Arlec AM490 is a compact and reliable passive infrared sensor alarm that provides 24/7 security, safety, and convenience. It features two modes: chime and alarm. In chime mode, it produces a "ding-dong" sound when motion is detected. In alarm mode, it emits a continuous siren for approximately 15 seconds, automatically resets, and reactivates upon further movement.
advertisement
Compact Entry Detector
INSTALLATION & OPERATING INSTRUCTIONS
AM490
INTRODUCTION
The Arlec Compact Entry Detector is a compact, passive infrared sensor alarm which provides reliable detection 24 hours a day providing security, safety and convenience. The detector can be used in two different modes, chime or alarm. The chime provides a ding-dong sound when detection is made. In the alarm position a continuous siren sounds for approximately
15 seconds, resets automatically and then sounds again if further movement is detected.
INSTALLATION
1. Remove battery cover and place 9 volt battery in compartment (suitable for use with Arlec
Rechargeable battery(BSP9V). The unit can also operate from a mains adaptor if 240 volt mains power is desired.
2. Select location and mount bracket with double sided foam tape or use screws provided.
(Bracket can be unclipped from the sensor for screw mounting.)
3. Adjust sensor position to cover desired detection area.
4. Switch on detector to either chime or alarm. The unit is now set, and has an in built time delay of approximately 20 seconds to allow you to move away. When set on the unit will chime immediately to signify the start of the 20 second delay period.
AM490_CPIN44/2.indd 1 14/05/10 9:17 AM
USER HINTS
1. For doorway entry, mount the detector vertically to cover a narrow detection area and set to chimes (Fig. 01).
2. For alarm operation, mount the detector horizontally to cover a wide detection area (Fig. 02).
3. Not recommended to operate through glass (for applications where detection through glass is required we recommend
Arlec Security Beam AM471.)
4. Do not install your Entry Detector where it can be exposed to direct sunlight.
5. Do not install on or near heat sources such as radiators, bright lights or near cook tops or stove. The indirect heat may cause the alarm to activate.
6. Avoid installing your Entry Detector where severe changes in ambient temperatures may occur.
7. On very hot days the sensitivity may be decreased due to the ambient temperature being closer to normal body temperature, this is unavoidable. On very cold days the sensitivity may also be affected when people are wearing extra clothes and therefore emitting less body heat for the sensor to detect.
GUARANTEE
VERTICALLY WALL MOUNTED
VERTICALLY WALL MOUNTED
SIDE VIEW TOP OR PLAN VIEW
Fig.01
HORIZONTALLY WALL MOUNTED
130
SIDE VIEW
SIDE VIEW
130
TOP OR PLAN VIEW
TOP OR PLAN VIEW
Fig.02
Arlec guarantees this product against defects of materials and workmanship for a period of 12 months from the date of purchase provided that the product is used in accordance with Arlec’s recommendations and within such voltage and current limits as are specified by Arlec in relation to the product. Arlec will at its own option make good, replace with the same or similar product, or provide credit for any product manufactured or supplied by it, which proves to be defective within the limits set out above provided that no repairs, alterations or modifications to the product have been undertaken or attempted, other than by the company or its authorised agents. Should the purchaser wish to make a claim under the guarantee, the product should be returned pre-paid to the place of purchase. This guarantee is in addition to and does not take away from any rights available to the consumer under the Trade Practices Act and the State consumer protection legislation.
Proof of Purchase
• Please retain your purchase receipt for all warranty claims.
For all Sales enquiries Phone (03) 9727 8860 Fax 1300 360 650
© This instruction leaflet is subject to copyright and must not be reproduced, copied or otherwise used in any way or for any purpose without the consent in writing of the owner, Arlec Australia Pty Ltd (ACN 009 322 105).
AM490_CPIN44/2.indd 2
CPIN44/2
14/05/10 9:17 AM
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement