Gallagher HBUS Modules

Gallagher HBUS Modules
Gallagher
HBUS Modules
Gallagher 8H and 4H modules support star wiring of secure high-speed HBUS devices including
T Series Readers and the F22 Fence Controller to a secure Gallagher Cabinet. I/O connectivity
is also provided for door and equipment monitoring.
Speed
The HBUS protocol runs at speeds up to 1Mb/s, substantially faster
than most other RS-485 based communications protocols. This
increased communications speed improves the response times of
HBUS devices.
Connectivity
Gallagher 8H and 4H modules allow HBUS devices to be star-wired
back to a secure controller cabinet. Star-wiring can remove the risk
of one faulty connection taking down all downstream devices as on
a daisy-chained run, and each HBUS port can also support multiple
HBUS devices.
Gallagher 8H and 4H modules have on-board inputs and outputs
that can be used for door monitoring and control, or for general I/O
functions. Gallagher 8H and 4H modules monitor and report the
state of balanced inputs, and enforce decisions to switch output
relays, if required.
Four input states are monitored (using the default two 4k7 ohm
resistors or optional configurable end-of-line resistances), including:
The on-board relays can be used for:
• Access controlled doors
• Alarm outputs, e.g. to activate sirens
• Control outputs, e.g. to switch on air conditioning
• Time activated outputs, e.g. to switch on lighting
• Open
• Short Circuit (Tamper)
Data protection
• Closed
• Open Circuit (Tamper)
All communications between the Gallagher Controller and its
connected Gallagher HBUS devices are secured using industry
leading authentication and encryption techniques. All HBUS devices
maintain a heartbeat to alert the system should any device be
taken offline and to protect against a wide range of potential attack
methods.
Inputs on the Gallagher HBUS Modules can be used to monitor:
• Access controlled doors
• Intruder detection (i.e. passive, infra-red detectors, glass break
detectors)
• Monitored doors
• Equipment alarms
• Any devices providing a clean switch contact
security.gallagher.co
Easy retrofit
Connectivity - Gallagher HBUS Modules
HBUS Modules are designed to run on all existing Controller 6000s,
allowing an easy retrofit of previous expansion modules.
To Gallagher
Controller 6000
Gallagher 8H or 4H Module
24 Inputs / 8 Outputs (8H)
12 Inputs / 4 Outputs (4H)
Gallagher cabinets
Two Gallagher Cabinets are available to accommodate the Gallagher
controllers and the Gallagher HBUS Module:
• Gallagher Single Cabinet C200100
Gallagher
T10
Reader
• Gallagher Dual Cabinet C200104
Maximum of
20 T Series
Readers
AND
25 F22 Fence
Controllers per
Gallagher
Controller 6000
HBUS RS485
Gallagher
T11 or T12
Reader
Gallagher
T10
Reader
Gallagher
T11
Reader
Gallagher
T12
Reader
Gallagher
F22 Fence
Controller
Refer to the Gallagher Cabinets data sheet for further information.
GALLAGHER HBUS Modules
JANUARY 2013
Compatibility
Gallagher Command Centre v7.05 or later
Power Supply
Voltage
13.6 v DC±15%
Current
Via Gallagher Controller 6000 connector
40mA
Via HBUS Module power in
No relays
30mA
4 relays
175mA
8 relays
315mA
If HBUS devices are connected, a maximum of 0.5 A per “V out” port is available. This additional current should be added to the Power In currents specified above.
Temperature Range
Operating Temperature
Humidity
Inputs
Outputs
-10o to +70o C
95% Noncondensing
8H Module
24
4H Module
12
8H Module
8 SPDT relays
4H Module
4 SPDT relays
Relay circuit rating
24 V DC/AC
Compliance Standards
All equipment complies with FCC, CE, C-Tick and RoHS
approvals. Please contact Gallagher for the latest list of approvals.
Part Numbers
Gallagher 4H Module
C300142
Gallagher 8H Module
C300182
Gallagher World Headquarters
Kahikatea Drive, Hamilton 3206
Private Bag 3026, Hamilton 3240
New Zealand
TEL: +64 7 838 9800
EMAIL: [email protected]
security.gallagher.co
REGIONAL OFFICES
New Zealand.................................... +64 7 838 9800
Americas....................................... +1 888 430 0770
Asia................................................ +852 2910 7912
Australia....................................... +61 2 9412 4477
India............................................ +91 80 2661 1590
Middle East........................................+9615 808728
South Africa................................. +27 11 974 4740
United Kingdom / Europe........... +44 2476 64 1234
Disclaimer: System configuration, network capacities and the
volume of system activity affect performance. Please contact
Gallagher for advice. In accordance with the Gallagher policy of
continuing development, design and specifications are subject
to change without notice. Gallagher Group Limited is an ISO
9001:2008 Certified Supplier. Copyright © Gallagher Group
Limited 2012. All rights reserved.
3E2670 – 02/13
3 A resistive, 1 A inductive
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement