E-51:E-52 2/15/10 1:55 PM Page 1
Series 1620 – Single and Dual Pressure Switches
Specifications - Installation and Operating Instructions
Bulletin E-51
Ø9/32 [7.14]
MOUNTING HOLE
TYP 2 PLACES
1-1/2
[38.10]
5-7/8
[149.23]
8-7/8
[225.43]
8-1/4
[209.55]
7-3/4
[196.85]
1/2 CONDUIT
CONNECTION
45 ° TYP
Series 1620 Pressure Switch
3/4 [19.05]
1-5/16 [33.34]
4-11/16 [119.06]
3-1/16
[77.79]
INSTALLATION
1. Switch is normally calibrated for mounting in the vertical position with pressure and electrical connections pointing down. If other mounting is desired, it should be specified when ordering.
2. Two lugs with 9/32˝ diameter holes, 180 degrees apart on an 8-1/4˝ diameter circle are provided.
3. The location selected should be free from excessive vibration and ambient temperatures should not be above 130°.
OPERATION
1. General – Differential pressure acting on the power diaphragm rotates a channel, compressing a calibrated spring. The rotation of the channel actuates a snap switch when the set-point is reached, opening one set of electrical contacts and closing the other.
2. Pressure Connections – Two 1/8˝ NPT female connections are provided. Make appropriate connections as follows:
A. Differential Pressure – Connect tubing from source of greater pressure to high pressure port and from lower source to low pressure port.
B. Positive Pressure (above atmospheric) – Connect tubing from pressure source to high pressure port. Leave low pressure port vented to atmosphere.
C. Negative Pressure (vacuum) – Connect tubing from vacuum source to low pressure port. Leave high pressure port vented to atmosphere.
NOTE: When installing switch per paragraphs B or C in dusty environments, we recommend use of optional A-331 filter vent plug in the unused port. This will keep excess dirt from collecting inside switch.
3. Electrical Connections – Make wire connections for normally open or normally closed operation to appropriate screw terminals on snap switch.
ADJUSTMENT
1. If switch has been furnished pre-set, mount it vertically or horizontally as specified. Shifting the position of the switch will alter the set point. Because the setpoint may shift in transit it should be checked before placing it in service.
2. The effective area of either side of the power diaphragm is changed by the effect of the sealing diaphragm. Thus, the actuating differential pressure setting must be made with the total pressure for the service intended imposed on both sides of the diaphragm. For example, a switch set to close a circuit at a differential pressure increase to 1˝ of water with a total pressure of 1 PSIG will vary from the 1˝ of water setting if the total pressure is increased to 2 PSIG. Also, a two or three percent variation will be noted if a switch set for vacuum or below atmospheric pressure is used for pressure or above atmospheric pressure control.
3. To establish the set-point, use a manometer or pressure gage in an appropriate range and of known accuracy. Apply pressure slowly to allow equalization in all branches of the system. Keep tubing lengths as short as possible.
DWYER INSTRUMENTS, INC.
P.O. Box 373 • Michigan City, IN 46361-0373, U.S.A.
3 [76.20]
R 4-5/16 [109.54]
TYP 2 PLACES
1/8 FEMALE NPT
LOW PRESSURE
CONNECTION
SPECIFICATIONS
Service: Air and non-combustible, compatible gases.
Wetted Materials: Consult factory.
Temperature Limits: -30 to 130°F
(-34.4 to 54.4°C).
Pressure Limits: Max. 50 in. w.c.
(12.44 kPa) continuous, 2 psig (13.79
kPa) surge.
Switch Type: 1626, Single-pole double-throw (SPDT); 1627, two
Single-pole double-throw (SPDT) .
Repeatability: ±1%.
Electrical Rating: 15 A @ 120-480
VAC, 60 Hz. Resistive, 1/8 HP @ 125
VAC,1/4 HP @ 250 VAC, 60 Hz.
MODEL 1626, ALSO MODEL 1627 DUAL SWITCHES:
OPERATING RANGES, DEAD BANDS AND RATINGS.
Model (1626 shown, 1627 similar)
1626-1
1626-5
1626-10
1626-20
Operating
Range
Inches,
W.C.
.15 to 1.5
.5 to 6.0
2.0 to 11
8.0 to 24
Min.
.10
.15
.25
.50
Approximate
Dead Band
Max.
.20
.35
.65
1.20
Add –EXPL for explosion proof housing;
Add –WP for weather proof housing.
Phone: 219/879-8000
Fax: 219/872-9057
22.5
°
1/8 FEMALE NPT
HIGH PRESSURE
CONNECTION
Electrical Connections: 3 screw type, common, normally open and normally closed.
Process Connections: 1/8˝ female
NPT.
Mounting Orientation: Diaphragm in vertical position. Consult factory for other position orientations.
Set Point Adjustment: Screw
Adjustment.
Weight: Model 1626, 3 Ib, 9.8 oz (1.64
kg); Model 1627, 3 Ib, 11.8 oz (1.69
kg).
Agency Approvals: CE.
0.5
1.2
2.3
5.0
Adj. Diff.
Between Set
Points
(1627 only)
4. Model 1626 – The set-point is changed by turning the adjusting nut clockwise to increase and counter-clockwise to decrease. Model 1627 – The set-point of snap switch No. 2 is established first using the adjusting nut as with the 1626 series.
Next, set snap switch No. 1 by turning the adjusting screw under the switch roller.
Recheck switch No. 2 and correct as necessary. If switch No. 2 needs readjustment a final check of switch No. 1 should be made. The settings of the two switches affect one another and both should be checked any time either is changed.
MAINTENANCE
No unusual precautions are required. Care should be taken to keep the switch reasonably dry and free from dust or dirt. No lubrication required.
CAUTION: For use with air or compatible gases only.
www.dwyer-inst.com
e-mail: [email protected]
E-51:E-52 2/15/10 1:55 PM Page 2
SERIES 1620 – DIMENSIONS
SEALING DIAPHRAGM
CALIBRATED RANGE SPRING
ADJUSTING NUT
SNAP SWITCH
ADJUSTING NUT ADJUSTING SCREW
SEALING DIAPHRAGM
CALIBRATED RANGE SPRING
ADJUSTING NUT
ADJUSTING SCREW
SNAP SWITCH
ADJUSTING NUT
POWER
DIAPHRAGM
4-1/4
[107.95]
ø7/8 [22.23]
OPENING FOR
1/2˝ CONDUIT
FITTING
8-1/4
[209.55]
8-15/16
[227.01]
7-1/4
[184.15]
1/8 NPT
FEMALE
ø9/32 [ø7.14]
MOUNTING HOLES
POWER
DIAPHRAGM
4-1/4
[107.95]
ø7/8 [22.23]
OPENING FOR
1/2˝ CONDUIT
FITTING
8-1/4
[209.55]
8-15/16
[227.01]
7-1/4
[184.15]
1/8 NPT
FEMALE
ø9/32 [07.14]
MOUNTING
HOLES
OPTIONAL ENCLOSURES
Weatherproof Housing
Note: Pressure and electrical connections must face down when mounted.
1-1/4
(31.75)
7
(177.80)
8-13/16
(223.82)
TYP
1-5/16
(33.34)
2-21/64
(59.13)
1/8 FEMALE NPT
LOW PRESSURE
CONNECTION
1/8 FEMALE NPT
HIGH PRESSURE
CONNECTION
1/2 FEMALE NPT
ELECTRICAL CONNECTION
9-9/16 (242.89)
10-1/2 (266.70)
11-5/8 (295.28)
1/2 (12.70)
CLEARANCE
FOR COVER
REMOVAL
3-5/64 (78.18)
4-57/64
(124.22)
Explosion-proof Housing
Class I, Groups C & D; Class II, Groups E, F & G; Class III
Warning: To reduce the risk of ignition of the hazardous atmosphere, conduit seals must be installed within 18˝ of this enclosure.
Disconnect enclosure from supply circuit before opening. Keep assembly tight during operation.
3-1/2
(88.90)
Ø7/16 (11.11) MOUNTING
HOLE TYP 4 PLACES
1/8 FEMALE NPT
HIGH PRESSURE
CONNECTION
BREATHER
11
(279.40)
5-1/2
(139.70)
12-1/8
(307.98)
13-5/8
(346.08)
10-3/4 (273.05)
12 (304.80)
DRAIN
1/8 FEMALE NPT
LOW PRESSURE
CONNECTION
1-3/4 (44.45)
CLEARANCE FOR
COVER REMOVAL
3/4 FEMALE NPT
ELECTRICAL
CONNECTION
2-1/8
(53.98)
6
(152.40)
3-1/2
(88.90)
8-1/4
(209.55)
3/4
(19.05)
©Copyright 2010 Dwyer Instruments, Inc.
DWYER INSTRUMENTS, INC.
P.O. Box 373 • Michigan City, IN 46361-0373, U.S.A.
Printed in U.S.A. 2/10
Phone: 219/879-8000
Fax: 219/872-9057
FR# 21-440199-00 Rev. 5 www.dwyer-inst.com
e-mail: [email protected]
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project