Venmar Kubix HRV Plus Air Exchanger Specification Sheet
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
Venmar Kubix™ HRV Plus
Part no. 44102 (
TOP PORTS
)
Part no. 44103 (
SIDE PORTS
)
35 to 73 CFM (0.4 in. w.g.)
VB0143
THE KUBIX™ HRV PLUS: PERFECTION IN A CUBE!
The Kubix™ HRV Plus is the ideal choice for condominiums, apartments and other limited space applications that require up to 70 cfm of continuous ventilation. With its compact size and 4-inch vertical or horizontal ports, it can be installed in small spaces such as a closet or mechanical room above a hot water tank.
The Kubix™ HRV Plus has just one blower (patent pending) and is therefore quieter than any other similar HRV on the market.
• At just 30 lb. (13.6 kg), it can be installed without opening the unit
• Features pressure taps, balancing dampers, integrated hooks and
port straps to simplify installation
• Removable terminal block for quicker wall control connections
• ENERGY STAR® qualifi ed
REPAIRS AND MAINTENANCE
All parts of the Kubix™ HRV Plus that could need maintenance can be removed in less than five minutes, allowing direct access for easy repairs. The PSC motor is permanently lubricated.
WARRANTY
The Kubix™ HRV Plus is protected by a 2-year warranty on parts only.
The heat recovery core is covered by a limited lifetime warranty, with the original proof of purchase.
Available at:
HEAT RECOVERY VENTILATOR
Controls
• This unit is very simple to operate. Once it is installed, press on its
push button, located on the unit top left side, to select high speed,
low speed or to stop it (the blower is off but will turn on in response
to a wall control signal). The LED (located under the push button) will
then show on which mode the unit is in.
• The following main wall controls are available:
- Altitude programmable digital control
with SMART mode
- Deco-Touch digital control
- Lite-Touch Constructo
- Simple-Touch Constructo
- Constructo no. 40440 no. 40395 no. 40370 no. 40390 no. 40350
• Also, the following auxiliary wall controls can be added:
- 20-min. Lighted push button no. 12030
- 20/40/ 60-min. push button
- 60-min. Mechanical timer
- Dehumidistat no. 03364 no. 00910 no. 11297
For more details about controls, refer to their specifi cation sheet on www.venmar.ca.
Options
• Complete line of registers and diff users
• Exclusive wall mounting bracket no. 19255
Defrosting System
The Kubix™ HRV Plus uses a unique recirculation defrost method, which maintains balanced air pressure in the home. If there is a call for ventilation from a wall control during the defrost cycle, the defrost is put “on hold” while air is exchanged, ensuring that no humid air is recirculated.
O UTSIDE T EMPERATURE
°C °F
W
ARMER THAN
-5 W
ARMER THAN
23
-5
TO
-27 23
TO
-17
-27
AND LESS
-17
AND LESS
D EFROST C YCLE MIN ./
O PERATING MIN .
N
O DEFROST
4/20
6/15
Heat Recovery Core
Dimensions: 10” x 10” x 5.5” (25.4 cm x 25.4 cm x 14 cm)
Exchange surface: 42.3 ft.2 (3.9 m2)
Weight: 4 lb. (1.8 kg)
Material: Polypropylene
Type: Cross flow
Warranty: Limited lifetime
Requirements and standards
• Complies with the UL 1812 requirements regulating the installation
of Heat Recovery Ventilators
• Complies with the CSA C22.2 no. 113 Standard applicable to ventilators
• Complies with CSA C444 requirements regulating the installation of
• Technical data was obtained from published results of tests relating
to CSA C439 Standards
• HVI certifi ed and ENERGY STAR® qualifi ed
D
IMENSIONS
: K
UBIX
™ HRV P
LUS
(
SIDE PORTS
)
1: F
RESH AIR TO BUILDING PORT
2: E
XHAUST AIR
FROM BUILDING PORT
1
2
3 FT .
P
OWER
C
ORD
Ø 4” TYP .
16 5 /
16 ”
3 4
3: F
RESH AIR FROM OUTSIDE PORT
4: E
XHAUST AIR TO OUTSIDE PORT
100
125
150
175
200
225
15
7 /
16 ”
2 ³/
8 ”
VK0073A
19
13
/
16 ”
NOTE: A
LL UNITS PORTS WERE CREATED TO BE CONNECTED TO DUCTS HAVING A MINIMUM OF
4”
DIAMETER
,
BUT IF NEED BE
,
THEY CAN BE CONNECTED TO BIGGER SIZED DUCTS BY
USING AN APPROPRIATE TRANSITION
(
E
.
G
.: 4”
DIAMETER TO
5”
DIAMETER TRANSITION
).
15 1/
16
”
15
5
/
8
”
V
ENTILATION
P
ERFORMANCE
E
XTERNAL
S
TATIC
P
RESSURE
N
ET
S
UPPLY
A
IR
F
LOW
S
UPPLY
G
ROSS
A
IR
F
LOW
E
XHAUST
P
A IN
.
W
.
G
.
L
/
S CFM M
3/
H L
/
S CFM M
3/
H L
/
S CFM M
3/
H
25
50
75
0.1
0.2
0.3
40 84 143 40 85
38 80 136 38 81
36 77 131 37 78
144 40 85
138 38 81
133 37 79
144
138
134
K
UBIX
15 7 /
16
”
™ HRV P
2
3
LUS
(
TOP PORTS
)
1
1: F
RESH AIR TO BUILDING PORT
2: E
XHAUST AIR FROM BUILDING PORT
3: F
RESH AIR FROM OUTSIDE PORT
4: E
XHAUST AIR TO OUTSIDE PORT
4
0.4
0.5
0.6
0.7
0.8
0.9
34 73 124 35 73
33 70 119 33 71
31 65 110 31 66
29 60 102 29 61
26 56 95 27 57
25 52 88 25 53
124 35 74
121 34 71
112 32 68
104 29 62
97 27 57
90 25 52
126
121
116
105
97
88
3
FT
.
P
OWER
C
ORD
E
NERGY
P
ERFORMANCE
S
UPPLY
T
EMPERATURE
N
ET
A
IR
F
LOW
°C °F
L
/
S CFM M
3/
H
H
EATING
0
0
P
OWER
CONSUMED
WATTS
32 20 42 71 36
32 30 64 109 52
S ENSIBLE
RECOVERY
EFFICIENCY
67
61
• Part Number Side Ports: 44103
• Total Assembled Weight (including
polypropylene core): 30 lb. (13.6 kg)
• Round 4” ports
• Drain: 1/2” (1.2 cm) fi tting with
10 ft. (3 m) PVC drain hose
• Core Filters: 2 washable foam fi lters,
9.2” x 5.75” x 0.38”
(23.4 cm x 16.6 cm x 1 cm)
A
PPARENT
SENSIBLE
EFFECTIVENESS
77
71
L
ATENT RECOVERY
/
MOISTURE
TRANSFER
0.00
0.00
Ø
4”
TYP
.
18 5 /
8
”
16 5 /
16
”
0 32 38 81 138 54
-25 -13 18 39 66 42
58
60
65
81
0.00
0.02
-25 -13 30 64 109 53
C
OOLING
55 70
T
OTAL
R
ECOVERY
E
FFICIENCY
0.01
35 95 -
NOTE: All specifi cations are subject to change without notice.
S
PECIFICATIONS
• Model: Kubix™ HRV Plus
• Part Number Top Ports: 44102
VK0074A
• Housing: Pre-painted steel
• Insulation: Expanded polystyrene
15 1 /
16
”
15 5 /
8
”
2 3 / 8
”
NOTE: A
LL UNITS PORTS WERE CREATED
TO BE CONNECTED TO DUCTS
HAVING
4”
A MINIMUM OF
,
BUT IF NEED BE
,
THEY CAN BE CONNECTED
TO BIGGER SIZED DUCTS BY
USING AN APPROPRIATE
TRANSITION
TO
(
E
.
G
.: 4”
DIAMETER
5”
DIAMETER TRANSITION
).
• Mounting: Suspension by chains and spring or optional wall bracket
• Speed Control on Unit:
- Low speed and high speed
- Other modes available
with auxiliary wall controls
• Heat Recovery Core:
- Heat Exchange Surface Area: 42.3 ft.
2 (3.9 m2)
- Type: Crossfl ow
• Supply and Exhaust Blower Motor: 1 motor - Material: Polypropylene
- Protection type: Thermally protected
- Insulation class: B
• Unit Electrical Characteristics:
Volts Frequency Ampere Watts
120 60 Hz 0.5 60
Project:
Location:
Part no.:
Qty.:
Submitted by: Date:
REMARKS
Residential Products Group, 550 Lemire Blvd., Drummondville, Qc, Canada J2C 7W9 - Tel.: 1-800-567-3855 Fax: 1-800-567-1715 www.venmar.ca KubixHRVPlusd131203