Vaisala PTB210 Series Digital with Analog Output Barometer User's Guide
Below you will find brief information for Barometer PTB210 Series Digital with Analog Output. The PTB210 series digital barometers are designed for various pressure ranges. The barometers with an analog output are available with different scalings between 500...1300 hPa for 0...5V or 0...2.5V The PTB210 series barometers are also available with a digital output. The PTB210 series barometers offer an excellent solution for outdoor installations. They operate in a wide temperature range. The housing of the barometer electronics provides an IP65 standardized protection against sprayed water. The rugged corrosion-resistant housing in combination with the small size facilitates easy installation and a long lifetime for the barometer.
Advertisement
Advertisement
PTB210 Series Digital Barometers with Analog Output USER’S GUIDE U399EN-1.1 December 1999 PUBLISHED BY VAISALA Oyj P.O. Box 26 FIN-00421 Helsinki FINLAND Phone (int.): (+358 9) 894 91 Telefax: (+358 9) 894 9227 Telex: 122842 vsala fi Visit our Internet pages at http://www.vaisala.com/ © Vaisala 1999 No part of this manual may be reproduced in any form or by any means, electronic or mechanical (including photocopying), nor may its contents be communicated to a third party without prior written permission of the copyright holder. The contents of instruction manuals are subject to change without prior notice. _______________________________________________________________ GENERAL INFORMATION Do not delete this line. Table of contents CHAPTER 1 GENERAL INFORMATION ............................................................................3 Safety .........................................................................................3 Warranty ....................................................................................4 CHAPTER 2 PRODUCT DESCRIPTION.............................................................................5 CHAPTER 3 INSTALLATION ..............................................................................................7 Mounting....................................................................................7 Static pressure head..............................................................8 Connections ..............................................................................9 CHAPTER 4 CALIBRATION AND ADJUSTMENT ...........................................................10 Wizard software ......................................................................10 Operation .............................................................................11 CHAPTER 5 TECHNICAL DATA.......................................................................................15 Technical specifications ........................................................15 Operating range...................................................................15 Accuracy ..............................................................................15 General ................................................................................16 Electromagnetic compatibility ..............................................16 Dimensions .............................................................................17 VAISALA __________________________________________________________________________ 1 USER’S GUIDE_______________________________________________________________________ This page intentionally left blank. 2 ______________________________________________________________________ U399EN-1.1 CHAPTER 1_______________________________________________________ GENERAL INFORMATION CHAPTER 1 GENERAL INFORMATION Safety Throughout the manual, important safety considerations are highlighted as follows: WARNING Warning denotes a serious hazard. It calls attention to a procedure, practice, condition or the like, which, if not correctly performed or adhered to, could result in injury to or death of personnel. CAUTION Caution denotes a hazard. It calls attention to a procedure, practice, condition or the like, which, if not correctly performed or adhered to, could result in damage to or destruction of part or all of the product. NOTE Note highlights important information. It calls attention to an essential procedure, practice, condition or the like. VAISALA __________________________________________________________________________ 3 USER’S GUIDE_______________________________________________________________________ Warranty Vaisala hereby represents and warrants all Products manufactured by Vaisala and sold hereunder to be free from defects in workmanship or material during a period of twelve (12) months from the date of delivery save for products for which a special warranty is given. If any Product proves however to be defective in workmanship or material within the period herein provided Vaisala undertakes to the exclusion of any other remedy to repair or at its own option replace the defective Product or part thereof free of charge and otherwise on the same conditions as for the original Product or part without extension to original warranty time. Defective parts replaced in accordance with this clause shall be placed at the disposal of Vaisala. Vaisala also warrants the quality of all repair and service works performed by its employees to products sold by it. In case the repair or service works should appear inadequate or faulty and should this cause malfunction or nonfunction of the product to which the service was performed Vaisala shall at its free option either repair or have repaired or replace the product in question. The working hours used by employees of Vaisala for such repair or replacement shall be free of charge to the client. This service warranty shall be valid for a period of six (6) months from the date the service measures were completed. This warranty is however subject to following conditions: a) A substantiated written claim as to any alleged defects shall have been received by Vaisala within thirty (30) days after the defect or fault became known or occurred, and b) the allegedly defective Product or part shall, should Vaisala so require, be sent to the works of Vaisala or to such other place as Vaisala may indicate in writing, freight and insurance prepaid and properly packed and labelled, unless Vaisala agrees to inspect and repair the Product or replace it on site. This warranty does not however apply when the defect has been caused through a) normal wear and tear or accident; b) misuse or other unsuitable or unauthorized use of the Product or negligence or error in storing, maintaining or in handling the Product or any equipment thereof; c) wrong installation or assembly or failure to service the Product or otherwise follow Vaisala’s service instructions including any repairs or installation or assembly or service made by unauthorized personnel not approved by Vaisala or replacements with parts not manufactured or supplied by Vaisala; d) modifications or changes of the Product as well as any adding to it without Vaisala’s prior authorization; e) other factors depending on the Customer or a third party. Notwithstanding the aforesaid Vaisala’s liability under this clause shall not apply to any defects arising out of materials, designs or instructions provided by the Customer. This warranty is expressly in lieu of and excludes all other conditions, warranties and liabilities, express or implied, whether under law, statute or otherwise, including without limitation ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR OF FITNESS FOR A PARTICULAR PURPOSE and all other obligations and liabilities of Vaisala or its representatives with respect to any defect or deficiency applicable to or resulting directly or indirectly from the Products supplied hereunder, which obligations and liabilities are hereby expressly cancelled and waived. Vaisala’s liability shall under no circumstances exceed the invoice price of any Product for which a warranty claim is made, nor shall Vaisala in any circumstances be liable for lost profits or other consequential loss whether direct or indirect or for special damages. 4 ______________________________________________________________________ U399EN-1.1 CHAPTER 2_______________________________________________________ PRODUCT DESCRIPTION CHAPTER 2 PRODUCT DESCRIPTION The PTB210 series digital barometers are designed for various pressure ranges. The barometers with an analog output are available with different scalings between 500...1300 hPa for 0...5V or 0...2.5V. The PTB210 series barometers are also available with a digital output. The PTB210 series barometers offer an excellent solution for outdoor installations. They operate in a wide temperature range. The housing of the barometer electronics provides an IP65 standardized protection against sprayed water. The rugged corrosion-resistant housing in combination with the small size facilitates easy installation and a long lifetime for the barometer. All the barometers are digitally adjusted and calibrated by using electronic working standards. This manual gives the instructions for the use of PTB210 barometers with the analog output. 37%EDURPHWHU )L[LQJVFUHZSFV 5DLOIDVWHQLQJFOLS 3UHVVXUHILWWLQJ $WWDFKPHQWSODWH Figure 1 PTB210 and the standard accessories VAISALA __________________________________________________________________________ 5 USER’S GUIDE_______________________________________________________________________ The PTB210 barometers incorporate the BAROCAP® silicon capacitive absolute pressure sensor developed by Vaisala. The sensor features excellent hysteresis and repeatability characteristics and has an outstanding temperature and long-term stability. Silicon diaphragm Thin film metallization Silicon Glass Silicon Vacuum gap Figure 2 The BAROCAP® pressure sensor The BAROCAP® pressure sensor consists of two layers of single crystal silicon having a layer of glass between them. The thinner silicon layer creates an integrated vacuum reference chamber, and forms a pressure-sensitive silicon diaphragm. The thicker silicon layer is the rigid base plate of the sensor, and it is clad with a glass dielectric. Thin film metallization has been deposited to form a capacitor electrode inside the vacuum reference chamber. The other electrode is the pressure-sensitive silicon diaphragm. The coefficients of thermal expansion of silicon and glass materials used in the BAROCAP® pressure sensor are carefully matched together to minimize the temperature dependence, and to maximize the long-term stability. The BAROCAP® pressure sensor is designed to achieve zero temperature dependence at 1000 hPa, and its long-term stability has been maximized by thermal ageing at an elevated temperature. 6 ______________________________________________________________________ U399EN-1.1 CHAPTER 3______________________________________________________________ INSTALLATION CHAPTER 3 INSTALLATION Mounting Due to the compact design of the PTB210, all you need to do is to mount the instrument, and to connect the wires. Use one of the following three mounting options. - Remove the pressure fitting, and place the barometer on a desired structure. Then, fix it with the slot headed screws, the O-ring sealing the attachment (A). - Fix the supplied attachment plate to a desired place with a screw by using the hole on the vertical part of the plate. Then, attach the barometer on the plate with the screws supplied (B). - The PTB210 can also be placed to a standard rail (DIN 35) by using the attachment plate and clip (B). Fasten the clip and barometer to the plate with the screws supplied. Finally, attach the clip to a suitable rail. A Figure 3 NOTE B Different mounting options of the PTB210 Always place the barometer so that the pressure fitting is downwards. VAISALA __________________________________________________________________________ 7 USER’S GUIDE_______________________________________________________________________ NOTE Check that the cable is not taken upwards from the barometer. This is to prevent water flowing along the cable, and gathering close to the feed-through. Figure 4 Recommended cable position The IP65-classified housing enables the barometer to be mounted outdoors without any additional protection. However, please take care that rainwater cannot plug the open pressure fitting. In such conditions, it is recommended to connect a piece of a tube with inner diameter of 4 mm or more to the fitting. It is also possible to use a static pressure head, SPH10, which protects the pressure channel from rain, and minimizes the effect of wind. Static pressure head Please note that the pressure fitting supplied with the transmitter is not a static pressure head, and that the transmitter cannot be used successfully as such in turbulent or high-speed static wind conditions. In demanding wind conditions, it is recommended to use Vaisala’s static pressure head, SPH10, to which the PTB210 digital barometers can be directly integrated. This combination provides for accurate measurement in all wind conditions. 8 ______________________________________________________________________ U399EN-1.1 CHAPTER 3______________________________________________________________ INSTALLATION Connections Connect the wires of the PTB210 barometer according to Table 1. Use the pink wire for the supply voltage (8...18 VDC), and the blue wire for grounding. The output signal is read from the white wire and grounded with the brown wire. The gray and green wires are used to connect the barometer to PC when using the calibration Wizard software, or to Vaisala PMI20 digital barometer display. As a ground, use the blue wire. If an external power control is used, its signal wire is connected to the yellow wire. It is recommended to isolate the free wire ends. Table 1 Connections of the PTB210 barometer with analog output Wire color Signal Grey RX Green TX Blue Ground Pink Supply voltage (8...18 VDC) Brown Vout ground White Vout Yellow External power control (TTL level: 1 = off, 0 = on) VAISALA __________________________________________________________________________ 9 USER’S GUIDE_______________________________________________________________________ CHAPTER 4 CALIBRATION AND ADJUSTMENT The PTB210 series barometers can be fine adjusted and calibrated against pressure standards that have high accuracy and stability as well as known traceability to international standards. By comparing the output to a reference, the user can define the corrections required for readjustment. NOTE Calibration is considered not to involve any adjustments. It is advisable to write down the previous corrections so that they will not be lost by mistake. The corrections are given by using the Wizard software supplied. When the new corrections have been entered to the barometer, they are activated with the Wizard. Finally, the barometer is calibrated to verify its real accuracy. Wizard software The user-friendly Wizard software is designed to work in WIN3.X, WIN95, and NT environment. The two-point pressure corrections for the PTB210 barometers are given through the serial line by using this program. The calibration date can also be changed using the Wizard. 10 _____________________________________________________________________ U399EN-1.1 CHAPTER 4_________________________________________________ CALIBRATION AND ADJUSTMENT Operation • To start the Wizard program in NT: 1. Double-click the My Computer icon. 2. Double-click the drive that contains the file. 3. To start the program, double-click the WIZARD.EXE-file. OR • To start a program by using the Run command in NT 1. Click Start, and then click Run. 2. In the Open box, type the location and name of the program you want to start. Alternatively, browse the location, and choose the name of the program (WIZARD.EXE). Then, click OK. 1. Choose the COM port in use from the file menu. 2. To open the connection click the Read PTB210-button. VAISALA _________________________________________________________________________ 11 USER’S GUIDE_______________________________________________________________________ 3. Give reference pressure values and the corresponding corrections. Calculate the corrections according to the equations below. NOTE Because the lower end of voltage output is not exactly 0 V, use as lower calibration point a value approximately 40 mV above the lower end limit. Thus with scale 600…1060 hPa and 0…5V output the lowest calibration point will be 604 hPa. Pmeasured = Pmin + U out * ( Pmax − Pmin ) U out max corrnew = ( Preference − Pmeasured ) + corrprevious (1) (2) Example to calculate the higher end correction: Barometer scale 600…1060 hPa with the 0…5V output. - Output reading 4.8887 V - Pmeasured = 600 + [4.8887 * (1060-600)]/5 = 1049.76 hPa - Reference value 1050 hPa - Previous correction 0.22 hPa New correction (1050 - 1049.76) + 0.22 = 0.46 hPa NOTE The previous corrections have to be added to the new ones (see the example above). The correction at the lower end is calculated in similar way. The new calibration date can also be given. The values are given in hPa: the reference value as whole number, and the correction with two decimals. 12 _____________________________________________________________________ U399EN-1.1 CHAPTER 4_________________________________________________ CALIBRATION AND ADJUSTMENT 5HIHUHQFH &RUUHFWLRQ 4. To save the new corrections, click the Write PTB210-button. VAISALA _________________________________________________________________________ 13 USER’S GUIDE_______________________________________________________________________ 5. The program then asks a password. As default, no password exists. Just click OK. The password can be used to prevent saving of any new corrections without entering it. To give a password, click the Change-button. 6. Enter a new password and confirm by re-entering it. NOTE Remember to set the MPC corrections on after given them. 14 _____________________________________________________________________ U399EN-1.1 CHAPTER 5____________________________________________________________ TECHNICAL DATA CHAPTER 5 TECHNICAL DATA Technical specifications Operating range Pressure range (order specified) Operating temperature range Humidity range 500...1300 hPa 800...1060 hPa 600...1060 hPa 900...1100 hPa -40...+60°C non condensing Accuracy Non linearity* Hysteresis* Repeatability* Calibration uncertainty** Total accuracy (20°C)*** Temperature dependence (-40...+60°C)**** Total accuracy*** (-40...+60°C) Long term stability ± 0.20 hPa ± 0.05 hPa ± 0.05 hPa ± 0.15 hPa ± 0.30 hPa ± 0.50 hPa ± 0.60 hPa ± 0.10 hPa/year * Defined as the ±2 standard deviation limits of end-point nonlinearity, hysteresis error or repeatability error. ** Defined as ±2 standard deviation limits of inaccuracy of the working standard including traceability to NIST. VAISALA _________________________________________________________________________ 15 USER’S GUIDE_______________________________________________________________________ *** Defined as the root sum of the squares (RSS) of end-point nonlinearity, hysteresis error, repeatability error and calibration uncertainty at room temperature. **** Defined as ±2 standard deviation limits of temperature dependence over the operating temperature range. General Outputs (order specified) Supply voltage Current consumption normal mode shutdown mode Shutdown Response time Resolution Measurement rate Max. pressure Pressure connector Pressure fitting Housing electronics sensor Housing material Cable length Weight Instrument Cable 0...5 VDC 0...2.5 VDC 8 ... 18 VDC reverse polarity protected < 8 mA 0.2 mA ON/OFF 500 ms 300 9 3 measurement/s 5 000 hPa abs. M5 (10-32) internal thread barbed fitting for 1/8" I.D. tubing IP65 IP53 PC plastic 1, 2, 3, 5, or 10 m 110 g 28 g/m Electromagnetic compatibility Fully electromagnetically compatible according to standards: - EN 50081-1 Tested according to EN 55022 class B - EN 50082-1 Tested according to EN 61000-4-2, EN 61000-4-3 + ENV 50204, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6 16 _____________________________________________________________________ U399EN-1.1 CHAPTER 5____________________________________________________________ TECHNICAL DATA 122.5 (4.82) 32 (1.26) 16 (0.63) 120 (4.72) Dimensions in mm (inch) 50 (1.97) VAISALA _________________________________________________________________________ 17 USER’S GUIDE_______________________________________________________________________ £ [ £ [ 0 [£ [£ 0 0 18 _____________________________________________________________________ U399EN-1.1 ">

Public link updated
The public link to your chat has been updated.
Advertisement
Key features
- Analog output
- Wide operating temperature range
- Rugged weatherproof housing
- Digital adjustment and calibration
- BAROCAP® pressure sensor
- Excellent hysteresis and repeatability
- Outstanding temperature and long-term stability