Wireless switch unit RFSA-11B, RFSA-61B

Wireless switch unit  RFSA-11B, RFSA-61B
Wireless switch unit RFSA-11B, RFSA-61B
• The switching unit with 1 output channel is used to control appliances, lights (easy to integrate it to control
garage doors or gates).
• It can be combined with Control or System units iNELS RF Control.
60mm
21mm
• The BOX design lets you mount it right in an installation box, a ceiling or controlled appliance cover.
• It enables connection of the switched load up to 16A (4.000 W).
• RFSA-11B: single-function design - switch on / off
• RFSA-61B: multi-function design – button, impulse relay and time function of delayed ON or OFF with time
setting of 2s-60 min.
• The switching unit may be controlled by up to 32 channels (1 channel represents 1 button on the controller).
• The programming button on the unit is also used for manual control of the output.
• Range up to 200 m (in open space), if the signal is insufficient between the controller and unit, use the signal
RFSA-11B
RFSA-61B
repeater RFRP-20.
• Communication frequency with bidirectional protocol iNELS RF Control.
Technical parameters
RFSA-11B/230V
RFSA-61B/230V
RFSA-11B/120V
RFSA-61B/120V
RFSA-61B/24V
230 V AC / 50-60 Hz 120 V AC / 60Hz 12-24 V AC/DC 50-60Hz
Supply voltage:
7 VA / cos φ = 0.1 7 VA / cos φ = 0.1
Apparent input:
0.7 W
0.7 W
0.7 W
Dissipated power:
+10 %; -15 %
Supply voltage tolerance:
Output
1x switching (AgSnO2)
Number of contacts:
Rated current:
16 A / AC1
Switching power:
4000 VA / AC1, 384 W / DC
Peak current:
30 A / <3 s
Switching voltage:
250 V AC1 / 24 V DC
Max. DC switching power:
500 mW
Mechanical service life:
3x107
Electrical service life (AC1):
0.7x105
Control
RF, by command from transmitter:
868 MHz, 915 MHz, 916 MHz
Manual control:
PROG (ON/OFF) button
Range in free space:
up to 200 m
Other data
Operating temperature:
-15 to + 50 °C
Operating position:
any
Mounting:
free at lead-in wires
Protection:
IP 30
Overvoltage category:
III.
Contamination degree:
2
Terminals (CY wire, cross-section):
2x 0.75 mm2, 2x 2.5 mm2
Length of terminals:
90 mm
Dimensions:
49 x 49 x 21 mm
Weight:
46 g
Related standards:
EN 60669, EN 300 220, EN 301 489
R&TTE Directive, Order. No 426/2000 Coll. (Directive 1999/EC)
Function
For more information, see p. 56
Device description
Indication of operating
and programming mode
Program button
(ON/OFF manual control)
Neutral conductor
Phase conductor
Output relay contacts
Connection
RFSA-11B/230V
RFSA-11B/120V
RFSA-61B/230V
RFSA-61B/120V
L
N
RFSA-11B/230V
RFSA-11B/120V
RFSA-61B/230V
RFSA-61B/120V
L
N
RFSA-61B/24V
L
N
12-24 AC/DC
25
Switches
Single function RFSA-11B
Function button ON/OFF
The output contact closes by pressing one button position, and opens by pressing the other button position.
Multi function RFSA-61B, RFSA-62B, RFSA-61M, RFSA-66M, RFSAI-61B, RFSC-61, RFUS-61
Function 1 - button
Function 2 - switch on
Function 3 - switch off
The output contact will be closed by pressing the button and
opened by releasing the button.
The output contact will be closed by pressing the button.
The output contact will be opened by pressing the button.
Function 4 - impulse relay
Funcion 5 - delayed off
Function 6 - delayed on
The output contact will be switched to the opposite position
by each press of the button. If the contact was closed, it will be
opened and vice versa.
The output contact will be closed by pressing the button and
opened after the set time interval has elapsed.
t = 2s...60min.
The output contact will be opened by pressing the button and
closed after the set time interval has elapsed.
t = 2s...60min.
Loadability products
RFJA-12B; RFSA-62B; RFSA-66M; RFSTI-11/G; RFGSM-220M
Load type
Contact material AgSnO2
Contact 8A
cos φ ≥ 0.95
M
AC1
AC2
250V / 8A
250V / 5A
HAL.230V
AC3
AC5a without
compensation
AC5a with compensation
AC5b
AC6a
AC7b
AC12
250V / 4A
x
x
250W
250V / 4A
250V / 1A
250V / 1A
M
M
K
Load type
Contact material AgSnO2
Contact 8A
M
AC13
AC14
AC15
DC1
DC3
DC5
DC12
DC13
DC14
x
250V / 4A
250V / 3A
30V / 8A
24V /3A
30V / 2A
30V / 8A
30V / 2A
x
AC5a with compensation
230V / 3A (690VA)
up to max input C=14uF
AC5b
AC6a
AC7b
AC12
1000W
x
250V / 3A
x
M
M
RFUS-61
Load type
Contact material AgSnO2
Contact 14A
cos φ ≥ 0.95
M
M
AC1
AC2
AC3
AC5a without
compensation
250V / 14A
250V / 5A
250V / 3A
230V / 3A (690VA)
K
Load type
Contact material AgSnO2
Contact 14A
HAL.230V
AC13
AC14
AC15
DC1
DC3
DC5
DC12
DC13
DC14
x
250V / 6A
250V / 6A
24V / 10A
24V / 3A
24V / 2A
24V / 6A
24V / 2A
x
RFSA-11B; RFSA-61B; RFSA-61M; RFSTI-11B; RFDAC-71B , RFSC-61, RFSAI-61B
Load type
Contact material AgSnO2
Contact 16A
cos φ ≥ 0.95
M
56
HAL.230V
AC1
AC2
AC3
AC5a without
compensation
250V / 16A
250V / 5A
250V / 3A
230V / 3A (690VA)
K
Load type
Contact material AgSnO2
Contact 16A
M
AC5a with compensation
230V / 3A (690VA)
up to max input C=14uF
AC5b
AC6a
AC7b
AC12
1000W
x
250V / 3A
250V / 10A
M
M
AC13
AC14
AC15
DC1
DC3
DC5
DC12
DC13
DC14
x
250V / 6A
250V / 6A
24V 10A
24V /3A
24V /2A
24V / 6A
24V / 2A
x
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement