ACT 10 Digital Keypad
Operating & Installation Instructions
18-00001
ACT 10 Digital Keypad Operating & Installation Instructions
Installation Notes
• Always remember to factory default the controller before you start programming.
• Always remember to place the supplied Varistor across the terminals of the lock terminals to protect the relay contacts.
• Never use the onboard relay to switch AC mains voltage. An external relay isolated electrically from the ACT 10 should be used for this purpose.
• Don’t forget to change the programming code to something known only to yourself.
Important
: As with any Access Control system, always ensure there is an alternate means of escape in the event of the unit failing to operate due to power loss or in the event of fire.
Number of Users
Supply Voltage
Current Consumption
Operating Temperature
Door Open Time
Relay Contact Rating
Controller Size (H x W x D):
Controller Weight
Installation
Mounting
Output Rating
Product Specification
10 PIN Codes
12 – 24 Volts AC or DC
40mA (nominal), 120mA (maximum)
-10 to +50 degrees C
0 - 255 seconds
5A / 250Vac
138 x 87 x 37 (mm)
700 grams
Indoor or Outdoor (IP54)
Surface or Flush
100mA
ACT 10 Digital Keypad
ACT 10 Flush Kit
ACT 10 Weather Shield
Ordering Information
ACT 10
ACT 10 FK
ACT 10 WS
2
ACT 10 Digital Keypad Operating & Installation Instructions
30 Second Programming Guide
(For typical Standalone System)
1. Enter Programming Mode
On the digital keypad press button ✘ . Input the programming code (default is 9999). The LED will flash yellow / orange.
2. Change User 1 Code
On the digital keypad press button 0
, then press 1. Input the new User 1 code (4 digits)
3. Change Programming code
On the digital keypad press button 0. Press . Input the new programming code (4 digits)
4. Exit Programming Mode
On the digital keypad press button ✘ . The LED turns red and programming mode has been exited.
The ACT 10 Digital Keypad is now ready for normal use.
Note: The ACT 10 Digital Keypad may be returned to its factory default condition at any time by entering the programming mode and pressing the button three times.
For Door 2 Operation
1. Enter Programming Mode
2. Change User 2 Code
On the digital keypad: Press Button 0, then Press Button 2 (for User 2). Input the new User 2 code (4 digits)
3. Assign User 2 to Door 2
On the digital keypad: Press Button 1, then Press Button 2 (for User 2), then Press Button 2 (for
Door 2).
4. Exit Programming Mode
User 2 code will now activate Door 2 Relay.
ACT 10 Digital Keypad Programming
Press the ✘ button followed by the programming code (initially 9999). The yellow LED will flash while in programming mode. To exit the programming mode press button
✘
. Exit from programming mode occurs automatically if no key is activated for 30 seconds.
3
ACT 10 Digital Keypad Operating & Installation Instructions
Changing Codes:
Enter Programming Mode, then Press
Step Keypad Entry
1
2
3
Operation
0 Change Codes
0-9, User Number 0-9, = programming code
0000(00)-9999(99) 4 digit code – 0000 deletes User code
Example: Assign code 7529 to user 7
✘ 9999 Enter programming
0
7
7529
Change Codes
User 7
PIN code
✘ Exit programming
Default User Codes:
Programming Code: 9999(99); User 1 Code: 1234(56). All others are inactive.
Setting Switched Output Combinations:
Enter Programming Mode, then Press
Step Keypad Entry Operation Example: Assign Toggle to User 7
1
2
3
1
0-9
0-7
Set Outputs
User number 0-9,
Output function code
1
7
0
✘
✘
9999 Enter programming
Set Outputs
User 7
Door Toggle
Exit programming
Output Function Code
0
5
6
7
3
4
1
2
Door Output
Toggled
Timed
Timed
Timed
Timed
Door 2/Output 2
Timed
Timed
Timed
Timed
Output 3
Timed
Timed
Timed
Timed
Default function code is 1 (Relay Timed) for all users. When the door is toggled open, this will be indicated by the green indicator flashing.
Setting Timers:
Enter Programming Mode, then Press
Step Keypad Entry Operation
1
2
3
2
0 - 4
Set Timers
(Timer number) Buzzer sounds indicating timing. wait required period.
(Stop timing) Buzzer stops – timer set.
Timer Number Function
2
3
0
1
4
Relay time
Door 2 / Output 2 time
Output 3 time
Door Ajar time
Guest Buzzer time
Timers may be set to any duration between 2 seconds and 4 minutes.
4
Default
5s
5s
5s
30s
2s
ACT 10 Digital Keypad Operating & Installation Instructions
Setting Configuration:
Enter Programming Mode, then Press
Step Keypad Entry Operation
1
2
30-37 or 40-47
0 or 1 option number
1= Set, 0 = Unset
Option
30
Function
Door Chime
31 Silent Operation
32
33
Permanent
Backlighting
Locksaver
(Anti Tailgating)
34
35
Alarm
Keypad
Operation
Interlock
36 Six Digit Codes
37
40 Door Forced
Alarm
41 Group Disable
42
43
44
45
Auto backlighting
Door Ajar
Alarm
Fire Alarm
Override
46 Release Button
47
Twin Codes
Guest Button
Duress
Default
Off
Off
On
Off
Off
Off
Off
Off
Off
Off
Off
Off
On
Off
Off
Off
Operation
When set, whenever the door contact is opened, the built-in buzzer makes a chime sound and the buzzer output activates for 2 seconds.
When set, the keypad operates silently. No audible tones (key-presses or confirm tones) are produced from the built-in buzzer function.
When set (default), the keypad illumination is always on. This option will override option 42 (Auto backlighting)
When set, and when the relay is active (following a valid code or button release), the relay timer is truncated to 2 seconds when the door contact opens. This ensures that irrespective of programmed relay time, the door will be locked as soon as it closes, and any person following will have to enter a code.
When set, the keypad may be used as a remote keypad for an alarm system. The red and green indicators are controlled by the door contact and the release button inputs inputs respectively, and the built in buzzer is controlled by the interlock input.
When set, two or more keypads may be interlocked so that only one controlled door may be open at any one time. The interlock output is active whenever the relay is active or when the door contact is open. When the interlock input is active, the release button and all codes are inactive, the red indicator flashes.
The interlock outputs and inputs of any number of keypads may be combined on a single wire.
When set, all user codes, and the programming code, are six digits long. The default user one code becomes 123456 and the default programmer code becomes 999999.
When set, two different codes must be entered within 15 seconds in order to open the door. The outputs activated are those which have been programmed for the first code to be entered.
When set, the buzzer output is activated, if the door contact opens when a valid code has not been entered. The output is deactivated when a valid code is next entered. This is useful for monitoring fire doors etc.
When set, the top five user codes (5-9) are inactive any time the interlock input is activated. This restricts access to certain codes under external control (i.e. an alarm system output or a time clock).
When set, the keypad illumination is normally off, but will switch on in response to any key being pressed or while in programming mode. This option is overridden by option 32 (permanent backlighting). To prevent any illumination, unset options 32 and 42.
When set, and the door contact has been open for longer than the time programmed into the door ajar timer, the built–in and external buzzers sound intermittently. The buzzers may be silenced by closing the door and entering a valid code.
When set (default) and when the button on the keypad is pressed, the buzzer output is activated for the duration programmed into the guest buzzer timer.
When set, the relay is held active whenever the interlock input is active, and the green indicator will flash. This is useful for allowing a fire alarm system to override controlled doors.
When set, the interlock input activates the door 2 relay which follows output 2’s timer for Second door. This allows two doors to be controlled using one keypad.
When set, and when a duress code is entered, the door is opened normally and output 2 is activated. A duress code is any valid user code with one added to the last digit. The output will be reset when a valid user code is entered. When the duress option is set, user codes which have 9 as the last digit should be avoided as there is no corresponding duress code.
5
ACT 10 Digital Keypad Operating & Installation Instructions
Incorrect Code Lockout When three invalid codes have been entered in a row, the keypad will enter lockout mode for 20 seconds. During this time, the red LED indicator will flash and all PIN codes will be inactive.
Restoring Factory Defaults
Enter Programming Mode followed by . This restores the ACT 10 Digtal Keypad to its default settings. If the Programming Code has been forgotten, it may be set to 9999 by:
1
2.
. Remove the power from the unit.
Remove link LK1 at the back of the unit.
3 . Apply power to unit.
4 . Replace link LK1.
5 . Proceed with programming.
Note: The keypad will not operate correctly without LK1 in place.
Figure 1: Typical ACT 10 Configuration
Figure 1: Typical ACT 10 Configuration
Power up without link if
Programming Code has been lost
Shows connection for normally
DE-ENERGISED lock, (e.g. door-strike).
Door Release
Button
Door Contact
Volt - Free
Tamper Contacts
Power up without link if
Programming Code has been lost
Door Release
Button
LK1
LK1
OMR ON
5A 250VAC
5A 30V DC
OMR ON
5A250V A C
5A30V DC
N/C
0V
Interlock
OMR ON
Push
Button
Door
250VAC
5A 30V DC
OMR ON
5A250V A C
5A30V DC
0V
C
N/O
Duress
OP2
Interlock
0V
Interlock
(PB2)
Push
Button
Door
Contact
Batch: 20xx-1
Product:ACT10 Rev3.0
Serial No. 12345
0123456789
0V
Buzzer
OP3
Duress
OP2
Interlock
N/O
Batch: 20xx-1
Product:ACT10 Rev3.0
Serial No. 12345
C
N/C
N/C
C
+
-
N/O
+
-
0123456789
N/O
C
N/C
+V
DE-ENERGISED lock, (e.g. door-strike).
0V
Power Supply
12-24V ACDC
+V
Power Supply
12-24V ACDC
+V
0V
Important
!
Always Place Varistor
Across All Lock Terminals
!
+V
Across All Lock Terminals
+V
0V
Guest Buzzer
Output sink = 100mA max
12-24V ACDC
Door Release Button for Door 2
+V Power Supply
12-24V ACDC
Break Glass
Unit (optional)
Shows connection for normally energised lock, (e.g. magnetic lock).
Door Release Button
Break Glass
Unit (optional)
Door 2
6
Shows connection for normally ENERGISED lock (e.g. magnetic lock)
The ACT 10 may be used to control 2 doors as illustrated in the diagram above
220/240 Volts AC
PSU
12/24 Volts AC/DC
Tamper
ACT 10 Digital Keypad Operating & Installation Instructions
3 Outputs (100mA)
3 Inputs (100mA)
EXIT
DO silcone all screw mounting positions and cable entry.
DO NOT apply silicone to the bottom of the keypad as this will block the air vents and trap any water which may enter the keypad
If a weather shield is fitted the same applies
DO apply silicone to the top and two sides of the keypad, or shield, when used.
DO install a weather shield when the keypad is
1. installed on an uneven surface
2. in an exposed area
7
•
•
•
•
•
•
•
•
Installation Instructions for
ACT 10 Flush Mount Kit
Mount back box into wall void or aperture with wood screws provided
Ensure that the cable comes through the cable entry in the back box
Remove back plate from the ACT 10 and mount on to the removable cradle with the 3 bolts provided again bringing the cable through the rear cable entry in the back plate
Carefully remove the pluggable connector blocks on the ACT 10 and make the required connections
Replace the wired connectors in their correct positions and install the front housing of the
ACT 10 on its back plate. Any excess cable can be shoved back into the void between the cradle and the back box.
Secure the ACT 10 to its back plate with the security screw.
Fit the cradle into the back box.
Fit the front plate to the back box with the 4 security screws provided.
User List
6
7
4
5
8
9
2
3
0
1
User User Name PIN Door 1 Door 2
This manual and user list is available for download from our website, www.accesscontrol.ie
Unit C1, South City Business Centre,
Tallaght, Dublin 24, Ireland
Tel: 353-1-4662570 Fax: 353-1-4520427 UK Locall: 0845 300 5204
Web: http://www.accesscontrol.ie E-mail: [email protected]
Copyright © 2007 Access Control Technology Ltd.