Friedrich Brochure

Friedrich Brochure
Packaged Terminal
Air Conditioners
SG Series
Efficient and reliable for
the lowest cost of ownership.
More efficient. More reliable.
Greater guest comfort.
TH E E X P E R TS I N RO O M A I R CO NDI TI ON I N G
“We did quite a lot of research before
we picked Friedrich. We visited several
installations and talked with the
maintenance people. We asked about
reliability, noise, accessibility of spare parts
in rural locations, ease of maintenance and
Friedrich came out on top.”
The Friedrich PTAC SG Series offers the durability
and efficiencies you’ve come to expect from Friedrich,
and more. Improved performance and design
enhancements combine to deliver our most efficient
and reliable PTAC yet.
All backed by an industry-leading 2-year parts and
labor warranty, and 5-year limited warranty.
2
2 YR.
WARRANTY
PARTS AND LABOR
5 YR.
LIMITED WARRANTY
More
Efficient
More
Reliable
Greater
Guest Comfort
New design for higher energy efficiency
Electric Heat
The advanced coil design of the SG Series maximizes the internal surface area
to deliver higher efficiencies providing EERs of up to 13.0.
COOLING
7000-14500 Btu
Up to 13.0 EER
ELECTRIC HEAT
8300-17000 Btu
Dependable performance you can count on
It begins with the highest quality materials and components such as stainless steel
endplates on the coils and galvanized, zinc-coated steel wall sleeves brought together
with durable construction and rigorous testing. Friedrich PTACs are built to deliver
years of reliable performance.
Guests can select the Constant Fan mode, which produces a
steady stream of white noise in both cooling and heating
modes that masks sound level changes when the compressor
cycles on and off, and also masks outdoor noise.
A complete line of PTACs–
COOLING
7000-14500 Btu
Up to 13.0 EER
HEATING
5800-13300 Btu
Up to 3.6 COP
Engineered for maximum guest comfort
Quiet, yet powerful airflow quickly reaches all corners of the
room. The two motor design and thick insulation on the inner
walls reduce the indoor sound levels.
Heat Pump
The tangential blower wheel
creates a wide path air flow
that reaches the furthest
corner of the guest room.
5X TH
E SUR
FA C E
WIDER
AREA
AIR P
=
AT H
• Available in electric heat and heat pump models
• 7,000 to 15,000 Btus
• All capacities have multiple heater options
• 230 and 265 volt.
3
Modular design for easy access to
key components
DiamonBlue
Advanced Corrosion
Protection™ comes
standard on all
PTACs for long life
in harsh coastal
environments.
Reversible
louvers for
air path
modifications
Easy-access,
interchangeable
antimicrobial air
filters
Indoor coil frost sensor
protects compressor
Durable, powder
coat paint finish
Outdoor coil
has Diamonblue
Advanced Corrosion
Protection® and
stainless steel
endplates
Quiet, efficient rotary
compressor mounted on
large vibration isolators
Friedrich reliability backed by an industry-leading 2-year
parts and labor and 5-year limited warranty.
2 YR.
WARRANTY
PARTS AND LABOR
5 YR.
RECEPTACLES AND FUSE TYPES
LIMITED WARRANTY
See warranty documentation for full details.
Voltage
Amps
230V
15
20
265V
30
15
20
30
2.5 kW
3.5 kW 5.0 kW
2.5 kW 3.5 kW 5.0 kW
NEMA#
Receptacle
6-15R
6-20R
6-30R
7-15R
7-20R
7-30R
NEMA#
Plug
6-15P
6-20P
6-30P
7-15P
7-20P
7-30P
Heater Size
Receptacles
4
Features
DURABLE & RELIABLE CONSTRUCTION
COMFORT, HEALTH & IAQ
Stainless steel endplates reduce outdoor coil corrosion.
Dehumidification removes up to 3.1 pints/hour of moisture in
cool mode to improve comfort and reduce the chance of mold
and mildew growth.
Galvanized zinc coated steel wall sleeve and steel base pan
undergo an 11-step preparation process, are powder coated with
a polyester finish and cured in an oven for exceptional durability.
Additional heating element bottom plate above an improved
heat shield provides extra thermal protection.
Additional thermistor on the blower scroll outlet regulates
internal temperature
Factory run-tested units reduce problems in the field.
Internal diagnostic program can alert maintenance to component
failures or operating problems. Fourteen numeric service error
codes stored in memory facilitate rapid unit diagnostics.
Easy access anti-microbial filters simplify maintenance and
extend the life of the product.
Room freeze protection initiates heat if temperature falls to 40°F
in an unoccupied room.
Random compressor restart protects electrical systems from
overload when power is restored.
Tamper-resistant, anodized stamped aluminum grille
withstands chalking and oxidation.
Break-proof control door design maintains the integrity of the unit.
Indoor coil frost sensor protects the compressor to lengthen the
life of the unit.
Diamonblue Technology protects the outdoor coil from harsh
environments.
Industry leading warranty features 2 year full warranty on parts
and labor and 5 year limited warranty.
Nationwide service network and U.S.-based Friedrich expert
technical team ensures you get fast, knowledgeable service.
ENERGY EFFICIENT & ENERGY SMART
Super-efficient refrigeration design with EERs up to 13.0 and
COP up to 3.6.
Exceptional FriedrichLink® energy management thermostats
available (wired & wireless) with integrated occupancy
sensor, five distinct energy presets and comprehensive remote
management capability.*
Advanced coil design adds more surface area leading to
higher efficiencies.
Thicker steel inner-wall and foam construction decreases
thermal transfer and energy loss.
Constant Fan mode provides constant fan operation in cooling
or heating modes to create a steady stream of white noise that
masks sound level changes when the compressor cycles on/off.
Fresh air damper brings in fresh outside air when desired.
Intuitive unit controls are user friendly with easy-to-read
LED display that can show either set-point or actual room
temperature as selected by owner.
Anti-microbial air filters are easy to access and washable.
Instant Heat on heat pump models quickly heats a room to the
desired temperature for increased comfort.
Even-heat monitoring checks room temperature and
automatically adds heat boost if necessary.
Automatic periodic sampling of room temperature to ensure
desired conditions are maintained.
Reversible indoor air louvers to easily change direction
of airflow.
EASE OF MAINTENANCE &
INSTALLATION
Ease of SKU creation as universal heaters with heat capacities
are determined by the power cords; can achieve up to 40 PTAC
SKUs with 16 units by changing the power cord size.
Modular product design ensures easy access to key components
for cleaning and repairs, including
washable, lift-out air filters.
Remote thermostat pop-out wiring module
allows easier wiring and unit change out
without rewiring thermostat.
Compact front is designed to preserve
indoor floor space with a depth of 7¾
inches.
Faultless Sure-hold Front Cover System
securely attaches the front each time.
Inner wall service plate provides service
access to tangential blower bearing without
having to open up the entire inner wall.
May be installed flush with the floor.
Energy efficient heat pump models available in our complete line.
SOUND REDUCTION TECHNOLOGY
Electronic defrost control ensures more run time in efficient
heat pump mode.
Two permanently lubricated fan motors for added durability
and reduced sound levels indoors.
Electronic temperature limiting to adjust low/high temperature
range limits for reduced energy usage.
Quiet, efficient rotary compressor mounted with vibration
isolators to keep the compressor running smoothly and quietly.
Slinger ring technology in condensate removal system cools the
coil and increases efficiency.
High-density insulation and steel inner wall block outdoor noise.
Desk control ready to allow hotel owners to control units from a
central location.
* Energy management capability requires purchase of additional hardware and service fee.
5
OPTIONAL ACCESSORIES
WALL SLEEVE
PDXWSA
Galvanized steel is prepared in a state-of-the-art, multi-step process for
stronger paint adhesion, then powder coated with a polyester finish and
cured in an oven for exceptional durability. The wall sleeve is insulated for
thermal efficiency and noise reduction.
SLEEVE DIMENSIONS: 16" H x 42" W x 13 ¾" D
CUT OUT DIMENSIONS: 16 1/4" H x 42 1/4" W
FRONT COVER DIMENSIONS: 16" H x 42" W x 7 3/4" D
DEEP WALL SLEEVES
PDXWSEXT18
For walls up to 17 1/2” deep.
PDXWSEXT24
For walls up to 23 1/2” deep.
Deep wall sleeve extension PDXWSEXT18 shown with
weather panel in place
PDXWSEXT (Custom depth wall sleeve)
One-piece extended wall sleeve for walls from 13 1/4" to 25 1/2" deep are
available by special order.
SLEEVE EXTENSION RETROFIT KIT
PXSE
2 ¼" sleeve extension attached to the room side of the sleeve to allow for the
installation of a PD-series Friedrich PTAC in a 11 ½" deep T-series sleeve.
DIGITAL REMOTE THERMOSTAT
RT6
Single stage cool, single stage heat for PDE models or single stage cool, dual
stage heat for PDH model thermostat features high/low fan speed switch.
Thermostat is hard wired and can be battery powered or unit powered.
Features backlit display and multiple configuration modes.
WRT1
RT6
WRT1
Wireless, single stage, wall-mounted digital thermostat with two fan
speeds. Features backlit display and multiple configuration modes.
FRIEDRICHLINK® ENERGY MANAGEMENT THERMOSTATS
EMRT1
Wired thermostat with occupancy sensor.
EMWRT1
Wireless thermostat with occupancy sensor.
EMOCTEMRAF
Online connection kit.
Remote access fee.
REMOTE THERMOSTAT ESCUTCHEON KIT
PDXRTA
Kit contains escutcheons that can be placed over the factory control buttons
when a remote wall mounted thermostat is used. The escutcheon directs
the user to the wall thermostat for operation and retains the LED window to
display error codes and diagnostic information. 10 pack.
CONDUIT KIT /JUNCTION BOX
PXCJA
Hard wire conduit kit with junction box for 208/230V and 265V units (subbase
not required). Kit includes a means of quick disconnect for easy removal of the
chassis.
6
EMRT1, EMWRT1
EMOCT
Save big on
energy without
compromising
guest comfort.
Introducing the New
Energy Management Solution
for Friedrich PTAC
Real Time Occupancy Sensor
EMRT1, EMWRT1
Friedrich’s EMRT1 and EMWRT1
thermostats use real-time
occupancy detection to save energy.
When the room is unoccupied, the
thermostat automatically adjusts
the temperature to eliminate
unnecessary heating and cooling.
Integrated Occupancy Sensor uses a combination of motion
and thermal sensing technologies for accurate occupancy
detection at all times - no need to install additional devices
such as door switches or sensors.
Wired or Wireless Installation
Wired or Wireless Connectivity with extensive configuration
options deliver full compatibility and easy integration with
virtually any packaged HVAC system.
5 Energy Savings Presets
5 distinct energy saving modes make it easy to choose the
optimal energy saving settings for any property.
Remote Management*
Web-based remote management provides expansive
solutions for remote monitoring and configuration from any
computer connected to the internet.
Remotely monitor energy use and evaluate
the performance of energy saving features.
Built-in Wireless Networking enables remote management
without using or interfering with property’s existing
wireless infrastructure. True mesh networking eliminates
the need for additional networking equipment such as
signal repeaters or multiple data collection boxes.
*Requires an optional “Online Connection Kit” and a one-time
license fee. See accessories page 6.
7
FriedrichLink® For Lodging
Monitor Room Status
See Energy Reports
Advanced Energy Saving Features
Fully configurable energy saving modes
maximize energy savings without
compromising guest comfort.
Room status displays operation,
occupancy and energy efficiency status
of each room.
Temperature setback automatically
adjusts the temperature when the room
is unoccupied in order to save energy.
Room detail displays temperature and
occupancy changes in a room.
Temperature recovery calculates the
setback temperature so that the desired
temperature can be restored within
specified time.
Setback optimization continuously
monitors temperature recovery rate in
the room and adjusts setback temperature to maximize energy savings.
Setback limits allow maximum and
minimum room temperature to be set
when the room is unoccupied.
Energy reports monitor energy use and
can even evaluate the performance of
energy saving features.
Intuitive interface makes it easy to apply
different settings to different rooms.
User management allows configuration
of custom access permissions and alert
notification settings for different users.
Built-in diagnostic tools automatically
send email alert notifications to hotel staff.
Set point limits prevent guests from
setting room temperature to extreme,
energy-wasting levels.
8
OPTIONAL ACCESSORIES
STANDARD GRILLE
PXGA
Standard, stamped, anodized aluminum to resist chalking
and oxidation.
PXGA
ARCHITECTURAL GRILLES
Architectural grilles that consist of heavy gauge 6063-T5 aluminum alloy.
PX AA Clear extruded aluminum.
PXBG Beige acrylic enamel.
PX SC Available in custom colors.
PXAA
DECORATIVE SUBBASE (black)
PXSBA
Provides unit support for walls less than six inches thick. Includes leveling
legs, side filler panels and mounting brackets for electrical accessories.
Accepts circuit breaker, power disconnect switch and conduit kit.
ELECTRICAL SUBBASE
Provides unit support for walls less than
six inches thick. Includes leveling legs,
side filler panels, mounting brackets,
a plug-in receptacle and field-wiring
access. The subbase also includes electrical knockouts for a power disconnect
switch or circuit breaker.
PXSB23020
Electrical Subbase - 230V 15 & 20A
PXSB23030
Electrical Subbase - 230V 30A
PXSB26515
Electrical Subbase - 265V 15A
PXSB26520
Electrical Subbase - 265V 20A
PXSB26530
Electrical Subbase - 265V 30A
POWER CORDS
Length
PXPC23015A
LCDI 230V 15A Cord - 2.5 kW
6 ft.
PXPC23020A
LCDI 230V 20A Cord - 3.5 kW
6 ft.
PXPC23030
LCDI 230V 30A Cord - 5.0 kW
6 ft.
PXPC26515A
Non-LCDI 265V 15A Cord - 2.5 kW
18 in.
PXPC26520A
Non-LCDI 265V 20A Cord - 3.5 kW
18 in.
PXPC26530
Non-LCDI 265V 30A Cord - 5.0 kW
18 in.
PXFTA
Antimicrobial air filters. 10 pack. Each PTAC requires 2 filters.
CONDENSATE DRAIN KIT
PXDR10
Attaches to the bottom of the wall sleeve for internal draining of condensate
or to the rear wall sleeve flange for external draining. Recommended for all
units to remove excess condensate. 10 pack.
LATERAL DUCT ADAPTER
PDXDAA
Attaches to the Friedrich PTAC/PTHP unit to direct up to 35% of the total
airflow to a second room. The unit-mounted duct plenum features a frontmounted aluminum grille that has two positions to provide the most optimal
air direction. The air may be directed to either the left or the right of the
unit through the supplied 3.5" H x 7" W x 47" L plenum. Plenum may be cut
to length by the installer. Kit includes duct plenum, front grille, 47" duct
extension, duct discharge grille, duct end cap and all necessary mounting
hardware.
LATERAL DUCT EXTENSION
PDXDEA
PDXDAA and PDXDEA ship together
Additional 3.5" H x 7" W x 47" L plenum for use with the LATERAL DUCT
ADAPTER. A maximum of three duct extensions total may be used. Note:
Ducted airflow is reduced as duct length is increased.
9
SPECIFICATIONS
PTAC Electric Heat models
PDE07K
PDE07R
PDE09K
PDE09R
PDE12K
PDE12R
PDE15K
PDE15R
PERFORMANCE DATA:
7200/7000
7200
9400/9200
9400
11800/11600
11800
14500/14200
14500
Cooling Watts
Cooling Btu
550/535
550
775/760
775
1015/1000
1015
1390/1365
1390
Energy Efficiency Ratio, EER
13.0/13.0
13.0
12.1/12.1
12.1
11.6/11.6
11.6
10.4/10.4
10.4
Moisture Removal (pints/hr)
1.7
1.7
2.1
2.1
2.7
2.7
3.1
3.1
Sensible Heat Ratio
0.86
0.86
0.85
0.85
0.75
0.75
0.67
0.67
ELECTRICAL DATA:
Voltage (1 PHASE, 60 Hz)
230/208
265
230/208
265
230/208
265
230/208
265
Volt Range
253-187
292-239
253-187
292-239
253-187
292-239
253-187
292-239
Current (Amps)
2.7/2.9
2.4
3.7/3.9
3.3
4.9/5.1
4.2
6.2/6.7
5.4
Power factor
0.97
0.97
0.97
0.97
0.97
0.97
0.97
0.97
Compressor LRA
13.0
12.5
19.5
13.5
21.5
19.0
28.9
21.6
Compressor RLA
2.5
2.2
3.5
3.0
4.7
3.9
5.9
5.05
0.080
0.080
0.080
0.080
0.086
0.086
0.086
0.086
Outdoor Fan Motor, HP
AIRFLOW DATA:
Indoor CFM, HIGH
345/315
345
355/325
355
400/390
400
400/390
400
Indoor CFM, LOW
270/255
270
300/275
300
325/310
325
325/310
325
75
75
75
75
75
75
75
75
Vent CFM
PHYSICAL DATA:
Sleeve Dimensions (H x W x D)
16” x 42” x 13 3/4” (all models)
Dimensions with Front (H x W x D)
16”x 42”x 21 1/2” (all models)
Cut Out Dimensions (H x W x D)
16 1/4”x 42 1/4” (all models)
Net Weight (lbs.)
106
107
115
115
119
118
121
121
Shipping Weight (lbs.)
126
127
135
135
139
138
140
140
R-410A CHARGE (oz)
23
23
24
24
36
36
36
36
Dimensions with Packaging (inches)
17 7/8" x 45" x 25 1/4" (all models)
PTAC Heat Pump models
PDH07K
PDH07R
PDH09K
PDH09R
PDH12K
PDH12R
PDH15K
PDH15R
PERFORMANCE DATA:
7200/7000
7200
9400/9200
9400
11800/11600
11800
14500/14200
14500
Cooling Watts
Cooling Btu
550/535
550
775/760
775
1015/1000
1015
1390/1365
1390
Energy Efficienct Ratio, EER
13.0/13.0
13.0
12.1/12.1
12.1
11.6/11.6
11.6
10.4/10.4
10.4
Reverse Heating Btu
6000/5800
6000
8300/8100
8300
10600/10400
10600
13300/13000
13300
Heating Watts
485/470
485
695/675
695
910/895
910
1255/1225
1255
COP
3.6/3.6
3.6
3.5/3.5
3.5
3.4/3.4
3.4
3.1/3.1
3.1
Moisture Removal (pints/hr)
1.7
1.7
2.1
2.1
2.7
2.7
3.1
3.1
SENSIBLE HEAT RATIO
0.86
0.86
0.85
0.85
0.75
0.75
0.67
0.67
ELECTRICAL DATA:
Voltage(1 PHASE, 60 Hz)
230/208
265
230/208
265
230/208
265
230/208
265
Volt Range
253-187
292-239
253-187
292-239
253-187
292-239
253-187
292-239
Current (Amps)
2.7/2.9
2.4
3.7/3.9
3.3
4.9/5.1
4.2
6.2/6.7
5.4
Reverse Heat. Amps
2.4/2.6
Power Factor
0.97
0.97
0.97
0.97
0.97
0.97
0.97
0.97
Compressor LRA
13.0
12.5
19.5
13.5
21.5
19.0
28.9
21.6
Compressor RLA
2.5
2.2
3.5
3.0
4.7
3.9
5.9
5.05
0.080
0.080
0.080
0.080
0.086
0.086
0.086
0.086
Outdoor Fan Motor, HP
2.2
3.4/3.2
3.1
4.2/4.7
3.7
6.2/6.7
5.0
AIRFLOW DATA:
Indoor CFM, HIGH
345/315
345
355/325
355
400/390
400
400/390
400
Indoor CFM, LOW
270/255
270
300/275
300
325/310
325
325/310
325
75
75
75
75
75
75
75
75
VENT CFM
PHYSICAL DATA:
Sleeve Dimensions (H x W x D)
16” x 42” x 13 3/4” (all models)
Dimensions with Front (H x W x D)
16”x 42”x 21 1/2” (all models)
Cut Out Dimensions (H x W x D)
16 1/4”x 42 1/4” (all models)
Net Weight (lbs.)
113
112
119
119
122
119
124
122
Shipping Weight (lbs.)
133
132
139
139
141
139
144
144
R-410A CHARGE (oz)
34
34
34
34
36
36
39
39
Dimensions with Packaging (inches)
17 7/8" x 45" x 25 1/4" (all models)
Due to continuing research in new energy-saving technology, specifications are subject to change without notice.
Warranty limited to installations in the United States, Puerto Rico, Mexico and Canada only.
See warranty documentation for full details.
LISTED
ULCDTP
ROOM AIR CONDITIONERS
183H
Friedrich Air Conditioning Co. l 10001 Reunion Place, Suite 500 l San Antonio, TX 78216 l 877.599.5665 www.friedrich.com
SG Series PTAC Brochure_2015
Printed in USA
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement