Residential & VRF
Air-conditioning solutions
Every market is unique in air-conditioning
requirements. In this catalogue our customers will
be able to select the different options for residential
market and VRF solutions for Light-Commercial
market.
MINISPLIT SOLUTIONS
•
•
•
•
•
•
•
•
•
•
•
High Wall inverter
Multisplit inverter
Floor/ceiling inverter
Cassette inverter
Blower inverter
High Wall on/off
High Wall multisplit on/off
Floor/ceiling on/off
Cassette on/off
Blower on/off
Window unit
Johnson Controls wants to offer all the possible
solutions for different building design and technical
requirements, and the air-conditioning is an important
part of those global solutions.
04/05
The majority of our products are already rated as Class
A for Energy Efficiency, in order to guarantee a high
level of comfort.
According to the market necessities our customers
can find the best solution in our wide product range
depending on the building characteristics.
VRF SOLUTIONS (Outdoor units)
• Capacities from 9 to 135 kW
• Operating range of nominal power
(10% - 130 %)
• DC Inverter Scroll Technology
• Low noise levels
• High performance
• Flexible and quickly installation
VRF SOLUTIONS (Indoor units)
•
•
•
•
•
•
•
High Wall
Cassette
Convertible console floor/ceiling
Console
Blower
Fresh air
Heat recovery
york air-conditioning products
Catalogue Content
Pag.
Split Systems
High wall High Efficiency Inverter
YWHJZH 09 to 24
20
High wall Inverter
YEHJZH 09 to 24
22
High wall Inverter - NEW
YLHJZH 09 to 24
24
High wall Inverter
YJHJZH 09 to 24
26
Multi Inverter “Free Indoor Units”
YJU_YH 14 to 45
28
Floor/Ceiling Inverter
YHFJZH 12 to 60
32
Cassette Inverter
YHKJZH 12 to 60
34
Blower Inverter
YH3JZH 12 to 24 / YHEJZH 28 to 48 / YHGJZH 48 to 60
38
High wall On/Off - NEW
YKHFZH 09 to 24
40
High wall On/Off
EAHC 09 to 24 FS-R
42
Floor/Ceiling
EOHC 09 to 48 FS
46
Cassette
EKHC 12 to 48 FS
48
Blower
EUHC 12 to 60 FT
50
YV2V 010 to 135
54
VRF Systems
Amazon Standard Ambient VRF System
06/07
Cooling capacity kW
1.0
2.5 - 7.0
2.7 - 6.5
2.6 - 7.0
2.6 - 6.8
4.1 - 11.8
3.5 - 14.8
3.3 - 14.4
3.3 - 15.2
2.6 - 6.8
2.5 - 6.2
2.5 - 13.2
3.5 - 13.2
3.5 - 16.0
9 - 135
5.0
10.0
20.0
50.0
100.0
200.0
york air-conditioning products
08/09
Minisplit
Inverter Systems
high wall units
multisplits free combination
floor/ceiling, cassette & blower units
york air-conditioning products
10/11
efficient comfort
high efficiency inverter range
The High Wall inverter air conditioners have been designed thinking about comfort and sustainability. Comfort as the ultimate
technology of DC Inverter compressor installed in these units is able to achieve high performances in heating and cooling mode,
the temperature variations in the room are minimized and the noise level is lower. The active carbon electrostatic filter improves
the air quality and thanks to the motorized louver system, the air is distributed equally in the room.
Sustainable because the high efficiency of the unit results in a very low energy consumption, one of the most efficient in the
market, the materials used are recyclable and free of hazardous substances, all together makes this unit the appropriate choice
for conditioning your home.
york air-conditioning products
12/13
i n v e rt e r syst e m
h i g h e r e f f i c i e n cy a n d c o m f o rt
conventional system
inverter system
Compressor
capacity
Indoor
temperature
Desired
temperature
44%
energy
saving
energy
savings
Conventional
air conditioning
DC INVERTER
air conditioning
DC Inverter technology regulates the frequency of the compressor which results in many advantages:
• Energy saving by avoiding consumption peaks of the compressor compared to an on-off system. Inverter compressors reduce
the frequency and therefore increase the efficiency.
• The variations of the temperature in the room are reduced improving the comfort.
• The setting temperature is achieved faster thanks to the flexibility of the system which allows reaching even 30% more of
the nominal capacity.
• The overall performance is more uniform and silent.
york air-conditioning products
14/15
f i lt e r o pt i o n s
f o r a c l e a n a n d h e a lt h y a i r
STANDARD FILTER
SILVER ION FILTER
PLASMA FILTER
These filters prevent the
bigger dust particules to
enter the room by creating a
barrier against dirtyness and
insects.
The Silver ion filter kills
bacteria in the air and controls
the growth of microbes,
such as bacteria, virus, fungi,
and spores, by destroying
their inner configuration and
absorbing the cells elements.
The Plasma Dust Collector
can generate an ionization
zone. The air is converted to
plasma as it passes the high
voltage ion generator.
95% of the dust, smoke and
pollen particles are attracted
to the electrostatic filter.
DRY MOULD PROOF
Turn off the unit that contains this function when it is cooling or drying,
indoor fan would still operate in low speed to dry the inner components
and parts. This action can remain unit inside clean and dry, prevent
mould growing and olor.
CARBON
ELECTROSTATIC
FILTER
Active Carbon Filter eliminates
certain kinds of odors such
as ammonia (NH3) and
deactivates harmful chemical
gas such as formaldehyde
(HCHO).
york air-conditioning products
Range Capacities
2.0
High Wall
High Efficien.
Inverter
3.0
2.5
3.5
2.5
4.0
4.5
5.0
5.5
3.5
5.3
3.5
5.3
6.0
7.0
6.5
7.5
8.0
8.5
9.0
10.0
9.5
7.0
Page 20
2.7
High Wall
Inverter
6.5
Page 22
High Wall
Inverter
2.6
3.6
5.2
7.0
Page 24
High Wall
Inverter
2.6
3.5
5.1
6.8
Page 26
4.1
Multi
Inverter
5.1 5.3
7.4
8.5
9.7
Page 28
Floor
Ceiling
Inverter
3.5
5.0
6.5
8.3
9.3
Page 32
3.3
Cassette
Inverter
4.8
6.7
7.8
9.3
Page 34
3.3
Blower
Inverter
5.0
7.1
Page 36
High Wall
On/Off
2.6
3.4
5.1
6.8
Page 40
High Wall
On/Off
2.5
3.1
4.6
6.2
Page 42
Floor
Ceiling
2.5
3.5
5.2
7.2
Page 44
Cassette
3.5
5.3
7.0
Page 46
Blower
Page 48
3.5
5.2
7.0
8.0
9.3
kW
10.0
10.5
11.0
11.5
12.0
12.5
13.0
13.5
14.0
14.5
15.0
15.5
16.0
11.8
12.3
14.8
12.1
14.4
12.2 12.4
15.2
10.0
12.0
13.2
10.0
12.0
13.2
10.2
12.2
13.2
16.0
16.5
17.0
17.5
18.0
18.5
Minisplit Systems
16/17
york air-conditioning products
Main Features
EU Energy Label A Class
Heater Cable
With the powerful compressor and optimized
refrigerant, the SEER can reach EU Energy
Label A Class (over 5.1 w/w) or B Class (over 4.6
w/w), greatly reducing the power consumption.
Heater cable prevents ice forming on the outdoor
unit. Specially indicated in heat pump mode and
low ambient temperature conditions. A thermostat
regulates the activation of the heater.
Auto-Restart Function
Turbo Mode
When the power supply is interrupted and then
restored, the air conditioners automatically restore
the previous function setting.
Press the Turbo button and the A/C will reach the
preset temperature in the shortest time.
Two-direction Air Vane Tech
Condensate pump
With special structural design and microcomputer
control, York air conditioners employs a unique bidirectional rotary air vane technology.
Made up of a pump and a remote detection unit.
The pump absorbs the condensates from the
indoor unit and sends it to the draining pipes.
Low Ambient Kit
Dehumidification
The air conditioning unit can operate in cooling
mode at low ambient temperature conditions.
The kit is suitable for special applications such as
computer and power station control rooms where
cooling is required even in the winter months.
Independent dehumidification function is usually
used in rainy days in springtime or damps areas. The
unit will alternately operate in cooling mode or fan
only mode, which assures strong dehumidification
while not lowering room temperature.
Sleep Mode
Bio Filter
With Spleep Mode, the air conditioner’s set
temperature will automatically increase (cooling)
or decrease (heating) 1°C per hour for the first two
hours then hold steady for the next 5 hours after
which the air conditioner will stop operation. With
the sleep mode function can maintain the most
confortable temperature and save energy.
Bio Filter consists of a specialized biological
enzyme and Eco Filter. The Eco Filter catches
very small airborne dust particles and neurilities
bacteria, fungi and microbes. Biological enzyme
eliminates bacteria by dissolving their cell wall
thus eliminating the problem of re-pollution seen
in traditional air conditioners.
18/19
Minisplit Systems
Main Features
Active Carbon Electrostatic Filter
Ionizer
Active Carbon Filter eliminates certain kinds of
odors such as ammonia (NH3) and deactivates
harmful chemical gas such as formaldehyde (HCHO).
By forming positive positions on the filter surface,
Electrostatic Fiber Filter traps small dust particles,
smoke and pet fur to prevent allergic reactions.
Ionizer brings refreshing air into the home. Anions
can stimulate the blood circulation system,
improve lung function and effectively prevent
respiratory passage illnesses (sutch as asthma and
pneumonia).
Plasma Filter
Valve Protection Cover
It protects the service valves and prevents water
from dripping.
The Plasma Dust Collector can generate an
ionization zone. The air is converted to plasma as
it passes the high voltage ion generator. 95% of the
dust, smoke and pollen particles are attracted to
the electrostatic filter.
Anti-Rust Cabinet
Made from electrolytic zinc steel sheet and antirust coated components. York’s outdoor units are
rust free even in coastal regions.
Iconography
Infrared
control
Wired
control
Infrared
or Wired
control
Dry
mode
Sleep
mode
Timer
Auto
Sweep
Auto
Restart
Turbo
mode
Thin
profile
Quiet
4 Way
Air Flow
Floor/
Ceiling
Ducted
Installation
Air
Filter
Low
Ambient
Kit
york air-conditioning products
High Wall High Efficiency Inverter
YWHJZH 09 to 24
a complete range from 2.5 kW to 7.0 kW
UPDATED
VERSION
Features
Remote controller
• DC Inverter compressor
• Low noise levels
• Ultra high SEER & SCOP, class A++
• Multi louvers design for faster heating
• 1W standby
• Quiet design with low noise
• 8°C heating
• 3 sleep modes/curves
• Intelligent defrosting
• LED display
• Overlong distance air flow
• Blue crystal fin evaporator
• 7 fan speeds with turbo cooling
• 3D-airflow with auto horizontal airflow
(Left/Right)
• Low Ambient Kit
• Heater cable
• Gold fin condenser
• Service valve protection cover
• Wireless
• I FEEL function
• 5 operation modes
(Cool/Heat/Auto/Dry/Fan)
• 5 Fan speeds selection
• Quiet/sleep button
• Air flow direction setting
• LCD display
• Turbo mode
• Room temperature setting
• Lock Button Function
Minisplit Systems
20/21
High Wall High Efficiency Inverter
YWHJZH 09 to 24
Technical features
Set reference
YWHJZH
Indoor unit
Sizes
YWHJXH-09
YWHJXH-12
YWHJXH-18
YWHJXH-24
Outdoor unit
Sizes
YWHJYH-09
YWHJYH-12
YWHJYH-18
YWHJYH-24
Cooling capacity
kW
2.5 (0.7 - 3.8)
3.5 (0.7 - 4.5)
5.3 (1.0 - 6.3)
7.0 (2.0 - 8.6)
Heating capacity
kW
2.8 (0.7 - 4.0)
3.7 (0.7 - 5.5)
5.6 (1.0 - 6.8)
7.6 (1.9 - 9.0)
Compressor
Type
2.00
Rotary
Refrigerant
R410A
Power supply
Power input
V/Ph/Hz
230 / 1 / 50 + E
cooling
kW
0.65
0.90
1.51
heating
kW
0.68
0.89
1.60
2.17
3.85
3.89
3.50
3.50
EER
SEER
7.0
7.0
6.4
6.3
COP
4.01
4.08
3.50
3.50
SCOP
Energy Class
4.00
4.60
4.00
4.00
cooling
A++
A++
A++
A++
heating
A+
A++
A+
A+
Indoor airflow
m3/h
550
770
950
1 200
Sound pressure Indoor (L/M/H)
at 1 m
Outdoor
dB(A)
24 / 32 / 36
24 / 32 / 36
36 / 40 / 44
40 / 44 / 50
dB(A)
49
50
56
58
H (mm)
292
292
319
326
W (mm)
806
866
1 018
1 178
D (mm)
206
206
230
264
H (mm)
540
596
700
790
W (mm)
848
899
955
980
D (mm)
320
378
396
427
Indoor unit
kg
10.5
11
15
17.5
Outdoor unit
kg
36
43
49
69
Indoor
Dimensions
Outdoor
Net weight
Type of connection
Piping
Diameter
Refrigerant charge
Pipe run
Flare
Gas
3/8”
1/2”
1/2”
5/8”
Liquid
1/4”
1/4”
1/4”
1/4”
2 300
g
1 220
1 300
1 600
Length
m
15
20
25
25
Height
m
10
10
10
10
18
24
Operating limit - cooling mode
min./max.
-15°C / +48°C
Operating limit - heating mode
min./max.
-20°C / +24°C
Nominal cooling capacity based on : - Indoor Air Temp. 27°C DB / 19°C WB - Outdoor Air Temp. 35°C DB
Nominal heating capacity based on : - Indoor Air Temp. 21°C DB - Outdoor Air Temp. 7°C DB/6°C WB
Piping length : 5 m with initial charge
Accessories
Sizes
09
12
Electrostatic dedusting filter
Optional
Silver ion filter
Optional
Active carbon filter
Optional
Manufacturer reserves the rights to change specifications without prior notice.
york air-conditioning products
High Wall Inverter
YEHJZH 09 to 24
A complete range from 2.7 kW to 6.5 kW
Features
Remote controller
• High SEER & SCOP, Class A+
• DC Inverter compressor
• Low noise levels
• Dry mould proof
• Automatic restart
• ON/OFF timer
• Automatic air sweep
• LAK standard for sizes 9 and 12
• LAK optional for sizes 18 and 24
• Service valve protection cover
• Rustproof casing
• Blue fin protection (indoor and
outdoor units)
• Wireless
• 5 operation modes
(Cool/Heat/Auto/Dry/Fan)
• Sleep mode
• Room temperature setting
• Fan speed selection
• Timer setting function
• Air flow direction setting
• LCD display
• Turbo mode
• Lock button function
Minisplit Systems
22/23
High Wall Inverter
YEHJZH 09 to 24
Technical features
Set reference
YEHJZH
Indoor unit
Sizes
YEHJXH-09
YEHJXH-12
YEHJXH-18
YEHJXH-24
Outdoor unit
Sizes
YEHJYH-09
YEHJYH-12
YEHJYH-18
YEHJYH-24
Cooling capacity
kW
2.7 (0.5 - 3.2)
3.5 (0.5 - 3.9)
5.3 (1.3 - 6.6)
6.5 (2.5 - 6.6)
Heating capacity
kW
2.8 (0.8 - 3.6)
4.0 (0.9 - 4.4)
5.8 (1.1 - 6.8)
7.0 (2.5 - 7.6)
Compressor
Type
Rotary
Refrigerant
R410A
Power supply
V/Ph/Hz
230 / 1 / 50 + E
cooling
kW
0.87
1.17
1.62
2.18
heating
kW
0.90
1.20
1.76
2.22
EER
3.10
3.00
3.25
2.96
SEER
5.6
6.1
5.6
5.1
COP
3.11
3.33
3.30
3.15
3.8
Power input
SCOP
Energy Class
3.8
3.8
3.8
cooling
A+
A++
A+
A
heating
A
A
A
A
Indoor airflow (high speed)
m3/h
500
500
780
800
Sound pressure Indoor (L/M/H)
at 1 m
Outdoor
dB(A)
28 / 34 / 39
36 / 39 / 42
35 / 40 / 43
39 / 42 / 47
Indoor
Dimensions
Outdoor
Net weight
dB(A)
53
54
55
58
H (mm)
275
275
298
315
W (mm)
845
845
940
1 007
D (mm)
180
180
200
219
H (mm)
540
540
700
790
W (mm)
776
776
955
980
D (mm)
320
320
396
427
Indoor unit
kg
10
10
13
14
Outdoor unit
kg
28
29
45
60
Gas
3/8”
3/8”
1/2”
5/8”
Liquid
1/4”
1/4”
1/4”
1/4”
1 800
Type of connection
Piping
Diameter
Refrigerant charge
Pipe run
Flare
g
700
850
1 300
Length
m
15
15
25
25
Height
m
10
10
10
10
Operating limit - cooling mode
min./max.
Operating limit - heating mode
min./max.
-10°C / +50°C
+18°C / +50°C
-15°C / +24°C
Nominal cooling capacity based on : - Indoor Air Temp. 27°C DB / 19°C WB - Outdoor Air Temp. 35°C DB
Nominal heating capacity based on : - Indoor Air Temp. 21°C DB - Outdoor Air Temp. 7°C DB/6°C WB
Piping length : 5 m with initial charge
Accessories
Sizes
09
12
18
Electrostatic dedusting filter
Optional
Silver ion filter
Optional
Cold Plasma filter
Optional
Active carbon filter
Optional
Manufacturer reserves the rights to change specifications without prior notice.
24
york air-conditioning products
High Wall Inverter
YLHJZH 09 to 24
NEW
a complete range from 2.6 kW to 7.0 kW
Features
Remote controller
• DC Inverter compressor
• Low noise levels
• Ultra high SEER and high SCOP,
Class A++
• Dry mould proof
• Automatic restart
• Automatic air sweep
• Sleep mode function
• Self-diagnosis
• Evaporator self-cleaning
• Anti-mold filter
• Low Ambient Kit
• Service valve protection cover
• Blue fin protection (indoor and
outdoor units)
• Wireless
• 5 operation modes
(Cool/Heat/Auto/Dry/Fan)
• Sleep mode
• On/Off timer
• Turbo cool/heat settings
• Fan speed selection
• Air flow direction setting
• LED display
• Lock button
Minisplit Systems
24/25
High Wall Inverter
YLHJZH 09 to 24
Technical features
Set reference
YLHJZH
Indoor unit
Sizes
YLHJXH-09
YLHJXH-12
YLHJXH-18
YLHJXH-24
Outdoor unit
Sizes
YLHJYH-09
YLHJYH-12
YLHJYH-18
YLHJYH-24
Cooling capacity
kW
2.6 (0.9~3.2)
3.6 (1.4~3.9)
5.2 (1.5~5.6)
7.0 (2.0~7.3)
Heating capacity
kW
2.8 (1.4~3.2)
3.7 (1.4~4.1)
5.8 (1.6~6.0)
7.5 (2.5~7.8)
Compressor
Type
Rotary
Refrigerant
R410A
Power supply
V/Ph/Hz
230 / 1 / 50 + E
cooling
kW
0.71
1.00
1.53
2.18
heating
kW
0.68
0.95
1.70
2.20
EER
3.66
3.60
3.40
3.21
SEER
6.4
6.1
6.2
6.11
COP
4.12
3.89
3.41
3.41
Power input
SCOP
Energy Class
cooling
heating
4
4
4.01
4
A++
A++
A++
A++
A+
A
A
A
Indoor airflow
m3/h
450
500
900
1 200
Sound pressure Indoor (L/M/H)
at 1 m
Outdoor
dB(A)
26 / 33 / 39
27 / 34 / 40
35 / 40 / 44
37 / 43 / 47
dB(A)
51
52
53
55
H (mm)
280
280
322
336
Indoor
W (mm)
855
855
997
1 115
D (mm)
204
204
235
248
H (mm)
540
540
688
730
Outdoor
W (mm)
780
780
810
860
D (mm)
245
245
288
308
Indoor unit
kg
10
10
13
16
Outdoor unit
kg
29
31.2
43
49
Gas
3/8”
3/8”
1/2”
5/8”
Liquid
1/4”
1/4”
1/4”
3/8”
1 600
Dimensions
Net weight
Type of connection
Piping
Diameter
Refrigerant charge
Pipe run
Flare
g
900
1 200
1 300
Length
m
15
15
15
15
Height
m
10
10
10
10
18
24
Operating limit - cooling mode
min./max.
-5°C / +43°C
Operating limit - heating mode
min./max.
-15°C / +24°C
Nominal cooling capacity based on : - Indoor Air Temp. 27°C DB / 19°C WB - Outdoor Air Temp. 35°C DB
Nominal heating capacity based on : - Indoor Air Temp. 21°C DB - Outdoor Air Temp. 7°C DB/6°C WB
Piping length : 5 m with initial charge
Accessories
Sizes
09
12
Electrostatic dedusting filter
Optional
Silver ion filter
Optional
Active carbon filter
Optional
Manufacturer reserves the rights to change specifications without prior notice.
york air-conditioning products
High Wall Inverter
YJHJZH 09 to 24
a complete range from 2.6 kW to 6.8 kW
UPDATED
VERSION
Features
Remote controller
• High SEER & SCOP, Class A
• DC Inverter compressor
• Low noise levels
• Dry mould proof
• Automatic restart
• Automatic air sweep
• Sleep mode function
• Self-diagnosis
• Easy maintenance
• Service valve protection cover
• Blue fin protection (indoor and
outdoor units)
• Wireless
• 5 operation modes
(Cool/Heat/Auto/Dry/Fan)
• Sleep mode
• On/Off timer
• Turbo cool/heat settings
• Fan speed selection
• Air flow direction setting
• LED display
• Lock button
Minisplit Systems
26/27
High Wall Inverter
YJHJZH 09 to 24
Technical features
Set reference
YJHJZH
Indoor unit
Sizes
YJHJXH-09
YJHJXH-12
YJHJXH-18
YJHJXH-24
Outdoor unit
Sizes
YJHJYH-09
YJHJYH-12
YJHJYH-18
YJHJYH-24
Cooling capacity
kW
2.6 (1.3~3.0)
3.5 (1.4~3.9)
5.1 (1.5~5.5)
6.8 (2.0~7.0)
Heating capacity
kW
2.8 (1.4~3.2)
3.7 (1.4~4.1)
5.1 (1.7~6.4)
7.0 (2.5~7.6)
Compressor
Type
2.20
Rotary
Refrigerant
R410A
Power supply
Power input
V/Ph/Hz
230 / 1 / 50 + E
cooling
kW
0.83
1.16
1.70
heating
kW
0.81
1.08
1.48
2.16
3.13
3.01
3.00
3.09
EER
SEER
5.10
5.10
5.10
5.10
COP
3.46
3.43
3.45
3.24
SCOP
Energy Class
3.80
3.80
3.80
3.80
cooling
A
A
A
A
heating
A
A
A
A
Indoor airflow
m3/h
450
500
700
1 100
Sound pressure Indoor (L/M/H)
at 1 m
Outdoor
dB(A)
26 / 33 / 38
27 / 33 / 38
35 / 40 / 44
37 / 42 / 47
dB(A)
51
52
54
59
H (mm)
265
265
265
299
W (mm)
795
795
938
1 046
D (mm)
187
187
187
234
H (mm)
540
540
640
730
W (mm)
780
780
780
860
D (mm)
245
245
245
308
Indoor unit
kg
8.8
8.8
10.5
13
Outdoor unit
kg
29.5
32
35
50
Gas
3/8”
3/8”
1/2”
5/8”
Liquid
1/4”
1/4”
1/4”
3/8”
Indoor
Dimensions
Outdoor
Net weight
Type of connection
Piping
Diameter
Refrigerant charge
Pipe run
Flare
g
900
1 200
1 350
1 600
Length
m
15
15
25
25
Height
m
10
10
15
15
18
24
Operating limit - cooling mode
min./max.
+18°C / +43°C
Operating limit - heating mode
min./max.
-15°C / +24°C
Nominal cooling capacity based on : - Indoor Air Temp. 27°C DB / 19°C WB - Outdoor Air Temp. 35°C DB
Nominal heating capacity based on : - Indoor Air Temp. 21°C DB - Outdoor Air Temp. 7°C DB/6°C WB
Piping length : 5 m with initial charge
Accessories
Sizes
09
12
Electrostatic dedusting filter
Optional
Silver ion filter
Optional
Active carbon filter
Optional
Manufacturer reserves the rights to change specifications without prior notice.
york air-conditioning products
Multi Inverter Free Indoor Units
YJU_YH 014 to 045
a complete range from 4.1 kW to 11.8 kW
UPDATED
VERSION
Indoor units
Features
Remote controller
• High SEER & SCOP, Class A or more
• DC inverter compressor
• Free match indoor/outdoor
• Automatic restart
• ON/OFF timer
• Automatic air sweep
• Valve protection cover
• Single general valve design
(25K/30K/34K)
• Blue fin protection (indoor and
outdoor units)
• Same indoor units as Single Splits
• Wireless
• 5 operation modes
(Cool/Heat/Auto/Dry/Fan)
• Sleep mode
• On/Off timer
• Turbo cool/heat settings
• Fan speed selection
• Air flow direction setting
• LED display
• Lock button
Minisplit Systems
28/29
Multi Inverter Free Indoor Units
YJU_YH 014 to 045
Technical features Outdoor units
Model
Outdoor units
YJU_YH
Sizes
number
Indoor units
Cooling capacity
kW
Heating capacity
kW
Compressor
Type (Nb)
Refrigerant
Location of expansion device
Power supply
V/Ph/Hz
cooling
kW
Power input
heating
kW
EER
SEER
COP
SCOP
cooling
Energy Class
heating
Airflow (outdoor unit)
m3/h
Sound pressure level
dB(A)
Height
mm
Dimensions
Width
mm
outdoor unit
Depth
mm
Net weight outdoor unit
kg
Type of connection
Piping
Gas
Diameter
Liquid
Length
m
Max pipe run *
Height
m
Refrigerant charge
g
Operating limits cooling mode min/max
Operating limits heating mode min/max
YJU2YH014
YJU2YH018
YJU3YH019
2 indoor units
4.1 (1.2 ~ 4.5)
4.4 (1.5 ~ 5.0)
2 indoor units
5.1 (1.3 ~ 5.8)
5.8 (1.9 ~ 6.6)
3 indoor units
5.3 (1.5 ~ 7.0)
6.3 (1.8 ~ 8.1)
1.17
1.12
3.9
5.56
4.03
3.8
A
A
1 900
62
540
780
270
38
1.47
1.41
3.5
5.59
3.74
4.0
A
A+
2 900
63
688
810
288
43.5
1.39
1.52
3.8
6.6
4.30
4.0
A++
A+
2 000
52
688
886
289
51
3/8”
1/4”
30
15
1 200
3/8”
1/4”
30
15
1 400
3 x 3/8”
3 x 1/4”
50
15
2 000
YJU4YH025
* values for all the system (all indoor units connected)
Nominal cooling capacity based on : - Indoor Air Temp. 27°C DB / 19°C WB - Outdoor Air Temp. 35°C DB
Nominal heating capacity based on : - Indoor Air Temp. 21°C DB - Outdoor Air Temp. 7°C DB/6°C WB
Piping length : 5 m with initial charge (each indoor unit)
Manufacturer reserves the rights to change specifications without prior notice.
YJU4YH030
YJU5YH034
YJU5YH045
4 indoor units
4 indoor units
5 indoor units
5 indoor units
7.4 (1.5 ~ 9.0)
8.5 (1.5 ~ 9.8)
9.7 (1.5 ~ 11.0)
11.8 (1.5 ~ 13.4)
8.3 (1.8 ~ 9.5)
9.5 (1.8 ~ 10.5)
10.3 (1.8 ~ 11.5)
12.2 (1.8 ~ 14.0)
Rotary Inverter (1)
R410A
Outdoor unit
230 / 1 / 50 + E
2.10
2.41
2.94
2.94
2.06
2.43
2.85
2.85
3.5
3.5
3.3
3.09
6.6
6.6
6.6
6.6
3.80
4.00
3.90
3.80
4.0
4.0
4.0
3.8
A++
A++
A++
A++
A+
A+
A+
A
3 500
4 000
4 000
4 200
56
56
58
60
840
840
840
830
948
948
948
1 008
340
340
340
447
74
76
77
90
Flare
3 x 3/8” + 1 x 1/2” 3 x 3/8” + 1 x 1/2” 4 x 3/8” + 1 x 1/2” 3 x 3/8” + 2 x 1/2”
4 x 1/4”
4 x 1/4”
5 x 1/4”
5 x 1/4”
70
70
80
100
15
15
15
15
3 100
3 200
3 400
3 200
-10°C / +46°C
-15°C / +24°C
york air-conditioning products
Indoor units technical features
High Wall
Features
•A
ctive carbon
electrostatic filter
• Automatic air sweep
Indoor units
Cooling capacity
Heating capacity
Power supply
Indoor airflow
Sound pressure level
Dimensions
Net Weight
Piping
Sizes
07 *
kW
2.0
kW
2.2
V/Ph/Hz
m3/h
600
H/M/L
dB(A)
38 / 33 / 26
H/W/D
mm
280 / 855 / 204
kg
10
Type of connection
Gas
3/8”
Diameter
Liquid
1/4”
09 *
2.7
2.8
600
38 / 33 / 26
280 / 855 / 204
10
3/8”
1/4”
YJHMXH
12
3.6
3.7
230 / 1 / 50 + E
650
39 / 34 / 27
280 / 855 / 204
10
Flare
3/8”
1/4”
18
5.2
5.8
24
7.0
7.5
900
44 / 40 / 35
322 / 997 / 235
13
1 200
47 / 43 / 37
336 / 1115 / 248
16
1/2”
1/4”
5/8”
1/4”
Floor / Ceiling
Features
•F
loor/Ceiling
• Automatic air sweep
Indoor units
Cooling capacity
Heating capacity
Power supply
Indoor airflow
Sound pressure level
Dimensions
Net Weight
Piping
Sizes
kW
kW
V/Ph/Hz
m3/h
H/M/L
dB(A)
H/W/D
mm
kg
Type of connection
Gas
Diameter
Liquid
YHFMXH
18
5.0
5.5
230 / 1 / 50 + E
800
44 / 41 / 36
665 / 990 / 199
28.3
Flare
1/2”
1/4”
12
3.5
3.9
650
41 / 37 / 33
665 / 990 / 199
26.3
3/8”
1/4”
24
6.3
7.1
800
48 / 45 / 42
665 / 990 / 199
28.3
5/8”
3/8”
Cassette
YHKMXH
Features
•C
ondensate pump
included
• Automatic air sweep
Indoor units
Cooling capacity
Heating capacity
Power supply
Indoor airflow
Sound pressure level
Dimensions unit
Dimensions panel
Net weight
Piping
Sizes
kW
kW
V/Ph/Hz
m3/h
H/M/L
dB(A)
H/W/D
mm
H/W/D
mm
kg
Type of connection
Gas
Diameter
Liquid
09 *
2.6
2.9
620
40 / 36 / 32
260 / 570 / 570
60 / 700 / 700
17
3/8”
1/4”
12
3.5
3.7
18
5.0
5.2
230 / 1 / 50 + E
620
680
40 / 36 / 32
42 / 37 / 35
260 / 570 / 570
260 / 570 / 570
60 / 700 / 700
60 / 700 / 700
18.5
18.5
Flare
3/8”
1/2”
1/4”
1/4”
24
6.5
7.1
1 300
46 / 44 / 39
240 / 840 / 840
60 / 950 / 950
26.8
5/8”
3/8”
Slim duct
YH3MXH
Features
• Slim size
• Air filter included
•W
ired control
included
Indoor units
Cooling capacity
Heating capacity
Power supply
Indoor airflow
Static pressure
Sound pressure level
Dimensions
Net Weight
Piping
Sizes
kW
kW
V/Ph/Hz
m3/h
Pa
H/M/L
dB(A)
H/W/D
mm
kg
Type of connection
Gas
Diameter
Liquid
09 *
2.7
2.8
530
30
33 / 29 / 26
185 / 850 / 420
15.9
3/8”
1/4”
12
3.5
3.9
18
5.0
6.4
230 / 1 / 50 + E
600
900
30
30
35 / 31 / 27
36 / 30 / 26
185 / 850 / 420
185 / 1 170 / 420
15.9
25
Flare
3/8”
1/2”
1/4”
1/4”
24
7.1
7.2
1 100
30
39 / 32 / 29
185 / 1 170 / 420
27
5/8”
3/8”
Duct
YHDMXH
Features
• Air filter included
•W
ired control
included
Indoor units
Cooling capacity
Heating capacity
Power supply
Indoor airflow
Static pressure
Sound pressure level
Dimensions
Net Weight
Piping
Sizes
kW
kW
V/Ph/Hz
m3/h
Pa
H/M/L
dB(A)
H/W/D
mm
kg
Type of connection
Gas
Diameter
Liquid
* Sizes 07 & 09 only available for Multi Splits
09 *
2.5
2.9
550
25
37 / 34 / 31
220 / 610 / 483
14
3/8”
1/4”
12
3.5
4.0
18
5.0
5.5
230 / 1 / 50 + E
550
850
25
25
37 / 34 / 31
41 / 35 / 32
220 / 610 / 483
220 / 1 090 / 500
14
23
Flare
3/8”
1/2”
1/4”
1/4”
24
6.8
7.1
1 200
25
45 / 41 / 37
220 / 1 090 / 500
24.5
5/8”
3/8”
Indoor unit combinations
YJU2YH014 (2x1)
YJU2YH018 (2x1)
Number connecting units
2x1
7+7
7+9
7+12
Number connecting units
2x1
9+9
9+12
7+7
7+9
7+12
9+9
9+12
12+12
YJU3YH019 (3x1)
Number connecting units
2x1
3x1
7+7
7+9
7+12
7+18
9+9
9+12
9+18
12+12
12+18
7+7+7
7+7+9
7+7+12
7+7+18
7+9+9
7+9+12
7+12+12
9+9+9
9+9+12
9+12+12
YJU4YH025 (4x1)
Number connecting units
3x1
2x1
7+18
7+24
9+18
9+24
12+12
12+18
12+24
18+18
18+24
7+7+9
7+7+12
7+7+18
7+7+24
7+9+9
7+9+12
7+9+18
7+12+12
4x1
7+12+18
9+9+9
9+9+12
9+9+18
9+12+12
12+12+12
12+12+18
7+7+7+7
7+7+7+9
7+7+7+12
7+7+7+18
7+7+9+9
7+7+9+12
7+9+9+9
7+9+9+12
9+9+9+9
9+9+9+12
YJU4YH030 (4x1)
Number connecting units
3x1
2x1
7+24
9+18
9+24
12+18
12+24
18+18
18+24
24+24
7+7+18
7+7+24
7+9+12
7+9+18
7+9+24
7+12+12
7+12+18
7+12+24
9+9+9
9+9+12
4x1
9+9+18
9+9+24
9+12+12
9+12+18
9+12+24
12+12+12
12+12+18
12+12+24
12+18+18
7+7+7+7
7+7+7+9
7+7+7+12
7+7+7+18
7+7+7+24
7+7+9+9
7+7+9+12
7+7+9+18
7+7+9+24
7+7+12+12
7+7+12+18
7+9+9+9
7+9+9+12
7+9+9+18
7+9+12+12
7+12+12+12
9+9+9+9
9+9+9+12
9+9+12+12
9+9+12+18
9+12+12+12
12+12+12+12
YJU5YH034 (5x1)
2x1
7+18
7+24
9+18
9+24
12+18
12+24
18+18
18+24
24+24
Number connecting units
4x1
3x1
7+7+12
7+7+18
7+7+24
7+9+9
7+9+12
7+9+18
7+9+24
7+12+12
7+12+18
7+12+24
9+9+9
9+9+12
9+9+18
9+9+24
9+12+12
9+12+18
9+12+24
12+12+12
12+12+18
12+12+24
12+18+18
18+18+18
7+7+7+7
7+7+7+9
7+7+7+12
7+7+7+18
7+7+7+24
7+7+9+9
7+7+9+12
7+7+9+18
7+7+9+24
7+7+12+12
7+7+12+18
5x1
7+9+9+9
7+9+9+12
7+9+9+18
7+9+12+12
7+12+12+12
9+9+9+9
9+9+9+12
9+9+9+18
9+9+12+12
9+12+12+12
12+12+12+12
7+7+7+7+7
7+7+7+7+9
7+7+7+7+12
7+7+7+9+9
7+7+7+9+12
7+7+7+12+12
7+9+9+18
7+9+9+24
7+9+12+12
7+12+12+12
9+9+9+9
9+9+9+12
9+9+9+18
9+9+9+24
9+9+12+12
9+9+12+18
9+12+12+12
9+12+12+18
9+12+12+24
7+7+7+7+7
7+7+7+7+9
7+7+7+7+12
7+7+7+7+24
7+7+7+9+9
7+7+7+9+12
7+7+7+9+18
7+7+7+9+24
7+7+7+12+12
7+7+7+12+18
7+7+9+9+9
7+7+9+9+12
7+9+9+9+9
9+9+9+9+9
9+9+9+9+12
9+9+9+12+12
YJU5YH045 (5x1)
2x1
7+18
7+24
9+18
9+24
12+18
12+24
18+18
18+24
24+24
Number connecting units
4x1
3x1
7+7+12
7+7+18
7+7+24
7+9+9
7+9+12
7+9+18
7+9+24
7+12+12
7+12+18
7+12+24
9+9+9
9+9+12
9+9+18
9+9+24
9+12+12
9+12+18
9+12+24
12+12+12
12+12+18
12+12+24
12+18+18
12+18+24
18+18+18
7+7+7+7
7+7+7+9
7+7+7+12
7+7+7+18
7+7+7+24
7+7+9+9
7+7+9+12
7+7+9+18
7+7+9+24
7+7+12+12
7+7+12+18
7+7+12+24
7+9+9+9
7+9+9+12
5x1
7+7+7+12+24
7+7+9+9+9
7+7+9+9+12
7+7+9+9+18
7+7+9+9+24
9+9+9+9+9
9+9+9+9+12
9+9+9+9+18
9+9+9+12+12
9+9+9+12+18
Minisplit Systems
30/31
york air-conditioning products
Floor/Ceiling Inverter
YHFJZH 12 to 60
a complete range from 3.5 kW to 14.8 kW
UPDATED
VERSION
Features
Remote controller
• High SEER & SCOP, Class A or more
• Inverter DC compressor and fan motor
• Multi-speed fan motor
• Washable filter
• Fresh air intake
• Convertible - floor or ceiling
• Automatic restart
• Automatic air sweep
• Horizontal and vertical
air sweep function
• Wide angle air distribution
• Slim profile - flush mounting
• Low Ambient Kit (sizes 24 to 60)
• Electrical defrosting
• Self diagnosis
• Blue fin protection (indoor and outdoor units)
• Same indoor models as Multi Splits (sizes 12 to 24)
• Wireless
• 5 operation modes
(Cool/Heat/Auto/Dry/Fan)
• Sleep mode
• On/Off timer
• Turbo cool/heat settings
• Fan speed selection
• Air flow direction setting
• LED display
• Lock button
Minisplit Systems
32/33
Floor/Ceiling Inverter
YHFJZH 12 to 60
Technical features
Set reference
YHFJZH
Indoor unit
Sizes
YHFMXH 12
YHFMXH 18
YHFMXH 24
YHFMXH 28
YHFMXH 36
YHFMXH 48
YHFMXH 60
Outdoor unit
Sizes
YHUJYH 12
YHUJYH 18
YHUJYH 24
YHUJYH 28
YHUJYH 36
YHUJYH 48
YHUJYH 60
Cooling capacity
kW
3.5 (0.9~4.5)
5.0 (1.7~5.3)
6.5 (1.8~6.7)
8.3 (1.9~9.2)
9.3 (2.0~10.1)
12.3 (5.5~13.3)
14.8 (3.7~15.1)
Heating capacity
kW
3.9 (1.0~4.8)
5.4 (1.8~6.0)
6.7 (2.3~7.3)
9.0 (2.0~9.6)
10.6 (2.0~10.8)
13.8 (5.5~15.1)
15.2 (3.7~16.5)
Compressor
Type
230/1/50 or 400/3/50
400 / 3 / 50
Rotary
Refrigerant
R410A
Power supply
V/Ph/Hz
230 / 1 / 50
cooling
kW
1.05
1.55
2.31
2.57
2.90
3.97
5.02
heating
kW
1.08
1.53
2.22
2.48
2.93
4.08
4.62
EER
3.33
3.21
2.81
3.23
3.21
3.09
2.95
SEER
5.6
5.1
5.1
5.6
5.6
-
-
COP
3.61
3.52
3.01
3.63
3.62
3.38
3.28
3.8
3.8
3.8
3.8
3.8
-
-
A+
A
A
A+
A+
-
-
-
-
Power input
SCOP
Energy Class
cooling
heating
A
A
A
A
A
m3/h
650 / 550 / 450
800 / 720 / 650
850 / 800 / 720
1630 / 1537 / 1375
1630 / 1537 / 1375
Indoor (H/M/L)
dB(A)
41 / 37 / 33
44 / 41 / 36
44 / 41 / 36
49 / 45 / 43
49 / 45 / 43
53 / 51 / 49
Outdoor
dB(A)
52
54
57
58
58
59
60
H (mm)
655
655
655
700
700
700
700
W (mm)
990
990
990
1 298
1 298
1 580
1 580
D (mm)
199
199
199
240
240
240
240
H (mm)
540
688
730
840
840
830
1 250
W (mm)
780
810
860
948
948
1 008
948
D (mm)
245
288
308
340
340
410
340
Indoor unit
kg
26.3
28.3
28.3
37
37
54
54
Outdoor unit
kg
31.2
43
49
64
65
82
96
Indoor airflow (H/M/L)
Sound pressure
at 1 m
Indoor
Dimensions
Outdoor
Net weight
Type of connection
Piping
Pipe run
Diameter
2000 / 1800 / 1400 2000 / 1800 / 1400
53 / 51 / 49
Flare
Gas
3/8”
1/2”
5/8”
5/8”
5/8”
3/4”
3/4”
Liquid
1/4”
1/4”
3/8”
3/8”
3/8”
3/8”
3/8”
Length
m
15
25
25
30
30
50
50
Height
m
10
15
15
20
20
30
30
48
60
Operating limits - cooling mode
min/max
+18°C / +43°C
-10°C / +46°C
Operating limits - heating mode
min/max
-15°C / +24°C
-15°C / +24°C
Nominal cooling capacity based on : - Indoor Air Temp. 27°C DB / 19°C WB - Outdoor Air Temp. 35°C DB
Nominal heating capacity based on : - Indoor Air Temp. 21°C DB - Outdoor Air Temp. 7°C DB/6°C WB
Piping length : 5 m with initial charge
Size 48: Values for single phase models. For three phases models two models available (1 or two fans).
Accessories
Sizes
12
18
24
28
Wired control
Optional
Central control
Optional
Manufacturer reserves the rights to change specifications without prior notice.
36
york air-conditioning products
Cassette Inverter
YHKJZH 12 to 60
a complete range from 3.3 kW to 14.4 kW
UPDATED
VERSION
Features
Remote controller
• High SEER & SCOP, Class A or more
• Inverter DC compressor and fan motor
• Multi-speed fan motor
• Washable filter
• Fresh air intake
• Built-in drain pump
• Branch outlet
• Automatic restart
• Automatic air sweep
• Low Ambient Kit (sizes 24 to 60)
• Electrical defrosting
• Self diagnosis
• Blue fin protection (indoor and outdoor units)
• Same indoor models as Multi Splits (sizes 12 to 24)
• Wireless
• 5 operation modes
(Cool/Heat/Auto/Dry/Fan)
• Sleep mode
• On/Off timer
• Turbo cool/heat settings
• Fan speed selection
• Air flow direction setting
• LED display
• Lock button
Minisplit Systems
34/35
Cassette Inverter
YHKJZH 12 to 60
Technical features
Set reference
YHKJZH
Indoor unit
Sizes
YHKMXH 12
YHKMXH 18
YHKMXH 24
YHKMXH 28
YHKMXH 36
YHKMXH 48
Outdoor unit
Sizes
YHUJYH 12
YHUJYH 18
YHUJYH 24
YHUJYH 28
YHUJYH 36
YHUJYH 48
YHUJYH 60
Cooling capacity
kW
3.3 (0.9~4.5)
4.8 (1.8~5.8)
6.7 (2.0~7.3)
7.8 (2.0~8.7)
9.3 (2.0~10.3)
12.1 (6.0~13.8)
14.4 (3.7~15.1)
Heating capacity
kW
3.5 (0.9~4.4)
5.0 (2.0~6.1)
7.0 (2.5~8.0)
8.5 (2.5~9.3)
9.4 (2.3~10.8)
12.6 (5.5~14.7)
15.4 (3.7~16.0)
Compressor
Type
Rotary
Refrigerant
R410A
Power supply
Power input
YHKMXH 60
V/Ph/Hz
230/1/50 or 400/3/50
400 / 3 / 50
Cooling
kW
1.09
1.59
2.22
2.59
3.30
4.11
5.12
Heating
kW
1.02
1.56
1.94
2.53
2.78
4.07
5.11
3.01
3.01
3.01
3.01
3.10
2.94
2.81
EER
230 / 1 / 50
SEER
5.1
5.1
5.7
5.2
5.2
-
-
COP
3.41
3.21
3.61
3.36
3.38
3.10
3.01
3.8
3.8
3.8
3.8
3.8
-
-
A
A
A+
A
A
-
-
A
-
-
SCOP
Energy Class
Cooling
Heating
A
A
A
A
m3/h
620/520/450
700/620/500
1300/1100/870
1300/1100/870
Indoor (H/M/L)
dB(A)
40 / 36 / 32
42 / 37 / 35
46 / 44 / 39
48 / 46 / 44
49 / 47 / 44
49 / 47 / 44
Outdoor
dB(A)
52
54
57
58
58
59
60
H (mm)
260
260
240
240
290
290
280
W (mm)
570
570
840
840
840
840
1 230
D (mm)
570
570
840
840
840
840
840
H (mm)
540
688
730
840
840
830
1 250
W (mm)
780
810
860
948
948
1 008
948
D (mm)
245
288
308
340
340
410
340
Indoor airflow (H/M/L)
Sound pressure
at 1 m
Indoor
Dimensions
Outdoor
Net weight
Pipe run
49 / 44 / 42
Panel H / W / D
mm
60 / 700 / 700
60 / 700 / 700
60 / 950 / 950
60 / 950 / 950
60 / 950 / 950
60 / 950 / 950
80 / 950 / 1 340
Indoor unit
kg
18.5
18.5
26.8
26.8
31
38
46
Outdoor unit
kg
32
43
49
64
65
82
96
Panel
kg
2.8
2.8
4.2
4.2
4.2
4.2
8.4
Gas
3/8”
1/2”
5/8”
5/8”
5/8”
3/4”
3/4”
Liquid
1/4”
1/4”
3/8”
3/8”
3/8”
3/8”
3/8”
Type of connection
Piping
1600/1450/1300 1600/1450/1300 1980/1750/1500
Diameter
Flare
Length
m
15
25
25
30
30
50
50
Height
m
10
15
15
20
20
30
30
48
60
Operating limits - cooling mode
min/max
18°C / +43°C
-10°C / +46°C
Operating limits - heating mode
min/max
-15°C / +24°C
-15°C / +24°C
Nominal cooling capacity based on : - Indoor Air Temp. 27°C DB / 19°C WB - Outdoor Air Temp. 35°C DB
Nominal heating capacity based on : - Indoor Air Temp. 21°C DB - Outdoor Air Temp. 7°C DB/6°C WB
Piping length : 5 m with initial charge
Size 48: values for single phase models. For three phases models two models available (1 or two fans).
Accessories
Sizes
12
18
24
28
Wired control
Optional
Central control
Optional
Manufacturer reserves the rights to change specifications without prior notice.
36
york air-conditioning products
Blower Inverter
YH3JZH 12 to 24 / YHEJZH 28 to 48 / YHGJZH 48 to 60
a complete range from 3.5 kW to 15.2 kW
UPDATED
VERSION
Features
Wired control
• High SEER & SCOP, Class A
• Inverter DC compressor and fan motor
• Washable filter
• Automatic restart
• Condensate pump optional
• Quiet operation
• Wired control
• Low Ambient Kit (sizes 24 to 60)
• Electrical defrosting
• Self diagnosis
• Blue fin protection (indoor and
outdoor units)
• Same indoor models as Multi Splits
(sizes 12 to 24)
• 5 operation modes
(Cool/Heat/Auto/Dry/Fan)
• Sleep mode
• Room temperature setting
• Fan speed selection
• Timer
• LCD display
• 3-minute protection
• Weekly timer
Minisplit Systems
36/37
Blower Inverter
YH3JZH 12 to 24 / YHEJZH 28 to 48 / YHGJZH 48 to 60
Technical features
Model
LOW STATIC PRESSURE *
MEDIUM STATIC PRESSURE
YH3JZH
YHEJZH
Set reference
HIGH STATIC PRESSURE
YHGJZH
Indoor unit
Sizes
YH3MXH 12
YH3MXH 18
YH3MXH 24
YHEJXH 28
YHEJXH 36
YHEJXH 48
YHGJXH 48
YHGJXH 60
Outdoor unit
Sizes
YHUJYH 12
YHUJYH 18
YHUJYH 24
YHUJYH 28
YHUJYH 36
YHUJYH 48
YHUJYH 48
YHUJYH 60
Cooling capacity
kW
3.3 (0.8~4.1)
5.0 (1.7~5.5)
7.1 (1.8~7.5)
8.0 (1.9~9.0)
9.3 (2.0~10.1)
12.2 (5.6~13.6) 12.4 (5.6~13.6) 15.2 (3.7~15.8)
Heating capacity
kW
3.9 (0.9~4.4)
5.4 (1.8~6.0)
7.1 (2.8~7.6)
8.8 (2.0~9.6)
10.2 (2.0~11.0) 13.6 (5.6~15.4) 13.7 (5.6~15.4)
Compressor
Type
16.0 (3.7~17.0)
Rotary
Refrigerant
R410A
Power supply
V/Ph/Hz
230 / 1 / 50
230/1/50 or 400/3/50
400 / 3 / 50
cooling
kW
1.02
1.55
2.21
2.83
3.31
4.34
4.31
5.37
heating
kW
1.14
1.53
1.96
2.58
2.99
4.24
3.80
4.68
EER
3.21
3.21
3.21
2.82
2.81
2.81
2.87
2.83
SEER
5.1
5.1
5.6
5.1
5.1
-
-
-
COP
3.41
3.51
3.61
3.41
3.41
3.21
3.61
3.42
Power input
3.8
3.8
4.0
3.8
3.8
-
-
-
cooling
A
A
A+
A
A
-
-
-
heating
A
A
A+
A
A
-
-
-
550
900
1 100
2 090
2 090
2 090
2 580
2 580
SCOP
Energy Class
Indoor airflow
m3/h
External static pressure
Sound pressure
at 1 m
0 / 30
0 / 30
0 / 30
50 / 100
50 / 100
50 / 100
50 / 150
50 / 150
33 / 28 / 23
36 / 30 / 26
39 / 32 / 29
48 / 46 / 42
48 / 46 / 42
49 / 47 / 43
50 / 46 / 42
50 / 46 / 42
dB(A)
Outdoor
dB(A)
52
54
57
58
58
59
58
59
H (mm)
185
185
185
270
270
270
360
360
1 197
Indoor
Dimensions
Outdoor
Net weight
Pa
Indoor (H/M/L)
W (mm)
850
1 117
1 117
1 135
1 135
1 135
1 197
D (mm)
420
420
420
742
742
742
830
830
H (mm)
540
688
730
840
840
830
830
1 250
W (mm)
780
810
860
948
948
1 008
1 008
948
D (mm)
245
288
308
340
340
410
410
340
Indoor unit
kg
17
25
27
45.4
45.4
52
70
70
Outdoor unit
kg
31.2
43
49
64
65
82
82
96
Type of connection
Piping
Pipe run
Diameter
Flare
Gas
3/8”
1/2”
5/8”
5/8”
5/8”
3/4”
3/4”
3/4”
Liquid
1/4”
1/4”
3/8”
3/8”
3/8”
3/8”
3/8”
3/8”
Length
m
15
25
25
30
30
50
50
50
Height
m
10
15
15
20
20
30
30
30
-10°C / +46°C
18°C / +43°C
Operating limits - cooling mode
min/max
Operating limits - heating mode
min/max
-10°C / +46°C
-15°C / +24°C
Nominal cooling capacity based on : - Indoor Air Temp. 27°C DB / 19°C WB - Outdoor Air Temp. 35°C DB
Nominal heating capacity based on : - Indoor Air Temp. 21°C DB - Outdoor Air Temp. 7°C DB/6°C WB
Piping length : 5 m with initial charge
Sizes 48: Values for single phase models. For three phases models two models available (1 or two fans).
* Low static pressure models also available as indoor standard duct units (YHDMXH). For technical specifications reference to Multi Split pages.
Accessories
Sizes
12
18
24
28
36
Condensate pump
Optional
Central control
Optional
Manufacturer reserves the rights to change specifications without prior notice.
48
48
60
york air-conditioning products
38/39
Minisplit
On/Off Systems
high wall units
multisplits
cassette, floor/ceiling & blower units
window units
york air-conditioning products
High Wall On/Off
YKHFZH 09 to 24
a complete range from 2.6 kW to 6.8 kW
NEW
Features
Remote controller
• Low noise levels
• Dry mould proof
• Automatic restart
• Automatic air sweep
• Sleep mode function
• Self-diagnosis
• Easy maintenance
• Service valve protection cover
• Blue fin protection (indoor and
outdoor units)
• Wireless
• 5 operation modes
(Cool/Heat/Auto/Dry/Fan)
• Sleep mode
• On/Off timer
• Turbo cool/heat settings
• Fan speed selection
• Air flow direction setting
• LED display
• Lock button
Minisplit Systems
40/41
High Wall On/Off
YKHFZH 09 to 24
Technical features
Set reference
YKHFZH
Indoor unit
Sizes
YKHFXH 09
YKHFXH 12
YKHFXH 18
YKHFXH 24
Outdoor unit
Sizes
YKHFYH 09
YKHFYH 12
YKHFYH 18
YKHFYH 24
Cooling capacity
kW
2.6
3.4
5.1
6.8
Heating capacity
kW
2.7
3.8
5.3
7.0
Compressor
Type
Rotary
Refrigerant
R410A
Power supply
V/Ph/Hz
230 / 1 / 50 + E
cooling
kW
0.94
1.25
1.84
2.56
heating
kW
0.85
1.24
1.97
2.44
EER
2.81
2.81
2.86
2.75
COP
3.28
3.31
2.83
3.00
cooling
C
C
C
D
heating
C
C
D
D
m3/h
450
500
700
1 100
Indoor (L/M/H)
dB(A)
34 / 37 / 39
35 / 38 / 42
37 / 39 / 42
40 / 44 / 47
Outdoor
dB(A)
52
53
52
54
H (mm)
265
265
265
299
W (mm)
795
795
938
1 046
D (mm)
187
187
187
239
H (mm)
540
540
643
732
Outdoor
W (mm)
660
660
783
865
D (mm)
275
275
255
335
Indoor unit
kg
7.7
8.8
10.5
13
Outdoor unit
kg
26
28
43
58.5
Gas
3/8”
3/8”
1/2”
5/8”
Liquid
1/4”
1/4”
1/4”
1/4”
Power input
Energy Class
Indoor airflow (high speed)
Sound pressure
at 1 m
Indoor
Dimensions
Net weight
Type of connection
Piping
Diameter
Refrigerant charge
Pipe run
Flare
g
600
840
1 150
1 550
Length
m
15
15
25
25
Height
m
10
10
15
15
18
24
Operating limit - cooling mode
min./max.
+18°C / +43°C
Operating limit - heating mode
min./max.
-7°C / +24°C
Nominal cooling capacity based on : - Indoor Air Temp. 27°C DB / 19°C WB - Outdoor Air Temp. 35°C DB
Nominal heating capacity based on : - Indoor Air Temp. 21°C DB - Outdoor Air Temp. 7°C DB/6°C WB
Piping length : 5 m with initial charge
Accessories
Sizes
09
12
Electrostatic dedusting filter
Optional
Silver ion filter
Optional
Active carbon filter
Optional
Non available for EC countries.
Manufacturer reserves the rights to change specifications without prior notice.
york air-conditioning products
High Wall On/Off
EAHC 09 to 24 FS-Q
A complete range from 2.5 kW to 6.2 kW
Features
Remote controller
• Low noise levels
• Class A
• Automatic restart
• ON/OFF timer
• Automatic air sweep
• Service valve protection cover
• Rustproof casing
• Blue fin protection (indoor and
outdoor units)
• Wireless
• 5 operation modes
(Cool/Heat/Auto/Dry/Fan)
• Sleep mode
• Room temperature setting
• Fan speed selection
• Timer setting function
• Air flow direction setting
• LCD display
Minisplit Systems
42/43
High Wall On/Off
EAHC 09 to 24 FS-Q
Technical features
Set reference
EAHC FS-Q
Indoor unit
Sizes
EAKC 09 FS-Q
EAKC 12 FS-Q
EAKC 18 FS-Q
EAKC 24 FS-Q
Outdoor unit
Sizes
EAJC 09 FS-Q
EAJC 12 FS-Q
EAJC 18 FS-Q
EAJC 24 FS-Q
Cooling capacity
kW
2.5
3.1
4.6
6.2
Heating capacity
kW
2.7
3.4
5.0
6.5
Compressor
Type
Rotary
Refrigerant
R410A
Power supply
V/Ph/Hz
230 / 1 / 50 + E
cooling
kW
0.80
1.00
1.50
1.90
heating
kW
0.82
0.99
1.35
1.90
EER
3.21
3.21
3.21
3.22
COP
3.41
3.41
3.63
3.41
cooling
A
A
A
A
heating
B
B
A
B
m3/h
350
400
750
780
Indoor (L/M/H)
dB(A)
32 / 35 / 37
32 / 35 / 38
37 / 41 / 45
38 / 41 / 45
Outdoor
dB(A)
50
52
55
56
H (mm)
255
265
298
298
W (mm)
730
790
940
940
D (mm)
174
170
200
200
H (mm)
540
540
540
680
W (mm)
776
798
848
913
D (mm)
320
355
360
428
Power input
Energy Class
Indoor airflow (high speed)
Sound pressure
at 1 m
Indoor
Dimensions
Outdoor
Net weight
Indoor unit
kg
8
9
13
13
Outdoor unit
kg
31
35
40
46
Gas
3/8”
1/2”
1/2”
1/2”
Liquid
1/4”
1/4”
1/4”
1/4”
1 450
Type of connection
Piping
Diameter
Refrigerant charge
Pipe run
Flare
g
660
840
1 150
Length
m
15
20
25
25
Height
m
5
10
10
10
18
24
Operating limit - cooling mode
min./max.
+18°C / +46°C
Operating limit - heating mode
min./max.
-7°C / +24°C
Nominal cooling capacity based on : - Indoor Air Temp. 27°C DB / 19°C WB - Outdoor Air Temp. 35°C DB
Nominal heating capacity based on : - Indoor Air Temp. 21°C DB - Outdoor Air Temp. 7°C DB/6°C WB
Piping length : 5 m with initial charge
Accessories
Sizes
09
12
Electrostatic dedusting filter
Optional
Silver ion filter
Optional
Active carbon filter
Optional
Non available for EC countries.
Manufacturer reserves the rights to change specifications without prior notice.
york air-conditioning products
Floor/Ceiling
EOHC 09 to 48 FS
A complete range from 2.5 kW to 13.2 kW
Features
Remote controller
• Convertible - floor or ceiling
• Horizontal and vertical
air sweep function
• Wide angle air distribution
• Slim profile - flush mounting
• Low Ambient Kit optional
• Rustproof casing
• Blue fin protection (indoor and
outdoor units)
• Wireless
• 5 operation modes
(Cool/Heat/Auto/Dry/Fan)
• Sleep mode
• Room temperature setting
• Fan speed selection
• Timer
• LCD display
Wired control
(optional)
• 5 operation modes
(Cool/Heat/Auto/Dry/Fan)
• Sleep mode
• Room temperature setting
• Fan speed selection
• Timer
• LCD display
Minisplit Systems
44/45
Floor/Ceiling
EOHC 09 to 48 FS
Technical features
Set reference
EOHC
Indoor unit
Sizes
EOKC 09 FS
EOKC 12 FS
EOKC 18 FS
EOKC 24 FS
EOKC 36 FS
EOKC 42 FS
EOKC 48 FS
Outdoor unit
Sizes
ENJC 09 FS
ENJC 12 FS
ENJC 18 FS
ENJC 24 FS
ENJC 36 FS
ENJC 42 FS
ENJC 48 FS
Cooling capacity
kW
2.5
3.5
5.2
7.2
10.0
12.0
13.2
Heating capacity
kW
2.8
3.9
5.7
8.0
11.0
14.0
14.5
Compressor
Type
Rotary
Scroll
Refrigerant
R410A
Power supply
Power input
V/Ph/Hz
230 / 1 / 50 + E
400 / 3 / 50 + E + N
cooling
kW
0.89
1.23
1.80
2.50
3.50
4.50
5.00
heating
kW
0.98
1.29
2.00
2.59
3.30
4.70
4.80
EER
2.81
2.85
2.89
2.88
2.86
2.67
2.64
COP
2.85
3.02
2.85
3.09
3.33
2.98
3.02
cooling
C
C
C
C
C
D
D
heating
D
D
D
D
C
D
D
Energy Class
Fuse rating
A
25
25
25
25
16
16
16
Indoor airflow (high speed)
m3/h
550
600
700
1 170
1 800
1 800
2 100
Indoor (H/M/L)
dB(A)
45 / 42 / 39
46 / 42 / 38
54 / 50 / 46
50 / 48 / 46
54 / 51 / 48
54 / 51 / 48
58 / 55 / 52
Outdoor
dB(A)
54
56
56
59
58
60
63
H (mm)
695
695
695
600
695
695
695
1 590
Sound pressure
at 1 m
W (mm)
836
836
836
1 300
1 590
1 590
D (mm)
238
238
238
188
238
238
238
H (mm)
540
540
540
695
840
1 250
1 250
W (mm)
820
820
820
1 018
1 018
1 032
1 032
D (mm)
320
320
320
412
412
412
412
Indoor unit
kg
27
27
27
32
42
42
48
Outdoor unit
kg
30
40
40
59
90
112
112
Gas
1/2”
1/2”
1/2”
5/8”
3/4”
3/4”
3/4”
Liquid
1/4”
1/4”
1/4”
3/8”
1/2”
1/2”
1/2”
g
1 100
1 000
1 500
2 200
3 200
3 550
3 800
Length
m
20
20
20
30
50
50
50
Height
m
15
15
15
15
30
30
30
36
42
48
Indoor
Dimensions
Outdoor
Net weight
Type of connection
Piping
Diameter
Refrigerant charge
Pipe run
Flare
Operating limits - cooling mode
min/max
-10°C / +43°C
Operating limits - heating mode
min/max
-15°C / +24°C
Nominal cooling capacity based on : - Indoor Air Temp. 27°C DB / 19°C WB - Outdoor Air Temp. 35°C DB
Nominal heating capacity based on : - Indoor Air Temp. 21°C DB - Outdoor Air Temp. 7°C DB/6°C WB
Piping length : 5 m with initial charge
Accessories
Sizes
09
12
18
24
Wired control
Optional
Weekly timer
Optional
Central control
Optional
Low Ambient Kit
Optional
Non available for EC countries.
Manufacturer reserves the rights to change specifications without prior notice.
york air-conditioning products
Cassette
EKHC 12 to 48 FS
A complete range from 3.5 kW to 14.2 kW
Features
Remote controller
• Condensate pump
• Fresh air intake for sizes 24 to 42
• 3 fan speeds
• 600 x 600 mm (size 12 & 18)
• Auto restart
• Low noise operation
• Low Ambient Kit optional
• Rustproof casing
• Blue fin protection (indoor and
outdoor units)
• Wireless
• 5 operation modes
(Cool/Heat/Auto/Dry/Fan)
• Sleep mode
• Room temperature setting
• Fan speed selection
• Timer
• LCD display
Wired control
(optional)
• 5 operation modes
(Cool/Heat/Auto/Dry/Fan)
• Sleep mode
• Room temperature setting
• Fan speed selection
• Timer
• LCD display
Minisplit Systems
46/47
Cassette
EKHC 12 to 48 FS
Technical features
Set reference
EKHC
Indoor unit
Sizes
EKKC 12 FS
EKKC 18 FS
EKKC 24 FS
EKKC 36 FS
EKKC 42 FS
EKKC 48 FS
Outdoor unit
Sizes
ENJC 12 FS
ENJC 18 FS
ENJC 24 FS
ENJC 36 FS
ENJC 42 FS
ENJC 48 FS
Cooling capacity
kW
3.5
5.3
7.0
10.0
12.0
13.2
Heating capacity
kW
3.6
5.7
7.5
11.0
14.0
14.5
Compressor
Type
Rotary
Scroll
Refrigerant
R410A
Power supply
V/Ph/Hz
230 / 1 / 50 + E
400 / 3 / 50 + E
Cooling
kW
1.15
1.85
2.50
3.50
4.60
4.80
Heating
kW
1.10
1.75
2.50
3.40
4.80
5.20
EER
3,04
2,86
2,80
2,86
2,61
2,75
COP
3,27
3,26
3,00
3,24
2,92
2,79
D
Power input
Energy Class
Cooling
B
C
C
C
D
Heating
C
C
D
C
D
E
Indoor airflow
m3/h
550
550
1 180
1 660
1 660
1 660
Sound pressure Indoor (H/M/L)
at 1 m
Outdoor
dB(A)
47 / 45 / 43
47 / 45 / 43
47 / 45 / 43
53 / 51 / 48
53 / 51 / 48
53 / 51 / 48
dB(A)
56
56
59
60
60
63
H (mm)
230
230
240
320
320
320
Indoor
Dimensions
Outdoor
Net weight
W (mm)
600
600
840
840
840
840
D (mm)
600
600
840
840
840
840
H (mm)
540
540
695
840
1 250
1 250
W (mm)
820
820
1 018
1 018
1 032
1 032
D (mm)
320
320
412
412
412
412
50 / 650 / 650
60 / 950 / 950
60 / 950 / 950
60 / 950 / 950
60 / 950 / 950
Panel H/W/D
mm
50 / 650 / 650
Indoor unit
kg
20
20
30
38
38
32
Outdoor unit
kg
32
40
59
90
112
112
Gas
1/2”
1/2”
5/8”
3/4”
3/4”
3/4”
Liquid
1/4”
1/4”
3/8”
1/2”
1/2”
1/2”
g
1 000
1 500
2 200
3 200
3 550
3 800
Length
m
20
20
30
50
50
50
Height
m
15
15
15
30
30
30
36
42
48
Type of connection
Piping
Diameter
Refrigerant charge
Max pipe run
Flare
Operating limits - cooling mode
min/max
-10°C / +43°C
Operating limits - heating mode
min/max
-15°C / +24°C
Nominal cooling capacity based on : - Indoor Air Temp. 27°C DB / 19°C WB - Outdoor Air Temp. 35°C DB
Nominal heating capacity based on : - Indoor Air Temp. 21°C DB - Outdoor Air Temp. 7°C DB/6°C WB
Piping length : 5 m with initial charge
Accessories
Sizes
12
18
24
Wired control
Optional
Weekly timer
Optional
Central control
Optional
Low Ambient Kit
Optional
Non available for EC countries.
Manufacturer reserves the rights to change specifications without prior notice.
york air-conditioning products
Blower
EUHC 12 to 60 FT
A complete range from 3.5 kW to 16.0 kW
Features
Wired control
• Air filter included
• Condensate pump optional
• Fresh air intake
• Indoor unit with centrifugal fan
• Large distances between indoor
and outdoor units
• Indoor units with high pressure
• Quiet operation
• Wired control with weekly timer
• Infrared remote control
• Low Ambient Kit optional
• Blue fin protection (indoor and
outdoor units)
• 5 operation modes
(Cool/Heat/Auto/Dry/Fan)
• Sleep mode
• Room temperature setting
• Fan speed selection
• Weekly timer
• LCD display
Remote controller
• Wireless
• 5 operation modes
(Cool/Heat/Auto/Dry/Fan)
• Sleep mode
• Room temperature setting
• Fan speed selection
• Timer
• Air flow direction setting
• LCD display
Minisplit Systems
48/49
Blower
EUHC 12 to 60 FT
Technical features
EUHC
Set reference
Indoor unit
Sizes
EUKC 12 FT
EUKC 18 FT
EUKC 24 FT
EUKC 36 FT
EUKC 42 FT
EUKC 48 FT
EUKC 60 FT
Outdoor unit
Sizes
ENJC 12 FS
ENJC 18 FS
ENJC 24 FS
ENJC 36 FS
ENJC 42 FS
ENJC 48 FS
ENJC 60 FS
Cooling capacity
kW
3.5
5.2
7.0
10.2
12.2
13.2
16.0
Heating capacity
kW
3.6
5.7
8.0
11.2
14.0
14.5
18.5
Compressor
Type
Power supply
Rotary
Scroll
230 / 1 / 50 + E
V/Ph/Hz
400 / 3 / 50 + E + N
cooling
kW
1.1
1.85
2.60
3.70
4.80
5.10
6.30
heating
kW
1.1
1.75
2.50
3.50
4.90
4.60
6.00
EER
3.18
2.81
2.69
2.76
2.54
2.58
2.54
COP
3.27
3.26
3.20
3.20
2.86
3.15
3.08
cooling
B
C
D
D
E
E
E
heating
C
C
C
C
D
D
D
2 500
Power input
Energy Class
Indoor airflow
m3/h
600
840
1 400
2 000
2 000
2 300
External static pressure
Pa
25
40
80
150
150
150
150
40 / 38 / 36
42 / 40 / 38
44 / 42 / 40
50 / 48 / 46
50 / 48 / 46
53 / 50 / 46
53 / 50 / 48
Sound pressure
at 1 m
Indoor
dB(A)
Outdoor
dB(A)
56
56
59
60
60
63
64
H (mm)
220
266
268
290
290
290
330
W (mm)
913
1 012
1 270
1 226
1 226
1 226
1 226
D (mm)
680
736
530
775
775
775
815
H (mm)
540
540
695
840
1 250
1 250
1 250
Indoor
Dimensions
W (mm)
820
820
1 018
1 018
1 032
1 032
1 032
D (mm)
320
320
412
412
412
412
412
Indoor unit
kg
27
36
37
57
57
57
66
Outdoor unit
kg
32
40
59
90
112
112
123
Gas
1/2”
1/2”
5/8”
3/4”
3/4”
3/4”
3/4”
Liquid
1/4”
1/4”
3/8”
1/2”
1/2”
1/2”
1/2”
g
1 000
1 500
2 200
3 200
3 550
3 800
5 000
Length
m
20
20
30
50
50
50
50
Height
m
15
15
15
30
30
30
30
42
48
60
Outdoor
Net weight
Type of connection
Piping
Diameter
Refrigerant charge
Pipe run
Flare
Operating limits - cooling mode
min/max
-10°C / +43°C
Operating limits - heating mode
min/max
-15°C / +24°C
Nominal cooling capacity based on : - Indoor Air Temp. 27°C DB / 19°C WB - Outdoor Air Temp. 35°C DB
Nominal heating capacity based on : - Indoor Air Temp. 21°C DB - Outdoor Air Temp. 7°C DB/6°C WB
Piping length : 5 m with initial charge
Accessories
Sizes
12
18
24
36
Condensate pump
Optional
Low Ambient Kit
Optional
Central control
Optional
Non available for EC countries.
Manufacturer reserves the rights to change specifications without prior notice.
york air-conditioning products
Information for minisplit installation
Model
Size
High wall
Inverter
YWHJZH
R410A
09
12
18
24
High wall
Inverter
YEHJZH
R410A
09
12
18
24
High wall
Inverter
YLHJZH
R410A
09
12
18
24
High wall
Inverter
YJHJZH
R410A
09
12
18
24
High wall
On-Off
YKHFZH
R410A
09
12
18
24
High wall
On-Off
EAHC-FS-Q
R410A
09
12
18
24
Power
supply
Indoor
Power
supply
cable size
(mm2)
3 x 2.5
Interconnection
cables
(number of cables
and sizes)
(mm2)
4 x 2.5
Maximum
pipe run
(m)
Maximum
height
(m)
YWHJZH
15
20
Piping
diameter
Liquid - gas
Outdoor unit
charged
for a piping
length of
(m)
1/4 - 3/8”
10
25
1/4 - 1/2”
Extra
refrigerant
charge for
every meter
(gr)
20
5
50
1/4 - 5/8”
YEHJZH
15
Indoor
3 x 2.5
1/4 - 3/8”
4 x 2.5
10
25
1/4 - 1/2”
1/4 - 5/8”
20
5
50
YLHJZH
3 x 1.5
Outdoor
3 x 2.5
3x4
1/4 - 3/8”
4 x 0.75
15
10
1/4 - 1/2”
3/8 - 5/8”
20
5
50
YJHJZH
3 x 1.5
Outdoor
3 x 2.5
3x4
15
10
1/4 - 3/8”
15
1/4 - 1/2”
3/8 - 5/8”
10
1/4 - 3/8”
25
15
1/4 - 1/2”
1/4 - 5/8”
EAHC-FS-Q
15
20
5
1/4 - 3/8”
4 x 0.75
25
20
5
50
YKHFZH
3 x 1.5
Outdoor
Indoor
3 x 2.5
3x4
15
4 x 0.75
3 x 2.5
5 x 2.5
3x4
6x4
3 x 2.5
4 x 0.75
25
10
1/4 - 1/2”
20
5
50
20
5
30
50
YJU_YH
Multisplit
Inverter
YJU_YH
R410A
Floor/Ceiling
Inverter
YHFJZH
Cassette Inverter
YHKJZH
Blower Inverter
YHDJZH
R410A
14
18
19
25
30
34
12
18
24
28
36
48
60
30
50
Outdoor
3x4
4 x 2.5
1/4-3/8” **
15 *
70
80
YHFJZH / YHKJZH / YHDJZH
15
10
3 x 2.5
Outdoor
3x6
4 x 0.75
3x4
5*
40 *
1/4-3/8” **
1/4-1/2” **
25
15
30
20
50
30
1/4 - 3/8”
1/4 - 1/2”
3/8 - 5/8”
30
5
60
120
3/8 - 3/4”
EOHC / EKHC / EUHC
Floor/Ceiling
EOHC
Cassette
EKHC
Blower
EUHC
R410A
09
12
18
24
36
42
48
60
Ind: 3 x 1.5
Out: 3 x 2.5
Outdoor &
Indoor
Ind: 3 x 1.5
Out: 3 x 4
Ind: 3 x 1.5
Out: 3 x 6
Ind: 3 x 1.5
Out: 5 x 2.5
* Each indoor unit
** 2, 3, 4 or 5 piping connections (Liquid - Gas)
Confirm about data in the technical documentation.
20
2 x 0.25
15
30
50
1/4 - 1/2”
3/8 - 5/8”
30
1/2 - 3/4”
30
5
60
120
Minisplit Systems
50/51
Load calculation
Customer
Date
Telephone
Type of installation
Project
Adress
Termical loads
PARAMETERS
FACTOR
CAPACITY
not exposed to sunlight
m
2
x
50
=
exposed to sunlight
m
2
x
180
=
exposed to sunlight with curtains
m2
x
135
=
exposed to sunlight with awnings
m2
x
90
=
exposed to sunlight and insulated
m2
x
9
=
exposed to sunlight non insulated
m
2
x
23
=
not exposed to sunlight and insulated
m
2
x
7
=
not exposed to sunlight non insulated
m
2
x
12
=
m2
x
10
=
insulated
m2
x
5
=
not insulated
m
2
x
12
=
insulation under the roof
m
2
x
10
=
not insulation under roof
m
2
x
24
=
insulated
m2
x
7
=
not insulated
m
x
10
=
FRESH AIR
m3/h
x
4,5
=
PERSONS INSIDE THE ROOM
pers.
x
144
=
W
x
1
=
WINDOWS
OUTDOOR
WALLS
INDOOR WALLS *
CEILING
OR ROOF *
FLOOR *
2
WORKING ELECTRICAL EQUIPMENT
NEEDED COOLING CAPACITY
W
* To not consider if they are next to climatisated area.
Important: This is a simplified method to obtain an approximate value of cooling capacity,
as long as the climatic conditions are not extreme.
Only for cooling calculation.
york air-conditioning products
52/53
VRF Systems
yv2v • r410a
indoor unit types
york air-conditioning products
Amazon Standard Ambient VRF System
YV2V 010 to 135
Cooling capacities 9 kW to 135 kW
VRF System
Comfort – Quality
• Capacities from 9 to 135 kW
• Operating range of nominal power
(10% - 130 %)
• DC Inverter Scroll Compressor
• Low noise levels
• High Efficiency. EER up to 4.28
• Modular design
• Large indoor unit combinations
• Flexible and quickly installation
• Cooling and heating
• Connection up to 64 indoor units
per refrigeration circuit
(3 outdoor units)
• Complete range in R410A
• Reduced space of ground
• Is appropriate particularly for
existing buildings
• Cooling to -5°C to +43°C
(outdoor temperature)
• Heating to -15°C to +24°C
(outdoor temperature)
VRF Systems
54/55
Amazon Standard Ambient VRF System
YV2V 010 to 135
YV2V DC INVERTER VRF
The YV2V (YORK Inverter Air Conditioner)
air-conditioner is the system that has
variable-frequency compressor and multiple
evaporators (indoor units). It is widely used
in the world for high efficiency. It provides
a broad range of different applications for
settings such as offices, hotels and schools.
With the advantage of easy installation and
simple controlling system and so on, the
YV2V system can better meet the demands
of the air conditioning market.
Flexible indoor unit combinations
Each outdoor unit allows to connect up to 16 indoor
units. This quantity varies in accordance with the
model. The total capacity of the indoor units can
vary between 50% and 130% from the total outdoor
unit nominal capacity.
High Wall
Low Static
Pressure
Duct
Floor/Ceiling
Medium Static
Pressure
Duct
Four-way
Cassette
High Static
Pressure
Duct
Console
Fresh-air
indoor units
22.6 - 45.0 kW
9.0 - 18.0 kW
67.8 - 135.0 kW
45.2 - 90.0 kW
Manufacturer reserves the rights to change specifications without prior notice.
york air-conditioning products
Amazon Standard Ambient VRF System
YV2V 010 to 045
YV2V Technical features - Mini-VRF outdoor unit
Model
Cooling capacity
YV2VYH010KAR
YV2VYH015KAR
YV2VYH015KAS
9.0
15.0
15.0
18.0
2.98
3.33
3.06
2.84
20.0
kW
EER
Heating capacity
kW
COP
YV2VYH018KAS
11.0
17.0
17.0
4.20
3.78
3.95
3.37
Air flow
m3/h
3 500
6 500
6 500
6 500
Sound Pressure Level at 1 m
dB(A)
58
59
59
60
Power input “cooling”
kW
3.02
4.50
4.90
6.33
Power input “heating”
kW
2.62
4.50
4.30
5.93
Compressor
Type
Rotary
Rotary
Rotary
Rotary
Height x Width x Length
mm
830 x 960 x 380
1 250 x 960 x 380
1 250 x 960 x 380
1 250 x 960 x 380
Weight
kg
74
120
120
120
Gas
5/8”
3/4”
3/4”
3/4”
Liquid
3/8”
3/8”
3/8”
3/8”
Electrical features
Power supply
1/N/ 230V 50Hz
3/N/ 400V 50Hz
Dimensions and Weight
Piping connections
Refrigerant charge
Type
R410A
kg
2.6
3.6
4
4
Piping length / Height difference
Max. piping length
m
50
100
100
100
Max. height difference
m
30
30
30
30
4
8
8
9
Max. number of indoor units
YV2V Technical features - Single module outdoor unit
Model
YV2VYH022KAS
YV2VYH028KAS
YV2VYH033KAS
YV2VYH040KAS
YV2VYH045KAS
22.6
28.0
33.5
40.0
45.0
4.28
3.80
3.35
3.51
3.36
kW
25.0
31.5
37.5
45.0
50.0
4.24
3.95
3.75
3.88
3.70
Air flow
m3/h
11.100
11.100
14.100
14.100
14.100
Sound Pressure Level at 1 m
dB(A)
57
57
60
60
60
Power input “cooling”
kW
5.27
7.36
10.00
11.40
13.40
Power input “heating”
kW
5.89
7.97
10.00
11.60
13.50
Compressor
Type
Cooling capacity
kW
EER
Heating capacity
COP
Electrical features
Power supply
3/N/ 400V 50Hz
DC Inverter Scroll
DC Inverter Scroll + Standard Scroll
Dimensions and Weight
Height x Width x Length
mm
1 808 x 990 x 750
1 808 x 990 x 751
1 808 x 1 390 x 750
1 808 x 1 390 x 751
1 808 x 1 390 x 752
Weight
kg
240
240
360
360
368
Piping connections
Gas
3/4”
7/8”
1”
1”
1 1/8”
Liquid
3/8”
3/8”
1/2”
1/2”
1/2”
10
10
23
26
Refrigerant charge
Type
kg
R410A
10
10
10
Piping length / Height difference
Max. piping length
m
175
Max. height difference
m
50
Max. number of indoor units
13
16
19
56/57
VRF Systems
Amazon Standard Ambient VRF System
YV2V 050 to 135
YV2V Technical features - Outdoor units with two module combinations
Model
YV2VYH050KAS YV2VYH056KAS YV2VYH061KAS YV2VYH068KAS YV2VYH073KAS YV2VYH078KAS YV2VYH085KAS YV2VYH090KAS
Module combinations
1x YV2VYH022
1x YV2VYH028
2x YV2VYH028
1x YV2VYH028
1x YV2VYH033
1x YV2VYH028
1x YV2VYH040
1x YV2VYH028
1x YV2VYH045
2x YV2VYH040
1x YV2VYH040
1x YV2VYH045
2x YV2VYH045
Cooling capacity
kW
50.6
56.0
61.5
68.0
73.0
78.5
85.0
90.0
Heating capacity
kW
56.5
63.0
69.0
76.5
81.5
90.0
95.0
100.0
Noise level at 1 m
dB(A)
60
60
61
61
61
62
62
62
Electrical features
Power supply
3/N/ 400V 50Hz
Power input “cooling”
kW
12.63
14.72
17.36
18.76
20.76
22.80
24.80
26.80
Power input “heating”
kW
13.86
15.94
17.97
19.57
21.47
23.20
25.10
27.00
Dimensions and Weight
Height x Width x Length
mm
Weight
kg
1808 x 1980 x 1501 1808 x 1980 x 1502 1808 x 2380 x 1501 1808 x 2380 x 1502 1808 x 2380 x 1503 1808 x 2780 x 1502 1808 x 2780 x 1503 1808 x 2780 x 1504
480
480
600
600
608
720
728
736
50
53
Piping size between the outdoor unit and the first branch
Gas
1 1/8”
1 3/8”
Liquid
5/8”
3/4”
Refrigerant piping
Max. piping length
m
175
Max. height difference
m
50
Connection between modules (out. groups)
Max. number of indoor units
HZG - 20A
29
33
36
39
43
46
YV2V Technical features - Outdoor units with three module combinations
Model
YV2VYH096KAS YV2VYH101KAS YV2VYH106KAS YV2VYH113KAS YV2VYH118KAS YV2VYH123KAS YV2VYH130KAS YV2VYH135KAS
Module combinations
2x YV2VYH028
1x YV2VYH040
2x YV2VYH028
1x YV2VYH045
1x YV2VYH028
2x YV2VYH040
1x YV2VYH028
1x YV2VYH040
1x YV2VYH045
1x YV2VYH028
2x YV2VYH045
1x YV2VYH033
2x YV2VYH045
1x YV2VYH040
2x YV2VYH045
3x YV2VYH045
Cooling capacity
kW
96.0
101.0
106.5
113.0
118.0
123.5
130.0
135.0
Heating capacity
kW
108.0
113.0
121.5
126.5
131.5
137.5
145.0
150.0
Noise level at 1 m
dB(A)
63
63
63
63
63
64
64
64
Electrical features
Power supply
3/N/ 400V 50Hz
Power input “cooling”
kW
26.12
28.12
30.16
32.16
34.16
36.80
38.20
40.20
Power input “heating”
kW
27.54
29.44
31.17
33.07
34.97
37.00
38.60
40.50
Dimensions and Weight
Height x Width x Length
mm
Weight
kg
1808 x 3370 x 2253 1808 x 3370 x 2254 1808 x 3770 x 2253 1808 x 3770 x 2254 1808 x 3770 x 2255 1808 x 4170 x 2254 1808 x 4170 x 2255 1808 x 4170 x 2256
840
848
960
968
976
1 096
1 096
1 104
64
64
64
64
Piping size between the outdoor unit and the first branch
Gas
1 3/8”
Liquid
3/4”
Refrigerant piping
Max. piping length
m
175
Max. height difference
m
50
Connection between modules (out. groups)
Max. number of indoor units
HZG - 30A
56
59
63
64
york air-conditioning products
VRF Heat recovery system
YV2V 024 to 045
YV2V 3 Pipes Technical features - Single module outdoor unit
Model
YV2VYT024KAS-D-X
YV2VYT029KAS
YV2VYT035KAS
YV2VYT042KAS
YV2VYT045KAS
23.9
29.3
35.1
41.7
45.0
4.02
3.84
3.82
3.42
3.23
kW
26.5
32.8
39.2
46.8
50.7
4.3
4.1
4.2
4.1
3.8
Air flow
m3/h
11.100
11.100
14.100
14.100
14.100
Sound Pressure Level at 1 m
dB(A)
57
57
60
60
60
Power input “cooling”
kW
6.0
7.6
9.2
12.2
14.0
Power input “heating”
kW
6.2
8.0
9.2
11.4
13.4
Compressor
Type
Cooling capacity
kW
EER
Heating capacity
COP
Electrical features
Power supply
3/N/ 400V 50Hz
DC Inverter Scroll
DC Inverter Scroll + Standard Scroll
Dimensions and Weight
Height x Width x Length
mm
1 808 x 990 x 750
1 808 x 990 x 750
1 808 x 1 390 x 750
1 808 x 1 390 x 750
1 808 x 1 390 x 750
Weight
kg
240
240
368
368
368
3/4” / 3/4”
7/8” / 3/4”
1” / 7/8”
1” / 7/8”
1 1/8” / 1”
3/8”
3/8”
1/2”
1/2”
1/2”
10
10
23
26
Piping connections
Gas
Liquid
Type
Refrigerant charge
R410A
kg
10
10
10
Piping length / Height difference
Max. piping length
m
175
Max. height difference
m
50
Max. number of indoor units
13
16
19
Combination of modular outdoor units
HP
Capacity
8
10
12
15
16
18
20
22
24
26
28
30
32
34
36
38
40
42
44
46
48
Coolin kW
23.9
29.3
35.1
41.7
45.0
53.2
58.6
64.4
71.0
74.3
83.4
86.7
90.0
100.3
103.6
112.7
116.0
119.3
125.1
131.7
135.0
Heating kW
26.5
32.8
39.2
46.8
50.7
59.3
65.6
72.0
79.6
83.5
93.6
97.5
101.4
112.4
116.3
126.4
130.3
134.2
140.6 148.2
152.1
13
16
19
23
26
29
33
36
39
43
46
50
53
56
59
63
64
64
Maximum indoor units
64
Appearance
Technical features - Heat recovery valve box
Model
VB1-112A
VB1-180A
VB1-280A
Capacity
Power supply
Total Capacity Index of Indoor Units
3/N/ 400V 50Hz
kW
Number of Connectable Indoor Units
≤ 11.2
> 11.2 & ≤ 18.0
> 18.0 & ≤ 28.0
Max. 5
Max. 8
Max. 8
3/8”
Piping connection
Liquid pipe - Connect to indoor unit
mm
3/8”
3/8”
Gas pipe -Connect to indoor unit
mm
5/8”
5/8”
7/8”
Liquid pipe-Connect to outdoor unit
mm
3/8”
3/8”
3/8”
Suction pipe-Connect to outdoor unit
mm
5/8”
5/8”
1”
High pressure gas pipe-Connect to outdoor unit
mm
1/2”
5/8”
3/4”
mm
180 x 400 x 300
180 x 400 x 300
180 x 400 x 300
12
12
13
Dimensions & Weight
Height x Width x Length
Weight
kg
64
64
58/59
VRF Systems
VRF Heat recovery system
Heat recovery valve box scheme
Outdoor unit side (3 pipes)
Indoor unit side (2 pipes)
Gas pipe
HP gas pipe
Liquid pipe
Suction pipe
Liquid pipe
Cooling and heating synchronously in one system
Heat recovery system can achieve cooling and heating synchronously in one system by valve box device.
2-Pipe system
Cooling and heating in two systems
Heat recovery system (3-Pipe)
Cooling and heating in one systems
Heat Recovery, More Energy-saving
The surplus heat of some indoor units’ condensation can be used for other indoor units for evaporation.
Comparing with traditional Air Conditioning system, save at least 15% energy.
york air-conditioning products
VRF Technical features indoor units
High wall (EXV integrated)
Model
Cooling
Capacity
Heating
Air flow
Noise level at 1 m H / M / L
Power supply
Electrical
features
Current
HxWxD
Dimensions
and Weight
Weight
Gas
Piping
Liquid
kW
kW
m3/h
dB(A)
V/Ph/Hz
A
mm
kg
YVHVXH022
YVHVXH028
YVHVXH036
YVHVXH045
YVHVXH056
YVHVXH071
2.2
2.5
2.8
3.2
3.6
4.0
4.5
5.0
5.6
6.3
7.1
8.0
37 / 33 / 31
37 / 34 / 31
600
800
41 / 36 / 33
41 / 36 / 33
230 / 1 / 50 + N + E
43 / 39 / 34
0.31
265 x 938 x 187
10.9
1/2”
1/4”
48 / 39 / 37
0.41
299 x 1 046 x 239
13
5/8”
3/8”
Cassette
Model
Cooling
Capacity
Heating
Air flow
Noise level at 1 m H / M / L
Power supply
Electrical
features
Current
HxWxD
Dimensions
and Weight
Weight
HxWxD
Panel
Weight
Gas
Piping
Liquid
kW
kW
m3/h
dB(A)
V/Ph/Hz
A
mm
kg
mm
kg
YVKVXH028
YVKVXH036
YVKVXH045
YVKVXH056
2.8
3.2
700
32 / 30 / 29
3.6
4.0
4.5
5.0
5.6
6.3
650
32 / 30 / 29
33 / 30 / 29
0.47
260 x 570 x 570
17
60 x 700 x 700
2.8
3/8”
1/4”
1/2”
1/4”
YVKVXH071
YVKVXH080
YVKVXH090
7.1
8.0
9.0
8.0
9.0
10.0
1 200
34 / 32 / 30
35 / 34 / 31
37 / 35 / 31
37 / 35 / 31
230 / 1 / 50 + N + E
0.67
240 x 840 x 840
30
80 x 950 x 950
6
5/8”
3/8”
YVKVXH112
YVKVXH140
11.2
12.5
1 800
37 / 35 / 31
14.0
16.0
44 / 40 / 36
0.76
295 x 840 x 840
38
Convertible console floor/ceiling
Model
Cooling
Capacity
Heating
Air flow
Noise level at 1 m H / M / L
Power supply
Electrical
features
Current
HxWxD
Dimensions
and Weight
Weight
Gas
Piping
Liquid
kW
kW
m3/h
dB(A)
V/Ph/Hz
A
mm
kg
YVFVXH028
YVFVXH036
YVFVXH045
YVFVXH056
YVFVXH071
YVFVXH112
YVFVXH140
2.8
3.2
3.6
4.0
4.5
5.0
800
48 / 46 / 44
5.6
6.3
7.1
8.0
11.2
12.5
14.0
16.0
2 040
50 / 48 / 46
53 / 51 / 49
230 / 1 / 50 + N + E
0.3
655 x 990 x 199
38.3
1/2”
1/4”
3/8”
1/4”
1.8
700 x 1 580 x 240
54
5/8”
3/8”
Console
Model
Cooling
Capacity
Heating
Air flow
Noise level at 1 m H / M / L
Power supply
Electrical
features
Current
HxWxD
Dimensions
and Weight
Weight
Gas
Piping
Liquid
kW
kW
m3/h
dB(A)
V/Ph/Hz
A
mm
kg
YV5VXH022
YV5VXH028
YV5VXH036
YV5VXH056
2.2
2.5
2.8
3.2
3.6
4.0
520
5.0
6.0
580
48 / 46 / 42
460
43 / 39 / 36
230 / 1 / 50 + N + E
0.44
640 x 720 x 255
18
1/2”
1/4”
60/61
VRF Systems
VRF Technical features indoor units
Low and Medium Static Pressure Duct
Model
Low Static Pressure
Medium Static Pressure
YVDVXH022 YVDVXH028 YVDVXH036 YVDVXH045 YVDVXH056 YVDVXH071 YVEVXH056 YVEVXH071 YVEVXH080 YVEVXH090 YVEVXH112 YVEVXH114
Cooling
Heating
Air flow
Noise level at 1 m H / M / L
External static presure
Power supply
Electrical features
Current
HxWxD
Dimensions
and Weight
Weight
Gas
Piping
Liquid
Capacity
kW
kW
m3/h
dB(A)
Pa
V/Ph/Hz
A
mm
kg
2.2
2.5
2.8
3.2
400
3.6
4.0
500
35 / 32 / 30
4.5
5.0
850
5.6
6.3
7.1
8.0
5.6
7.1
7.1
8.0
1 200
1 250
39 / 37 / 35
8.0
9.0
9.0
10.0
11.2
12.5
14.0
16.0
2 100
44 / 40 / 36
1 900
43 / 37 / 35
0 ~ 20
50 ~ 96
80 ~ 120
1.1
300 / 1 180 / 743
39
2.2
270 / 1 135 / 742
50
230 / 1 / 50 + N + E
0.27
220 / 610 / 500
15
3/8”
1/4”
0.38
16
25
1/2”
1/4”
0.55
220 / 1 105 / 500
28
5/8”
3/8”
1/2”
1/4”
5/8”
3/8”
High Static Pressure Duct
Model
Cooling
Capacity
Heating
Air flow
Noise level at 1 m H / L
External static presure
Power supply
Electrical features
Current
HxWxD
Dimensions
and Weight
Weight
Gas
Piping
Liquid
YVGVXH056
YVGVXH071
YVGVXH080
YVGVXH090
YVGVXH112
YVGVXH140
YVGVXH226
YVGVXH280
5.6
6.3
7.1
8.0
1 500
42 / 40
8.0
9.0
9.0
10.0
1 560
11.2
12.5
1 600
45 / 40
14.0
16.0
2 100
22.6
25.0
28.0
31.6
kW
kW
m3/h
dB(A)
Pa
V/Ph/Hz
A
mm
kg
4 050
54 / 49
100
230 / 1 / 50 + N + E
2.55
360 x 1 350 x 875
62
5/8”
3/8”
2.05
360 x 970 x 875
48
1/2”
1/4”
5.05
360 x 1 610 x 840
92
1”
3/8”
Fresh Air Unit
Model
Cooling
Capacity
Heating
Air flow
Noise level at 1 m High speed
External static presure
Electrical features Power supply
HxWxD
Dimensions
and Weight
Weight
Gas
Piping
Liquid
kW
kW
m3/h
dB(A)
Pa
V/Ph/Hz
mm
kg
YV4VXH140
YV4VXH226
YV4VXH280
14.0
8.9
1 600
48
22.6
15.2
2 300
28.0
17.8
2 800
55
100
230 / 1 / 50 + N + E
360 x 1 350 x 875
62
5/8”
3/8”
360 x 1 750 x 840
120
1”
3/8”
Heat Recovery Ventilator
Model
Air flow
External static presure
Power supply
HxWxD
Dimensions
and Weight
Weight
m3/h
Pa
V/Ph/Hz
mm
kg
YV6VXH015
YV6VXH026
YV6VXH080
YV6VXH100
150
50
200
60
800
80
1 000
100
276x940x685
276x940x686
230 / 1 / 50 + N + E
28.7
387x1227x1115
387x1227x1116
85.5
york air-conditioning products
Controllers & BMS
YR-H71 Wireless Controller
Elegant and slim design, LCD display, 4 Operation modes (Cool/Dry/Heat/Fan),
Timer ON/OFF setting up to 24 Hr., Temperature control range, Fan speed selection.
Standard for High Wall and Console, optional for Duct, Cassette and Floor Ceiling.
YR-E14 Wired Controller
Exclusive design, Big LCD display, 4 Operation modes (Cool/Dry/Heat/Fan),
Temperature setting, Timer setting,Fan speed selection, Group controller up to 16 indoor units.
Standard for Duct, Cassette and Floor Ceiling. No optional for High Wall and Console.
YCZ-A003 Touch Screen Central Controller
Max. 128 indoor units control.
Single or all query and control, such as ON/OFF/Mode setting/Temp setting/ Fan setting ect.
Mode lock function, Blue light background, LCD display screen.
HCM-01 Central Controller With Monitor Software
Max. 128 indoor units control.
Single or all query and control, such as ON/OFF/Mode setting/Temp setting/ Fan setting ect.
Mode lock function, Blue light background, Software Monitoring on any PC.
IGU05 Touch Screen Central Controller Translator
Translating protocol between home bus and RS485.
Connecting with one outdoor (combination model also regard as one) system.
Work with Touch Screen Central Controller
IGU02 BacNet/IP Translator
IGU06 LonWorks Translator
Translating protocol between home bus
and RS485.
Connecting with one outdoor (combination
model also regard as one) system.
Work with Central Controller with Monitor
Software and BacNet/IP Converter.
Translating protocol between home bus
and RS485.
Connecting with one outdoor (combination
model also regard as one) system.
Work with LonWorks Converter.
HCM-03 BacNet/IP Converter
IGU07 LonWorks Converter
Max. 72 indoor units control.
Connect A/C system to BMS by BacNet/IP
protocol.
Max. 32 indoor units control.
Connect A/C system to BMS by
LONWORKS protocol.
62/63
VRF Systems
VRF System - System Diagram
Possible to connect to JCI Metasys
Piping accessories
Model
FQG-B335A
FQG-B506A
FQG-B730A
FQG-B1350A
HZG-20A
HZG-30A
FQG-R335A
FQG-R506A
FQG-R730A
FQG-R1350A
HZG-R20A
HZG-R30A
System
Name
Function
Application
2 pipes
2 pipes
2 pipes
2 pipes
2 pipes
2 pipes
3 pipes
3 pipes
3 pipes
3 pipes
3 pipes
3 pipes
Indoor mainfold pipe
Indoor mainfold pipe
Indoor mainfold pipe
Indoor mainfold pipe
Outdoor branch pipe
Outdoor branch pipe
Indoor mainfold pipe
Indoor mainfold pipe
Indoor mainfold pipe
Indoor mainfold pipe
Outdoor branch pipe
Outdoor branch pipe
Refrigerant distribution
Refrigerant distribution
Refrigerant distribution
Refrigerant distribution
Refrigerant gathering
Refrigerant gathering
Refrigerant distribution
Refrigerant distribution
Refrigerant distribution
Refrigerant distribution
Refrigerant gathering
Refrigerant gathering
Total indoor units capacity < 33.5 kW
33.5 kW ≤ Total indoor units capacity < 50.6 kW
50.6 kW ≤ Total indoor units capacity < 72 kW
73 kW ≤ Total indoor units capacity
2 module combinations
3 module combinations
Total indoor units capacity < 33.5 kW
33.5 kW ≤ Total indoor units capacity < 50.6 kW
50.6 kW ≤ Total indoor units capacity < 72 kW
73 kW ≤ Total indoor units capacity
2 module combinations
3 module combinations
YORK VRF System
A
The YORK system with DC Inverter Scroll is working
like the VRF principle and offers you economical airconditioning system for projects, which are requiring more
capacity than the normal split and multi split solutions.
B
C
The lengths for the connecting tubes between the indoor
and outdoor have been prolonged, which brings you more
flexible solutions for complex air-conditioning projects.
A – Maximum single way pipe length : 175 m.
B – Maximum difference in height : 50 m.
C–M
aximum difference in height between 2 indoor units : 15 m.
About Johnson Controls
Johnson Controls delivers products, services and solutions that increase energy efficiency and lower operating
costs in buildings for more than one million customers.
Operating from 500 branch offices in more than 150 countries, the company is a leading provider of equipment,
controls and services for heating, ventilating, air-conditioning, refrigeration and security systems. Johnson Controls
is involved in more than 500 renewable energy projects including solar, wind and geothermal technologies.
Its solutions have reduced carbon dioxide emissions by 13.6 million metric tons and generated savings of $7.5
billion since 2000. Many of the world’s largest companies rely on Johnson Controls to manage 1.5 billion square
feet of their commercial real estate.
PUBL-7393
© 2014 Johnson Controls, Inc.
www.johnsoncontrols.com
E-CAT-MIN-G2014
http://www.johnsoncontrols.co.uk
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement

Languages