ATN Aries 6800c, 7800c, 8800c night vision scope User's guide
Below you will find brief information for night vision scope Aries 6800c, night vision scope Aries 7800c, night vision scope Aries 8800c. This user guide provides instructions on how to operate the Aries Defender night vision scope, which is a compact and lightweight weapon sight. The guide covers topics such as mounting, focusing, reticle brightness adjustment, IR illumination, cleaning, and troubleshooting.
Advertisement
Advertisement
Aries 6800c/7800c/8800c
“Defender”
u s e r ` s g u i d e
Export of night vision equipment and optical sighting equipment is controlled by the U.S. Department of State, Office of Defense
Trade Controls in accordance with International Traffic in Arms
(ITAR), Title 22, Code of Federal
Regulations Part 120-130and/or the
Export Administration Regulations
(EAR) U.S. Department of Commerce. Illegal export of these commodities is strictly prohibited.
AMERICAN
TECHNOLOGIES
NETWORK
CORP.
Battery housing
Lens fixation knob
Manual focus lens
5 Diopter
Elevation
Reticle brightness adjustment
Master power button
DIGITAL
INFRA-RED
ILLUMINATOR
FREE FOR YOUR
ARIES DEFENDER,
GUARDIAN AND
WARRIOR
SCOPE
Windage
Reticle system
Battery housing
Fixation screw
New Titanium mounting system
(mounts to std. U.S.
7/8” weaver rail)
IR brightness adjustment
IR elevation
IR focusing
IR windage
The information in this manual furnished for information use only, is subject to change without notice, is not to be construed as a commitment by ATN Corp.
ATN Corp. assumes no responsibility or liability for any errors or inaccuracies that may appear in this book.
©2005 ATN Corp. All right reserved.
2
The information in this manual furnished for information use only, is subject to change without notice, is not to be construed as a commitment by ATN Corp.
ATN Corp. assumes no responsibility or liability for any errors or inaccuracies that may appear in this book.
©2005 ATN Corp. All right reserved.
FEATURES
• The most compact and lightweight 2 nd , 3 rd or 4 th Generation weapon sight
• Optical configuration that surpasses current Military Specifications
• 3X magnification with new F1:1.2, f50mm lens
• “Red on Green” reticle system with 1/8 inch @ 100yards adjustment
• Automatic brightness control(ABC) for tube protection
• New Titanium mounting system
• Dimensions: 8”x3”x2.5”
• Weight: 2 lbs
• Made in USA
APPLICATION
The “c” in 6800c/7800c/8800c, stands for compact. The Aries
Defender is one of the most compact high-end night vision scopes you will ever find. Utilizing either a top grade US 2 nd Gen.
(6800c) tube, a high end US 3 rd Gen. (7800c) or a top grade
US 4 th Gen.(8800c) light intensifier tube the Defender has an extremely sharp resolution and brightness. This compact marvel is not a stripped down NVD it is full of features such as a new super fast front lens system for optimal brightness, easy push button operation, and a reticle brightness adjustment.
Plus, it comes with our new detachable, most powerful in the industry 450mw Infrared Illuminator with dedicated windage and elevation adjustments for total darkness usage.
“Red on Green” reticle system
PREPARATION FOR OPERATION
Before getting started make sure to follow these steps:
• Install the battery into its housing with the polarity order shown on the main body of the unit.
• Switch on the Aries scope with the protective lens cover still attached to the lens.
• Make sure that the green luminance of the light intensifier tube is present.
• Observe the scene, and adjust the diopter and/or lens for optimal image clarity.
• You may now enter a dark environment or simply shut the lights off in order to darken the room.
• Next, remove the lens cap/daylight filter.
• Observe the scene, and adjust the front lens for ideal focus.
• Finally, you may want to turn the infra red
(IR) illuminator on. Notice the ability of the
Aries scope to see in total darkness with the aid of the IR illuminator.
Battery installation
OPERATING
MOUNTING
1. Slightly loosen the horizontal and vertical fixing screws on the 7/8” weaver rail built into the scope.
2. Place the scope on the dovetail mount of the fire arm making certain that the mount aligns with the receptor attachment screw groove. Adjust as necessary.
3. Tighten the horizontal fixing screws.
NOTE: Receptor attachment screws may need to be tightened after continuous shooting.
2
MOUNTING SYSTEM
The ATN Night Vision Riflescopes Mounting
System allows to change the position of the riflescope flexibly on the weapon in relation to a shooter in combination with the fixed posi-
Rail with a fixing projection
Screws
Weaver rail
Grooves tions already available on the weaver rail.
For this purpose in the base of the mounting bracket there is a rail with a fixing projection.
There are three grooves in the mounting bracket for mounting this rail. Besides it is possible to change the position of the riflescope additionally by 1/3 of inch. For doing this one needs to about-face the rail.
To change the position of the riflescope on the weaver rail additionally follow the steps mentioned below:
1. Unscrew the two screws, which attach the rail to the mounting bracket.
2. Take the rail out of the groove.
3. About-face the rail in case of necessity.
4. Place the rail into another groove.
5. Fix the rail with the two screws.
NOTE: If the rail is not taken out easily, screw up tight one of screws into the threaded aperture in the middle of a fixing projection of the rail. Continue rotation of the screw. Thus the screw will push out a rail from a groove.
RETICLE BRIGHTNESS ADJUSTMENT
By rotating the knob you may adjust the reticle’s brightness. Adjustment could be easily seen if you look through the scope while adjustment.
FOCUSING
To focus your riflescope you will need to adjust the diopter first thing. Simply turn the diopter clockwise until it stops. Then, while looking through the diopter at a subject, slowly turn the diopter back counter clockwise until the grain in the image is sharp.
NOTE: We suggest that you focus the diopter during daylight with the filter on.
Before focusing turn the lens fixation handle clockwise, to unlock the lenses.
Next, focus the front lens until the image and the grain are both sharp. When you are in the low-light conditions and the daylight filter is off you may focus the front lens to receive a sharp image, the diopter should not be adjusted.
NOTE: The front lens should be readjusted as you view objects at different distances.
When you are finished to adjust the front lens focus, you should lock the front lens in place by turning the lens fixation knob clockwise. Failure to do this may cause shift in aimpoint when shooting.
3 4
3
IR ILLUMINATION
Infra-red (IR) Illuminators are common for night vision technology. The IR light greatly enhances the performance of your Aries scope, while remaining almost totally invisible to the naked eye. In dark environment, power up the Aries scope. Now, find a scene and examine it without the IR on then with IR powered up. Note the difference in illumination. It is important to remember that the IR illuminator is simply an infra red light source, and like any light source it may loose its effectiveness over a great distance.
To fix the IR Illuminator to the riflescope screw the thumb screw on the IR into the thread on the scope. To switch the IR on and to adjust the brightness rotate the rheostat located on the side of the Illuminator. The changes of adjustment could be observed while looking through the scope. The IR is off when the mark on the rheostat coincides with “0” on the scale.
Battery
Housing
IR Brightness
Adjustment
NOTE: The riflescope could be equipped with digitally controlled IR.
The IR illuminator control buttons are located on its side. To switch the Digital IR illuminator on/off press “+” and “-” buttons simultaneously. When the IR illuminator is switched on you can see the green LED lit.
By pushing the buttons “+” and “-” you may adjust the IR brightness.
The IR beam is focusable to change the field of coverage. To change the beam width slightly turn the IR lens.
You could change the IR control panel fitting your needs. The screw-tool included into the set should be used for weakening the fixing screw located on the IR. Rotate the IR placing at in the most convenient position.
Tighten the screw with the screw-tool to fix the new position.
IR Elevation
IR Focusing
Fixation
Screw IR Windage
RANGEFINDER RETICLE
Aries Defender reticle gives a clearly aiming point, even when hard-to-see game blends into the background. Thinner posts and crosshairs center section covers a mininmum of the targer and allow for less target coverage, making precision shot on small targets easy.
Heavy posts stans out against cover and leads your eye directly to the center intersection. The result is fast precision aiming.
The thin lines correspond to 2,5 yards at 100 yards distance
WINDAGE AND ELEVATION
Windage
Elevation
The vertical and horizontal adjustments for the Aries can be achieved by turning the elevation and windage adjustment mechanisms (remove dust caps first). Each click equals 1/8 inch at 100 yards . When reaching the maximum range of rotation do not use force.
4
5
CLEANING THE EYEPIECE
You may need to clean the eyepiece of the riflescope from time to time in order to guarantee top performance. When you receive your riflescope you should check for dust on the eyepiece of the unit.
First you will need to remove the eyepiece.
To do that you will need to initially loosen the
2 set screws that can be found on the base.
Then unscrew the eyepiece counter-clockwise to remove it.
NOTE: You do not have to remove the set screws completely, they are very small and easy to misplace.
CAUTION: Use only Photographic lens cleaning tissue on these surfaces. Be careful not to scratch or smudge any of these surfaces.
When using compressed air to blow dust away, make sure to avoid inverting the can while spraying. This can cause frozen propellant to exit the can, which can cause serious problems with the glass and phosphor screen.
WARNINGS AND
CAUTIONS
• Always remember to turn off the Aries scope when it is not in use. If you do not plan on using your aries scope for a period of more than 10 days, you should remove the batteries.
• Keep lens cap/daylight filter on when not in use.
• Avoid contact with dust, steam, and gas.
• The Aries scope are not harmful to the user or the environment.
• Do not disassemble except to clean the front lens and the eyepiece: it will void your warranty.
• Evaluate the scopes function by looking through it in a lit environment with the daylight filter lens cap on. Never use in daylight without the daylight filter lens cap on. Do not surpass ten minutes of testing.
• Never point the Aries scope at a bright light source. If the scope shuts off automatically after directing it at a bright light source, turn the unit off and wait 1 - 2 minutes before turning the unit back on.
• Adverse atmospheric conditions such as fog, smog, or haze and a lack of ambient light (moon or starlight) may diminish the effective viewing distance. All technical data for this unit was compiled in a controlled environment.
TROUBLESHOOTING
Q: Flashes, flickers, or clicking occur while operating
S: If it occurs within the first five minutes of inserting new batteries, it is normal and the device will resume normal operation soon thereafter. If it occurs for more than 10 minutes, contact your dealer or other authorized service representative for service instructions.
Q: Dark spots on screen.
S: This may be dust on the lens, please clean according to instrutions. They may also be Cosmetic blemishes in the intensifier tube which are a by-product of the manufacturing process. This is normal and will not affect the life or performance of the unit.
Q: Image not clear.
S: Adjust focus ring. If problem persists, increase viewing distance
Q: Fixed-pattern noise in a honeycomb shape.
S: Usually a cosmetic blemish characterized by a faint honeycomb-type pattern. This usually occurs when viewing very bright lights. Adjust the potentiometer, to reduce brightness.
Q: A pattern of dark thin lines which look like chicken wire.
S: Turn on illuminator, if purchased. If illuminator doesn’t brighten image, replace batteries. If problem persists, contact ATN for service instructions.
6
5
2 YEAR PRODUCT
WARRANTY
This product is guaranteed to be free from manufacturing defects in material and workmanship under normal use for a period of 2 (two) years from the date of purchase.
In the event a defect that is covered by the foregoing warranty occurs during the applicable period stated above, ATN, at its option, will either repair or replace the product, and such action on the part of ATN shall be the full extent of ATN’s liability, and the Customer’s sole and exclusive remedy.
This warranty does not cover a product (a) used in other than its normal and customary manner; (b) subjected to misuse; (c) subjected to alterations, modifications or repairs by the Customer of by any party other than
ATN without prior written consent of ATN;
(d) special order or “close-out” merchandise or merchandise sold “as-is” by either ATN or the ATN dealer; or (e) merchandise that has been discontinued by the manufacturer and either parts or replacement units are not available due to reasons beyond the control of ATN. ATN shall not be responsible for any defects or damage that in ATN’s opinion is a result from the mishandling, abuse, misuse, improper storage or improper operation, including use in conjunction with equipment which is electrically or mechanically incompatible with or of inferior quality to the product, as well as failure to maintain the environmental conditions specified by the manufacturer. CUSTOMER IS HEREBY
NOTIFIED THAT OPERATION OF THE
EQUIPMENT DURING DAYLIGHT HOURS
OR UNDER ANY EXCESSIVE LIGHT CON-
DITIONS MAY PERMANENTLY DAMAGE
THE INTERNAL COMPONENTS OF THE
UNIT AND SAID DAMAGE WILL NOT BE
COVERED UNDER THIS WARRANTY.
This warranty is extended only to the original purchaser. Any breach of this warranty shall be waived unless the customer notifies
ATN at the address noted below within the applicable warranty period.
The customer understands and agrees that except for the foregoing warranty, no other warranties written or oral, statutory, expressed or implied, including any implied warranty of merchantability or fitness for a particular purpose, shall apply to the product. All such implied warranties are hereby and expressly disclaimed.
LIMITATION OF LIABILITY
ATN will not be liable for any claims, actions, suits, proceedings, costs, expenses, damages or liabilities arising out of the use of this product. Operation and use of the product are the sole responsibility of the Customer.
ATN’s sole undertaking is limited to providing the products and services outlined herein in accordance with the terms and conditions of this Agreement. The provision of products sold and services performed by ATN to the Customer shall not be interpreted, construed, or regarded, either expressly or implied, as being for the benefit of or creating any obligation toward any third party of legal entity outside ATN and the Customer; ATN’s obligations under this
Agreement extend solely to the Customer.
ATN’s liability hereunder for damages, regardless of the form or action, shall not exceed the fees or other charges paid to ATN by the customer or customer’s dealer. ATN shall not, in any event, be liable for special, indirect, incidental, or consequential damages, including, but not limited to, lost income, lost revenue, or lost profit, whether such damages were foreseeable or not at the time of purchase, and whether or not such damages arise out of a breach of warranty, a breach of agreement, negligence, strict liability or any other theory of liability.
PRODUCT WARRANTY
REGISTRATION
In order to validate the warranty on your product, ATN must receive a completed
Product Warranty Registration Card for each unit. Please complete the form below and immediately mail it to our Service Center:
ATN Corporation, 20 South Linden Ave.,
Suite 1B, South San Francisco CA 94080.
Products qualifying for warranty repair will be either repaired or replaced within 10 business days of receipt of merchandise unless the customer is notified otherwise.
OBTAINING WARRANTY SERVICE
To obtain warranty service on your unit, take or send the product, postage paid, with a copy of your sales receipt to our service center, ATN Corporation at the address noted above. All merchandise must be fully insured with the correct postage; ATN will not be responsible for improper postage, or, missing or damaged merchandise during shipment.
6
For customer service and technical support, please contact
American Technologies Network Corp.
North American Office
20 S. Linden Ave. Suite 1B, South San Francisco, CA 94080 phone: 800-910-2862, 650-875-0130; fax: 650-875-0129
European Office phone: 44(0)870-0111286, fax: 44(0) 845-3349142
The following countries can use our toll free number 00 800 9102-8620
Austria, France, Germany, Holland, Italy, Spain, Sweden, Switzerland www.atncorp.com
©2005 ATN Corporation
Advertisement
Key features
- Compact and lightweight
- 3X magnification
- Super fast front lens system
- Detachable IR illuminator
- Automatic brightness control
- Titanium mounting system