg. to + 60 deg. C.

19.00" (48.3 cm) W x 7.5" (19.1 cm) D x 1.75" (4.5 cm) H.

6 lbs. 4 oz. (2.9 Kg).

ADDITIONAL SPECIFICATIONS FOR SPECIFIC MODELS

Frequency Coverage (forward path):

Forward Gain:

Noise Figure:

Return Loss, Input & Output:

Channel Loading:

Output Level (maximum per channel for distortions listed below):

Input Level (maximum without using fixed input attenuator):

Optimum Input Level Range for Best Performance:

DAR7533

54 to 750 MHz.

33 dB.

7 dB maximum.

14 dB.

110 CH.

+44 dBmV.

+20 dBmV.

+10 dBmV to

+15 dBmV.

Nonlinear Distortions-

Composite Triple Beat:

Composite Second Order:

Cross-modulation:

- 58 dB.

- 58 dB.

- 60 dB.

DAR7542

54 to 750 MHz.

42 dB.

6.5 dB maximum.

14 dB.

110 CH.

+44 dBmV.

+10 dBmV.

+0 dBmV to

+5 dBmV.

- 58 dB.

- 58 dB.

- 60 dB.

DAR8633

54 to 860 MHz.

33 dB.

7.5 dB maximum.

14 dB.

129 CH.

+40 dBmV.

+18 dBmV.

+7 dBmV to

+12 dBmV.

- 60 dB.

- 60 dB.

- 64 dB.

DAR8642

54 to 860 MHz.

42 dB.

7 dB maximum.

14 dB.

129 CH.

+40 dBmV.

+7 dBmV.

-3 dBmV to

+2 dBmV.

- 60 dB.

- 60 dB.

- 64 dB.

DAR8618

54 to 860 MHz.

18 dB.

7.5 dB maximum.

14 dB.

129 CH.

+40 dBmV.

+22 dBmV.

N/A

- 61 dB.

- 60 dB.

- 68 dB.

R.L. DRAKE COMPANY warrants to the original purchaser this product shall be free from defects in material or workmanship for three (3) years from the date of original purchase. During the warranty period the R.L. DRAKE COMPANY or an authorized Drake service facility will provide, free of charge, both parts and labor necessary to correct defects in material and workmanship. At its option, R.L. DRAKE COMPANY may replace a defective unit.

- To obtain such warranty service, the original purchaser must:

(a) the model and serial number,

(b) the identity of the seller and the approximate date of purchase; and

(c) A detailed description of the problem, including details on the electrical connection to associated equipment and the list of such equipment.

fully insured and shipping charges prepaid.

- Correct maintenance, repair, and use are necessary to obtain proper performance from this product. Therefore carefully read the

Instruction Manual. This warranty does not apply to any defect that R.L. DRAKE COMPANY determines is due to: parts.

- All implied warranties, if any, including warranties of merchantability and fitness for a particular purpose, terminate three (3) years from the date of the original purchase.

- The foregoing constitutes R.L. DRAKE COMPANY’S entire obligation with respect to this product, and the original purchaser shall have no other remedy and no claim for incidental or consequential damages, losses or expenses. Some states do not allow limitations on how long an implied warranty lasts or do not allow the exclusions or limitation of incidental or consequential damages, so the above limitation and exclusion may not apply to you.

- This warranty gives you specific legal rights and you may also have other rights which vary from state to state. This warranty shall be construed under the laws of Ohio.

®

R.L. DRAKE COMPANY

230 INDUSTRIAL DRIVE

FRANKLIN, OHIO 45005 U.S.A.

CUSTOMER SERVICE AND PARTS TELEPHONE: +1 (937) 746-6990

TELEFAX: +1 (937) 743-4576

WORLD WIDE WEB SITE: http://www.rldrake.com

® is a registered trademark of the R.L. Drake Company © Copyright 2001 R.L. Drake Company P/N: 3852719C-11-2001 Printed in the U.S.A.

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Frequently Answers and Questions

What is the maximum channel loading capacity of the DRAKE DAR8633?
The DRAKE DAR8633 can handle up to 129 channels.
What is the frequency coverage range of the device?
The DRAKE DAR8633 covers a frequency range of 54 to 860 MHz for the forward path and 5 to 42 MHz for the return path.
What is the maximum output level per channel for the DRAKE DAR8633?
The maximum output level per channel is +40 dBmV with distortions of -58 dB for composite triple beat, -58 dB for composite second order, and -60 dB for cross-modulation.
What is the optimum input level range for best performance of the DRAKE DAR8633?
The optimum input level range for best performance is +7 dBmV to +12 dBmV.
What is the warranty period for the DRAKE DAR8633?
The DRAKE DAR8633 comes with a three-year limited warranty from the date of original purchase.