Do-more T1H PLC Technical Specs

Prices as of April 15, 2015. Check Web site for most current prices. Do-more T1H Series PLC System Specifications General Specifications General Specifications Ambient Operating Temperature 32°F to 131°F (0°C to 55°C) Storage Temperature -4°F to 158°F (-20°C to 70°C) Ambient Humidity 5% to 95% (Non-condensing) Atmosphere No corrosive gases. The level of environmental pollution = 2 (UL 840) Vibration Resistance MIL STD 810C, Method 514.2 Shock Resistance MIL STD 810C, Method 516.2 Voltage Withstand (Dielectric) 1500 VAC, 1 minute Insulation Resistance 500 VDC, 10 Mq Noise Immunity NEMA ICS3-304 Impulse noise 1µs, 1000 V FCC class A RFI (144 MHz, 430 MHz 10 W, 10 cm) Agency Approvals UL E185989, CE, FCC class A, NEC Class 1 Division 2 Book 1 (14.3) eDT-14 Do-more T1H PLCs 1-800-633-0405 Prices as of April 15, 2015. Check Web site for most current prices. Do-more T1H Series PLC System Specifications Module Placement and I/O Usage Tables There are no I/O module placement restrictions with the Do-more T1H Series PLC family. In general, any mix of up to 16 analog and discrete I/O module types can be used in any local or Ethernet I/O base. Specialty modules can also be used in any local or Ethernet I/O base. Reference the Module Placement Restrictions table to the right for the Do-more T1H Series PLC. Company Information Control Systems Overview CLICK PLC Module Placement Restrictions Do-More PLCs Module/Unit Local CPU Base Ethernet I/O Base CPUs Discrete I/O Analog I/O CPU slot only 3 3 3 3 Do-More T1H PLC CPU slot only DirectLOGIC PLCs Overview 3 DirectLOGIC DL05/06 Base Controller T1H-EBC100 Specialty Module T1H-CTRIO 3 Do-More H2 PLC DirectLOGIC DL105 Analog I/O in the Ethernet I/O bases When using an analog module in an Ethernet I/O base, the analog update time to the CPU will be asynchronous to the scan time. Critical analog I/O should be located in the local base. I/O point usage The table to the right indicates the number of I/O points consumed by each module. These X (discrete input), Y (discrete output), WX (analog input) and WY (analog output) addresses are automatically assigned by Do-more Designer. DirectLOGIC DL205 DirectLOGIC DL305 I/O Module Point Usage DC INPUT T1K-08ND3 T1K-16ND3 8X 16 X RELAY OUTPUT SPECIALTY MODULES T1K-08TR T1K-16TR T1K-08TRS T1H-CTRIO 8Y 16 Y 8Y None Productivity Controller Productivity 3000 AC INPUT T1K-08NA-1 T1K-16NA-1 8X 16 X DC OUTPUT T1K-08TD1 T1K-16TD1 T1K-08TD2-1 T1K-16TD2-1 T1H-08TDS AC OUTPUT T1K-08TA T1K-16TA T1K-08TAS Universal Field I/O ANALOG 8Y 16 Y 8Y 16 Y 8Y 8Y 16 Y 8Y DirectLOGIC DL405 T1F-08AD-1 T1F-08AD-2 T1F-16AD-1 T1F-16AD-2 T1F-16RTD T1F-14THM T1F-08DA-1 T1F-08DA-2 T1F-16DA-1 T1F-16DA-2 T1F-8AD4DA-1 T1F-8AD4DA-2 Software 8 X, 8 WX 8 X, 8 WX 16 X, 16 WX 16 X, 16 WX 16 X, 16 WX 16 X, 16 WX 8 Y, 8 WY 8 Y, 8 WY 8 Y, 16 WY 8 Y, 16 WY 8 X, 8 WX/8 Y, 4 WY 8 X, 8 WX/8 Y, 4 WY C-More HMI C-More Micro HMI ViewMarq Industrial Marquees Other HMI Communications Appendix Book 1 Terms and Conditions Book 1 (14.3) www.automationdirect.com/do-more-plcs Do-more T1H PLCs eDT-15 Prices as of April 15, 2015. Check Web site for most current prices. Do-more T1H Series PLC System Specifications Power supplies Power requirements The T1H Series PLC offers two power supply options: AC or DC. More than one power supply can be installed in a T1H series PLC system with each power supply positioned to the left of the modules they supply power to. Module 5VDC 24VDC CPU Modules DC Output Modules $111.00 200 0 T1F-08AD-1 75 50* T1H-DM1E 275 0 T1K-08TD1 100 200* T1F-08AD-2 75 50* T1K-16TD1 200 400* T1F-16AD-1 75 50* T1K-08TD2-1 100 0 T1F-16AD-2 75 50* T1K-16TD2-1 200 0 T1F-14THM 60 70* T1F-16RTD 150 0 300 0 T1K-08ND3 35 0 AC Output Modules T1K-16ND3 70 0 T1K-08TA 250 0 Analog Output Modules T1K-16TA 450 0 T1F-08DA-1 75 150* 300 0 T1F-08DA-2 75 150* AC Input Modules T1K-08NA-1 35 0 T1K-08TAS T1K-16NA-1 70 0 Relay Output Modules 75 150* 350 0 T1F-16DA-2 75 150* T1K-16TR 700 0 Combination Analog Modules T1K-08TRS 400 0 T1F-8AD4DA-1 75 60* T1F-8AD4DA-2 75 70* Specialty Module T1K-01DC T1K-01AC T1F-16DA-1 T1K-08TR T1H-CTRIO Calculating the power budget Input Frequency 50/60 Hz N/A Maximum Power 50 VA 30 W To calculate the power budget, read the available power (current rating) from the Power Supply Specifications table and subtract the power consumed by each module to the right of the power supply. Do not include modules to the right of an additional power supply. 10 A Insulation Resistance > 10 Mq @ 500 VDC Voltage Withstand 1 min. @ 1500 VAC between primary, secondary and field ground Voltage 5.25 VDC 5.25 VDC mA max 5VDC Current Rating 2000 (see the table 2000 mA max PWR below) Ripple 5% max. 5% max. Voltage 24 VDC N/A mA max. 24VDC Current Rating 500 (see the table N/A PWR below) Ripple 10% max. 400 0 * Use either internal or external source for 24VDC Input Voltage Range 110/220 VAC 12/24 VDC Max. Inrush Current 20 A Analog Input Modules T1H-08TDS Power supply specifications Power Supply Specifications 5VDC 24VDC 0 DC Input Modules $116.00 Module 250 T1H-EBC100 T1K-01DC 5VDC 24VDC T1H-DM1 Interface Module T1K-01AC Module Adding additional power supplies Each power supply furnishes power only to the modules to its right. Inserting a second power supply closes the power loop for the power supply to the left, while also powering the modules to its right. Perform a power budget calculation for each power supply in the system. * Use either internal or external source for 24VDC Power Budget Example Module 5VDC 24VDC T1K-01AC +2000 mA +300 mA T1H-DM1E -275 mA -0 mA T1K-16ND3 -70 mA -0 mA T1K-16TD2-1 -200 mA -0 mA T1F-08AD-1 -75 mA -50 mA Remaining +1380 mA +250 mA Accessories available for Terminator I/O are listed in the Terminator Field I/O section of the Price List N/A Fuse 1 (primary), not replaceable MVSTBW MVSTBW Replacement 2.5/4-ST-5.08 2.5/6-ST-5.08 Terminal Block BK BK (Phoenix Contact) T1H-DM1E TERM RUN I/O ERR RUN STOP USB TX RX USB PGM PORT T1K-01AC Current Output 5VDC PWR 2000 mA 1500 mA 24VDC PWR 300 mA 500 mA Note: 500 mA @ 24VDC can be achieved by lowering the 5 VDC from 2000 mA to 1500 mA. Book 1 (14.3) eDT-16 Do-more T1H PLCs This power supply powers the CPU module and the next two I/O modules This power supply powers these three I/O modules 1-800-633-0405 Prices as of April 15, 2015. Check Web site for most current prices. CPU Modules Company Information Control Systems Overview CLICK PLC Specifications Feature Total Memory (bytes) Ladder Memory (instruction words) V-Memory (words) Non-volatile V Memory (words) D-memory (DWORDs) Non-volatile D Memory (DWORDs) R-memory (REAL DWORDs) Non-volatile R Memory (REAL DWORDs) Boolean execution Stage Programming T1H-DM1 $359.00 262,144 bytes 65,536 instruction words Configurable up to 65536 (4096 default) Configurable up to 65536 (4096 default) Configurable up to 65536 (4096 default) Configurable up to 65536 (4096 default) Configurable up to 65536 (4096 default) Configurable up to 65536 (4096 default) 50 uSec Yes 128 per Program code-block; number of code-blocks configurable to memory limit Handheld Programmer Programming Software for Windows No FREE Do-more Designer version 1.2 or newer USB, RS-232, USB, RS-232 Ethernet (10/100 Base-T) Flash ROM X, Y, each