Installation/Owner’s Manual Model 9100 Vehicular Slide Gate Operator Use this manual for circuit board 4602-010 Revision A or higher. WA R 9100-065-Z-3-13 NI NG MO SE VIN RIO G US GAT Op er IN E C an ate JU AN d fre ga RY C e ofte on Do OR AUS pe ly wh op or not all le en DE E an ga op d ob te AT erat ow e gachild H struarea Do is te. ren ctio in pa not st to ns sig th play . ht wh and in ile in ga Re ga ga te te te ad area is pa ow mov th ne r’s ing.or wa man lk thro ua l an ug h d sa fety inst ru ctio ns CO N AN FOR SI/U MS L-32TO CE 5 N/C RTI SA FIED C2 VE 2.2 TO HIC NO UL . 24 CL AR AS 7 S CA GA TE MO DEL . 53 38 2 AT O HP RIA L VO LT OP ER SE R S AM PS MAX GAT PH AS E E LO Do AD orKi 60 ng , In c., Ingl ew Hz oo d, CA Date Installed: Installer/Company Name: Circuit Board Serial Number and Revision Letter: Phone Number: Leave Manual with Owner Copyright 2013 DoorKing, Inc. All rights reserved. TM UL 325 Compliant Copyright 2009 DoorKing, Inc. All rights reserved. SPECIFICATIONS Class of Operation Type of Gate UL 325 Class I, II, III, IV Vehicular Slide Gates Only Horsepower Voltage / Phase 1/2 HP 115 VAC Single-Phase Current Max Gate Weight (Installed level) Max Gate Length (Installed level) 5.4 Amps @ 120V 1000 Lbs. 30 Ft. Drive Sprocket Size #40 Chain Cycles Per Hour Speed Entrapment Protection 60 Per Hour Approximately 1 Ft. per Second Primary - Inherent entrapment sensing system (Type A) Use this manual for the Model 9100 operator with circuit board 4602-010 Rev A or higher ONLY. Gate Frame Secondary - Provision for connection of a non-contact sensor (Type B1) and/or a contact sensor (Type B2). 11.5” 12” WARNING MOVING GATE CAN CAUSE SERIOUS INJURY OR DEATH Operate gate only when gate area is in sight and free of people and obstructions. Do not allow children to play in gate area or operate gate. Do not stand in gate path or walk through path while gate is moving. Read owner’s manual and safety instructions. CONFORMS TO ANSI/UL-325 53382 1” Minimum CERTIFIED TO CAN/CSA C22.2 NO. 247 VEHICULAR GATE OPERATOR CLASS HP MODEL SERIAL VOLTS PHASE AMPS 60 Hz 24” MAX GATE LOAD DoorKing, Inc., Inglewood, CA Chain Height: Idler wheels in top position. 10.5” Concrete Pad 14.75” 4” Minimum Concrete Pad DoorKing, Inc. reserves the right to make changes in the products described in this manual without notice and without obligation of DoorKing, Inc. to notify any persons of any such revisions or changes. Additionally, DoorKing, Inc. makes no representations or warranties with respect to this manual. This manual is copyrighted, all rights reserved. No portion of this manual may be copied, reproduced, translated, or reduced to any electronic medium without prior written consent from DoorKing, Inc. 9100-065-Z-3-13 1 TABLE OF CONTENTS SPECIFICATIONS Slide Gate Requirements 4 Safety Information for Slide Gate Operators 5 ASTM 2200 Standard for Gate Construction 6 Important Safety Instructions 6 Instructions regarding intended installation: 6 Important Notices 7 UL325 Entrapment Protection 8 Glossary 9 SECTION 1 - INSTALLATION 10 1.1 Hardware for the Gate 10 1.2 Physical Stops for the Gate 10 1.3 Typical Gate Types 11 1.4 Operator Mounting Positions 12-15 1.5 Underground Conduit Requirements 15 1.6 Pad, Post or Ceiling Mount without / with J-Box Setup 16 1.7 Mounting Operator and Chain 17-18 1.8 Installation of Warning Signs 18 1.9 Chain Tray Kit 19 SECTION 2 - AC POWER TO OPERATOR(S) 20 2.1 High Voltage Wire Runs 20 2.2 High Voltage Terminal Connection 20 SECTION 3 - ADJUSTMENTS 3.1 4602 Circuit Board Description and Adjustments 3.2 DIP-Switch SW 1 and SW 2 Settings 2 1 21 21 22-23 9100-065-Z-3-13 TABLE OF CONTENTS 3.3 Automatic Open / Close Limit Adjustment 24 3.4 Clutch Adjustment 25 3.5 Inherent Reverse Sensor Adjustment 25 SECTION 4 - ENTRAPMENT AND SAFETY PROTECTION 4.1 UL 325 Terminal Description 4.2 Secondary Entrapment Protection Device Locations 4.3 Loop Detector Wiring SECTION 5 - WIRING 26 26 27-28 29 30 5.1 Main Terminal Description 30 5.2 Control Wiring for Single/Primary Operator 31 5.3 Auxiliary Device Wiring 32 5.4 Bi-Parting Gates Wiring - Dual Gate Operators 33 SECTION 6 - OPERATING INSTRUCTIONS 6.1 AC Power and Reset Switch 6.2 Shutdown Conditions 34 34 35-36 Soft Shutdown Hard Shutdown 6.3 Manual Gate Operation 31-37 Fail-Safe Manual Release System Fail-Secure Manual Release System Emergency Vehicle Access Conditions SECTION 7 - MAINTENANCE AND TROUBLESHOOTING 7.1 9100-065-Z-3-13 Maintenance 38 38 7.2 Troubleshooting 39-40 7.3 Accessory Items 41 Model 9100 Wiring Diagram 42 3 Illustrations not to scale. Slide Gate Requirements The operator is intended for installation only on gates used for vehicles. Pedestrians must be supplied with a separate access opening. The pedestrian access opening shall be designed to promote pedestrian usage. Locate the gate such that persons will not come in contact with the vehicular gate during the entire path of travel of the vehicular gate. (ref. UL 325 56.8.4.b) Adjacent fence that covers open gate position. XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX High Risk of Entrapment Area All openings of a horizontal slide gate are guarded or screened from the bottom of the gate to a minimum of six (6) feet (1.83 m) above the ground to prevent a 2 1/4 inch (57.2 mm) diameter sphere from passing through the openings anywhere in the gate and in that portion of the adjacent fence that the gate covers in the open position. (ref. ASTM F2200-11a, 6.1.2) Closed Gate Compliant openings less than 2 1/4”. Gate Support Post Rollers High Risk of Entrapment Area Note: Install screened wire mesh to a non-compliant gate AND non-compliant adjacent fence that covers open gate position (See above). Note: A filler post or barrier may need to be installed in the gap area to reduce the distance to 2 1/4 inches or less. A contact sensor should be installed in this area for safety. (See A on next page and page 27). 2 1/4” maximum gap area Less than 2 1/4” Screened Wire Mesh 72” (6 ft) minimum Non-compliant openings wider than 2 1/4”. A gap, measured in the horizontal plane parallel to the roadway, between a fixed stationary object nearest the roadway (such as a gate support post) and the gate frame when the gate is in either the fully open position or the fully closed position, shall not exceed 2 1/4 inch (57.2 mm). (ref. ASTM F2200 6.1.4) Gate Frame Gate Frame and Adjacent Fence Area 6 ft minimum XX XXX XXX XXX XXX XXX XXX Fall Over Bracket Gates shall be designed, constructed and installed to not fall over more than 45 degrees from the vertical plane, when a gate is detatched from the supporting hardware. Guide XXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX Gate Frame and Adjacent Fence Area 4 9100-065-Z-3-13 Safety Information for Slide Gate Operators Entrapment protection devices are required to reduce the risk of injury. Install sensors where the risk of entrapment or obstruction exists while gate is moving. Individual requirements will vary. See pages 26-29 for more information on typical layout locations and setup. Physical Stops Positive stops shall be required to limit travel to the designed fully open and fully closed positions. These stops shall be installed either at the top of the gate, or at the bottom of the gate where such stops shall horizontally or vertically project no more than is required to perform their intended function. Helps minimize the potential of entrapment during the back travel of the gate. 2 Contact Sensor (Reversing Edges) A Installed on the fence to help minimize the potential of entrapment between the gate and fence. A filler post or barrier MAY need to be installed between fence and gate. B Helps minimize the potential of entrapment during the back travel of the gate. Guide Rollers Moving Gate Can Cause Serious Injury or Death See previous page for more information. KEEP CLEAR! Gate may move at any time without prior warning. Do not let children operate the gate or play in the gate area. This entrance is for vehicles only. Pedestrians must use separate entrance. A Minimizes the potential of the gate closing when a vehicle is present. Number and placement of loops is dependent on the application. Warning Signs Separate Pedestrian Walkway 1 Minimizes the potential of the gate closing when a vehicle is present. Number and placement of loops is dependent on the application. C Moving Gate Can Cause Serious Injury or Death Fence Permanently mounted and easily visible from either side of the gate. 1 Reverse Loop Non-Secure Side of Gate Reverse Loop Closed Gate (Optional) will provide an open command to the gate operator(s) when a vehicle is exiting the property. Secure Side of Gate Automatic Exit Loop May be necessary on part of fence AND entire gate. See previous page for more information. Warning Sign B Minimizes the potential of the gate closing on vehicular or other traffic that loops cannot sense. Screened Wire Mesh XXX C Fence 2 XXXXXXXXX Minimizes the potential of the gate closing on vehicular or other traffic that loops cannot sense. It can be installed on the secure OR non-secure side of gate. High Risk of Entrapment Area Non-Contact Sensors (Photo Sensors) 1 Illustration not to scale. KEEP CLEAR! Gate may move at any time without prior warning. Do not let children operate the gate or play in the gate area. This entrance is for vehicles only. Pedestrians must use separate entrance. Physical Stop Located so pedestrians cannot come in contact with the vehicular gate. 9100-065-Z-3-13 5 ASTM F2200 Standard for Gate Construction Vehicular gates should be constructed and installed in accordance with ASTM F2200; Standard Specification for Automated Vehicular Gate Construction. For a copy of this standard, contact ASTM directly at 610-832-9585; [email protected]; or www.astm.org. Important Safety Instructions WARNING - To reduce the risk of injury or death: 1. READ AND FOLLOW ALL INSTRUCTIONS. 2. Never let children operate or play with gate controls. Keep the remote control away from children. 3. Always keep people and objects away from gate. NO ONE SHOULD CROSS THE PATH OF THE MOVING GATE. 4. Test the operator monthly. The gate MUST reverse on contact with a rigid object or stop or reverse when an object activates the non-contact sensors. After adjusting the force or the limit of travel, retest the gate operator. Failure to adjust and retest the gate operator properly can increase the risk of injury or death. 5. Use the emergency release only when the gate is not moving. 6. KEEP GATES PROPERLY MAINTAINED. Read the owner's manual. Have a qualified service person make repairs to gate hardware. 7. The entrance is for vehicles only. Pedestrians must use separate entrance. 8. SAVE THESE INSTRUCTIONS! Instructions regarding intended installation: • Install the gate operator only if: 1. The operator is appropriate for the construction of the gate and the usage class of the gate. 2. All openings of a horizontal slide gate are guarded or screened from the bottom of the gate to a minimum of 6 feet (1.83 m) above the ground to prevent a 2 ¼ inch (57.2 mm) diameter sphere from passing through the openings anywhere in the gate, and in that portion of the adjacent fence that the gate covers in the open position. 3. All exposed pinch points are eliminated or guarded. 4. Guarding is supplied for exposed rollers. • The operator is intended for installation only on gates used for vehicles. Pedestrians must be supplied with a separate access opening. The pedestrian access opening shall be designed to promote pedestrian usage. Locate the gate such that persons will not come in contact with the vehicular gate during the entire path of travel of the vehicular gate. • The gate must be installed in a location so that enough clearance is supplied between the gate and adjacent structures when opening and closing to reduce the risk of entrapment. Swinging gates should not open into public access areas. • The gate must be properly installed and work freely in both directions prior to the installation of the gate operator. Do not over-tighten the operator clutch, pressure relief valve or reduce reversing sensitivity to compensate for a damaged gate. • For gate operators utilizing Type D protection: 1. The gate operator controls must be placed so that the user has full view of the gate area when the gate is moving. 2. A warning placard shall be placed adjacent to the controls. 3. An automatic closing device (such as a timer, loop sensor, or similar device) shall not be employed. 4. No other activation device shall be connected. • Controls intended for user activation must be located at least ten feet (10’) away from any moving part of the gate and where the user is prevented from reaching over, under, around or through the gate to operate the controls. Outdoor or easily accessible controls should have a security feature to prevent unauthorized use. • The Stop and/or Reset button must be located in the line-of-sight of the gate. Activation of the reset control shall not cause the operator to start. • A minimum of two (2) WARNING SIGNS shall be installed, one on each side of the gate where easily visible. • For gate operators utilizing a non-contact sensor: 1. See the instructions on the placement of non-contact sensors for each type of application. 2. Care shall be exercised to reduce the risk of nuisance tripping, such as when a vehicle trips the sensor while the gate is still moving in the opening direction. 3. One or more non-contact sensors shall be located where the risk of entrapment or obstruction exist, such as the perimeter reachable by a moving gate or barrier. 6 9100-065-Z-3-13 • For gate operators utilizing contact sensors: 1. One or more contact sensors shall be located where the risk of entrapment or obstruction exist, such as at the leading edge, trailing edge, and post mounted both inside and outside of a vehicular horizontal slide gate. 2. One or more contact sensors shall be located at the bottom edge of a vehicular vertical lift gate. 3. One or more contact sensors shall be located at the pinch point of a vehicular vertical pivot gate. 4. A hardwired contact sensor shall be located and its wiring arranged so that the communication between the sensor and the gate operator is not subjected to mechanical damage. 5. A wireless contact sensor such as one that transmits radio frequency (RF) signals to the gate operator for entrapment protection functions shall be located where the transmission of the signals are not obstructed or impeded by building structures, natural landscaping or similar obstructions. A wireless contact sensor shall function under the intended end-use conditions. 6. One or more contact sensors shall be located at the bottom edge of a vertical barrier (arm). Important Notices Vehicular gate operator products provide convenience and security. However, gate operators must use high levels of force to move gates and most people underestimate the power of these systems and do not realize the potential hazards associated with an incorrectly designed or installed system. These hazards may include: • Pinch points • Entrapment areas • Reach through hazards • Absence of entrapment protection devices • Improperly located access controls • Absence of vehicle protection devices • Absence of controlled pedestrian access In addition to these potential hazards, automated vehicular gate systems must be installed in accordance with the UL 325 Safety Standard and the ASTM F2200 Construction Standard. Most lay persons are unaware of, or are not familiar with, these standards. If an automated vehicular gate system is not properly designed, installed, used and maintained, serious injuries or death can result. Be sure that the installer has instructed you on the proper operation of the gate and gate operator system. Be sure that the installer has trained you about the basic functions of the required reversing systems associated with your gate operating system and how to test them. These include reversing loops, inherent reversing system, electric edges, photoelectric cells, or other external devices. • This Owner’s Manual is your property. Keep it in a safe place for future reference. • Be sure that all access control devices are installed a minimum distance of 10 feet away from the gate and gate operator, or in such a way that a person cannot touch the gate or gate operator while using the device. If access control devices are installed in violation of these restrictions, immediately remove the gate operator from service and contact your installing dealer. • Loops and loop detectors, photo-cells or other equivalent devices must be installed to prevent the gate from closing on vehicular traffic. • The speed limit for vehicular traffic through the gate area is 5 MPH. Install speed bumps and signs to keep vehicular traffic from speeding through the gate area. Failure to adhere to posted speed limits can result in damage to the gate, gate operator, and to the vehicle. • Be sure that all persons who will use the gate system are familiar with the proper use of the gate and gate operator and are familiar with the possible hazards associated with the gate system. • Be sure that warning signs are permanently installed on both sides of the gate in an area where they are fully visible to traffic. • It is your responsibility to periodically check all entrapment protection devices. If any of these devices are observed to function improperly, remove the operator from service immediately and contact your installing or servicing dealer. • Follow the recommended maintenance schedule. • Do not allow children to play in the area of the operator or to play with any gate-operating device. • To remove the gate operator from service, operate the gate to the full open position and then shut off power to the operator at the service panel. 9100-065-Z-3-13 7 UL 325 Entrapment Protection Class I Class II A vehicular gate operator (or system) intended for use in a home of one-to four single family dwelling, or a garage or parking area associated therewith. A vehicular gate operator (or system) intended for use in a commercial location or building such as a multi-family housing unit (five or more single family units) hotel, garages, retail store or other building servicing the general public. STATE PRISON Class III Class IV A vehicular gate operator (or system) intended for use in a industrial location or building such as a factory or loading dock area or other locations not intended to service the general public. A vehicular gate operator (or system) intended for use in a guarded industrial location or building such as an airport security area or other restricted access locations not servicing the general public, in which unauthorized access is prevented via supervision by security personnel. This table illustrates the entrapment protection requirements for each of the four UL 325 classes. UL 325 Classifications Horizontal Slide, Vertical Lift, Vertical Pivot Secondary Protection Primary Protection A B1, B2 or D A or C A, B1, B2, C or D Class III A, B1 or B2 A, B1, B2, D or E A, B1, B2 or C A, B1, B2, C or D Class IV A, B1, B2 or D A, B1, B2, D or E A, B1, B2, C or D A, B1, B2, C, D or E Class I and II Primary Protection Swing and Vertical Barrier (arm) Secondary Protection A - Inherent entrapment protection system. B1 - Provision for connection of, or supplied with, a non-contact sensor (photoelectric sensor or the equivalent). When used as the PRIMARY device, must be monitored. B2 - Provision for connection of, or supplied with, a contact sensor (edge device or the equivalent). When used as the PRIMARY device, must be monitored. C - Inherent adjustable clutch or pressure relief device. D - Provision for connection of, or supplied with, an actuating device requiring continuous pressure to maintain opening or closing motion of the gate. E - An inherent audio alarm. 8 9100-065-Z-3-13 Glossary GATE - A moving barrier such as a swinging, sliding, raising, lowering, or the like, barrier, that is a stand-alone passage barrier or is that portion of a wall or fence system that controls entrance and/or egress by persons or vehicles and completes the perimeter of a defined area. RESIDENTIAL VEHICULAR GATE OPERATOR – CLASS I - A vehicular gate operator (or system) intended for use in a home of one-to four single family dwelling, or garage or parking area associated therewith. COMMERCIAL / GENERAL ACCESS VEHICULAR GATE OPERATOR - CLASS II - A vehicular gate operator (or system) intended for use in a commercial location or building such as a multi-family housing unit (five or more single family units), hotels, garages, retail store, or other building servicing the general public. INDUSTRIAL / LIMITED ACCESS VEHICULAR GATE OPERATOR - CLASS III - A vehicular gate operator (or system) intended for use in an industrial location or building such as a factory or loading dock area or other locations not intended to service the general public. RESTRICTED ACCESS VEHICULAR GATE OPERATOR - CLASS IV - A vehicular gate operator (or system) intended for use in a guarded industrial location or building such as an airport security area or other restricted access locations not servicing the general public, in which unauthorized access is prevented via supervision by security personnel. VEHICULAR BARRIER (ARM) OPERATOR (OR SYSTEM) - An operator (or system) that controls a cantilever type device (or system), consisting of a mechanical arm or barrier that moves in a vertical arc, intended for vehicular traffic flow at entrances or exits to areas such as parking garages, lots or toll areas. VEHICULAR HORIZONTAL SLIDE-GATE OPERATOR (OR SYSTEM) - A vehicular gate operator (or system) that controls a gate which slides in a horizontal direction that is intended for use for vehicular entrance and exit to a drive, parking lot, or the like. VEHICULAR SWING-GATE OPERATOR (OR SYSTEM) - A vehicular gate operator (or system) that controls a gate which moves in an arc in a horizontal plane that is intended for use for vehicular entrance and exit to a drive, parking lot, or the like. SYSTEM - In the context of these requirements, a system refers to a group of interacting devices intended to perform a common function. WIRED CONTROL - A control implemented in a form of fixed physical interconnections between the control, the associated devices, and an operator to perform predetermined functions in response to input signals. WIRELESS CONTROL - A control implemented in means other than fixed physical interconnections (such as radio waves or infrared beams) between the control, the associated devices, and an operator to perform predetermined functions in response to input signals. INHERENT ENTRAPMENT PROTECTION SYSTEM - A system, examples being a motor current or speed sensing system, which provides protection against entrapment upon sensing an object and is incorporated as a permanent and integral part of the operator. EXTERNAL ENTRAPMENT PROTECTION DEVICE - A device, examples being an edge sensor, a photoelectric sensor, or similar entrapment protection device, which provides protection against entrapment when activated and is not incorporated as a permanent part of an operator. ENTRAPMENT - The condition when an object is caught or held in a position that increases the risk of injury. 9100-065-Z-3-13 9 SECTION 1 - INSTALLATION Prior to beginning the installation of the slide gate operator, we suggest that you become familiar with the instructions, illustrations, and wiring guide-lines in this manual. This will help insure that your installation is performed in an efficient and professional manner compliant with UL 325 safety and ASTM F2200 construction standards. The proper installation of the vehicular slide gate operator is an extremely important and integral part of the overall access control system. Check all local building ordinances and building codes prior to installing this operator. Be sure your installation is in compliance with local codes. 1.1 Hardware for the Gate Good hardware is essential for proper operation of a sliding gate. DoorKing has a full line of gate hardware products that will ensure safe, reliable and long lasting gate operation. The gate must be properly installed and roll smoothly in both directions. Roller Bearing V-Wheels with Protective Cover - Helps to minimize a pinch point on the gate’s wheel and V-rail. Guide Rollers with Protective Covers - Helps to minimize a pinch point on the gate. Endless Idler Assembly with Protective Cover - Helps to minimize a pinch point for a 180° chain return. Gate End Retainer - Helps stabilize the end of the gate in the open or closed position. Recommended for all slide gate applications. 1.2 Physical Stops for the Gate The 9100’s automatic open/close gate limits must have a physical stop on the open and close positions of the gate. This can be the use of end posts with gate end retainers or chain stops, depending on the mounting position of the operator. Chain stops DO NOT meet the ASTM F2200 requirements. Gate End Retainer Rubber bumper faces toward operator. it will make contact with the operator housing during the initial automatic “Multiple gate cycling” to set the open and close gate position. Chain Stops End Post Ga te 10 9100-065-Z-3-13 1.3 Typical Gate Types The Model 9100 operator is designed to be installed on these gate types. See the next 4 pages for specific operator mounting positions. Individual installations and physical stops can vary. • • • • 1000 lb. max. weight per gate. Single Operator - 30 ft max. gate length. Dual Operators - 60 ft max. total gate length. Chain tray recommended for gates longer than 20 ft using front or center post mount installations ONLY. er v tile n Ca WAR NING MOVING SERIOUS GATE Operate INJURY CAN and free gate CAUSE of only OR Do people when DEATH or not allow and gate operate area children obstructions. Do gate. is in pathnot stand to sight play while in in gate Read gate gate area path owner’s is moving. or walk manual through and safety CONFORMS ANSI/UL-325 TO CAN/CSA CERTIFIED instructions. C22.2 TO VEHICULAR NO. 53382 247 CLASS GATE OPERATOR MODEL SERIAL HP VOLTS AMPS MAX GATE LOAD DoorKing, PHASE 60 Hz Inc., Inglewood, CA n. ow ate. h s g t r ounps fo m t o t pos l s ith ysica w h tion s p osi sed a p u nt Fro stops n ai Ch er v tile an C me x Bo Fra WARN ING MOVING SERIOUS GATE Operate INJURY CAN and free gate CAUSE of only OR Do people when DEATH or not allow and gate operate area children obstructions. Do gate. is in pathnot stand to sight play while in in gate Read gate gate area path owner’s is moving. or walk manual through and safety instructions. CONFORMS ANSI/UL-325 TO CAN/CSA CERTIFIED C22.2 TO VEHICULAR NO. 53382 247 CLASS GATE OPERATOR MODEL SERIAL HP VOLTS AMPS MAX GATE LOAD DoorKing, PHASE 60 . wn te. o h t s r ga ounps fo m ost sto h p sical t i w hy tion as p i s po used nt Fro stops ain Ch Hz Inc., Inglewood, CA . wn r lle o R me a V-R ra F ox B ho ys. a r in t ate cha for g d an ps unt al sto o t m sic pos s phy h wit d a on s use i t i p os t p in sto n o a Fr Ch WARN ING MOVING SERIOUS GATE Operate INJURY CAN and free gate CAUSE of only Do people when OR DEATH or not allow and gate operate area children obstructions. Do gate. is in pathnot stand to sight play while in gate in Read gate gate area path owner’s is moving. or walk manual through and safety instructions. CONFORMS ANSI/UL-325 TO CAN/CSA CERTIFIED C22.2 TO VEHICULAR NO. 53382 247 CLASS GATE OPERATOR MODEL SERIAL HP VOLTS AMPS MAX GATE LOAD DoorKing, PHASE 60 Hz Inc., Inglewood, CA i W l V- he rn O l e a n me tal . ate rg . wn ps fo o h o s t ad l s e p ysica t e cr ph con d as h t e wi us on osts i t i pos d p nt on en o r F rs ine t ea WAR NING MOVING SERIOUS GATE Operate INJURY CAN and free gate CAUSE of only OR Do people when DEATH or not allow and gate operate area children obstructions. Do gate. is in pathnot stand to sight play while in in gate Read gate gate area path owner’s is moving. or walk manual through and safety CONFORMS ANSI/UL-325 TO CAN/CSA CERTIFIED instructions. C22.2 TO VEHICULAR NO. 53382 247 CLASS GATE OPERATOR MODEL SERIAL HP VOLTS AMPS MAX GATE LOAD DoorKing, PHASE 60 Hz Inc., Inglewood, CA nd e ate r G 9100-065-Z-3-13 11 1.4 Operator Mounting Positions The Model 9100 operator is designed to be installed in the front, rear, center or ceiling mounting positions shown on this page and the next 3 pages. V-wheel V-rail ornamental gates are shown as examples but other gate types on the previous page can use the same mounting setups. Once the mounting position has been determined, the chain idler wheels may need to be adjusted BEFORE the operator is mounted. Physical stops MUST be used in the open AND close positions for ANY gate installation (Chain stops, end posts with gate end retainers or a wall that the gate comes in contact with). Front Position with Concrete Pad Chain Setup Standard method of installation. • Operator’s chain idler wheels are factory set for the front position. • Remove only the top chain knockouts from each side of the operator. • Chain stops or gate end retainer can be used as the physical stop for the gate (Chain stops are shown). Top View Chain Idler Wheels Chain Stop A filler post or barrier may need to be installed between the gate and wall area (See page 4 for more information). Front Position with Post Mount Raises operator and allows different chain heights. Optional chain tray kit can be used and is recommended for gates over 20 ft, supports the chain’s weight and helps prevent chain “stretching”. See page 19 for more information. Chain Setup Gate End Retainer • Set operator chain idler wheels in the bottom position. • DO NOT remove chain knockouts. • Chain stops with base plate stop brackets or gate end retainer can be used as the physical stop for the gate (Both are shown, only one type is needed). Base Plate Stop Bracket Chain Idler Wheels Chain Stop Additional hardware required. Post base plate (P/N 2600-418) 4 x 4 steel posts not available from DoorKing. Base plate stop brackets (P/N 2600-970) bolts on post base plate when using chain stops. Optional chain tray kit (P/N 2601-270 10 ft section) and additional chain #40 (P/N 2600-442 - 20 ft. per box) may be needed. Top View Gate End Retainer 12 A filler post or barrier may need to be installed between the gate and wall area (See page 4 for more information). Gate End Retainer 9100-065-Z-3-13 Rear Position with Concrete Pad Hides the chain from outside the property looking in. Chain Setup • Set one chain Idler wheel at the top and one in the center position on one side of the operator. • Remove both chain knockouts from one side of the operator. • Chain stops or gate end retainer can be used as the physical stop for the gate (Chain stops are shown). Chain Idler Wheels Chain Stop Additional hardware required. Endless idler assembly (P/N 2600-818) and additional chain #40 (P/N 2600-442 - 20 ft. per box) may be needed. A filler post or barrier may need to be installed between the gate and wall area (See page 4 for more information). Top View End les s Idle r See page 18 for more information about endless idlers. Rear Position with Post Mount Hides the chain from outside the property looking in. • Chain setup is the same as above. Additional hardware required. Post base plate (P/N 2600-418) 4 x 4 steel posts not available from DoorKing. 9100-065-Z-3-13 13 Center Position with Post Mount Hides the chain from outside the property looking in. Optional chain tray kit can be used and is recommended for gates over 20 ft, supports the chain’s weight and helps prevent chain “stretching”. See page 19 for more information. Chain Setup • Set operator chain idler wheels in the bottom position. • DO NOT remove chain knockouts. Chain Idler Wheels Additional hardware required. Post base plate (P/N 2600-418) 4 x 4 steel posts not available from DoorKing. Endless idler assembly (P/N 2600-818). Additional chain #40 (P/N 2600-442 - 20 ft. per box). Gate end retainer (P/N 1204-004). A filler post or barrier may need to be installed between the gate and wall area (See page 4 for more information). Top View Note: Chain stops CANNOT be used for this installation. End post with a gate end retainer must be installed as the physical stop if gate does not have any other means of a physical stop in the open and close position. Ga te Re End tain er En dl Idl ess er End Po st En dl Idl ess er See page 18 for more information about endless idlers. Gate in Close Position Gate shown in open position. Gate in Open Position 14 Optional Chain Tray Kit for Long Gates Optional chain tray kit (P/N 2601-270) can be used and is recommended for gates over 20 ft, see page 19 for more information. 9100-065-Z-3-13 Front or Rear Position Ceiling Mount Can be mounted on the ceiling to conserve floor space. Ceiling • Operator’s setup is the same as the front position or rear position with concrete pad shown on page 12 and 13. (Front position ceiling mount shown here). • Junction box connection is used for the ceiling mount installation. Chain Setup Chain Idler Wheels Chain Stop Note: There are NO fluids in the operator that can leak out. Top View A filler post or barrier may need to be installed between the gate and wall area (See page 4 for more information). Operator Bottom 1.5 Underground Conduit Requirements Primary Operator Position Secondary Operator Position DoorKing’s Primary/Secondary Interconnection Cable (Dual Operator Application Only) (Secondary Power and Communication wires) Control and/or P.A.M.S. Wires (Low Voltage wire insulation) Loop Lead-In Wires (Low Voltage wire insulation) Concrete Pad AC Input Power (High Voltage wire insulation) AC Input Power (High Voltage wire insulation) Sweeps 3/4 Inch Conduit Recommended • The conduit requirements are for a typical slide gate operator installation (the secondary operator is shown for those applications where a secondary operator may be used). The conduit requirements for your application may vary from this depending on your specific needs. • Use only sweeps for conduit bends. Do not use 90° elbows as this will make wire pulls very difficult and can cause damage to wire insulation. Sweep • DoorKing recommends using 3/4-inch conduit. YES Elbow • Be sure that all conduits are installed in accordance with local codes. NO • Never run low voltage rated wire insulation in the same conduit as high voltage rated wire insulation. 9100-065-Z-3-13 15 1.6 Pad, Post or Ceiling Mount without/with J-Box Setup Pad Mount with Conduit 1” minimum from operator housing to gate. 2.5” Conduit Area 11” Concrete pad MUST be level. 4” Solenoid Lock 15” Min. 4” min. above ground. Electronic Box Center Pad Underground depth of the concrete pad is determined by soil conditions and local building codes. Reinforced concrete recommended. 21” Min. Concrete Pad Concrete Conduit Post Mount with Conduit 12” Min. Conduit area inside post. Conduit area inside post. Base Plate P/N 2600-418 Concrete Foundation 1” minimum from operator housing to gate. Base Plate MUST be level. 21” Min. Note: Weld the posts to the base plate and mount assembly into concrete BEFORE attaching the operator. Conduit runs up through 4 x 4 steel posts. 4” min. above ground. Underground depth of the concrete foundation is determined by soil conditions and local building codes. Reinforced concrete recommended. Concrete Foundation Conduit Pad, Post or Ceiling Mount Connected with Junction Boxes All wire connections can be made on either side of the operator housing after it has been installed. WARNING MOVING GATE CAN CAUSE SERIOUS INJURY OR DEATH Operate gate only when gate area is in sight and free of people and obstructions. Do not allow children to play in gate area or operate gate. Operator MUST be level. Read owner’s manual and safety instructions. CONFORMS TO ANSI/UL-325 53382 CERTIFIED TO CAN/CSA C22.2 NO. 247 VEHICULAR GATE OPERATOR CLASS Note: Operator must be mounted 1” min. away from gate. Conduit Low Volt Low Volt Pad, post or ceiling mount High Volt HP MODEL SERIAL VOLTS PHASE AMPS 60 Hz MAX GATE LOAD DoorKing, Inc., Inglewood, CA 1/2 High Volt 16 Do not stand in gate path or walk through path while gate is moving. Never run high voltage and low voltage in the same conduit. 3/4 Fail-Secure Key Lock 1/2 1/2 1/2 1/2 3/4 Conduit Knock-Out Sizes Conduit 9100-065-Z-3-13 1.7 Mounting Operator and Chain Prior to mounting the operator, be sure that the correct chain knockouts have been removed and chain idler wheels are in the correct position (top, center or bottom). Fail-Secure Manual Release Kit Installation Note: It is easier to install the 2600-862 fail-secure manual release kit before mounting the operator and attaching the chain. Refer to the instruction sheet supplied with the kit for installation. Positioning Operator and Chain Brackets 1” minimum from operator housing to gate. Chain Bracket Lines up with Idler Wheels NO Operator MUST be parallel to gate! Chain Idler Wheels Operator NOT parallel to gate. YES Chain bracket MUST line up with chain idler wheels! NO Chain brackets MUST be mounted so the chain remains the same height as it is on the idler wheels! YES Chain brackets positioned too high. NO Chain Idler Wheels 10.5” 10.5” Chain idler wheels in top position. Chain brackets positioned too low. Correct Chain Bracket Height 10.5” Gate Frame Correct Chain Bracket Height Chain Bracket Attaching Operator to Concrete 3/8 DoorKing recommends a minimum of four (4) 3/8” x 2” sleeve anchors (not supplied). Chain bracket does NOT align with idler wheels. n1 tio Op Connect Chain Bracket to Gate. Weld completely around bracket. Chain nut and chain bolt should not protrude past gate frame. n2 tio Op Chain Nut r ste Ma ink L Chain Bolt Connect Chain to Chain Bracket. Lock Washer Washers 9100-065-Z-3-13 Attaching Operator to Post Base Plate Use six (6) 1/2”-13 x 1 1/2” bolts, lockwashers and nuts (not supplied). Connect chain to chain bolt with master link. Adjust the chain nuts to tighten the chain. The chain should sag no more than one (1) inch per 10 feet of travel. Do not over tighten the chain. 17 Endless Idler Assembly (On Select Installations) DoorKing offers an endless idler assembly with a protective cover designed for the Model 9100 installations (P/N 2600-818). Make sure the endless idler assembly is securely fastened to the wall or post (Depending on which type of installation will be used). Extreme force will be exerted on this assembly during gate cycling. Center and Rear Mount Positions (Top View) NO Gate Rail Operator Idler Wheel Lower chain MUST align with upper chain! Chain Brackets YES Endless Idler Center Mount Position (Side View) Operator Idler Wheel Lower chain does NOT align with upper chain. Note: Be sure that the chain is aligned and parallel to the gate. Installing the chain in any other manner will cause excessive noise, chain idler wheel wear and chain stretching. YES NO Upper Chain Lower Chain Chain Bracket Lower chain mounted Too High. Chain Return 1” Chain Bracket Lower chain MUST be 1 inch lower than the endless idler’s 180° chain return. NO Endless Idler Lower chain mounted Too Low. Gate Rail Rear Mount Position (Side View) YES NO Upper Chain Operator Idler Wheels Lower Chain Chain Bracket Chain Return Chain Bracket Endless Idler Lower chain mounted Too High. NO Gate Rail Upper and lower chain MUST be the same height as they are on the operator idler wheels. Lower chain mounted Too Low. 1.8 Installation of Warning Signs This DoorKing Slide Gate Operator is shipped with two warning signs. The purpose of the warning sign is to alert uninformed persons, and to remind persons familiar with the gate system, that a possible hazard exists so that appropriate action can be taken to avoid the hazard or to reduce exposure to the hazard. See page 5 for suggested mounting positions of signs. • Permanently install the supplied warning signs in locations so that the signs are visible by persons on both sides of the gate. • Use appropriate hardware such as wood or sheet metal screws (not supplied) to install the warning signs. 18 9100-065-Z-3-13 1.9 Chain Tray Kit Installing the Chain Tray Kit A chain tray is recommended for gates longer than 20 ft. to support the weight of the chain. DoorKing offers a chain tray kit in sections to fit any length gate. (DoorKing P/N 2601-270 10 Ft. section) Chain Tray Supporting Bracket (Facing up) Ft. Carriage Bolts Se gm ent Weep Hole Chain Tray Segments Connection 10 Ft. Se gm ent Chain Tray Supporting Bracket (Facing down) Tip: Chain tray supporting brackets can be mounted facing up (as shown on right), facing down or extended depending on the chain height and position. For further information, refer to instructions provided with the chain tray kit. Gate 10 1” Note: The chain should sag at least one (1) inch per 10 feet of travel. Post base plate (P/N 2600-418) Base Plate Stop Brackets (P/N 2600-970) when using chain stops. Note: All gate types can have the chain tray installed on them, V-rail V-wheel ornamental is shown here. 9100-065-Z-3-13 Chain Tray Supporting Bracket 19 SECTION 2 - AC POWER TO OPERATOR(S) Before attempting to connect any wiring to the operator, be sure that the circuit breaker in the electrical panel is in the OFF position. Permanent wiring must be installed to the operator as required by local electrical codes. It is recommended that a licensed electrical contractor perform this work. Since building codes vary from city to city, we highly recommend that you check with your local building department prior to installing any permanent wiring to be sure that all wiring to the operator (both high and low voltage) complies with local code requirements. THIS GATE OPERATOR MUST BE PROPERLY GROUNDED!! 2.1 High Voltage Wire Runs If power wiring is greater than the maximum distance shown, it is Never run low voltage rated wire insulation in the recommended that a service feeder be installed. When large gauge wire same conduit as high voltage rated wire insulation. is used, a separate junction box must be installed for the operator Wire Size / Max Distance in Feet connection. The wire table is based on stranded copper wire. Wire run calculations are based on a power source 12 AWG 10 AWG 8 AWG 6 AWG with a 3% voltage drop on the power line, 170 275 460 685 Single 9100: 5.4 Amp Motor plus an additional 10% reduction in distance 85 135 230 340 Dual 9100’s, Single Power Source to allow for other losses in the system. “Optional” 3.3 Amp Heater Installation Note: When installing the heater(s), refer to the “high voltage AC power wire size and distance requirements” table on the instruction sheet with the heater kit (P/N 1601-154) for AC power wire run requirements. 2.2 High Voltage Terminal Connection • Route incoming AC power wire through the high voltage conduit and run wire in the operator as shown. Dual Operators • Be sure wiring is installed in accordance with local codes. Be sure to color code all wiring. • It is recommended that a surge suppressor be installed on the high voltage power lines to help protect the operator and circuit board from surges and power fluctuations. AC Power MOV - Helps • Dual operators (Primary/Secondary) require AC power to EACH operator. protect operator from power surges. DO NOT power up and cycle the 46DOOR 02 KI -010 NG SW ITC H Hot Neu Chassis Ground White - Neutral Black - 115 VAC Hot Green - Chassis Ground High Voltage AC Power Wire OP TIME EN R 1 SW HIGH VOLTAGE 115 VAC Connection EXIT LOOP L und oose er n th th e to e ele 2 nu sw ctr ts ing on box ic b up. ox SW 115 VAC AC Power Terminal DANGER operator until the “Physical stops” have been installed. Damage could occur to the gate and operator. KEY AC Power REVE LOOP RS E 2 REVE SENS RS ITIV E IT Y Use the wire restrainers inside operator to keep wire away from moving parts. External Power Disconnect Switch A separate power disconnect switch may be needed in your area. Check local building codes before installation. AC POWER ON OFF High Voltage Conduit Every time the operator is powered up, the First open command will automatically run “Multiple gate cycles” that will locate and remember the gate’s open and close positions (See page 24). 20 9100-065-Z-3-13 SECTION 3 - ADJUSTMENTS The switch settings and adjustments in this chapter should be made after your installation and wiring to the operator(s) is complete. Whenever any of the programming switches on the circuit board are changed, power must be shut-off, and then turned back on for the new setting to take effect. Every time the 9100 is powered up, the First open command will automatically run “Multiple gate cycles” that will locate and remember the gate’s open and close positions (See page 24). 3.1 4602 Circuit Board Description and Adjustments Surface Mounted LEDs Indicates that low voltage power is applied to the circuit board. Input LEDs should be OFF and will only illuminate when the input is activated. Pulse LEDs will blink as the operator is running. They can be either ON or OFF when the operator is stopped. Dual Channel Loop Detector ON Auto-close timer (when turned on) SW 1, switch 2. 1 2 3 4 5 6 7 8 Auto-Close Timer 9410 9409 SW 1 Adjust from 1 second (full counter clockwise) to approximately 23 seconds (full clockwise). Single Channel Loop Detector 1 See page 33. Exit Loop Port 23 Reverse Loop Port 1 Cycles the operator when pressed. Gate opens to full open position ONLY. 6 7 8 9 Dry Relay Contact OPEN TIMER Power LED DOORKING 4602-010 1 2 3 4 5 C N O UL 325 Terminal 16 17 18 NC NO SW1 SW2 Pulse LEDs REVERSE SENSITIVITY Magnetic Sensors SW 1 See page 25. DIP-Switches SW 1 ON SW 1 1 2 3 4 5 6 7 8 ON Do not run self-test with the operator connected to the gate. The drive chain must be disconnected before running the self-test. This feature is designed for bench testing ONLY. Typical Settings Set the DIP-switches on the circuit board to the desired setting. See switch setting charts on next 2 pages. 1 2 3 4 5 6 7 8 CAUTION 9100-065-Z-3-13 ON 13 14 15 ON ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 Self-Test Self-test (when turned on) SW 1, switch 6. EXIT LOOP KEY SWITCH 10 11 12 N Dry relay contacts (terminals 15-16) can be set for Normally Open (NO) or Normally Closed (NC) operation by placing the relay shorting bar on the N.O. or N.C. pins respectively. SW 1, switches 4 and 5 must be set to control relay. See next page for descriptions. REVERSE LOOP Input LEDs Key Switch 2 3 4 5 See page 29. SW 2 Inherent Reverse Sensor Adjust reversing sensitivity. Full counter clockwise for minimum sensitivity, full clockwise for maximum sensitivity. See page 25. Min Max Sensitivity 21 3.2 DIP-Switch SW 1 and SW 2 Settings The two DIP-switches located on the circuit board are used to program the operator to operate in various modes and to turn on or off various operating features. Whenever a switch setting is changed, power to the operator must be turned OFF and then turned back on for the new setting to take affect. Check and review ALL switch settings prior to applying power to the operator. Every time the operator is powered up, the First open command will automatically run “Multiple gate cycles” that will locate and remember the gate’s open and close positions (See page 24). SW 1 (Left 8 Switches) Switch Function Setting Description Changes the direction the operator will open/close the gate depending on the different chain configurations. Front 1 Opening direction using ON setting. Mount 2 Auto-Close Timer 3 Motor Hold Opening direction using OFF setting. Opening direction using OFF setting. Center or Post Mounts Opening direction using ON setting. Opens with All Rear All Rear Mounts Left Mounts Right OFF setting. Opens with ON setting. OFF Auto-close timer is OFF. Manual input required to close gate. ON Auto-close timer is ON. Adjustable from 1-23 seconds to close gate. OFF Normal Setting. No voltage to motor when gate is stopped (Level gate). ON Voltage applied to motor always. Keeps inclined gate from coasting when stopped. Relay Activation 4-OFF 5-OFF Relay activates and LED is ON when the gate is fully open. and 4-OFF 5-ON Relay activates and LED is ON when the gate is not closed. 4 and 5 LED Indicator 4-ON 5-OFF Relay activates and LED is ON when the gate is opening and open. Light Activation 4-ON 5-ON Relay activates and LED is ON when the gate is opening and closing. OFF Normal Setting. 6 Self-Test ON Runs self-test. Caution: Bench testing ONLY! 7 and 8 Gate Open Back-Off Position 7-OFF 7-OFF 7-ON 7-ON 8-OFF 8-ON 8-OFF 8-ON Normal Setting. Gate fully opens. Gate stops short 1” from full open position. Used for a reversing edge device. Gate stops short 2” from full open position. Used for a reversing edge device. Gate stops short 3” from full open position. Used for a reversing edge device. SW 1 Switch 1 Must OPEN the gate upon initial AC power up and open command. If the first open command begins to close the gate, turn AC power off and reverse this switch. Opening direction will vary depending on the type of installation (See above). SW 1 Switch 2 Turns the auto-close timer on or off. Can be adjusted from 1 to 23 seconds to close gate. SW 1 Switch 3 This switch should be left in the OFF position when the slide gate is running on a level track and the gate does not coast after it has stopped. If the gate is on an incline, turning this switch on will apply a small DC voltage to the motor windings after the gate has stopped. This applies braking power to the motor to prevent the gate from “coasting” after it has stopped. SW 1 Switches 4-5 These work in conjunction with each other and determine when the relay on the board will be activated. This relay can be used as a switch for various functions such as illuminating a warning light when the gate is moving, or turning on a green light when the gate is full open. If a magnetic lock is used with the gate operator, these switches must be set for magnetic lock operation which limits the relay to activate only when the gate is opening and full open. SW 1 Switch 6 This switch is a self-test feature that checks various functions of the circuit board and is used for bench test only. Do not run this test with the operator connected to the gate. SW 1 Switches 7-8 These work in conjunction with each other and determine if the operator will stop the gate at the full open position, or if the gate should stop 1, 2 or 3 inches short of the full open position. Needed only when using a reversing edge entrapment protection device on the opening edge of the gate with an end post as the physical stop. 22 9100-065-Z-3-13 3.2 Continued SW 2 (Right 8 Switches) Switch Function 1 Exit Loop Port Output Setting Jumper Wire Needed Full Open Input 2 Stops Gate Partial Open (14 Ft) 4 Built-in Solenoid Lock 5 Operator Model Select 6 Quick-Close Timer Override 7 and 8 Gate Close Back-Off Position OFF A plug-in exit loop detector plugged into the EXIT Loop port will partially open single operator or fully open dual operators depending on type of loop detector used). ON Normal Setting. Plug-in exit loop detector will fully open gate (Single operator). OFF Normal Setting. Input to terminal #6 and/or reverse loops will reverse gate during close cycle. ON Input to terminal #6 and/or reverse loops will stop gate during close cycle – gate will continue to close after input to terminal #6 and/or reverse loops are cleared (Helps prevent tailgating vehicles from unauthorized entry). Reverses Gate 3 Description OFF Normal Setting. Switch must be OFF for terminal #5 input to open gate 14 Ft. ON DO NOT use ON setting. NOT associated with partial open feature for the 9100. OFF Normal Setting. Fail-safe logic. Lock engages only if attempt is made to force gate open (Factory setup). ON Fail-secure logic. Lock engages after each gate cycle (2600-862 Lock kit required). OFF ON OFF ON 7-OFF 7-OFF 7-ON 7-ON 8-OFF 8-ON 8-OFF 8-ON Normal Setting. Switch must be OFF for Model 9100. DO NOT use ON setting for Model 9100. Normal Setting. Timer will function normally. Opening gate will stop and begin to close as soon as all reversing inputs (Reverse loops, photo sensors) are cleared regardless of the distance the gate has opened. Normal Setting. Gate fully closes. Gate stops short 1” from full close position. Used for a reversing edge device. Gate stops short 2” from full close position. Used for a reversing edge device. Gate stops short 3” from full close position. Used for a reversing edge device. SW 2 Switch 1 Switch 1 ON, plug-in exit loop detector is a normal full open input. Switch 1 OFF, the normal exit loop port function is bypassed and a jumper wire is needed to open and close gate(s) for certain applications (Single operator automatic exit loop partial open or dual operator application) depending on the type of loop detector used and position of jumper wire. SW 2 Switch 2 Determines if an input to terminal #6 (Photo Sensors) AND/OR reverse loops will reverse OR stop a CLOSING gate. A tailgating vehicle can activate terminal #6 (Photo sensors) and/or reverse loops while the gate is in the closing cycle from the previous vehicle’s authorized entry: If switch 2 is turned OFF (Reverse), the closing gate that gets activated by a tailgating vehicle will reverse back to the open position, possibly allowing the tailgating vehicle unauthorized entry while the gate is reversing back to the open position. If switch 2 is turned ON (Stop), the closing gate that gets activated by a tailgating vehicle will stop, partially or completely blocking the pathway, NOT allowing the tailgating vehicle to enter without proper authorization. The gate will not move until all sensors are clear, usually forcing the tailgating vehicle that activated the sensors to back away from the gate. The gate will then continue until closed, helping prevent the tailgating vehicle from unauthorized entry. SW 2 Switch 3 Switch must be in the OFF position. Inputs connected to terminal #5 will open and reverse the gate only 14 Ft. SW 2 Switch 4 This switch determines the operation of the built-in solenoid lock. The OFF setting is the factory setup. Caution: Do not set this switch to ON unless the 2600-862 fail-secure manual release kit has been installed in the operator. Changing this switch to the ON setting without installing the lock kit will damage the operator. See pages 36 and 37 for more information about Fail-Safe vs. Fail-Secure release systems. SW 2 Switch 6 Turning the quick-close feature on will cause the auto-close timer to close the gate after 1 second, regardless of the setting of the auto-close timer potentiometer. This will also cause an opening gate to stop and reverse when the reverse loops and/or photo sensors are cleared. This feature, along with turning SW 2, switch 2 ON above, is useful to help prevent tailgating vehicles from unauthorized entry. SW 2 Switches 7-8 These work in conjunction with each other and determine if the operator will stop the gate at the full close position, or if the gate should stop 1, 2 or 3 inches short of the full close position. Needed only when using a reversing edge entrapment protection device on the closing edge of the gate with an end post as the physical stop. 9100-065-Z-3-13 23 3.3 Automatic Open / Close Limit Adjustment The 9100’s open/close limits DO NOT have to be physically adjusted. Every time the 9100 is powered up, the first open command will automatically run “Multiple gate cycles” that will locate and remember the gate’s open and close positions. These positions are determined by the physical stops that have been installed (See section 1.2, page 10). Timer: The Auto-Close Timer should be turned ON (SW 1, switch 2) to allow the “multiple gate cycles” to run automatically, otherwise manual close commands will be required to complete this sequence. Clutch: The clutch’s factory setting will work correctly for most installations. The clutch must NOT slip while the gate is cycling between the full open and full closed position or the gate limits will be incorrect. If the clutch slips during this period, it must be tightened before running this sequence (See section 3.4 on the next page). Safety Devices: Run this sequence before testing any safety features (primary inherent reverse sensor, secondary entrapment protection, entrapment alarm and reset features). Reversing Edge mounted on the Gate using End Posts: When using a reversing edge on either end of the gate with an end post as the physical stop, the reversing edge must be disconnected from the circuit board everytime this sequence will be run (the UL 325 terminal can be unplugged from the circuit board). Sequence of Automatic “Multiple Gate Cycles” to Set Gate Limits CAUTION: Keep pedestrians and vehicles clear of the gate while this sequence is running! After the first open command is given to the operator (gate can be in any position): “Multiple Gate Cycles” Open Gate MUST open until it contacts the physical “open” stop. (if gate starts to close, turn power off and change the direction operator opens (SW 1, switch 1). Turn power back on and give open command again). Close Auto-close timer will close the gate until it contacts the physical “close” stop. (Manual close command required if timer is turned off). Open Gate will automatically open until it gets approximately 12 inches away from the full open position and stop, then continue opening until it contacts the physical “open” stop again. Auto-close timer will close the gate until it gets approximately 12 inches away from the full close position Close and stop, then continue closing until it contacts the physical “close” stop again. (Manual close command required if timer is turned off). Sequence Finished Open and close gate positions are now set and will be remembered by the 9100 (until it loses AC power). Gate will function normally after automatic “Multiple Gate Cycles” sequence has finished. Note: If gate encounters an obstruction during this sequencing, it will automatically continue after obstruction has been cleared. 24 9100-065-Z-3-13 3.4 Clutch Adjustment In addition to the inherent reverse sensor, this operator is equipped with a mechanical slip clutch (UL 325 Type C) to further reduce the possibility of injury should an entrapment occur. DO NOT over tighten the clutch to compensate for a gate that is damaged, poorly constructed or too heavy. Over tightening the clutch would create a hazard which could result in serious injury or death to persons who may become entrapped. Ideal Clutch Adjustment: The operator will cycle the gate without the clutch slipping. The clutch will slip and the gate will reverse ONLY after striking an obstruction with no more than 75 Lbs of force. This force can be measured with a gate scale, DoorKing P/N 2600-225. To adjust clutch: 1 Make sure power to operator is OFF when adjusting clutch. 2 Hold large pulley to loosen the hex bolt counter clockwise. 3 Magnetic spring assembly can now be loosened (counter clockwise) or tightened (clockwise) to adjust the clutch. 4 Tighten the hex bolt to lock assembly after adjustment. Note: After power has been turned back on, the first open command will automatically run the “multiple gate cycles” to locate and remember the open and close gate positions (See section 3.4 on previous page). Hex Bolt Test the operator clutch adjustment: Magnetic Spring Assembly Hex nut is connected to black plastic magnet holder. Important Note: 2 magnetic sensors located on the bottom of the circuit board sense when the magnetic spring assembly is slipping during operation. Keep all high voltage wires away from the 2 sensors to avoid any electrical interference between the sensors and magnets. CAUTION: Keep pedestrians and vehicles clear of the gate while testing clutch! Place an immobile object along the gate path, allowing the gate to strike it while in the open and close cycles. The clutch must slip and the gate must reverse direction after striking the object. If it does not, readjust the clutch. Repeat this test until the correct clutch adjustment has been achieved. The operator will assume a soft shutdown after striking and reversing the gate which will require a key switch command to cycle operator again. 3.5 Inherent Reverse Sensor Adjustment This vehicular gate operator is equipped with an inherent adjustable reversing sensor (Type A) used as the primary entrapment protection system according to UL 325 standards. The gate will reverse direction after “physically” encountering an obstruction in either the opening or closing gate cycle. If the Auto-Close Timer (DIP-switch SW 1, switch 2) is ON and the gate physically encounters an obstruction during the CLOSING cycle, it will reverse to the open position and HOLD the gate at this position (Soft shutdown condition). Another input command is needed before the gate will reset and close again. If the Partial Open Feature is being used and the gate physically encounters an obstruction during the CLOSING cycle, the gate will only reverse to the FULL open position and NOT the partial open position. For the reverse system to function correctly, the gate must be properly installed and work freely in both directions. The clutch must be properly adjusted before adjusting the reverse sensor. Min Max Sensitivity Key Switch 1 Press the Key Switch button to cycle the gate. 2 While gate is cycling, slowly rotate reverse sensor clockwise until the gate reverses direction. Rotate reverse sensor back counter-clockwise approximately 1/8 turn. 3 Cycle the gate a few times to be sure that it cycles completely. Reverse Sensitivity Note: Each operator must be individually adjusted if dual operators have been installed. Test the operator reversing sensitivity: Place an immobile object along the gate path, allowing the gate to strike it while in the open and close cycles. The gate must reverse direction after striking the object. If it does not, increase the reverse sensitivity (step 2 ) and repeat this test until the correct sensitivity has been set. The operator will assume a soft shutdown after striking and reversing the gate which will require a key switch command to cycle operator again. 9100-065-Z-3-13 25 SECTION 4 - ENTRAPMENT AND SAFETY PROTECTION Secondary Entrapment Protection Devices: In addition to the inherent reversing sensor system, the Model 9100 has a 5-pin UL 325 terminal for the connection of photo sensors-Type B1 and reversing edges-Type B2 secondary entrapment protection devices required by UL 325 standards. Entrapment protection devices must be installed to reduce the risk of injury. Install these devices where the risk of entrapment or obstruction exists while the gate is moving. The Model 9100 offers numerous options to meet your specific needs. The next 2 pages show wiring and typical positioning of the entrapment protection devices but specific installations will vary. 115 VAC Convenience Outlets 4.1 UL 325 Terminal Description 1 2 3 4 5 REVERSE LOOP EXIT LOOP KEY SWITCH OPEN TIMER WA RN IN 6 7 8 9 ON SW2 REVERSE SENSITIVITY Note: The 5-pin terminal can be unplugged from circuit board for easy wire connections. OPEN Entrapment Sensor CLA SS R MO DE GA TE L SER OP 5338 2 ER HP IAL VO E AT OR RS REVE LOOP LTS AM PS MA X GA TE Doo PH AS LO AD rKi ng, Inc ., 60 Ing E Hz lew ood , CA H ITC G KIN OR 0 DO02-01 46 CLOSE Entrapment Sensor OPEN Contact Sensor EN OP ER TIM EXIT LOOP SW KEY 1 2 3 4 5 E VIT VERS ITI RENS SE Y 2 SW ON SW1 1 2 3 4 5 VE HI tion in n to pat not stan e. s. sigh h whi play t d in le in gat gat Rea gat e are e is e pat d own mo h a er’s ving or wal ma . k thro nua l and ugh safe ty inst ruc tion s. ON NC NO CO NF AN OR SI/ MS UL TO -32 CER 5 N/C TIF SA IED C22 TO .2 NO CU . 247 LA CA Secondary Entrapment Protection Device Connection ON 13 14 15 16 17 18 5-Pin UL 325 Terminal DOORKING 4602-010 10 11 12 G MO SE VING RI OU GA Ope S IN TE and rate JU CAN free gate RY CA of onl Do OR US peo y whe ple or not allo DE E andn gat ope AT rate w chil obs e are H truc a is Do gat dre SW 1 NC NO CLOSE Contact Sensor Low Voltage Common All inputs are normally open (NO). 1 OPEN Entrapment Sensor (Photo Sensor): Obstructed opening-direction photo beam will stop the gate during the opening-direction only. Gate will resume the open cycle when the obstructed photo beam has been cleared. Wall / Fence Closed Gate Opening-Direction Photo Beam Entrapment Area Entrapment Area 2 CLOSE Entrapment Sensor (Photo Sensor): Obstructed closing-direction photo beam will stop the gate during the closing-direction only. Gate will resume the close cycle when the obstructed photo beam has been cleared. Closing-Direction Photo Beam Wall / Fence Closed Gate 3 OPEN Contact Sensor (Reversing Edge(s)): Obstructed opening-direction reversing edge(s) will stop, then reverse the gate to the close position during the opening-direction only. Wall / Fence Filler Post if necessary • After the gate reverses to the full close position, any Closed Gate opening input will cycle the gate again. Note: If the gate is Opening-Direction Reversing Edges opening by a time clock and an opening-direction reversing Gate Support Post if Installed Entrapment Area edge gets obstructed, the gate will return to the closed position and another input (automatic exit loop, reverse loop. etc.) is needed to cycle the gate open again. • When the opening-direction reversing edge(s) gets obstructed and the gate is traveling back to the close position and the closing-direction reversing edge gets obstructed, the gate will stop and enter a soft shutdown condition (See page 32). 4 CLOSE Contact Sensor (Reversing Edge): Obstructed closing-direction reversing edge will stop, then reverse the gate to the open position, during the Entrapment Area closing-direction only. Closing-Direction Reverse Edge Wall / Fence • After the gate reverses to the open position, the timer will Closed Gate automatically close the gate (if it is turned on). If the closing-direction reverse edge is activated a second time prior to the gate reaching the close position, the operator will stop and enter a soft shutdown condition (See page 32). • When the closing-direction reversing edge gets obstructed and the gate is traveling back to the open position and the opening-direction revering edge gets obstructed, the gate will stop and enter a soft shutdown condition (See page 32). 5 26 Low Voltage Common: Common terminal for all the secondary entrapment protection device inputs. 9100-065-Z-3-13 4.2 Secondary Entrapment Protection Device Locations Typical UL Photo Sensor mounting height and distance away from gate. If the distance between the gate and wall is greater than 2 1/4”. Secure Side Non-Secure Side Inside Property Outside Property 5” or Less 5” or Less Reversing Edge (Open Contact Sensor) Gate Frame UL sensor mounted on wall. Gate Frame UL sensor mounted on post. Note: Additional photo sensors can be added above the 27.5” height. Filler Post or Barrier Wall No higher than 27.5” above grade. 21” is typical for most installations. Photo sensors may be installed on either side of gate frame, as close as practical to the gate but no further away than 5”. A filler post or barrier may need to be installed between the gate and wall area to reduce the distance to 2 1/4” or less. A reversing edge should be installed on the post or barrier for safety (See page 4 for more information). Photo Sensors (With Filler Post and Reverse Edge) Sample Setup Closing-Direction Photo Beam Wall Filler Post with Opening-Direction Reversing Edge (If necessary, see above) Closed Gate Opening-Direction Photo Beam Closing-direction photo sensors wired to UL 325 terminal. “Reverse” Closing-Direction Option ON Normally Open 1 2 3 4 5 6 7 8 SW 2, switch 2 must be OFF. SW 2 Common 9100-065-Z-3-13 1 2 3 4 5 EXIT LOOP 5-Pin UL 325 Terminal Wiring Normally Open 6 Normally Open 7 8 9 10 11 12 13 14 15 16 17 18 Normally Open Common 1 2 3 4 5 ON IF the closing-direction photo sensor is wired to the #6 main terminal, a closing-direction photo beam that gets obstructed will REVERSE the gate back to the open position. See pages 30 and 31 for more information. Main Terminal 4602 NC NO 1 2 3 4 5 OPEN Entrapment Sensor CLOSE Entrapment Sensor OPEN Contact Sensor CLOSE Contact Sensor Low Voltage Common IF the closing-direction photo sensor is wired to the UL 325 terminal, a closing-direction photo beam that gets obstructed will STOP the gate, then resume closing the gate when the obstructed photo beam has been cleared. SW1 Photo Sensor Power Note: Photo sensors can be powered by the built-in convenience outlets located on the operator (See previous page). 27 Wireless Reverse Edge Sample Setup - Single Receiver 9 V battery operated transmitter mounted on gate. Edge Transmitter Normally Open Filler Post Note: Install reversing edges on all the gate support posts or filler post in this area (e.g. cantilever gate installations, See below). Normally Open Common Wall Filler Post (If necessary) Opening-Direction Reversing Edge (If filler post is used). Closed Gate Opening-Direction Reversing Edge ClosingDirection Reversing Edge 5-Pin UL 325 Terminal Wiring Antenna mounted outside operator cover. 1 2 3 4 5 Normally Open Install Jumper Wire Normally Open Coax Antenna Kit P/N 1514-073 Common 24 VAC Receiver Place receiver in operator. Com 1 2 24 Volt 4 5 Main Terminal Wireless Note: Refer to the instruction sheet that comes with the receiver/transmitter for more specific wiring and mounting instructions. CLOSE Entrapment Sensor OPEN Contact Sensor CLOSE Contact Sensor Low Voltage Common When either direction reversing edge gets obstructed, the gate will STOP and reverse direction. EXIT LOOP 3 Power is limited to 250 mamps. OPEN Entrapment Sensor 6 7 8 9 10 11 12 ON 13 14 15 4602 16 17 18 NC NO SW1 Photo Sensor and Wireless Reverse Edge Sample Setup ClosingDirection Reversing Edge Install Opening-Direction reverse edges on the gate support post(s) in this area. Cantilever Gate Opening-Direction Photo Beam Com 24 Volt Antenna mounted outside operator Wireless Note: Refer to the cover. Power is limited to 250 mamps. 2 4 5 Place receiver in operator. Main Terminal 16 17 18 Photo Sensor Power Note: Photo sensors can be powered by the built-in convenience outlets located on the operator (See page 24). 5-Pin UL 325 Terminal Wiring Normally Open Common Com 1 2 3 4 5 OPEN Entrapment Sensor CLOSE Entrapment Sensor OPEN Contact Sensor CLOSE Contact Sensor Low Voltage Common ON 13 14 15 24 VAC Receiver EXIT LOOP 3 10 11 12 Coax Antenna Kit P/N 1514-073 28 1 6 7 8 9 instruction sheet that comes with the receiver/transmitter for more specific wiring and mounting instructions. Normally Open Edge Transmitter 9 V battery operated transmitter mounted on gate. 4602 NC NO SW1 When a reversing edge gets obstructed, the gate will STOP and reverse direction. When a photo beam gets obstructed the gate will Normally Open STOP, then continue in the same direction Common after obstructed photo beam has been cleared until the gate cycle is complete. 9100-065-Z-3-13 4.3 Loop Detector Wiring To help protect the operator from accidentally closing on vehicles in the gate’s path, DoorKing highly recommends that loops and loop detectors be installed. Loops are laid underneath, cut into asphalt or concrete driveways or buried beneath gravel and earth driveways. A loop detection system will sense a vehicle like a metal detector and send a signal to the gate operator preventing the gate from automatically opening or closing on a vehicle when it is in the gate’s path. DoorKing recommends that a licensed installer perform this work. DoorKing offers a free “Loop and Reverse Loops Loop-Detectors Information Reverse loops are placed on each Manual” PDF located at side of the gate to prevent the gate from Doorking’s web site for more closing on a vehicle in the gate’s path. They will information. www.dkaccess.com reverse OR stop the cycling of the gate while a vehicle is in or near the gate’s pathway. re Note: See page 23, SW 2, switch 2 for reverse loop options. ad ire W Lo In op W Le ire s ad In SW 2 s a m to Au LOOP 1 ON 1 2 3 4 5 6 7 8 Reverse loop lead-in wires are twisted approx. 6 twists per foot and are wired in series. te . e ga e d nc rs oi re ve av fe te . o er Re ga e . t nt d nc in t i oi re n av fe .m e o er Ft em 4 v . t nt o in t i m n .m e e. e Ft m e nc 4 v rs d re o oi fe m ve av er Re o nt .t i in op o it .m l Ex Ft se c 4 ver ti PVC Conduit A op Le Automatic Exit Loop DoorKing Plug-in Loop Detectors Lo Automatically opens the gate for exiting vehicles without having to use a transmitter or keypad. The exit loop can be placed a minimum of 4 feet away from the reverse loop or far enough away from the gate so the gate has started or completely opened by the time you drive up to it (Free exit). A B Single Channel 9410 Single Channel 9410 PVC Conduit SW 2 SW 2, switch 1 must be ON to fully open gate (Normal function). Note: The plug-in exit loop detector can be wired to partially open gate 14-Ft. if SW 2, switch 1 is turned OFF. A jumper wire must be connected from terminal #10 to terminal #5 (See next page for more information). Partial Open LOOP 1 ON Exit loop lead-in wires are twisted approx. 6 twists per foot. 1 2 3 4 5 6 7 8 B REVERSE LOOP EXIT LOOP KEY SWITCH OPEN TIMER 6 7 8 9 DOORKING 4602-010 10 11 12 1 2 3 4 5 13 14 15 16 17 18 NC NO ON 9100-065-Z-3-13 2 3 4 5 ON Note: Loop detector wiring is shown for DoorKing plug-in loop detector P/N 9410-010 (Single Channel) only. If other loop detectors are used, refer to the installation instructions supplied with those detectors for wiring and separate power instructions. 1 SW1 SW2 REVERSE SENSITIVITY 29 SECTION 5 - WIRING 5.1 Main Terminal Description 4 2 3 4 5 Full Open ON Partial Open 6 Standard Reverse or Stop Not Used ON 3-Button Full Open (DoorKing 3-Button station ONLY) 3-Button Close (DoorKing 3-Button station ONLY) Exit Loop Logic Output 10 (DoorKing Loop Detectors ONLY) SW 2 ON • lf SW 2, switch 1 is OFF, the normal exit loop port function is bypassed and a jumper wire is needed to open and close gate(s) for certain applications: 1 2 3 4 5 6 7 8 • lf SW 2, switch 1 is ON, the plug-in exit loop detector (Single channel) will FULLY open the gate (Normal Setting). Single operator use ONLY. Alarm Reset Entrapment Alarm Gate Tracker - Busy SW 2 - Terminal #10 connected to terminal #5 will PARTIALLY open plug-in exit loop detector (Single channel) for a single operator. - Terminal #10 connected to terminal #4 will FULLY open bi-parting gates. Dual operators ONLY using DoorKing’s plug-in DUAL channel loop detector. (Page 33). Gate Tracker - Data Dry Relay Contact Dry Relay Contact ON 1 2 3 4 5 6 7 8 15 LED Indicator Output Low Voltage Common KEY SWITCH 6 7 8 9 10 11 12 13 14 15 16 17 18 4602 NC NO N C O N Operation of relay is dependent on setting of SW 1, switches 4 and 5. Relay contacts can be set for Normally Open (NO) or Normally Closed (NC) operation. Contact rating is 1 amp maximum at 24-volts DC. Full Open 24 VAC - 250 mamp max. SW 1 1 2 3 4 5 6 7 8 • When gate is closing: input will stop gate when SW 2, switch 2 is ON. • When gate is closing: input will reverse gate when SW 2, switch 2 is OFF. 1 2 3 4 5 6 7 8 • When gate is open: auto close timer SW 1, switch 2 is turned ON, input will re-set and hold timer. • When gate is open: auto close timer SW 1, switch 2 is turned OFF, input will prevent gate from closing. 1 ON 5 SW 2 • This input ONLY fuctions when gate is fully opened or in the closing cycle. Low Voltage Common Jumper Wire SW 2, switch 2 OFF (Exit Loop Partial Open) Jumper Wire SW 2, switch 2 OFF (Dual Operators only) SW 1 1 2 3 4 5 6 7 8 For long gate application. SW 2, switch 3 must be OFF. Same operation as #4 terminal above but will only open a closed gate 14-Ft. or reverse a closing gate to the 14-Ft. open position. ON 1 2 3 4 5 6 7 8 • When gate is closed, this input will fully open gate. • When gate is open and auto close timer SW 1, switch 2 is turned ON, input will re-set and hold timer. • When gate is open and auto close timer SW 1, switch 2 is turned OFF, input will close gate. • When gate is closing, input will reverse gate. ON 1 2 3 4 5 6 7 8 Provides 24 VDC, 250 ma. maximum to power LED. Operation of LED is dependent on setting of SW 1, switches 4 and 5 (See page 22). SW 1 17 SW 1 30 9100-065-Z-3-13 5.2 Control Wiring for Single/Primary Operator Important: Controls intended for user activation must be located at least six (6) feet away from any moving part of the gate and where the user is prevented from reaching over, under, around or through the gate to operate the controls. Emergency access controls only accessible by authorized personnel (e.g., fire, police, EMS) may be placed at any location in the line-of-sight of the gate. Relay - #2 - Fully opens gate. #5 - Opens gate 14-feet. Com 3-Wire Radio Receiver 24 volt 24 Volt - 250 mamp. max. 250 mamp. max. Relay N.O. - #2 - Fully opens gate. #5 - Opens gate 14-feet. 4-Wire Receiver Relay Com WA R NIN MO SE VIN RIO G US SS MO LAR 24 Volt Com TE 53382 247 GAT DEL SER IAL Com GA Ope INJ CA and rate UR N free gate Y ORCA of only Do peop whe US or not allow le DE E andn gate oper AT obst area ate child H Do gate ren ruct is ions in sigh pathnot stan . to play . whil d t in in e gate gate gate Read area is path own mov er’s ing.or walk man thro ual ugh and safe ty instr uctio ns. CON FOR MS TO ANS I/ CAN CER /CS TIFI A C22ED VEH TO ICU .2 NO. CLA G E OP ERA TOR HP VOL TS E ERS REVP LOO AMP S MAX GAT E LOA Doo D rKin g, Inc. PHA SE 60 Hz , Ingl ewo od, CA N OPEER TIM T EXI P LOO ITCH SW KEY G KIN OR 10 DO 2-0 460 ON SW SW Fire Box 1 E ERS TY REVSITIVI SEN ON 1 2 3 4 5 2 1 NC NO 2 3 4 5 #2-Fully opens gate. #4-Connected device fully opens gate. #5-Connected device opens gate 14-feet. Green Close White Com 3-Button Control Station DoorKing ONLY Key Switch ON Setting - Stops gate then continues closing when gate is clear (Same function SW 2 as UL 325 terminal #2). Note: The ON setting is used to help prevent tailgating but the photo sensor should be wired to the UL 325 terminal #2 when the “stop gate” function is desired, see page 27 for more information. 16 17 18 4602 NC NO Com #5 Terminal Note (Single Operator Only): Any opening device connected to terminal #5 will open the gate to the partial open 14-ft setting. Secondary entrapment protection devices will also open the gate to the partial open setting. If the Inherent Reverse Sensor gets activated during the close cycle, it will always fully open the gate. ON 9100-065-Z-3-13 13 14 15 1 2 3 4 5 6 7 8 Note: All stand-alone and telephone entry devices must use a separate power source. ON Stand-Alone Card Reader OFF Setting - REVERSES GATE. 1 2 3 4 5 6 7 8 Stand-Alone Keypad Partial Open 10 11 12 “Optional” REVERSE GATE for Closing Direction Photo Sensors Functions ONLY during gate closing cycle. SW 2, switch 2: After photo sensor beam gets obstructed: KEY SWITCH Full Open 6 7 8 9 Red Full Open Telephone Entry Full Open SW 2, switch 3 must be OFF. SW 2 31 5.3 Auxiliary Device Wiring Blue Alarm Reset Terminal Red Alarm Output Terminal White Common Terminal Remote Alarm Reset Station (DoorKing P/N 1404-080 Only) MUST be located in the line-of-sight of the gate and no further than 50 feet from the gate. 1 2 3 4 5 EXIT LOOP KEY SWITCH 6 7 8 9 10 11 12 Gate Tracker (Quad Box Shown) DoorKing Access Control System (Model 1833, 1835, 1837 or 1838) tracker system can be connected.This system can keep track of gate operator cycle count, shorted inputs, loop detector problems, any forced entry attempts, if the gate has struck anything during the open or close cycle, power interruptions, etc. For more detailed information refer to the Tracker Installation and Wiring Manual, DoorKing P/N 2351-010. 16 17 18 ON 13 14 15 4602 NC NO SW1 Terminal #4 (Full open) or #5 (14-Ft. open) required only if the tracker board will activate the gate operator. Refer to the manual 2351-065 for detailed information. 32 9100-065-Z-3-13 5.4 Bi-Parting Gates Wiring - Dual Gate Operators • Separate power source for photo sensors (See page 26). Secondary Entrapment Protection Devices for Bi-Parting Gates Closing Non-Contact Sensor To Close Photo #2 Fence Filler Post if necessary (See page 4 for more information). Opening Non-Contact Sensor Opening Contact Sensor Gate To Close Photo #2 Fence Opening Contact Sensor Filler Post if necessary (See page 4 for more information). Gate Opening Non-Contact Sensor Primary Operator Secondary Operator To Common #5 To Common #5 To Open Edge #3 To Open Edge #3 To Close Photo #2 To Open Photo #1 To Open Photo #1 • Requires AC power to each operator. Com Relay 24 Volt 250 mamp. max. • Both operator DIP-switches must to be set. • Connect all control devices, auxiliary devices and loops to the primary operator only. ON 1 2 3 4 5 6 7 8 2 3 4 5 Yellow When using Dual Channel plug-in loop detector. Connect #4 to #10: fully opens gates. Purple Brown N.O. Jumper Wire SW 2, switch 1 SW 2 must be OFF. Loop Detectors Close Edge Common Orange Com Purple Brown 1 2 3 4 5 UL 325 Terminal 16 17 18 Blue Close Edge Common Orange Gray 6 7 8 9 133 14 15 4602 Gray EXIT LOOP KEY SW SWITCH W 10 111Open Photo Close Photo 122Open Edge Green to Green to primary secondary operator operator chassis SW1 chassis ground. ground. NC NO 2 3 4 5 16 17 18 1 2 3 4 5 UL 325 Terminal NC NO ON Automatic Exit Loop 10 111Open Photo Close Photo 122Open Edge Yellow ON Reverse loop lead-in wires are wired in series. 6 7 8 9 133 14 15 Loop Lead-In Wires Reverse Loop KEY EY SWI SWITCH SW WI Red to Close Photo #2 Reverse Loop EXIT LOOP Red to Close Photo #2 Jumper Wire 1 Primary Operator 1 (Fully Opens Gates) 4-wire receiver wiring, see page 31. Secondary Operator 3-Wire Receiver SW1 4602 Blue Interconnection Cable Sold separately from DoorKing. 6 wires used (8 - 18 AWG wires total). Dual Channel 9409 Plug into Primary Operator Exit Loop Port 9100-065-Z-3-13 33 SECTION 6 - OPERATING INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS WARNING - To reduce the risk of injury or death: 1. READ AND FOLLOW ALL INSTRUCTIONS. 2. Never let children operate or play with gate controls. Keep the remote control away from children. 3. Always keep people and objects away from gate. NO ONE SHOULD CROSS THE PATH OF THE MOVING GATE. 4. Test the operator monthly. The gate MUST reverse on contact with a rigid object or stop or reverse when an object activates the non-contact sensors. After adjusting the force or the limit of travel, retest the gate operator. Failure to adjust and retest the gate operator properly can increase the risk of injury or death. 5. Use the emergency release only when the gate is not moving and power has been shut-off. 6. KEEP GATES PROPERLY MAINTAINED. Read the owner's manual. Have a qualified service person make repairs to gate hardware. 7. The entrance is for vehicles only. Pedestrians must use separate entrance. 8. SAVE THESE INSTRUCTIONS. 6.1 AC Power and Reset Switch Unlock the power switch cover and open to access the Main Power, and the operator Reset switch. WA R NI Important: The operator WILL NOT lose its open and close limit positions after pressing the reset button. NG MO SERVIN IO G G US ATE Op era IN an te JU CAN d fre ga RY C e ofte on Do OR AUS pe ly wh op or not all le en DEA E an ga op d ob te era ow TH te child str are Do CO NF AN OR SI/U MS L-32TO 5 RT IF A C2 IED 2.2 TO HIC ULA NO. 24 CL AS 7 R S ga uc a is te. ren tio in pa not sta to ns sig th pla . ht wh nd y in ile in ga Re ga ga te te te ad are is pa ow mo th a ne vin or wa r’s g. ma lk nu thr al ou an gh d sa fet y ins tru cti on s. CA CE N/ CS VE MOD EL SE RI AL VO LT S 533 82 GAT EO PE RAT OR HP AM PS MAX GA TE Do LO AD orKi ng , In c., In PH 60 AS E Hz glew oo d, CA RESET AC POWER OFF Reset Button - Used to turn off the entrapment alarm and to reset the operator after a HARD shutdown has occurred. Alarm Siren AC Power Switch - Powers the operator ON (toggle up) or OFF (toggle down). Every time the 9100 is powered up, the First open command will automatically run “Multiple gate cycles” that will locate and remember the gate’s open and close positions (See page 24). 34 9100-065-Z-3-13 6.2 Shutdown Conditions Under various entrapment conditions the operator will assume either a soft or hard (alarm) shutdown. To determine what type of reset action is required, you will need to understand how the different entrapment conditions affect the gate operator. Soft Shutdown This occurs in various situations where the inherent or secondary entrapment protection devices have been activated. In a soft shutdown condition, the operator will not respond to any input that was present when the entrapment protection device sensed an obstruction. If the gate stops at the open position, the operator will not respond to the automatic close timer. • Example 1 - A time clock keys the gate open in the morning and an entrapment protection device senses an obstruction prior to the gate reaching the full open position. If the entrapment is sensed by the inherent system, the gate will reverse and run back to the closed position. The time clock input is still present, but the gate will not re-open. Note: In some systems, the time clock input comes from the telephone entry system relay. This same relay may also provide open commands for a card reader, MicroPLUS transmitters and the visitor telephone entry. If so, these devices will also be disabled in a soft shutdown condition. • Example 2 - If the gate is closing and an entrapment protection device is activated, the gate will either stop or reverse and run back to the open position, depending upon if the secondary or inherent device was activated. The automatic close timer will not close the gate. • Example 3 - Vehicle arrives at exit loop and gate runs towards the open position. If the inherent entrapment protection gets activated during this opening cycle, the gate reverses and runs back to the closed position. After the inherent entrapment protection is cleared, If the vehicle is still present at the exit loop, a soft shutdown condition does not occur. The exit loop input provides an immediate reset of the operator and the gate will again run to the open position. Resetting a Soft Shutdown In some conditions, a soft shutdown will reset as soon as the entrapment condition clears. For example, if a non-contact sensor (photo cell) is sensing an obstruction, the operator will stop the gate and assume a soft shutdown condition. When the photocell clears, the operator will return to normal operation. When the operator is in a soft shutdown, activation of any "intended input" will reset the operator. An "intended input" includes any command, any standard safety input and any loop input. Activating any of these inputs will reset the gate. At that point the gate will return to normal operation. If the gate is open, the automatic close timer will then time out and close the gate. Hard Shutdown (Alarm Activated) A hard shutdown condition occurs when: (1.) The inherent entrapment protection system (Type A) gets activated TWO consecutive times before the gate completes the open or close cycle. (2.) The reversing edge (Type B2) gets activated and reverses but before the gate completes the reverse cycle the inherent entrapment protection system (Type A) gets activated. • Example of a Hard Shutdown - The gate is closing and the inherent entrapment protection system senses an obstruction and causes the gate to reverse direction. As the gate begins to run in the open direction, a second obstruction is sensed prior to the gate reaching the full open position. Once the second obstruction has been sensed, the operator will stop, the audio alarm will sound and all standard inputs are shut down (including open commands, safety commands, loop inputs, etc.). – To silence the alarm, press the reset button or after 5 minutes, the audio alarm will shut off but will “chirp” every 5 seconds. This indicates that the operator is in a hard shutdown condition (The reset button must be pressed to reset the operator and stop the alarm “chirping”). 9100-065-Z-3-13 35 Resetting a Hard Shutdown The operator is in a hard shutdown condition when the audio alarm is sounding OR “chirping” every 5 seconds. • Before resetting a hard shutdown, determine why the shutdown occurred. Inspect the gate for any obstructions along its path that could have activated the inherent entrapment sensing system. Inspect the gate and gate hardware. The audio alarm will sound for five minutes, or until the operator’s reset button is pushed. After (5) five minutes the alarm will “chirp every 5 sec.” and the hard shutdown condition will remain in affect until the reset button is pushed. Note: DoorKing operators have a built-in alarm reset push button mounted on the operator above the power ON-OFF toggle switch. Activating this button will return the gate operator to normal operation, but will not cycle the gate operator. A remote alarm/reset station (P/N 1404-080) can be mounted external of the gate operator provided that it is installed in the line-of-sight of the gate and gate operator. The gate operator WILL NOT lose its open and close positions after resetting a hard shutdown. Once the gate has been reset, an open or close command is needed to start the gate operator. Most activating commands will cause the gate operator to cycle to the open position. This includes activation of a key switch or open command and activation of an automatic exit loop. Activation of a close command will run the gate to the closed position. 6.3 Manual Gate Operation This operator is equipped with one of two types of manual release systems, “Fail-Safe” (required by many city codes) or “Fail-Secure” that will allow the gate to be pushed open in the event of a power outage or equipment failure. Caution: Never attempt to manually push open any gate with an operator attached to it until you have verified that power to the operator has been shut-off. Fail-Safe Manual Release System (Factory Installed) This manual release system is the most reliable and safest method for placing the gate operator in manual operation. It is the preferred method of emergency gate operation under worse case conditions by many Fire Chiefs and Building Inspectors and is typically used in Class I and Class II applications. This system is accessible from either side of the gate and requires NO keys, cranks or other tools to manually operate the gate. This prevents any delays for emergency vehicle access in the event of a power outage. The operator “Fails” (Loss of AC power) in a “Safe” (Manually operable) condition. Solenoid Lock Clutch Plate SW 2, switch 4 must be OFF. ON 1 2 3 4 5 6 7 8 SW 2 Solenoid lock does NOT secure the clutch plate during an AC power failure or turning AC power off. Gate can be immediately manually operated during these conditions. 36 Solenoid lock WILL retract and secure the clutch plate during normal operation ONLY if operator senses an unauthorized manual open attempt. Gate will NOT be allowed to move. 9100-065-Z-3-13 Fail-Secure Manual Release System (Owner Installed) This manual release system (Installed 2600-862 Fail-Secure Manual Release Kit) allows the gate to be manually operated ONLY after unlocking the gate operator. Power outages or turning power off WILL NOT allow gate to be manually operated without physically unlocking the gate operator with the key first. This option is typically used in Class III and Class IV applications. The gate operator “Fails” (Loss of AC power) in a “Secure” (Manually in-operable) condition. SW 2, switch 4 must be ON. Important: solenoid lock MUST be in position shown. ON 1 2 3 4 5 6 7 8 SW 2 Solenoid Clutch Plate Lock Solenoid lock does NOT allow the clutch plate to rotate when: • The AC power is on but the operator is not cycling. • The AC power is turned off. • AC power failure. Solenoid lock automatically retracts and allows clutch plate to rotate ONLY during normal gate cycling. Key Release WA R NIN G MO SE VIN RIO G GA US TE Ope INJ CA and rate UR N free gate Y ORCA of only Do peo whe US or not allow ple DE E andn gate ope AT rate child obs area H truc is Do gate CON ANSFOR I/ULMS -32TO CAN CER 5 /CS TIF A C22IED VE .2 TO HIC NO. CLA ULAR 247 SS GA TE MO OP DEL SER 5338 2 ER ATO R HP IAL VOL TS AM PS MA PHA X GAT E LOA Doo SE 60 D rKin g, Inc. ren tion in pathnot stan . to s. sigh play whil d t in in e gate gate gate Rea d own area is path mov er’s ing.or walk man thro ual ugh and safe ty inst ruct ions . Hz Turning key 1/2 turn retracts solenoid lock and allows clutch plate to rotate for manual operation with or without AC power. , Ingl ewo od, CA Operator Housing Clutch Plate Emergency Vehicle Access Conditions This automatic vehicular gate system is designed to allow access to emergency vehicles under different operating conditions. 1. During normal AC powered operation, emergency vehicles access the gate by a separate emergency access device individually installed and wired to your gate system. The type of devices that can be used in your community depends on your city codes. These devices may include (but are not limited to) Fire Department lock boxes, Click-2-Enter radio receivers, strobe light sensors, siren sensors, etc. 2. In the event of an AC power failure, the emergency vehicle access device will not function because the gate operator is un-powered. “Fail-Safe” or “Fail-Secure” release systems for the 9100 allow the gate to be manually operated during AC power failure. ONLY the “Fail-Safe” release system allows the gate to be manually operated without unlocking the operator first and has been designed that way to allow emergency personnel to immediately manually operate the gate from either side under emergency situations. 9100-065-Z-3-13 37 SECTION 7 - MAINTENANCE AND TROUBLESHOOTING Inspection and service of this gate operator by a qualified technician should be performed anytime a malfunction is observed or suspected. High cycle usage may require more frequent service checks. T NO tch DO e clu ov e. rem plat 7.1 Maintenance When servicing the gate operator, always check any secondary (external) reversing devices (loops, photocells, etc.) for proper operation. If external reversing devices cannot be made operable, do not place this operator in service until the malfunction can be identified and corrected. Align clutch plate holes with screws to repair solenoid lock. Always check the inherent reversing system when performing any maintenance. If the inherent reversing system cannot be made operable, remove this operator from service until the cause of the malfunction is identified and corrected. Keeping this operator in service when the inherent reversing system is malfunctioning creates a hazard for persons which can result in serious injury or death should they become entrapped in the gate. When servicing this gate operator, always turn power OFF!! Operator Component 38 Pu Rem lley ove Ass em b ly Every time the 9100 is powered up, the First open command will automatically run “Multiple gate cycles” that will locate and remember the gate’s open and close positions (See page 24). Monthly Interval Maintenance Alarm Activate the primary (inherent) reverse system by blocking the gate with a solid object. When the gate reverses, block the gate in the opposite direction prior to the limit being reached. The entrapment alarm should activate. Press the reset button to silence the alarm. Drive Belt Check for alignment, tightness and wear. Chain Check for sagging. Tighten if necessary. Clutch Check for proper slippage when an obstruction is encountered. Fire Dept. Check emergency vehicle access device for proper operation. Gate Inspect for damage. Check gate wheels. rollers and guides for wear and grease if necessary. Grease Wheels and guide rollers if necessary. Loop(s) Check vehicular exit and reverse loops for proper operation. Primary Reverse System Check that the gate reverses on contact with an object in both the opening and closing cycles. Adjust the reversing sensor and/or clutch if necessary. Pulleys Check for alignment. Check setscrews. Release Check manual release for proper operation. Secondary Reverse Device Check secondary (external) reverse device(s) stop or reverse the gate when activated. Complete System Complete check of gate and gate operating system. 3 6 12 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ 9100-065-Z-3-13 7.2 Troubleshooting Have a good VOM meter to check voltages and continuity. A Meg-Ohm meter capable of checking up to 500 meg-ohms of resistance is necessary to properly check the integrity of the ground loops. When a malfunction occurs, isolate the problem to one of three areas: 1. the operator, 2. the loop system, 3. the keying devices. Use caution when checking high voltage terminals, motor capacitor and the motor. 1. Check the input indicator LEDs. They should only come ON when a keying device (card reader, push button, etc.) is activated. If any of the input LEDs are ON continuously, this will cause the gate operator to hold open. Disconnect the keying devices one at a time until the LED goes OFF. 2. Check any external secondary entrapment protection devices. Any short or malfunction in these devices can cause the gate operator to stop or to hold open. 3. A malfunction in a loop or loop detector can cause the gate operator to hold open, or to not detect a vehicle when it is present over the loop. Pull the loop detector circuit boards from the loop ports on the operator circuit board. If the malfunction persists, the problem is not with the loop system. For more information on trouble shooting loops and loop detectors, refer to your loop detector instruction sheet and to the DoorKing Loop and Loop Detector Information Manual. 4. Check to be sure that there are no shorted or open control wires from the keying devices to the gate operator. If a keying device fails to open the gate, press the Key Switch or momentarily jumper across terminals 4 and 18 on the operator circuit board. If the gate operator starts, this indicates that a problem exist with the keying device and is not with the gate operator. 5. If a three-button control station (open-close-stop) is connected to this gate operator, check for proper wiring. Only a DoorKing three button control station (P/N 1200-006 or 007) can be used with this gate operator. Others will cause a malfunction. 6. Check the high voltage supply. A voltage drop on the supply line (usually caused by using too small supply voltage wires) will cause the operator to malfunction. Refer to the wire size chart in section 2.1 on page 20. Note: After power has been turned back on, the first open command will automatically run the “multiple gate cycles” to locate and remember the open and close gate positions (See page 24). Symptom Operator will not run. Power LED is OFF. Operator will not run. Power LED is ON. 9100-065-Z-3-13 Possible Solution(s) • Check that AC power to the operator is turned ON. • Transformer may be overheated. Turn power off and allow board to cool for several minutes then retest. Check for low 115 VAC power and low voltage shorts. • Check for 115 VAC at high voltage terminal. If voltage measures 0, check the incoming power wires or replace the circuit board. • If a photo-cell is used as a secondary entrapment prevention device, check to be sure that the beam is not blocked. • Be sure that the chain is not too tight. A too tight chain may cause the operator to stall. • Bypass circuit board and Check Motor: Turn power switch OFF and remove the circuit board. Place a jumper wire from the 117 VAC SWITCHED terminal to the BLUE wire on the 8 pin POWER connector on the control board. CAUTION – HIGH VOLTAGE. Turn the power switch on. The motor should run. Turn the power switch OFF and remove the jumper. Place a jumper wire from the 117 VAC SWITCHED terminal to the RED wire on the 8 pin POWER connector on the control board. CAUTION – HIGH VOLTAGE. Turn the power switch on. The motor should run in the opposite direction. Turn the power switch off and remove the jumper. • If the motor runs in both steps above, replace the control board. If the motor does not run, or runs in only one direction, problem can be a bad motor, motor capacitor, motor resistors, wire connections from the control board to the motor or a bad control board. 39 Symptom Gate opens a short distance, then stops and reverses. Gate opens but will not close. Gate closes but will not open. 40 Possible Solution(s) • • • • Check that the clutch is adjusted properly and is not slipping. Disconnect the gate from the gate operator and check that the gate slides freely without any binding. Re-adjust the reverse sensitivity. Check that the magnetic pickup transistors on control board are not obstructed by excess wires. Electrical interference from excess wires can diminish magnetic field. • Check that the magnetic pickup transistors on control board are within 1/8 inch of the clear plastic protective cover above the black plastic magnetic spring assembly on the main shaft. • Continue troubleshooting or replace the circuit board. • Check the input LEDs. Any ON will hold the gate open and indicates a problem with a keying device. • Check the secondary safety devices. Any activated will hold the gate open and indicates a problem with the safety device. • Check the loop detectors. Any activated can hold the gate open and indicates a problem with the loop detector or ground loop. • Operator may be in a “soft shutdown.” Activate any keying device to determine if operator returns to normal operation. • If automatic close is desired, be sure SW 1, switch 2 is ON and set timer open from 1-23 seconds. • Bypass circuit board and check motor as described on previous page. • Operator may be in a “soft shutdown.” Check input LEDs. If any are ON, momentarily disconnect, then re-connect the wire going to the respective terminal. Operator should open. • Check to be sure that the operator is running in the proper direction. Turn power OFF, and then back ON. Activate a keying device. Operator should run in the open direction. If operator runs in the close direction, turn power OFF and change direction switch SW 1, switch 1. Go to above section if operator now opens but will not close. • Be sure that the each LED on the control board lights when the keying device connected to the that terminal is activated. If LED does not light, momentarily place a jumper wire from terminal 1 to the input terminal being checked. If LED lights and gate opens, problem is with the keying device. If LED does not light, replace control board. • Bypass circuit board and check motor as described on previous page. Gate starts to close, then reverses to open. • • • • • Check that the clutch is adjusted properly and is not slipping. Re-adjust the reverse sensitivity. Disconnect the gate from the gate operator and check that the gate slides freely without any binding. Check the loop detector LEDs and input LEDs. Any that flash ON will cause the gate to reverse. Check the Magnetic Sensor LEDs on the circuit board. If either LED is not blinking as the operator is running, check that the magnetic pickup transistors are within 1/8 inch of the protective plastic cover above the magnet assembly on the main shaft. • Continue troubleshooting or replace the circuit board. Gate closes then re-opens. • Check for any input or loop detector LED’s that are ON. • Check that the operator is running in the proper direction (see “gate closes but will not open”). • Check the SELF-TEST DIP switch setting, SW 1, switch 6 should be OFF. Alarm is sounding. Operator will not run. • Operator is in a “hard shutdown” condition. Reset button must be pushed to return operator to normal operation, see Section 6.2 Shutdown Conditions, pages 35-36. Alarm chirps once every 5 seconds. Operator will not run. • Operator has been in a “hard shutdown” condition in excess of 5 minutes. Reset button must be pushed to return operator to normal operation, see Section 6.2 Shutdown Conditions, pages 35-36. 9100-065-Z-3-13 7.3 Accessory Items The following accessory items are available for the model 9100 slide gate operator. Contact Sensors - For use as a secondary entrapment protection device. Miller Edge, Inc., MGO20, MGR20, MGS20 Photo Cell - Non-contact (photocell) sensors for use as a secondary entrapment protection device. MMTC, Inc. Model IR55 - P/N 8080-010 MMTC, Inc. Model 60-278 - P/N 8080-011 Carlo Gavazzi Type PMP12 - P/N 8080-030 Carlo Gavazzi Type PMT - P/N 8080-031 Loop Detector - Detectors plug directly into ports on circuit board simplifying wiring. Single channel detector - P/N 9410-010 Dual channel detector - P/N 9409-010 Loop Wire - 18 AWG loop wire with XLPE insulation is ideal for ground loops. Available in 500 and 1000 foot rolls. Red, blue or black insulation. Pre-Fab Loops - Prefabricated ground loops. 24-foot circumference with 50-foot lead-in. Available in yellow, red or blue jackets. Not for use in asphalt roadways. Loop Test Meter - Meg-ohm meter checks the integrity of ground loops. P/N 9401-045 Remote Alarm/Reset Station - Provides a remote station to reset an operator in a hard shutdown condition. Must be mounted in line-of-site of the gate and operator. Includes visual alarm light and audible siren. P/N 1404-080. 3-Button Control Station - Provides open-close-stop manual operation of the gate. Stand Alone Box - P/N 1200-006 Interior (fits in single gang box) - P/N 1200-007 Interconnect Cable - Interconnect wire cable contains all the necessary wires to interconnect primary / secondary operators. Cable length: 30 ft. - P/N 2600-755 40 ft. - P/N 2600-756 50 ft. - P/N 2600-757 Time Clock - 7 day and 365 day time clocks can be used to automatically open gate at pre-set time and days. Compact clock fits inside the operator. 7 day clock - P/N 2600-791 365 day clock - P/N 2600-795 V-Wheels - 4 inch and 6 inch. UHMW or Steel. Roller bearings or sleeve bearings. Single or tandem wheel configurations. Endless Idler Assembly with Safety Cover - Use when gate operator chain needs 180° return. P/N 2600-818 Guide Rollers with Safety Covers - A variety of sizes to support slide gates. Gate End Retainer - Fits on top of end post and helps stabilize the end of the gate in the open or closed position (End post not provided). P/N 1204-004 Base Plate for 9100 - Required for post mount installation. P/N 2600-418 Base Plate Stop Brackets for 9100 - Required for post mount installation when using chain stops. P/N 2600-970 Additional #40 Chain - 20 ft. per box. P/N 2600-442 Fail-Secure Manual Release Kit - Changes the Fail-Safe manual release to a Fail-Secure manual release. P/N 2600-862 Heater with Fan Assembly Kit - Thermostatically controlled heater and fan for cold and hot environments. P/N 1601-154 Surge Devices - High and low voltage surge suppressors help prevent circuit board failure caused by lightning strikes and power surges. High Voltage - P/N 1876-010 Low Voltage - P/N 1878-010 Gate Scale - Use to test torque required to move gate. P/N 2600-225 Speed Bumps - Prefabricated six-foot speed bump reduces traffic speed through gate system. P/N 1610-150 9100-065-Z-3-13 41 Model 9100 1/2 HP 115 VAC 1/2 HP 50uf Capacitor Blue Convenience Outlets Red Red Ground Motor Resistors White Black White Power Neutral Blue 1 Ohm 1 Ohm 30 Watt 30 Watt White Red Blue Black Purple Black MOV Assembly White HOT White 115 VAC Brown 1 2 3 4 5 REVERSE LOOP EXIT LOOP KEY SWITCH OPEN TIMER Green 6 7 8 9 Yellow Red Blue DOORKING 4602-010 10 11 12 Blue Red ON NC NO Board Ground Black ON White White 1 2 3 4 5 13 14 15 16 17 18 Built-In Solenoid Lock Brown Chassis Ground NEU SW1 Red Brown SW2 REVERSE SENSITIVITY Reset White Alarm Brown Purple AC Power 42 9100-065-Z-3-13 Installation/Owner’s Manual Model 9100 Vehicular Slide Gate Operator Use this manual for circuit board 4602-010 Revision A or higher. 9100-065-Z-3-13 www.doorking.com DoorKing, Inc. 120 Glasgow Avenue Inglewood, California 90301 U.S.A. 9100-065-N-5-10 Phone: 310-645-0023 Fax: 310-641-1586 Copyright 2009 DoorKing, Inc. All rights reserved.
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement