5116B

5116B
Programmable transmitter
5116B
– Input for RTD, TC, mV, Ohm, potentiometer, mA and V
– 2-wire supply > 16.5 V to Ex zone 0
– Bipolar voltage input
– Output for current, voltage and 2 relays
– Universal supply by AC or DC
Application
• Linearized, electronic temperature measurement with RTD or
TC sensor.
• Conversion of linear resistance variation to a standard analog
current / voltage signal, i.e. from solenoids and butterfly
valves or linear movements with attached potentiometer.
• Power supply and signal isolator for 2-wire transmitters.
• Process control with 2 potential-free relay contacts which can
be configured for advanced functions.
• Galvanic separation of analog signals and measurement of
floating signals.
Connections
Technical characteristics
• Within a few seconds the user can program PR5116B to suit
the specific application.
• By way of the front push-button the input can be calibrated to
the exact span of the process. Zero drift on the process signal
can be adjusted by a single press of the front buttton.
• A green front LED indicates normal operation and
malfunction. A yellow LED is ON for each active output relay.
• Continuous check of vital stored data for safety reasons.
• 3-port 3.75 kVAC galvanic isolation.
Mounting / installation
• Mounted vertically or horizontally on a DIN rail. As the devices
can be mounted without any distance between neighboring
units, up to 42 devices can be mounted per meter.
This page is automatically generated on the basis of information provided on www.prelectronics.com and affiliated websites. It is provided to you as a service and for information
purpose only. While we have attempted to maintain the information as accurately as possible, the page may contain errors or omissions for which we disclaim any and all liability
Environmental Conditions
Specifications range.......................................
Calibration temperature.................................
Relative humidity............................................
Protection degree...........................................
-20°C to +60°C
20...28°C
< 95% RH (non-cond.)
IP20
Mechanical specifications
Dimensions (HxWxD).....................................
Weight approx................................................
Wire size........................................................
Screw terminal torque....................................
Vibration.........................................................
Vibration: 2...25 Hz........................................
Vibration: 25...100 Hz....................................
109 x 23.5 x 130 mm
235 g
1 x 2.5 mm2 stranded wire
0.5 Nm
IEC 60068-2-6 : 2007
±1.6 mm
±4 g
Current input
Measurement range.......................................
Min. measurement range (span)....................
Input resistance: Supplied
unit.................................................................
Input resistance: Non-supplied
unit.................................................................
Sensor error detection...................................
Voltage input
Measurement range.......................................
Measurement range.......................................
Min. measurement range (span)....................
Input resistance..............................................
Input resistance..............................................
Input resistance..............................................
0...100 mA
4 mA
Nom. 10 Ω + PTC 10 Ω
RSHUNT = ∞, VDROP < 6 V
Loop break 4...20 mA
0...250 VDC
-2500...+2500 mV
5 mV
Nom. 10 MΩ (≤ 2.5 VDC)
Nom. 5 MΩ (> 2.5 VDC)
> 5 MΩ (mV input)
Common specifications
Potentiometer via 2.5 V ref............................ 170 Ω
Supply
Supply voltage, universal............................... 21.6...253 VAC, 50...60 Hz or
19.2...300 VDC
Output specifications
Isolation voltage
Isolation voltage, test /
working........................................................... 3.75 kVAC / 250 VAC
Response time
Temperature input, programmable
(0...90%, 100...10%)...................................... 400 ms...60 s
mA / V input (programmable)......................... 250 ms...60 s
Auxiliary supplies
2-wire supply (pin 54...52).............................. 28...16.5 VDC / 0...20 mA
Fuse...............................................................
Max. power consumption...............................
Programming.................................................
Signal / noise ratio.........................................
Accuracy........................................................
400 mA SB / 250 VAC
≤3W
Loop Link
Min. 60 dB (0...100 kHz)
Better than 0.05% of selected
range
Signal dynamics, input................................... 22 bit
Signal dynamics, output................................. 16 bit
Auxiliary voltages: Reference
voltage............................................................ 2.5 VDC ±0.5% / 15 mA
EMC immunity influence................................ < ±0.5% of span
Extended EMC immunity: NAMUR
NE 21, A criterion, burst................................. < ±1% of span
Input specifications
Common input specifications
Max. offset...................................................... 50% of selected max. value
RTD input
RTD type........................................................
Cable resistance per wire
(max.).............................................................
Sensor current...............................................
Effect of sensor cable resistance
(3-/4-wire).......................................................
Sensor error detection...................................
Pt100, Ni100, lin. R
10 Ω (max. 50 Ω)
Nom. 0.2 mA
< 0.002 Ω / Ω
Yes
0...20 mA
10 mA
≤ 600 Ω
≤0.01% of span / 100 Ω
≤ 28 mA
Programmable 0...23 mA
23 mA / 3.5 mA
Voltage output
Signal range................................................... 0...10 VDC
Min. signal range............................................ 500 mV
Load (@ voltage output)................................ ≥ 500 kΩ
Relay output
Relay functions..............................................
Relay functions..............................................
Max. voltage...................................................
Max. current...................................................
Max. AC power..............................................
Max. load at 24 VDC......................................
Sensor error reaction.....................................
2-wire 4...20 mA output: Signal
range..............................................................
Load stability, 4…20 mA output.....................
Max. external 2-wire supply...........................
Effect of external 2-wire
supply voltage variation.................................
*of span..........................................................
Increasing / decreasing
Window
250 VRMS
2 AAC
500 VA
1A
Break / Make / Hold / None
4...20 mA
≤ 0.01% of span / 100 Ω
29 VDC
< 0.005% of span / V
= of the currently selected
measurement range
Observed authority requirements
EMC............................................................... 2014/30/EU
LVD................................................................ 2014/35/EU
PELV/SELV.................................................... IEC 364-4-41 and EN 60742
Approvals
ATEX 2014/34/EU.......................................... KEMA 04ATEX1316 X
FM.................................................................. 3023092
UL................................................................... UL 508
EAC................................................................ TR-CU 020/2011
EAC Ex TR-CU 012/2011.............................. RU C-DK.GB08.V.00410
DNV Marine.................................................... Stand. f. Certific. No. 2.4
5116B-042116
TC input
Thermocouple type........................................ B, E, J, K, L, N, R, S, T, U,
W3, W5, LR
Cold junction compensation
(CJC).............................................................. < ±1.0°C
Sensor error current....................................... Nom. 30 μA
Sensor error detection................................... Yes
Current output
Signal range...................................................
Min. signal range............................................
Load (@ current output).................................
Load stability..................................................
Current limit....................................................
Sensor error indication...................................
NAMUR NE 43 Upscale/Downscale..............