Catalogue Sheet: EH Series - LED Pictogram for Hazardous Locations

Catalogue Sheet: EH Series - LED Pictogram for Hazardous Locations
new features
Type:
Project/Location:
EH SERIES
Contractor:
Prepared By:
Pictogram Sign, Hazardous
Locations: Class I Div 2,
Class II Div 1&2 and Class III
FEATURES
Date:
Model No.:
TYPICAL SPECIFICATIONS
n ∙∙ Includes the addition of Class II Div. 1&2 Groups E, F and G
as well as Class III ratings
Supply and install the Emergi-Lite® EH Series of pictogram Exit Signs. The
equipment shall be certified for Hazardous Locations: Class I Division 2
Groups A, B, C and D, Class II Divison 1&2 Groups E, F and G as well as Class
III, with the temperature code T6 (maximum 85ºC). The equipment frame
shall be of industrial grade polyvinyl chloride with a gasket around lenses and
canopy. The faceplate(s) shall be constructed of heavy-duty vandal-resistant
polycarbonate and feature an even illuminated pictogram legend. Each face
plate shall come standard with two legend films for pictogram and direction
selection. The light source shall be long-life white light-emitting diodes
(LED). The pictogram Exit Sign shall operate with universal 2-wire AC input
voltage of 120 to 347VAC at less than 2.5W and universal 2-wire DC input
voltage from 6 to 24VDC at less than 1W for single and double face signs.
The Self-powered model shall include a concealed pilot light and magnet
sensitive test switch, shall use a sealed Nickel-Cadmium battery of 2.4V
nominal voltage and shall stay illuminated during emergency operation for
at least two hours upon AC failure. The Self-powered model shall include
auto-test functions: it shall execute automatic tests for 5 minutes every
30 days, 30 minutes every 60 days and two hours annually. When a fault
is detected, the bi-colour pilot light shall turn from green to red and flash
following a particular code. The code description shall be visible on a label
next to the pilot light to identify the failure type: battery, charger circuitry,
or LED lamps. The pictogram Exit Sign shall meet or exceed the CSA 22.2
No.141-10 standard.
∙∙ Compliant Class I Division 2, Groups A, B, C and D as per
CSA C22.2 No.137-M1981
∙∙ Temperature Code T6 (maximum + 85°C) as per Canadian Electrical Code,
Part I and CSA C22.2 No.137-M1981
∙∙ High-impact thermoplastic frame with built-in gasket to secure against liquid
leaks
∙∙ Sealed, polycarbonate heavy-duty, vandal-resistant face plate(s)
∙∙ Concealed pilot light and test switch with magnetic action
∙∙ Long-life white LED light source
∙∙ Supplied standard with two pictogram films per face, for direction selection
∙∙ Meets or exceeds CSA 22.2 No.141-10 standard for pictogram Exit Signs
∙∙ Universal AC input: two-wire 120 to 347VAC; standard DC input: two-wire
6 to 24VDC
∙∙ Energy efficient – consumes less than 2.5W in AC or DC-remote mode
∙∙ Self-powered models come standard with auto-diagnostic functions
and deliver two hours of back-up legend illumination
∙∙ Suitable for cold-weather: -40°C for AC/DC and -20°C for Self-powered
models (option: -CW)
The equipment shall be Emergi-Lite® Model: _________________________ .
Made in Canada
H A Z A R D O U S LO C AT I O N FA M I LY C L A S S I , I I A N D I I I
EXHZ Combo P. 66
LPEXHZ P. 65
EHC Combo P. 68-69
HZM Battery P. 126-127
EF41 Remote P. 154
POWER CONSUMPTION
MODEL
AC SPECS
DC SPECS
AC-only
120 to 347VAC
less than 2.5W
-
-
AC/DC standard
120 to 347VAC
less than 2.5W
6 to 24VDC
less than 1W
AC/Special DC
120 to 347VAC
less than 2.5W
36, 48, 120VDC
less than 2.5W
two-wire 120V AC/DC
120VAC
less than 2.5W
120VDC
less than 2.5W
self-diagnostic
120/347VAC
less than 2.5W
nickel-cadmium battery
min. two hours
56
new
features
Type:
Project/Location:
SERIES EH
Contractor:
Prepared By:
Pictogram Sign, Hazardous
Locations: Class I Div 2,
Class II Div 1&2 and Class III
Date:
Model No.:
DIMENSIONS
Dimensions are approximate and subject to change.
4-3/8“ [11.1 cm]
4-1/4” [11.0 cm]
9-1/4” [23.4 cm]
< PICTOGRAM
LEFT FROM HERE
2-1/4” [5.7 cm]
PICTOGRAM STRAIGHT
FROM HERE
13-1/4” [33.6 cm]
PICTOGRAM >
RIGHT FROM HERE
3-1/2” [8.9 cm]
ORDERING INFORMATION
SERIES
EH= pictogram
exit sign
FACES*
1= single face
2= double face
* Ceiling or wall
mount only.
HOUSING COLOUR
G= grey
VOLTAGE
ID= s elf-powered, auto-diagnostic, non-audible,
NiCad, 120/347VAC
ID2= s elf-powered, auto-diagnostic, non-audible,
NiCad, 120/277VAC
U= universal 120 to 347VAC; 6 to 24VDC
U00= 120 to 347VAC only
U36= 120 to 347VAC; 36VDC
U48= 120 to 347VAC; 48VDC
U120= 120 to 347VAC; 120VDC
EM120-2W= 2-wires 120VAC/VDC
NEX= NEXUS® system interface, 120/347VAC*
NEX2= NEXUS® system interface, 120/277VAC*
NEXRF= w
ireless NEXUS® system interface, 120/347VAC*
NEXRF2= w
ireless NEXUS® system interface, 120/277VAC*
* Not all options available with NEXUS® System.
Please consult your sales representative
EXAMPLE: EH1GU
57
OPTIONS
CW= cold-weather (-20°C
for self-powered and
NEXUS® only)
Was this manual useful for you? yes no