Revox Re:connect M200 Mk2 Domotic Interface Bedienungsanleitung
Below you will find brief information for Domotic Interface Re:connect M200 Mk2. The Re:connect M200 Mk2 Domotic Interface is a device designed to allow you to control Pioneer plasma and LCD TVs from your Revox system. It can be used to select the correct video input on the TV, as well as to control some of the TV's functions from the Revox system. The M200 Mk2 can be connected not only to an M51 but also to the M219 Side room amplifier. This allows you to control the Pioneer TV from a side room using the M219 Side room amplifier.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
of
of
Re:connect
M200 Mk2
Domotic Interface
Pioneer
Dominating Entertainment.
Revox of Switzerland
.
E
2.00
Introduction M200 Mk2
Attention M200 Mk2
Mozilla Firefox.lnk
The Mk2 version has a new Atmega 644 processor, which has a larger memory. Software version 2.00 can only be installed on the M200
Mk2. If you have an M200 Mk1 with the Atmega-163/ -16 processor, you can upgrade this to the current Mk2 version with the Upgrade Kit.
After updating the M209 firmware to version 2.00 or higher, we recommend completely resetting the M200 interface by pressing the
Disable
softkey on setup page #5 for several seconds, until setup page
#1 automatically appears. Please refer also to page 13 ff.
Introduction
M200 - New features
- Switching between stations
- Function overview
Installation
Connection
M51 Link IN/ OUT
RS
Trigger Input: Input A/ B
Relay A/ B
Voltage ramp 0-10V
IR-LINK
Setup Button
Setup
#1
– Trigger input
Setup
Setup
#4
– Relay
– IR Address/ Source
– Slot/ Serial Port Mode
Serial Interface
Link
RS-232
Video Controller
Connection plan with
Pioneer-TV M219
Gefen HDMI Switcher with M51
Gefen HDMI Switcher with M219
Overview Video products
Gefen HDMI Switcher 4x1/ 4x2 / 6x2
Pioneer Models (Plasma & LCD)
Setup #5 AV Assignment
Assigning audio source
Smart audio sources
Assigning video sources
#5
Setup #5 Reset Assignment
Guarantee
Included in delivery
Technical data
Wiring the M200 interface
M200 Mk2
Introduction
Introduction
Introduction
1
4
4
5
3
3
2
2
14
14
14
15
16
17
17
18-20
6-7
8
6
6
9-12
12
12
12
13
21
21
22
23
24
25
25
26
26
27
28
Introduction
M200 Pioneer
With the Re:connect M200 Pioneer, Revox offers an interface, for the intelligent control of the most widely used Pioneer plasma and LCD devices*.
The correct picture input is automatically selected at the television with the help of the interface. Additionally, the next or previous TV programme can be selected for the television, through the M218 wall-mounted keypad.
*Please observe the system requirements
New Multiroom Planer V2.00
The new Multiroom Planner doesn't just calculate the correct address assignment for the
M219 Side room amplifiers and
M217 Wall-mounted displays, it also calculates the slot addresses for the M200 series
Re:control products in the side room. Take advantage of the possibility to be able to determine in advance, all M200,
M217 and M219 addresses simply and quickly and at the same time save the information as system documentation. You will find more information about addressing the M200 in the side room, on Page 10 of this manual.
You can download the new Multiroom Planner V2.00 free-ofcharge from the download area of the Revox Homepage, under www.revox.com.
M200 Mk2
New features from software V2.00
From software version 2.00, the
M200 can be connected not only to an M51 but also to the M219
Side room amplifier.
As a result, a Pioneer television can also be controlled from an side room, using the M219 Side room amplifier. The option of connecting an M200 interface to an M219 exists with the first four
Side room amplifiers for each zone. As a result, a total of 16
Side room amplifiers can be connected with an M200 interface in a Revox Multiroom system with 4 different zones.
In the same way as with the setup of an M51, you define which video input at the Pioneer plasma TV is activated by which
M219 audio source, through the
M203 Setup module. The local inputs Local 1 – 3 at the M219 can be used for the control, as well as the audio sources of the
Multiroom Central unit.
Important advice:
If you want to use the software version 2.00, the complete Revox system must be updated to the level 2.00, or higher.
Introduction M200 Mk2
Switching between stations using the Revox wall-mounted keypad
The M200 Mk2 offers the option of selecting specific stations
Note
:
Monitor-only devices
This comfort function is only using the skip keys (
<>
) on an
M218 wall-mounted keypad, once the TV tuner has been selected.
This comfort function requires two settings: available with TV models with an integrated TV tuner. It cannot be selected in case of monitor-only devices without a TV tuner.
2
/2 TV Tuner assignment
M200 Setup #5 - Input
1
/2 Audio IN assignment
M51 in combination with M200
The sound input, e.g. TV, Aux1,
Optical, etc., of the remote device must be assigned to one of the following Remote buttons in the
Remote
menu:
•
Local
•
Local 1
•
Local 2
•
Local 3
Assignment example
M219 in combination with
M200
There is no need to make an assignment through the
Remote
menu with an M219, because its local audio inputs (Local 1-3) are always assigned to the IR commands
Local, Local 1, Local 2
and
Local 3.
Continue with point
2/
2
The second assignment affects
Setup #5
in the M200. Here, the physical audio source of the TV sound that was assigned to a
Local Remote button
in the first step, is assigned to the television's
TV Tuner
.
In the example above, the audio source
TV
calls the television tuner. As well as the Multiroom central unit sources, a side room amplifier also offers its own local
Inputs 1-3 for the
TV Tuner
assignment.
Introduction M200 Mk2
Function Overview
As well as main room operation, the new side room functionality available from software version
2.00 also allows an M200 Mk2 to be connected to an M219 Side room amplifier. You should be aware however, that not all functions are available in the side room. This is highlighted in the individual as well as in the following overview table.
Function
Relay A/B
Trigger Input A/B
Voltage Ramp 0-10 V
IR-Link Input
RS232 Control
1
only in combination with an M-
Link booster – see drawings on pages 14-16.
Re:system M51
Yes
1
;
Yes
;
Yes
;
Yes
;
Yes
;
2
Re:connect M219
Yes
No
No
Yes
Yes
2
1+2
;
;
;
Relay control through the IR remote control (Relay function:
Remote
), is only possible if the
IR Receiver, e.g. M204, M208 is directly connected to the
M200 - see drawings on pages
14-16.
Installation & Connection
Installation
The two wood screws supplied can be used for installing the
M200 Domotic Interface. As well as the four external installation holes, two lateral slotted holes are available for a flexible installation.
M200 Mk2
Connection
You will find a detailed description of the various M200 interface connection options on the following pages.
Slotted hole
∅
4 x 20 mm /
∅
15 mm
Installation hole
∅
4,2 mm
Re:system (M51, M10) resp. Re:connect
Further Re:connect products: M201, M202, etc.
RS232 seriell interface
M-Link connection activity display
Serial interface activity display
Setup button
IR input (M204, M218)
Variable voltage output (OUT 0-10V =)
Trigger input A + B (IN 5-24V =)
Relay A + B (max. 42 Volt)
1
Installation & Connection
Connection:
M200
with
M51/ M219
Socket:
M51 LINK IN
Setup:
-
M219:
Yes
;
The M200 interface is connected with the
M51 LINK
socket on the back of the M51 or the
M219
LINK
socket on the Side room amplifier, using the supplied telephone cable.
If you want to use a different cable, you should only use a
non-crossed
, 4-core telephone cable with an RJ11 plug (6P4C modular).
Max. cable length: 100 m
Max. cable resistance: 0.1 Ω /m
M200 Mk2
Connection
:
M200
with external interfaces
Socket:
M51 LINK OUT
Setup:
-
M219:
Yes
;
The M200 interface is designed for the connection of further external interfaces:
M51 operation
Currently, the following further products can be connected with the M51::
M200
M201
(2. interface)
IR interface
M202
Ethernet interface
M203
RS232 interface
M217
Display
M219 operation
With the M219, the
LINK OUT
can be used for the connection of an M217 Display.
Use a
non-crossed
, 4-core telephone cable with an RJ11 plug (6P4C modular).
Max. cable length: 100 m
Max. cable resistance: 0.1 Ω /m
2
Installation & Connection
Connection
M200
with seriell interface
Socket:
:
RS232
Setup:
# 4 – from page 11
M219:
Yes
;
The
M200
Interface can be used with other (TV) devices, which also have a serial interface.
This enables the integration of a large number of Pioneer televisions into the Revox World.
Which models are supported and how the integration is achieved, is described starting from page 11.
The M200 Interface is also suitable as an interface to domestic facility management systems such as
AMX
or
Crestron
, which have a special Revox protocol.
Even a Windows PC with the
M230
control program can be connected to the serial interface on the M200
Serial cables with a maximum length of 10 metres can be used.
M200 Mk2
Connection
:
M200
Trigger input
Socket:
INPUT A B RS232
Setup:
# 4 – from page 6
M219:
No
Using
INPUT A
and
INPUT B
, you can trigger specific events at the M51. This is done by applying a voltage between 5 and 24 volts (DC) to the corresponding input. There are various options that can be carried out when the input is supplied with voltage.
This function is not available in the side room through the M219 .
Control example
The switching diagram below, shows you how can activate the
Inputs A and B with two keys S1 and S2.
The voltage source is provided by
⊕ and
Θ
on the
IR-LINK
.
3
Installation & Connection
Connection:
M200
Relay output
Socket:
Relay A B
Setup:
# 2 – from page 8
M219:
Yes,
with Link Booster ;
The two changeover relays can be operated in different modes, independently of each other.
Note
:
In active operation, the relays need 18-24 VDC. However when connected to an M219 Side room amplifier or when the M51 is in standby mode, only 12 VDC is available. This means that in these cases, the relays
do not
react to a command.
Solution:
Through the deployment of the
M-Link Booster
, the power is held at a permanent 18 VDC and the relays work reliably in every operational state – see connection diagrams on pages
14-16.
Please note
The switching voltage may not exceed 42 volts.
Switching voltage:
0- 42 Volt*
Max. switching current:
4-8 A*
* dependent on load - See
Technical data
M200 Mk2
Connection:
M200
Voltage ramp
Socket:
Output
Setup:
without configuration
M219:
No
Using the
OUTPUT
, you can control the output voltage with the remote control M208, giving a variable voltage between 0 and 10 volts. This voltage ramp could be used, for example, to set the dimmer control of a lighting system to a desired level
Standard electronic dimmers with a controller input offer the option of adjusting the brightness between 0 and 100%.
Functions:
- On
(with memory function)
-
Off
- Increase voltage
- Decrease voltage
- 10 fixed voltage levels
L
The remote unit control file for the voltage output at the M200 is located in the
M208 Project
Manager
device library, under the heading
Revox – Revox
Domotic M200
. All deployed
RC5 codes are stored in this file .
4
Installation & Connection
Connection:
M200
with IR controller
Socket:
IR-Link
Setup:
# 3 – from page 9
M219:
Yes
;
The connection to an IR receiver or a wall-mounted remote control is done through the 3-pin, screw-fixable Phoenix plug connection.
Revox recommends the use of a
2-core screened cable (microphone cable), where the screening is used as ground. This cable may be a maximum of 30 metres in length.
Please ensure that you use the correct polarity when setting up as otherwise you might damage your equipment.
Symbols:
+
Æ Pos. voltage. 12-20V (DC)
IN
Æ
IR Signal
Æ Ground
-
Important
Relay control through the IR remote control (Relay function:
Remote
), is only possible if the IR
Receiver, e.g. M204, M208 is directly connected to the M200 through the
IR Link
- see drawings on pages 14-16.
The maximum number of IR receivers that can be switched in parallel per
M200
is
3
.
5
M200 Mk2
Configuration
Setup Button
Using the Setup key, you call up the M200 menu, which is shown in the
M51
display.
If the M200 interface is connected with an
M219
Side room amplifier, the M51 display is also used.
In the case of an
M10
installation, display is done using the M230 service program or M-Scope.
Using the Softkeys you can get to pages
#1
till
#5
.
Setup page #5 only appears if a video device has been selected on page #4 as
Serial Port Mode
.
M200 Mk2
Setup #1 –
Control Input
Function
:
Display
:
Trigger input
Control Input A/B
Connection
:
M219
:
Input A/B page 4
No
6
Using
INPUT A
and
INPUT B
, you can trigger specific events at the M51.
The required option can be selected from an option loop by pressing the
Input
und
Input
softkeys.
DVD/CD
Tuner
Tape
Aux 1-3
Local
TV
Video 1-6
Power On
Power Off
System Off
Mute (Toggle)*
Light Dimmer
Not Used
Configuration
DVD/CD - TV
M51 is switched on with and/or switches over to the corresponding source.
Power On:
Switches the M51 on with the last activated source.
Power Off
Switches the M51 off.
System Off
Switches the complete system off, including any side rooms.
Mute (Toggle)
This toggles the mute function of the M51 and is only possible in conjunction with the
5.1 Decoder
Module MK 2 or 3
.
Light Dimmer
Activates the voltage output dimmer function (
Output 0-10V
) with Toggle-Automatic.
Not Used
Deactivates the corresponding input.
Ö
M200 Mk2
Please note
When you are selecting the source, you should be aware that the source that has been assigned to the corresponding button in the
Remote
menu will be selected. If a source is disabled through the
Remote
menu, it will not be activated, even when it is selected in the input option.
Further information on this topic can be found in the M51 Operating Manual in the
Introduction
chapter, in the description of the
remote
function.
7
Configuration
Setup #2 – Relay
Function
:
Display
:
Relay output
Func. Relays A/B
Connection
:
M219
:
Relay page 4
Yes,
with Link
Booster
;
The two relays each offer 5 options that can be selected with the keys.
Input
and
Input
soft-
The required option can be selected from an option loop:
Remote
Open
Close
Power On/Off
TV-Lift
Please note
The switching voltage may not exceed 42 volts.
Switching voltage:
0- 42 Volt*
Max. switching current:
4-8 A*
* dependent on load -
See Technical data
M200 Mk2
Relay Functions
Remote
The relays are controlled over IR commands (M208) with
Remote
. This function is only available if a Link Booster is installed upstream of the M200.
L
M219 - Cabling
The IR Receiver must be connected directly with the M200.
See Connection plan on page
14.
Open
The relay is in idle state
Close
The relay is energised.
Power On/Off
If the M51/ M219 is switched on, the relay is energised. In standby mode, the relay is in idle state.
TV-Lift
The relay is energised dependent on a selected M51 audio source. The decision is made by the assignment of a video source to an audio source on page
#5
of the M200 Setup
This function can be used to roll out a projector screen or to activate a TV lift.
At the same time, the correct video device input can be controlled through the serial interface.
8
Configuration
Setup #3 – IR-Address
Function
Display
:
:
Connection
:
IR Address
Remote Address
-
M219:
Yes
;
The relay and dimmer functions can be controlled through the remote control and/or a connected M218 wall-mounted operating panel.
Through the selection of the
(RC5-) remote address, you can define whether the relay and dimmer functions should be operated from the remote control and the wall-mounted operator panel or whether only one of them should be accepted.
Address Transmitter
Light (30)
Local (19)
Remote control
Wall mounted remote control
Both (30+19)
Combination
L
The remote address has no relationship to the slot address, which the M200 uses to register with the M51/ M219.
9
M200 Mk2
Setup #3 – Source
Function
:
Display
:
Connection
:
IR receiver
Remote Source
inc. IR-Link - page 5
M219:
No
Selection of the (IR) sources that the M200 interface accepts for dimming and relay functions as data suppliers.
This M-200 only
Accepts only sources that are directly connected to the M200’s
IR Link, e.g..
MR204
or
M218
wall-mounted remote control.
All Receivers
All sources are accepted as data suppliers, e.g. also a M51 or an additional M200 interface.
This setting has no effect in the case of a side room installation with an M219.
Configuration
Setup #4 a) Slot M51
Function
:
Display
:
Addr. assignment
Slot Address
Connection
:
M219:
M51-Link – page 2
Yes
;
M51 operation – fig. page 15
If a second M200 (M203) is connected to the
M51 Link
output, a different address must be assigned through the slot selection so that both M200s don’t occupy the same slot address. This would cause errors. In the case of a double assignment, neither of the two
M200s would be shown in the M51
Version list.
Slot Address :
#11
or
#12
The two slot addresses 11 and 12 are available for selection. The following message appears (Display
:
#xx occupied)
if the selected address is already assigned:
M200 Mk2
Setup #4 b) Slot M219
M219 operation - fig. page 13
In respect of the M219, the slot address defines the assignment to the Side room amplifier. A M200 can only be connected to an Side room amplifier within the address range
x1 – x4.
10
The slot address defines which
Side room amplifier the M200 interface should communicate with. This is necessary because of the bus system, although in each case, the M200 is individually connected with the M219. Only one
M200 interface can be used per
Side room amplifier.
Address assignment : Zone 1-4
M219/ 217 M200/ M203
x 1 x 2 x 3 x 4 x 5 x 6
Ö
Ö
Ö
Ö
x
x
x
x x 7 x 8
x 1 – x 4: only M219
x 5 – x 8: M217 or M219
x 11 – x 14: only M200 / M203
Configuration
Example
In Figure A, an M200 could be connected to each of the Side room amplifiers 31 – 34. The M219 amplifiers 35 and 38 on the other hand may not be connected with an M200 interface.
Fig A. Multiroom version list / Zone 3
The figure below shows the Multiroom version list from Zone 3 for the M200 interfaces. You get to this menu by repeatedly pressing the
Zone
softkey in the sub-menu
(M51, M230 etc.) of: Setup Ö
Multiroom Ö Version
Ö Zone x
In this case, an M200 interface was assigned to the Side room amplifier with address 4, through the slot address 314. Amplifiers 1
– 3 do not have an M200.
Fig B. Multiroom version list / Zone 3
M200 Mk2
Setup #4 – RS232 Modus
Function
:
Display
:
RS232 interface
Serial Port Mode
Connection
:
M219:
RS232 – page 3
Yes
;
The function of the serial interface (
Serial Port
) can be configured for the following applications:
•
RS-232 Link
•
RS-232 Filtered
•
Gefen HDMI Switcher
4x2, 4x1
•
Gefen HDMI Switcher
6x2
•
Pioneer
PDP 5000 EX
•
Pioneer
PDP 506 FDE
•
Pioneer
PDP 506 XDE - Cable
•
Pioneer
PDP 506 XDE - DVBT
•
Pioneer
PDP 507 XA
•
Pioneer
PDP 507 XD
•
Pioneer
PDP 508 XD
•
Pioneer
PDP 607 XD
•
Pioneer
PDP 60 MXE20
•
Pioneer
PDP 615 EX
•
Pioneer
PDP LX5090H
•
Pioneer
PDP LX5090
•
Pioneer
LCD KRL-32V
•
Pioneer
LCD KRL-37V
•
Pioneer
LCD KRL-46V
•
Pioneer
KRP 500A*
•
Pioneer
KRP 600A*
* with setting PDP LX5090 H
Please take note of the important information on page 13 relating to a
complete reset
of the M200.
11
Configuration
Setup #4 – Auto Standby
Function
:
Display
:
Auto Standby
Auto Standby
Connection
:
M219:
RS232 – page 3
Yes
;
The
Auto Standby
function enables the TV to remain switched on, even in the case of selected audio sources that do not activate a video input at the
TV, e.g. the M51 radio tuner.
M200 Mk2
RS-232 Link .
Standardised serial interface
(RS232 protocol) for connection to a PC or another serial interface.
The
Auto Standby
option is only shown in the menu if a
Pioneer
model has been selected as
Serial
Port Mode
.
Auto Standby: ON
The Plasma TV switches itself
off
automatically as soon as an audio source is selected, which either cannot activate a video input, e.g.
Tuner, or which is
disabled
Auto Standby: OFF
After the Plasma TV has been switched on, it remains on
permanently
until the M51/ M219 is switched off, irrespective of which audio source is selected.
Application:
You should select this setting if you want to use the
M230
control program for PCs or if you want to access the Revox System through domestic facility management equipment such as
Crestron and AMX.
RS-232 Filtered .
Data-reduced RS232 protocol.
Only M51-specific data is transferred, so-called display and broadcast messages.
Application:
Simple controllers with low data traffic requirements.
12
Configuration
Video Controller
If a video controller for a plasma
TV was selected on page #4
Port Mode
, a second menu page,
Setup # 5
is available.
This page enables you to selectively switch on and/or between video inputs on a Pioneer TV or an HDMI Switcher from the Gefen company, dependant on the selected M51/ M219 source.
Example M200 with M51:
A SAT receiver can conveniently be integrated through the automatic selection of the video input on the TV by the M51. Its picture output is connected, for example, to the
Input-2
on the Pioneer TV, while the audio signal is connected to the
Optical
digital input on the M51.
Please also refer to the picture on the next page.
If you now select the source
SAT
(
Optical
) at the M51, the Pioneer
TV automatically transmits the
SAT receiver picture over the
Input-2
and the sound from the
SAT receiver is transmitted over the M51.
13
M200 Mk2
The convenient integration can of course also be used for the
M51’s integrated DVD player.
Please refer to the picture on the next page – Connection : Video
1).
The audio source and video input links referred to in the example are defined in Setup #5.
You will find an exact description of the links, starting from page 21.
Complete reset?
Yes
You should always carry out a complete reset with each new configuration as well as when changing to another TV model.
To do this, press the
Disable
softkey on Setup page #2 and keep it pressed, until the system automatically returns you to page 1.
No
A complete reset is
not
necessary with an assignment change within a TV model.
Configuration
Connection plan: Pioneer TV with M51
M200 Mk2
_
Adapter *
Connection plan: Pioneer TV with M219
_
Adapter *
* Adapter is model-dependent, see page 18
14
Configuration
Connection plan: HDMI switch with M51
M200 Mk2
Note
The HDMI output on the M51 is only available if the DVS module is installed.
Gefen
®
: Registered trademark of the Gefen Company/ US
15
Configuration
Connection plan: Pioneer TV with M219
M200 Mk2
16
Configuration
Gefen HDMI Switcher 4x2, 4x1
Switcher 6x2
Control software for the HDMI
Switcher from the Gefen Company (www.gefen.com)
The HDMI inputs on the HDMI switcher are activated, dependant on the M51/ M219 source. If there is no assignment, the HDMI input that was last selected remains active. Setting is done on page #5 in the M200 Setup
Product features:
- 4 HDMI inputs (4x1,4x2)
- 6 HDMI inputs (6x2)
- 1 HDMI outputs (4x1)
- 2 HDMI outputs (4x2),
whereby both outputs can be
operated in parallel
- Resolution up to 1080p
- HDCP-enabled
- Optical audio digital output
A crossed Sub-D cable (plug – plug) is required for the transmission.
Type:
Plug-Plug
For this reason, you should use the enclosed crossover adapter and gender adapter with the supplied Revox cable.
+
17
9-Pol
Pin 2
Pin 3
Pin 5
M200 Mk2
⇒
9-Pol
⇒
⇒
⇒
Pin
Pin
5
Max. cable length RS232: 10 m
Gefen products are freely available through specialist retail outlets.
Configuration
Pioneer Models:
PDP 5000 EX
PDP 506 FDE
PDP 506 XDE-C
PDP 506 XDE-DVBT
PDP 507 XA/ XD
PDP 508 XD
PDP 607 XD
PDP LX5090 H
PDP LX5090
KRP 500A*
KRP 600A*
The models listed above require a crossover serial cable, also known as a null modem cable, as the control cable between the
M200 and the Pioneer TV.
Connection type:
Plug - Socket
For this reason, you should use the enclosed crossover adapter with the supplied Revox 1:1 cable
9-Pol
Pin 5
Pin 2
Pin 3
⇒
9-Pol
⇒
⇒
⇒
Pin
Pin
2
M200 Mk2
Pioneer Models:
PDP 615 EX
PDP 60 MXE20
LCD KRL-32V
LCD KRL-37V
LCD KRL-46V
The models listed above require a normal serial 1:1 cable, as the control cable between the M200 and the television.
Connection type:
Plug - Socket
The supplied Revox 1:1 cable conforms to this configuration and can be used directly, without an adapter.
9-Pol
Pin 5
Pin 2
Pin 3
⇒
9-Pol
⇒
⇒
⇒
Pin
Pin
3
Max. cable length RS232: 10 m
* with setting PDP LX5090 H
Max. cable length RS232: 10 m
18
Configuration M200 Mk2
Activating the Pioneer RS232 interface - PLASMA
Models: PDP 506 / PDP 507
The RS232 interface must be activated in the
Integrator
menu, so that these Pioneer models can receive the commands from M200 Pioneer.
Please take note of the sequence of activation on the RS232 mode.
Under certain circumstances, the
Integrator
menu doesn’t appear the first time. If this happens, please repeat the process.
1)
Switch on / switch over the plasma television to TV mode
2)
3)
4)
5)
6)
Place the plasma television in standby mode
Press and release the
i
+
(
INFO
)
button on the Pioneer remote control .
[Point 3 is not always necessary. It depends on the manufacturing date of the Pioneer Plasma]
Press and release the
HOME MENU
button on the Pioneer remote control .
Follow this without delay, by pressing and releasing the
(Power) button
Deactivate the
SR+
mode in the
Integrator
menu that now appears. This activates the RS232 mode at the same time
7)
8)
Confirm the change by pressing the
HOME MENU
button
Switch the device off and restart
Model: PDP 508
The PDP 508 model does not have an explicit
SR+
mode within the
Integrator menu. In fact, the baud rate of the Pioneer interface can be set through the Integrator menu. The baud rate should be set to
9600
for communication with the M200.
Model: PDP 5000EX
With the PDP 5000 EX, the RS232 interface is activated in the normal user menu (HOME MENU – Setup – SR+).
Models: PDP 615EX / PDP 60MXE / PDP LX 5090 H
PDP LX 5090 / KRP 500A / KRP 600A
With these models, the RS232 interface is already activated. No further activation settings are required.
19
Configuration
Activating the Pioneer RS232 interface – LCD
M200 Mk2
Models: LCD KRL-xxV
Following the initial commissioning of a Pioneer LCD television, its serial interface (RS232) is not yet configured for control by an external device, like the M200 Pioneer in our case. The RS232 interface is only permanently activated once a one-off initialisation command is sent through the M200 interface to the LCD television. Activation is done with the following steps:
1)
2)
3)
Carry out a complete reset (see Page 13)
Make the settings as described in
"Setup #5 – AV Assignment", from Page 21.
Switch on the M51/M219 with FM Tuner. If no FM Tuner is in-
4)
5)
stalled, select a source that is not linked to a television video input in Setup #5.
Switch on the LCD television with the original remote control, using the
Power
button.
Wait until the television is ready to receive.
6)
7)
Now select a source at the M51 (or at the M219 Side room amplifier), which is linked to a television video input in Setup
#5.
The LCD television is now initialised and retains the facility to be controlled through the serial interface, even when it is switched off.
Please note:
If the television is changed, the process described above has to be repeated.
Pioneer LCD special characteristic
The LCD inputs
Input 3
and
Input 8
can only be addressed by the
M200 if there is already a signal at its input. If this is not the case, the
LCD television recognises this and ignores the control command.
20
Configuration
Setup #5 – AV Assignment
Function
:
Display
:
AV Assignment
Source
Connection
:
M219:
RS232 – page 3
Yes
;
Unknown audio sources
"Sources unknown" can still be present during the initial configuration, caused by the swap or the de-installation of modules.
M200 Mk2
1. Selecting audio source
To start with, select the M51 /
M219 audio source that later should activate a particular video input on the Pioneer television/ HDMI Switcher, using the
Source
± softkey.
Following switch-on, it can take a few seconds until the M200 interface has identified all the
M51 / M219 sources and until the
Source ”Unknown"
message disappears.
Any remaining unknown sources should be deleted by pressing the
Disable
softkey twice and then pressing the
Delete
softkey.
If too many unknown sources are present, we recommend completely resetting the M200 interface by pressing the
Disable
softkey for several seconds, until Page #1 automatically appears
.
Using the
Source+
and
Source-
softkeys, you can step forwards and backwards respectively, through a loop of audio inputs, which are currently available on the M51 / M219.
If the name of an audio source has been changed, the modified name also appears in the list.
An
“Unknown” Source
must be deleted manually. You will find more information about this in the previous section.
21
Configuration
Intelligent Audio Sources
The M200 differentiates between 3 type of audio sources:
1. Permanent sources
2. Semi-intelligent sources
3. Intelligent sources
1. Permanent sources
In the case of permanent audio sources, including for example the
Tuner
source, the television is switched on immediately with the corresponding video input that was assigned to it on Setup page #5. Manual switch-on or switch-off through the remote control is not possible.
2. Semi-intelligent sources
In the case of semi-intelligent sources, you can define through the remote control, whether the television should be switched on with the previously defined video input or not. Such sources have respectively
TV ON
and
TV OFF
function keys in the remote control menu. The semi-intelligent sources, such as the M37 Music
Server, store the last selected state.
If, for example, the video input from the
Server
was activated at the television using the remote control, the television is automatically activated next time this source is selected.
M200 Mk2
3. Intelligent sources
In the case of intelligent sources, it is a question of sources, which, dependant on setting or medium, can transmit a video signal to accompany the audio signal. An example of an intelligent source is the DVD/CD
M51 source. If there is a music
CD on the M51 drive, the television is not switched on because in this case, no video is required. If, on the other hand, a
DVD is identified, the television is switched on.
Source – Switch on
Yes/No
DVD/CD:
CD Switch on:
No
DVD Switch on:
Yes
;
SAT:
Radio Switch on:
No
TV Switch on:
Yes
;
22
Configuration
Setup #5 – AV Assignment
2. Assigning video inputs
In the second step, a video input from the television / HDMI
Switcher is assigned to the selected M51/ M219 audio source, using the
Input
±
softkey. Using the
Input
±
softkey, you can step through a loop of video inputs that are available to the television.
M200 Mk2
The following display appears, if a video input is called by one or more audio sources:
As the televisions that can be selected from have different video inputs, only those video inputs that the corresponding TV device has, are actually displayed.
The softkey
Store
appears as confirmation each time the
Input
is changed. Press
Store
if you want to save your changes.
Otherwise the original setting is retained.
Assignment example
This example shows you that, as well as the currently displayed audio source (DVD), a further audio source has also been assigned to this video input
(here
Input 2
). Using the
Source
±
softkeys, you can search for the audio source that also calls this video input.
Several audio sources are always required if, for example, the M300/M301 Video switch is used, which bundles several video sources together to one video input on the television.
23
Configuration
Setup #5 – Function
TV-Lift
Relay activation
When assigning video inputs, you define at the same time which inputs should activate the relays if the
TV-Lift
function has been selected in Setup #2. If the audio source has no assignment and remains "disabled", the relay is not activated.
When changing from a TV-Lift source (relay active) to non-TV-
Lift source, the relays are deactivated after a timeout of 20 seconds. This prevents the screen from being retracted and rolled out again unnecessarily, for example, in the case of an accidental source change.
Please refer to page 8 – Setup #2 for the configuration of the relay function.
M200 Mk2
Example:
Settings definition – Setup #5
Settings definition – Setup #2
Effects
1. Æ Setup #5
The audio source "DVD/CD" switches the Pioneer television on / over to the video input "
Input 2
" as soon as a
DVD is identified in the drive.
With a CD, the Pioneer television is or remains switched off.
Æ "Intelligent sources" See page 20.
2. Æ Setup #2
Relay A is activated.
Relay B can only be activated through the remote control.
24
Configuration
Setup #5 – Disable
Disable assignment
Using the
Disable
function, you can undo or disable the assignment of an audio source to a video input.
M200 Mk2
Reset assignment
If you want to return the settings in Setup #2 menu to the factory settings, simply press and hold the
Disable
softkey until the
Setup- #1
page appears again.
To do this, select the required audio input using the
Source ±
softkeys and then press the
Disable
softkey. The
Store
softkey then appears that you need to press to confirm your change.
This resets all input assignments and restores the factory settings.
If you don’t press
Store
, the original setting is retained.
25
Appendix
Guarantee
The guarantee period is 24 months from the date of purchase.
Your dealer should be your first contact if you need service. If he can't give you the help you need, send your M200 interface carriage free and without any accessories to your national
Sales Office.
Please supply a complete description of the problem and a full return postal address.
M200 Mk2
Included in delivery
M200 Domotic Interface
M51-Link cable ( 2 m )
Serial PC cable
(1:1 - length 3 m)
(Plug-Socket)
RS232 Crossover adapter
Gender adapter
Accessories (Installation)
Manual
26
Appendix
Technical Data
M200 Mk2
Relay: A - B
Switching voltage
Max. switching current with
- Alternating current (AC):
- Direct current (DC):
INPUT: A - B
Max. input voltage.
Threshold voltage input resistance max. 42 Volt
8 Ampere (ohmic or inductive load)
8 Ampere (ohmic load)
4 Ampere (inductive load)
24 Volt (DC)
5 Volt (DC)
2 kOhm
Please ensure correct polarity
OUTPUT:
Output voltage
Max. output current.
0-10 Volt (DC)
10 mA
Please ensure correct polarity
IR-LINK:
+
Æ Positive voltage 10-20V (DC)
IN
Æ
-
Æ
Dimensions
:
Weight
IR signal
Ground (GND)
140 x 65 x 40 mm (W x H x D)
330 g
Power consumption: 36 mA (without IR receiver)
Max. cable length:
Max. cable length:
100m (M200-M51)
30m (M200- IR-receiver)
E & OE
Product subject to technical modifications.
27
Appendix
Wiring the M200 interface
M200 Mk2
28
Appendix
GERMANY
Revox GmbH, Am Krebsgraben 15, D-78048 VS-Villingen
Phone +49 7721 8704 0, Fax +49 7721 8704 29 [email protected], www.revox.de
SCHWEIZ
Revox Schweiz AG,
Wehntalerstrasse 190, CH-8105 Regensdorf
Phone +41 44 871 66 11, Fax +41 44 871 66 19 [email protected], www.revox.ch
Zentralservice
Revox GmbH, Am Krebsgraben 15, D-78048 VS-Villingen
Phone +49 7721 8704 43, Fax +49 7721 8704 49 [email protected]
M200 Mk2
Copyright by Revox GmbH, Germany.
29
advertisement
Key Features
- Control Pioneer TV from your Revox system
- Select video input automatically
- Control TV functions
- Side room functionality
- Connect to M51 or M219
- New Multiroom Planner V2.00