19" LCD Monitor

Optional LCD Panel Protector

This protector fits easily between the LCD screen and bezel, has a light transmission rate of more than 90%, and includes both an anti-glare coating side to reduce light reflection and a glossy side for crisper, more vibrant images.

What is Paper Mode?

Simply put, it is a mode which adjusts the brightness, contrast ratio, and color temperature of a monitor to simulate those of printed paper. Over the course of a work day PC users must constantly adjust to the difference between how monitors and paper appear. This overworks the muscles of the eyes and is thought to be a source of eye fatigue and stress. Paper mode was developed to alleviate the eye fatigue and stress that PC users feel.

Comparison between paper, EIZO square monitors, and Paper Mode

Brightness

Contrast Ratio

Newspaper

55 % reflection rate, 88 cd/m 2

*

6.2:1

Recycled Copy

Paper

70 % reflection rate, 112 cd/m 2

*

10.7:1

EIZO Square

Monitors

267 cd/m

2

1167:1 †

Paper Mode

50 - 70 % reflection rate

About 30:1

Color

Temperature

3,477 K 3,828 K

* Measured at an ambient brightness of 500 lx. brightness of FlexScan square monitors .

6500 K

(when shipped)

4,000 – 5,000 K

† Average maximum

Color Temperature, Brightness and the

Effect on Blue Light

In the visible light spectrum, blue light has wavelengths adjacent to ultraviolet light. Compared to the factory preset setting of 6,500 K of typical LCD monitors, Paper Mode is closer to the spectral distribution with long reddish wavelengths so it reduces the amount of blue light, a cause of eye fatigue.

Ultraviolet Light

Blue Light

400 - 500 nm

Visible Light Infrared Light

The combination of Paper Mode and the Auto EcoView brightness adjustment function reduces blue light even more. In a monitor with an LED backlight where Paper

Mode and Auto EcoView were used, the blue light was measured and found to have only 1/6 th factory setting.

the intensity of the

Intensity

(W/(sr m 2 nm))

1.2 E - 02

1.0 E - 02

8.0 E - 03

6.0 E - 03

4.0 E - 03

2.0 E - 03

0.0 E - 00

380

Initial measurement of sample unit: 350 cd/m 2 , 6,500 - 7,000 K

When using Auto EcoView and Paper Mode: 120 cd/m 2 , 5,000 K

430 480

Blue Light

530

Blue light reduced to 1/6

580 630 680 th

730

Wavelength (nm)

S P E C I F I C A T I O N S

Cabinet Colors

Panel Type

Backlight

Size

Native Resolution

Display Size (H x V)

Pixel Pitch

Display Colors

Viewing Angles (H / V, typical)

Brightness (typical)

Contrast Ratio (typical)

Response Time (typical)

Video Signals

Digital Scanning Frequency (H / V)

Analog Scanning Frequency (H / V)

Sync Formats

Speakers

Input Terminals

Output Terminals

Sound Adjustment

Power Requirements

Maximum Power Consumption

Typical Power Consumption

Power Save Mode

Power Management

Preset Modes

Auto EcoView

OSD Languages

Others

Dimensions (Landscape, W x H x D)

Dimensions (Without Stand, W x H x D)

Net Weight

Net Weight (Without Stand)

Height Adjustment Range

Tilt

Swivel

Pivot

Hole Spacing (VESA Standard)

Temperature

Humidity (R.H., non condensing)

Certifications & Standards

Supplied Accessories

Warranty

Gray, Black

TN

LED

19" / 48 cm (481 mm diagonal)

1280 x 1024 (5:4 aspect ratio)

376.3 x 301.0 mm

0.294 x 0.294 mm

16.77 million from a palette of 1.06 billion

170°, 160°

250 cd/m

2

1000:1

5 ms (black-white-black)

D-Sub mini 15 pin, DVI-D 24 pin (with HDCP)

31 - 64 kHz, 59 - 61 Hz (VGA Text: 69 - 71 Hz)

31 - 80 kHz, 50 - 75 Hz

Separate, Sync on green

0.5 W + 0.5 W

3.5 mm stereo jack

3.5 mm headphone jack

Volume

AC 100 - 120 V / 200 - 240 V, 50 / 60 Hz

23 W

11 W

Less than 0.5 W

Power Save (VESA DPM and DVI DMPM), Eco Timer

FineContrast (Text, sRGB, EyeCare, Paper, Custom)

Yes

English, French, German, Italian, Japanese,

Simplified and Traditional Chinese, Spanish,

Swedish

Screen Adjustment (Clock, Phase, Position,

Range (Auto), Smoothing (5 stages), Color

Adjustment (Brightness, Contrast, Temperature,

Gain, Reset), Input Signal, Power Indicator,

Product Information (name, serial number, resolution, operating time, etc.), OSD Menu

Position, Adjustment Lock, DDC/CI Lock, Reset

With Height Adjustable Stand: 405 x 406.5 -

506.5 x 205 mm

With Tilt Stand: 405 x 416 x 205 mm

405 x 334 x 61.5 mm

With Height Adjustable Stand: 5.9 kg

With Tilt Stand: 4.9 kg

4.1 kg

With Height Adjustable Stand: 100 mm

With Tilt Stand: -

With Height Adjustable Stand: 30° Up, 0° Down

With Tilt Stand: 30° Up, 5° Down

With Height Adjustable Stand: 35° Right / 35° Left

With Tilt Stand: -

With Height Adjustable Stand: 90°

With Tilt Stand: -

100 x 100 mm

5 - 35 °C

20 - 80 %

TCO Displays 6.0, EPEAT Gold (except for Tilt

Stand version)/ Silver (Tilt Stand version) (US),

TUV/Ergonomics (including ISO9241-307),

TUV/GS, C-Tick, CE, CB, cTUVus, FCC-B,

Canadian ICES-003-B, TUV/S, VCCI-B, EPA Energy

Star, RoHS, WEEE, China RoHS, CCC, GOST-R

AC power cord, signal cables (D-Sub - D-Sub,

DVI-D - DVI-D), audio cable, setup guide,

CD-ROM (PDF user's manual, ScreenManager

Pro for LCD [DDC/CI], ScreenSlicer software)

Five Years

1 The usage time is limited to 30,000 hours or less, and the warranty period of the LCD panel is limited to three years from the date of purchase.

153 Shimokashiwano, Hakusan, Ishikawa 924-8566 Japan

Phone +81-76-277-6792 Fax +81-76-277-6793

www.eizo.com

All product names are trademarks or registered trademarks of their respective companies.

EIZO and FlexScan are registered trademarks of EIZO Corporation.

Specifications are subject to change without notice.

Copyright © 2013 EIZO Corporation. All rights reserved.

19" LED-Backlit Monitor Saves Energy and Reduces Eye Fatigue

LED Backlight

With an energy-saving LED backlight, the FlexScan S1903 uses only 11 watts during typical operation. The LED backlight does not contain any mercury for minimal environmental impact when the monitor is eventually disposed of.

Digital and Analog Inputs

With both DVI-D and D-Sub mini

15-pin inputs, you can use a computer that has either a digital or an analog graphics board (or

DVI-D D-Sub both if connected to two computers), and quickly switch between the inputs via a front panel button.

Built-In Speakers

0.5-watt speakers are tucked away at the back of the monitor and out of view so you can enjoy sound while bezel size is kept to a minimum. A headphone jack is also built into the monitor.

*NTSC signal

Compliance with International Labels

(US)

Auto Image Adjustment

The monitor discerns the input signal from the PC and automatically adjusts the clock, phase, image location, size, etc. In addition, the signal cables that are bundled were developed by EIZO to reduce noise.

Viewing Comfort with an Ergonomic Stand

Adjust the screen to the most comfortable position with 100 mm height adjustment, 30° tilt, 70° swivel, and 90° rotation for portrait mode. A basic stand that offers 35° of tilt is also available.

Height Adjustment Tilt Swivel Portrait

30°

90 °

Sync-On-Green Signal Support

Support for sync-on-green ensures this monitor can be used with legacy graphics boards that output this signal.

35° 35°

VESA Mount Version

For customers that will provide their own VESA-compatible mounting solutions, the FlexScan S1903 is available without a stand.

Optimized Brightness with Auto EcoView

The Auto EcoView function is a sensor on the front of the monitor that measures ambient light and optimizes the screen's brightness to a level akin to viewing a sheet of paper under typical office lighting conditions. Since the screen is never too bright, eye strain is reduced while power consumption is cut by up to 50% compared to operating the monitor with Auto EcoView turned off and set to the default factory brightness of 100%.

Anti-Glare Treatment

A non-glare screen reduces eye fatigue by dissipating reflective light that otherwise makes the screen difficult to view.

Furthermore, the surface of the bezels is treated to prevent light reflection.

Incident light

Reflected light

Reflected light

Glare panel

10-Bit Gamma Correction

Non-glare panel

This technology helps achieve accurate color by converting the 8-bit PC data to 10-bit, and assigning the ideal gamma values with a 10-bit look-up table (LUT) then returning the data to 8-bit format for display.

Screen brightness dimmed

in a dark environment

GAMMA CUR VE

Improved Work Efficiency, Reduced Visual Fatigue

EIZO conducted a survey to establish the relationship between eye fatigue and monitor use. The survey found that when you properly adjust your monitor’s brightness, the reduction in your ability to focus drops by half

(Graph 1). In addition, maintaining correct working posture and taking regular breaks further reduced fatigue levels and increased work efficiency by 12.5% (Graph 2).

Comparison between fatigue levels after monitor use

[%]

15

14.61

% 7.96 %

10

5

6.65

% 6.25 %

Average increase in near-point distance

0

0.4

1.Standard

2. Ideal

Quantity of VDT work per unit of time

[%]

115

110

105

100

95

100 %

7.9

% increase

4.6 %

104.6

112.5

0

1.Standard

2. Ideal

brightness

EIZO monitor features like Auto EcoView, ergonomic stands, and the EyeCare utility help reduce eye fatigue and increase work efficiency.

Ideal Gamma Curve

Uncorrected

Gamma Curve

Ideal Gamma Curve

256 Tones 256 Tones

Preset Modes for Optimum Viewing

With EIZO’s Fine Contrast function you can choose from several preset modes for the various applications you work with. Toggling between modes can be done manually in the

OSD menu or automatically by assigning a mode to a particular application with the bundled ScreenManager Pro for LCD software.

EyeCare Paper Text

Custom sRGB

Select the best mode depending on content

Text Mode

-

Custom Mode

Text Mode sRGB Mode

Paper Mode EyeCare Mode sRGB Mode

Switch modes in the OSD menu… switch automatically

Prevents Eye Fatigue in Dimly-Lit Offices

Fine Contrast includes an EyeCare mode that reduces the screen’s brightness to just 3 cd/m

2

. This ultra-low brightness helps prevent eye fatigue and increase productivity when working in an environment with very dim ambient lighting such as a CAD studio.

Closely Simulates Documents and Books

Paper mode simulates the look of printed paper by raising the black level and lowering the contrast ratio. Together with the Auto EcoView ambient brightness sensor, Paper mode reduces the amount of blue light emanating from the monitor for less eyestrain. (See page 4 for more information about Paper mode.)

Built to Last Five Years

EIZO’s five-year warranty is two years or 67% longer than the standard three-year warranty of most brands. Even if the initial purchase price of the FlexScan S1903 is higher than another 19-inch monitor, the TCO (total cost of ownership) will likely be lower due to the significantly longer buying cycle and less need for repair.

5-Year vs. 3-Year Warranty

Eye Care Utility

The EyeCare utility is EIZO

-developed software that helps promote better work habits. It consists of a function called

“EyeCare Reminder” that reminds you to take scheduled breaks.

Energy Savings across the Network

EIZO’s EcoView NET power management software provides centralized control over the power settings of monitors on a network. With EcoView NET, a systems administrator can confirm the settings for each monitor on the network, turn the power on or off, and if necessary, take measures to combat eye fatigue such as adjust the brightness or activate Auto

EcoView. EcoView NET is available from EIZO distributors.

Power save command

Network

Manager PC

Off!

On!

Made by EIZO

W hile outsourcing production is now common practice in the monitor industry, EIZO continues to manufacture its products the same way it has throughout its 40-year history – with its own staff at its own factories. This allows EIZO to maintain close control over production quality and offer the industry’s only 5-year manufacturer’s limited warranty.

Optimized Brightness with Auto EcoView

The Auto EcoView function is a sensor on the front of the monitor that measures ambient light and optimizes the screen's brightness to a level akin to viewing a sheet of paper under typical office lighting conditions. Since the screen is never too bright, eye strain is reduced while power consumption is cut by up to 50% compared to operating the monitor with Auto EcoView turned off and set to the default factory brightness of 100%.

Anti-Glare Treatment

A non-glare screen reduces eye fatigue by dissipating reflective light that otherwise makes the screen difficult to view.

Furthermore, the surface of the bezels is treated to prevent light reflection.

Incident light

Reflected light

Reflected light

Glare panel

10-Bit Gamma Correction

Non-glare panel

This technology helps achieve accurate color by converting the 8-bit PC data to 10-bit, and assigning the ideal gamma values with a 10-bit look-up table (LUT) then returning the data to 8-bit format for display.

Screen brightness dimmed

in a dark environment

GAMMA CUR VE

Improved Work Efficiency, Reduced Visual Fatigue

EIZO conducted a survey to establish the relationship between eye fatigue and monitor use. The survey found that when you properly adjust your monitor’s brightness, the reduction in your ability to focus drops by half

(Graph 1). In addition, maintaining correct working posture and taking regular breaks further reduced fatigue levels and increased work efficiency by 12.5% (Graph 2).

Comparison between fatigue levels after monitor use

[%]

15

14.61

% 7.96 %

10

5

6.65

% 6.25 %

Average increase in near-point distance

0

0.4

1.Standard

2. Ideal

Quantity of VDT work per unit of time

[%]

115

110

105

100

95

100 %

7.9

% increase

4.6 %

104.6

112.5

0

1.Standard

2. Ideal

brightness

EIZO monitor features like Auto EcoView, ergonomic stands, and the EyeCare utility help reduce eye fatigue and increase work efficiency.

Ideal Gamma Curve

Uncorrected

Gamma Curve

Ideal Gamma Curve

256 Tones 256 Tones

Preset Modes for Optimum Viewing

With EIZO’s Fine Contrast function you can choose from several preset modes for the various applications you work with. Toggling between modes can be done manually in the

OSD menu or automatically by assigning a mode to a particular application with the bundled ScreenManager Pro for LCD software.

EyeCare Paper Text

Custom sRGB

Select the best mode depending on content

Text Mode

-

Custom Mode

Text Mode sRGB Mode

Paper Mode EyeCare Mode sRGB Mode

Switch modes in the OSD menu… switch automatically

Prevents Eye Fatigue in Dimly-Lit Offices

Fine Contrast includes an EyeCare mode that reduces the screen’s brightness to just 3 cd/m

2

. This ultra-low brightness helps prevent eye fatigue and increase productivity when working in an environment with very dim ambient lighting such as a CAD studio.

Closely Simulates Documents and Books

Paper mode simulates the look of printed paper by raising the black level and lowering the contrast ratio. Together with the Auto EcoView ambient brightness sensor, Paper mode reduces the amount of blue light emanating from the monitor for less eyestrain. (See page 4 for more information about Paper mode.)

Built to Last Five Years

EIZO’s five-year warranty is two years or 67% longer than the standard three-year warranty of most brands. Even if the initial purchase price of the FlexScan S1903 is higher than another 19-inch monitor, the TCO (total cost of ownership) will likely be lower due to the significantly longer buying cycle and less need for repair.

5-Year vs. 3-Year Warranty

Eye Care Utility

The EyeCare utility is EIZO

-developed software that helps promote better work habits. It consists of a function called

“EyeCare Reminder” that reminds you to take scheduled breaks.

Energy Savings across the Network

EIZO’s EcoView NET power management software provides centralized control over the power settings of monitors on a network. With EcoView NET, a systems administrator can confirm the settings for each monitor on the network, turn the power on or off, and if necessary, take measures to combat eye fatigue such as adjust the brightness or activate Auto

EcoView. EcoView NET is available from EIZO distributors.

Power save command

Network

Manager PC

Off!

On!

Made by EIZO

W hile outsourcing production is now common practice in the monitor industry, EIZO continues to manufacture its products the same way it has throughout its 40-year history – with its own staff at its own factories. This allows EIZO to maintain close control over production quality and offer the industry’s only 5-year manufacturer’s limited warranty.

19" LCD Monitor

Optional LCD Panel Protector

This protector fits easily between the LCD screen and bezel, has a light transmission rate of more than 90%, and includes both an anti-glare coating side to reduce light reflection and a glossy side for crisper, more vibrant images.

What is Paper Mode?

Simply put, it is a mode which adjusts the brightness, contrast ratio, and color temperature of a monitor to simulate those of printed paper. Over the course of a work day PC users must constantly adjust to the difference between how monitors and paper appear. This overworks the muscles of the eyes and is thought to be a source of eye fatigue and stress. Paper mode was developed to alleviate the eye fatigue and stress that PC users feel.

Comparison between paper, EIZO square monitors, and Paper Mode

Brightness

Contrast Ratio

Newspaper

55 % reflection rate, 88 cd/m 2

*

6.2:1

Recycled Copy

Paper

70 % reflection rate, 112 cd/m 2

*

10.7:1

EIZO Square

Monitors

267 cd/m

2

1167:1 †

Paper Mode

50 - 70 % reflection rate

About 30:1

Color

Temperature

3,477 K 3,828 K

* Measured at an ambient brightness of 500 lx. brightness of FlexScan square monitors .

6500 K

(when shipped)

4,000 – 5,000 K

† Average maximum

Color Temperature, Brightness and the

Effect on Blue Light

In the visible light spectrum, blue light has wavelengths adjacent to ultraviolet light. Compared to the factory preset setting of 6,500 K of typical LCD monitors, Paper Mode is closer to the spectral distribution with long reddish wavelengths so it reduces the amount of blue light, a cause of eye fatigue.

Ultraviolet Light

Blue Light

400 - 500 nm

Visible Light Infrared Light

The combination of Paper Mode and the Auto EcoView brightness adjustment function reduces blue light even more. In a monitor with an LED backlight where Paper

Mode and Auto EcoView were used, the blue light was measured and found to have only 1/6 th factory setting.

the intensity of the

Intensity

(W/(sr m 2 nm))

1.2 E - 02

1.0 E - 02

8.0 E - 03

6.0 E - 03

4.0 E - 03

2.0 E - 03

0.0 E - 00

380

Initial measurement of sample unit: 350 cd/m 2 , 6,500 - 7,000 K

When using Auto EcoView and Paper Mode: 120 cd/m 2 , 5,000 K

430 480

Blue Light

530

Blue light reduced to 1/6

580 630 680 th

730

Wavelength (nm)

S P E C I F I C A T I O N S

Cabinet Colors

Panel Type

Backlight

Size

Native Resolution

Display Size (H x V)

Pixel Pitch

Display Colors

Viewing Angles (H / V, typical)

Brightness (typical)

Contrast Ratio (typical)

Response Time (typical)

Video Signals

Digital Scanning Frequency (H / V)

Analog Scanning Frequency (H / V)

Sync Formats

Speakers

Input Terminals

Output Terminals

Sound Adjustment

Power Requirements

Maximum Power Consumption

Typical Power Consumption

Power Save Mode

Power Management

Preset Modes

Auto EcoView

OSD Languages

Others

Dimensions (Landscape, W x H x D)

Dimensions (Without Stand, W x H x D)

Net Weight

Net Weight (Without Stand)

Height Adjustment Range

Tilt

Swivel

Pivot

Hole Spacing (VESA Standard)

Temperature

Humidity (R.H., non condensing)

Certifications & Standards

Supplied Accessories

Warranty

Gray, Black

TN

LED

19" / 48 cm (481 mm diagonal)

1280 x 1024 (5:4 aspect ratio)

376.3 x 301.0 mm

0.294 x 0.294 mm

16.77 million from a palette of 1.06 billion

170°, 160°

250 cd/m

2

1000:1

5 ms (black-white-black)

D-Sub mini 15 pin, DVI-D 24 pin (with HDCP)

31 - 64 kHz, 59 - 61 Hz (VGA Text: 69 - 71 Hz)

31 - 80 kHz, 50 - 75 Hz

Separate, Sync on green

0.5 W + 0.5 W

3.5 mm stereo jack

3.5 mm headphone jack

Volume

AC 100 - 120 V / 200 - 240 V, 50 / 60 Hz

23 W

11 W

Less than 0.5 W

Power Save (VESA DPM and DVI DMPM), Eco Timer

FineContrast (Text, sRGB, EyeCare, Paper, Custom)

Yes

English, French, German, Italian, Japanese,

Simplified and Traditional Chinese, Spanish,

Swedish

Screen Adjustment (Clock, Phase, Position,

Range (Auto), Smoothing (5 stages), Color

Adjustment (Brightness, Contrast, Temperature,

Gain, Reset), Input Signal, Power Indicator,

Product Information (name, serial number, resolution, operating time, etc.), OSD Menu

Position, Adjustment Lock, DDC/CI Lock, Reset

With Height Adjustable Stand: 405 x 406.5 -

506.5 x 205 mm

With Tilt Stand: 405 x 416 x 205 mm

405 x 334 x 61.5 mm

With Height Adjustable Stand: 5.9 kg

With Tilt Stand: 4.9 kg

4.1 kg

With Height Adjustable Stand: 100 mm

With Tilt Stand: -

With Height Adjustable Stand: 30° Up, 0° Down

With Tilt Stand: 30° Up, 5° Down

With Height Adjustable Stand: 35° Right / 35° Left

With Tilt Stand: -

With Height Adjustable Stand: 90°

With Tilt Stand: -

100 x 100 mm

5 - 35 °C

20 - 80 %

TCO Displays 6.0, EPEAT Gold (except for Tilt

Stand version)/ Silver (Tilt Stand version) (US),

TUV/Ergonomics (including ISO9241-307),

TUV/GS, C-Tick, CE, CB, cTUVus, FCC-B,

Canadian ICES-003-B, TUV/S, VCCI-B, EPA Energy

Star, RoHS, WEEE, China RoHS, CCC, GOST-R

AC power cord, signal cables (D-Sub - D-Sub,

DVI-D - DVI-D), audio cable, setup guide,

CD-ROM (PDF user's manual, ScreenManager

Pro for LCD [DDC/CI], ScreenSlicer software)

Five Years

1 The usage time is limited to 30,000 hours or less, and the warranty period of the LCD panel is limited to three years from the date of purchase.

153 Shimokashiwano, Hakusan, Ishikawa 924-8566 Japan

Phone +81-76-277-6792 Fax +81-76-277-6793

www.eizo.com

All product names are trademarks or registered trademarks of their respective companies.

EIZO and FlexScan are registered trademarks of EIZO Corporation.

Specifications are subject to change without notice.

Copyright © 2013 EIZO Corporation. All rights reserved.

19" LED-Backlit Monitor Saves Energy and Reduces Eye Fatigue

LED Backlight

With an energy-saving LED backlight, the FlexScan S1903 uses only 11 watts during typical operation. The LED backlight does not contain any mercury for minimal environmental impact when the monitor is eventually disposed of.

Digital and Analog Inputs

With both DVI-D and D-Sub mini

15-pin inputs, you can use a computer that has either a digital or an analog graphics board (or

DVI-D D-Sub both if connected to two computers), and quickly switch between the inputs via a front panel button.

Built-In Speakers

0.5-watt speakers are tucked away at the back of the monitor and out of view so you can enjoy sound while bezel size is kept to a minimum. A headphone jack is also built into the monitor.

*NTSC signal

Compliance with International Labels

(US)

Auto Image Adjustment

The monitor discerns the input signal from the PC and automatically adjusts the clock, phase, image location, size, etc. In addition, the signal cables that are bundled were developed by EIZO to reduce noise.

Viewing Comfort with an Ergonomic Stand

Adjust the screen to the most comfortable position with 100 mm height adjustment, 30° tilt, 70° swivel, and 90° rotation for portrait mode. A basic stand that offers 35° of tilt is also available.

Height Adjustment Tilt Swivel Portrait

30°

90 °

Sync-On-Green Signal Support

Support for sync-on-green ensures this monitor can be used with legacy graphics boards that output this signal.

35° 35°

VESA Mount Version

For customers that will provide their own VESA-compatible mounting solutions, the FlexScan S1903 is available without a stand.

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement