VC L 2 1 1 G 2 02

VC L 2 1 1 G 2 02
Direct Operated 2 Port Solenoid Valve
For Oil
Series VCL
Series VC
How to Order Valves (Single Unit)
VX2
VXD
VC L 2 1
1 G
2
02
VXZ
VXE
For oil
Option
Nil
F
∗ Bracket is packed in the same container
as the main body.
Series
2
3
4
VXP
None
Foot type bracket
Class 2
Class 3
Class 4
VXH
Material and insulation type
Symbol Body material Seal material Coil insulation type
Nil
Class B
Brass (C37)
D
Class H
FKM
H
Class B
Stainless steel
N
Class H
Valve type
N.C.
2
Thread type
1
VX3
N
F
Voltage
VCHm
Rc
NPT
G
Nil
100 VAC
200 VAC
110 VAC
220 VAC
24 VDC
12 VDC
240 VAC
48 VAC
230 VAC
VXF
VXA
1
1
2
3
4
5
6
7
8
J
VXR
VDW
VQ
Port size
∗ Class B in AC has a rectifying circuit
built-in.
∗∗ Class H is AC only. No rectifying circuit.
∗∗∗ Please consult with SMC regarding
other voltages.
Symbol
01
02
03
04
06
Class 2
v
v
—
—
—
Port size
1/8 ( 6A)
1/4 ( 8A)
3/8 (10A)
1/2 (15A)
3/4 (20A)
Class 3
—
v
v
v
—
LVM
Class 4
—
v
v
v
v
VCA
VCB
VCL
Electrical entry
G – Grommet
C – Conduit
Orifice diameter
Symbol Orifice dia. (mmø) Class 2
v
2
2
v
3
3
v
4
4
v
5
5
—
7
7
—
10
10
Class 3
—
v
v
v
v
v
VCS
Class 4
—
v
v
v
v
v
VCW
∗ Refer to the below table for orifice and port size combinations.
T – Conduit terminal
D – DIN terminal
DL – DIN terminal with light
DO – DIN terminal
(without connector, with gasket)
Orifice diameter and Port Size Combinations
Class
2
3
Connector
∗ All class B coils come with surge voltage suppressor.
∗∗ Available types of electrical entry for type H coil are either
G, C and T.
(Surge voltage suppressor, light are not equipped.)
4
Port size
Orifice diameter (mmø)
2
3
4
5
7
10
1/8 ( 6A)
V
V
V
V
—
—
1/4 ( 8A)
V
V
V
V
— —
1/4 ( 8A)
—
V
V
V
V
—
3/8 (10A)
—
V
V
V
V
V
1/2 (15A)
—
— —
— —
V
1/4 ( 8A)
—
V
V
V
V
—
3/8 (10A)
—
V
V
V
V
V
1/2 (15A)
—
— —
— —
V
3/4 (20A)
—
— —
— —
V
333
Series VCL
Specifications
Standard specifications
Valve construction
High temperature specifications
Direct operated poppet
Fluid
Oil [50 mm2/s] or less
Valve specifications
Withstand pressure (MPa)
5.0
Body material
Brass (C37), Stainless steel
Seal material
FKM
Ambient temperature (°C) Note 1)
Fluid temperature (°C)
Note 1)
–20 to 60
–20 to 100
–10 to 60 (No freezing)
–10 to 100
Enclosure
Dusttight, Low jetproof (IP65)
Environment
Location without corrosive or explosive gases
Valve leakage (cm3/min)
Exterior leakage
0.1 or less (with oil pressure)
(cm3/min)
0.1 or less (with oil pressure)
Mounting orientation
Unrestricted
Vibration/Impact resistance (m/s2) Note 3)
30/150 or less
24 VDC, 12 VDC, 48 VAC, 100 VAC, 110 VAC,
200 VAC, 220 VAC, 230 VAC, 240 VAC (50/60 Hz)
Rated voltage
±10% of rated voltage
Coil specifications
Allowable voltage fluctuation
Coil insulation type
Class H
Class B
Power consumption
DC
VCL20: 6 W, VCL30: 8 W,
VCL40: 11.5 W
Note 2)
VCL20: 8.5 VA
Apparent power
48 VAC, 100 VAC, 200 VAC, 220 VAC,
230 VAC, 240 VAC (50/60 Hz)
Inrush
VCL20: 22/19 VA
VCL30: 36/30 VA
VCL40: 45/37 VA
Holding
VCL20: 10/8 VA
VCL30: 15/13 VA
VCL40: 19/16 VA
VCL30: 10 VA
AC 50/60 Hz
VCL40: 13 VA
Note 1) When the ambient temperature or fluid temperature is 60°C or more, use high
temperature specifications (class H coil).
Note 2) Since a rectifier circuit is used for class B coils with AC, there is no difference in
apparent power between inrush and holding.
Note 3) Vibration resistance ···· Conditions when tested with one sweep 10 to 250 Hz in the
axial direction and at a right angle to the armature, in both
energized and deenergized states. No malfunction occurred
when tested. (Value at the initial state)
Impact resistance ···· Conditions when tested with a drop tester in the axial direction
and at a right angle to the armature, one time each in energized
and deenergized states.
No malfunction occurred when tested. (Value at the initial state)
Characteristic Specifications
Note 1)
N.C.
Flow characteristics Max.system
Note 1)
Orifice
Max.operating
Model Class Port size diameter
pressure
pressure differential
-6
2
Cv
(MPa)
Av x 10 (m )
(MPa)
(mmø)
converted
VCL2
VCL3
VCL4
2
3
4
1/8 ( 6A)
1/4 ( 8A)
1/4 ( 8A)
3/8 (10A)
1/2 (15A)
1/4 ( 8A)
3/8 (10A)
1/2 (15A)
3/4 (20A)
2
1.5
3.8
0.16
3
0.8
7.9
0.33
4
0.4
12
0.51
5
0.25
16
0.65
3
1.5
4
0.8
13
0.54
5
0.5
19
0.80
8.4
2.0
1/8 : 0.21
1/4 : 0.24
2.0
1/4 : 0.42
3/8 : 0.40
1/2 : 0.49
2.0
1/4 : 0.58
3/8 : 0.55
1/2 : 0.62
3/4 : 0.78
0.35
7
0.2
33
1.4
10
0.1
50
2.1
3
2.0
4
1.1
14
0.60
5
0.7
20
0.85
7
0.3
33
1.4
10
0.12
50
2.1
8.4
Note 2)
Mass
(kg)
0.35
Note 1) Refer to page 333 in model selection regarding port size and orifice diameter combinations.
Note 2) The mass is the value for the grommet type.
334
Direct Operated 2 Port Solenoid Valve
For Oil
Series VCL
Construction
q
w
VX2
e
VXD
r
VXZ
VXE
Component Parts
t
y
1
2
3
4
5
6
7
u
IN
VXP
Material
Description
No.
Option
Standard
Clip
Tube assembly
Stainless steel
—
Stainless steel, Cu
Ag
Coil assembly
Armature assembly
Class B
Class H
Stainless steel, FKM, PPS (Class B only)
—
FKM
—
O-ring
Return spring
Body
Stainless steel
—
Brass (C37)
Stainless steel
VXR
VXH
VXF
VX3
Refer to pages 314 and 315 for solenoid coil replacement and replacement parts.
VXA
VCHm
Dimensions: Bracket
VDW
A
VQ
J
4 x øG
C
LVM
1.5
VCA
VCL
L
E
D
B
VCB
VCS
VCW
4 x øH
Valve mounting hole
F
Bracket Mounting Dimensions/Bracket Material: Stainless Steel
(mm)
Valve model
Port size
Bracket part no.
A
B
C
D
E
F
G
H
J
L
VCL2l
1/8, 1/4
VCW20-12-01A
34
40
25
30
12.8
12.8
5
4.5
6
13
1/4, 3/8
VCW30-12-02A
42
52
30
40
19
19
6
5.5
7
19
1/2
VCW30-12-04A
48
56
36
44
23
23
6
5.5
7
23
1/4, 3/8
VCW40-12-02A
42
52
30
40
23
23
6
5.5
7
19
1/2
VCW30-12-04A
48
56
36
44
23
23
6
5.5
7
23
3/4
VCW40-12-06A
56
65
44
53
28.2
28.2
6
5.5
7
26
VCL3l
VCL4l
∗ 2 Mounting screws (for mounting bracket) are included in bracket part no.
335
Series VCL
Dimensions (N.C.)
Conduit: C
Q
Approx. 280
D
F
Class H coil
Broken line section
C
G1/2
F
Q
E
E
R
Width
across
flats H
(Q)
Approx. 300
R
D
Approx. 300
C
Grommet: G
A
A
H
B
2xP
Port size
B
2xP
Port size
2 x M, thread depth N
L
L
2 x M, thread depth N
K
K
DIN terminal: D
Conduit terminal: T
Cable ø6 to ø12
Q
27.5
F
S
(Q)
F
U
R
C
C
R
(44)
R
25
34
G1/2
B
2xP
Port size
B
(S)
2xP
Port size
2xM
Thread depth N
L
2xM
Thread depth N
A
H
D
L
A
H
D
E
E
G1/2
K
K
N.C. Dimensions
Model
VCL21
VCL31
VCL41
P
(mm)
Grommet: G
Port size
A
1/8
13.5
28
64
31
6.5
12.5
27
14
12.8
M4
4.5 22 (23)
1/4
18
36
67.5 31
8.5
12.5
27
18
12.8
M4
6
22 (23)
1/4, 3/8
22
40
81.5 36.5
11
15
32
20
19
M5
8
24 (25)
1/2
30
50
86
36.5
13.5
15
32
25
23
M5
8
24 (25)
1/4, 3/8
22
45
90
41
11
17
36
22.5
23
M5
8
1/2
30
50
94
41
13.5
17
36
25
23
M5
8
3/4
35
60 102
41
17.5
17
36
30
28.2
M5
8
B
D
E
F
H
K
L
M
N
Note)
Q
Note) ( ) indicates class H.
336
C
Note)
R
Conduit: C
DIN terminal: D
Conduit terminal: T
Q
R
Q
R
S
Q
45 (52)
44
43
58
40.5
46.5
46 (53)
44
44
58
41.5
46.5
56.5 (63.5) 46
54.5
60
52
48.5
59 (66)
57
60
54.5
26 (26.5) 64.5 (71.5) 48
62.5
62
26 (26.5) 66.5 (73.5) 48
64.5
62
26 (26.5) 70 (77)
68
62
46
48
R
S
U
99
43
66
83
99
44
66
86
101
54.5
68
99
48.5
101
57
68 104
60
50.5
103
62.5
70 107
62
50.5
103
64.5
70 111.5
65.5
50.5
103
68
70 119
Direct Operated 2 Port Solenoid Valve
For Oil
Series VCL
How to Order Manifold
VV2C L 2
How to Order Manifold Assembly
02 01
For oil
Thread type
Symbol
Nil
N
F
Series
2
3
4
Class 2
Class 3
Class 4
Thread type
Rc
NPT
G
OUT port size
“∗” is the symbol for
assembly. Add an “∗” in
front of the part numbers
for solenoid valves, etc.,
to be mounted.
VXD
e
1/8 (6A)
01
1/4 (8A)
02
∗ All IN ports are 3/8.
Symbol Base material Seal material
Brass (C37)
Nil
FKM
Stainless steel
H
VX2
Enter together in
order, counting
from station 1 on
the D side.
Port size
Symbol
Material
Enter the mounting valve and option part numbers
under the manifold base part number.
<Ordering Example>
VV2CL2-0501·············· 1 set Manifold part no.
∗ VCL23-5G-2·············· 5 sets Valve part no.
(Stations 1 to 5)
n
U
VXZ
sid
5
VXE
4
3
VXP
2
Stations
02
2 stations
···
···
10
10 stations
ons
1
ti
e
D
sid
Sta
VXR
VXH
VXF
VX3
How to Order Valves (For manifold)
VXA
VC L 2 3
1 G
2
For oil
VCHm
Material and insulation type
Series
2
3
4
Class 2
Class 3
Class 4
Valve type
3
N.C. for manifold
100 VAC
200 VAC
110 VAC
220 VAC
24 VDC
12 VDC
240 VAC
48 VAC
230 VAC
Electrical entry
Grommet
Conduit
Conduit terminal
Conduit terminal with indicator light
DIN terminal
DIN terminal with indicator light
DIN terminal (without connector,
DO with gasket)
G
C
T
TL
D
DL
∗ Class B in AC has a rectifying circuit built-in.
∗∗ Class H is AC only. No rectifying circuit.
∗∗∗Please consult with SMC regarding other voltages.
Symbol Orifice dia. (mmø) Class 2 Class 3 Class 4
2
v
—
—
2
3
v
v
v
3
4
v
v
v
4
5
v
v
v
5
7
—
v
v
7
Manifold Option
VVCW 2 0
Series
2
3
4
JIS Symbol
3A H
Material
Class 2
Class 3
Class 4
LVM
VCB
VCL
VCS
VCW
∗ All class B coils come with surge voltage suppressor.
∗∗ Available types of electrical entry for type H coil are either
G, C or T. (without surge voltage suppressor, light.)
Blanking plate assembly
VQ
VCA
Orifice diameter
Voltage
1
2
3
4
5
6
7
8
J
VDW
Symbol Body material Seal material Coil insulation type
Class B
Nil
Brass (C37)
Class H
D
FKM
Class B
H
Stainless steel
Class H
N
Symbol Plate material Seal material
Stainless steel
FKM
H
This is used by mounting it on the manifold block when a valve is removed for maintenance or
when the mounting of an additional valve is planned, etc.
337
Series VCL
R
T
W
(44)
(Y)
Z
Dimensions (N.C.)
T
25
l =280
l =300
IN port 2 x 3/8∗
∗: Thread type
Plug provided on U side at shipping.
L1
L2
L3
1
Stations
2
(N)
16
3
4
n
5
U side
OUT port n x 1/4∗
n x 1/8∗
∗: Thread type
P=J
(Pitch)
2
H
5.5
16
21
D side
C
B
C
D
G
A
Q
(U)
E
(V)
S
(X)
2.5
H
L Dimension
Model
VV2CL2
VV2CL3
VV2CL4
(mm)
Dimensions
n (stations)
2
3
4
5
6
7
8
9
10
L1
70
105
140
175
210
245
280
315
350
L2
82
117
152
187
222
257
292
327
362
L3
94
129
164
199
234
269
304
339
374
L1
78
117
156
195
234
273
312
351
390
L2
90
129
168
207
246
285
324
363
402
L3
102
141
180
219
258
297
336
375
414
L1
84
126
168
210
252
294
336
378
420
L2
96
138
180
222
264
306
348
390
432
108
150
192
234
276
318
360
402
444
L3
Manifold composition 2 stns. x 1 3 stns. x 1 2 stns. x 2 2 stns. + 3 stns. 3 stns. x 2 2 stns. x 2 + 3 stns. 2 stns. + 3stns. x 2 3 stns. x 3 2 stns. x 2 + 3 stns. x 2
Note) Manifold base is consisted of the junction of 2 and 3 station bases.
Dimensions
(mm)
Electrical entry
Model
A
B
C
D
E
G
H
J
Z
Grommet
Q
Note)
Conduit
Note)
N
X
20
24.5
28
4.5
38
17.3
34.5
56
22 (23)
45.5 (52.5)
44
43.5
46
58
41.5
66
99
VV2CL3
57
25.5
28.5
30
5.5
42
19.3
38.5
66
24 (25)
55
45.5
53
48
60
51
68
101
86.5
VV2CL4
57
25.5
28.5
30
5.5
42
20.8
41.5
74
26 (26.5)
62.5 (69.5)
47.5
60.5
50
62
58.5
70
103
94
338
T
U
V
W
Conduit terminal
49
(62)
S
DIN terminal
VV2CL2
Note) ( ) indicates class H.
R
Y
77
Direct Operated 2 Port Solenoid Valve
For Heated Water
Series VCB
Series VC
How to Order Valves
VX2
VXD
VC B 2 1
1 G
2
02
VXZ
For heated water
Made to order
specifications
VXE
X10
VXP
Oil-free specification
Option
Nil
Series
2
3
4
None
VXR
Foot type bracket
F
∗ Bracket is packed in the same
container as the main body.
Class 2
Class 3
Class 4
VXH
Material and insulation type
Symbol Body material Seal material Coil insulation type
Nil
FKM
CAC407
(BC7)
EPDM
M
Class H
FKM
N
Stainless
steel
EPDM
P
Valve type
N.C.
2
1
N
F
Voltage
Electrical entry
VXA
VDW
VQ
100 VAC
1
200 VAC
2
110 VAC
3
220 VAC
4
240 VAC
7
48 VAC
8
230 VAC
J
∗ Please consult with SMC
regarding other voltages.
G – Grommet
Rc
NPT
G
Nil
VX3
VCHm
Thread type
1
VXF
Port size
01
02
03
04
06
Class 3
—
v
v
v
—
Class 2
v
v
—
—
—
Port size
1/8 (6A)
1/4 (8A)
3/8 (10A)
1/2 (15A)
3/4 (20A)
Symbol
LVM
Class 4
—
v
v
v
v
VCA
VCB
VCL
Orifice size
C – Conduit
Symbol Orifice dia. (mmø) Class 2
2
v
2
3
v
3
4
v
4
5
v
5
7
—
7
10
—
10
Class 3
—
v
v
v
v
v
VCS
Class 4
—
v
v
v
v
v
VCW
∗ Refer to the below table for orifice and port size combinations.
T – Conduit terminal
Orifice diameter and Port Size Combinations
Class
2
3
∗ Available types of electrical entry are either G, C and T.
(Surge voltage suppressor is not equipped.)
4
Orifice dia. (mmø)
Port
size
2
3
4
5
7
1/8 (6A)
V
V
V
V
— —
1/4 (8A)
V
V
V
V
— —
1/4 (8A)
—
V
V
V
V
—
3/8 (10A) — V V
1/2 (15A) — — —
V
V
V
1/4 ( 8A) —
3/8 (10A) —
V
V
V
V
1/2 (15A) — — —
3/4 (20A) — — —
10
— —
V
V
V
—
V
V
V
— —
V
— —
V
329
Series VCB
Standard Specifications
Valve construction
Direct operated poppet
Fluid
Heated water (99°C or less)
Valve specifications
Withstand pressure (MPa)
5.0
Body material
CAC407, Stainless steel
Seal material
FKM, EPDM
Ambient temperature (°C)
–20 to 100
Fluid temperature (°C)
1 to 99
Enclosure
Dusttight, low jetproof (equivalent to IP65)
Environment
Location without corrosive or explosive gases
Valve leakage (cm3/min)
0.1 or less (With water pressure)
Exterior leakage (cm3/min)
0.1 or less (With water pressure)
Mounting orientation
Unrestricted
Coil specifications
Vibration/Impact resistance (m/s2) Note 1)
Rated voltage
30/150 or less
48 VAC, 100 VAC, 110 VAC, 200 VAC, 220 VAC, 230 VAC, 240 VAC (50/60 Hz)
±10% of rated voltage
Allowable voltage fluctuation
Coil insulation type
Class H
Power consumption (W) 50/60 Hz
VCB2: 4.9/4.1, VCB3: 7.7/6.6, VCB4: 10.5/9.3
Apparent power (VA) Inrush
50/60 Hz
Holding
VCB2: 22/19, VCB3: 36/30, VCB4: 45/37
VCB2: 10/8, VCB3: 15/13, VCB4: 19/16
Note1) Vibration resistance ···· Conditions when tested with one sweep of 10 to 250 Hz in the axial direction and at a right angle to the armature, in both energized and deenergized states. No malfunction occurred when tested. (Value at the initial state)
Impact resistance ···· Conditions when tested with a drop tester in the axial direction
and at a right angle to the armature, one time each in energized
and deenergized states. No malfunction occurred when tested.
(Value at the initial state)
Characteristic Specifications
Note 1)
Max. operating
Orifice
Model Class Port size diameter pressure differential
(MPa)
(mmø)
Note 1)
VCB2
VCB3
VCB4
2
3
4
1/8 (6A)
1/4 (8A)
1/4 (8A)
3/8(10A)
1/2(15A)
1/4 (8A)
3/8(10A)
1/2(15A)
3/4(20A)
Max.
operating
pressure
Av x 10-6(m2) Cv converted
(MPa)
Flow characteristics
2
2.0
3.8
0.16
3
0.8
7.9
0.33
4
0.5
12
0.51
5
0.3
16
0.65
3
2.0
4
0.8
13
0.54
5
0.5
19
0.80
7
0.2
33
1.4
10
0.1
50
2.1
3
3.0
4
1.3
14
0.60
5
0.7
20
0.85
7
0.3
33
1.4
8.4
8.4
Mass
(kg)
3.0
1/8 : 0.21
1/4 : 0.24
3.0
1/4 : 0.42
3/8 : 0.40
1/2 : 0.49
3.0
1/4 : 0.58
3/8 : 0.55
1/2 : 0.62
3/4 : 0.78
0.35
0.35
10
2.1
0.12
50
Note 1) Refer to model selection on page 329 regarding port size and orifice diameter combinations.
Note 2) Mass values are for the grommet type.
330
Direct Operated 2 Port Solenoid Valve
For Heated Water
Series VCB
Construction
q
w
VX2
VXD
VXZ
e
VXE
r
VXP
Component Parts
t
y
u
IN
1
2
3
4
5
6
7
VXR
Material
Description
No.
Standard
Clip
Tube assembly
VXH
Stainless steel
—
Stainless steel/Cu
Stainless steel/Ag
Coil assembly
Armature assembly
Option
VXF
Class H
—
Stainless steel/FKM
Stainless steel/EPDM
Seal
Return spring
Body
VX3
FKM
EPDM
Stainless steel
—
CAC407
Stainless steel
VXA
Refer to pages 314 and 315 for solenoid coil replacement and replacement parts.
Dimensions: Bracket
VCHm
VDW
VQ
J
A
1.5
4 x øG
C
LVM
VCA
E
D
B
L
VCB
VCL
VCS
VCW
4 x øH
Valve mounting hole
F
Bracket Mounting Dimensions/Bracket Material: Stainless Steel
(mm)
Valve model
Port size
Bracket part no.
A
B
C
D
E
F
G
H
J
L
VCB2l
1/8, 1/4
VCW20-12-01A
34
40
25
30
12.8
12.8
5
4.5
6
13
VCB3l
1/4, 3/8
VCW30-12-02A
42
52
30
40
19
19
6
5.5
7
19
1/2
VCW30-12-04A
48
56
36
44
23
23
6
5.5
7
23
1/4, 3/8
VCW40-12-02A
42
52
30
40
23
23
6
5.5
7
19
1/2
VCW30-12-04A
48
56
36
44
23
23
6
5.5
7
23
VCW40-12-06A
56
65
44
∗ 2 mounting screws (for mounting bracket) are included in bracket part no.
53
28.2
28.2
6
5.5
7
26
VCB4l
3/4
331
Series VCB
Dimensions
Grommet : G
Conduit: C
F
Approx. 280
C
Width across
flats H
Q
F
C
D
G1/2
E
E
R
Width across
flats H
Q
R
Approx. 300
D
B
A
A
2xP
Port size
B
2xP
Port size
2xM
Thread depth N
L
L
2xM
Thread depth N
K
K
Conduit terminal: T
(Q)
F
R
C
U
25
34
E
G1/2
B
A
H
D
(S)
2xP
Port size
2xM
L
Thread depth N
K
(mm)
Model
VCB21
VCB31
VCB41
332
P
Port size
Electrical entry
A
B
C
D
1/8
13.5
28
64
31
E
F
H
K
L
M
N
Grommet: G
Conduit: C
Conduit terminal: T
Q
R
Q
R
Q
R
S
U
99
50
66
83
99
86
6.5
12.5
27
14
12.8
M4
4.5
22
59
44
50
8.5
1/4
18
36
67.5
31
12.5
27
18
12.8
M4
6
22
62
44
53
53
66
1/4, 3/8
22
40
81.5
36.5
11
15
32
20
19
M5
8
24
76
46
66.5
101
66.5
68
99
1/2
30
50
86
36.5
13.5
15
32
25
23
M5
8
24
80
46
71
101
71
68
104
1/4, 3/8
22
45
90
41
11
17
36
22.5
23
M5
8
26
84
48
74.5
103
74.5
70
107
1/2
30
50
94
41
13.5
17
36
25
23
M5
8
26
88
48
78.5
103
78.5
70
111.5
3/4
35
60
102
41
17.5
17
36
30
28.2
M5
8
26
96
48
86.5
103
86.5
70
119
Direct Operated 2 Port Solenoid Valve
For Steam
Series VCS
Series VC
How to Order Valves (Single Unit)
VX2
VXD
VC S 2 1
1 G
2
02
VXZ
For steam
VXE
Option
None
Foot type bracket
F
∗ Bracket is packed in the same
container as the main body.
Nil
Series
2
3
4
Class 2
Class 3
Class 4
VXP
VXR
Material and insulation type
Symbol Body material Seal material Coil insulation type
Nil
PTFE
Brass (C37)
D
FKM
Class H
R
PTFE
Stainless steel
N
FKM
Valve type
N.C.
2
1
Rc
NPT
G
Nil
N
F
100 VAC
200 VAC
110 VAC
220 VAC
240 VAC
48 VAC
230 VAC
VDW
Port size
01
02
03
04
06
∗Please consult with SMC
regarding other voltages.
VQ
Class 2
v
v
—
—
—
Port size
1/8 ( 6A)
1/4 ( 8A)
3/8 (10A)
1/2 (15A)
3/4 (20A)
Symbol
Class 3
—
v
v
v
—
Class 4
—
v
v
v
v
LVM
VCA
VCB
Orifice diameter
Electrical entry
G – Grommet
C – Conduit
Symbol Orifice dia. (mmø)
2
2
3
3
4
4
5
5
7
7
10
10
Class 2
v
v
v
v
—
—
Class 3
—
v
v
v
v
v
VCL
Class 4
—
v
v
v
v
v
VCS
VCW
∗ Refer to the below table for orifice and port size combinations.
Orifice diameter and Port Size Combinations
T – Conduit terminal
Class Port size
2
3
4
∗ Available types of electrical entry are either G, C and T.
(Surge voltage suppressor, light are not equipped.)
Orifice diameter (mmø)
Note 1)
2
3
4
5
7
1/8 ( 6A) V
1/4 ( 8A) V
1/4 ( 8A) —
V
V
V
— —
V
V
V
— —
V
V
V
V
—
3/8 (10A) —
1/2 (15A) —
1/4 ( 8A) —
V
V
V
V
V
3/8 (10A) —
1/2 (15A) —
3/4 (20A) —
VX3
VCHm
Voltage
1
2
3
4
7
8
J
VXF
VXA
Thread type
1
VXH
10
— —
— —
V
V
V
V
V
—
V
V
V
V
V
— — — — V
— — — — V
Note 1) ø10 is available with seal material FKM only.
339
Series VCS
Standard Specifications
Valve construction
Direct operated poppet
Fluid
Steam (184°C or less)
Valve specifications
Withstand pressure (MPa)
5.0
Body material
Brass (C37), Stainless steel
Seal material
PTFE, FKM
Ambient temperature (°C)
–20 to 100
Fluid temperature (°C)
184 or less (PTFE), 120 or less (FKM)
Enclosure
Dusttight, Low jetproof (IP65)
Environment
Location without corrosive or explosive gases
Valve leakage (cm3/min)
300 or less (PTFE), 1 or less (FKM) measured by air
Exterior leakage (cm3/min)
1 or less with air
Mounting orientation
Unrestricted
Vibration/Impact resistance (m/s2) Note 2)
Coil specifications
Note 1)
Rated voltage
30/150 or less
48 VAC, 100 VAC, 110 VAC, 200 VAC, 220 VAC, 230 VAC, 240 VAC (50/60 Hz)
±10% of rated voltage
Allowable voltage fluctuation
Coil insulation type
Class H
Power consumption (W) 50/60 Hz
Apparent power (VA)
50/60 Hz
VCS2: 4.9/4.1, VCS3: 7.7/6.6, VCS4: 10.5/9.3
Inrush
VCS2: 22/19, VCS3: 36/30, VCS4: 45/37
Holding
VCS2: 10/8, VCS3: 15/13, VCS4: 19/16
Note 1) For low pressure steam at a temperature of 120°C or less, use FKM for the seal material.
Note 2) Vibration resistance ···· Conditions when tested with one sweep of 10 to 250 Hz in the axial direction and at a right angle to the armature, in both energized and deenergized states.
No malfunction occurred when tested. (Value at the initial state)
Impact resistance ········ Conditions when tested with a drop tester in the axial direction and at a
right angle to the armature, one time each in energized and deenergized states.
No malfunction occurred when tested. (Value at the initial state)
Characteristic Specifications
2
Max. operating
pressure
differential
(MPa)
1.0
3
0.8
4
0.5
12
0.51
5
0.3
16
0.65
3
1.0
4
0.8
13
0.54
5
0.5
19
0.80
Note 1)
Note 1)
Model Class Port size
VCS2
VCS3
VCS4
2
3
4
1/8 ( 6A)
1/4 ( 8A)
1/4 ( 8A)
3/8 (10A)
1/2 (15A)
1/4 ( 8A)
3/8 (10A)
1/2 (15A)
3/4 (20A)
Orifice
diameter
(mmø)
Flow characteristics Max. system
pressure
Av x
Cv
(MPa)
-6
2
10 (m ) converted
3.8
0.16
7.9
0.33
8.4
1.0
1/8: 0.21
1/4: 0.24
1.0
1/4: 0.42
3/8: 0.40
1/2: 0.49
1.0
1/4: 0.58
3/8: 0.55
1/2: 0.62
3/4: 0.78
0.35
7
0.2
33
1.4
10
0.1
50
2.1
3
1.0
4
1.0
14
0.60
5
0.7
20
0.85
7
0.3
33
1.4
10
0.12
50
2.1
8.4
Mass
(kg)
0.35
Note 1) Refer to page 339 in model selection regarding port size and orifice diameter combinations.
Note 2) The mass is the value for the grommet type.
340
Direct Operated 2 Port Solenoid Valve
For Steam
Series VCS
Construction
q
w
VX2
VXD
e
VXZ
r
t
y
u
IN
VXE
VXP
Component Parts
Material
Description
No.
Standard
Clip
1
2
3
4
5
6
7
Tube assembly
Stainless steel
—
Stainless steel, Cu
Stainless steel, Ag
Coil assembly
Armature assembly
VXR
Option
Class H
—
Stainless steel, PTFE
Stainless steel, FKM
Seal
Return spring
Body
PTFE
FKM
Stainless steel
—
Brass (C37)
Stainless steel
VXH
VXF
VX3
VXA
Refer to pages 314 and 315 for solenoid coil replacement and replacement parts.
Dimensions: Bracket
VCHm
VDW
A
VQ
J
1.5
4 x øG
C
LVM
VCA
E
D
B
L
VCB
VCL
VCS
VCW
4 x øH
Valve mounting hole
F
Bracket Mounting Dimensions/Bracket Material: Stainless Steel
(mm)
Valve model
Port size
Bracket part no.
A
B
C
D
E
F
G
H
J
L
VCS21
1/8, 1/4
VCW20-12-01A
34
40
25
30
12.8
12.8
5
4.5
6
13
1/4, 3/8
VCW30-12-02A
42
52
30
40
19
19
6
5.5
7
19
1/2
VCW30-12-04A
48
56
36
44
23
23
6
5.5
7
23
1/4, 3/8
VCW40-12-02A
42
52
30
40
23
23
6
5.5
7
19
1/2
VCW30-12-04A
48
56
36
44
23
23
6
5.5
7
23
VCW40-12-06A
56
65
44
∗ 2 mounting screws (for mounting bracket) are included in bracket part no.
53
28.2
28.2
6
5.5
7
26
VCS31
VCS41
3/4
341
Series VCS
Dimensions
Conduit: C
F
Q
F
E
G1/2
E
A
Approx. 280
D
R
Width
across
flats H
Q
C
D
C
Approx. 300
R
Grommet: G
B
2xP
Port size
B
A
H
2xP
Port size
2xM
Thread depth N
2xM
L
L
Thread depth N
K
K
Conduit terminal: T
(Q)
F
R
C
U
25
34
E
G1/2
B
A
H
D
(S)
2xP
Port size
2xM
L
Thread depth N
K
N.C.
(mm)
Electrical entry
Model
VCS21
VCS31
VCS41
342
P
Port size
A
B
C
1/8
13.5
28
64
D
31
E
F
H
K
L
M
N
Grommet: G
Conduit: C
Q
R
Q
R
6.5
12.5
27
14
12.8
M4
4.5
22
59
44
50
8.5
Conduit terminat: T
Q
R
S
U
99
50
66
83
99
86
1/4
18
36
67.5 31
12.5
27
18
12.8
M4
6
22
62
44
53
53
66
1/4, 3/8
22
40
81.5 36.5
11
15
32
20
19
M5
8
24
76
46
66.5
101
66.5
68
99
1/2
30
50
86
36.5
13.5
15
32
25
23
M5
8
24
80
46
71
101
71
68
104
1/4, 3/8
22
45
90
41
11
17
36
22.5
23
M5
8
26
84
48
74.5
103
74.5
70
107
1/2
30
50
94
41
13.5
17
36
25
23
M5
8
26
88
48
78.5
103
78.5
70
111.5
3/4
35
60
102
41
17.5
17
36
30
28.2
M5
8
26
96
48
86.5
103
86.5
70
119
Direct Operated 2 Port Solenoid Valve
For Steam
Series VCS
How to Order Manifold
VV2C S 2
Enter the mounting valve and option part numbers
under the manifold base part number.
<Ordering Example>
VV2CS2-D0501········· 1 set Manifold part no.
∗ VCS23-1G-2··········· 5 sets Valve part no.
(Stations 1 to 5)
“∗” is the symbol for
assembly. Add a “∗”
Enter together in
in front of the part
order, counting
numbers for solefrom station 1 on
noid valves, etc., to
the D side.
be mounted.
de
Thread type
For steam
Symbol
Nil
Series
2
3
4
How to Order Manifold Assembly
D 02 01
N
F
Class 2
Class 3
Class 4
Thread type
Rc
NPT
G
OUT port size
Material
Port size
1/8 (6A)
1/4 (8A)
Symbol
01
02
Symbol Body material Seal material
Brass (C37)
D
FKM
Stainless steel
N
i
n
Us
VX2
VXD
VXZ
5
∗ All IN ports are 3/8.
VXE
4
3
Stations
02
2
2 stations
···
···
10
10 stations
s
e
D
sid
VXP
1
on
tati
S
VXR
VXH
VXF
VX3
How to Order Valves (For manifold)
VC S 2 3
VXA
1 G
2
VCHm
For steam
Symbol Body material Seal material Coil insulation type
PTFE
Nil
Brass (C37)
FKM
D
Class H
PTFE
R
Stainless steel
FKM
N
Series
2
3
4
Class 2
Class 3
Class 4
Symbol Orifice dia. (mmø) Class 2
v
2
2
v
3
3
v
4
4
v
5
5
—
7
7
N.C. for manifold
Voltage
100 VAC
1
200 VAC
2
110 VAC
3
220 VAC
4
240 VAC
7
48 VAC
8
230 VAC
J
∗ Please consult SMC
regarding other voltages.
Class 3 Class 4
—
—
v
v
v
v
v
v
v
v
VCL
VCS
Electrical entry
VCW
G Grommet
C Conduit
T Conduit terminal
∗Available types of electrical entry are either G, C and T.
(Surge voltage suppressor, light are not equipped.)
Blanking plate assembly
JIS symbol
VVCW 2 0 3A K
2
3
4
Material
Class 2
Class 3
Class 4
LVM
VCB
Manifold Option
Series
VQ
VCA
Orifice diameter
Valve type
3
VDW
Material and insulation type
Symbol Plate material Seal material
PTFE
K
Stainless steel
FKM
H
This is used by mounting it on the manifold block when a valve is removed for maintenance or
when the mounting of an additional valve is planned, etc.
343
Series VCS
(Y)
Z
R
T
Dimensions
T
25
IN port 2 x 3/8∗
∗: Thread type
l =300
(N)
2.5
SMC
16
L1
L2
L3
Stations
1
2
3
4
n
5
U side
P=J
N x 1/4∗
N x 1/8∗
∗: Thread type
(pitch)
H
2
H
5.5
16
21
D side
C
C
B
D
G
SMC
A
Q
S
E
(X)
l =280
Plug provided on U side at shipping.
L Dimension
Model
(mm)
Dimensions
VV2CS2
VV2CS3
VV2CS4
n (stations)
2
3
4
5
6
7
8
9
10
L1
70
105
140
175
210
245
280
315
350
L2
82
117
152
187
222
257
292
327
362
L3
94
129
164
199
234
269
304
339
374
L1
78
117
156
195
234
273
312
351
390
L2
90
129
168
207
246
285
324
363
402
L3
102
141
180
219
258
297
336
375
414
L1
84
126
168
210
252
294
336
378
420
L2
96
138
180
222
264
306
348
390
432
L3
108
150
192
234
276
318
360
402
444
Manifold composition
2 stns. x 1 3 stns. x 1 2 stns. x 2 2 stns. + 3 stns. 3 stns. x 2 2 stns. x 2+ 3 stns. 2 stns. + 3 stns x 2 3 stns. x 3 2 stns. x 2 + 3 stns. x 2
Note) Manifold base is consisted of the junction of 2 and 3 station bases.
Dimensions
(mm)
Electrical entry
Model
A
B
VV2CS2
49
VV2CS3
VV2CS4
344
Grommet: G Conduit: C Conduit terminal: T
C
D
E
G
H
J
Z
Q
R
T
N
X
20
24.5
28
4.5
38
17.3
34.5
56
22
50.5
44
41.5
66
99
57
25.5
28.5
30
5.5
42
19.3
38.5
66
24
60
45.5
51
68
101
86.5
57
25.5
28.5
30
5.5
42
20.8
41.5
74
26
68
47.5
58.5
70
103
94
S
Y
77
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project