Introduction................................................................... 3.25 Cables Singlemode............................................................ 3.26 Internal................................................................... 3.34 Duct Grade............................................................. 3.35 Direct Burial............................................................ 3.36 Installation Equipment................................................... 3.37 Blowing Accessories....................................................... 3.40 • 10/06 w w w. a d c k ro n e . c o m 3.23 Blown Fibre Tubes Campus & Backbone Multimode.............................................................. 3.30 102588BE TrueNet® Structured Cabling Campus & Backbone Blown Fibre 10/06 • 102588BE Blown Fibre TrueNet® Structured Cabling Campus & Backbone 3.24 w w w. a d c k ro n e . c o m Campus & Backbone TrueNet® Blown Fibre Introduction The TrueNet Blown Fibre system from ADC KRONE provides a simple solution to manage evolving network demands without the need for high initial capital expenditure or extensive network planning. Blown Fibre enables optical networks to adapt to changing business requirements. Building your network using the TrueNet Blown Fibre system could realise the following benefits: Simplified Planning • Network is built according to today’s needs • Fibre count can be increased as demand grows Speed of Customer Connections • Equivalent performance for first connections, significantly reduced timescales and costs for subsequent connections • Existing tube routes can be interrupted at any place, allowing rapid network upgrades The flexibility offered by a blown fibre solution can substantially minimise network bill costs. Given the uncertainty of trends in technology, demand growth, people movement and financial confidence, Blown Fibre provides a flexible, low total life cost and complete solution. 10/06 w w w. a d c k ro n e . c o m 3.25 Blown Fibre Increased Flexibility • Future proof network build • Networks are easily upgraded, branched or extended, giving maximum flexibility and uninterrupted fibre blowing right to the destination • Simplified emergency restoration • Latest and emerging fibre technologies can be deployed Campus & Backbone Cost Effective • Pay as you grow – install empty tubes and only pay for fibre as and when required spreading capital investment overtime • Reduced splicing – minimises branching and splicing of traditional networks thus reducing engineering costs • Deployment of fibres is related to actual requirement • Elimination of unlit fibre • 102588BE TrueNet® Structured Cabling The TrueNet solution allows optical fibres to be deployed on demand from one point of a network to another (internal or external) using compressed air to blow optical fibre into pre-installed tubes. Campus & Backbone TrueNet® Blown Fibre 102588BE • 10/06 Blown Fibre Campus & Backbone TrueNet® Structured Cabling Blown Fibre Unit Singlemode 3.26 ADC KRONE’s optical fibre units are specifically engineered for blown fibre applications. The fibres are contained in a soft inner acrylate layer which cushions the fibres and an outer harder layer which protects the fibres from damage. Glass microspheres, added to the outer layer during manufacturing, provide a low friction layer that assists in improving blowing distances, which are typically in excess of 1000m. The blown fibre units are identified by a colour coded outer layer. Features • Colour coded outer layer identifies the grade of fibre in the unit • Blowing distances up to 1000m (750m for 12 core) • Fibre units are manufactured to British Telecom specifications • Fibres already installed can be removed and replaced with a higher fibre count, ensuring future capacity of the installation • Once removed, the fibres can be re-used at another site, helping to keep the cost of installation down • Fibres can be deployed from an external location to the internal presentation point, removing the need to splice at the building entry point w w w. a d c k ro n e . c o m Campus & Backbone TrueNet® Blown Fibre Blown Fibre Unit OS1 Singlemode (9/125µm) Catalogue Number 500m 7032 1 401-00 1000m 7032 1 400-01 2000m 7032 1 400-02 6000m 7032 1 400-03 Blown Fibre, Singlemode, 4 Fibre Cores 500m 7032 1 401-01 1000m 7032 1 400-04 2000m 7032 1 400-05 6000m 7032 1 400-06 Blown Fibre, Singlemode, 8 Fibre Cores 500m 7032 1 401-02 1000m 7032 1 400-07 2000m 7032 1 400-08 4000m 7032 1 400-09 Blown Fibre, Singlemode, 12 Fibre Cores 500m 7032 1 401-12 1000m 7032 1 401-13 1500m 7032 1 401-03 2000m 7032 1 401-14 4000m 7032 1 401-15 • 10/06 w w w. a d c k ro n e . c o m 3.27 Blown Fibre Description Blown Fibre, Singlemode, 2 Fibre Cores Campus & Backbone 102588BE TrueNet® Structured Cabling Ordering Information Campus & Backbone TrueNet® Blown Fibre Blown Fibre Unit Singlemode Optical properties Value Units Attenuation coefficient 1310nm ≤ 0.38 dB/km 1550nm ≤ 0.26 dB/km Mode field diameter Petermann II 9.2 ± 0.4 µm Cut-off wavelength (cabled) λcc ≤1260 nm Dispersion 1285 - 1330nm ≤ 3.5 ps/nm.km 1550nm ≤ 18 ps/nm.km Zero dispersion wavelength λ0 1300 - 1324 nm Slope ≤ 0.092 ps/nm2.km 125 ± 1 µm Core to cladding concentricity error ≤ 0.7 µm Reference surface non-circularity ≤ 1.5 % Coating diameter (coloured) 245 ± 10 µm ≥ 1.0 % Geometrical properties Reference surface diameter Physical properties • 102588BE Proof test level 10/06 Blown Fibre Campus & Backbone TrueNet® Structured Cabling Technical Data 3.28 w w w. a d c k ro n e . c o m Campus & Backbone TrueNet® Blown Fibre Blown Fibre Unit Singlemode Specifications 1.02± 0.06 Sheath colour Packaging Units 1.4 1.38 mm Grey 0.8 ≤2 Blowing distance (typical) Fibre colours 12 Yellow Weight Breakout (typical) 8 ≤3 1.5 1.66 g/m ≤5 ≤1 minutes 1000 Blue, orange Blue, orange, green, red 750 Blue, orange, green, red, violet, grey, yellow, brown Fibre rosette into pan metres Blue, orange, green, red, violet, grey, yellow, black, white, pink, turquoise, brown Fibre on reel 10/06 • 102588BE TrueNet® Structured Cabling Diameter 4 w w w. a d c k ro n e . c o m 3.29 Blown Fibre 2 Campus & Backbone Number of fibres Campus & Backbone TrueNet® Blown Fibre 102588BE • 10/06 Blown Fibre Campus & Backbone TrueNet® Structured Cabling Blown Fibre Unit Multimode 3.30 ADC KRONE’s optical fibre units are specifically engineered for blown fibre applications. The fibres are contained in a soft inner acrylate layer which cushions the fibres and an outer harder layer which protects the fibres from damage. Glass microspheres, added to the outer layer during manufacturing, provide a low friction layer that assists in improving blowing distances, which are typically in excess of 1000m. The blown fibre units are identified by a colour coded outer layer. Features • Colour coded outer layer identifies the grade of fibre in the unit • Blowing distances up to 1000m (750m for 12 core) • Fibre units are manufactured to British Telecom specifications • Fibres already installed can be removed and replaced with a higher fibre count, ensuring future capacity of the installation • Once removed, the fibres can be re-used at another site, helping to keep the cost of installation down • Fibres can be deployed from an external location to the internal presentation point, removing the need to splice at the building entry point w w w. a d c k ro n e . c o m Campus & Backbone TrueNet® Blown Fibre Blown Fibre Unit OM1 Multimode (62.5/125um) 10/06 • 102588BE Description Blown Fibre, Multimode 62.5/125um, 2 Fibre Cores 500m 7032 1 401-06 1000m 7032 1 400-20 2000m 7032 1 400-21 4000m 7032 1 400-22 6000m 7032 1 400-23 Blown Fibre, Multimode 62.5/125um, 4 Fibre Cores 500m 7032 1 400-25 1000m 7032 1 400-26 2000m 7032 1 400-27 4000m 7032 1 400-28 Blown Fibre, Multimode 62.5/125um, 8 Fibre Cores 500m 7032 1 400-29 1000m 7032 1 400-30 2000m 7032 1 400-31 4000m 7032 1 400-32 Catalogue Number Blown Fibre Unit OM2 Multimode (50/125um) Ordering Information Description Blown Fibre, Multimode 50/125um, 2 Fibre Cores 500m 7032 1 401-04 1000m 7032 1 400-10 2000m 7032 1 400-11 4000m 7032 1 400-12 Blown Fibre, Multimode 50/125um, 4 Fibre Cores 500m 7032 1 401-05 1000m 7032 1 400-13 2000m 7032 1 400-14 4000m 7032 1 400-15 Blown Fibre, Multimode 50/125um, 8 Fibre Cores 500m 7032 1 400-16 1000m 7032 1 400-17 2000m 7032 1 400-18 4000m 7032 1 400-19 w w w. a d c k ro n e . c o m Catalogue Number 3.31 Blown Fibre Campus & Backbone TrueNet® Structured Cabling Ordering Information Campus & Backbone TrueNet® Blown Fibre Blown Fibre Unit OM3 Multimode (62.5/125um) Description 2F OM3 Multimode PANS Catalogue Number 500M 1000M 7032 1 406-01 7032 1 406-02 2000M 7032 1 406-03 4F OM3 Multimode PANS 500M 7032 1 406-05 1000M 7032 1 406-06 2000M 7032 1 406-07 8F OM3 Multimode PANS 500M 7032 1 406-09 1000M 7032 1 406-10 2000M 7032 1 406-11 12F OM3 Multimode PANS 1000M 7032 1 406-14 2000M 7032 1 406-15 Blown Fibre Unit OM3e Multimode (62.5/125um) Ordering Information Description Catalogue Number 2F OM3e Multimode PANS 500M 7032 1 407-01 1000M 7032 1 407-02 2000M 7032 1 407-03 4F OM3e Multimode PANS 500M 7032 1 407-05 1000M 7032 1 407-06 2000M 7032 1 407-07 8F OM3e Multimode PANS 500M 7032 1 407-09 1000M 7032 1 407-10 • 102588BE 2000M 7032 1 407-11 10/06 Blown Fibre Campus & Backbone TrueNet® Structured Cabling Ordering Information 3.32 12F OM3e Multimode PANS 1000M 7032 1 407-14 2000M 7032 1 407-15 w w w. a d c k ro n e . c o m Campus & Backbone TrueNet® Blown Fibre 10/06 • 102588BE Optical Properties Value Units Attenuation coefficient 850 nm 1300 nm OM1 OM2, 3, 3e OM1 OM2, 3, 3e ≤ 3.5 ≤ 2.6 ≤ 1.0 ≤ 1.2 dB/km dB/km dB/km dB/km Modal bandwidth 850 nm 1300 nm OM1 OM2 OM3 OM3e OM1 OM2 OM3 OM3e ≥ 200 ≥ 500 ≥ 1500 ≥ 3500 ≥ 600 ≥ 800 ≥ 500 ≥ 500 MHz.km MHz.km MHz.km MHz.km MHz.km MHz.km MHz.km MHz.km Effective modal bandwidth 850 nm OM3 OM3e ≥ 2000 ≥ 4700 MHz.km MHz.km 10Gbe transmission distance 850 nm OM3 OM3e 300 550 m m 125 ± 2 62.5 ± 3 50 ± 3 % ≤ 2 250 ± 15 µm µm µm Cladding diameter Core diameter OM1 OM2, 3, 3e Core to cladding concentricity error ≤ 3 Cladding non-circularity Coating diameter (coloured) % µm Physical Properties Proof test level ≥ 1 % 12 Units Specifications Number of fibres 2 Diameter Sheath colour 4 8 1.02± 0.06 1.4 OM1 = red, OM2/3 = blue, OM3e = turquoise mm Grey Weight 0.8 0.9 1.5 g/m Breakout (typical) ≤2 ≤3 ≤5 minutes Blowing distance (typical) Fibre colours Packaging 1000 Blue, orange Blue, orange, green, red 750 Blue, orange, green, red, violet, grey, yellow, brown metres Blue, orange, green, red, violet, grey, yellow, black, white, pink, turquoise, brown Fibre rosette into pan w w w. a d c k ro n e . c o m 3.33 Blown Fibre Geometrical Properties Campus & Backbone TrueNet® Structured Cabling Blown Fibre Unit Multimode Campus & Backbone TrueNet® Blown Fibre TrueNet® Blown Fibre Tubes (Internal) HDPE (High Density Polyethylene) low friction tubes for blown fibre installations in-building applications. • 5mm O/D, one tube accommodates up to a 12 fibre unit • LSZH indoor version with flame retardant properties • Supplied on wooden drums Ordering Information Description ssembly Nominal A Type O.D. (mm) Rip Cord Quantity Catalogue Number Min. Bend Max Nominal Metres Radius (mm) Tensile (N) Weight (g/m) 1 Way 5.0 - 150 80 14 500 7032 1 400-43 2 Way 7.2 x 12.2 1 150 390 74 500 7032 1 400-44 4 Way 12.2 1 250 600 118 500 7032 1 400-45 7 Way 17.2 1 350 880 175 500 7032 1 400-46 12 Way 22.5 2 450 1500 267 500 7032 1 401-17 19 Way 27.2 2 550 2200 387 500 7032 1 400-47 Crush Performance Tested in accordance with IEC 60794-1-2 method E3. After a maintained load of 400N for one minute there shall be no deformation of primary tubes greater than 0.5mm. • 102588BE • Low friction internal coating for maximum fibre blowing distance 10/06 Blown Fibre Campus & Backbone TrueNet® Structured Cabling Features 3.34 w w w. a d c k ro n e . c o m Campus & Backbone TrueNet® Blown Fibre Tube Cable – External Blown Fibre Tubes (Duct Grade/Direct Install) Features • Rapid, dedicated customer connections using proven mechanical protection of HDPE • Low friction internal coating for maximum fibre blowing distance • Each tube accommodates one blown fibre unit (up to 12 fibres in a unit) • External tube cables available in 1, 2, 4, 7, and 19 way assemblies • Cable construction – Direct Install (duct grade), with aluminium moisture barrier Description ssembly Nominal A Type O.D. (mm) Catalogue Number Min. Bend Max. Tensile Nominal Crush Metres Radius Strength (N) Weight (g/m) Rating (kN) 1 Way 9.4 12 x D 1W (490) 49 1 500 7032 1 400-33 2 Way 8.8 x 13.8 12 x D 1W (780) 78 1 500 7032 1 400-34 4 Way 16.5 12 x D 1W (1160) 116 1 500 7032 1 400-35 7 Way 19.4 12 x D 1W (1590) 159 1 500 7032 1 400-36 19 Way 28.8 12 x D 1W (3230) 323 1 1000 7032 1 400-37 10/06 w w w. a d c k ro n e . c o m 3.35 Blown Fibre Ordering Information Campus & Backbone • 5mm tube construction • 102588BE TrueNet® Structured Cabling The external tube cables are offered with a HDPE (High Density Polyethelene) outer sheath and a variable number of HDPE low friction tubes. Campus & Backbone TrueNet® Blown Fibre Tube Cable – External Blown Fibre Tubes (Direct Bury Cable) Features • Rapid, dedicated customer connections using proven mechanical protection of HDPE (High Density Polyethylene) • Low friction internal coating for maximum fibre blowing distance • Each tube accommodates one blown fibre unit (up to 12 fibres in a unit) • External tube cables available in 2, 4, 7 and 12 way assemblies • Cable construction – direct bury with aluminium moisture barrier • 5mm tube construction Ordering Information Description ssembly Nominal A Type O.D. (mm) Catalogue Number Min. Bend Max. Tensile Nominal Crush Metres Radius Strength (N) Weight (g/m) Rating (kN) 2 Way 13.2 x 18.2 12 x D 1W (1420) 142 2 500 7032 1 400-49 4 Way 22.3 12 x D 1W (2040) 204 2 500 7032 1 400-50 7 Way 23.3 12 x D 1W (2780) 278 2 500 7032 1 400-51 12 Way 29.5 12 x D 1W (4790) 479 2 1000 7032 1 401-18 • 102588BE The assembly of 5mm tubes is surrounded by an aluminium moisture barrier and two polyethelene sheath layers for improved physical robustness. 10/06 Blown Fibre Campus & Backbone TrueNet® Structured Cabling The direct bury cable is a heavier construction than the direct install. This cable type lies flatter in trenches, has increased crush rating and has more resistance to localised bending. 3.36 w w w. a d c k ro n e . c o m Campus & Backbone TrueNet® Blown Fibre Installation Equipment Blowing Head The installation speed, which can be controlled by the pushing system, is limited to 40m/min. The maximum installation length can be influenced by the tube path geometry. Ordering Information Description Blown Fibre Blowing Head 2A (MkII) Catalogue Number 7032 1 400-53 12 fibres Range of blown tube diameters 3-12 mm Input drive voltage 24 VDC Pushing force 0-25 N Pressure exerted on fibre 20-100 N Fibre installation rate 0-40 m/min Rated pressure intake 2-10 bar Rated airflow (3-6mm tubes) (8-12mm tubes) Approx. 200 ltrs/min Approx. 500 ltrs/min Dimensions lxwxh Weight 240 x 150 x 190 (mm) 5.5 kg Each blowing head is supplied with: • A case for the apparatus, tools, adaptors and consumption items (joints, lubricant, etc.) • One tube adaptor • One cable adaptor • • Air connector 1/4” and stop valve • One speed and distance counter • One manual for operation and maintenance • One list of spare parts • One spring balance for calibrating the max pulling/pushing force w w w. a d c k ro n e . c o m 3.37 Blown Fibre Maximum fibre size Campus & Backbone Technical Data 10/06 102588BE TrueNet® Structured Cabling The Blowing Head is designed for the installation of