EchoTouch Two-Wire Ultrasonic Level Transmitter APPLICATION Level Transmitter

EchoTouch Two-Wire Ultrasonic Level Transmitter APPLICATION Level Transmitter
Level
Transmitter
TM
EchoTouch Two-Wire Ultrasonic Level Transmitter
APPLICATION
SPECIFICATIONS
CSA approved intrinsically safe for use in
general purpose or hazardous applications, the two-wire ultrasonic transmitter
provides non-contact level measurement up
to 18’ or 5.4m, and is ideally suited for challenging corrosive, slurry or waste liquids. Push
button calibrated, the transmitter is typically
selected for atmospheric bulk storage, day tank
and waste sump applications located within a
classified area. Media examples include diesel
fuel and sulfuric acid.
Range:
FEATURES
Intrinsically safe transmitter for
use in hazardous environments
LU20
Shown
LCD digital display indicates
level in inches or centimeters
EasyCal simple push button
calibration for all user set points
IP
65
PP enclosure rated NEMA 4X
with rugged PVDF transducer
Adjustable dead band and range
filters eliminate false echo returns
Faceplate
Shown
6" to 18'
(15 cm to 5.4m)
Accuracy:
± 0.25% of span in air
Resolution:
0.125" (3 mm)
Beam width:
8˚ conical
Dead band:
6" (15 cm)
Display type:
LCD, 4-digit
Display units:
Inch or cm
Memory:
Non-volatile
Supply voltage: 12-32 VDC
Loop resist.:
600 Ohms @ 24 VDC
Signal output:
4-20 mA, two-wire
Signal invert:
4-20 or 20-4 mA
Calibration:
Push button
Fail-safety:
Reverts to safe state
during echo-loss
Process temp.:
F: -4˚ to 140˚
C: -20˚ to 60˚
Temp. comp.:
Automatic
Electronics temp.: F: -40˚ to 140˚
C: -40˚ to 60˚
Pressure:
30 psi (2 bar) @ 25˚
C., derated @ 1.667
psi (.113 bar) per ˚C.
above 25˚ C.
Enclosure rating: NEMA 4X (IP65)
Encl. material:
PP, UL94VO
Trans. material: PVDF
Process mount: 2" NPT (2" G)
Mount. gasket:
Viton®
Conduit entrance: Single, 1/2" NPT
Classification:
Intrinsically safe
Approvals:
CSA: Class I, Groups A,
B, C & D; Class II, Groups
E, F and G; Class III; T3C
EEx: Class 1, Division 1,
Groups A, B, C, D; EEx
ia IIC T3
Parameters:
CSA: Vmax < 32.0 V;
Imax < 130 mA; Ca =
0 μF; La = 0 μH
EEx: Ui = 32 V; Ii =
300 mA; Pi = 1.3 W;
Ci = 0 μF; Li = 0 μH
CSA: LR 79326
Certificates:
CE compliance: EN 61326 EMC
LB10
Shown
Echotouch
LM50
Shown
ORDER
LU20-50
Process mount (1) (2)
0
2" NPT (US)
6
2" G (Metric)
1-IS
Ordering Notes
1) For installation on open tanks, order the
LM50-1001 (2" NPT) or LM50-1061 (2" G)
side mount bracket.
2) When used in hazardous environments, order
the LB10-1001 intrinsic safety barrier.