configurable up to 65536 (2048 default); WX, WY (analog in/out) each configurable up to 65536 (256 default) Built-In communications ports Program Memory Total I/O points available 16 256 131,072 32,768 32,768 Configurable up to 65536 (2048 default) ASCII PID Loop Control, Built In Time of Day Clock/Calendar Run Time Edits Supports True Force Internal Diagnostics Password security System error log User error log Battery backup >170 1024 512 Configurable up to 65536 (256 default) Configurable up to 65536 (256 default) 8 Configurable up to 65536 (32 default) Configurable up to memory limit (192 default) Yes, configurable up to memory limit, default 1024 input bits, 1024 coil bits, 2048 input registers, 2048 holding registers Up to memory limit, default 512 X, 512 Y, 512 C, 2048 V No No Program and Task code-blocks, up to memory limit Yes, up to memory limit Yes FOR/NEXT, WHILE/WEND, REPEAT/UNTIL loops >60 operators and functions: Integer, Floating Point, Trigonometric, Statistical, Logical, Bitwise, Timing Yes, IN/OUT, Serial, Ethernet TCP and UDP; 11 output script commands Yes, configurable to memory limit (over 2,000) Yes Yes Yes Yes Multi-user, credentialed, session-based security Yes Yes Yes (Battery included) Book 1 (14.3) www.automationdirect.com/do-more-plcs Do-more T1H PLCs DirectLOGIC PLCs Overview DirectLOGIC DL105 DirectLOGIC DL205 DirectLOGIC DL305 DirectLOGIC DL405 Universal Field I/O 8/16 Control relays Special relays (system defined) Special registers (system defined) Timers Counters System Date/Time structures User Date/Time structures ASCII String/Byte buffer structures Math Do-More T1H PLC Productivity 3000 16 >160 DL Classic Client memory Immediate I/O Interrupt input (hardware / timed) Subroutines Drum Timers Table Instructions Loops Do-More H2 PLC Productivity Controller Number of instructions available Modbus Client memory Do-More PLCs DirectLOGIC DL05/06 Number of Stages Max Number of Local I/O Modules Local I/O points available Ethernet I/O Discrete points Ethernet I/O Analog I/O Channels Max Number of Ethernet slaves per PLC I/O points on Ethernet I/O Discrete I/O Module Point Density T1H-DM1E $459.00 T1H-DM1E T1H-DM1 eDT-17 Software C-More HMI C-More Micro HMI ViewMarq Industrial Marquees Other HMI Communications Appendix Book 1 Terms and Conditions Prices as of April 15, 2015. Check Web site for most current prices. CPU Modules T1H-DM1 T1H-DM1E USB 2.0 Port (Type B) - Programming RS 232 Serial Port (RJ12) - Programming - Multipurpose Serial Communications Port 10/100 MB Ethernet Port (RJ45) - Programming - Modbus TCP Client and Server - Ethernet I/O Master ACTIVITY Y RS232 SERIAL PORT RS232 SERIAL PORT ) er er 100 MBIT 10/100 BASE-T ETHERNET PORT LED Status Indicators T1H-DM1E LED Indicators Indicator RUN ROM ACTIVITY Y 100 MBIT ERR USB RS232 SERIAL PORT 10/100 BASE-T ETHERNET PORT TX RX ACTIVITY 100 MBIT Status Description Green CPU is in RUN Mode Yellow Forces are Active Yellow Red Yellow CPU is updating Non-volatile Memory CPU Fatal Error Low Battery Green Status OK (good) Green USB Receive Activity Yellow USB Transmit Activity Green RS-232 Transmit Activity Green RS-232 Receive Activity Green Ethernet Port Activity Yellow Ethernet Port communicating at 100 MBIT Rate PLC Mode Switch T1H-DM1E Mode Switch Functions Mode Switch Position CPU Action RUN (Run Program) CPU is forced into RUN Mode if no errors are encountered. TERM (Terminal) RUN, PROGRAM and DEBUG modes are available. In this switch position, the mode of operation can be changed through the Programming Software. STOP (Stop Program) CPU is forced into STOP Mode. Book 1 (14.3) eDT-18 Do-more T1H PLCs 1-800-633-0405 Prices as of April 15, 2015. Check Web site for most current prices. CPU Modules Company Information Control Systems Overview CLICK PLC Communication Ports Do-More PLCs USB Port Do-More H2 PLC Used exclusively for programming and monitoring via a PC running Do-more Designer. Do-More T1H PLC USB Port Specifications DirectLOGIC PLCs Overview Description Standard USB 2.0 Slave input for programming and online monitoring, with built-in surge protection. Not compatible with older full speed USB devices. DirectLOGIC DL05/06 Cables USB Type A to USB Type B: DirectLOGIC DL105 (ADC part #) USB-CBL-AB3 (3 ft.) DirectLOGIC DL205 USB-CBL-AB6 (6 ft.) USB-CBL-AB10 (10 ft.) USB-CBL-AB15 (15 ft.) DirectLOGIC DL305 Pin DirectLOGIC DL405 Description 1 2 3 4 5V Bus Voltage Sense D- Data - D+ Data + 0V Ground Productivity Controller Productivity 3000 Universal Field I/O RS-232 Port RJ-12 style connector used for: • Connection to a PC running Do-more Designer • Modbus RTU Master connections • Modbus RTU Slave connections • ASCII Incoming and Outgoing communications • Custom Protocol Incoming and Outgoing communications Software RS-232 Port Specifications Description Non-isolated, full duplex RS-232 DTE port used for programming, online monitoring or can connect the CPU as a Modbus RTU or ASCII master or slave to a peripheral device. Includes ESD and built-in surge protection. 1200, 2400, 4800, 9600, 19200, 38400, 57600, and 115200 Baud Rates +5V Cable Power Source Maximum Output Load (TXD/RTS) Minimum Output Voltage Swing Output Short Circuit Protection Cable Options 220 mA maximum at 5V, +/- 5%. Reverse polarity and overload protected. (ADC part #) USB-RS232 with D2-DSCBL 3 KV, 1,000 pf +/-5V Other HMI +/-15 mA Communications D2-DSCBL Appendix Book 1 Terms and Conditions FA-ISOCON for converting RS-232 to isolated RS-422/485 EA-MG-PGM-CBL 1 2 3 4 5 6 C-More Micro HMI ViewMarq Industrial Marquees FA-CABKIT Pin C-More HMI Description 0V Power (-) connection (GND) 5V Power (+) connection (220 mA max.) RXD Receive Data (RS-232) TXD Transmit Data (RS-232) RTS Request to Send (RS-232) CTS Clear to Send (RS-232) For a list of protocols supported by each port, please refer to the Communications topic of the Do-more T1H Series PLC Overview in this section. Book 1 (14.3) www.automationdirect.com/do-more-plcs Do-more T1H PLCs eDT-19 Prices as of April 15, 2015. Check Web site for most current prices. CPU Modules Ethernet Port RJ-45 style connector used for: • Connection to a PC running Do-more Designer • Modbus TCP Client connections (Modbus requests sent from the CPU) • Modbus TCP Server connections (Modbus requests received by the CPU) • Ethernet I/O Master Ethernet Port Specifications Description Standard transformer isolated Ethernet port with built-in surge protection for programming, online monitoring, Modbus/TCP client/server connections (fixed IP or DHCP) and Ethernet I/O capabilities. Transfer Rate 10/100 Mbps Cables Use a Patch (Point to Point) cable when a switch or hub is used. Use a Crossover cable when a switch or hub is not used. 8 1 For a list of protocols supported by each port, please refer to the Communications topic of the Do-more T1H Series PLC Overview in this section. Battery Specifications DIP Switch Specifications A battery is included with the Do-more CPU and is used to retain the Time and Date along with any Tagname values that are set up as retentive. It is recommended that the battery be replaced once every five years or when one year of cumulative OFF time has been exceeded. The T1H Series Do-more CPU also comes equipped with a set of eight DIP switches (0-7) that can be used to affect the boot sequence of the controller. The default position for all of the DIP switches is OFF. At least two hours is allowed to change out a battery without loss of data. T1H-DM1 and T1H-DM1E Battery Replacement Part # D0-MC-BAT 7 6 5 4 3 2 1 0 ON Battery Coin type, 3.0V D0-MC-BAT Lithium battery, number CR2032 $3.00 Book 1 (14.3) eDT-20 Do-more T1H PLCs 1-800-633-0405 Prices as of April 15, 2015. Check Web site for most current prices. CPU Modules Company Information Control Systems Overview CLICK PLC Ethernet I/O The T1H-DM1E CPU’s built-in Ethernet port can be configured as an Ethernet I/O master. The Ethernet I/O feature allows expansion beyond the local base to slave I/O using the onboard high-speed Ethernet link. The onboard Ethernet port can support up to 16 slave devices. The slave I/O modules supported are: • H2-EBC100 • T1H-EBC100 (Terminator I/O) • GS-EDRV100 (GS Drives) Do-More PLCs The Ethernet I/O network uses Category 5 UTP cables for cable runs up to 100 meters (328 ft.) with extended distances achieved through Ethernet switches. Do-More H2 PLC Do-More T1H PLC It is highly recommended that a dedicated network be used with the Ethernet I/O feature. Ethernet I/O networks and ECOM/office networks should be isolated from one another to prevent network delays. DirectLOGIC PLCs Overview DirectLOGIC DL05/06 DirectLOGIC DL105 Stride Ethernet Switch DirectLOGIC DL205 DirectLOGIC DL305 Do-more T1H-DM1E CPU DirectLOGIC DL405 T1H-DM1E TERM RUN I/O ERR RUN STOP USB TX RX USB PGM PORT Productivity Controller Productivity 3000 DirectLOGIC DL205 I/O with H2-EBC100 Module C-more Operator Interface Universal Field I/O Software C-More HMI GS-EDRV100 C-More Micro HMI Terminator I/O with T1H-EBC100 Module ViewMarq Industrial Marquees Other HMI Communications GS Drive Appendix Book 1 Terms and Conditions Book 1 (14.3) www.automationdirect.com/do-more-plcs Do-more T1H PLCs eDT-21 Prices as of April 15, 2015. Check Web site for most current prices. Do-more T1H Series PLC Overview Company Information Control Systems Overview Do-more T1H Series PLC Hardware User Manual (T1H-DM-M) CLICK PLC Do-more T1H Series PLC Hardware User Manual is available as a free download from Automationdirect. com. A hard copy is also available for purchase. Do-More PLCs Do-More H2 PLC Do-more Designer (Part No. DM-PGMSW) Do-More T1H PLC Do-more Designer is the full-featured programming software for the Do-more PLC series. Do-more Designer is a free download from Automationdirect.com. A CD-ROM version is also available for purchase for $10.00. DirectLOGIC PLCs Overview 1.2 DirectLOGIC DL05/06 DirectLOGIC DL105 DirectLOGIC DL205 Start Page DirectLOGIC DL305 When the software is started, the Start Page is displayed. This page contains a Launchpad with Projects, Applications and Links windows. It also contains shortcuts to important help file topics, and you can start the Do-more Simulator from this page. DirectLOGIC DL405 Productivity Controller Productivity 3000 Universal Field I/O Launchpad Software C-More HMI C-More Micro HMI ViewMarq Industrial Marquees Do-more Simulator Help File Shortcuts Other HMI Communications Main Programming Window Project Toolbar Project Browser The Main Programming Window is displayed when a new project is started or an existing project is opened. It is divided into Menus, Toolbars, and Windows that work together to make project development simple. Ladder View Ladder Palette Bar Book 1 (14.3) www.automationdirect.com/do-more-plcs Do-more T1H PLCs eDT-9 Appendix Book 1 Terms and Conditions
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
Related manuals
Download PDF
advertisement