Enhanced Performance Fibre Units (EPFU) in tubes by the push-pull method. Here, the cable is pushed by a system of drive and pressure rollers and pulled by a shuttle attached at the cable head. Campus & Backbone TrueNet® Blown Fibre Installation Equipment Blown Fibre Electric Compressor Both models (240v & 110v) feature quiet running, electrically driven rotary vane compressor units. These produce 100 ltrs/min of pulse free treated compressed air at a working pressure of 10 bar. Together with their portability this makes them the ideal source of air for internal building optical fibre installations. An air cooled aftercooler, reduces compressed air temperature to within 2ºC of ambient and a 3-stage filtration system provides technically oil-free air. These units are available with a 24VDC outlet socket for supplying the blowing head. Ordering Information Description Blown Fibre Electric Compressor (110V) Blown Fibre Electric Compressor (240V) Catalogue Number 7032 1 405-00 7032 1 405-01 Voltage Level 10 60dB(A) at 1m 240v-1ph50Hz 10 60dB(A) at 1m 110v-1ph50Hz Width (mm) Height (mm) Weight (kg) Output (ltrs/min) Pressure (bar) 240V 900 450 700 63 100 110V 900 450 700 63 100 102588BE Length (mm) • 3.38 Noise Model 10/06 Blown Fibre Campus & Backbone TrueNet® Structured Cabling The Blown Fibre Compressors are designed to deliver clean dry air for installing optical fibre using the blown fibre technique. w w w. a d c k ro n e . c o m Campus & Backbone TrueNet® Blown Fibre Installation Equipment Blown Fibre Petrol Compressor The unit incorporates a 12VDC air cooled aftercooler reducing the compressed air temperature to within 2ºC of ambient. A 3-stage filtration system provides technically oil-free air. The unit is available with a 24VDC-outlet socket for supplying the blowing head. Ordering Information Length (mm) Width (mm) Height (mm) Output (ltrs/min) Pressure (bar) Weight (kg) 900 500 750 200 10 85 • 10/06 w w w. a d c k ro n e . c o m 3.39 Blown Fibre Catalogue Number 7032 1 400-54 Campus & Backbone Description Blown Fibre Petrol Compressor 102588BE TrueNet® Structured Cabling The blown fibre compressor is a portable, petrol engine driven rotary vane compressor unit. Producing 120 ltrs/min of pulse free treated compressed air at a working pressure of 10 bar, it provides the ideal source for field installation of fibre optic cable. Campus & Backbone TrueNet® Blowing Accessories The Gas Seal Unit is used in business or residential premises. This is a wall mounted unit that is positioned internally at the cable entry point. Incoming external tubing is converted to internal distribution tubing using gas sealing connectors. These connectors are used to seal both populated (with blown fibre unit) and unpopulated tubing. The gas seal unit is used for internally fed cable or with a customer lead-in for cables entering through the fabric of the wall. Features • Compact, low profile, wall mounted unit used in business or residential premises • Removable cover for easy access • Unit manufactured from fire resistant material to UL94-V0 • Kit supplied with components to mount the unit to a wall and secure external cable • Gas sealing connectors used to provide connection of external and internal tubing. Connectors provide gas tight seal for populated (with blown fibre unit) and unpopulated tubes. Gas seal connectors are supplied separately • Gas tight sealing caps used to terminate unused external cable tubes. Gas sealing caps are supplied separately • Accommodates up to one 12 tube external blown fibre cable and internal blown fibre cables, in any combination up to a 12 tube cable • For internally fed cables, a quick set resin (supplied) is used to seal the cable interstices from the ingress of water or gas • For external cables fed via the wall fabric, an interface to an internal customer lead-in is provided • Remote toning point is provided for connection to metallic moisture barrier of the external cable 102588BE Kit shipped with: • Ordering Information • Sealing resin Description Catalogue Number Blown Fibre Gas Seal Unit 7032 1 401-19 • Base and cover • Wall fixings • Toning adaptor 10/06 Blown Fibre Campus & Backbone TrueNet® Structured Cabling TrueNet® Blown Fibre Gas Seal Unit 3.40 w w w. a d c k ro n e . c o m Campus & Backbone TrueNet® Blowing Accessories TrueNet® Blown Fibre Gas Seal Unit Technical Data External cable Maximum cable diameter Dimensions (mm) Operating temperature Material Colour Flammability rating One 12 tube cable 25mm (w) 96 x (d) 60 x (h) 210 -20°C to + 50°C (5 to 95% relative humidity) FR ABS Light grey UL94-V0 Testing Dry heat Damp heat Change of temperature BS EN 60068-2-2 Test Bb IEC 68-2-3 IEC 68-2-14 Specifications Packed Weight (kg): 0.7 EXTERNAL CABLE FEED To Splice Point/s Internal Cable Internal Tube Gas Blocking Connector (not supplied) Gas Blocking Connector (not supplied) Wall Fabric Blown Fibre Gas Seal Unit Gas Seal Unit External Cable Internal Lead-In External Lead-In CUSTOMER PREMISES CUSTOMER PREMISES External Tube 10/06 Cable Supply Duct External Cable Duct The Gas Seal Unit is supplied with wall fixings, wall fixing template, toning connector and sealing resin NOTE: Gas Seal Connectors and Tube Sealing Caps are not supplied w w w. a d c k ro n e . c o m 3.41 Blown Fibre EXTERNAL CABLE FEED Campus & Backbone Application Information • 102588BE TrueNet® Structured Cabling Maximum capacity Campus & Backbone Blowing Accessories TrueNet® Blown Fibre Customer Lead-in Units This product can be used with blown fibre tubing or conventional cable. Features • Compact internal and external mounted units used in business or residential premises • Removable cover for easy access • External unit manufactured from UV resistant material. Internal unit manufactured from fire resistant material to UL94-V0 • Kit supplied with all components necessary to feed external cable elements into the customer premises from an external wall face • Elements are protected through the cavity using a 32mm diameter conduit which interfaces with the internal and external Customer Lead-in units • The external unit is sealed using a quick set resin. This ensures the external cable interstices are sealed against the ingress of water or gas into the customer premises • A remote toning point is provided within the external unit for connection to the metallic moisture barrier of the external cable • All cable elements are positively managed to 50mm minimum bend radius • Internal unit interfaces with a Blown Fibre Gas Seal Unit Ordering Information Description Blown Fibre Customer Lead-in Units Catalogue Number 7032 1 400-85 • 102588BE • Up to 7 x 5mm tubes can be accommodated 10/06 Blown Fibre Campus & Backbone TrueNet® Structured Cabling The Customer Lead-in Unit enables external cable to be passed through the building fabric from an outside wall and is used in business or residential premises. The Customer Lead-in comprises two separate units mounted either side of the wall and connected by a length of conduit. 3.42 The Customer Lead-in consists of one internal unit and one external unit and is supplied with wall fixings, fixing templates, conduit, sealing resin and a toning connector. w w w. a d c k ro n e . c o m Campus & Backbone Blowing Accessories TrueNet® Blown Fibre Customer Lead-in Units Technical Data Maximum cable diameter (mm) Required space envelope (mm) Operating temperature Bend radius (mm) Material Flammability rating 30 (w) 80 x (d) 60 x (h) 140 -20°C to + 50°C (5 to 95% relative humidity) 50 FR ABS UL94-V0 Colour External unit Internal unit Dark grey Light grey Testing Dry heat Damp heat Change of temperature BS EN 60068-2-2 Test Bb IEC 68-2-3 IEC 68-2-14 Packing Dimensions (mm): Packed Weight (kg): Net weight (kg): (w) 500 x (d) 150 x (h) 95 1.04 0.96 Application Information CONVENTIONAL LOOSE TUBE / BUNDLE APPLICATION BLOWN FIBRE TUBING APPLICATION Internal Cable Internal Tube Gas Blocking Connector Wall Fabric Wall Fabric Protective Trunking Gas Seal Unit Internal Lead-In External Lead-In Internal Lead-In External Lead-In 10/06 • 102588BE Internal Splice Point CUSTOMER PREMISES External Optical Cable CUSTOMER PREMISES External Tube Cable Duct Cable Duct w w w. a d c k ro n e . c o m 3.43 Blown Fibre Specifications Campus & Backbone TrueNet® Structured Cabling Maximum capacity Campus & Backbone TrueNet® Blowing Accessories Features • Reconfigurable internal unit to house blown fibre tube connections • Suitable for both internal to internal connections as well as external to internal connections (with the use of gas seal tube connectors) • Accepts up to a 19 way duct at each entry point • Up to 4 ports, reconfigurable dependent upon the application • Can be used as: – a straight through internal connection point – an internal branching point – an external to internal gas sealing unit • Compact and simple to install • Tubes can be positively managed inside the unit so as not to exceed minimum bend radius • Glands are included to ensure an effective fit of units routed through the manifolds Ordering Information Description Catalogue Number Internal Tube Distribution Unit 7032 1 401-50 Kit shipped with: • Base and cover • Wall fixings • Toning adaptor • Sealing resin • 102588BE The Internal Tube Distribution Unit (Internal TDU) has been designed to allow maximum flexibility within building applications. The Internal TDU accepts a range of indoor tube assemblies up to 19 tube capacity. The units allow individual tube breakout, re-routing or gas / water sealing. The tubes are positively managed to prevent excessive tube bending. 10/06 Blown Fibre Campus & Backbone TrueNet® Structured Cabling TrueNet® Internal Tube Distribution Unit 3.44 w w w. a d c k ro n e . c o m Campus & Backbone TrueNet® Blowing Accessories TrueNet® Internal Distribution Unit Technical Data Kit includes back plate, cover, bend radius managers (4), manifolds (8 halves), manifold glands (4), blanking plates (3), screws (4) and a label insert. All components except screws, inserts and cable glands are manufactured from ABS, UL94, V0. Inserts manufactured from brass, lid screws and earthing point stand-off manufactured from zinc plated steel. Cable glands are manufactured from flame retardant Multibase G75A 11 FR Z0481 and have circular cut out grooves to make fitting of tube bundles – up to 19 way rated UL94 V0 at 1.6mm. All plastic parts to Pantone Cool 3C (equivalent to BT Grey – 3P) glands – grey. Specifications The unit has the following overall dimensions: 520 x 280 x 70mm Individual external sizes as follows – Length 320 mm Width 180 mm Depth 70 mm Manifolds: Length 105mm Width variable – max 64mm, min 44mm Depth variable – max 64mm, min 44mm • 10/06 w w w. a d c k ro n e . c o m 3.45 Blown Fibre Campus & Backbone Box: 102588BE TrueNet® Structured Cabling Complete installation instructions are provided with each unit. Campus & Backbone TrueNet® Blowing Accessories Tube Connector 102588BE • Ordering Information Description Blown Fibre Tube Connector 3.46 Catalogue Number 7032 1 400-76 End Cap Used for terminating unused blown fibre tubing within external plant. Ordering Information Description Blown Fibre End Cap Catalogue Number 7032 1 400-72 Water Blocking Connector Used for water blocking blown fibre tubing entering underground external plant. A simple push fit device provides a water tight seal for tubes (unpopulated) and tubes with installed blown fibre units (populated). For populated tubing this device is fitted after fibre units have been installed. Ordering Information Description Blown Fibre Water Blocking Connector 10/06 Blown Fibre Campus & Backbone TrueNet® Structured Cabling Used for simple push fit connection of 5mm to 5mm blown fibre tubing. Can be used in external plant and with internal tubing of customer premises plant where gas sealing is not required. w w w. a d c k ro n e . c o m Catalogue Number 7032 1 400-77 Campus & Backbone TrueNet® Blowing Accessories Gas Seal Connector Ordering Information Description Blown Fibre Gas Seal Connector Catalogue Number 7032 1 222-00 Tube Sealing Cap Description Blown Fibre Tube Sealing Cap Catalogue Number 7032 1 223-00 Reducer Connector Used for simple push fit connection of different sized blown fibre tubes, e.g. 8mm to 5mm. Can be used in external plant and with internal blown fibre tubing of customer premises plant where gas sealing is not required. Ordering Information Description Blown Fibre Reducer Connector Catalogue Number 7032 1 400-73 w w w. a d c k ro n e . c o m 3.47 Blown Fibre Ordering Information Campus & Backbone Used for sealing tubing entering a customer premises. This cap is used with customer premises plant and provides a gas tight seal to unpopulated tubes. 10/06 • 102588BE TrueNet® Structured Cabling Used for gas sealing blown fibre tubing entering a customers premises. The connector is used with customer premise plant and provides the interface between external and internal tubing. The connector simply push fits over the tube providing a gas tight seal for tubes (unpopulated) and tubes with installed fibre (populated). The device allows fibre to be ‘blown through’ into the customer premises. A sealing device is activated externally to seal the tube/unit. Campus & Backbone TrueNet® Blown Fibre Installation Equipment Valve and Moisture Trap Used for controlling the flow of compressed air to the blowing head to enable safe installation of the fibre into the blown fibre tube. 3.48 Catalogue Number 7032 1 501-00 Pan Guide Located on top of the EPFU (Enhanced Performance Fibre Unit) pan during installation, it is used to guide the fibre from the pan to the blowing head. Ordering Information Description Blown Fibre Pan Guide Catalogue Number 7032 1 503-00 Flow Meter Kit Contains a number of connectors that monitor and control the flow of compressed air through a tube link. Ordering Information Description Blown Fibre Flow Meter Kit • 102588BE Description Blown Fibre Valve and Moisture Trap 10/06 Blown Fibre Campus & Backbone TrueNet® Structured Cabling Ordering Information w w w. a d c k ro n e . c o m Catalogue Number 7032 1 502-00 Campus & Backbone TrueNet® Blown Fibre Installation Equipment Tube Integrity and Length Tester (TILT) Ordering Information Description Blown Fibre Tube Integrity and Length Tester Catalogue Number 7032 1 227-00 Blowing Beads Description Blown Fibre Blowing Beads Catalogue Number 7032 1 400-58 Blowing Head Seals For use with Blowing Head when deploying 8 or 12 Blown Fibre Units Ordering Information Description Blown Fibre Blowing Head Seals Catalogue Number 7032 1 508-00 10/06 w w w. a d c k ro n e . c o m 3.49 Blown Fibre Ordering Information Campus & Backbone A blowing bead is fixed to the end of the blown fibre unit before blowing commences. The bead helps the guidance of the blown fibre unit through the blown fibre tube particularly at bends. The beads also minimise the risk of snagging at connector locations. • 102588BE TrueNet® Structured Cabling The Tube Integrity and Length Tester is used to ensure that there are no air leaks in a blow length before installation (Tube and Connector). The full section length can then be measured to ensure an adequate length of fibre unit is available to blow. Campus & Backbone TrueNet® Blowing Accessories Close Down Assembly Ordering Information • 102588BE Description Blown Fibre Close Down Assembly 10/06 Blown Fibre Campus & Backbone TrueNet® Structured Cabling These assemblies, comprising a piece of tube with a connector at either end, are used to protect the area between two lengths of tube following a centre blow. 3.50 w w w. a d c k ro n e . c o m Catalogue Number 7032 1 228-00
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement