Venmar Kubix HRV Plus Air Exchanger Specification Sheet

Venmar Kubix HRV Plus Air Exchanger Specification Sheet

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

Manual
Venmar Kubix HRV Plus Air Exchanger Specification Sheet | Manualzz

Venmar Kubix™ HRV Plus

Part no. 44102 (

TOP PORTS

)

Part no. 44103 (

SIDE PORTS

)

35 to 73 CFM (0.4 in. w.g.)

VB0143

THE KUBIX™ HRV PLUS: PERFECTION IN A CUBE!

The Kubix™ HRV Plus is the ideal choice for condominiums, apartments and other limited space applications that require up to 70 cfm of continuous ventilation. With its compact size and 4-inch vertical or horizontal ports, it can be installed in small spaces such as a closet or mechanical room above a hot water tank.

The Kubix™ HRV Plus has just one blower (patent pending) and is therefore quieter than any other similar HRV on the market.

• At just 30 lb. (13.6 kg), it can be installed without opening the unit

• Features pressure taps, balancing dampers, integrated hooks and

port straps to simplify installation

• Removable terminal block for quicker wall control connections

• ENERGY STAR® qualifi ed

REPAIRS AND MAINTENANCE

All parts of the Kubix™ HRV Plus that could need maintenance can be removed in less than five minutes, allowing direct access for easy repairs. The PSC motor is permanently lubricated.

WARRANTY

The Kubix™ HRV Plus is protected by a 2-year warranty on parts only.

The heat recovery core is covered by a limited lifetime warranty, with the original proof of purchase.

Available at:

HEAT RECOVERY VENTILATOR

Controls

• This unit is very simple to operate. Once it is installed, press on its

push button, located on the unit top left side, to select high speed,

low speed or to stop it (the blower is off but will turn on in response

to a wall control signal). The LED (located under the push button) will

then show on which mode the unit is in.

• The following main wall controls are available:

- Altitude programmable digital control

with SMART mode

- Deco-Touch digital control

- Lite-Touch Constructo

- Simple-Touch Constructo

- Constructo no. 40440 no. 40395 no. 40370 no. 40390 no. 40350

• Also, the following auxiliary wall controls can be added:

- 20-min. Lighted push button no. 12030

- 20/40/ 60-min. push button

- 60-min. Mechanical timer

- Dehumidistat no. 03364 no. 00910 no. 11297

For more details about controls, refer to their specifi cation sheet on www.venmar.ca.

Options

• Complete line of registers and diff users

• Exclusive wall mounting bracket no. 19255

Defrosting System

The Kubix™ HRV Plus uses a unique recirculation defrost method, which maintains balanced air pressure in the home. If there is a call for ventilation from a wall control during the defrost cycle, the defrost is put “on hold” while air is exchanged, ensuring that no humid air is recirculated.

O UTSIDE T EMPERATURE

°C °F

W

ARMER THAN

-5 W

ARMER THAN

23

-5

TO

-27 23

TO

-17

-27

AND LESS

-17

AND LESS

D EFROST C YCLE MIN ./

O PERATING MIN .

N

O DEFROST

4/20

6/15

Heat Recovery Core

Dimensions: 10” x 10” x 5.5” (25.4 cm x 25.4 cm x 14 cm)

Exchange surface: 42.3 ft.2 (3.9 m2)

Weight: 4 lb. (1.8 kg)

Material: Polypropylene

Type: Cross flow

Warranty: Limited lifetime

Requirements and standards

• Complies with the UL 1812 requirements regulating the installation

of Heat Recovery Ventilators

• Complies with the CSA C22.2 no. 113 Standard applicable to ventilators

• Complies with CSA C444 requirements regulating the installation of

• Technical data was obtained from published results of tests relating

to CSA C439 Standards

• HVI certifi ed and ENERGY STAR® qualifi ed

D

IMENSIONS

: K

UBIX

™ HRV P

LUS

(

SIDE PORTS

)

1: F

RESH AIR TO BUILDING PORT

2: E

XHAUST AIR

FROM BUILDING PORT

1

2

3 FT .

P

OWER

C

ORD

Ø 4” TYP .

16 5 /

16 ”

3 4

3: F

RESH AIR FROM OUTSIDE PORT

4: E

XHAUST AIR TO OUTSIDE PORT

100

125

150

175

200

225

15

7 /

16 ”

2 ³/

8 ”

VK0073A

19

13

/

16 ”

NOTE: A

LL UNITS PORTS WERE CREATED TO BE CONNECTED TO DUCTS HAVING A MINIMUM OF

4”

DIAMETER

,

BUT IF NEED BE

,

THEY CAN BE CONNECTED TO BIGGER SIZED DUCTS BY

USING AN APPROPRIATE TRANSITION

(

E

.

G

.: 4”

DIAMETER TO

5”

DIAMETER TRANSITION

).

15 1/

16

15

5

/

8

V

ENTILATION

P

ERFORMANCE

E

XTERNAL

S

TATIC

P

RESSURE

N

ET

S

UPPLY

A

IR

F

LOW

S

UPPLY

G

ROSS

A

IR

F

LOW

E

XHAUST

P

A IN

.

W

.

G

.

L

/

S CFM M

3/

H L

/

S CFM M

3/

H L

/

S CFM M

3/

H

25

50

75

0.1

0.2

0.3

40 84 143 40 85

38 80 136 38 81

36 77 131 37 78

144 40 85

138 38 81

133 37 79

144

138

134

K

UBIX

15 7 /

16

™ HRV P

2

3

LUS

(

TOP PORTS

)

1

1: F

RESH AIR TO BUILDING PORT

2: E

XHAUST AIR FROM BUILDING PORT

3: F

RESH AIR FROM OUTSIDE PORT

4: E

XHAUST AIR TO OUTSIDE PORT

4

0.4

0.5

0.6

0.7

0.8

0.9

34 73 124 35 73

33 70 119 33 71

31 65 110 31 66

29 60 102 29 61

26 56 95 27 57

25 52 88 25 53

124 35 74

121 34 71

112 32 68

104 29 62

97 27 57

90 25 52

126

121

116

105

97

88

3

FT

.

P

OWER

C

ORD

E

NERGY

P

ERFORMANCE

S

UPPLY

T

EMPERATURE

N

ET

A

IR

F

LOW

°C °F

L

/

S CFM M

3/

H

H

EATING

0

0

P

OWER

CONSUMED

WATTS

32 20 42 71 36

32 30 64 109 52

S ENSIBLE

RECOVERY

EFFICIENCY

67

61

• Part Number Side Ports: 44103

• Total Assembled Weight (including

polypropylene core): 30 lb. (13.6 kg)

• Round 4” ports

• Drain: 1/2” (1.2 cm) fi tting with

10 ft. (3 m) PVC drain hose

• Core Filters: 2 washable foam fi lters,

9.2” x 5.75” x 0.38”

(23.4 cm x 16.6 cm x 1 cm)

A

PPARENT

SENSIBLE

EFFECTIVENESS

77

71

L

ATENT RECOVERY

/

MOISTURE

TRANSFER

0.00

0.00

Ø

4”

TYP

.

18 5 /

8

16 5 /

16

0 32 38 81 138 54

-25 -13 18 39 66 42

58

60

65

81

0.00

0.02

-25 -13 30 64 109 53

C

OOLING

55 70

T

OTAL

R

ECOVERY

E

FFICIENCY

0.01

35 95 -

NOTE: All specifi cations are subject to change without notice.

S

PECIFICATIONS

• Model: Kubix™ HRV Plus

• Part Number Top Ports: 44102

VK0074A

• Housing: Pre-painted steel

• Insulation: Expanded polystyrene

15 1 /

16

15 5 /

8

2 3 / 8

NOTE: A

LL UNITS PORTS WERE CREATED

TO BE CONNECTED TO DUCTS

HAVING

4”

A MINIMUM OF

,

BUT IF NEED BE

,

THEY CAN BE CONNECTED

TO BIGGER SIZED DUCTS BY

USING AN APPROPRIATE

TRANSITION

TO

(

E

.

G

.: 4”

DIAMETER

5”

DIAMETER TRANSITION

).

• Mounting: Suspension by chains and spring or optional wall bracket

• Speed Control on Unit:

- Low speed and high speed

- Other modes available

with auxiliary wall controls

• Heat Recovery Core:

- Heat Exchange Surface Area: 42.3 ft.

2 (3.9 m2)

- Type: Crossfl ow

• Supply and Exhaust Blower Motor: 1 motor - Material: Polypropylene

- Protection type: Thermally protected

- Insulation class: B

• Unit Electrical Characteristics:

Volts Frequency Ampere Watts

120 60 Hz 0.5 60

Project:

Location:

Part no.:

Qty.:

Submitted by: Date:

REMARKS

Residential Products Group, 550 Lemire Blvd., Drummondville, Qc, Canada J2C 7W9 - Tel.: 1-800-567-3855 Fax: 1-800-567-1715 www.venmar.ca KubixHRVPlusd131203