hammond spartan

hammond spartan
HPS Spartan®
Industrial Open Core & Coil
Control Transformer
®
Our Company
Hammond Power Solutions (HPS) was established in 1917 in Guelph, Ontario and has grown from a
small family owned business in the short wave radio market, to the industry leader in magnetic transformer
design and manufacturing. HPS has manufacturing facilities in Compton, California; Guelph, Ontario;
Walkerton, Ontario; Granby, Quebec; and Monterrey, Mexico. HPS currently has multiple regional
distribution centers throughout North America.
Value
The HPS Spartan® series of industrial control transformers are ideally suited for general purpose, industrial
and light duty loads.
Designed for applications where high inrush or machine tool duty are not necessary, the HPS Spartan
control transformer offers an efficient and economical solution.
Applications
The HPS Spartan® is the perfect solution for HVAC applications, signal and alarm systems, motor control
circuits, lighting and circuit isolation.
Industries
•
•
•
•
•
Commercial
Agriculture
Security
Automation
Solar
Features and Benefits
•
Molded terminal blocks for primary and secondary
connections up to 3000 VA or 30 amps. Coil face
termination over 3000 VA or 30 amps.
•
All HPS Spartan units are supplied with
trilingual installation and wiring instruction
sheets.
•
All terminal blocks utilize a combination slot/
Phillips #6 screw with a SEMS washer (Suitable for
18 AWG to 14 AWG for solid wire and 18 AWG to
12 AWG for stranded wire). Coil face terminations
utilize a ¼-20 UNC X 0.50” combination slot/
Phillips screw and a spring lock washer.
•
All units supplied with primary and secondary
voltage links/jumpers.
•
All HPS Spartan® transformers are Vacuum
Impregnated with Polyester Resin and oven
cured.
•
50/60 Hz (60 Hz on SP***ACP and SP***AR).
•
Bolted core construction.
•
Copper wound coils with high dielectric strength
insulation.
•
Bolt-on mounting brackets.
•
15 year warranty.
•
CSA Certified (file LR 3902), UL Listed (file
E50394), CE Marked and RoHS Compliant.
•
Meets NEMA standards.
•
Superior insulating materials. The HPS Spartan
offers the following insulation systems:
Up to 1500 VA: 80°C rise,
130°C temperature class (B)
2000 VA to 5000 VA: 115°C rise,
180°C temperature class (F)
•
Most HPS Spartan units incorporate “Premium
Packaging” which feature:
- Premium fluted cartons
- Custom molded foam inserts
- Easy removal and repacking
- Industry’s best box label
®
Group A
Primary Voltage: Secondary Voltage: VA
Rating
CE VA
Rating
Catalog
Number
600/480
120 x 240
Mtg.
Fig.
Output
Amps
575/460550/440
115 x 230 110 x 220
Overall
Dimensions
A
B
Mounting
Centers
C
D
E
60 Hertz
Mounting
Slot
GXH
Height
with
Finger
Guard
Height
with
Fuse
Block
Adapter
Approx.
Ship
Weight
Lbs.
50
50
SP50ACP
A
0.42/0.21
2.60
3.82
2.60
2.13
2.64
0.22 x 0.44
2.98
2.79
2.2
100
100
SP100ACP
A
0.83/0.42
2.99
3.74
2.85
2.52
2.60
0.22 x 0.44
3.23
3.04
3.3
150
150
SP150ACP
A
1.25/0.63
2.99
4.29
2.85
2.52
3.15
0.22 x 0.44
3.23
3.04
4.4
250
160
SP250ACP
A
2.08/1.04
3.78
4.09
3.40
3.31
2.99
0.22 x 0.44
3.78
3.59
6.4
350
250
SP350ACP
A
2.92/1.46
3.78
4.49
3.40
3.31
3.39
0.22 x 0.44
3.78
3.59
7.5
500
300
SP500ACP
A
4.17/2.08
4.49
4.69
3.78
3.78
3.66
0.31 x 0.81
4.16
3.97
11
1
750
500
SP750ACP
A
6.25/3.13
5.25
5.08
4.37
4.50
4.06
0.31 x 0.81
4.75
4.56
18
1000
650
SP1000ACP
A
8.33/4.17
5.25
5.471
4.37
4.50
4.45
0.31 x 0.81
4.75
4.56
21
1500
1000
SP1500ACP
A
12.5/6.25
5.25
6.85
1
4.37
4.50
5.83
0.31 x 0.81
4.56
4.37
28
2000
1300
SP2000ACP
A
16.7/8.33
6.38
5.871
5.31
5.75
4.84
0.31 x 0.81
5.69
5.50
34
3000
2000
SP3000ACP
A
25.0/12.5
7.50
7.50
6.50
6.30
6.85
0.44 x 1.00
6.50
6.50
60
5000
3000
SP5000ACP
C
41.7/20.8
8.98
9.88
7.76
7.40
7.13
0.44 x 1.00
N/A
N/A
93
Primary and Secondary voltage links/jumpers supplied standard with all transformers.
Special voltages and VA sizes available upon request.
1
Note: For 750 through 2000 VA units actual overall depth is 0.24” plus the value in column B.
* See page 10 for dimensional drawings.
All dimensions in inches
Group B
Primary Voltage: Secondary Voltage: 600
12 x 24
VA
Rating
CE VA
Rating
Catalog
Number
Mtg.
Fig.
Output
Amps
50
50
SP50AR
A
4.17/2.08
575
11.5 x 23
550
11 x 22
Overall
Dimensions
60 Hertz
Mounting
Centers
Mounting
Slot
A
B
C
D
E
GXH
Height
with
Finger
Guard
2.60
3.23
2.60
2.13
2.05
0.22 x 0.44
2.98
Height
with
Fuse
Block
Adapter
Approx.
Ship
Weight
Lbs.
2.79
1.5
100
100
SP100AR
A
8.33/4.17
2.99
3.74
2.85
2.52
2.60
0.22 x 0.44
3.23
3.04
3.3
150
150
SP150AR
A
12.5/6.25
2.99
4.09
2.85
2.52
2.95
0.22 x 0.44
3.23
3.04
3.9
250
160
SP250AR
A
20.8/10.4
3.78
3.70
3.40
3.31
2.60
0.22 x 0.44
3.78
3.59
5.2
350
250
SP350AR
A
29.2/14.6
3.78
4.29
3.40
3.31
3.19
0.22 x 0.44
3.78
3.59
7.1
500
300
SP500AR
B
41.7/20.8
4.49
5.08
3.78
3.78
3.27
0.31 x 0.81
4.16
3.97
9.9
Primary and Secondary voltage links/jumpers supplied standard with all transformers.
Special voltages and VA sizes available upon request.
* See page 10 for dimensional drawings.
All dimensions in inches
Group C
Primary Voltage: Secondary Voltage: VA
Rating
CE VA
Rating
240 x 480
120 x 240
Catalog
Number
Mtg.
Fig.
Output
Amps
230 x 460
115 x 230
220 x 440
110 x 220
Overall
Dimensions
50/60 Hertz
Mounting
Centers
Mounting
Slot
A
B
C
D
E
GXH
Height
with
Finger
Guard
Height
with
Fuse
Block
Adapter
Approx.
Ship
Weight
Lbs.
50
50
SP50MQMJ
A
0.42/0.21
2.60
3.35
2.60
2.13
2.17
0.22 x 0.44
2.98
2.79
1.7
100
100
SP100MQMJ
A
0.83/0.42
2.99
3.74
2.85
2.52
2.60
0.22 x 0.44
3.23
3.04
3
150
150
SP150MQMJ
A
1.25/0.63
2.99
4.29
2.85
2.52
3.15
0.22 x 0.44
3.23
3.04
4.3
250
160
SP250MQMJ
A
2.08/1.04
3.78
4.09
3.40
3.31
2.99
0.22 x 0.44
3.78
3.59
6.5
350
250
SP350MQMJ
A
2.92/1.46
3.78
4.69
3.40
3.31
3.58
0.22 x 0.44
3.78
3.59
8.2
500
300
SP500MQMJ
A
4.17/2.08
4.49
4.69
3.78
3.78
3.66
0.31 x 0.81
4.16
3.97
11
1
750
500
SP750MQMJ
A
6.25/3.13
5.25
4.69
4.37
4.50
3.66
0.31 x 0.81
4.75
4.56
16
1000
650
SP1000MQMJ
A
8.33/4.17
5.25
5.471
4.37
4.50
4.45
0.31 x 0.81
4.75
4.56
21
1500
1000
SP1500MQMJ
A
12.5/6.25
5.25
1
6.85
4.37
4.50
5.83
0.31 x 0.81
4.75
4.56
28
2000
1300
SP2000MQMJ
A
16.7/8.33
6.38
5.871
5.31
5.75
4.84
0.31 x 0.81
5.50
5.31
35
3000
2000
SP3000MQMJ
A
25.0/12.5
7.50
7.50
6.50
6.30
7.28
0.44 x 1.00
6.50
6.50
64
5000
3000
SP5000MQMJ
C
41.7/20.8
8.98
9.88
7.76
7.40
7.28
0.44 x 1.00
N/A
N/A
97
Primary and Secondary voltage links/jumpers supplied standard with all transformers.
Special voltages and VA sizes available upon request.
1
Note: For 750 through 2000 VA units actual overall depth is 0.24” plus the value in column B.
* See page 10 for dimensional drawings.
All dimensions in inches
Group D
Primary Voltage: Secondary Voltage: VA
Rating
CE VA
Rating
Catalog
Number
240 x 480
12 x 24
Mtg.
Fig.
Output
Amps
230 x 460
11.5 x 23
220 x 440
11 x 22
Overall
Dimensions
A
B
Mounting
Centers
C
D
E
50/60 Hertz
Mounting
Slot
GXH
Height
with
Finger
Guard
Height
with
Fuse
Block
Adapter
Approx.
Ship
Weight
Lbs.
50
50
SP50QR
A
4.17/2.08
2.60
3.35
2.60
2.13
2.17
0.22 x 0.44
2.98
2.79
1.7
100
100
SP100QR
A
8.33/4.17
2.99
3.54
2.85
2.52
2.40
0.22 x 0.44
3.23
3.04
3
150
150
SP150QR
A
12.5/6.25
2.99
4.29
2.85
2.52
3.15
0.22 x 0.44
3.23
3.04
4.3
250
160
SP250QR
A
20.8/10.4
3.78
4.09
3.40
3.31
2.99
0.22 x 0.44
3.78
3.59
6.5
350
250
SP350QR
A
29.2/14.6
3.78
4.69
3.40
3.31
3.58
0.22 x 0.44
3.78
3.59
8.3
500
300
SP500QR
B
41.7/20.8
4.49
5.47
3.78
3.78
3.66
0.31 x 0.81
4.16
3.97
11
Primary and Secondary voltage links/jumpers supplied standard with all transformers.
Special voltages and VA sizes available upon request.
* See page 10 for dimensional drawings.
All dimensions in inches
®
Group E
Primary Voltage: Secondary Voltage: 380/347
120 x 240
50/60 Hertz
Overall
Dimensions
Mounting
Centers
Mounting
Slot
Height
with
Fuse
Block
Adapter
Approx.
Ship
Weight
Lbs.
A
B
C
D
E
GXH
Height
with
Finger
Guard
0.42/0.21
2.60
3.35
2.60
2.13
2.17
0.22 x 0.44
2.98
2.79
1.7
A
0.83/0.42
2.99
3.74
2.85
2.52
2.60
0.22 x 0.44
3.23
3.04
3.4
A
1.25/0.63
2.99
4.29
2.85
2.52
3.15
0.22 x 0.44
3.23
3.04
4.4
SP250KHP
A
2.08/1.04
3.78
4.09
3.40
3.31
2.99
0.22 x 0.44
3.78
3.59
6.7
250
SP350KHP
A
2.92/1.46
3.78
4.69
3.40
3.31
3.58
0.22 x 0.44
3.78
3.59
8.4
300
SP500KHP
A
4.17/2.08
4.49
4.69
3.78
3.78
3.66
0.31 x 0.81
4.16
3.97
12
1
VA
Rating
CE VA
Rating
Catalog
Number
Mtg.
Fig.
Output
Amps
50
50
SP50KHP
A
100
100
SP100KHP
150
150
SP150KHP
250
160
350
500
750
500
SP750KHP
A
6.25/3.13
5.25
4.69
4.37
4.50
3.66
0.31 x 0.81
4.75
4.56
17
1000
650
SP1000KHP
A
8.33/4.17
5.25
5.471
4.37
4.50
4.45
0.31 x 0.81
4.75
4.56
21
1500
1000
SP1500KHP
A
12.5/6.25
6.38
4.88
5.31
5.75
3.86
0.31 x 0.81
5.50
5.31
29
1
All dimensions in inches
Primary and Secondary voltage links/jumpers supplied standard with all transformers.
Special voltages and VA sizes available upon request.
1
Note: For 750 through 1500 VA units actual overall depth is 0.24” plus the value in column B.
* See page 10 for dimensional drawings.
Group F
Primary Voltage: Secondary Voltage: VA
Rating
CE VA
Rating
Catalog
Number
380/347
12 x 24
Mtg.
Fig.
Output
Amps
50/60 Hertz
Overall
Dimensions
A
B
Mounting
Centers
C
D
E
Mounting
Slot
GXH
Height
with
Finger
Guard
Height
with
Fuse
Block
Adapter
Approx.
Ship
Weight
Lbs.
50
50
SP50KHR
A
4.17/2.08
2.60
3.35
2.60
2.13
2.17
0.22 x 0.44
2.98
2.79
1.7
100
100
SP100KHR
A
8.33/4.17
2.99
3.74
2.85
2.52
2.60
0.22 x 0.44
3.23
3.04
3.3
150
150
SP150KHR
A
12.5/6.25
2.99
4.29
2.85
2.52
3.15
0.22 x 0.44
3.23
3.04
4.4
250
160
SP250KHR
A
20.8/10.4
3.78
4.09
3.40
3.31
2.99
0.22 x 0.44
3.78
3.59
6.4
350
250
SP350KHR
A
29.2/14.6
3.78
4.69
3.40
3.31
3.58
0.22 x 0.44
3.78
3.59
8.1
500
300
SP500KHR
B
41.7/20.8
4.49
5.47
3.78
3.78
3.66
0.31 x 0.81
4.16
3.97
11
Primary and Secondary voltage links/jumpers supplied standard with all transformers.
Special voltages and VA sizes available upon request.
* See page 10 for dimensional drawings.
All dimensions in inches
Group G
Primary Voltage: Secondary Voltage: VA
Rating
CE VA
Rating
277
120
50/60 Hertz
Catalog
Number
Mtg.
Fig.
Output
Amps
Overall
Dimensions
Mounting
Centers
Mounting
Slot
A
B
C
D
E
GXH
Height
with
Finger
Guard
Height
with
Fuse
Block
Adapter
Approx.
Ship
Weight
Lbs.
50
50
SP50NJ
A
0.42
2.60
3.35
2.60
2.13
2.17
0.22 x 0.44
2.98
2.79
1.6
100
100
SP100NJ
A
0.83
2.99
3.54
2.85
2.52
2.40
0.22 x 0.44
3.23
3.04
3.2
150
150
SP150NJ
A
1.25
2.99
4.29
2.85
2.52
3.15
0.22 x 0.44
3.23
3.04
4.3
250
160
SP250NJ
A
2.08
3.78
4.09
3.40
3.31
2.99
0.22 x 0.44
3.78
3.59
6.4
350
250
SP350NJ
A
2.92
3.78
4.69
3.40
3.31
3.58
0.22 x 0.44
3.78
3.59
8.1
500
300
SP500NJ
A
4.17
4.49
4.69
3.78
3.78
3.66
0.31 x 0.81
4.16
3.97
11
1
750
500
SP750NJ
A
6.25
5.25
5.08
4.37
4.50
4.06
0.31 x 0.81
4.75
4.56
18
1000
650
SP1000NJ
A
8.33
5.25
5.471
4.37
4.50
4.45
0.31 x 0.81
4.75
4.56
20
1500
1000
SP1500NJ
A
12.50
5.25
6.85
4.37
4.50
5.83
0.31 x 0.81
4.75
4.56
29
1
Primary and Secondary voltage links/jumpers supplied standard with all transformers.
Special voltages and VA sizes available upon request.
1
Note: For 750 through 1500 VA units actual overall depth is 0.24” plus the value in column B.
* See page 10 for dimensional drawings.
All dimensions in inches
Group H
Primary Voltage: Secondary Voltage: VA
Rating
CE VA
Rating
120 x 240
12 x 24
Catalog
Number
Mtg.
Fig.
Output
Amps
115 x 230
11.5 x 23
110 x 220
11 x 22
Overall
Dimensions
Mounting
Centers
50/60 Hertz
Mounting
Slot
A
B
C
D
E
GXH
Height
with
Finger
Guard
Height
with
Fuse
Block
Adapter
Approx.
Ship
Weight
Lbs.
50
50
SP50PR
A
4.17/2.08
2.60
3.35
2.60
2.13
2.17
0.22 x 0.44
2.98
2.79
1.7
100
100
SP100PR
A
8.33/4.17
2.99
3.74
2.85
2.52
2.60
0.22 x 0.44
3.23
3.04
3
150
150
SP150PR
A
12.5/6.25
2.99
4.29
2.85
2.52
3.15
0.22 x 0.44
3.23
3.04
4.3
250
160
SP250PR
A
20.8/10.4
3.78
3.90
3.40
3.31
2.80
0.22 x 0.44
3.78
3.59
5.9
350
250
SP350PR
A
29.2/14.6
3.78
4.69
3.40
3.31
3.58
0.22 x 0.44
3.78
3.59
8.2
500
300
SP500PR
B
41.7/20.8
4.49
5.47
3.78
3.78
3.66
0.31 x 0.81
4.16
3.97
11
Primary and Secondary voltage links/jumpers supplied standard with all transformers.
Special voltages and VA sizes available upon request.
* See page 10 for dimensional drawings.
All dimensions in inches
®
Group I
Primary Voltage: Secondary Voltage: VA
Rating
CE VA
Rating
Catalog
Number
208 x 416
120 x 240
Mtg.
Fig.
Output
Amps
200 x 400
115 x 230
190 x 380
110 x 220
Overall
Dimensions
A
B
Mounting
Centers
C
D
E
50/60 Hertz
Mounting
Slot
GXH
Height
with
Finger
Guard
Height
with
Fuse
Block
Adapter
Approx.
Ship
Weight
Lbs.
1.6
50
50
SP50SP
A
0.42/0.21
2.60
3.35
2.60
2.13
2.17
0.22 x 0.44
1.6
2.60
100
100
SP100SP
A
0.83/0.42
2.99
3.54
2.85
2.52
2.40
0.22 x 0.44
3
2.85
3
150
150
SP150SP
A
1.25/0.63
2.99
4.29
2.85
2.52
3.15
0.22 x 0.44
4.3
2.85
4.3
250
160
SP250SP
A
2.08/1.04
3.78
4.09
3.40
3.31
2.99
0.22 x 0.44
6.5
3.40
6.5
350
250
SP350SP
A
2.92/1.46
3.78
4.69
3.40
3.31
3.58
0.22 x 0.44
8.3
3.40
8.3
500
300
SP500SP
A
4.17/2.08
4.49
4.69
3.78
3.78
3.66
0.31 x 0.81
11
3.78
11
750
500
SP750SP
A
6.25/3.13
5.25
4.691
4.37
4.50
3.66
0.31 x 0.81
16
4.75
16
1000
650
SP1000SP
A
8.33/4.17
5.25
5.471
4.37
4.50
4.45
0.31 x 0.81
20
4.75
20
1500
1000
SP1500SP
A
12.5/6.25
6.38
4.881
5.31
5.75
3.86
0.31 x 0.81
27
5.69
27
Primary and Secondary voltage links/jumpers supplied standard with all transformers.
Special voltages and VA sizes available upon request.
1
Note: For 750 through 1500 VA units actual overall depth is 0.24” plus the value in column B.
* See page 10 for dimensional drawings.
All dimensions in inches
Group J
Primary Voltage: Secondary Voltage: VA
Rating
CE VA
Rating
208 x 416
12 x 24
Catalog
Number
Mtg.
Fig.
Output
Amps
200 x 400
11.5 x 23
190 x 380
11 x 22
Overall
Dimensions
A
B
Mounting
Centers
C
D
50/60 Hertz
Mounting
Slot
E
GXH
Height
with
Finger
Guard
Height
with
Fuse
Block
Adapter
Approx.
Ship
Weight
Lbs.
50
50
SP50SR
A
4.17/2.08
2.60
3.35
2.60
2.13
2.17
0.22 x 0.44
2.98
2.79
1.6
100
100
SP100SR
A
8.33/4.17
2.99
3.54
2.85
2.52
2.40
0.22 x 0.44
3.23
3.04
3.1
150
150
SP150SR
A
12.5/6.25
2.99
4.29
2.85
2.52
3.15
0.22 x 0.44
3.23
3.04
4.3
250
160
SP250SR
A
20.8/10.4
3.78
4.09
3.40
3.31
2.99
0.22 x 0.44
3.78
3.59
6.5
350
250
SP350SR
A
29.2/14.6
3.78
4.69
3.40
3.31
3.58
0.22 x 0.44
3.78
3.59
8.3
500
300
SP500SR
B
41.7/20.8
4.49
5.47
3.78
3.78
3.66
0.31 x 0.81
4.16
3.97
11
Primary and Secondary voltage links/jumpers supplied standard with all transformers.
Special voltages and VA sizes available upon request.
* See page 10 for dimensional drawings.
All dimensions in inches
Optional Accessories
Finger Guards
HPS Spartan industrial control transformers up to and including 3000VA or 30 amps are available with optional finger
guards.
Part
Number
Applicable Transformer
Part Number Suffix’s
Applicable
VA Sizes
SPFG1
AR, QR, PR, KHR, SR
50 to 500
SPFG1
KHP, SP, NJ
50 to 1500
SPFG1
ACP, MQMJ
50 to 3000
Note: Each finger guard supplies either the primary or secondary side. Finger guard option not available on
SP5000ACP and SP5000MQMJ standard units. Add 0.38” per finger guard to overall depth (column B) on
units from 50 VA to 500 VA and 0.31” to units from 750 VA to 2000 VA when finger guard has been installed.
For custom units, optional finger guards are only available on units up to 3000VA or 30 amps.
Sample Assembly Drawing for Optional
Finger Guard Installation
Finger Guard
(Only available for units supplied with either a primary or
secondary molded terminal block)
(Optional)
Fuse Block Adapter Kit
HPS Spartan industrial control transformers up to and including 3000VA or 30 amps are available with optional fuse
block adapter kits. The Fuse Block Adapter Kit is designed to allow for the installation of any third party after market
fuse block assembly onto the industrial control transformer. The transformer must be a unit that incorporates a
molded terminal block on either the primary or secondary side.
Note: HPS does not provide any jumpers or appropriate fuses for any after market fuse block you install on the HPS Spartan industrial
control transformer. The HPS Fuse Block Adapter Kit provides only the mechanical means of attaching a third party after market fuse
block. HPS does not recommend any specific fuse block or fuse supplier. For a recommended size of fuse please see page 32 of the
HTP-12 Transformer Products catalog.
Kit Part
Number
Applicable Transformer
Part Number Suffixes
Applicable
VA Sizes
SPFBAK1
AR, QR, PR, KHR, SR
50 to 500
SPFBAK1
KHP, SP, NJ
50 to 1500
SPFBAK1
ACP, MQMJ
50 to 3000
Note: Only 1 fuse block adapter kit is required per transformer. Fuse block adapter kit not available on
SP5000ACP and SP5000MQMJ standard units. Add 0.38” per fuse block adapter to overall depth (column B)
on units from 750 VA to 3000 VA when optional fuse block adapter is installed. For custom units, optional
fuse block adapter kit is only available on units up to 3000VA or 30 amps.
Fuse Block Adapter Kit
(Optional)
Sample Assembly Drawing for Optional
Fuse Block Adapter Installation
For detailed installation instructions of HPS Spartan transformers or the optional finger guards and fuse block adapter kits, please visit our
website under Products and Services - Literature & Resources - Instruction Sheets - Control Transformers.
Or go to the following link: http://www.hammondpowersolutions.com/products/product_literature/instruction_sheets/control_transformers.php
®
Dimensional Drawings
Some actual transformer units may differ from dimensional drawings shown below.
B
B
C
C
GxH
GxH
A
D
E
A
E
D
FIGURE B
FIGURE A
B
C
GxH
A
E
D
FIGURE C
B
Custom Control Capabilities
HPS is one of the industry’s most technically capable manufacturers producing the broadest and most
competitive range of custom dry-type transformers and related magnetic products in North America. Our
designs are cost effective and our transformers are built with modern manufacturing techniques. We
emphasize our Value Added Engineering whereby our design staff will interface with your team to produce
the optimum transformer. Our 3-D modelling design and CAD facilities permits quick and effective
communication when time is vital.
HPS can provide custom control transformers to fit your design style requirements for most standard or
specialty applications. From custom medium voltage to potted control, HPS has the engineering and
manufacturing resources to deliver your custom control transformer how you want it and when you need it.
Contact your HPS sales representative or the HPS sales department directly at:
[email protected]
Custom Open Core & Coil
Control
Medium Voltage Control
Enclosed Potted
Control
®
CANADA
Hammond Power Solutions Inc.
595 Southgate Drive
Guelph, Ontario N1G 3W6
Tel: (519) 822-2441
Fax: (519) 822-9701
Toll Free in Canada: 1-888-798-8882
USA
Hammond Power Solutions, Inc.
1100 Lake Street
Baraboo, Wisconsin 53913-2866
Tel: (608) 356-3921
Fax: (608) 355-7623
Toll Free in the United States: 1-866-705-4684
Email: [email protected]
Distributed by:
www.hammondpowersolutions.com
Scan this QR code with your
smartphone to view additional
information on the HPS Spartan®.
Literature No.: SPACON
Issue Date: July 2012
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement