The 1582-22L2 RF Protection Switch provides Auto, Manual or Remote latched relay switching between CH1 and CH2 RF signals from
.95 to 2.15 GHz including 10 MHz and DC power for attached LNB or SSPB devices. Alarm conditions on CH1 and CH2 are either a contact closure to ground or an open (selectable). The logic controls two separate RF switches, X and Y. Switching logic can be selected as follows:
1. CH1 Prime Mode - Switches from CH1 to the CH2 only if CH1 alarms and CH2 is good. Switches back when CH1 no longer in alarm or both CH1 and CH2 are bad.
2. Latch to CH2 Mode - Switches to CH2 if CH1 alarms and CH2 is good. Latches to CH2. Push Manual Reset or ground Remote
Reset pin to return to CH1 if it has no alarm.
3. Minimum AUTO switching, Initial Channel Select (ICS) Mode - Switch stays on channel last selected by Manual or Remote selection after return to AUTO. AUTO switching occurs only if current channel alarms and other channel is clear.
When power is lost and when power is applied (as alarms at power up dictate), the selected channel remains on. The Manual Select switch and (when in AUTO) contact closures to Remote Select pins select CH1 or CH2 independent of alarms. LEDs indicate alarm and switch conditions for CH1 and CH2 and REMOTE or MANUAL operation. Redundant power supplies are provided.
CH1
AUTO
CH2
SWITCH
1 2 1 2
STATUS
1 2
MODEL 1582
SWITCH
C
ROSS
T
ECHNOLOGIES INC.
CH1
ONLINE
MANUAL
SELECT
CH2
ONLINE
SWITCH
RESET
MAN REM ALARM ALARM
HISTORY
HISTORY
RESET
POWER
Front Panel
EQUIPMENT SPECIFICATIONS*
Switch Characteristics
Impedance
Type
Configuration
Insertion Loss
Frequency Response
Return Loss
Isolation
75 Ω
Latching Relay
4PDT
≤ 2 dB, at 10 MHz to 25 MHz
Not Specified, 26 MHz to 0.8 GHz
1.5 dB max., ≤ 1.0 dB, typ, 0.95 to 1.5 GHz
2.5 dB max., ≤ 2.0 dB, typ, 1.5 to 2.15 GHz
≤ ±0.5 dB, any 40 MHz BW, 0.95 to 2.15 GHz
≥ 12 dB max., ≥ 14 dB, typ, 0.95 to 1.5 GHz
≥ 10 dB max., ≥ 12 dB, typ, 1.5 to 2.15 GHz
≤ -50 dB, at 10 MHz to 25 MHz
-50 dB max., ≤ -55 dB, typ, .95 to 2.15 GHz
≤ 20 milliseconds
24VDC @ 2.4 Amps; 48VDC @ 1.8 Amps
SWITCH A
SWITCHED
RF+10M+DC
SWITCH B
SWITCHED
RF+10M+DC
SWITCH C
SWITCHED
RF+10M+DC
SWITCH D
SWITCHED
RF+10M+DC
CONTROL
LOGIC
SWITCH A
RF+10M+DC 2
SWITCH A
RF+10M+DC 1
SWITCH B
RF+10M+DC 2
SWITCH B
RF+10M+DC 1
SWITCH C
RF+10M+DC 2
SWITCH C
RF+10M+DC 1
SWITCH D
RF+10M+DC 2
SWITCH D
RF+10M+DC 1
CH 1
AUTO
CH 2
Switch time
DC Switching
Controls and Indicators
Manual Select
SWITCH RESET
HISTORY RESET
LEDs (*=Closures)
REM MAN 1 2
MON
1 2
ALM
1 2
REM
REM
RESET
Manually select CH1, CH2
Resets to CH1 in latch mode, Also Resets REMOTE
Block Diagram
Resets alarm history (prior occurrence of alarms now cleared) LEDs only
CH1*, CH2* ON-LINE, ALARM, ALARM HISTORY, POWER; MANUAL*; REMOTE*
SWITCH
RESET
Other
Alarm/Remote Connector Terminal Strip
RF Connectors 75 Ω BNC (female); 50 Ω BNC, N Connectors, Optional
Mechanical 19 inch standard chassis 1.75”high X 12” deep
Power Redundant power supplies; 100-240 ± 10% VAC, 47 -63 Hz, 30 watts