acu25p (version 2)

acu25p (version 2)
CLEANING AND MAINTENANCE
CONTENTS
After spraying always flush out the backpack and lance with clean water and dispose
of the residues according to the product approval. Disconnect the lance from the
backpack at the flow tap and allow to dry thoroughly. Store in a clean dry place.
Description ............................................................................................................ 1
Safety .................................................................................................................... 2
Operator protection ................................................................................................ 2
Preparation of spray applicator ............................................................................... 3
Mixing and filling .................................................................................................. 4
Spraying ................................................................................................................ 5
AccuDos 25P parts list ........................................................................................... 6
AccuDos 25P parts diagram .................................................................................... 7
Cleaning and maintenance ...................................................................................... 8
Lubrication ............................................................................................................ 8
From time to time it will be necessary to lubricate the syringe and barrel on the
applicator with oil.
LUBRICATION
The applicator has the facility to lubricate without dismantling. If the syringe piston
becomes sluggish after prolonged use or after storage it will need oiling as below :1. Turn the knurled dose adjuster clockwise past the 25 ml setting until the word
‘oil’ appears. As the dial is set in this position the piston automatically moves
backwards slightly, engaging the oil position.
2. Introduce a few drops of vegetable oil (preferably olive oil BP) through the
aperture on the left hand side of the body so that the oil flows into the cavity
between the two piston seals. To avoid an air lock introduce the vegetable oil
using an oil can or dispenser with a fine nozzle.
3. To disengage the oil position squeeze the handle forward slightly and then turn
the dial anticlockwise. NB if the applicator is not disengaged from the oil
position in this way the lance may be damaged if force is used to turn the dial.
Page
DESCRIPTION
The AccuDos 25 is a spray applicator for the accurate dispensing and delivery of a
measured volume of spray liquid. The AccuDos 25 has the facility to ‘dial-in’ a predetermined quantity of spray liquid in 2.5 ml increments up to a maximum of 25 ml
per shot.
A choice of spray nozzles, specifically selected to deliver the appropriate spray
quality, are available to ensure that spray is transferred accurately to the target. An
anti-drip check valve is fitted as standard. The AccuDos 25 is supplied with a
purpose designed five litre Micropak backpack with a filter and large aperture to
facilitate ease of cleaning and filling. Liquid flow can be shut off with an in line tap
which allows for disconnection of the backpack and hand lance.
The syringe is not designed to be dismantled and when necessary should be replaced
entirely. Other parts are reusable i.e. aluminium spray lance system, nozzles, flow
tap and backpack (see parts list).
Choice of
spray nozzles
Metered volume
dispenser
300mm
aluminum lance
Wide filling opening
with leak-proof cap
5 litre
backpack
Flow control
valve
8
1
ACCUDOS 25P PARTS DIAGRAM
8
9
10
1
Using agrochemicals is a hazardous process. Operators should comply with all
relevant legislation and/or regulations governing the use of agrochemicals and should
use appropriate personal protective equipment (see ‘OPERATOR PROTECTION’).
Never use the AccuDos 25 in potentially explosive atmospheres or spray flammable
liquid through it.
Always read the product label carefully to discover:-
7
SAFETY
approved applications
2
maximum dose rates
maximum number of treatments
12
operator protection required
necessary environmental protection measures
16
N.B. ‘Dose rate’ refers to the amount of chemical product applied per hectare.
4
3
Never eat, drink, or smoke when working with agrochemicals. After using
agrochemicals or handling equipment wash your hands thoroughly. Keep people
(especially children) and animals out of areas being sprayed.
Always store agrochemicals safely to protect people and animals and to safeguard
the environment (take special care to avoid water pollution).
5
15
Always wear the protective clothing items listed on the product label for mixing and
filling. The minimum protective clothing required for spraying with the AccuDos 25
is:
6
OPERATOR PROTECTION
rubber gloves
boots/shoes and long trousers
eye protection
11
13
long sleeved shirt
2
7
ACCUDOS 25P PARTS LIST
PREPARATION OF SPRAY APPLICATOR
ITEM DESCRIPTION
NO.
1
NUT, UNION, 11/16" UNF P.P., NATURAL
2
NOZZLE BODY, 11/16" UNF - 1/4" BSP TAPER,
STRAIGHT P.P., NATURAL (MACHINED)
3
NUT, UNION, 1/4" BSP TAPER P.P., NATURAL
4
CONNECTOR, SYRINGE/LANCE, P.P., GREEN
5
ADAPTOR, LANCE, P.P., GREEN (SUPPLIED WITH ORING, BS007, VITON, BLACK)
6
SYRINGE APPLICATOR, 25 ML, GREEN
7
FILTER, BALL CHECK, 50 MESH, POLYACETAL WITH
STAINLESS STEEL MESH & BALL
8
NOZZLE, 110 DEGREE FLAT FAN, POLYACETAL, RED
9
NOZZLE, 110 DEGREE FLAT FAN, POLYACETAL,
BROWN
10 NOZZLE, HOLLOW CONE, HC05, POLYACETAL,
BROWN
11 SPRING, 0.5" O.D. X 0.048" WIRE
12 O-RING, BS 011, VITON
13 TUBE, PVC, 6 MM I.D. X 9 MM O.D. - 0.5 M
14 CLIP, HOSE, WIRE 9.1 MM
15 O-RING VITON
16 LANCE, 8 OD X 1 MM WALL - 0.30 M ALUMINIUM
BACKPACK AND REFILLING SYSTEM
17 BACKPACK, 5 LITRE
18 CAP ASSEMBLY
19 FILTER BOWL
20 TAP
21 HOSE CONNECTOR, 6 MM
22 UNION NUT
23 WEBBING, 50 MM, BLACK, POLYPROPYLENE
24 TUBE, PVC, 8 MM I.D. X 12 MM O.D. - 0.3 M
25 HOSE CLIP, NO. 12, WINGSCREW
26 CLIP, HOSE, WIRE 11.9 MM
18
20
14
21
19
PART NO.
QTY
5791
5792
1
1
5793
5795
5796
1
1
1
5797
5798
1
1
5848
5850
1
1
5856
1
5220
5151
4993/50
6028
6173
7633
1
1
1
1
1
1
5404
5208A
5449
5776A
5778
5779
5107/125
5414/30
5464
6029
1
1
1
1
1
1
2
1
1
1
13
23
17
22
25
24
6
26
1. First remove the hose pipe and flow
control valve stored inside the five
litre backpack. Connect the hose pipe
to the backpack and then connect the
spray lance to the flow control valve
according to the instructions contained
inside the backpack.
2. Fit the straps onto the backpack at the anchor points indicated.
3. Half fill the reservoir with clean water. Turn the dial on the hand lance to read 25
ml.
4. Holding the spray lance vertical to
point upwards, open the flow control
valve and then operate the trigger
mechanism until all the air has been
expelled from the syringe chamber
and lance.
Expel all air
5. Spray onto a dry surface to determine if the spread and spray pattern of the nozzle
is suitable.
6. If necessary, select an alternative
nozzle by unscrewing the union nut on
the nozzle adapter and inserting a
different nozzle.
The choice of nozzle will depend on the spray target. In general use a flat fan nozzle
if spraying bands or, for example, circles around trees. Hollow cone nozzle are better
suited to spot treatments of small areas or application of insecticides or fungicides.
Flat fan nozzles coded 110 give a 110° spread. When reassembling make sure that if
a flat fan nozzle is fitted it is positioned to deliver a fan pattern at right angles to the
operator’s line of travel.
3
MIXING AND FILLING
SPRAYING
Mixing and filling is generally the most hazardous process in the spraying operation.
Always follow the label instructions. Only mix enough spray for the area to be
treated thereby avoiding the need for disposal of unused spray mix.
The AccuDos 25 can be used for application of spot treatments to individual weeds or
patches of weeds. It can also be used for treating circles around trees or fence posts.
Experience will indicate the optimum volume to be dispensed for any given
application. The following table is a guide to the area which will be treated using
various volumes:
Area Treated Per Dose
Volume Applied (ml)
Always wear gloves when handling agrochemicals and equipment.
Always use the correct equipment when
mixing and measuring.
(m²)
cm x cm
circle diam
(cm)
5
0.1
30 x 30
36
10
0.2
45 x 45
50
15
0.3
55 x 55
62
20
0.4
63 x 63
71
25
0.5
70 x 70
80
The required quantity can be dialled in by
turning the knurled knob until the desired
volume is shown in the window. Turn the
knob clockwise to increase volume and
anticlockwise to decrease volume.
Al way s wa sh
contamination.
off
any
skin
Always clean all equipment after use.
When mixing chemicals follow the label instructions for use with a knapsack sprayer.
4
When spraying hold the nozzle 30 - 50 cm
from the target. If spraying circles around
trees it may be easier to spray two
semicircles rather than one complete circle.
5