SECTOR Brochure
REMOTE
CONTROLS
PROXIMITY
ACCESS CONTROL
INTERCOMS
KEYPADS
SAFETY BEAMS
TH AFRIC
OU
IN
N
SLIDING GATE
OPERATORS
A
BARRIERS
AS
For the best
angle in high-volume
traffic barriers!
ITIATIVE
Lots of vehicles coming in and out? You need something that goes up and down. Fast!
The SECTOR is powered by a beefy custom-built DC motor and gearbox and can raise up
to a three metre boom pole at a blistering pace of less than 1.2 seconds.
Operating slightly slower, the SECTOR will effortlessly raise up to a six metre pole
smoothly and reliably.
The SECTOR lives fast – but it most definitely doesn’t die young.
Designed for tough, high-volume usage, it will work all day, it will work all night - lasting
for millions of cycles.
Add full battery backup, and the SECTOR is always at your service.
Main features
Rapid opening
Fast
Lots of vehicles coming in and out? You need something that
goes up and down. Fast!
The SECTOR is ideal for high-volume applications and puts a
manically ticking metronome to shame – raising a three metre
pole in under 1.2 seconds and lowering it just as quickly.
Battery backup
3000 times
for 24hr
With our 12V battery driven motor, your security is never
compromised. The SECTOR will continue to stay on, even
when the power is off – beating up and down 3000 times
during a 24 hour power failure before it needs a recharge.
If you're expecting no power for a while, the built-in mains
failure detection can be set to keep the barrier raised under
power failure conditions.
High-torque boom pole operation
Wind
The SECTOR's DC motor and reduction gearbox generate enough torque to make sure that your
boom goes up and down for ever and ever.
Come sunshine, rain or howling winds, you'll always be able to get in and out.
Safe sensitivity for boom pole lowering
Your boom won't go BOOM on the roof of a visitor's car. The SECTOR will detect any obstruction, so
you're safe – and won't have to fill out any of those pesky insurance forms.
Robust, durable and slim-line operator casing
Our slim SECTOR looks particularly fetching – and epoxy-coating, in a highly visible 'traffic yellow',
keeps it safe from drivers with terrible eyesight.
Available with different levels of corrosion protection for inland, coastal plains, and marine
environments.
Refer to 'Barrier housing specifications' on back page
3m
4.5m
6m
One size fits all
When size matters
Whether closing off an entrance from as narrow as three metres to as wide as six metres, there is a
SECTOR model to suit.
Fit the optional jack-knife and your SECTOR can even be fitted in areas with limited headroom.
Comprehensive input and output
With our intuitive, user-friendly LCD interface, setting up the SECTOR is not just simple - it's child's
play. Set the SECTOR to handle any vehicle access control application with the touch of a button.
To make things even easier, our state of the art motor controller not only ensures smooth and
reliable operation, it allows you to set your boom's opening and closing speed to your liking.
Integrated loop detector support
The SECTOR comes equipped to support both closing and free-exit loops. Simply plug in your
11-pin inductive vehicle loop detectors into the 11-pin sockets provided - connect the loops and
you're good to go.
BARRIERS
Operate wirelessly, thanks to CENTSYS1
Besides its code-hopping technology offering the highest level remote control security, this
CENTSYS onboard receiver is both multichannel and multi-user, allowing a multi-button remote to
operate any combination of the system inputs, such as Barrier Raise, Barrier Lower, etc.
It stores up to 500 transmitter buttons, and amongst other access control features, it provides the
ability to selectively add and delete transmitter buttons saved into its memory.
1. CENTSYS code-hopping
SECTOR controller features
Hardware features
&
&
&
&
&
&
&
Fully sealed plastic housing for controller to prevent ingress of dirt and insects
Easy setup of controller using LCD user interface
Removable connectors on controller for easy maintenance
Watchdog IC ensures full and safe operation of controller
Optional Backup Memory Module allows backing up of all the information that has been set up in the system
Standard pin plug-in bases pre-configured for approved 12V DC closing and free-exit inductive loop detectors
Adjustable and removable controller mounting tray for easy wiring and commissioning
Electronic features
&
&
&
&
&
&
&
&
&
&
&
&
&
&
&
Barrier raise and lower inputs
Memory and non-memory barrier activation
Onboard multichannel CENTSYS code-hopping with the ability to:
# learn transmitter buttons to specific functions (e.g. Barrier Raise, Barrier Lower, etc.)
# selectively delete specific transmitters that have been lost or stolen
# automatically learn transmitters (Autolearn) and
# automatically delete transmitters that are no longer in use
(Delete-Not-Present)
Full configuration of barrier operating parameters including
independent pole raise and lowering speeds, ramp-up and
ramp-down angles
Full configuration of barrier operating parameters including
independent pole raise and lowering speeds, ramp-up and
ramp-down angles
Automatic closing
Multiple Operating Profiles to suit region – select between ZA, CE, etc.
Multichannel controller with integrated ChronoGuard timer
technology (a world first)
Free-exit facility
Remote boom pole status indicator (pole position, power failure, low
battery, multiple collision detection and security light status indication)
Courtesy / Pillar Light Timer with adjustable duration
Fully configurable pre-delays with multi-modal pre-flash
Safety / Closing beam input with beam functional test
Lock / Emergency stop input
Ticket Vend Interlock
inductive loop detector or infrared beams must be fitted
remote LED must be fitted
infrared safety beams or equivalent detection
device must be fitted
an external pillar light must be connected to enable this feature
to use this feature, a normally-closed emergency
stop pushbutton must be fitted
an external light must be connected to enable this feature
this feature enables connectivity to a ticket vending
machine
BARRIERS
Technical specifications
SECTOR 3
Accessories
FLUX 11 12V
CLAWS
Required to enable the freeexit facility or the
closing/safety loop facility ground loop to be fitted
Add real security with
A traffic barrier pedestrian
seamless integration to our
fence that stops people from
SECTOR - available in Flush or circumventing the SECTOR
Surface mounted models
access control point
SECTOR 4.5 SECTOR 6
90V - 240V ± 10%, 50Hz
12V DC
Battery-driven (standard capacity - 7Ah)
CP84SM - 2A @ 13.8V
170mA
3.0m
4.5m
6.0m
1.2 sec
3 sec
3 sec
Allan key operated from outside unit
100%
Input voltage
Motor voltage
Motor power supply
Battery charger
Current consumption (mains)
Boom pole length
Boom pole raise/lower time (adjustable)
Manual override
Duty cycle - mains present
Operations in standby with 7Ah battery
Full day
Collision sensing
Operating temperature range
Onboard receiver type
Receiver code storage capacity
Receiver frequency
3000
Electronic
-15°C to +65°C
CENTSYS code-hopping multichannel
500 transmitter buttons
433MHz
Can operate off a solar supply, consult your local CentSys dealer for assistance
Battery capacity may be increased for longer standby times
Boom pole raise and lower times are both individually configurable to suit individual
installation requirements
Based on 25°C ambient temperature and unit not in direct sunlight
Based on a correctly-tensioned counterbalance spring
Based on basic operator excluding closing loop detector
TRAPEX
Barrier housing specifications
Coastal plains
-no airborne salt
Grade 430
Zinc-passivated
stainless steel
mild steel with
with epoxy
epoxy coating
coating
Application
Inland areas
Main housing surface protection
Breakaway Coupling
MIDI Traffic Light
Accommodates applications
with limited headroom
Pole hinges away from barrier if accidentally knocked
reducing the chance of being
damaged
Visually indicate when it is safe
for a vehicle to proceed into or
out of an access controlled
area
Grade 316
brushed
stainless steel
Grade 316
brushed
stainless steel
Sheet metal housing, 1.6mm wall thickness with
separate fabricated base frame, 3mm wall
thickness to raise housing above ground
Traffic yellow
IP 55
Mild steel, hot
dip galvanised
Base frame surface protection
Jack-knife assembly
Marine
areas
Housing construction
Colour
Housing protection rating
Mild steel, hot
dip galvanised
Barrier pole specifications
Aluminium, round profile with plastic end cap
Material and profile
Outside diameter: 76.2mm; Wall thickness: 1.27mm
Dimensions
800g/metre
Weight
Epoxy-coated white with red reflective tape
Surface protection, colour and markings
Backup Memory
Module Back up all the
CENTSYS transmitters
Available in one, two, three
and four button variants.
transmitters and operating
details set up in the controller Incorporates ultra-secure
code-hopping encryption
Manual pushbutton
Industrially rated switch,
typically for a guard to
manually activate the barrier
Overall dimensions
285mm
437mm
304mm
Ø76mm
SMARTGUARD or
SMARTGUARDair keypad
Gooseneck
Solar supply
Steel pole for mounting
intercom gate station or
access control reader
Alternative means of
powering the system - consult
your local CENTSYS dealer
for details
www.centsys.com.au
Centurion Systems (Pty) Ltd • South Africa
Contact number: +27 11 699 2400
Catchpost Allows locking
the boom pole in the lowered
position - recommended with
6m boom poles to support
pole tip and prevent drooping
due to flexure in the pole
890mm
1167mm
Proximity reader allowing for
Cost-effective and versatile
access to both pedestrians and wired and wireless keypad,
vehicles, while offering a higher
level of security than a keypad allowing access to pedestrians
20mm
SOLO/Lattice Proximity
Access Control System
Base frame
BARRIERS
ChronoGuard timer technology (a world first)
The SECTOR is so advanced it takes access control at the traffic barrier entrance to the next level.
With CENTSYS’ ChronoGuard timer technology onboard, any of the SECTOR’s inputs that activate the barrier can be set to
operate automatically or be time-barred at any time you choose. Its built-in Real Time Clock and Calendar timer allows you to set
up different exclusions, which can cater for public holidays, special Time-periods, etc. Once you’ve set up the SECTOR’s
ChronoGuard using the intuitive LCD screen on the controller, you’ll start feeling particularly redundant. For instance:
Gate
operational
Barrier
held
open
Barrier
operational
Lane 1
Lane 2
Very often, traffic barriers are used in conjunction with motorised gates at the entrances to
business parks, housing estates, etc. The traffic barrier controls access during the day when traffic
volumes are high, while the gate is used at night when greater security is required. ChronoGuard
can now be used to automatically switch operation from the SECTOR to the gate motor as and
when required. Security has never been this convenient.
Gate
held
open
Lane 3
To increase security and control traffic flow you can automatically shut down certain traffic lanes
controlled by the SECTOR at quieter times of the day, or over weekends and on holidays.
ChronoGuard gives you the ability to time-bar transmitters that have been learned into the
system. This gives you the flexibility to control when your barrier can be opened by specific
transmitter holders. For example, staff may be given access to the office park during the week, but
on weekends you may wish to limit their access to the property.
ChronoGuard technology allows for almost unlimited time-based functionality, all of which is very simply set up on the controller
via the intuitive menu system and LCD user interface. The following functionality is available:
& Time-activate many of the physical inputs and outputs of the controller (see table below)
& Time-bar many of the physical inputs and outputs of the controller, as well as particular remote buttons learned into the
onboard receiver (see table below)
& The Real Time Clock and Calendar timer has the following flexibility:
# It supports 100 Time-periods, that may be set according to:
# Weekdays (M + T + W + T + F) # Any day of the week (M, T, W, T, F, S, S)
# Every day of the week (M + T + W + T + F + S + S)
# Weekends (S + S)
# Special calendar events (family holiday, etc.) occurring on any date until the year 2100
# Annual calendar events (New Year’s Day, etc.)
# Allows for multiple Time-periods to be set during a 24-hour period
& The Real Time Clock and Calendar timer is backed up for at least one hour to maintain the current time and date in the event
that all power is removed from the controller
Physical inputs
MI:
Memory
input
NMI:
Non-memory
input
Raise:
Barrier
raise
Lower:
Barrier
lower
Lck/Stp:
Holiday
Lockout
ILP:
Inductive loop
detector
Physical outputs
Aux Out:
Aux IO:
Auxiliary
Auxiliary
output
input/ouput
Time-activate
Time-bar
Phys
Phys
Phys
Phys
Phys
physical connection to an external device, eg. Inductive Loop Detector, SMARTGUARD keypad, etc.
Phys
Phys
Phys
Phys
interfaces with onboard CENTSYS code-hopping receiver
Aux IO - open collector output that can be used to drive an external relay for operating any external device, eg. water feature, security lights, etc.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement