Cross Technologies 2017-04A Up+Downconverter, 140 MHz 950-2150 MHz (L-Band Modems) Data Sheet
PDF
Download
Document
Advertisement
Advertisement
DATA SHEET CROSS TECHNOLOGIES, INC. REV. 0 06/16/08 2017-04A Up/Downconverter, 950 - 2150 MHz The 2017-04A L-band Up/Downconverter converts 140 MHz to 950-2150 MHz (Up) and 950-2150 MHz to 140 MHz (Down) in 1 MHz steps with low group delay and flat frequency response. The 2017-04A has lower RF level out of the upconverter and higher RF level into the downconverter than the 2017-04 and is typically used to interface an L-band modem to a 140 MHz IF upconverter and downconverter. Multi-function push button switches select the RF frequency, gain, and other parameters. Front panel LEDs provide indication of DC power (green), PLL alarm for up and downconverters (red), remote operation (yellow), and Upconverter mute (yellow). Gain can be manually adjusted over a -25 to +15 dB range for the upconverter and over a 0 to +50 dB range for the downconverter by the front panel multi-function push-button switches. Remote operation allows selection of frequency and gain. Parameter selection and frequency and gain settings appear on the LCD display. Connectors are BNC female for IF and the optional external reference input and output, and Type F female for RF. A high stability (±0.01ppm) option is also available. It is powered by a 100-240 ± 10% VAC power supply and housed in a 1.75” X 19“ X 16” 1RU chassis. MODEL 2017 DOWNCONVERTER UPCONVERTER U F=2150 D F=1450 G=+10.0 G=+25.0 UP/DOWNCONVERTER MENU CROSS TECHNOLOGIES INC. EXECUTE ALARM REMOTE POWER MUTE ALARM Front Panel EQUIPMENT SPECIFICATIONS* ---------DOWNCONVERTER--------Input Characteristics (RF) Impedance/Return Loss 75 /12 dB Frequency 950 to 2150 MHz Noise Figure, max. 15 dB (max gain) Level -60 to -10 dBm 1dB compression -5 dBm Output Characteristics (IF) Impedance/Return Loss 75/18 dB Frequency 140 ± 36 MHz Level -10 to 0 dBm 1dB compression +5 dBm Channel Characteristics Gain range (adjustable) 0 to +50 dB, 1dB steps Image Rejection > 50 dB, min Frequency Sense Inverting or Non-inverting (selectable) ----------UPCONVERTER---------Input Characteristics (IF) Impedance/Return Loss 75 /18 dB Frequency 140 ± 36 MHz Level -40 to -10 dBm Output Characteristics (RF) Impedance/Return Loss 75/12 dB Frequency 950 to 2150 MHz Level -35 to -15 dBm 1dB compression -10 dBm Channel Characteristics Gain range (adjustable) -25 to +15 dB, 1dB steps Frequency Sense Non-inverting --------UP and DOWNCONVERTER-------Channel Characteristics Frequency Response ±1.5 dB, in band; ±0.5 dB, 36 MHz BW; ±0.75 dB, 72 MHz BW Spurious Response <-50 dBC Group Delay, max 0.0035 ns/MHz2 parabolic; 0.025 ns/MHz linear; 1 ns ripple Synthesizer Characteristics Frequency Accuracy ± 1.0 ppm internal reference (±0.01 ppm, option H) Frequency Step 1 MHz (125 kHz, option X) 10 MHz In/Out Level 3 dBm ± 3 dB Phase Noise @ Freq dBC/Hz Controls, Indicators Freq/Gain Selection Power; Alarm; Remote Remote Other RF Connector IF Connector 10 MHz Connectors Alarm/Remote Connector Size Power 100 Hz -75 1kHz -75 10kHz -85 100kHz -100 1 MHz -120 direct readout LCD; pushbutton switches or remote selection Green LED; Red LED; Yellow LED RS232C, 9600 baud Type F (female) BNC (female) BNC (female), 50/75 DB9 - NO or NC contact closure on Alarm 19 inch, 1RU standard chassis 1.75”high X 16.0” deep 100-240 ± 10% VAC, 47-63 Hz, 25 watts max Available Options E - External 10 MHz ref H - High Stability (±0.01ppm) internal ref Q - RS485 Remote Interface T - Temperature Sensor X - 125 kHz frequency step Connectors/Impedance B - 75 BNC (RF), 75 BNC (IF) C - 50 BNC (RF), 75 BNC (IF) D - 50 BNC (RF), 50 BNC (IF) J - 75 F-type (RF), 50 BNC (IF) N - 50 N-type (RF), 75 BNC (IF) M - 50 N-type (RF), 50 BNC (IF) *10˚C to 40˚C; Specifications subject to change without notice CROSS TECHNOLOGIES, INC. 6170 Shiloh Road, Alpharetta, Georgia 30005 770-886-8005, FAX 770-886-7964 www.crosstechnologies.com ">
Advertisement