Millar TC-510 Datasheet

Add to my manuals
6 Pages

advertisement

Millar TC-510 Datasheet | Manualzz

• FAST SHIPPING AND

DELIVERY

• TENS OF THOUSANDS OF

IN-STOCK ITEMS

• EQUIPMENT DEMOS

• HUNDREDS OF

MANUFACTURERS

SUPPORTED

• LEASING/MONTHLY

RENTALS

• ITAR CERTIFIED

SECURE ASSET SOLUTIONS

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

SERVICE CENTER REPAIRS

Experienced engineers and technicians on staff at our full-service, in-house repair center

Instra

View

SM REMOTE INSPECTION

Remotely inspect equipment before purchasing with our interactive website at www.instraview.com

WE BUY USED EQUIPMENT

Sell your excess, underutilized, and idle used equipment

We also offer credit for buy-backs and trade-ins www.artisantg.com/WeBuyEquipment

LOOKING FOR MORE INFORMATION?

Visit us on the web at www.artisantg.com

for more information on price quotations, drivers, technical specifications, manuals, and documentation

Contact us: (888) 88-SOURCE | [email protected] | www.artisantg.com

TC-510 Pressure Control Unit

® AT THE HEART OF SENSOR INNOVATION®

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

TC-510 Pressure Control Unit

The TC-510 Pressure Control Unit a passive interface between the Millar Mikro-Tip catheter pressure transducer and strain gauge pressure monitors which supply bridge excitation voltage and have balance and calibration controls for full-bridge strain gauge pressure transducers. The TC-510 has an internal calibration circuit to provide an electrical zero as well as a 100 mmHg calibration signal. The output connector is a standard 9-pin sub-D. A separate monitor interface cable is required.

Pressure Control Unit Ordering Information

Input

Model Part Connector

Number Number Channels Type

TC-510 851-5918 One Viking

NOTE: Viking connectors are round with 4 pins.

Isolated

Input/Output

No

Output

Connector

Type

9 pin sub-D

Mikro-Tip Catheter Pressure Interface Cables

Mikro-Tip Pressure Catheters are provided with either Viking (4-pin) or Millar Low Profile (4-pin) connectors depending on the model purchased. Catheter models with Viking connectors may connect directly to the TC-510.

Connecting the catheter with a Viking connector directly to the control unit limits access to the subject or patient.

It is recommended that a TEC-10C interface cable be used between the catheter and control unit. All catheters with low profile pressure connectors require a TEC-10D interface cable to the control unit. Each pressure channel requires a separate interface cable and control unit.

Viking Connector

(TEC-10C)

Low Profile Connector

(TEC-10D)

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Adapter/Interface Cable Ordering Information

Cable

Model

TEC-5C

TEC-10C

TEC-10D

Number

850-1118

850-1108

850-1308

Length

5 ft. (152 cm)

10 ft. (304 cm)

10 ft. (304 cm)

Catheter End

Type

Viking

Viking

Low Profile

Control Unit

Connector

Type

Viking

Viking

Viking

NOTE: Viking connectors are round with 4 pins. Low Profile connectors are flat with 4 pins. The above flexible cables facilitate maneuvering the catheter during recording.

They may be sterilized and permit connection of a catheter to a Pressure Control Unit located outside the sterile field.

TC-510 Pressure Control Unit Output Cable

Control Unit

Cable Part Cable Connector

Model Number Length Type

TC-510 Output Monitor Cable 850-3008 6.5 ft. (198 cm) 9 pin sub-D

Monitor

Connector

Type

Open ended, not wired

NOTE: A selection is available from Millar of other TC-510 output cables that are wired for a variety of monitor and recorder inputs. Please contact our Customer Service

Department for availability.

When ordering please specify the following:

• Data Acquisition System/Recorder/Preamp/Coupler manufacturer. Example: Hewlett Packard

• Preamp/Coupler models. Example: 8805D

• Specify Connector and pin-out. Example: Hewlett Packard TWINAX or Cannon WK6-21C

• Indicate if an intermediate connector panel, i.e., “patch panel,” is to be used with the recorder.

TC-510 connectivity

TEC Cable

Pressure Input

TC-510

Interface Cable

Strain Gauge

Amplifier

DAQ or Monitor

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

World Headquarters

Millar Instruments, Inc.

6001-A Gulf Freeway

Houston, Texas 77023-5417 USA

Phone: 832-667-7000 or 800-669-2343 (in the USA)

Fax:

Email:

832-667-7001 [email protected]

Web site: www.millarinstruments.com

Millar Worldwide Distribution

Millar Instruments, Inc. has a network of Authorized Distributors in most countries around the world. For information on the Millar distributor in your country, please contact the Millar Customer Service Department at our headquarters in Houston.

Authorized Representative for the European Community

BOSA S.p.A.

Via Sardegna n°61

20146 Milano

Italy

Telephone: +39-02-48011-693

Fax: +39-02-468564

Email: [email protected]

® AT THE HEART OF SENSOR INNOVATION®

© 2002, 2004 Millar Instruments, Inc.

Millar, Mikro-Tip, and At the Heart of Sensor Innovation are registered trademarks of Millar Instruments, Inc.

Products and company names used are the trademarks or trade names of their respective companies.

Models referred to herein are protected by USA and International patents. All product specifications are subject to change without notice.

M.I. P/N 005-1050 Rev. --

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

• FAST SHIPPING AND

DELIVERY

• TENS OF THOUSANDS OF

IN-STOCK ITEMS

• EQUIPMENT DEMOS

• HUNDREDS OF

MANUFACTURERS

SUPPORTED

• LEASING/MONTHLY

RENTALS

• ITAR CERTIFIED

SECURE ASSET SOLUTIONS

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

SERVICE CENTER REPAIRS

Experienced engineers and technicians on staff at our full-service, in-house repair center

Instra

View

SM REMOTE INSPECTION

Remotely inspect equipment before purchasing with our interactive website at www.instraview.com

WE BUY USED EQUIPMENT

Sell your excess, underutilized, and idle used equipment

We also offer credit for buy-backs and trade-ins www.artisantg.com/WeBuyEquipment

LOOKING FOR MORE INFORMATION?

Visit us on the web at www.artisantg.com

for more information on price quotations, drivers, technical specifications, manuals, and documentation

Contact us: (888) 88-SOURCE | [email protected] | www.artisantg.com

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement