Direct Operated Pressure Regulator
BRV2
The BRV2 is a direct acting pressure reducing valve suitable for steam or gases, such as compressed air.
Model
➪
Sizes
Connections
Construction
Options
BRV2S
1/2" , 3/4", 1"
NPT
Ductile Iron
BRV2B with phosphor bronze/brass bellows assembly
BRV2SP & BRV2SB optional types with external pressure sensing
16
2
18
3
4
7
C
ONSTR UCTION
M
ATERIALS
17
18
19
20
8
9
10
11
12
13
14
15
16
3
4
No.
Part
1 Spring Housing
2 Adjustment Hand Wheel
5
6
7
Top Spring Plate
Pressure Adjustment
Spring
Material
Aluminum Epoxy Coated
Mineral Reinforced Nylon
Cast Iron
Silicone Chrome
Spring Steel
Bellows Assembly Option Stainless Steel
Phosphor Bronze/Brass
Bellows Assembly Gasket Stainless Steel Reinforced
Exfoliated Graphite
Spring Housing Bolts Steel–Zinc plated
M8 x 25 mm
Body - Screwed & Flanged SG Iron
Guide Bush Graphite Filled PTFE
Pushrod
Valve Seat
Valve Seat Gasket
Valve
Valve Return Spring
Strainer Screen
Spring Range
Identification Disc
Stainless Steel
Stainless Steel
Stainless Steel
Stainless Steel
Stainless Steel
Stainless Steel
Polypropylene
Bulkhead Plate
Tamperproof Pin
Blanking Plub
Compression Fitting
Stainless Steel
Mild Steel - Copper Plated
Stainless Steel
Brass
Material Spec.
LM 24
DIN 1691 GG 20
BS 2803 685 A55
Range 2
316Ti/316L
BS 3692 Gr 8.8
DIN 1693 GGG40.3
ASTM A276 Gr 316L
BS 970 431 S29
BS 1449 316 S11
AISI 420
BS 20056 316 S42
BS 1449 316 SH
316L
BS970 431 S29
L
IMITING
O
PERATING
C
ONDITIONS
-
STEAM OR GAS
Max. Upstream Pressure
Max. Downstream Pressure
Max. Operating Temperature
Max. Cold Hydraulic Test
275 psig (19 barg)
115 psig (8.0 barg)
410˚F (210˚C)
550 psig (38 barg)
Max. Recommended Turndown Ratio 10:1 psig at Maximum Flow
Shutoff ANSI Class IV
400
Pressure barg
0 2 4 6 8 10 12 14 16 1819
200
1
6
5
T
YPICAL
A
PPLICATIONS
Small steam or gas pressure reducing applications.
18
8
9
17
10
12
11
13
14
15
1
20
19
200 100
50
Do not use in this region
100 150
Pressure psig
200 250 275
D
OWNSTREAM
P
RESSURE
R
ANGES
For the following downstream pressures, three color-coded springs are available. Where the pressures overlap, use the lowest pressure spring to give the downstream pressure required:
Grey: 2 to 25 psig Green:
0.14 to 1.7 barg
20 to 60 psig
1.4 to 4.0 barg
Orange:
3.5 to 8.6 barg
50 to 125 psig
D
IMENSIONS
(
NOMINAL
)
IN INCHES AND MILLIMETERS
Size A C D E
Withdrawal
Distance
Weight
1/2" 3.3
83
2.2
55
5.0
1.0
126.5
25
3.4 lb
1.55 kg
3/4"
1"
3.8
96
4.25
108
2.2
55
2.2
55
5.0
1.0
126.5
25
5.0
1.0
126.5
25
3.6 lb
1.65 kg
4.2 lb
1.90 kg
Local regulation may restrict the use of this product below the conditions quoted. Limiting conditions refer to standard connections only.
In the interests of development and improvement of the product, we reserve the right to change the specification.
TI-3-107-US 07.97
Direct Operated Pressure Regulator
BRV2
C
APACITIES – Saturated steam capacities in lb/h
Full lift capacities for safety valve sizing are shown below:
Cvs (Kvs)
1/2" (DN15)
1.8
(1.5)
3/4" (DN20)
2.9
(2.5)
1" (DN25)
3.5
(3.0)
Q
S
PARE
P
AR TS
150
(10)
165
(11)
180
(12)
195
(13)
245
(17)
125
(8.6)
120 (8)
105 (7)
90 (6)
75 (5)
60 (4)
45 (3)
30 (2)
15 (1)
0
Steam
Capacity lb/h
0
0
0
0
Compressed
Air Capacity cfm Free Air
0
0
30 (2)
45
(3)
60
(4)
75
(5)
105
(7)
90
(6)
120
(8)
Upstream pressure psig (barg)
Pressure
Adjustment
Spring
F
80
100
150
160
200
300
240
300
450
320
400
600
400
500
750
480 560 1/2" DN 15
600 700 3/4" DN 20
900 1050 1" DN 25
J
Valve
& Seat
Assembly
L
M
20
20
40
40
40
60
60 80 100 120 140 160 180 200
1/2" DN 15
80 100 120 140 160 180 200 220 240
3/4" DN 20
80 120 160 200 240 280 320 380
1" DN 25
D
G Spring
Housing
Bolts
E
F
F
Bellows Set
Gasket Set
M
H
OW TO USE THE CHAR T
The curved lines labelled 30, 45, 60, etc., represent upstream pressures. Downstream pressures are read along the vertical line on the left hand side of the chart.
Example:
Required, a reducing valve to pass 160 lb/h reducing from 150 to 60 psi. From the downstream pressure of 60 on the left hand side of the chart extend out horizontally until the line meets the curved 150 psi upstream line. At this point, read vertically downward where it will be seen that 1/2" BRV2 will be required.
I
NSTALLATION AND
M
AINTENANCE
The valve should be installed in a horizontal pipeline with the direction of flow as indicated by the arrow on the valve body.
When the required set pressure has been achieved, the tamper proof pin may be used to prevent further pressure adjustments.
Any strainer fitted upstream of the BRV2S, and the strainer screen fitted inside the valve should be cleaned regularly so that the flow to the valve is not restricted. Full Installation and Maintenance Instructions are supplied with each product.
BRV2SP/BRV2BP
When external pressure sensing is used, remove the blanking plug (19) and fit the
1/8"/6mm O/D compressing fitting (20-supplied). The other end of the 6mm sensing pipe should be connected into the downstream pipework at least 1m downstream from the valve. For more detail, see Installation and Maintenance Instructions.
Spirax Sarco, Inc., 1150 Northpoint Blvd, Blythewood, SC 29016
Spare Parts
The spare parts available are shown in heavy outline.
Parts drawn in broken line are not supplied as spares.
AVAILABLE SPARE
Valve and seat assembly
* Bellows (Stainless Steel)
Option
* Spring Housing Cap Screw (set of 4)
F,M,L,J
E,F
Phosphor Bronze/Brass
G
D,Q * Pressure Adjustment Spring
Grey 2-25 psig • Green 20-60 psig
Orange 50-125 psig
* Set of all gaskets F,M
* Common to all sizes.
How to order
Always order spares by using the description given in the column headed Available Spare and stating the size, type and pressure range of the reducing valve.
Example:Pressure Adjustment Spring, pressure range
50-125 psig (orange) for 1/2" Spirax Sarco Type
BRV2 Reducing Valve.
TI-3-107-US 07.97