C ROSS T ECHNOLOGIES, INC.

DATA SHEET

1/24/07

1582-22L2 RF Protection Switch

The 1582-22L2 RF Protection Switch provides Auto, Manual or Remote latched relay switching between CH1 and CH2 RF signals from

.95 to 2.15 GHz including 10 MHz and DC power for attached LNB or SSPB devices. Alarm conditions on CH1 and CH2 are either a contact closure to ground or an open (selectable). The logic controls two separate RF switches, X and Y. Switching logic can be selected as follows:

1. CH1 Prime Mode - Switches from CH1 to the CH2 only if CH1 alarms and CH2 is good. Switches back when CH1 no longer in alarm or both CH1 and CH2 are bad.

2. Latch to CH2 Mode - Switches to CH2 if CH1 alarms and CH2 is good. Latches to CH2. Push Manual Reset or ground Remote

Reset pin to return to CH1 if it has no alarm.

3. Minimum AUTO switching, Initial Channel Select (ICS) Mode - Switch stays on channel last selected by Manual or Remote selection after return to AUTO. AUTO switching occurs only if current channel alarms and other channel is clear.

When power is lost and when power is applied (as alarms at power up dictate), the selected channel remains on. The Manual Select switch and (when in AUTO) contact closures to Remote Select pins select CH1 or CH2 independent of alarms. LEDs indicate alarm and switch conditions for CH1 and CH2 and REMOTE or MANUAL operation. Redundant power supplies are provided.

CH1

AUTO

CH2

SWITCH

1 2 1 2

STATUS

1 2

MODEL 1582

SWITCH

C

ROSS

T

ECHNOLOGIES INC.

CH1

ONLINE

MANUAL

SELECT

CH2

ONLINE

SWITCH

RESET

MAN REM ALARM ALARM

HISTORY

HISTORY

RESET

POWER

Front Panel

EQUIPMENT SPECIFICATIONS*

Switch Characteristics

Impedance

Type

Configuration

Insertion Loss

Frequency Response

Return Loss

Isolation

75 Ω

Latching Relay

4PDT

≤ 2 dB, at 10 MHz to 25 MHz

Not Specified, 26 MHz to 0.8 GHz

1.5 dB max., ≤ 1.0 dB, typ, 0.95 to 1.5 GHz

2.5 dB max., ≤ 2.0 dB, typ, 1.5 to 2.15 GHz

≤ ±0.5 dB, any 40 MHz BW, 0.95 to 2.15 GHz

≥ 12 dB max., ≥ 14 dB, typ, 0.95 to 1.5 GHz

≥ 10 dB max., ≥ 12 dB, typ, 1.5 to 2.15 GHz

≤ -50 dB, at 10 MHz to 25 MHz

-50 dB max., ≤ -55 dB, typ, .95 to 2.15 GHz

≤ 20 milliseconds

24VDC @ 2.4 Amps; 48VDC @ 1.8 Amps

SWITCH A

SWITCHED

RF+10M+DC

SWITCH B

SWITCHED

RF+10M+DC

SWITCH C

SWITCHED

RF+10M+DC

SWITCH D

SWITCHED

RF+10M+DC

CONTROL

LOGIC

SWITCH A

RF+10M+DC 2

SWITCH A

RF+10M+DC 1

SWITCH B

RF+10M+DC 2

SWITCH B

RF+10M+DC 1

SWITCH C

RF+10M+DC 2

SWITCH C

RF+10M+DC 1

SWITCH D

RF+10M+DC 2

SWITCH D

RF+10M+DC 1

CH 1

AUTO

CH 2

Switch time

DC Switching

Controls and Indicators

Manual Select

SWITCH RESET

HISTORY RESET

LEDs (*=Closures)

REM MAN 1 2

MON

1 2

ALM

1 2

REM

REM

RESET

Manually select CH1, CH2

Resets to CH1 in latch mode, Also Resets REMOTE

Block Diagram

Resets alarm history (prior occurrence of alarms now cleared) LEDs only

CH1*, CH2* ON-LINE, ALARM, ALARM HISTORY, POWER; MANUAL*; REMOTE*

SWITCH

RESET

Other

Alarm/Remote Connector Terminal Strip

RF Connectors 75 Ω BNC (female); 50 Ω BNC, N Connectors, Optional

Mechanical 19 inch standard chassis 1.75”high X 12” deep

Power Redundant power supplies; 100-240 ± 10% VAC, 47 -63 Hz, 30 watts

*10˚C to 40˚C; 2000m max elevation; 80% max humidity; Specifications subject to change without notice.

Cross Technologies, Inc. • www.crosstechnologies.com

6170 Shiloh Road • Alpharetta, GA 30005 • 770.886.8005 • FAX 770.886.7964

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement