マニュアル 英語(PDF:433.22KB)
[Startup and Maintenance Precautions]
Mitsubishi General-Purpose Programmable Controller
Renewal Tool
Conversion Adapter
WARNING

Do not touch live terminals. There is a danger of electric shock or malfunction.

Shut off the external power supply for the system in all phases before cleaning or
retightening the terminal screws. Failure to do so may result in electric shock or cause the
MELSEC-Q Series module to fail or malfunction. Loose screws can lead to dropping,
shorting, and malfunction. Excessive tightness of the screws can lead to breakage of the
screws, Conversion Adapter, or MELSEC-Q Series Module, possibly causing the dropping,
shorting, and malfunction thereof.
Model
ERNT-AQTB38-E
User’s Manual

50CM-D180199-A(1509)
Do not modify the Conversion Adapter or take it apart. Doing so will cause failure,
malfunction, personal injury, or fire.
ERNT-AQB68
Do not drop the Conversion Adapter or do not give a strong impact to it. This will cause
damage.
ERNT-AQB65
(Always read these precautions prior to use.)
Before using this product, please read this manual carefully and pay full attention to safety to ensure that
the product is used correctly.
The precautions presented in this manual are concerned with this product only. For Programmable
Controller system safety precautions, refer to the user’s manual of the MELSEC-Q series CPU module to
be used.
In this manual, the safety precautions are ranked as “WARNING” and “CAUTION.”
970
382×240
795
247×240
675
466×240
930
352×240
790
Q63B Q52B(*5) ERNT-AQF3
ERNT-AQF8
238×240
411×240
650
870
ERNT-AQF5
297×240
655
Q52B(*5) ERNT-AQF3
183×240
505
Q33B
Q612B
Q68B(*2)
Q68B(*2)
Q65B(*3)
Q55B(*4)
Q68B(*2)
ERNT-AQF5
Q65B(*3)
Q55B(*4)
ERNT-AQB52
4.Product Specifications
EMC AND LOW VOLTAGE DIRECTIVES
 SAFETY PRECAUTIONS 
480×240
Q35B
ERNT-AQB55
When disposing of the product, treat it as industrial waste.
ERNT-AQF12, ERNT-AQF8
ERNT-AQF8
ERNT-AQF8, ERNT-AQF5
ERNT-AQF5
ERNT-AQF3
ERNT-AQF12, ERNT-AQF8
ERNT-AQF8
ERNT-AQF8, ERNT-AQF5
Q38B(*1)
Q38B(*1)
ERNT-AQB62
ERNT-AQB58
[Disposal Precautions]

Q312B
ERNT-AQB32
CAUTION
HEAD OFFICE: Hulic KUDAN BLDG.1-13-5,KUDANKITA CHIYODA-KU,TOKYO 102-0073,JAPAN
NAGOYA ENGINEERING OFFICE:139 SHIMOYASHIKICHO-SHIMOYASHIKI,KASUGAI,AICHI 486-0906,JAPAN
ERNT-AQB38
ERNT-AQB35
CAUTION

(2) Base Adapter (Sold Separately)
Both the MELSEC-Q series base unit and the conversion adapter anchor base can be installed on the
base adapter without drilling screw holes.
However, drilling screw holes (M5 screws) is required to install the base adapter to the panel surface.
For the base unit models marked with *1 to *5, two or more base adapter models are applicable.
Select the most suitable base adapter according to the product dimensions.
Product
Installable
dimensions Weight
Base adapter
model
MELSEC-Q Series base unit
Conversion Adapter Width×Height (g)
(mm)
Anchor Base
12 slots 8 slots
5 slots 3 slots 2 slots
Compliance to the EMC Directive, which is one of the EU Directives, has been a legal obligation
for the products sold in European countries since 1996 as well as the Low Voltage Directive
since 1997.
Manufacturers who recognize their products are compliant to the EMC and Low Voltage
Directives are required to declare that print a "CE mark" on their products.
For the details of specifications of the MELSEC-Q series modules not described herein, refer to the user's manual of
the applicable MELSEC-Q series module. Also, check that the specifications of the connected devices meet
the specifications of the MELSEC-Q series module.
(1) MELSEC-Q Series module
Product
Shape
Quantity
Product
Shape Quantity
CAUTION
Conversion Adapter
MIN
3.2
※The minimum length is 5.0 mm when the solderless terminal is attached up side down as shown below.
Terminal block
Model
●Terminal block shape
-
Number of output points
Isolation method
Rated load voltage
Maximum load current
Maximum inrush current
Leaked current at OFF
Unit:mm
1
Before attempting to install the Unit or carry out the necessary wiring, make certain that the
external power supply, used in the system, is shut off on all three phases. Failure to do so may
result in electric shock or damage to the product.
After installation and wiring, close the terminal block cover before turning on the module for
operation. Failure to do so may result in electric shock.
CAUTION
Carry out wiring for the Conversion Adapter correctly after checking the specification and
terminal arrangement for the module used. Connecting a power supply with a different
voltage rating or incorrect wiring may cause a fire or failure.
Tighten the terminal installation screws and terminal screw securely by applying torque
within the specified limits. Loose screws will cause short circuit, fire or malfunction.
Excessive tightening will damage the screws or the Conversion Adapter which in turn will
cause dropping of parts, short circuit or malfunction.
Use care to prevent foreign materials including cuttings and wiring debris from entering the
Conversion Adapter or the MELSEC-Q Series Module. These will be cause for fire, failure
or malfunction.
Vibration
resistance
Maximum voltage drop at ON
7.2
Specifications
0 to 55℃(Maximum surrounding air temperature 55℃)
Response OFF to ON
time
ON to OFF
Surge suppressor
Fuse
Protection function
Internal current consumption
Common terminal arrangement
4.75 3.5
-25 to 75℃
(3) Internal connection
5 to 95%RH,non-condensing
Frequency
[Wiring Precautions]
WARNING
8.6
2.General Specifications
Item
Operating ambient
temperature
Storage ambient
temperature
Operating ambient
humidity
Storage ambient
humidity
Compliant with
Under
5 to 8.4Hz
JIS B 3502 intermittent
8.4 to 150Hz
and
vibration
IEC 61131-2
Under
5 to 8.4Hz
continuous
8.4 to 150Hz
vibration
ERNT-AQTB38-E
Constant
Half
acceleration amplitude
-
3.5mm
9.8m/s2
-
-
1.75mm
4.9m/s2
-
Sweep count
10 times each in
X, Y, Z directions
-
Compliant with JIS B 3502 and IEC 61131-2
(147 m/s2, 3 times each in 3 directions X, Y, Z)
Operating atmosphere
No corrosive gases
Operating altitude *1
0 to 2000m
Installation location
Inside a control panel
Overvoltage category *2
II or less
Pollution degree *3
2
*1:Do not use or store under pressure higher than the atmospheric pressure of altitude 0m.
*2:This indicates the section of the power supply to which the equipment is assumed to be connected between
the public electrical power distribution network and the machinery within premises.
Category II applies to equipment for which electrical power is supplied from fixed facilities.
*3:This index indicates the degree to which conductive material is generated in terms of the environment in
which the equipment is used.
Pollution level 2 is when only non-conductive pollution occurs. A temporary conductivity caused by
condensing must be expected occasionally.
Shock resistance
Terminal
block
TB2
TB4
TB6
TB8
TB10
TB12
TB14
TB16
TB18
TB20
TB22
TB24
3.Products Required by the Conversion Adapter
(1) Conversion Adapter Anchor Base (Sold Separately)
The conversion adapter anchor base secures the bottom of the conversion adapter. One anchor
base is required per base unit.
Conversion Adapter Anchor Base model
Specifications
Weight (g)
ERNT-AQF12
12-slot conversion adapter anchor base
590
ERNT-AQF8
8-slot conversion adapter anchor base
410
ERNT-AQF5
5-slot conversion adapter anchor base
275
ERNT-AQF3
3-slot conversion adapter anchor base
185
TB1
Y00
TB2
Y01 TB3
Y02
TB4
Y03 TB5
Y04
TB6
Y05 TB7
Y06
TB8
Y07 TB9
Y08
TB10
Y09 TB11
Y0A
TB12
Y0B TB13
Y0C
TB14
Y0D TB15
Y0E
TB16
Y0F TB17
Y10
TB18
Y11 TB19
Y12
TB20
Y13 TB21
Y14
TB22
Y15 TB23
Y16
TB24
Y17 TB25
Y18
TB26
Y19 TB27
Y1A
TB28
Y1B TB29
Y1C
TB30
Y1D TB31
Y1E
TB32
Y1F TB33
COM
TB34
Open TB35
0V
TB36
Open TB37
Open
TB38
Open
12/24VDC
Terminal
No.
TB1
TB2
TB3
TB4
TB5
TB6
TB7
TB8
TB9
TB10
TB11
TB12
TB13
TB14
TB15
TB16
TB17
TB18
TB19
TB20
TB21
TB22
TB23
TB24
TB25
TB26
TB27
TB28
TB29
TB30
TB31
TB32
TB33
TB34
TB35
TB36
TB37
TB38
QX81
(Negative common)
32 points
Photocoupler isolation
24VDC (+20/-15%)
Approx. 4mA
19V or higher/3mA or higher
11V or lower/1.7mA or lower
Approx. 5.6kΩ
1/5/10/20/70ms or less
1/5/10/20/70ms or less
QX80
(Negative common)
32 points
Photocoupler isolation
24VDC (+20/-15%)
Approx. 6mA
15V or higher/3mA or higher
5V or lower/1.7mA or lower
Approx. 3.6kΩ
1/5/10/20/70ms or less
1/5/10/20/70ms or less
75mA(TYP. all points ON)
75mA(TYP. all points ON)
32 points/common
32 points/common
②Output module
1
M3 screw
 Use the Conversion Adapter in the environmental conditions that are specified in the general
specification. If the Products are used in any environment beyond the bounds of the general
specification, electric shock, fire, malfunction, or damage to or degradation of the Products will
result.
 Do not directly touch any conductive parts of Conversion Adapter. Contact will cause
malfunction or failure in the system.
 Fasten the Conversion Adapter securely with retaining screws, and tighten the screws by
applying torque within specified limits. Loose screws can lead to the dropping of the
Conversion Adapter, possibly causing breakage thereof. Excessive tightness of the screws
can lead to breakage of the screws, Conversion Adapter, or MELSEC-Q Series Module,
possibly causing the dropping, shorting, and malfunction thereof.
 When installing or removing the MELSEC-Q Series Module complete with a Converter
Adapter, be sure to hold it with both hands. Dropping may lead to breakage.

Terminal block
This manual
CAUTION

MAX 3.5
Model
Specification
Number of input points
Isolation method
Rated input voltage
Rated input current
ON voltage/ON current
OFF voltage/OFF current
Input resistance
Response OFF to ON
time
ON to OFF
Internal current
consumption
Common terminal
arrangement
Specification
[Installation Precautions]

1
Y-shaped solderless terminal
with an insulation sleeve
MIN 3.2(※)
MIN 3.2(※)
Solderless terminal
 When making a switch to the MELSEC-Q Series, be sure to consult user's manual supplied
with individual module under the MELSEC-Q Series to confirm differences in various aspects
including performance, function, CPU input/output signals between the two modules.

MIN
φ3.2
MAX 3.5
Once you have opened the packaging, verify that it contains the following products.
[Precautions before using]

MIN 3.2(※)
MIN
φ3.2
Y-shaped non-insulated
solderless terminal
MIN
3.2
MIN 3.2(※)
Round-shaped solderless terminal
with an insulation sleeve
MAX
7.2
Note that failure to observe the
CAUTION level instructions may lead to a serious consequence
according to the circumstances. Always follow the precautions of both levels because they are important
to personal safety.
Please keep this manual in an easy-to-access location for future reference, and be sure to provide the
manual to the end user.
Round-shaped non-insulated
solderless terminal
Unit:mm
MAX
7.2
Indicates that incorrect handling may cause hazardous conditions,
resulting in medium or minor injury and/or property damage.
Terminal
block
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
①Input module
●Applicable solderless terminal
This manual describes specifications, handling and other information about the Conversion Adapter
“ERNT-AQTB38-E” available as Renewal Tools for the Mitsubishi General-Purpose Programmable
Controller.
Before attempting to make a switch to MELSEC-Q Series in your installation, consult the user's
manual supplied with individual module under the latter series to learn about how they differ in various
aspects including performance and function.
QY81P
Signal
name
X00
X01
X02
X03
X04
X05
X06
X07
X08
X09
X0A
X0B
X0C
X0D
X0E
X0F
X10
X11
X12
X13
X14
X15
X16
X17
X18
X19
X1A
X1B
X1C
X1D
X1E
X1F
COM
Open
Open
Open
Open
Open
(5) MELSEC-Q Series module specification
MAX
7.2
CAUTION
1.Overview
Terminal
No.
TB1
TB2
TB3
TB4
TB5
TB6
TB7
TB8
TB9
TB10
TB11
TB12
TB13
TB14
TB15
TB16
TB17
TB18
TB19
TB20
TB21
TB22
TB23
TB24
TB25
TB26
TB27
TB28
TB29
TB30
TB31
TB32
TB33
TB34
TB35
TB36
TB37
TB38
QY81P
MAX
7.2
WARNING
24VDC
QX81-S2
(2) Specifications of the terminal block (conversion adapter accessory)
Indicates that incorrect handling may cause hazardous conditions,
resulting in death or severe injury.
TB1
X00
TB2
X01 TB3
X02
TB4
X03 TB5
X04
TB6
X05 TB7
X06
TB8
X07 TB9
X08
TB10
X09 TB11
X0A
TB12
X0B TB13
X0C
TB14
X0D TB15
X0E
TB16
X0F TB17
X10
TB18
X11 TB19
X12
TB20
X13 TB21
X14
TB22
X15 TB23
X16
TB24
X17 TB25
X18
TB26
X19 TB27
X1A
TB28
X1B TB29
X1C
TB30
X1D TB31
X1E
TB32
X1F TB33
COM
TB34
Open TB35
Open
TB36
Open TB37
Open
TB38
Open
MELSEC-Q Series module model
QX81
Input
Output
Authorized representative in Europe is shown below.
Name: Mitsubishi Electric Europe BV
Address: Gothaer strasse 8, 40880 Ratingen, Germany
Terminal
block
The conversion adapter can be used in combination with the following MELSEC-Q series modules.
Input/Output
Authorized representative in Europe
(4) External connection
QX81,QX81-S2
TB26
TB28
TB30
TB32
TB1
TB3
TB5
TB7
TB9
TB11
TB13
TB15
TB17
TB19
TB21
TB23
TB25
TB27
TB29
TB31
TB33
TB34
Open TB35
TB36
Open TB37
Open
TB38
Open
TB34 and TB36 to TB38
are open terminals.
TB1
TB2
TB3
TB4
TB5
TB6
TB7
TB8
TB9
TB10
TB11
TB12
TB13
TB14
TB15
TB16
TB17
TB18
TB19
TB20
TB21
TB22
TB23
TB24
TB25
TB26
TB27
TB28
TB29
TB30
TB31
TB32
TB33
TB34
TB35
TB36
TB37
TB38
1
20
2
21
3
22
4
23
5
24
6
25
7
26
8
27
9
28
10
29
11
30
12
31
13
32
14
33
15
34
16
35
17
36
18
37
19
MELSEC-Q Series
module
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
37
36
35
34
33
32
31
30
29
28
27
26
25
24
23
22
21
20
QY81P
(Source type)
32 points
Photocoupler isolation
12 to 24VDC (+20/-15%)
0.1A/point,2A/common
0.7A 10ms or less
0.1mA or less
0.1VDC (TYP.)0.1A
0.2VDC (MAX.)0.1A
1ms or less
1ms or less(rated load,resistive load)
Zener diode
No
Yes(overload protection,overheat protection)
80mA(TYP. all points ON)
16 points/common
Signal
name
Y00
Y01
Y02
Y03
Y04
Y05
Y06
Y07
Y08
Y09
Y0A
Y0B
Y0C
Y0D
Y0E
Y0F
Y10
Y11
Y12
Y13
Y14
Y15
Y16
Y17
Y18
Y19
Y1A
Y1B
Y1C
Y1D
Y1E
Y1F
COM
Open
0V
Open
Open
Open
5.Mounting and Installation
7.External Dimensions
5.1 Handling Precautions
Unit:mm
Conversion adapter
Terminal block
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
204
(1) Before attempting to install the Unit or carry out the necessary wiring, make certain that the
external power supply, used in the system, is shut off on all three phases. Failure to do so may
result in electric shock or damage to the product.
(2) Do not touch live terminals. There is a danger of electric shock or malfunction.
(3) Do not modify the Conversion Adapter or take it apart. Doing so will cause failure, malfunction,
personal injury, or fire.
(4) Do not touch the energized part of the Conversion Adaptor directly. Contact will cause
malfunction or failure in the system.
(5) Fasten the Conversion Adapter securely with retaining screws, and tighten the screws by
applying torque within specified limits. Loose screws can lead to the dropping of the Conversion
Adapter, possibly causing breakage thereof. Excessive tightness of the screws can lead to
breakage of the screws, Converter Adaptor, or MELSEC-Q Series Module, possibly causing the
dropping, shorting, and malfunction thereof.
(6) Use care to prevent foreign materials including cuttings and wiring debris from entering the
Conversion Adapter or the MELSEC-Q Series Module. These will be cause for fire, failure or
malfunction.
(7) Do not drop the Conversion Adapter or do not give a strong impact to it. This will cause damage.
18
19
20
21
22
23
24
25
26
27
28
29
5.2 Use Precautions
Item
30
31
Width dimension of module
The module width dimension is 27.4
mm. Check the conditions for wiring
space and installation.
32
Depth dimension
The depth dimension required for
installation is 165.3 mm. Check the
installation condition.
33
34
35
36
37
38
Conversion adapter
Use
Precautions
31
Base adapter
Conversion adapter
anchor base
165.3
153.5(※)
27.4
※When the base adapter is
not used
5.3 Installation Environment
The installation environment is the same as MELSEC-Q series CPU Module to use. Refer to the user's
manual of the MELSEC-Q Series CPU Module to be used.
27.4
Weight:225g
Duplication Prohibited
This manual may not be reproduced in any form, in part or in whole, without written permission from
Mitsubishi Electric Engineering Company Limited.
©2015 MITSUBISHI ELECTRIC ENGINEERING COMPANY LIMITED ALL RIGHTS RESERVED
MELSEC is a registered trademark of Mitsubishi Electric Corporation.
6.Part Names and Installation Method
MELSEC-Q series module
Conversion adapter installation screw
M2.6 x 20
2
Terminal block installation screw
(M4)
3
Precaution
5
Terminal block
(conversion adapter accessory)
3
Conversion adapter anchor base
Conversion adapter
Existing wiring
Conversion adapter
bottom installation screw
M3 x 20
1
6
4
Conversion adapter anchor base installation screw
M4 x 8 (conversion adapter anchor base accessory)
5
Terminal block screw (M3)
6.1 Installation Method
Product Warranty Details
Please confirm the following product warranty details prior to product use.
① Secure the conversion adapter anchor base to the base adapter or control panel using the
conversion adapter anchor base installation screws (M4  8) provided as an accessory. (Two end
locations)
Gratis Warranty Terms and Gratis Warranty Range
② Mount the conversion adapter onto the MELSEC-Q series module.
If any fault or defect (hereinafter referred to as “Failure”) attributable to Mitsubishi Electric Engineering
Company Limited (hereinafter referred to as “MEE”) should occur within the gratis warranty period,
MEE shall repair the product free of charge via the distributor from whom you made your purchase.
③ Secure the conversion adapter using the conversion adapter installation screws (M2.6  20; 2
 Gratis Warranty Period
locations).
Precaution
Before tightening the installation screws, check that the Conversion Adapter has been
securely installed on the MELSEC-Q Series module. Tightening the screws in floating-off
state or tilting state will damage the Conversion Adapter installation screws and the
MELSEC-Q series module.
④ Secure the conversion adapter using the conversion adapter bottom installation screw (M3  20;
1 location).
⑤ Secure the terminal block to the conversion adapter using the terminal block installation screws
(M4; two upper/lower locations).
⑥ Connect the existing wiring to the terminal block.
When any wires are left unconnected, connect them to open terminals or insulate them.
6.2 Tightening Torque
Tighten the installation screws to the specified torque below. An inappropriate tightening torque could
cause the product to fall or result in a short circuit, product failure or malfunction.
Screw Location
Tightening Torque Range
Conversion adapter anchor base installation screw (M4×8)
1.39 to 1.89N・m
Conversion Adapter installation screw (M2.6×20)
0.34 to 0.46N・m
Conversion Adapter bottom installation screw (M3×20)
0.43 to 0.57N・m
Terminal block installation screw (M4 screw)
1.02 to 1.38N・m
Terminal block screw (M3 screw)
0.43 to 0.57N・m
The gratis warranty period of this product shall be one (1) year from the date of purchase or
delivery to the designated place.
Note that after manufacture and shipment from MEE, the maximum distribution period shall be six
(6) months, and the gratis warranty period after manufacturing shall be limited to eighteen (18)
months.
In addition, the gratis warranty period for repaired products shall not exceed the gratis warranty
period established prior to repair.
 Gratis Warranty Range
The gratis warranty range shall be limited to normal use based on the usage conditions, methods
and environment, etc., defined by the terms and precautions, etc., given in the instruction manual,
user’s manual and caution labels on the product.
Warranty Period after Discontinuation of Production
(1) MEE shall offer product repair services (fee applied) for seven (7) years after production of the
product has been discontinued. Discontinuation of production shall be reported via distributors.
(2) Product supply (including spare parts) is not possible after production has been discontinued.
Exclusion of Opportunity Loss and Secondary Loss from Warranty
Liability
Regardless of the gratis warranty period, MEE shall not be liable for compensation for damages arising
from causes not attributable to MEE, opportunity losses or lost profits incurred by the user due to
Failures of MEE products, damages or secondary damages arising from special circumstances,
whether foreseen or unforeseen by MEE, compensation for accidents, compensation for damages to
products other than MEE products, or compensation for other work carried out by the user.
Changes in Product Specifications
The specifications given in the catalogs, manuals and technical documents are subject to change
without notice.
This document is a new publication, effective September 2015. Specifications are subject to change
without notice.
Developed September 2015