Quicklynks | T55 | Server Paper Configurator Guide

Januar y 2000
Server Paper Configurator Guide
IBM Netfinity Ser vers
Racks
Storage Enclosures
Fibre Channel Solutions
Options
© International Business Machines Corporation 1999
IBM Personal Systems Group
Department K0LA
3039 Cornwallis Road
Research Triangle Park, NC 27709
Printed in the United States of America
1-00
All Rights Reserved
Printed on recycled paper containing
10% recovered post-consumer fiber.
G326-8034-12
Information Sources .................................................. 2
IBM Netfinity EXP200 (35301RU) Configurator........88
Server Product Positioning
.................................... 4
IBM Netfinity Fibre Channel Solutions .....................90
Server Selection Guidance
.................................. 6
IBM Netfinity NetBAY3/NetBAY3E Stackable
Enclosures
......................................................104
TABLE OF CONTENTS
Table of Contents
IBM Netfinity 1000 Configurator .............................. 10
IBM Netfinity Rack Cabinet and Options ...............106
IBM Netfinity 3000 Configurator ............................. 14
Appendix A: Tape Drive Attributes .......................110
IBM Netfinity 3500 M10 Configurator ...................... 18
Appendix B: Tape Library Attributes ....................111
IBM Netfinity 4000R Configurator............................ 24
Appendix C: UPS Runtime Estimate (minutes) ...112
IBM Netfinity 5000 Configurator .............................. 28
Appendix D: Cables - Storage Units - Controllers 114
IBM Netfinity 5500 Configurator .............................. 36
Appendix E: IBM Serial I/O ...................................116
IBM Netfinity 5500 M10 Configurator ...................... 44
Important Notes .....................................................117
IBM Netfinity 5500 M20 Configurator ...................... 52
IBM Netfinity 5600 Configurator .............................. 60
IBM Netfinity 7000 M10 Configurator ...................... 68
IBM Netfinity 8500R Configurator............................ 76
IBM External Storage Expansion Unit Overview ..... 84
IBM Netfinity EXP15 (3520-2RU) Configurator ........ 86
1
Information Sources
Canada
Audience
Where to go
How to get
Server Paper Configurator Guide
Customers
www.ibm.com/pc/ca/netfinity/tech_library.html
Business Partners
www.ibm.com/pc/partner/ca
Select “Technical Info.”
Select “Sales Tools” and then “Marketing Essentials”. User ID and Password required.
IBM Employees
Marketing Essentials
By Brand category --> IBM Netfinity or By Brand category --> PC Configurator
Feedback
www.ibm.com/pc/partner/ca/feedback.html
Netfinity Rack Configurator
Customers
www.ibm.com/pc/ca/netfinity/tech_library.html
Business Partners
www.ibm.com/pc/partner/ca
Select “Technical Info.”
Select “Sales Tools” and then “Marketing Essentials”. User ID and Password required.
IBM Employees
Marketing Essentials
By Brand category --> IBM Netfinity or By Brand category --> PC Configurator
Feedback
E-mail ibm_netfinity_rack_configurator@vnet.ibm.com
Latest Product & Technical Information
Customers
www.ibm.com/pc/ca/netfinity or call 1-800-426-2255
Business Partners
www.ibm.com/pc/partner/ca or call the PSMT
IBM Employees
Marketing Essentials
User ID and Password required
By Brand category --> IBM Netfinity or By Brand category --> PC Configurator
Latin America
Server Paper Configurator Guide
Customers
www.ibm.com/pc/us/netfinity/tech_library.html
Business Partners
www.la.pc.ibm.com (Contact country channel
representative for PIN number or to request a CD)
IBM Employees
Marketing Essentials
Feedback
E-mail laconfig@us.ibm.com
Select “Configuration Tools”
Spanish - Select “Asociados” then “Herramientas de Ventas” and finally, “Marketing Essentials”.
User ID and Password are required. By Brand category --> IBM Netfinity or PC Configurator
Portuguese - Brazil select “Portugues” then “Business Partners” and finally “Produtos e Servicos”.
User ID and Password are required. By Brand category --> IBM Netfinity or PC Configurator
By Brand category --> IBM Netfinity or By Brand category --> PC Configurator
Netfinity Rack Configurator
Customers
www.ibm.com/pc/us/netfinity/tech_library.html
Business Partners
Marketing Essentials
Select “Configuration Tools”
By Brand category --> IBM Netfinity or By Brand category --> PC Configurator
IBM Employees
Marketing Essentials
By Brand category --> IBM Netfinity or By Brand category --> PC Configurator
Feedback
E-mail ibm_netfinity_rack_configurator@vnet.ibm.com
OrderBUILDER1 (updated bi-weekly)
Business Partners
www.la.pc.ibm.com (Contact country channel
representative for PIN number or to request a CD)
IBM Employees
Marketing Essentials
Feedback
E-mail laconfig@us.ibm.com
Spanish - Select “Asociados” then “Herramientas de Ventas” and finally, “Marketing Essentials”.
User ID and Password are required.
Portuguese - Brazil select “Portugues” then “Business Partners” and finally “Produtos e Servicos”.
User ID and Password are required.
By Brand category --> IBM Netfinity or By Brand category --> PC Configurator
Latest Product & Technical Information
Customers
www.la.pc.ibm.com
Business Partners
www.la.pc.ibm.com (Contact country channel
representative for PIN number or to request a CD)
IBM Employees
Marketing Essentials
Spanish - Select “Asociados” then “Herramientas de Ventas” and finally, “Marketing Essentials”.
User ID and Password are required.
Portuguese - Brazil select “Portugues” then “Business Partners” and finally “Produtos e Servicos”.
User ID and Password are required.
By Brand category --> IBM Netfinity or By Brand category --> PC Configurator
1. OrderBUILDER has features that are unique to a geographical region and should therefore be downloaded from a source intended for use in that region.
***See Next Page for United States and Additional URLs***
2
United States
Audience
Where to go
How to get
Server Paper Configurator Guide
Customers
www.ibm.com/pc/us/netfinity/tech_library.html
Select “Configuration Tools”
Business Partners
www.pc.ibm.com/partner/us/
Select Sales Tools, then Marketing Essentials, then IBM PC Server--> Paper Configurator.
User ID and Password required.
IBM Employees
Marketing Essentials
By Brand category --> IBM Netfinity or By Brand category --> PC Configurator
Feedback
www.ibm.com/pc/partner/us/feedback.html
Netfinity Rack Configurator
Customers
www.ibm.com/pc/us/netfinity/tech_library.html
Select “Configuration Tools”
Business Partners
www.pc.ibm.com/partner/us/
Select Sales Tools, then Marketing Essentials, then IBM PC Server--> Rack Configurator.
User ID and Password required.
IBM Employees
Marketing Essentials
By Brand category --> IBM Netfinity or By Brand category --> PC Configurator
Feedback
E-mail ibm_netfinity_rack_configurator@vnet.ibm.com
Customers
INFORMATION SOURCES
OrderBUILDER1 (updated bi-weekly)
www.ibm.com/pc/us/orderbuilder
Business Partners
www.ibm.com/pc/partner/us
Select Sales Tools, then OrderBUILDER. User ID and Password required.
Marketing Essentials
By Brand category --> IBM Netfinity or By Brand category --> PC Configurator
w3.pc.ibm.com/catalog/install.html
Intranet: Select Sales Automation then OrderBUILDER
IBM Employees
Feedback
E-mail pcconfig@us.ibm.com
Latest Product & Technical Information
Customers
www.ibm.com/pc/us/netfinity or call 1-800-772-2227
Business Partners
www.pc.ibm.com/partner/us/ or call 1-800-426-7763
Select Products & Services; User ID and Password required
IBM Employees
Marketing Essentials
By Brand category --> IBM Netfinity or By Brand category --> PC Configurator
Additional URLs
Audience
Where to go
How to get
Technical spec sheets (PSREF)
www.ibm.com/pc/us/netfinity/tech_library.html
Select “Technical spec sheets(PSREF)”
Clustering (US, LA)
www.ibm.com/pc/us/netfinity/clustering.html
Select desired category or Server
Clustering (CAN)
www.ibm.com/pc/ca/netfinity/clustering.htm
Select desired category or Server
Benchmark Results
www.ibm.com/pc/us/techlink/srvperf.html
Select desired category or Server
Options/NOS/Server compatibility
www.ibm.com/pc/us/compat
From pulldown select desired category
NOS - Hot-Plug/Failover Support
www.ibm.com/pc/us/compat
From pulldown select “Netfinity Hotplug PCI and Failover Info”.
IBM Storage Products
www.ibm.com/storage
Adobe® Acrobat® Reader V 3.0 or 4.0
www.adobe.com/prodindex/acrobat/readstep.html
Follow instructions.
www.ibm.com/pc/us/netfinity
Select “Support”, “Family”, “Model”, “Downloadable files” and “Advanced Systems
Management”.
Adv. Sys. Mgmt. Adapter Firmware
Flash BIOS Updates
www.ibm.com/pc/support
Enter machine “Type-Model” in Quick Path. Select “Downloadable files” then “BIOS”.
ServeRAID Updates
www.ibm.com/pc/support
Select “Server” in Brand pulldown, “ServeRAID” in Family pulldown and then
“Downloadable files”.
1. OrderBUILDER and ConfigXpert have features that are unique to a geographical region and should therefore be downloaded from a source intended for use in that region.
The information contained in this document has not been submitted to any formal IBM test. The following paragraph does not apply to the
United Kingdom or any country where any such provisions are inconsistent with local law:
INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS PUBLICATION “AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER
EXPRESSED OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE. SOME STATES DO NOT ALLOW DISCLAIMER OF EXPRESS OR IMPLIED WARRANTIES IN CERTAIN TRANSACTIONS.
THEREFORE, THIS STATEMENT MAY NOT APPLY TO YOU. THERE IS NO GUARANTEE THAT IBM WILL MARKET ANY PARTICULAR PRODUCT IN
YOUR COUNTRY.
The use of this information or the implementation of any of these techniques is a customer responsibility and depends on the customer’s ability
to evaluate and integrate them into the customer’s operational environment. While each item may have been reviewed by IBM for accuracy in a
specific situation, there is no guarantee that the same or similar results will be obtained elsewhere. Customers attempting to adapt these
techniques to their own environments do so at their own risk.
The following sample configurations are for illustration only and may not be suitable for any specific customer installation. Contact your IBM
Business Partner or IBM Marketing Representative for assistance with your specific configuration requirements.
Updated 01/01/00
For the latest product & technical information, refer to the Information Sources on pages 1 and 2.
3
Server Product Positioning
Increased Capacity:
85
00
R
Application
Memory
Storage
Slots
Availability Features
55
M 00
10
M
10
00
1
30
00
35
0
10 0
40
0
0R
2
50
00
55
0
0
56
00
55
M 00
20
00
70 10
M
fi
et
N
ty
ni
M
IB
File and
Print
1. Netfinity 1000 is not available in the Americas.
2. Available in the US only.
4
Number of Clients
When in a competitive situation, this table suggests the appropriate IBM Netfinity server to bid against other vendors’ equipment. However, as an IBM business
partner, you may determine that customer specific requirements may make an alternative IBM solution a better choice
High End
Mainstream
IBM 1st
Choice
IBM 2nd
Choice
Compaq
HP
Netfinity
8500R
RS/6000
AS/400
ProLiant 8000,
8500
NetServer 8500
8450
Netfinity 7000
M10
Netfinity 8500R
ProLiant 6400R
6500, 7000
NetServer LXr,
LXr Pro
PowerEdge
6300
Netfinity 5500
M20
Netfinity 7000
M10
ProLiant 5500,
5500R, 6500,
6400R
NetServerLH4/4r
PowerEdge
6300, 6350
Netfinity 5500
M10
Netfinity 5500
M20
ProLiant 3000,
3000R, 5500,
5500R
NetServer LH3,
LH4
PowerEdge
4300, 6350
Netfinity 5600
Netfinity 5500
M10
ProLiant 3000,
3000R
NetServer LH3
PowerEdge
4300, 4350
Netfinity 5500
Netfinity 5600,
5500 M10
ProLiant 3000,
3000R
NetServer LH3
PowerEdge
4300, 4350
Netfinity 5000
Netfinity 5600
ProLiant 1850R, NetServer LHII,
1600, 1600R
LH Pro, LC3, LPr
Netfinity 5000
ProLiant 1850R
NetServer LPr
N/A
Netfinity 3500
M10
Netfinity 4000R2
ProLiant 400,
1600. 1600R
NetServer LHII,
LH Pro, LC3, LPr
PowerEdge
1300
Netfinity 3000
Netfinity 3500
M10
ProSignia 200,
720
ProLiant 400
NetServer E60
PowerEdge
1300
Netfinity 3000
NeoServer
NetServer E60
PowerEdge
1300
Netfinity
4000R2
Entry
Dell
Netfinity 10001
5000R
PowerEdge
2300, 4350
Updated 01/01/00
For the latest product & technical information, refer to the Information Sources on pages 1 and 2.
PRODUCT POSITIONING
1. Netfinity 1000 is not available in the Americas.
2. Available in the US only.
5
Server Selection Guidance
This graph represents general guidelines for selecting the appropriate server based on the number of users that can be supported in a particular application environment.
This chart is for general guidance since each customer environment is unique and is unlikely to be precisely represented by any of the specific applications in the chart, but
by using the chart, a reasonable approximation can be derived. External Storage Units are utilized when internal capacities are exceeded. Utilize the chart by following the
steps outlined on the following page.
These are not published benchmark results. Access http://www.ibm.com/pc/us/techlink/srvperf.html to obtain benchmark data.
Application/
Expectation of
Maximum # of Users
DB Transaction Processing
Select, Update and Delete;
Does not include image or
Decision Support
File and Print
Application is stored locally.
(For server stored applications
- cut number of users in half).
Lotus Notes
10% Power Users 40% Mail
50% Mail & DB
Microsoft Exchange Server
5.5
100% Med Usersl
30 MB Mailbox
SAP 3-Tier Distributed
Ver 4.x
Processing
Sales and Distribution
Application (Minimum of 16-20
Servers)
SAP Central Version 4.x
Processing
Sales and Distribution
Application
(One Server)
High Availability Features
Other Distinquishing
Features
6
Netfinity 10003
Uni-Pentium III
550 MHz/512 KB
# of Users
# of processors
Memory (MB)
# Hard Disk Drives
# RAID Adapters
#Network Connections
# of Users
# of Processors
Memory (MB)
# Hard Disk Drives
# RAID Adapters
# 100Mbps Ethernet
Connections
# of Users
# of Processors
Memory (MB)
# Hard Disk Drives
# RAID Adapters
# Network Connections
# of Users
# of Processors
Memory (MB)
# Hard Disk Drives
# RAID Adapters
# Network Connections
# of Users
# of Processors
Memory (MB)
# Hard Disk Drives
# RAID Adapters
# Network Connections
# Users
# Processors
Memory (MB)
# Hard Disk Drives
# RAID Adapters
# Network Connections
Hot-Swap HDD Bays
Hot-Plug PCI Slots
Hot-Swap Power
Hot-Swap Fans
RAID
Clustering Support
Sys. Mgt. Processor
Max # Processors
Max Memory (MB)
Max Int. Storage (GB)
Max Int. Storage (GB)
with Int. Tape drive
Available PCI Slots
19” Rack Models
NetBAY3x Support
975
1
384
4 to 8
> 1 SCSI
1
1000
1
512
3 to 4
> 1 SCSI
Netfinity 3000 Netfinity 3500 M10 Netfinity 5000
Uni-Pentium III
Dual Pentium III Dual Pentium III
600 MHz/512 KB 600 MHz/512 KB 600 MHz/512 KB
1050
1
384
4 to 8
> 1 SCSI
1
1000
1
512
3 to 4
> 1 SCSI
2500
2
1 GB
24 to 36
>3
1
2000
2
1 GB
16 to 24
2
2500
2
1 GB
24 to 36
>3
1
2000
2
1 GB
16 to 24
2
>2
>2
4
4
525
1
384
3 to 4
> 1 SCSI
>1
500
1
256
3 to 4
> 1 SCSI
>1
N/A
N/A
Opt.
Opt.
1
768
72.8
575
1
384
3 to 4
> 1 SCSI
>1
550
1
384
3 to 4
> 1 SCSI
>1
N/A
N/A
Opt.
Opt.
1
768
72.8
1400
2
1 GB
18
1
>2
1800
2
1 GB
9
1
>1
N/A
104
2
1 GB
12 to 24
>1
1
Opt.
2
1 GB
72.8
1400
2
1 GB
18
1
>2
1800
2
1 GB
9
1
>1
N/A
104
2
1 GB
12 to 24
>1
1
X
X
Opt.
X
X
2
2 GB
91
54.6
54.6
54.6
91
2
-
2
-
5
-
5
X
-
Server Selection Guidance
DB Transaction
Processing
Select, Update and
Delete; Does not
include image or
Decision Support
File and Print
Application is stored
locally. (For server
stored applications cut number of users in
half).
Lotus Notes
10% Power Users 40%
Mail
50% Mail & DB
Microsoft Exchange
Server 5.5
100% Med Users
30 MB Mailbox
SAP 3-Tier
Distributed Ver 4.x
Processing
Sales and Distribution
Application (Minimum
of 16-20 Servers)
SAP Central Version
4.x
Processing
Sales and Distribution
Application
(One Server)
High Availability
Features
Other Distinquishing
Features
Updated 01/01/00
# of Users
# of processors
Memory (MB)
# Hard Disk Drives
# RAID Adapters
#Network Connections
# of Users
# of Processors
Memory (MB)
# Hard Disk Drives
# RAID Adapters
# 100Mbps Ethernet
Connections
# of Users
# of Processors
Memory (MB)
# Hard Disk Drives
# RAID Adapters
# Network Connections
# of Users
# of Processors
Memory (MB)
# Hard Disk Drives
# RAID Adapters
# Network Connections
# of Users
# of Processors
Memory (MB)
# Hard Disk Drives
# RAID Adapters
# Network Connections
# Users
# Processors
Memory (MB)
# Hard Disk Drives
# RAID Adapters
# Network Connections
Hot-Swap HDD Bays
Hot-Plug PCI Slots
Hot-Swap Power
Hot-Swap Fans
RAID
Clustering Support
Sys. Mgt. Processor
Max # Processors
Max Memory (MB)
Max Int. Storage (GB)
Max Int. Storage (GB)
with Int. Tape drive
Available PCI Slots
19” Rack Models
NetBAY3x Support
Netfinity
Netfinity 5500 Netfinity 5500 Netfinity 7000 Netfinity 8500R
5500 Dual Netfinity 5600
M10 Dual
M20 Quad
M10 Quad
Eight-Way
Pentium III Dual Pentium III
Pentium III
Pentium III
Pentium III
Pentium III
550 MHz/512 667 MHz/256 KB Xeon 550 MHz/ Xeon 550 MHz/ Xeon 550 MHz/ Xeon 550 MHz/
KB
512 KB
1024 KB
2048 KB
2 MB
2500
2975
3000
5400
5650
9000
2
2
2
4
4
8
1 GB
4 GB
2 GB
4 GB
4 GB
4 GB
24 to 36
80 to 140
24 to 36
80 to 140
80 to 140
180 to 250
>4
>3
>4
>5
>6 or Fibre
>3
1
2 to 3
1
2 to 3
2 to 3
2 to 3
2000
2100
2400
2500
5000
6000
2
2
2
2
2
3-4
1 GB
1 to 2 GB
1 to 2 GB
1 to 2 GB
3 to 4 GB
4 GB
16 to 24
20 to 30
20 to 30
20 to 30
50 to 90
75 to 150
>4 or Fibre
2
2
2
2
>4
4
4
4
4
8
10
1475
2
1 GB
18
1
>2
1650
2
1 GB
9
1
>1
-
98
2
1 GB
12 to 24
>1
1
X
X
X
X
X
X
X
2
1 GB
109, 4731
1740
2
3 GB
20 to 30
2
>1
2100
2
1.5 GB
12
2
>1
1800
2
1-2 GB
24 to 36
>2
1
122
2
1-2 GB
12 to 24
>1
1
X
X
X
X
Opt.
X
X
2
4 GB
109
1975
2
2 GB
10 to 20
2
>1
2400
2
1.5 GB
16
2
>1
1700
2
1 GB
24 to 36
>2
1
100
2
1 GB
12 to 24
>1
1
X
X
X
X
X
X
X
2
2 GB
109, 4731
3500
4
3 GB
20 to 30
2
>1
4300
4
2 GB
24
2
>2
3150
4
2-4 GB
48 to 60
>3
1
220
4
>2 GB
24 to 36
>2
1
X
X
X
X
X
X
X
4
4 GB
109, 4731
3650
4
3 GB
20 to 30
2
>1
4500
4
3 GB
30
>2
>2
3350
4
>4 GB
48 to 60
>3
1
245
4
>2 GB
24 to 36
>2
1
X
X
X
X
Opt.
X
X
4
8 GB
72.8
5800
8
4 GB
30 to 40
>3
>2
7000
8
4 GB
36
>3
>2
5100
8
>4 GB
48 to 60
>3
1
375
8
>4 GB
24 to 36
>2
1
X
X
X
X
Opt.
X
X
8
16 GB
72.8
109, 4731
109
109, 4731
109, 4731
N/A
N/A
6
X
X
5
X
-
6
X
X
5
X
X
12
X
X2
12
X
X2
N/A
For the latest product & technical information, refer to the Information Sources on pages 1 and 2.
SERVER SELECTION
GUIDANCE
Application/
Expectation of
Maximum # of
Users
7
1. With a single Netfinity EXP15 Storage unit installed in the standard NetBAY3 included with tower models.
2. With a Rack-to-Tower Conversion Kit installed.
3. Netfinity 1000 is not available in the Americas.
Procedure for Server Selection Guidance Chart
File and Print numbers are Novell Netware-based with all others based on Microsoft Windows NT. Other Networking Operating System (NOS) results could vary.
Extensive SAP sizings are available from IBM/SAP Competency Centers. Contact your IBM Marketing Representative for additional information.
Step 1: Determine which application (row) most closely represents the customer’s environment.
Step 2: Move from left to right along the row (chosen in Step 1) noting which columns contain numbers that are equal to or greater than the maximum customer’s
planned number of users.
Step 3: Move up the columns (chosen in Step 2) to the top row to determine which IBM Netfinity or PC Servers should be considered as possible solutions.
Step 4: Evaluate other features such as storage, memory capacity, high availability components, number of available expansion slots, etc., which are unique to each
server, in order to determine which is the most appropriate to recommend.
For your reference, configuration information corresponding to the number of users is also provided.
8
SERVER SELECTION
GUIDANCE
Updated 01/01/00
For the latest product & technical information, refer to the Information Sources on pages 1 and 2.
9
IBM Netfinity 1000 Configurator
)
r
VD
)
,L
il)
so
s)
)
)
)
D
s
n
I
ax
d
va
ax
ax , Fa
ce
ar
/M
RA
l/A
)
o
M
M
d
/
r
/
,
a
D
td
M
n
d
t
d
P
a
t
D
S
t
a
r
o
M
(
t
t
S
lt
(T
(S s, H
)
DI
en
,S
s(
ive
t
ys
Hz
l, U
m
ity
al
=R
or
Dr
(M
n t , S lo
Ba
ua
ge
on
B) x) R
ss
k
i
a
t
a
D
d
e
t
a
K
il)
s
r
il)
n
a
e
r(
ne
di
.(
Qu
Di
ee
oc
va
va
Op
M a her
r
lle
ly Pow
he td/M
Pr
E)
Me
Sp
l/A
rd
r
l/A
y(
o
p
c
f
t
D
m
a
a
r
r
o
a
c
(
e
be
I
p
S
t
a
t
e
(
o
H
u
nt
ct
p
C
bl
ro
m
an
dE
st
y(
To
ss
(To
al
Fa
va
r S wa
Co
be
ar
nd
OM
Nu
:(
or
Sy
CC
s:
ce
rn
-R
bo
ys
SI
rt
mo
du
we ot-S
v.
rm
u m 2 E em
ot
ro
te
a
D
l
n
a
o
e
e
d
C
o
n
P
N
L
S
M
P
I
C
B
F
P
A
O
S
R
H
R
8477-11Y4
4002
1/1
512
64/768 MB
Tower
1/1
-
-
-
10/100
U
4/2
0/72.8 GB
8477-21Y4
5003
1/1
512
64/768 MB
Tower
1/1
-
-
-
10/100
U
4/2
8477-31Y4
5503
1/1
512
64/768 MB
Tower
1/1
-
-
-
10/100
U
4/2
32X-14X
6/4
6/5
0/72.8 GB
32X-14X
6/4
6/5
0/72.8 GB
40X-17X
6/4
6/5
1. Variable read rate. Actual playback speed will vary and is often less than the maximum possible.
2. Intel Pentium II processor with 100 MHz access to memory.
3. Intel Pentium III processor
4. Netfinity 1000 is not available in the Americas.
Netfinity 1000 Processor Upgrades
Part Number
Processor Upgrades with 512KB Cache
Processor Speed Upgrade1
36L9673
Netfinity 500 MHz/512 KB Upgrade with Pentium III Processor
All 1xY
33L5112
Netfinity 550 MHz/512 KB Upgrade with Pentium III Processor
All 1...2xY
1. Requires removal of the standard processor. A maximum of one processor may be installed. Upgrades may require a BIOS update. To obtain the latest Flash BIOS, access
www.ibm.com/pc/support and enter machine “Type-Model” in Quick Path. Select “Downloadable files” and then “BIOS”.
Netfinity 1000 Memory
Total Memory
DIMM Socket
64 MB
N/A
64 MB DIMM Standard
DIMM Socket
128 MB
1 x 01K1130
DIMM Socket
192 MB
1 x 01K1131
256 MB
1 x 01K1131, 1 x 01K1130
Memory Description
320 MB
2 x 01K1131
01K1133
32 MB 100 MHz ECC SDRAM DIMM
384 MB
3 x 01K11311
01K1130
64 MB 100 MHz ECC SDRAM DIMM
512 MB
2 x 01K11321
01K1131
128 MB 100 MHz ECC SDRAM DIMM
768 MB (max)
3 x 01K11321
01K1132
256 MB 100 MHz ECC SDRAM Registered
RDIMM1
Part Number
1. P/N 01K1132 is a registered DIMM and is not compatible with 01K1130, 01K1131, or
01K1133. Installation of this RDIMM requires replacement of the standard DIMM.
10
All Models
32 MB
This table does not represent all possible memory configurations.
1. Replace standard DIMM.
Total
Internal
Storage1
CD-ROM
Bay 2
All Models
0 GB
Standard
9.1 GB
1 x 20L0553
18.2 GB
2 x 20L0553 or 1 x 20L0554
Bay 3
27.3 GB
3 x 20L0553
Diskette
36.4 GB
4 x 20L0553 or 2 x 20L0554
45.5 GB
2 x 20L0554, 1 x 20L0553
Bay 5
Bay 6
IBM NETFINITY 1000
Netfinity 1000 Hard Disk Drive (HDD) Storage
54.6 GB
3 x 20L0554
63.7 GB
3 x 20L0554, 1 x 20L0553
72.8 GB (max) 4 x 20L0554
This table does not represent all possible hard drive configurations.
1. Total Internal Storage listed is within + 0.2 GB unless otherwise noted.
Bay
Form
Factor
Height
Front
Access
Usage
Part
Number
Description
1
5.25”
HH
yes
IDE CDROM
2
5.25”1
HH
yes
open
20L0553
9.1 GB Wide Ultra2 SCSI HDD1
7200
SL
2,3,5,6
4
3
3.5”
SL
yes
open
20L0554
18.2 GB Wide Ultra2 SCSI HDD1
7200
SL
2,3,5,6
4
Bays
Max.
Supported Qty.
Internal Hard Disk Drives (HDD)
External Storage Expansion Units2
4
3.5”
SL
yes
diskette
5
3.5”
SL2
no
open
35301RU
Netfinity EXP200 Storage Expansion Unit
6
3.5”
SL2
no
open
37L5857
Netfinity EXP200 Rack-to-Tower Conversion Kit
1. A 3.5” conversion kit is standard in Bay 2 for installation of 3.5”
hard disk drives.
2. Two slim-line bays can be combined to support a single halfhigh device.
RPM Height
Form Factor
Rack (3U)
-
1. Performs as a Wide Ultra SCSI device when attached to the standard or an optional Wide Ultra SCSI adapter or when
sharing a cable with a non-Ultra2 device.
2. Not supported by the onboard external SCSI port. Select an optional SCSI controller then refer to see Appendix D:
Cables-Storage Units-Controllers to confirm the controller supports the desired External Storage Expansion Unit and to
select a supported cable. For HDD or other expansion unit options, see the specific expansion unit section.
rollers.
Internal SCSI Cabling
Netfinity 1000 systems have an IBM PCI Fast/Wide Ultra SCSI Adapter and support up to four internal SCSI devices through the 16-bit internal connector or 15
external SCSI devices through the 16-bit external 68-pin High Density connector; however, when internal SCSI devices are installed to the internal connector, only
one SCSI device can be supported from the external connector. All models are cabled internally with a four-drop, 16-bit wide SCSI cable with a built-in active
terminator at one end. The other end is attached to the internal 68-pin single-ended connector of the SCSI adapter. On the drive models, the hard disk drive (HDD)
is attached to the cable connector closest to the active terminator. On open bay models the first disk drive installed should be attached in the same manner. In the
event the standard four drop cable is attached to a RAID controller and a dedicated removable media attachment to the onboard controller is required, an optional,
terminated, 16-bit cable is available (Netfinity Two-Drop Internal SCSI Cable P/N 36L9636). If connecting narrow devices to this cable, additional 68-pin to 50-pin
converters (P/N 32G3925) must be ordered. Some narrow devices include a converter in their ship group.
Updated 01/01/00
For the latest product & technical information, refer to the Information Sources on pages 1 and 2.
11
Netfinity 1000 I/O Options
Part
Number
Description
Adapter
Length
PCI
Support
Slots
Supported
3
Full
32-bit
37L6086
Netfinity ServeRAID-3HB Ultra2 SCSI Adapter4
Full
32/64-bit
3
02K3454
PCI Fast/Wide Ultra SCSI Adapter
Half
32-bit
1, 2, 3
Networking5
Ethernet
34L1501
Netfinity 10/100 Ethernet PCI Adapter 2
Half
32-bit
1, 2, 3
08L3341
Netfinity 10/100 Fault Tolerant Adapter
Half
32-bit
1, 2, 3
Netfinity Gigabit Ethernet SX Adapter
Half
32/64-bit
1, 2, 3
34L0301
Token Ring
34L0501
Token-Ring 100/16/4 High-Speed PCI Adapter
Half
32-bit
1, 2, 3
34L0601
Token-Ring 16/4 PCI Adapter 2
Half
32-bit
1, 2, 3
33L4618
PCI V.90 56 Data/Fax Modem6
Half
32-bit
1, 2, 3
37L1414
Serial I/O SST8P DB Adapter7
Half
32-bit
1, 2, 3
37L1415
Serial I/O SST16P RJ Adapte7
Half
32-bit
1, 2, 3
37L1423
Serial I/O SST16P DB Adapter7
Half
32-bit
1, 2, 3
Full
ISA
4, 5, 6
-
-
-
Communications
Slot 1- PCI, 32-bit, Full Length
Slot 2- PCI, 32-bit, Full Length
Slot 3- PCI, 32-bit, Full Length
Slot 4- ISA, Full Length
Slot 5- ISA, Full Length
Slot 6- ISA, Full Length
AGP
Netfinity ServeRAID-3L Ultra2 SCSI Adapter2, 3
SCSI Adapter
Storage Controllers1
01K7364
Systems Management8
94G7578
PC Server Advanced Systems Management Adapter
94G5571
Advanced Systems Management Power Unit9
1. Netfinity1000 includes a single Wide Ultra SCSI PCI adapter.
2. All ServeRAID-3x adapters can be upgraded with the same enhanced software utilities and firmware included with ServeRAID-3HB. The download is available for no charge from
www.ibm.com/pc/support. Select “Server” in Brand pulldown, “ServeRAID” in Family pulldown and then “Downloadable files”. Installed firmware of less than V3.5 should consider the upgrade.
3. Netfinity ServeRAID-3L Ultra2 SCSI Adapter (P/N 01K7364) provides either one internal or one external LVDS SCSI channel.
4. Netfinity ServeRAID-3HB Ultra2 SCSI Adapter (P/N 37L6086) provides one internal and 2 external (0.8mm VHDCI) LVDS SCSI channels. The internal channel can be configured for external
usage (0.8mm VHDCI) providing a total of 3 external LVDS SCSI channels. Includes 32 MB of mirrored battery-backup cache which helps protect against data loss in write-back cache mode
in the event of a power outage or adapter maintenance.
5. Netfinity 1000 has an integrated 10/100 PCI Ethernet Controller.
6. Due to homologation variances, modem availability may differ by country.
7. See Appendix E for details on Serial I/O options and configuration limitations.
8. Netfinity 1000 provides the following integrated system management features - Vital Product Data (VPD) plus thermal, voltage, and fan sensors. For additional functions, optional PC Server
Advanced Systems Management (P/N 94G7578) may be utilized. To enable the adapter’s Automated Restart and Alerting as well as Remote Power On/Off features, Advanced Systems
Management Power Unit (P/N 94G5571) is required.
9. Provides continuous power to the PC Server Advanced Systems Management Adapter (P/N 94G7578) even when the system is powered off.
Netfinity 1000 Power, Monitor & Accessories
Part
Number
Description
Power1
Uninterruptible Power Supply (UPS)2
94G3134
APC Smart-UPS 700 (32 min. runtime at 160 Watts)
94G3135
APC Smart-UPS 1000 (51 min. runtime at 160 Watts)
65464AN
G54 Color Monitor 15” (13.7” Viewable Image Size), stealth black
Monitors
65474AN
G74 Color Monitor 17” (15.9” Viewable Image Size), stealth black
65494AN
G96 Color Monitor 19” (17.9” Viewable Image Size), stealth black
9513AG1
T55A Flat Panel Color Monitor (15.0” Viewable Image Size), stealth
black
1. Netfinity 1000 includes a 330 W voltage sensing power supply.
2. Stated runtimes and power are for typical configurations (approximately 70% of maximum
capacity). For additional information, see Appendix C: UPS Runtime Estimate.
12
Part
Number
Description
Bays
SCSI
Supported Interface
(bit)
Form
Factor
Termination 68/50-pin
Ext. Tape
Included
Converter Enclosures1
Incl.
01K1282
12/24GB DDS/3 4-mm Internal Tape Drive
2
8
3.5” HH or
5.25” HH
Y2
Y
3510020
00N7991
20/40 GB DDS/4 4-mm Internal Tape Drive
2
16 Ultra2 LVD
3.5”HH or
5.25” HH
Y2
N
3510020
2, 3
8
3.5” SL or
5.25” HH
Y2
Y
3510020
01K1319
10/20 GB NS Internal SCSI Tape Drive
32G3925
SCSI 68-pin to 50-pin Converter
-
8-16
Internal
N
Y
-
36L9636
Netfinity Two-Drop Internal SCSI Cable3
-
16
Internal
Y
N
-
-
8/16
Desktop
N
N
-
Associated Options
External Tape Enclosures
3510020
External Half High SCSI Storage Enclosure4
1. To determine cable requirements, note the tape drive’s SCSI interface, the appropriate SCSI controller from the system configurator section, and the desired enclosure, then refer to
Appendix D: Cables - Storage Units - Controllers.
2. Tape drive is capable of self termination.
3. Netfinity Two-Drop Internal SCSI Cable (P/N 36L9636) is a wide two-drop terminated cable and is required for attachment of internal tape drives to the onboard SCSI controller of a Netfinity
1000 when the internal hard disk drives are attached to a RAID controller.
4. Provides a black desktop 5.25” half-high (HH) tape enclosure. Connector is configurable as 50-pin Centronix or 68-pin high density. Requires either tape drive self termination or SCSI-2 16bit Active Terminator (P/N 32G3918).
NOTE: SCSI support is provided by system unit onboard (standard) controller (no RAID function) or PCI Fast Wide Ultra SCSI Adapter P/N 02K3454. Additional tape attributes can be found in
Appendix A: Tape Drive Attributes.
Sample Configurations
Note: The following sample configurations are for illustration only and may not be suitable for any specific customer installation. Contact your IBM Business Partner
or IBM Marketing Representative for assistance with your specific configuration requirements.
Workgroup Intranet Server
Part Number
Description
Quantity
8477-31Y
Netfinity 1000 (Pentium III 550/64 MB/0 GB)
1
01K1130
64 MB 100 MHz ECC SDRAM DIMM 1
1
20L0553
9.1 GB Wide Ultra2 SCSI HDD
3
01K1319
10/20 GB NS Internal SCSI Tape Drive
1
65464AN
G54 Color Monitor 15” (13.7” Viewable Image Size), stealth black
1
94G3135
APC Smart-UPS 1000
1
1. For a total of 128 MB of system memory.
An Internet server is a server that handles all requests from the Internet (Intranet or Extranet). Usually, this type of server has the same characteristics as a normal file
server. The main difference is that an Internet server talks a different language (TCP/IP vs. NETBEUI or IPX/SPX) and often needs to do an extra security check
(firewall). In the case of an Internet server, the server itself talks mostly to just one client, the Internet Service Provider (ISP), instead of many clients like a file server
does.
With this in mind, the IBM Netfinity 1000 was selected to provide an affordable price point for the growing Internet server market with Pentium III processing, 128 MB
of system memory (expandable to 768 MB), integrated 10/100 Ethernet controller, high-performance storage, and power protection with an APC Smart-UPS.
The configuration includes a tape backup unit for secure backup of critical data in the event of a system or storage failure.
File and Print Server
Part Number
Description
Quantity
8477-11Y
Netfinity 1000 (Pentium II 400/64 MB/0 GB)
1
01K1130
64 MB 100 MHz ECC SDRAM DIMM1
1
20L0553
9.1 GB Wide Ultra2 SCSI HDD
1
01K1319
10/20 GB NS Internal SCSI Tape Drive
1
65464AN
G54 Color Monitor 15” (13.7” Viewable Image Size), stealth black
1
94G3134
APC Smart-UPS 700
1
1. For a total of 128 MB of system memory.
A small business or departmental server is usually required to perform all typical server functions while servicing up to 50 users in a normal workgroup computing
environment, but doesn’t require the high-end performance and fault tolerance properties of larger servers.
The sample configuration above consists of an IBM Netfinity 1000 with 128 MB of memory and 9.1 GB of hard disk space. It has enough processor power and
memory to run most current network operating systems comfortably and enough hard disk drive space to store a significant amount of data with additional internal
storage expansion still available. Demanding network traffic is effectively handled by the standard 100 Mbps Ethernet connection.
This configuration also includes a tape backup unit, monitor, and a UPS to keep the system protected from power surges and outages.
Updated 01/01/00
For the latest product & technical information, refer to the Information Sources on pages 1 and 2.
13
IBM NETFINITY 1000
Netfinity 1000 Tape Options
IBM Netfinity 3000 Configurator
)
VD
r
)
)
,L
so
ns
D
)
s
)
I
ail ax)
a
d
ax D, F
a r r oce
RA
)
/Av d/M
l
d
,
M
/
M
a
n
a
)
t
St
td , HD
tP
IM
ta
ltr
Hz
(To e (
(S
s
s)
, S m en
RD
s(
,U
(M
ys Driv
al
ity Slot
bp
al
or )
d
R=
e
t
a
n
(
s
u
e
M
n
g
)
D
a
r,
tio
es (KB
t(
aB k
il) a il)
pe
na
r(
ax
d i D is
.
Qu owe
oc
ne
va
Op Ma
v
rS
le
r
ly
er
Pr che
d/M
P
l/A al/A
Me a r d
ol
E)
y(
r
so
t
(
p
r
h
f
m
a
c
o
D
s
t
t
be
e
p
S
t
a
o
t
p
e
(I
E
C
bl al H
an yste
on
To (Tot
y(
Su wa
ac
d
er
a
um
(
d
M
oc
r
C
C
r
F
v
r
b
r
n
:
N
n
S
o
S
O
a
o
P
m
SI
EC
ys lots
m
du dv.
rt
-R
we Hotm ter
rm
bo
Nu L2
SC
Ba
S
Pa
A
Me
Re
Fo
Po
Re In
CD
On
)
ax
d/M
t
S
8476-50U
5003
1/1
512
64/768 MB
Tower
1/1
-
-
-
10/100
U
4/2
72.8 GB 32X-14X1
6/4
6/5
8476-51U
5003
1/1
512
64/768 MB
Tower
1/1
-
-
-
10/100
U
4/2
9.1/72.8
GB2
32X-14X1
6/3
6/5
8476-60U
5503
4/2
72.8 GB
40X-17X1
6/4
6/5
1/1
512
64/768 MB
Tower
1/1
-
-
-
10/100
U
8476-61U
5503
1/1
512
64/768 MB
Tower
1/1
-
-
-
10/100
U
4/2
9.1/72.8
GB2
40X-17X1
6/3
6/5
8476-70U
6003
1/1
512
64/768 MB
Tower
1/1
-
-
-
10/100
U
4/2
72.8 GB 40X-17X1
6/4
6/5
8476-71U
6003
4/2
9.1/72.8
GB2
6/3
6/5
1/1
512
64/768 MB
Tower
1/1
-
-
-
10/100
U
40X-17X1
1. Variable read rate. Actual playback speed will vary and is often less than the maximum possible.
2. Standard Hard Disk Drives (HDD) are 7200 RPM. Maximum internal capacities assume replacement of standard hard disk drives with the largest supported IBM hard disk
drives.
3. Intel Pentium III processor.
Netfinity 3000 Processor Upgrades
Part
Number
Processor Upgrades with 512 KB Cache
Processor Speed
Upgrade1
10L5886
Netfinity 300 MHz Upgrade with Pentium II Processor
10L5883
Netfinity 350/100 MHz, 512KB Processor Upgrade with Pentium II Processor
10U, 11U
All 1xU
10L5884
Netfinity 400/100 MHz, 512KB Processor Upgrade with Pentium II Processor
All 1...2xU
10L5900
Netfinity 450/100 MHz, 512KB Processor Upgrade with Pentium II Processor
All 1...3xU
36L9673
Netfinity 500 MHz/512 KB Upgrade with Pentium III Processor
All 1...4xU
33L5112
Netfinity 550 MHz/512 KB Upgrade with Pentium III Processor
All 1...5xU
33L5106
Netfinity 600 MHz/512 KB Upgrade with Pentium III Processor
All 1...6xU
1.Requires removal of the standard processor. A maximum of one processor may be installed. Upgrades may require a BIOS update. To obtain the latest Flash BIOS,
access www.ibm.com/pc/support and enter machine type “Type-Model” in Quick Path. Select “Downloadable files” and then “BIOS”.
Netfinity 3000 Memory
DIMM Socket
DIMM Socket
DIMM Socket
Part Number
All Models Except
15U
64 MB
64 MB DIMM Standard
128 MB
1 x 01K1130
192 MB
1 x 01K1131
256 MB
1 x 01K1131, 1 x 01K1130
Memory Description
320 MB
2 x 01K1131
01K1133
32 MB 100 MHz ECC SDRAM DIMM
384 MB
3 x 01K11311
01K1130
64 MB 100 MHz ECC SDRAM DIMM
512 MB
2 x 01K11321
01K1131
128 MB 100 MHz ECC SDRAM DIMM
768 MB (max) 3 x 01K11321
01K1132
256 MB 100 MHz ECC SDRAM RDIMM1
This table does not represent all possible memory
configurations.
1. Replace standard DIMM.
1. 01K1132 is a registered DIMM and is not compatible with 01K1130,
01K1131, or 01K1133. Installation of this RDIMM requires replacement of the
standard DIMM.
14
Total
Memory
Netfinity 3000 Hard Disk Drive (HDD) Storage
Total Internal
Storage1
CD-ROM
HH
Standard
N/A
1 x 20L0553
Standard
2 x 20L0553 or 1 x 20L0554
1 x 20L0553
27.3 GB
3 x 20L0553
2 x 20L0553 or 1 x 20L0554
Bay 3
36.4 GB
4 x 20L0553 or 2 x 20L0554
3 x 20L0553
Diskette
45.5 GB
2 x 20L0554, 1 x 20L0553
2 x 20L0554
54.6 GB
3 x 20L0554
1 x 20L0553, 2 x 20L0554
Bay 5
63.7 GB
3 x 20L0554, 1 x 20L0553
3 x 20L0554
4 x 20L0554
4 x 20L05542
72.8 GB (max)
yes
This table does not represent all possible hard drive configurations.
1. Total Internal Storage listed is within + 0.2 GB unless otherwise noted.
2. Requires replacement of standard hard disk drive with largest optional supported hard disk
drive.
Usage
Part
Number
Description
RPM
Height
Bays
Max.
Supported Qty.
Internal Hard Disk Drives
(HDD)
IDE CD-ROM
2
5.25”1
HH
yes
open
20L0553
9.1 GB Wide Ultra2 SCSI HDD1
7200
SL
2,3,5,6
4
3
3.5”
SL
yes
open
20L0554
18.2 GB Wide Ultra2 SCSI HDD1
7200
SL
2,3,5,6
4
4
3.5”
SL
yes
diskette
5
3.5”
SL2
no
HDD on Drive
Models
6
3.5”
SL2
no
open
1. A 3.5” conversion kit is standard in Bay 2 for installation of 3.5” hard
disk drives.
2. Two slim-line bays can be combined to support a single half-high
device.
External Storage Expansion
Units2
Form Factor
35301RU
Netfinity EXP200 Storage Expansion Unit
Rack (3U)
37L5857
Netfinity EXP200 Rack-to-Tower
Conversion Kit
-
1. Performs as a Wide Ultra SCSI device when attached to the standard or an optional Wide Ultra SCSI adapter or
when sharing a cable with a non-Ultra2 device.
2. Not supported by the onboard external SCSI port. Select an optional SCSI controller then refer to see Appendix D:
Cables-Storage Units-Controllers to confirm the controller supports the desired External Storage Expansion Unit and
to select a supported cable. For HDD or other expansion unit options, see the specific expansion unit section.
Internal SCSI Cabling
Netfinity 3000 systems have an IBM PCI Fast/Wide Ultra SCSI Adapter and support up to four internal SCSI devices through the 16-bit internal connector or 15
external SCSI devices through the 16-bit external 68-pin High Density connector; however, when internal SCSI devices are installed to the internal connector, only
one SCSI device can be supported from the external connector. All models are cabled internally with a four-drop, 16-bit wide SCSI cable with a built-in active
terminator at one end. The other end is attached to the internal 68-pin single-ended connector of the SCSI adapter. On the drive models, the hard disk drive (HDD)
is attached to the cable connector closest to the active terminator. On open bay models the first disk drive installed should be attached in the same manner. In the
event the standard four drop cable is attached to a RAID controller and a dedicated removable media attachment to the onboard controller is required, an optional,
terminated, 16-bit cable is available (Netfinity Two-Drop Internal SCSI Cable P/N 36L9636). If connecting narrow devices to this cable, additional 68-pin to 50-pin
converters (P/N 32G3925) must be ordered. Some narrow devices include a converter in their ship group.
Updated 01/01/00
For the latest product & technical information, refer to the Information Sources on pages 1 and 2.
15
IBM NETFINITY 3000
5.25”
0 GB
9.1 GB
18.2 GB
Form Height Front
Factor
Access
1
Models x1U
(except 21U)
Bay 2
Bay 6
Bay
Models x0U
Netfinity 3000 I/O Options
Part
Number
Description
Adapter
Length
PCI
Support
Slots
Supported
3
32-bit
Full
32/64-bit
3
02K3454
PCI Fast/Wide Ultra SCSI Adapter
Half
32-bit
1, 2, 3
Networking5
Ethernet
34L1501
Netfinity 10/100 Ethernet PCI Adapter 2
Half
32-bit
1, 2, 3
08L3341
Netfinity 10/100 Fault Tolerant Adapter
Half
32-bit
1, 2, 3
Netfinity Gigabit Ethernet SX Adapter
Half
32/64-bit
1, 2, 3
34L0301
Token Ring
34L0501
Token-Ring 100/16/4 High-Speed PCI Adapter
Half
32-bit
1, 2, 3
34L0601
Token-Ring 16/4 PCI Adapter 2
Half
32-bit
1, 2, 3
33L4618
PCI V.90 56 Data/Fax Modem6
Half
32-bit
1, 2, 3
37L1414
Serial I/O SST8P DB Adapter7
Half
32-bit
1, 2, 3
37L1415
Serial I/O SST16P RJ Adapter7
Half
32-bit
1, 2, 3
37L1423
Serial I/O SST16P DB Adapter7
Half
32-bit
1, 2, 3
Full
ISA
4, 5, 6
-
-
-
Communications
AGP
Full
Netfinity ServeRAID-3HB Ultra2 SCSI Adapter4
Slot 4- ISA, Full Length
Slot 5- ISA, Full Length
Slot 6- ISA, Full Length
Netfinity ServeRAID-3L Ultra2 SCSI Adapter2, 3
37L6086
Slot 1- PCI, 32-bit, Full Length
Slot 2- PCI, 32-bit, Full Length
Slot 3- PCI, 32-bit, Full Length
01K7364
SCSI Adapter
Storage Controllers1
Systems Management8
94G7578
PC Server Advanced Systems Management Adapter
94G5571
Advanced Systems Management Power Unit9
1. Netfinity 3000 includes a single Wide Ultra SCSI PCI adapter.
2. All ServeRAID-3x adapters can be upgraded with the same enhanced software utilities and firmware included with ServeRAID-3HB. The download is available for no charge from
www.ibm.com/pc/support. Select “Server” in Brand pulldown, “ServeRAID” in Family pulldown and then “Downloadable files”. The upgrade should be considered for installations with
firmware less than Version 3.5.
3. Netfinity ServeRAID-3L Ultra2 SCSI Adapter (P/N 01K7364) provides either one internal or one external LVDS SCSI channel.
4. Netfinity ServeRAID-3HB Ultra2 SCSI Adapter (P/N 37L6086) provides one internal and 2 external (0.8mm VHDCI) LVDS SCSI channels. The internal channel can be configured for external
usage (0.8mm VHDCI) providing a total of 3 external LVDS SCSI channels. Includes 32 MB of mirrored battery-backup cache which helps protect against data loss in write-back cache mode
in the event of a power outage or adapter maintenance.
5. Netfinity 3000 has an integrated 10/100 PCI Ethernet Controller.
6. Due to homologation variances, modem availability may differ by country.
7. See Appendix E for details on Serial I/O options and configuration limitations.
8. Netfinity 3000 provides the following integrated system management features - Vital Product Data (VPD) plus thermal, voltage and fan sensors. For additional functions, optional PC Server
Advanced Systems Management Adapter (P/N 94G7578) may be utilized. To enable the adapter’s Automated Restart and Alerting as well as Remote Power On/Off features, Advanced
Systems Management Power Unit (P/N 94G5571) is required.
9. Provides continuous power to the PC Server Advanced Systems Management Adapter (P/N 94G7578) even when the system is powered off.
Netfinity 3000 Power, Monitor & Accessories
Part Number
Description
Power1
Uninterruptable Power Supply (UPS)2
94G3134
APC Smart-UPS 700 (32 min. runtime at 160 Watts)
94G3135
APC Smart-UPS 1000 (51 min. runtime at 160 Watts)
65464AN
G54 Color Monitor 15” (13.7” Viewable Image Size), stealth black
Monitors
65474AN
G74 Color Monitor 17” (15.9” Viewable Image Size), stealth black
65494AN
G96 Color Monitor 19” (17.9” Viewable Image Size), stealth black
9513AG1
T55A Flat Panel Color Monitor (15.0” Viewable Image Size), stealth
black
1. Netfinity 3000 includes a 330 W voltage sensing power supply.
2. Stated runtimes and power are for typical configurations (approximately 70% of maximum capacity).
For additional information, see Appendix C: UPS Runtime Estimate.
16
Netfinity 3000 Tape Options
Part
Number
Description
Bays
SCSI
Supported Interface
(bit)
Form
Factor
Termination 68/50-pin
Ext. Tape
Included
Converter Enclosures1
Incl.
01K1282
12/24GB DDS/3 4-mm Internal Tape Drive
2
8
3.5” HH or
5.25” HH
Y2
Y
3510020
00N7991
20/40 GB DDS/4 4-mm Internal Tape Drive
2
16 Ultra2 LVD
3.5” HH or
5.25” HH
Y2
N
3510020
2, 3
8
3.5” SL or
5.25” HH
Y2
Y
3510020
01K1319
10/20 GB NS Internal SCSI Tape Drive
32G3925
SCSI 68-pin to 50-pin Converter
-
8-16
Internal
N
Y
-
36L9636
Netfinity Two-Drop Internal SCSI Cable3
-
16
Internal
Y
N
-
-
8/16
Desktop
N
N
-
Associated Options
External Half High SCSI Storage Enclosure4
1. To determine cable requirements, note the tape drive’s SCSI interface, the appropriate SCSI controller from the system configurator section, and the desired enclosure, then refer to
Appendix D: Cables - Storage Units - Controllers.
2. Tape drive is capable of self termination.
3. Netfinity Two-Drop Internal SCSI Cable (P/N 36L9636) is a wide two-drop terminated cable and is required for attachment of internal tape drives to the onboard SCSI controller of a
Netfinity 3000 when the internal hard disk drives are attached to a RAID controller.
4. Provides a black desktop 5.25” half-high (HH) tape enclosure. Connector is configurable as 50-pin Centronix or 68-pin high density. Requires either tape drive self termination or SCSI-2
16-bit Active Terminator (P/N 32G3918).
NOTE: SCSI support is provided by system unit onboard (standard) controller (no RAID function) or PCI Fast Wide Ultra SCSI Adapter P/N 02K3454. Additional tape attributes can be found
in Appendix A: Tape Drive Attributes.
Sample Configurations
Note: The following sample configurations are for illustration only and may not be suitable for any specific customer installation. Contact your IBM Business Partner
or IBM Marketing Representative for assistance with your specific configuration requirements.
Workgroup Intranet Server
Part Number
Description
Quantity
8476-71U
Netfinity 3000 (Pentium III 600/64 MB/9.1 GB)
1
01K1130
64 MB 100 MHz ECC SDRAM DIMM 1
1
20L0553
9.1 GB Wide Ultra2 SCSI HDD
2
01K1319
10/20 GB NS Internal SCSI Tape Drive
1
65464AN
G54 Color Monitor 15” (13.7” Viewable Image Size), stealth black
1
94G3135
APC Smart-UPS 1000
1
1. For a total of 128 MB of system memory.
An Internet server is a server that handles all requests from the Internet (Intranet or Extranet). Usually, this type of server has the same characteristics as a normal file
server. The main difference is that an Internet server talks a different language (TCP/IP vs. NETBEUI or IPX/SPX) and often needs to do an extra security check
(Firewall). In the case of an Internet server, the server itself talks mostly to just one client, the Internet Service Provider (ISP), instead of many clients like a file server
does.
With this in mind, the IBM Netfinity 3000 was selected to provide an affordable price point for the growing Internet server market with Pentium III processing, 128 MB
of system memory (expandable to 768 MB), integrated 10/100 Ethernet controller, and high-performance storage, and power protection with an APC Smart-UPS.
The configuration includes a tape backup unit for secure backup of critical data in the event of a system or storage failure.
File and Print Server
Part
Number
8476-50U
Description
Quantity
Netfinity 3000 (Pentium III 500/64 MB/0 GB)
1
01K1130
64 MB 100 MHz ECC SDRAM DIMM1
1
20L0553
9.1 GB Wide Ultra2 SCSI HDD
1
01K1319
10/20 GB NS Internal SCSI Tape Drive
1
65464AN
G54 Color Monitor 15” (13.7” Viewable Image Size), stealth black
1
94G3134
APC Smart-UPS 700
1
1. For a total of 128 MB of system memory.
A small business or departmental server is usually required to perform all typical server functions while servicing up to 50 users in a normal workgroup computing
environment, but doesn’t require the high-end performance and fault tolerance properties of larger servers. The sample configuration above consists of an IBM
Netfinity 3000 with 128 MB of memory and 9.1 GB of hard disk space. It has enough processor power and memory to run most current network operating systems
comfortably and enough hard disk drive space to store a significant amount of data with additional internal storage expansion still available. Demanding network
traffic is effectively handled by the standard 100 Mbps Ethernet connection. This configuration also includes a tape backup unit, monitor, and a UPS to keep the
system protected from power surges and outages.
Updated 01/01/00
For the latest product & technical information, refer to the Information Sources on pages 1 and 2.
17
IBM NETFINITY 3000
External Tape Enclosures
3510020
IBM Netfinity 3500 M10 Configurator
)
.)
VD
, L vail ax)
s
s) )
s
D
n
)
I
A
a a r d ce
x
/
A
)
l
F
a
d/ M
a
d
ro
,R
D,
/M
St
ot
MM
td HD tan nt P
tra s (T ve (
DI
)
l
S
S
s
R
(
,
(
)
U
e
p
y
=
ri
y ots al,
l,
rs
Hz
(R
Ba k D
em
l
Mb
tit
n
ua
so
.)
(M
B)
x.)
an r, S ptio nag et (
(D edia D is
d
es . ( K
l.) vail
a
u
e
n
r
e
c
a
Q
r
M
ai
O
d
ro
lle le M
pe
r
E)
he td./
ly (Pow cy ( m M the
Av tal/A
ar
P
o
/
r
S
c
p
D
l
r
H
f
I
o
be
r
(
ta To
p
nt
ab
up
Ca y (S
ct
m
an ste rd E
al
ro
so
ov
Co
Fa
a
(To ts (
rn
OM
r S wa nd Sy
Nu
es
be ECC mor
-R
s:
m
bo
SI Rem Inte
rt
lo
we ot-S edu dv.
oc
rm
y
e
n
D
u
r
C
a
2
S
o
o
a
C
P
N
M
L
A
P
O
S
R
H
F
P
B
)
ax
d/M
t
S
8655-11Y
5002
8655-12Y
500
2
1/2
512
128 MB/1 GB
Tower
1/1
-
-
-
10/100
U
4/2
8655-21Y
5502
1/2
512
128 MB/1 GB
Tower
1/1
-
-
-
10/100
U
8655-22Y
5502
1/2
512
128 MB/1 GB
Tower
1/1
-
-
-
10/100
8655-31Y
6002
1/2
512
128 MB/1 GB
Tower
1/1
-
-
-
10/100
8655-32Y
6002
1/2
1/2
512
512
64 MB/1 GB
128 MB/1 GB
Tower
Tower
1/1
1/1
-
-
-
-
-
-
10/100
10/100
40X-17X1
6/4
6/5
9.1/72.8 GB
40X-17X1
6/3
6/5
4/2
72.8 GB
40X-17X1
6/4
6/5
U
4/2
9.1/72.8 GB3
40X-17X1
6/3
6/5
U
4/2
72.8 GB
40X-17X1
6/4
6/5
40X-17X1
6/3
6/5
U
U
4/2
4/2
72.8 GB
3
9.1/72.8
GB3
1. Variable read rate. Actual playback speed will vary and is often less than the maximum possible.
2. Intel Pentium III processor.
3. Standard Hard Disk Drives (HDDs) are 7200 RPM. Maximum internal capacities assume replacement of standard hard disk drives with the largest supported IBM hard disk drives.
Netfinity 3500 M10 Processor Upgrades
Part Number
Processor Upgrades with 512 KB Cache
SMP
Support1
Processor Speed
Upgrade2
36L9673
Netfinity 500 MHz/512 KB Upgrade with Pentium III Processor
All 1xY
-
33L5112
Netfinity 550 MHz/512 KB Upgrade with Pentium III Processor
All 2xY
All 1xY
33L5106
Netfinity 600 MHz/512 KB Upgrade with Pentium III Processor
All 3xY
All 1...2xY
1. One additional processor may be installed, providing a maximum of two. All processors must be identical in type, speed, and cache size.
2. Requires removal of the standard processor. A maximum of two processors may be installed. All processors must be identical in type, speed and cache size.
Upgrades may require a BIOS update. To obtain the latest Flash BIOS, access www.ibm.com/pc/support and enter machine type “Type-Model” in Quick Path.
Select “Downloadable files” and then “BIOS”.
Netfinity 3500 M10 Memory
Part Number
Memory Description
01K1130
64 MB 100 MHz ECC SDRAM DIMM
01K1131
128 MB 100 MHz ECC SDRAM DIMM
01K1132
256 MB 100 MHz ECC SDRAM Registered DIMM1
1. P/N 01K1132 is a registered DIMM and is not compatible with 01K1130 or 01K1131. Installation of this RDIMM
requires replacement of the standard DIMM.
Std. DIMM
(R)DIMM Socket 0
(R)DIMM Socket 1
(R)DIMM Socket 2
(R)DIMM Socket 3
18
Total Memory
Model 11Y
All Models Except 11Y
64 MB
64 MB DIMM standard
128 MB
1 x 01K1130
128 MB DIMM standard
-
192 MB
1 x 01K1131
1 x 01K1130
256 MB
1 x 01K1131, 1 x 01K1130
1 x 01K1131 or 1 x 01K11321
320 MB
2 x 01K1131
1 x 01K1131, 1 x 01K1130
384 MB
2 x 01K1131, 1 x 01K1130
2 x 01K1131
448 MB
3 x 01K1131
2 x 01K1131, 1 x 01K1130
512 MB
4 x 01K1131 or 2 x 01K11322
3 x 01K1131 or 2 x 01K11321
768 MB
3 x 01K11321
3 x 01K11321
1024 MB (max)
4 x 01K11322
4 x 01K11322
This table does not represent all possible memory configurations.
1. P/N 01K1132 is a registered DIMM and is not compatible with 01K1130 or 01K1131. Installation of this RDIMM requires replacement of the
standard DIMM.
2. Replace standard DIMM.
Netfinity 3500 M10 Hard Disk Drive (HDD) Storage
Open Bay Examples2
9.1 GB
Bay 2
9.1 GB
Bay 3
18.2 GB
2 x 20L0553 or
1 x 20L0553
10,000 RPM Hard Disk Drives
(HDDs)
18.2 GB
1 x 20L0554
-
9.1 GB
18.2 GB
1 x 00N8071
-
2 x 00N8071 or
1 x 00N8072
Diskette
27.3 GB
3 x 20L0553
36.4 GB
4 x 20L0553 or
Bay 5
54.6 GB
-
3 x 20L0554
-
3 x 00N8072
72.8 GB (max)
-
4 x 20L0554
-
4 x 00N8072
Bay 6
Bay
7,200 RPM Hard Disk
Drives (HDDs)
2 x 20L0554
3 x00N8071
-
4 x 00N8071 or
2 x 00N8072
This table does not represent all possible hard drive configurations.
1. Total Internal Storage listed is within + 0.2GB unless otherwise noted.
2. When configuring disk drive models (8655-x2Y) which include a single 9.1 GB 7,200 RPM HDD, use the 9.1 GB 7200 RPM
column and order one less 20L0553 than the table indicates.
Form Height Front
Factor
Access
Usage
Part
Number
Description
RPM Height
Bays
Max
Supported Qty.
Internal Hard Disk Drives (HDD)
1
5.25”
HH
yes
IDE CD-ROM
2
5.25”1
HH
yes
open
20L0553
9.1 GB Wide Ultra2 SCSI HDD1
7200
SL
2,3,5,6
3
3.5”
SL
yes
open
20L0554
18.2 GB Wide Ultra2 SCSI HDD1
7200
SL
2,3,5,6
4
4
3.5”
SL
yes
diskette
00N8071
9.1 GB 10,000 rpm Wide Ultra2 SCSI HDD1
10000
SL
2,3,5,6
4
5
3.5”
SL2
no
HDD on drive
models
00N8072
18.2 GB 10,000 rpm Ultra2 SCSI HDD1
10000
SL
2,3,5,6
4
3.5”
SL2
6
no
2
External Storage Expansion Units
open
1. A 3.5” conversion kit is standard in Bay 2 for installation of 3.5”
hard disk drives.
2. Two slim-line (SL) bays can be combined to support a single
half-high (HH) device.
35301RU
Netfinity EXP200 Storage Expansion Unit
37L5857
Netfinity EXP200 Rack-to-Tower Conversion Kit
4
Form Factor
Rack (3U)
-
1. Performs as a Wide Ultra SCSI device when attached to the standard or an optional Wide Ultra SCSI adapter or when
sharing a cable with a non-Ultra2 device.
2. Not supported by the onboard external SCSI port. Select an optional SCSI controller then refer to see Appendix D:
Cables-Storage Units-Controllers to confirm the controller supports the desired External Storage Expansion Unit and to
select a supported cable. For HDD or other expansion unit options, see the specific expansion unit section.
Netfinity 3500 M10 Internal SCSI Cabling
Netfinity 3500 M10 systems are cabled internally with a four-drop, 16-bit wide SCSI cable with a built-in active terminator at one end of the cable. The other end of
the cable is attached to the internal 68-pin single-ended connector of the dual channel Ultra SCSI controller. On drive models the hard disk drive is attached to the
cable connector closest to the active terminator. On open bay models the first disk drive installed should be attached in the same manner to ensure the highest
signal quality. In the event the standard four-drop cable is attached to a RAID controller and a dedicated removable media attachment to the onboard controller is
required, an optional, terminated, 16-bit cable is available (Netfinity Two-Drop Internal SCSI Cable P/N 36L9636). If connecting narrow devices to this cable,
additional 68-pin to 50-pin converters (P/N 32G3925) must be ordered. Some narrow devices include a converter in their ship group. The second Ultra SCSI
channel is available for external device support through an external 68-pin high density connector.
Updated 01/01/00
For the latest product & technical information, refer to the Information Sources on pages 1 and 2.
19
IBM NETFINITY 3500 M10
CD-ROM
Total Internal
Storage1
Netfinity 3500 M10 I/O Options
Part
Number
Description
Adapter
Length
PCI
Support
Slots
Supported
Full
32-bit
3...65, 6
Storage Controllers1
01K7364
Netfinity ServeRAID-3L Ultra2 SCSI Adapter2, 3
37L6086
Netfinity ServeRAID-3HB Ultra2 SCSI Adapter4
Full
32/64-bit
3...65, 6
02K3454
PCI Fast/Wide Ultra SCSI Adapter
Half
32-bit
2...6
Networking
7
Slot 1 - AGP Video Adapter (8 MB)
Slot 2 - PCI, 32-bit, Full Length
Slot 3 - PCI, 32-bit, Full Length
Ethernet
Slot 4 - PCI, 32-bit, Full Length
34L1501
Netfinity 10/100 Ethernet PCI Adapter 2
Half
32-bit
2...6
08L3341
Netfinity 10/100 Fault Tolerant Adapter
Half
32-bit
2...6
34L0301
Netfinity Gigabit Ethernet SX Adapter
Half
32/64-bit
3...66
Token Ring
Slot 5 - PCI, 32-bit, Full Length
Slot 6 - PCI/ISA, Full Length1
1. Due to the lack of a slot 6 card
34L0501
Token-Ring 100/16/4 High-Speed PCI Adapter
Half
32-bit
2...6
guide, Netfinity 3500 M10 must NOT
34L0601
Token-Ring 16/4 PCI Adapter 2
Half
32-bit
2...6
be transported with a full length
Communications8
adapter occupying slot 6. Damage
33L4618
PCI V.90 56 Data/Fax
Modem9
Half
32-bit
2...6
37L1414
Serial I/O SST8P DB Adapter10
Half
32-bit
2...610
32-bit
2...610
37L1415
Serial I/O SST16P RJ
Adapter10
Half
37L1423
Serial I/O SST16P DB Adapter10
Half
32-bit
2...610
37L1416
Serial I/O SST128P Expandable Adapter10
Half
32-bit
2...610
due to adapter flexure during
transportation could occur.
Systems Management11
1. Netfinity 3500 M10 has two integrated Wide Ultra SCSI channels. One is internal and the other is external with a 68-pin high density connector.
2. All ServeRAID-3x adapters can be upgraded with the same enhanced software utilities and firmware included with ServeRAID-3HB. The download is available for no charge from
www.ibm.com/pc/support. Select “Server” in the Brand pulldown, “ServeRAID” in the Family pulldown and then “Downloadable files”. The upgrade should be considered for installations with
firmware less than Version 3.5.
3. Netfinity ServeRAID-3L Ultra2 SCSI Adapter (P/N 01K7364) provides either one internal or one external (0.8-mm VHDCI) LVDS SCSI channel.
4. Netfinity ServeRAID-3HB Ultra2 SCSI Adapter (P/N 37L6086) provides one internal and two external (0.8-mm VHDCI) LVDS SCSI ch annels. The internal channel can be configured for
external usage (0.8-mm VHDCI connector) providing a total of three external LVDS SCSI channels. Includes 32 MB of mirrored batt ery backup cache, which helps protect against data loss
in write-back cache mode in the event of a power outage or adapter maintenance.
5. Due to the lack of a slot 6 card guide, Netfinity 3500 M10 must NOT be transported with a full length adapter occupying slot 6. Damage due to adapter flexure during transportation could
occur.
6. Slot 2 will not support installation of a RAID or 64-bit PCI adapter.
7. Netfinity 3500 M10 has an integrated 10/100 PCI Ethernet Controller.
8.Netfinity 3500 M10 includes two USB ports, two high-speed, NS16550A software-compatible serial ports, and one high-speed parallel port supporting devices using SSP/EPP/ECP
protocols adhering to the IEEE 1284 standard.
9. Due to homologation variances, modem availability may differ by country.
10. See Appendix E for details on Serial I/O options and configuration limitations. A maximum of four Serial I/O adapters (any combination of P/N 37L1414, 37L1415, 37L1416, and 37L1423)
may be installed.
11. Netfinity 3500 M10 integrated system management features include Vital Product Data (VPD) and alerts generated through Netfinity Manager from thermal, voltage and fan sensors.
Netfinity 3500 M10 Power, Monitor & Accessories
Part Number
Description
Power1
Uninterrupted Power Supply (UPS)2
94G3134
APC Smart-UPS 700 (20 min. runtime at 210 Watts)
94G3135
APC Smart-UPS 1000 (36 min. runtime at 210 Watts)
65464AN
G54 Color Monitor 15” (13.7” Viewable Image Size), stealth black
Monitors
65474AN
G74 Color Monitor 17” (15.9” Viewable Image Size), stealth black
65494AN
G96 Color Monitor 19” (17.9” Viewable Image Size), stealth black
9513AG1
T55A Flat Panel Color Monitor (15.0” Viewable Image Size), stealth black
1. Netfinity 3500 includes a 330 W voltage sensing power supply.
2. Stated runtimes and power are for typical configurations (approximately 70% of maximum capacity). For
additional information, see Appendix C: UPS Runtime Estimate.
20
Netfinity 3500 M10 Tape Options
Part
Number
Description
01K1319
10/20 GB NS Internal SCSI Tape Drive
01K1325
20/40 GB 8-mm Internal SCSI Tape Drive
00N7990
40/80 GB DLT Internal SCSI Tape Drive
32G3918
SCSI-2 16-bit Active Terminator
32G3925
SCSI 68-pin to 50-pin Converter
36L9636
Netfinity Two-Drop Internal SCSI Cable6
Bays
SCSI
Form Termination
Supported Interface Factor
Included
(bit)
68/50-pin
Converter
Incl.
Ext. Tape
Enclosures1
2,3
8
3.5” SL or
5.25” HH
Y2
Y
3510020,
3551001
2
16
5.25”HH
N3
N
3510020,4
3551001
N/A5
16 LVD
5.25”FH
N
N
3503BOX,4
3551001
-
16
External
Y
N
3510020
-
8-16
Internal
N
Y
3551001
-
16
Internal
Y
N
-
Associated Options
External Tape Enclosures
3510020
External Half High SCSI Storage Enclosure7
-
8/16
Desktop
N
N
-
3551001
NetMEDIA Storage Expansion Unit EL8
-
16
Rack
Y
N
-
NetMEDIA Systems Management Adapter9
-
16
-
N
N
3551001
DLT External SCSI Enclosure10
-
16
Desktop
N
N
-
10L7113
3503BOX
1. To determine cable requirements, note the tape drive’s SCSI interface, the appropriate SCSI controller from the system configurator section, and the desired enclosure, then refer to
Appendix D: Cables-Storage Units-Controllers.
2. Tape drive is capable of self termination.
3. Termination is provided by the system unit’s standard 4-drop SCSI cabling.
4. Requires SCSI-2 16-bit Active Terminator (P/N 32G3918).
5. Netfinity 3500 M10 does not support full high devices internally. See External Tape Enclosure column.
6. Netfinity Two-Drop Internal SCSI Cable (P/N 36L9636) is a wide two-drop terminated cable and is required for attachment of internal tape drives to the onboard SCSI controller of a
Netfinity 3500 M10 when the hard disk drives are attached to a RAID Controller.
7. Provides a black desktop 5.25” half-high (HH) tape enclosure. Connector is configurable as 50-pin Centronix or 68-pin high density. Requires either tape drive self termination or SCSI-2
16-bit Active Terminator (P/N 32G3918).
8. Provides a black 3U, 19” rack or NetBAY3 mountable tape enclosure. Provides two full high (FH) or four half high (HH) extended length 5.25” bays. External connector is 0.8-mm VHDCI.
Includes two power supplies and two power cords.
9. Installs in a 3551001. Provides repeater function and LVDS interface allowing longer cable lengths and auto-termination when the 3551001 is powered off.
10. Provides a black desktop DLT tape enclosure with a 68-pin high density external connector. Requires termination by the tape drive or by installation of a SCSI-2 16-bit Active Terminator
(P/N 32G3918).
Sample Configurations
Note: The following sample configurations are for illustration only and may not be suitable for any specific customer installation. Contact your IBM Business Partner
or IBM Marketing Representative for assistance with your specific configuration requirements.
Internet Server
Part Number
8655-22Y
Description
Quantity
Netfinity 3500 M10 (Pentium III 550/128 MB/9.1 GB)
1
128 MB 100 MHz ECC SDRAM DIMM1
1
20L0553
9.1 GB Wide Ultra2 SCSI HDD2
2
01K1319
10/20 GB NS Internal SCSI Tape Drive
1
01K1131
65464AN
G54 Color Monitor 15” (13.7” Viewable Image Size), stealth black
1
94G3134
APC Smart-UPS 700
1
1. For a total of 256 MB of system memory.
2. For a total of 27.3 GB of internal storage.
An Internet server is a server that handles all requests from the Internet (Intranet or Extranet). Usually, this type of server has the same characteristics as a normal file
server. The main difference is that an Internet server talks a different language (TCP/IP vs. NETBEUI or IPX/SPX) and often needs to do an extra security check
(Firewall). In the case of an Internet server, the server itself talks mostly to just one client, the Internet Service Provider (ISP), instead of many clients like a file server
does.
With this in mind, the IBM Netfinity 3500 M10 was selected to provide an affordable price point for the growing Internet server market with two-way Pentium III
processing, 256 MB of system memory (expandable to 1 GB), and power protection with an APC Smart-UPS.
The network configuration depends on the method that will be used to connect the server to the Internet. Usually fast Ethernet routers are used, but if other methods
are used, you can add the appropriate adapter. The configuration includes a tape backup unit for secure backup of critical data in the event of a system or storage
failure.
Updated 01/01/00
For the latest product & technical information, refer to the Information Sources on pages 1 and 2.
21
IBM NETFINITY 3500 M10
NOTE: SCSI support for tape drives is provided by system unit onboard (standard) controller (no-RAID function) or PCI Fast Wide Ultra SCSI Adapter P/N 02K3454. Additional tape
attributes can be found in Appendix A: Tape Drive Attributes.
File and Print Server
Part Number
Description
Quantity
8655-11Y
Netfinity 3500 M10 (Pentium III 500/64 MB/0 GB)
1
01K1131
128 MB 100 MHz ECC SDRAM DIMM1
1
20L0554
18.2 GB Wide Ultra2 SCSI HDD2
3
01K1325
20/40 GB 8-mm Internal SCSI Tape Drive
1
65464AN
G54 Color Monitor 15” (13.7” Viewable Image Size) stealth black
1
94G3134
APC Smart-UPS 700
1
1. For a total of 192 MB of system memory.
2. For a total of 54.6 GB of internal storage.
A small business or departmental server is usually required to perform all typical server functions while servicing up to 100 users in a normal workgroup computing
environment, but doesn’t require the high-end performance and fault tolerance properties of larger servers.
The sample configuration above consists of an IBM Netfinity 3500 M10 with 192 MB of memory and 54.6 GB of hard disk space. It has enough processor power and
memory to run most current network operating systems comfortably and enough hard disk drive space to store a significant amount of data with additional external
storage expansion still available. Demanding network traffic is effectively handled by the standard 100 Mbps Ethernet connection.
This configuration also includes a tape backup unit, monitor, and a UPS to keep the system protected during power surges and outages
Application Server
Part Number
Description
Quantity
8655-32Y
Netfinity 3500 M10 (Pentium III 600/128 MB/9.1 GB)
1
33L5106
Netfinity 600 MHz/512 KB Upgrade with Pentium III Processor
1
01K1132
256 MB 100 MHz ECC SDRAM Registered DIMM1
1
01K7364
Netfinity ServeRAID-3L Ultra2 SCSI Adapter
1
36L9636
Netfinity Two-Drop Internal SCSI Cable
1
20L0553
9.1 GB Wide Ultra2 SCSI HDD2
2
01K1319
10/20 GB NS Internal SCSI Tape Drive
1
65464AN
G54 Color Monitor 15” (13.7” Viewable Image Size), stealth black
1
94G3134
APC Smart-UPS 700
1
1. For a total of 256 MB of registered system memory. Requires removal of standard memory.
2. For a total of 27.3 GB of internal storage .
An application server differs from a file server and print server in that it has a higher workload, in providing application serving requirements for users. With this in
mind, the IBM Netfinity 3500 M10 was selected to provide an affordable price point for an application server, with two-way Pentium III processing, 256 MB of system
memory (expandable to 1 GB), and availibilty features such as RAID protected internal storage and power protection with an APC Smart-UPS.
22
IBM NETFINITY 3500 M10
Updated 01/01/00
For the latest product & technical information, refer to the Information Sources on pages 1 and 2.
23
IBM Netfinity 4000R Configurator
)
VD
r
1
l)
,L
s)
so
)
)
)
D
ai
s
n
d
ax
AI
ax , Fa
ce
1
/Av
a
ar
R
M
l
o
/
M
d
)
r
/
M
,
a
D
/
n
t
a
td
M
td HD
td
tP
ta
)
(S
ltr
(To
IM
(S
)
,
(S
en bps
,S
ys
Hz
RD
l, U
ive
m
ity lots
rs )
al
r
a
t
a
=
e
m
o
n
1
(
(M
n
1
B
D
a
ag
ss KB
Du
)R
,S
)
d
tio
a
)
et
isk
r(
di
an
ce e . (
ax
Qu wer
a il
ee
a il
rn
Op
e
e
o
D
)
v
(
p
v
l
M
y
M
e
r
r
l
/
l
o
h
E
A
M
h
p
l/
rd
l/A
ro
rS
or
cy
(P
f P Cac (Std
be
em d E t
(ID
ta
ta
up
nt
ct
p
ble
m
Ha
so
an
st
ro
Fa
(To
va
r S Swa
Co
es
(To
al
ry
ar
nd
OM
Nu
Sy
be EC C
o
:
e
:
c
I
n
o
o
u
R
t
.
m
s
r
s
o
b
S
m 2
r
m
d
w ot
r
v
m
y
ot
te
Pr
Pa
L
Fo
CD
Po
Ad
SC
Re
Re
H
On
Nu
In
Ba
Sl
Me
1
x)
865211Y2, 3
5004
1/2
512
256MB/2GB Rack(1U)
1/1
-
-
-
2 x10/100
U
1/0
9.1/
36.4GB5
24X-10X6
3/1
2/1
865221Y2, 3
5004
2/2
512
512MB/2GB
Rack(1U)
1/1
-
-
-
2 x10/100
U
1/0
18.2/
36.4GB5
24X-10X6
3/0
2/1
865222Y2, 3
5004
2/2
512
1GB/2GB
Rack(1U)
1/1
-
-
-
2 x10/100
U
1/0
18.2/
36.4GB5
24X-10X6
3/0
2/1
1. The Netfinity 4000R does not support customer installation of adapters, HDDs, memory, processors, or any other devices that must be installed inside the server. Non-standard
features must be installed at the factory. Contact your IBM Marketing Representative for more information.
2. Available in the US only.
3. Requires Console Cable Set P/N 94G7447 and an available console switch port. Housed in a 19” rack mountable drawer and ships standard without a keyboard or mouse. See
“Rack and NetBay” under “Netfinity 4000R Power, Monitor & Accessories” for supported IBM racks.
4. Intel Pentium III processor
5. Standard Hard Disk drives (HDD) are 7200 RPM. Maximum internal capacities assume factory replacement of standard hard disk drives with the largest supported IBM hard disk
drives.
6. Variable read rate. Actual playback speed will vary and is often less than the maximum possible.
Netfinity 4000R Processor Upgrades
Part Number
N/A1
Processor Upgrades with 512KB Cache
SMP Support
All 1xY2
Netfinity 500 MHz/512 KB Upgrade with Pentium III Processor
1.The Netfinity 4000R does not support customer installation of adapters, HDDs, memory, processors, or any other devices that must be installed inside the server. Non-standard features
must be installed at the factory. Contact your IBM Marketing Representative for more information.
2. One additional processor may be installed, providing a maximum of two. All processors must be identical in type, speed and cache size.
Netfinity 4000R Memory
RDIMM Socket
RDIMM Socket
RDIMM Socket
RDIMM Socket
Part Number
Memory Description
N/A1
128MB 100MHz ECC SDRAM RDIMM
N/A1
256MB 100MHz ECC SDRAM RDIMM
N/A1
512MB 100MHz ECC SDRAM RDIMM
1. The Netfinity 4000R does not support customer installation of adapters, HDDs, memory,
processors, or any other devices that must be installed inside the server. Non-standard features
must be installed at the factory. Contact your IBM Marketing Representative for more information.
24
Netfinity 4000R Hard Disk Drive (HDD) Storage
Bay
Form
Factor
Height
Front
Access
Usage
1
5.25”
SL
yes
IDE CDROM
21
3.5”
SL
no
open/HDD
N/A1
9.1GB 7200 RPM SCSI HDD
7200
SL
31
3.5”
SL
no
Std HDD
N/A1
18.2GB 7200 RPM SCSI HDD
7200
SL
1. The Netfinity 4000R does not support customer installation of
adapters, HDDs, memory, processors, or any other devices that
must be installed inside the server. Non-standard features must
be installed at the factory. Contact your IBM Marketing
Representative for more information.
Part
Number
Description
RPM Height
Internal Hard Disk Drives (HDD)
1. A maximum of two SL HDDs may be installed. The Netfinity 4000R does not support
customer installation of adapters, HDDs, memory, processors, or any other devices that must
be installed inside the server. Non-standard features must be installed at the factory. Contact
your IBM Marketing Representative for more information.
Internal SCSI Cabling
Netfinity 4000R servers contain a single channel Wide Ultra SCSI adapter that has two 68-pin connectors to support SCSI device attachment. One connector
supports 16-bit internal SCSI devices, while the other supports a 16-bit external device. Up to two Wide Ultra SCSI HDDs can be supported internally. External
support is limited to one SCSI device. Non-standard features must be installed at the factory. Contact your IBM Marketing Representative for more information.
Netfinity 4000R I/O Options
Part
Number
Description
Storage Controllers2
N/A1
Netfinity ServeRAID-3L Ultra2 SCSI Adapter (i channel)
N/A1
PCI Fast/Wide Ultra SCSI Adapter (1 channel)
N/A1
Ultra SCSI Adapter (2 channel)
N/A1
Ultra2 SCSI Adapter (1 channel)
Networking3
1
N/A
Netfinity 10/100 Ethernet PCI Adapter 2
N/A1
Netfinity Gigabit Ethernet SX Adapter
IBM NETFINITY 4000R
1. The Netfinity 4000R does not support customer installation of adapters, HDDs,
memory, processors, or any other devices that must be installed inside the server. Nonstandard features must be installed at the factory. Contact your IBM Marketing
Representative for more information.
2. Netfinity 4000R contains a single channel Wide Ultra SCSI adapter with an internal 68pin connector supporting up to two internal HDDs and an external 68-pin high density
connector for attachment of a single external SCSI device.
3. Netfinity 4000R contains two integrated 10/100 PCI Ethernet controllers.
Updated 01/01/00
For the latest product & technical information, refer to the Information Sources on pages 1 and 2.
25
Netfinity 4000R Power, Monitor & Accessories
Part
Number
Description
Power1
6952301
6 ft US (Chicago) Power Cord2
6952300
9-foot Power Cord2
94G6667
Power Cable Type A14 (4.3m, 14 ft.)2
94G7448
Power Cable Type C12 (3.7m, 12 ft.)3
94G6666
100-120V Power Distribution Unit4
94G7450
200-240V Power Distribution Unit5
94G6674
APC Smart-UPS 1400RMB6
94G6676
APC Smart-UPS 3000RMB7
65464AN
G54 Color Monitor 15” (13.7” Viewable Image Size), stealth black9
9513AG1
T55A Flat Panel Color Monitor (15.0” Viewable Image Size), stealth
black10
930842P
Netfinity Enterprise Rack
Power Distribution Units (PDU)
Uninterruptible Power Supply (UPS)
Monitors8
Rack and NetBay11
930842X
Netfinity Enterprise Expansion Cabinet
9306900
Netfinity Rack12
36L9703
Netfinity Rack Extension Kit
9306200
Netfinity NetBAY2212
36L9702
NetBAY22 Rack Extension Kit
Keyboard and Mouse13
28L3644
Space Saver II Keyboard14, 16
01K1260
TrackPoint IV 104-key Black Keyboard15, 16
28L3621
Preferred Keyboard (stealth black)15
28L3673
Sleek 2-Button Stealth Black Mouse
Console Options8
94G7445
Console Server Selector Switch (8-port)
28L0542
Netfinity Console Server Selector Switch (4-port)
94G7447
Console Cable Set - 12 ft. (3.66m)
1. Netfinity 4000R includes a single 150W power supply and a single 2.8 m (9 ft.) power cord with
an IEC 320-C14 connector on the outlet end.
2. For attachment to UPS part number 94G6674 or 94G6676, PDU part number 94G6666 or other
NEMA 5-15R outlet.
3. For attachment to PDU part number 94G7450 or other IEC 320-C13 outlet.
4. Requires optional power cord 6952301, 6952300 or 94G6667. Contains eight NEMA 5-15R
outlets and one communication link, Supports up to 12 amps.
5. Contains ten IEC 320-C13 outlets and three communication links, Supports up to 16 amps.
6. Requires optional power cord 6952301, 6952300 or 94G6667. Height is 3U. See “Rack and
NetBAY” for supported IBM racks. Contains six NEMA 5-15R outlets.
7. Requires optional power cord 6952301, 6952300 or 94G6667. Height is 3U. See “Rack and
NetBAY” for supported IBM racks. Contains eight NEMA 5-15R outlets.
8. A single Console Cable Set (P/N 947447) and an available port on a console switch is required
for each Netfinity 4000R.
9. Installation within a rack requires optional Monitor Compartment (P/N 94G7444).
10. Installation within a rack requires optional Netfinity Flat Panel Monitor Rack Mount Kit
(P/N 37L6857) and Netfinity Rack Keyboard Tray (P/N 28L4707). A space saver keyboard may
coexist within the same 28L4707 keyboard tray.
11. Netfinity 4000R is housed in a 19” rack mountable drawer and requires one of the racks listed
here. See IBM Netfinity Rack cabinet and Options section for IBM rack supported devices. To
provide adequate cooling, rack front door must be removed.
12. Rack Extension kits 36L9703 and 36L9702 are recommended for 9306900 and 9306200
respectively, to provide sufficient room for cable management.
13. Netfinity 4000R does not include a keyboard or mouse.
14. Installation within a rack requires optional keyboard tray P/N 28L4707 (stows in “ready-to-use”
position).
15. Installation within a rack requires optional keyboard tray P/N 28L4707. This keyboard cannot
share a keyboard tray with a flat panel display.
16. Advanced TrackPoint IV features are not available on IBM Netfinity systems.
26
IBM NETFINITY 4000R
Updated 01/01/00
For the latest product & technical information, refer to the Information Sources on pages 1 and 2.
27
IBM Netfinity 5000 Configurator
)
VD
)
, L ail)
s) d)
or
ax
D
n
s
v
I
)
r
s
/M
)
x)
ax , Fa nda
RA tal/A
ce
td
a
M
,
M
D
o
S
/
r
(
/M
D
IM
ta
td
tra To
td
tP
s)
(S s, H l, S
ive
Ul ys (
RD
(S
en
=
z)
bp
Dr
ity Slot iona
al, Ba
m
rs )
H
t
R
M
k
u
(
o
e
(
s
g
(M
an r,
B x)
il) ail)
(D i a
pt
ss
et
Di
na
v
)
va
Qu we (O
e d o c e e ( K / Ma
d
er ed
rn
r
ar
l/A tal/A
Ma the
ly (Po cy
r
DE
h td
pe
o ll le M
r
I
a
r
p
c
H
P
(
o
S
n
t
t
be
t
m
p
l
a
E
f
b
o
r
a
p
n
o
(S
c
e
u
a
T
o
a
C
T
m
o
M
d
a
t
o
d
y
(
r
s
r
s
O
C ov
:
Fa
rn
:(
r S Sw un
ar
Nu
es
-R
be EC C emo
Sy
te
ys lots
SI em
bo
rm
rt
we ot- Red
m
In
v.
oc
CD
S
Ba
SC R
H
M
Fo
On
Pa
L2
Po
Pr
Nu
Ad
8659-41Y
5004
1/2
512
128 MBR/2 GB
4
1/2
512
128 MB /2 GB
8659-51Y
5504
1/2
512
128 MBR/2 GB
8659-5RY1
5504
1/2
512
128 MBR/2 GB
8659-61Y
6004
1/2
512
128 MBR/2 GB
8659-6RY1
6004
512
MBR/2
8659-4RY
1
500
1/2
R
128
GB
H
S-Power2
Y
10/100
D,U
3/1
0/91 GB
32X- 14X3
8/6
5/5
H
S-Power
2
Y
10/100
D,U
3/1
0/91 GB
32X- 14X3
8/6
5/5
1/2
H
S-Power2
Y
10/100
D,U
3/1
0/91 GB
32X- 14X3
8/6
5/5
Rack(5U) 1/2
H
S-Power2
Y
10/100
D,U
3/1
0/91 GB
32X- 14X3
8/6
5/5
H
S-Power2
Y
10/100
D,U
3/1
0/91 GB
32X- 14X3
8/6
5/5
H
S-Power2
Y
10/100
D,U
3/1
0/91 GB
32X- 14X3
8/6
5/5
Tower
1/2
Rack(5U) 1/2
Tower
Tower
1/2
Rack(5U) 1/2
1. Housed in a 19” Rack mountable drawer and ships standard without a keyboard or mouse. See “Rack and NetBAY” under “Netfinity 5000 Power, Monitor & Accessories” for
supported IBM racks.
2. Robust configurations may require optional Netfinity 175W Redundant Power Supply (P/N 10L7007) for redundancy. See the Netfinity 5000 Power Supply Redundancy
Requirements table for additional information.
3. Variable read rate. Actual playback speed will vary and is often less than the maximum possible.
4. Intel Pentium III processor.
Netfinity 5000 Processor Upgrades
Part
Number
Processor Upgrades with 512 KB Cache
SMP
Support1
Processor Speed Upgrade2
10L5883
Netfinity 350/100 MHz, 512 KB Processor Upgrade with Pentium II Processor
All 1xY
-
10L5884
Netfinity 400/100 MHz, 512 KB Processor Upgrade
All 2xY
All 1xY
10L5900
Netfinity 450/100 MHz, 512 KB Processor Upgrade with Pentium II Processor
All 3xY
All 1...2xY
36L9673
Netfinity 500 MHz/512 KB Upgrade with Pentium III Processor
All 4xY
All 1...3xY
33L5112
Netfinity 550 MHz/512 KB Upgrade with Pentium III Processor
All 5xY
All 1...4xY
33L5106
Netfinity 600 MHz/512 KB Upgrade with Pentium III Processor
All 6xY
-
1. One additional processor may be installed, providing a maximum of two. All processors must be identical in type, speed, and cache size.
2. Requires removal of the standard processor. A maximum of two processors may be installed. All processors must be identical in type, speed and cache size. Upgrades may require a
BIOS update. To obtain the latest Flash BIOS, access www.ibm.com/pc/support and enter machine “Type-Model” in Quick Path. Select “Downloadable files” and then “BIOS”.
28
Total
Memory1
RDIMM Socket - J15
Std. RDIMM
Models 1...3xY
64 MB
64 MB RDIMM Standard
128 MB
1 x 01K7241
Model 4...6xY
128 MB RDIMM Standard
RDIMM Socket - J16
192 MB
1 x 01K7262
1 x 01K7241
RDIMM Socket - J17
256 MB
1 x 01K7262, 1 x 01K7241
1 x 01K7262
RDIMM Socket - J22
Part
Number
Memory Description
320 MB
1 x 01K8043
1 x 01K7262, 1 x 01K7241
384 MB
1 x 01K8043, 1 x 01K7241
1 x 01K8043
512 MB
1 x 01K8043, 1 x 01K7262, 1 x 01K7241
1 x 01K8043, 1 x 01K7262
576 MB
1 x 01K7263
01K7241
Netfinity 64 MB SDRAM ECC RDIMM
640 MB
1 x 01K7263, 1 x 01K7241
-
01K7262
Netfinity 128 MB SDRAM ECC RDIMM
1088 MB
2 x 01K7263
01K8043
Netfinity 256 MB SDRAM ECC RDIMM
1152 MB
2 x 01K7263, 1 x 01K7241
01K7263
Netfinity 512 MB SDRAM ECC RDIMM
1600 MB
3 x 01K7263
1 x 01K7263
2 x 01K7263
-
1664 MB
-
2048 MB
(max)
IBM NETFINITY 5000
Netfinity 5000 Memory
3 x 01K7263
4 x 01K72632
4 x 01K72632
This table does not represent all possible memory configurations.
1. Network Operating Systems may limit the maximum amount of addressable memory. See operating system
specifications for further information.
2. Replace standard RDIMM.
Netfinity 5000 Hard Disk Drive (HDD) Storage
Total Int.
Storage1
7200RPM Hard Disk Drives
(HDDs)
9.1 GB
0 GB
9.1 GB
18.2 GB
36.4 GB
10,000RPM Hard Disk Drives
(HDDs)
9.1 GB
Standard on Base Models
1 x 01K8053
-
-
1 x 36L9806
18.2 GB
2 x 01K8053 or 1 x 02K0440
-
2 x36L9806 or
27.2 GB
3 x 01K8053
-
3 x 36L9806
-
36.4 GB
4 x 01K8053 or 2 x 02K0440 or
45.5 GB
5 x 01K8053
-
54.6 GB
-
3 x 02K0440
72.8 GB
-
4 x 02K0440 or
91 GB (max)
-
5 x 02K0440
18.2 GB
36.4 GB
Standard on Base Models
1 x 02K0441
-
4 x36L9806 or
5 x 36L9806
-
-
1 x36L9807
-
2 x 36L9807 or
1 x 36L9808
-
-
-
-
3 x 36L9807
-
2 x 02K0441
-
4 x 36L9807 or
2 x 36L9808
-
-
5 x 36L9807
This table does not represent all possible hard drive configurations.
1. Total Internal Storage listed is within + 0.2 GB unless otherwise noted.
Updated 01/01/00
For the latest product & technical information, refer to the Information Sources on pages 1 and 2.
29
Bay
Form
Factor
Height
Front
Access
Usage
A
5.25”
HH1
Yes
Open2
B
5.25”
HH1
Yes
IDE CDROM
Part
Number
Description
RPM
Height
Bays
Max.
Supported Qty.
Internal Hard Disk
Drives (HDD)
01K8053
Netfinity 9.1 GB Wide Ultra SCSI
SCA-2 SL HDD
7200
SL
1...5
5
7200
SL
1...5
5
C
3.5”
SL
Yes
Diskette
02K0440
Netfinity 18.2 GB Wide Ultra SCSI
Hot-Swap SL HDD
1...5
HS1
SL3
Yes
Open
02K0441
Netfinity 36.4 GB Wide Ultra SCSI
Hot-Swap HDD
7200
HH1
1/2, 2/3, 3/4, 4/5
2
36L9806
Netfinity 9.1 GB 10K-3 Wide Ultra
SCSI Hot-Swap SL HDD
10,000
SL
1...5
5
36L9807
Netfinity 18.2 GB 10K-3 Wide
Ultra SCSI Hot-Swap SL HDD
10,000
SL
1...5
5
36L9808
Netfinity 36.4 GB 10K-3 Wide
Ultra SCSI Hot-Swap HDD
10,000
HH1
1/2, 2/3, 3/4, 4/5
2
1. Definitions: Half High (HH), Slim-Line (SL), Hot-Swap (HS)
2. Removable Media (RM) devices only.
3. Two slim-line (SL) can be combined to support a single half-high device.
External Storage
Expansion Units2
Bay 4
Bay 3
Bay 2
Bay 1
CD-ROM
Bay 5
Diskette
Bay A
Form
Factor
35202RU
Netfinity EXP15 Storage
Expansion Unit
Rack
(3U)
35301RU
Netfinity EXP200 Storage
Expansion Unit
Rack
(3U)
37L5857
Netfinity EXP200 Rack-to-Tower
Conversion Kit
-
1. Two slim-line (SL) bays can be combined to support a single half-high (HH) device.
2. Not supported by the onboard external SCSI port. Select an optional SCSI controller then refer to see
Appendix D: Cables-Storage Units-Controllers to confirm the controller supports the desired External Storage
Expansion Unit and to select a supported cable. For HDD or other expansion unit options, see the specific
expansion unit section.
Internal SCSI Cabling
Netfinity 5000 systems contain a backplane supporting five hot-swap drive bays. The backplane has an integrated SCSI terminator and is connected to one of the
two integrated dual-channel SCSI controller connectors by a two drop 16-bit SCSI cable. The second drop is available for supporting an internal removable media
device. In the event the standard two drop cable is attached to a RAID controller and a dedicated removable media attachment to the onboard controller is required,
an optional, terminated, 16-bit cable is available (Netfinity Two-Drop Internal SCSI Cable P/N 36L9636). The second SCSI channel is available for external device
attachment through a rear panel 68-pin high density connector.
30
1...5
Storage Controllers1
01K7364
Netfinity ServeRAID-3L Ultra2 SCSI Adapter2, 3
Full
32-bit
37L6086
Netfinity ServeRAID-3HB Ultra2 SCSI Adapter4
Full
32/64-bit
1...5
02K3454
PCI Fast/Wide Ultra SCSI Adapter
Half
32-bit
1...5
01K7297
Netfinity Fibre Channel PCI Adapter5
Half
32/64-bit
1...5
09L2123
Advanced SerialRAID/X Adapter6
Full
32-bit
1...57
Networking8
IBM NETFINITY 5000
Slots
Supported
Slot 1- PCI/ISA, Full Length
PCI
Support
Slot 2- PCI/ISA, Full Length
Adapter
Length
Slot 3- PCI, 32-bit, Full Length
Description
Slot 4- PCI, 32-bit, Full Length
Part
Number
Slot 5- PCI, 32-bit, Full Length
Netfinity 5000 I/O Options
Ethernet
34L1501
Netfinity 10/100 Ethernet PCI Adapter 2
Half
32-bit
1...5
08L3341
Netfinity 10/100 Fault Tolerant Adapter
Half
32-bit
1...5
Netfinity Gigabit Ethernet SX Adapter
Half
32/64-bit
1...5
34L0301
Token Ring
34L0501
Token-Ring 100/16/4 High-Speed PCI Adapter
Half
32-bit
1...5
34L0601
Token-Ring 16/4 PCI Adapter 2
Half
32-bit
1...5
33L4618
PCI V.90 56 Data/Fax Modem9
Half
32-bit
1, 2, 3
37L1414
Serial I/O SST8P DB Adapter10
Half
32-bit
1...510
Communications
37L1415
Serial I/O SST16P RJ Adapter10
Half
32-bit
1...510
37L1423
Serial I/O SST16P DB Adapter10
Half
32-bit
1...510
37L1416
Serial I/O SST128P Expandable Adapter10
Half
32-bit
1...510
Full
32-bit
1...513
-
-
-
-
-
-
Full
32-bit
1...517
Systems Management11
01K7209
Netfinity Advanced System Management PCI Adapter12
Kit14
03K9309
Netfinity Advanced System Management Interconnect Cable
36L9654
Netfinity Advanced System Management Token-RIng Connection15
Host Attach
9086001
Netfinity ESCON Adapter16
1. Netfinity 5000 has two integrated Wide Ultra SCSI channels. One is internal and the other is external with a 68-pin High Density connector.
2. All ServeRAID-3x adapters can be upgraded with the same enhanced software utilities and firmware included with ServeRAID-3HB. The download is available for no charge from
www.ibm.com/pc/support. Select “Server” in Brand pulldown, “ServeRAID” in Family pulldown and then “Downloadable files”. The upgrade should be considered for installations with
firmware less than Version 3.5.
3. Netfinity ServeRAID-3L Ultra2 SCSI Adapter (P/N 01K7364) provides either one internal or one external (0.8-mm VHDCI) LVDS SCSI channel.
4. Netfinity ServeRAID-3HB Ultra2 SCSI Adapter (P/N 37L6086) provides one internal and 2 external (0.8-mm VHDCI) LVDS SCSI channels. The internal channel can be configured for
external usage (0.8-mm VHDCI) providing a total of 3 external LVDS SCSI channels. Includes 32MB of mirrored battery-backup cache which helps protect against data loss in writeback cache mode in the event of a power outage or adapter maintenance.
5. See Netfinity Fibre Channel Solutions section for additional configuration information.
6. Requires system BIOS level of 7.0 or higher which can be found on BIOS Flash Update Diskette version 1.04 or higher. To obtain the latest Flash BIOS, access www.ibm.com/pc/
support and enter machine “Type-Model” in Quick Path. Select “Downloadable files” then “BIOS”.
7. A maximum quantity of four is supported.
8. Netfinity 5000 has an integrated 10/100 PCI Ethernet Controller.
9. Due to homologation variances, modem availability may differ by country.
10. See Appendix E for details on Serial I/O options and configuration limitations. A maximum of four Serial I/O adapters (any combination of P/N 37L1414, 37L1415, 37L1416, 37L1423)
may be installed.
11. The Netfinity Advanced Systems Management Processor and Interconnect Bus integrated into Netfinity 5000 works with Netfinity Manager to provide significant system
management function. When used with optional Netfinity Advanced System Management PCI Adapter (P/N 01K7209) and Netfinity Advanced System Management Interconnect Cable
Kit (P/N 03K9309) additional management and control of up to 12 service processors from a remote console through a single modem or LAN connection is possible.
12. Includes PCI adapter, Netfinity Advanced System Management Interconnect Cable Kit components and 56-watt AC adapter which requires a separate power source. Provides an
integrated 10/100 Ethernet port and PCMCIA slot to support optional Netfinity Advanced System Management Token-Ring Connection (P/N 36L9654).
13. A maximum quantity of one is supported.
14. Required for all Netfinity servers containing a standard Advanced System Management Processor that are to be interconnected for system management support through a LAN or
modem connection (Netfinity 5500 models 8660- 1...4xU are not supported). Optional Netfinity Advanced System Management PCI Adapter (P/N 01K7209) includes the content of this
option. Up to 12 service processors may be interconnected (including standard and optional processors) with an aggregate connec tion length of no more than 91.4 meters (300 ft.). A
customer-supplied Ethernet cable is required for each interconneciton.
15. Contains an IBM Turbo 16/4 Token-Ring PCI Card, which installs in the PCMCIA card slot of Netfinity Advanced System Managem ent PCI Adapter (P/N 01K7209), and a PC Card to
9-pin D-Shell cable which is routed to a rear chassis cut-out. The Netfinity Advanced System Management PCI Adapter integrated Ethernet port and Netfinity Advanced System
Management Token-Ring Connection cannot be connected or used together.
16. Provides an ESCON MIC and DB9 Serial Port. Cables are not included but are available through S/390 channels. Contact your IBM representative for additional information.
17. A maximum of two 9086001 adapters (installed in non-adjacent slots) are supported in a single Netfinity server.
Updated 01/01/00
For the latest product & technical information, refer to the Information Sources on pages 1 and 2.
31
Netfinity 5000 Power, Monitor & Accessories
Part Number
Description
Part Number
Power1
10L7007
Netfinity 175 W Redundant Power Supply
Uninterruptable Power Supply (UPS)2
94G3135
10L6972
Netfinity 5000 Rack-to-Tower Conversion Kit
10L7006
Netfinity 5000 Tower-to-Rack Conversion Kit
Rack and NetBAY1
APC Smart-UPS 1000 (19 min. runtime at 330 Watts)
94G3136
APC Smart-UPS 1400 (30 min. runtime at 330 Watts)
930842P
Netfinity Enterprise Rack
94G6674
APC Smart-UPS 1400 RMB (23 min. runtime at 330
Watts)3
930842X
Netfinity Enterprise Expansion Cabinet
94G6676
APC Smart-UPS 3000 RMB (62 min. runtime at 330
Watts)3
9306900
Netfinity Rack
9306200
Netfinity NetBAY22
65464AN
G54 Color Monitor 15” (13.7” Viewable Image Size),
stealth black4
65474AN
G74 Color Monitor 17” (15.9” Viewable Image Size),
stealth black4
28L3644
Space Saver II Keyboard3, 5
65494AN
G96 Color Monitor 19” (17.9” Viewable Image Size),
stealth black5
01K1260
TrackPoint IV 104-Key Black Keyboard4, 5
9513AG1
T55A Flat Panel Color Monitor (15.0” Viewable Image
Size), stealth black6
28L3621
Preferred Keyboard (stealth black)4
28L3673
Sleek 2-Button Stealth Black Mouse
Monitors
1. Netfinity 5000 includes redundant 175W power supplies within a single 350W unit.
This 350W unit is sufficient to operate fully configured systems, however optional
Netfinity 175W Redundant Power Supply (P/N 10L7007) is required to preserve N+1
redundancy if any of the following are exceeded:
- 512 MB of memory
- Three hard disk drives and/or tape drives
- Two PCI or ISA adapters
Netfinity 175W Redundant Power Supply (P/N 10L7007) includes a power cord which
requires an additional power source. An independent power source such as a 2nd
UPS or 2nd circuit is not required.
2. Stated runtimes and power are for typical configurations (approximately 70% of
maximum capacity). For additional information, see Appendix C: UPS Runtime
Estimate.
3. Height is 3U. See “Rack and NetBAY” for supported IBM racks.
4. Installation within a rack requires optional Monitor Compartment (P/N 94G7444).
5. Not supported for installation in a 19” rack.
6. Installation within a rack requires optional Netfinity Flat Panel Monitor Rack Mount
Kit (P/N 37L6857) and Netfinity Rack Keyboard Tray (P/N 28L4707). A space saver
keyboard may coexist within the same 28L4707 keyboard tray.
32
Description
Conversion Kits
Keyboard and Mouse2
1. Netfinity 5000 rack models are housed in a 19” rack mountable drawer and require one of the
racks listed here. See IBM Netfinity Rack Cabinet and Options section for IBM rack supported
devices.
2.Tower models include both a mouse and keyboard. Rack models include neither.
3. Installation within a rack requires optional keyboard tray P/N 28L4707 (stows in “ready-to-use”
position).
4. Installation within a rack requires optional keyboard tray P/N 28L4707. This keyboard cannot share
a keyboard tray with a flat panel display.
5. Advanced TrackPoint IV features are not available on IBM Netfinity systems.
Part
Number
01K1282
Description
12/24 GB DDS/3 4-mm Internal Tape Drive
Bays
Supported
SCSI
Interface
(bit)
A
8
Form Termination
Factor
Included
68/50-pin
Converter
Incl.
Ext. Tape
Enclosures1
3.5” HH or
5.25” HH
3.5” SL or
5.25” HH
3.5” HH or
5.25” HH
Y2
Y
3510020
2
Y
3510020, 3551001
Y2
N
3510020, 3551001
01K1319
10/20 GB NS Internal SCSI Tape Drive
A
8
Y
00N7991
20/40 GB DDS/4 4-mm Internal Tape Drive
A
16 Ultra2 LVD
01K1325
20/40 GB 8-mm Internal SCSI Tape Drive
A
16
5.25” HH
N3
N
01K1320
20/40 GB DLT Internal SCSI Tape Drive
N/A10
8
5.25” FH
Y2
Y
04K0149
35/70 GB DLT Internal SCSI Tape Drive
N/A10
16
5.25” FH
N
N
00N7990
40/80 GB DLT Internal SCSI Tape Drive
N/A10
16 LVD
5.25” FH
N
N
35100204,
3551001
3503B0X,
3551001
3503B0X4,
3551001
3503B0X4,
3551001
Associated Options
32G3918
SCSI-2 16-bit Active Terminator
-
16
External
Y
N
36L9636
Netfinity Two-Drop Internal SCSI Cable5
-
16
Internal
Y
N
3503B0X
3510020
-
-
8/16
16
16
16
Desktop
Rack
Desktop
N
Y
N
N
N
N
N
N
3551001
-
DLT Tape Autoloader
DLT8000 Tape Autoloader
-
16
16 LVD
Y
Y
-
-
3503x14
DLT8000 Tape Library
-
16 LVD
Desktop
Desktop
Desktop or
Rack
Y
-
-
3570xxx
Magstar MP 3570 Tape Subsystem
(models B2x and C2x)
-
Diff.
Rack
Y
-
-
External Tape Enclosures
3510020
3551001
10L7113
3503B0X
External Half High SCSI Storage Enclosure6
NetMEDIA Storage Expansion Unit EL7
NetMEDIA Systems Management Adapter9
DLT External SCSI Enclosure11
External Tape Libraries8
3502108
3503108
1. To determine cable requirements, note the tape drive’s SCSI interface, the appropriate SCSI controller from the system configurator section, and the desired enclosure, then refer to
Appendix D: Cables-Storage Units-Controllers.
2. Tape drive is capable of self termination.
3. Termination is provided by the system unit’s standard SCSI cabling.
4. Requires SCSI-2 16-bit Active Terminator (P/N 32G3918).
5. Netfinity Two-Drop Internal SCSI Cable (P/N 36L9636) is a wide two-drop terminated cable and is required for attachment of internal tape drives to the onboard SCSI controller of a Netfinity
5000 when the hot-swap backplane is attached to a RAID controller.
6. Provides a black desktop 5.25” half-high (HH) tape enclosure. Connector is configurable as 50-pin Centronix or 68-pin high density. Requires either tape drive self termination or SCSI-2
16-bit Active Terminator (P/N 32G3918).
7. Provides a black 3U, 19” rack or NetBAY3 mountable tape enclosure. Provides two full high (FH) or four half high (HH) extended length 5.25” bays. External connector is 0.8-mm VHDCI.
Includes two power supplies and two power cords.
8. Tape library attributes and prerequisites are located in Appendix B: Tape Library Attributes.
9. Installs in 3551001. Provides repeater function and LVDS interface allowing longer cable lengths and auto-termination when t he 3551001 is powered off.
10. Supported in an external tape enclosure only.
11. Provides a black desktop DLT tape enclosure with a 68-pin high density external connector. Requires termination by the tape drive or by installation of a SCSI-2 16-bit Active Terminator
(P/N 32G3918)
NOTE: SCSI support for tape drives is provided by system unit onboard (standard) controller (no-RAID function) or PCI Fast Wide Ultra SCSI Adapter P/N 02K3454. When standard cabling is
connected to a RAID controller, tape drives must utilize terminated Netfinity Two-Drop Internal SCSI Cable (P/N 36L9636), and attach to the onboard or other supported controller. Additional
tape attributes can be found in Appendix A: Tape Drive Attributes.
For a complete list of all IBM and non-IBM option compatibility with Network Operating Systems and IBM Netfinity Servers, access the ServerProven™ compatibility pages on the Web at URL
www.ibm.com/pc/us/compat.
Updated 01/01/00
For the latest product & technical information, refer to the Information Sources on pages 1 and 2.
33
IBM NETFINITY 5000
Netfinity 5000 Tape Options
Sample Configurations
Note: The following sample configurations are for illustration only and may not be suitable for any specific customer installation. Contact your IBM Business Partner
or IBM Marketing Representative for assistance with your specific configuration requirements.
Internet Server
Part Number
8659-51Y
01K7241
01K7364
01K8053
01K1325
36L9636
65464AN
94G3135
10L7007
Description
Netfinity 5000 (Pentium III 550/128 MB/Open Bay)
Netfinity 64 MB SDRAM ECC RDIMM1
Netfinity ServeRAID-3L Ultra2 SCSI Adapter
Netfinity 9.1 GB Wide Ultra SCSI SCA-2 SL HDD2
20/40 GB 8-mm Internal SCSI Tape Drive
Netfinity Two-Drop Internal SCSI Cable
G54 Color Monitor 15” (13.7” Viewable Image Size), stealth black
APC Smart-UPS 1000
Netfinity 175 W Redundant Power Supply
Quantity
1
1
1
4
1
1
1
1
1
1. For a total of 192 MB of system memory.
2. For a total of 36.4 GB of RAID protected Hot-Swap, Hot-Spare internal storage.
An Internet server is a server that handles all requests from the Internet (intranet or extranet). Usually, this type of server has the same characteristics as a file server.
The main difference is that an internet server talks a different language (TCP/IP vs. NETBEUI or IPX/SPX) and often needs to do an extra security check (Firewall). In
the case of an Internet server, the server itself talks mostly to just one client, the Internet Service Provider (ISP), instead of many clients like a file server does.
With this in mind the IBM Netfinity 5000 was selected to provide an affordable price point for the growing internet server market with two way Pentium II processing,
192 MB of system memory (expandable to 2 GB), and availability features such as RAID protected internal hot-swap storage and power protection with an APC
Smart-UPS.
The network configuration depends on the method that will be used to connect the server to the Internet. Usually fast Ethernet routers are used, but if other methods
are used, you can add the appropriate adapter. The configuration includes a tape backup unit for secure backup of critical data in the event of a system or storage
failure.
File and Print Server
Part Number
Description
8659-41Y
Netfinity 5000 (Pentium III 500/128 MB/Open Bay)
01K7241
Netfinity 64 MB SDRAM ECC RDIMM1
01K7364
Netfinity ServeRAID-3L Ultra2 SCSI Adapter
01K8053
Netfinity 9.1 GB Wide Ultra SCSI SCA-2 SL HDD2
01K1325
20/40 GB 8-mm Internal SCSI Tape Drive
36L9636
Netfinity Two-Drop Internal SCSI Cable
65464AN
G54 Color Monitor 15” (13.7” Viewable Image Size), stealth black
94G3135
APC Smart-UPS 1000
1. For a total of 192 MB of system memory.
2. For a total of 45.5 GB of RAID protected Hot-Swap, Hot-Spare internal storage.
Quantity
1
1
1
5
1
1
1
1
A small business or departmental server is usually required to perform all typical server functions while servicing up to 100 users in a normal workgroup computing
environment, but doesn’t require the high-end performance and fault tolerance properties of larger servers.
The sample configuration above consists of an IBM Netfinity 5000 with 192 MB of memory and 45.5 GB of hard disk space. It has enough processor power and
memory to run most current network operating systems comfortably and enough hard disk drive space to store a significant amount of data with additional external
storage expansion still available. Demanding network traffic is effectively handled by the standard 100 Mbps Ethernet connection. This configuration also includes a
tape backup unit, monitor, and a UPS to keep the system protected during power surges and outages.
34
IBM NETFINITY 5000
Rack Mounted Application Server
Part Number
8659-6RY
33L5106
01K8043
37L6086
36L9806
01K1325
36L9636
65464AN
94G6674
10L7007
Description
Netfinity 5000 (Pentium III 600/128 MB/Open Bay/Rack)
Netfinity 600 MHz/512 KB Upgrade with Pentium III Processor
Netfnity 256 MB SDRAM ECC RDIMM1
Netfinity ServeRAID-3HB Ultra2 SCSI Adapter
Netfinity 9.1 GB 10K-3 Wide Ultra SCSI Hot-Swap SL HDD2
20/40 GB 8-mm Internal SCSI Tape Drive
Netfinity Two-Drop Internal SCSI Cable
G54 Color Monitor 15” (13.7” Viewable Image Size), stealth black
APC Smart-UPS 1400RMB
Netfinity 175 W Redundant Power Supply
Quantity
1
1
1
1
5
1
1
1
1
1
Industry Standard 19” Rack, EIA-310D, Min. depth of 28” (711 mm)
9306200
Netfinity NetBAY22
28L3644
Space Saver II Keyboard
94G6670
Blank Filler Kit
1. For a total of 384 MB of system memory.
2. For a total of 36.4 GB usable RAID 5 storage (45.5GB total disk).
1
1
2
An application server differs from a file and print server in that it has a higher workload, in providing application serving requirements for users. With this in mind the
IBM Netfinity 5000 was selected to provide an affordable price point for an application server, with two-way Pentium III processing, 384 MB of system memory
(expandable to 2 GB), and availability features such as battery-backed cache RAID protected internal Hot-Swap storage and power protection with an APC SmartUPS.
Updated 01/01/00
For the latest product & technical information, refer to the Information Sources on pages 1 and 2.
35
IBM Netfinity 5500 Configurator
)
VD
or
, L ail.) ax)
s)
ss
)
D
n
e
)
I
)
d
2
a
A
/M
Av
oc
ax
ar
ax D, F
, R tal/ Std
M)
Pr
nd
/M
d/M
D
IM
nt ps)
ta
td
tra (To es (
H
l
St
D
e
S
S
,
(
U ys
)
l,
s
=R
y ( lots
l,
e m ( Mb
r iv
Hz or )
na
(R
tit
u a Ba k D
t
ag
S
(M ess (KB x.)
tio
)
an
l)
r,
( D d ia
s
a n r ne
i
p
u
d
e
a
r
c
.
ail vai
M
D
e
O
e
o
l l e Me r d
r
y Q (Pow
E)
m Eth
pe f Pr che td./M
y(
r
/Av al/A
l
o
l
D
e
c
r
a
S
o
p
e
I
be
t
a
a
(
t
p
t
H
p
nt
bl
ct
m
an
ys ar d
or r o C C y (S
To : (To
Fa r Su Swa
Co va nal
r
o
nd
ss be
OM
Nu
.S
:(
-R
tSI emo ter
du
ce um 2 EC emo
rt
dv Onb
rm owe
ys lots
o
D
e
a
o
C
o
A
a
n
r
L
N
H
P
F
C
R
I
R
S
S
B
P
M
P
8660-61U
5007 1/2 512
128 MB (R) /1GB
8660-6RU1
5007 1/2 512
128 MB (R) /1GB
8660-62U8
5007 1/2 512
256 MB (R) /1GB
8660-6SU1, 8
5007 1/2 512
256 MB (R) /1GB
8660-72U
5507 1/2 512
256 MB (R) /1GB
8660-7SU1
5507 1/2 512
256 MB (R) /1GB
S-Fans,
O-Power
Y
10/100
D,R
4/2
0/109 GB5
(32X-14X)6
10/8
7/7
1/2 P, S, H, F
S-Fans,
O-Power
Y
10/100
D,R
4/2
0/109 GB
(32X-14X)6
10/8
7/7
Tower4 1/2 P, S, H, F
S-Fans,
O-Power
Y
10/100
D,R
4/2
0/109 GB5
(32X-14X)6
10/8
7/7
1/2 P, S, H, F
S-Fans,
O-Power
Y
10/100
D,R
4/2
0/109 GB
(32X-14X)6
10/8
7/7
Tower4 1/2 P, S, H, F
S-Fans,
O-Power
Y
10/100
D,R
4/2
0/109 GB5
(32X-14X)6
10/8
7/7
S-Fans,
O-Power
Y
10/100
D,R
4/2
0/109 GB
(32X-14X)6
10/8
7/7
Tower4 1/2 P, S, H, F
Rack
(8U)
Rack
(8U)
Rack
(8U)
1/2 P, S, H, F
1. Housed in a 19” Rack mountable drawer and ships standard without a keyboard or mouse. See “Rack and NetBAY” under “Netfinity 5500 Power, Monitor & Acessories” for
supported IBM racks.
2. Netfinity 5500 models which have Netfinity Upgrade for Pentium II Xeon Processors (P/N 01K8049) installed have a maximum memory capacity of 2 GB. With Netfinity Four-Way
Processor Upgrade Kit (P/N 28L1014) the maximum memory is 4 GB.
3. The memory DIMM shipped with this model is NOT compatible with Registered DIMMs (RDIMMs), Netfinity Upgrade for Pentium II Xeon Processors (P/N 01K8049) or Netfinity
Four-Way Processor Upgrade Kit (P/N 28L1014) and must be replaced if either upgrade or a RDIMM is installed.
4. Tower models come equipped with a single NetBAY3, 3U stackable enclosure. Up to a maximum of three are supported.
5. With a single Netfinity EXP15 installed in the standard NetBAY3, the maximum internal storage increase by 364 GB.
6. Variable read rate. Actual playback speed will vary and is often less than the maximum possible.
7. Intel Pentium III Processor.
8. Not available in the USA.
Netfinity 5500 Processor Upgrades
Part Number
Processor Upgrades with 512 KB Cache
SMP Support1 Processor Speed/Cache
Upgrade2
10L5883
Netfinity 350 MHz, Upgrade with Pentium II Processor
All 1xU
-
10L5884
Netfinity 400/100 MHz, 512 KB Processor Upgrade
All 4xU
All 1xU
10L5900
Netfinity 450/100 MHz, 512 KB Processor Upgrade with Pentium II Processor
All 5xU
All 1...4xU
36L9673
Netfinity 500 MHz/512 KB Upgrade with Pentium III Processor
All 6xU
All 1...5xU
33L5112
Netfinity 550 MHz/512 KB Upgrade with Pentium III Processor
All 7xU
All 1...6xU
01K8049
Netfinity Upgrade for Pentium II Xeon Processors3
-
All3
28L1014
Netfinity Four-Way Processor Upgrade Kit4
-
All4
1. One additional processor may be installed, providing a maximum of two. All processors must be identical in type, speed, and cache size.
2. Requires removal of the standard processor. A maximum of two processors may be installed. All processors must be identical in type, speed and cache size. Upgrades may require a BIOS
update. To obtain the latest Flash BIOS, access www.ibm.com/pc/support and enter machine “Type-Model” in Quick Path. Select “Downloadable files” and then “BIOS”.
3. Provides required components for upgrading an IBM Netfinity 5500 to a 2-way SMP Pentium II Xeon processor capable system. Key components include: two slot 2 processor sockets,
440Gx Host Bridge Controller, four RDIMM memory sockets, four VRM sockets, and a terminator card. Components that are NOT included and must be ordered separately: processors and
memory. All Netfinity 5500 models require processor replacement. Standard memory DIMMs on models 8660-11U, 1RU, 41U, 4RU, 51U, and 5RU are not compatible and must be replaced.
Refer to Netfinity 5500 M10 configurator for option compatibility with any 5500 containing upgrade P/N 01K8049. A maximum of two processors may be installed. All processors must be
identical in type, speed and cache size. Upgrades may require a BIOS update. To obtain the latest Flash BIOS, access www.ibm.c om/pc/support and enter machine “Type-Model” in Quick
Path. Select “Downloadable files” and then “BIOS”.
4. Provides required components for upgrading an IBM Netfinity 5500 to a 4-way Pentium II Xeon or Pentium III Xeon SMP capable system. Installation of P/N 28L1014 prevents the use of PCI
slot 6 and shortens slot 5 to Half Length. Installation must be performed by an IBM trained servicer or IBM Customer Engineer. Installation is included in the purchase price. Key components
include: memory card ( 4 GB capacity), processor card assembly, power backplane, 500W power supply, assorted cables, LED card, and chassis hardware. Components that are NOT
included and must be ordered separately: processors, memory and 500W redundant power supply. All Netfinity 5500 models require processor replacement. Standard memory DIMMs on
models 8660-11U, 1RU, 41U, 4RU, 51U, and 5RU are not compatible and must be replaced. Refer to Netfinity 5500 M20 configurator for option compatibility with any 5500 containing upgrade
P/N 28L1014. A maximum of four processors may be installed. All processors must be identical in type, speed and cache size. Upgrades may require a BIOS update. To obtain the latest Flash
BIOS, access www.ibm.com/pc/support and enter machine “Type-Model” in Quick Path. Select “Downloadable files” and then “BIOS”.
36
Netfinity 5500 Memory
DIMM Models 8660-11U,
1RU, 41U, 4RU, 51U, 5RU
RDIMM Models
8660-61U, 6RU
RDIMM Models 8660-42U,
4SU, 52U, 5SU, 62U, 6SU,
7xU
128 MB
128 MB DIMM Standard
192 MB
1 x 01K8022
256 MB
1 x 01K8023
1 x 01K7262
256 MB RDIMM Standard
384 MB
2 x 01K8023
1 x 01K8043
1 x 01K7262
RDIMM Slot 3 - J2
512 MB
3 x 01K8023
1 x 01K7262, 1 x 01K8043
1 x 01K8043
2 x 01K8043, 1 x 01K72621
RDIMM Slot4 - J1
640 MB
2 x 01K8043
1 x 01K8043, 1 x 01K7262
768 MB
3 x 01K80431
1 x 01K7262, 2 x 01K8043
2 x 01K8043
896 MB
3 x 01K8043, 1 x 01K72621
3 x 01K8043
2 x 01K8043, 1 x 01K7262
4 x 01K80431
3 x 01K8043
1024 MB (max) 4 x 01K80431
128 MB RDIMM Standard
-
-
RDIMM Slot 1 - J4
-
RDIMM Slot 2 - J3
Standard (R)DIMM
This table does not represent all possible memory configurations.
1. Replace standard (R)DIMMs.
Part
Number
Memory Description
Models 8660-11U, 1RU,
41U, 4RU, 51U, 5RU
All Other
Models
Upgrade 01K8049 or 28L1014
-
01K8022
Netfinity 64 MB SDRAM ECC DIMM1
X
X3
01K8023
128 MB SDRAM ECC DIMM1
X
X3
-
01K7262
Netfinity 128 MB SDRAM ECC RDIMM1
X2
X
X4
01K8043
Netfinity 256 MB SDRAM ECC RDIMM1
X2
X
X4
1. DIMMs or RDIMMs must be installed in sequence beginning with slot 4 (J1) and ordered from largest to smallest.
2. Requires removal of standard DIMM. Cannot co-exist with 64 MB (P/N 01K8022) or 128 MB (P/N 01K8023) DIMMs.
3. Requires removal of standard RDIMM. Cannot co-exist with 128 MB (P/N 01K7262) or 256 MB (P/N 01K8043) RDIMMs.
4. Models with Netfinity Upgrade for Pentium II Xeon Processors (01K8049) installed should reference Netfinity 5500 M10 for compatibility and sample configurations. Models with
Netfinity Four-Way Processor Upgrade Kit (28L1014) installed should reference Netfinity 5500 M20 for compatibility and sample configurations.
Updated 01/01/00
For the latest product & technical information, refer to the Information Sources on pages 1 and 2.
37
IBM NETFINITY 5500
Total
Memory
Netfinity 5500 Hard Disk Drive (HDD) Storage
Total Int.
Storage1
7200 RPM Hard Disk Drives
(HDDs)
9.1 GB
0 GB
18.2 GB
10,000 RPM Hard Disk Drives
(HDDs)
36.4 GB
9.1 GB
Standard on Base Models
9.1 GB
1 x 01K8053
-
-
18.2 GB
2 x 01K8053 or 1 x 02K0440
27.2 GB
3 x 01K8053
-
36.4 GB
4 x 01K8053 or 2 x02K0440 or
45.5 GB
5 x 01K8053
54.6 GB
6 x 01K8053 or 3 x02K0440
72.8 GB
1 x 36L9806
2 x 36L9806 or
-
-
4 x 02K0440 or
91 GB
-
5 x 02K0440
109 GB(max)
-
6 x 02K0440 or
36.4 GB
-
4 x 36L9806 or
-
5 x 36L9806
-
6 x 36L9806 or
2 x 02K0441
-
-
1 x36L9807
3 x 36L9806
1 x 02K0441
-
18.2 GB
Standard on Base Models
-
-
-
2 x 36L9807 or
1 x 36L9808
-
-
3 x 36L9807
-
4 x 36L9807 or
-
-
5 x 36L9807
3 x 02K0441
-
6 x 36L9807 or
2 x 36L9808
3 x 36L9808
This table does not represent all possible hard drive configurations.
1. Total Internal Storage listed is within + 0.2 GB unless otherwise noted.
Bay
Form
Factor
Height
Front
Access
Usage
Part
Number
Description
RPM
Height
Bays
Max.
Supported Qty.
01K8053
Netfinity 9.1 GB Wide Ultra SCSI
SCA-2 SL HDD
7200
SL
1...6
6
7200
SL
1...6
6
Internal Hard Disk Drives
-
3.5”
SL
Yes
Diskette
-
5.25”
HH
Yes
IDE CD-ROM
02K0440
Netfinity 18.2 GB Wide Ultra
SCSI Hot-Swap SL HDD
A
5.25”
HH1
Yes
Open
02K0441
Netfinity 36.4 GB Wide Ultra
SCSI Hot-Swap HDD
7200
HH1
1/2, 3/4, 5/6
3
10,000
SL
1...6
6
B
5.25”
HH1
Yes
Open
36L9806
Netfinity 9.1 GB 10K-3 Wide
Ultra SCSI Hot-Swap SL HDD
1...6
HS
SL2
Yes
Open
36L9807
Netfinity 18.2 GB 10K-3 Wide
Ultra SCSI Hot-Swap SL HDD
10,000
SL
1...6
6
36L9808
Netfinity 36.4 GB 10K-3 Wide
Ultra SCSI Hot-Swap HDD
10,000
HH1
1/2, 3/4, 5/6
3
NB33
19” Rack
3U
Yes
Open
1. Two half-high (HH) bays can be combined to support a single full-high device.
2. Two slim-line (SL) bays can be combined to support a single half-high device.
3. One NetBAY3 is included with tower models and a total of three are supported.
See IBM Netfinity NetBAY3 Stackable Enclosure section for supported devices.
Removable
Media(RM)
Diskette
CD-ROM
Bay A
Bay B
Hot Swap
(HS)
Bay 1
Bay 2
Bay 3
Bay 4
Bay 5
Bay 6
Netfinity NetBAY3 (NB3)
(Tower Models Only)
External Storage
Expansion Units2
Form Factor
35202RU
Netfinity EXP15 Storage
Expansion Unit
Rack (3U)
35301RU
Netfinity EXP200 Storage
Expansion Unit
Rack (3U)
37L5857
Netfinity EXP200 Rack-toTower Conversion Kit
Tower
1. Two slim-line (SL) bays can be combined to support a single half-high (HH) device.
2. Supported by the onboard external SCSI port (requires Netfinity SCSI Controller Cable P/N 03K9313).
Select the onboard or optional SCSI controller then refer to Appendix D: Cables-Storage Units-Controllers to
confirm the controller supports the desired External Storage Expansion Unit and to select a supported
cable. For HDD or other expansion unit options, see the specific expansion unit section.
Internal SCSI Cabling
Netfinity 5500 and 5500 M10 systems contain a backplane supporting six hot-swap drive bays. The backplane is connected to one of the two connectors of the
integrated dual-channel ServeRAID controller through a 16-bit SCSI cable. A two-drop 16-bit SCSI cable, with an integrated terminator, is included with the server to
support up to two internal removable media devices connected to the second RAID connector or a supported SCSI adapter. Optional Netfinity SCSI Controller
Cable (P/N 03K9313) is a 16-bit cable that can be attached to the second RAID connector and routed to the rear panel cutout providing an external 16-bit VHDCI
0.8-mm connector. If internal removable media devices are required in addition to external RAID device attachment, a supported SCSI adapter must be installed
using the standard two-drop SCSI cable for device/adapter connection. If connecting narrow devices to this cable, additional 68-pin to 50-pin converters (P/N
32G3925) must be ordered. Some narrow devices include a converter in their ship group.
38
Netfinity 5500 I/O Options
Part
Number
Description
Adapter
PCI
Length Support
Slots
HotSupported1 Plug2
Netfinity ServeRAID-3L Ultra2 SCSI Adapter4, 5
Full
32-bit
1...6
X
37L6086
Netfinity ServeRAID-3HB Ultra2 SCSI Adapter6
Full
32/64-bit
1...6
X
02K3454
PCI Fast/Wide Ultra SCSI Adapter
Half
32-bit
1...6
-
01K7297
Netfinity Fibre Channel PCI Adapter7
Half
32/64-bit
1...6
-
09L2123
Advanced SerialRAID/X Adapter
Full
32-bit
1...68
-
Ethernet
34L1501
Netfinity 10/100 Ethernet PCI Adapter 2
Half
32-bit
1...6
X
08L3341
Netfinity 10/100 Fault Tolerant Adapter
Half
32-bit
1...6
X
Netfinity Gigabit Ethernet SX Adapter
Half
32/64-bit
1...6
X
34L0301
34L0501
Token-Ring 100/16/4 High-Speed PCI Adapter
Half
32-bit
1...6
-
34L0601
Token-Ring 16/4 PCI Adapter 2
Half
32-bit
1...6
X
33L4618
PCI V.90 56 Data/Fax Modem10
Half
32-bit
1...6
-
37L1414
Serial I/O SST8P DB Adapter11
Half
32-bit
1...611
-
37L1415
Serial I/O SST16P RJ Adapter11
Half
32-bit
1...611
-
37L1423
Serial I/O SST16P DB Adapter11
Half
32-bit
1...611
-
37L1416
Serial I/O SST128P Expandable Adapter11
Half
32-bit
1...611
-
Communications
Systems Management12
01K7209
Netfinity Advanced System Management PCI Adapter13
Full
32-bit
1...614
-
03K9309
Netfinity Advanced System Management Interconnect Cable Kit15
-
-
-
-
36L9654
Netfinity Advanced System Management Token-RIng Connection16
-
-
-
-
Full
32-bit
1...618
-
ISA, Full Length
Token Ring
Slot 1- PCI, Hot- Plug, 32-bit, Full Length
Slot 2- PCI, Hot- Plug, 32-bit, Full Length
Slot 3- PCI, Hot- Plug, 32-bit, Full Length
Slot 4- PCI, Hot- Plug, 32-bit, Full Length
Networking
9
Host Attach
9086001
Netfinity ESCON Adapter17
1. PCI Slots 1, 2, 3 and 4 support Hot Plug devices.
2. Hot Plug capable using IBM’s Active PCI Technology.. For Network Operating System support access URL www.ibm.com/pc/us/compat.
3. Netfinity 5500 and 5500 Mxx have a dual channel ServeRAID II Wide Ultra SCSI controller.
4. All ServeRAID-3x adapters can be upgraded with the same enhanced software utilities and firmware included with ServeRAID-3HB.The download is available for no charge from
www.ibm.com/pc/support. Select “Server” in Brand pulldown, “ServeRAID” in Family pulldown and then “Downloadable files”. The upgrade should be considered for installations with firmware
less than Version 3.5.
5. Netfinity ServeRAID-3L Ultra2 SCSI Adapter (P/N 01K7364) provides either one internal or one external (0.8 mm VHDCI) LVDS SCSI channel.
6. Netfinity ServeRAID-3HB Ultra2 SCSI Adapter (P/N 37L6086) provides one internal and 2 external (0.8mm VHDCI) LVDS SCSI chann els. The internal channel can be configured for external
usage (0.8 mm VHDCI) providing a total of 3 external LVDS SCSI channels. Includes 32 MB of mirrored battery-backup cache which helps protect against data loss in write-back cache mode
in the event of a power outage or adapter maintenance
7. See Netfinity Fibre Channel Solutions section for additional configuration information.
8. A maximum quantity of four is supported.
9. Netfinity 5500 and 5500 Mxx have an integrated 10/100 PCI Ethernet Controller.
10. Due to homologation variances, modem availability may differ by country.
11. See Appendix E for details on Serial I/O options and configuration limitations. A maximum of four Serial I/O adapters (any combination of P/N 37L1414, 37L1415, 37L1416, 37L1423) may be
installed.
12. The Netfinity Advanced System Management Processor and Interconnect Bus integrated into Netfinity 5500 (8660-5...6xU) and 5500 Mxx works with Netfinity Manager to provide
significant system management function. When used with optional Netfinity Advanced System Management PCI Adapter (P/N 01K7209) and Netfinity Advanced System Management
Interconnect Cable Kit (P/N 03K9309) additional management and control of up to 12 service processors from a remote console through a single modem or LAN connection is possible.
Systems managenment options P/N 01K7209, 03K9309 and 36L9654 are NOT supported by Netfinity 5500 models 8660-1...4xU.
13. Includes PCI adapter, Netfinity Advanced Systems Management Interconnect Cable Kit components and 56-watt AC adapter, which requires a separate power source. Provides an
integrated 10/100 Ethernet port and a PCMCIA slot to support optional Netfinity Advanced System Management Token-Ring Connection (P/N 36L9654). NOT supported by Netfinity 5500
models 8660-1...4xU.
14. A maximum quantity of one is supported.
15. Required for all Netfinity Servers containing a standard Advanced System Management Processor that are to be interconnected for system management support through a LAN or modem
connection (Netfinity 5500 models 8660 1...4xU are not supported). Optional Netfinity Advanced System Management PCI Adapter (P/N 01K7209) includes the contents of this option. Up to
12 service processors may be interconnected (including standard and optional processors) with an aggregate connection length of no more than 91.4 meters (300 ft.). A customer-supplied
Ethernet cable is required for each interconnection.
16. Contains an IBM Turbo 16/4 Token-Ring PCI Card, which installs in the PCMCIA card slot of Netfinity Advanced System Management PCI Adapter (P/N 01K7209), and a PC Card to 9-pin DShell cable which is routed to a rear chassis cut-out. The Netfinity Advanced System Management PCI Adapter’s integrated Ethernet port and Netfinity Advanced System Management TokenRing Connection cannot be connected or used together.
17. Provides an ESCON MIC and DB9 Serial Port. Cables are not included but are available through S/390 channels. Contact your IBM representative for additional information.
18. A maximum of two 9086001 adapters (installed in non-adjacent slots) are supported in a single Netfinity server.
Updated 01/01/00
For the latest product & technical information, refer to the Information Sources on pages 1 and 2.
39
IBM NETFINITY 5500
01K7364
Slot 5- PCI, 32-bit, Primary Bus, Full Length
Slot 6- PCI, 32-bit Primary Bus, Full Length
Storage Controllers3
Netfinity 5500 Power, Monitor & Accessories
Part
Number
Description
Part
Number
Power1
01K7951
94G3136
Conversion Kits
Netfinity 400 W Hot-Swap Redundant Power Supply II2
01K8021
Netfinity 5500 Rack-to-Tower Kit1
Uninterruptible Power Supply (UPS)3
01K8020
Netfinity 5500 Tower-to-Rack Kit
Rack and NetBAY2
APC Smart-UPS 1400 (26 min. runtime at 375 Watts)
Watts)4
94G6674
APC Smart-UPS 1400RMB (21min. runtime at 375
94G6676
APC Smart-UPS 3000RMB (55 min. runtime at 375 Watts)4
65464AN
G54 Color Monitor 15” (13.7” Viewable Image Size), stealth black5
Monitors
930842P
Netfinity Enterprise Rack
930842X
Netfinity Enterprise Expansion Cabinet
9306900
Netfinity Rack
9306200
Netfinity NetBAY22
65474AN
G74 Color Monitor 17” (15.9” Viewable Image Size), stealth black5
10L6912
Netfinity NetBAY33
65494AN
G96 Color Monitor 19” (17.9” Viewable Image Size), stealth black6
10L6913
Netfinity Caster Set
9513AG1
T55A Flat Panel Color Monitor (15.0” Viewable Image Size), stealth
black7
Cables
Keyboard and Mouse4
28L3644
8
Space Saver II Keyboard5,7
03K9313
Netfinity SCSI Controller Cable (0.8 mm)
01K1260
TrackPoint IV 104-Key Black Keyboard6,7
32G3925
SCSI 68-pin to 50-pin Converter
28L3621
Preferred Keyboard (stealth black)6
28L3673
Sleek 2-Button Stealth Black Mouse
1. Netfinity 5500 and 5500 M10 include a single 400 W power supply which is sufficient to
operate fully configured systems. If power supply redundancy is desired, optional power
supply P/N 01K7951 is required.
2. Includes a power cord which requires an additional power source. Even though a second
UPS provides a redundant power source, systems management software does not currently
take advantage of its power outage alerts.
3. Stated runtimes and power are for typical configurations (approximately 70% of maximum
capacity). For additional information see Appendix C: UPS Runtime Estimate.
4. Height is 3U. See “Rack and NetBAY” for supported IBM racks.
5. Installation within a rack requires optional Monitor Compartment (P/N 94G7444).
6. Not supported for installation in a 19” rack.
7. Installation within a rack requires optional Netfinity Flat Panel Rack Mount Kit (P/N 37L6857)
and Netfinity Rack Keyboard Tray (P/N 28L4707). A space saver keyboard may coexist within
the same 28L4707 keyboard tray.
8. Used for routing the second internal SCSI RAID channel to an external 0.8 mm VHDCI
connector . Can be used with IBM .8 mm to 68-pin SCSI Adapter (P/N 01K8017) to provide an
external 68-pin high density connector.
40
Description
1. Includes one Netfinity NetBAY3 with skid pads. Optional casters (P/N 10L6913)
are available.
2. Netfinity 5500 and 5500 Mxx rack models are housed in a 19” rack mountable
drawer and require one of the racks listed here.Tower models include a single
NetBAY3 with skid pads. Optional casters (P/N 10L6913) are available. See IBM
Netfinity Rack Cabinet and Options section for IBM rack NetBAY3 with skid
pads.Optional casters (P/N 10L6913) are available. See IBM Netfinity Rack
supported devices.
3. A maximum of three NetBAY3 enclosures (including the standard one) may be
stacked beneath a supported Netfinity tower server. Casters are not included.
See IBM Netfinity NetBAY3 Stackable Enclosure section for supported devices.
4. Tower models include both a mouse and keyboard. Rack models include
neither.
5. Installation within a rack requires optional keyboard tray P/N 28L4707 (stows in
“ready-to-use” position).
6. Installation within a rack requires optional keyboard tray P/N 28L4707. This
keyboard cannot share a keyboard tray with a flat panel display.
7. Advanced TrackPoint IV features are not available on IBM Netfinity systems.
Netfinity 5500 Tape Options
Part
Number
Description
Bays
Supported
SCSI
Interface
(bit)
Form
Factor
Termination 68/50- pin Ext. Tape
Included
Converter
Encl.1
Incl.
01K1282
12/24 GB DDS/3 4-mm Internal Tape Drive
A, B
8
3.5” HH or
5.25” HH
Y2
Y
3510020
00N7991
20/40 GB DDS/4 4-mm Internal Tape Drive
A,B
16 Ultra2 LVD
3.5” HH or
5.25” HH
Y2
N
3510020,
3551001
01K1325
20/40 GB 8-mm Internal SCSI Tape Drive
A, B
16
5.25” HH
N3
N
3551001
35100204
01K1320
20/40 GB DLT Internal SCSI Tape Drive
A/B5
8
5.25” FH
Y2
Y
3503B0X,
3551001
04K0149
35/70 GB DLT Internal SCSI Tape Drive
A/B5
16
5.25” FH
N3
N
3503B0X4,
3551001
00N7990
40/80 GB DLT Internal SCSI Tape Drive
A/B5
16 LVD
5.25” FH
N3
N
3503B0X4,
3551001
32G3918
SCSI-2 16-bit Active Terminator
-
16
External
Y
N
3510020,
3503B0X
3510020
External Half High SCSI Storage Enclosure6
-
8/16
Desktop
N
N
-
3551001
NetMEDIA Storage Expansion Unit EL7
-
16
Rack
Y
N
-
10L7113
NetMEDIA Systems Management Adapter8
-
16
-
N
N
3551001
DLT External SCSI Enclosure9
-
16
Desktop
N
N
-
-
16
Desktop
Y
-
-
External Tape Enclosures
3503B0X
External Tape Libraries10
3502108
DLT Tape Autoloader
3502x14
DLT Tape Library
-
16
Desktop or
Rack
Y
-
-
3503108
DLT8000 Tape Autoloader
-
16 LVD
Desktop
Y
-
-
Y
-
-
Y
-
-
3503x14
DLT8000 Tape Library
-
16 LVD
Desktop or
Rack
3570xxx
Magstar MP 3570 Tape Subsystem
(models B2x and C2x)
-
Diff.
Rack
1. To determine cable requirements, note the tape drive’s SCSI interface, the appropriate SCSI controller from the system configurator section, and the desired enclosure and then refer to
Appendix D: Cables - Storage Units - Controllers.
2. Tape drive is capable of self termination.
3. Termination is provided by the system unit’s standard SCSI cabling.
4. Requires SCSI-2 16-bit Active Terminator (P/N 32G3918).
5. Two Half-High (HH) bays can be combined to support a single Full-High (FH) device.
6. Provides a black desktop 5.25” half-high (HH) tape enclosure. Connector is configurable as 50-pin Centronix or 68-pin high density. Requires either tape drive self termination or SCSI-2
16-bit Active Terminator (P/N 32G3918).
7. Provides a black 3U, 19” rack or NetBAY3 mountable tape enclosure. Provides two full high (FH) or four half high (HH) extended length 5.25” bays. External connector is 0.8-mm VHDCI.
Includes two power supplies and two power cords.
8. Installs in a 3551001. Provides repeater function and LVDS interface allowing longer cable lengths and auto-termination when the 3551001 is powered off.
9. Provides a black desktop DLT tape enclosure with a 68-pin high density external connector. Requires termination by the tape drive or by installation of a SCSI-2 16-bit Active Terminator
(P/N 32G3918).
10. Tape library attributes and prerequisites are located in Appendix B: Tape Library Attributes.
NOTE: SCSI support for tape drives is provided by system unit onboard (standard) controller (no-RAID function) or PCI Fast Wide Ultra SCSI Adapter P/N 02K3454. Additional tape attributes
can be found in Appendix A: Tape Drive Attributes.
Updated 01/01/00
For the latest product & technical information, refer to the Information Sources on pages 1 and 2.
41
IBM NETFINITY 5500
Associated Options
Sample Configurations
Note: The following sample configurations are for illustration only and may not be suitable for any specific customer installation. Contact your IBM Business Partner or IBM Marketing
Representative for assistance with your specific configuration requirements.
High Availability
Part Number
8660-72U
01K8053
01K1320
7852400
01K7951
10L6912
94G6674
65464AN
Description
Quantity
Netfinity 5500 (Pentium III 550/128 MB, Tower & NetBAY3)
Netfinity 9.1 GB Wide Ultra SCSI SCA-2 SL HDD
20/40 GB DLT Internal SCSI Tape Drive
External V.34 Data/Fax Modem
Netfinity 400 W Hot-swap Redundant Power Supply II
Netfinity NetBAY3
APC Smart-UPS 1400RMB1
G54 Color Monitor 15” (13.7” Viewable Image Size), stealth black
1
6
1
1
1
1
2
1
Usage
NOS-mirrored, Data-RAID 5
Remote Management
Enclosure for second UPS
Redundant UPSs
1. Even though a second UPS provides a redundant power source, systems management software does not currently take advantage of its power outage alerts.
This tower server is configured to act as the foundation for business critical applications, applications your business cannot afford to be without. Configured with enough disk drives to mirror
the operating system and provide a standard RAID 5 environment for data, optional hot-swap redundant power, redundant UPSs for power even during a blackout or in the event of a UPS or
power cord failure, this server represents the leading edge in high availability. An internal tape drive is included to back-up that all important asset.... data, and a modem is included to allow
out-of-band (non-LAN) system management utilizing the Netfinity Advanced System Management Processor.
Web Server
Part Number
8660-61U
01K8023
36L9806
footnote 1
01K1320
02K3454
03K9313
10L6912
35202RU
36L9809
03K9310
01K7951
94G6676
65464AN
Description
Netfinity 5500 (Pentium III 500/128 MB, Tower & NetBAY3)
128 MB SDRAM ECC DIMM
Netfinity 9.1 GB 10K-3 Wide Ultra SCSI Hot-Swap SL HDD
High Speed ISDN connection1
20/40 GB DLT Internal SCSI Tape Drive
PCI Fast/wide Ultra SCSI Adapter
Netfinity SCSI Controller Cable
Netfinity NetBAY3
Netfinity EXP15
Netfinity EXP 9.1 GB 10K-3 Wide Ultra SCSI Hot-Swap HDD
Netfinity 2M Ultra2 SCSI Cable
Netfinity 400 W Hot-Swap Redundant Power Supply II
APC Smart-UPS 3000RMB2
G54 Color Monitor 15” (13.7” Viewable Image Size), stealth black
Quantity
Usage
1
3
6
1
1
1
1
1
1
5
1
1
2
1
Total Memory: 512 MB
RAID 5 Data Storage
Connection to Web
Tape Controller
Provides external RAID
Enclosure for EXP15
Provides additional 10 Bays
RAID 5 Data Storage
Attaches EXP15 to 03K9313
Redundant UPSs
-
1. Select from ServerProven options found on the Web at URL www.ibm.com/pc/us/compat. Warranty and service for third party ServerProven products is provided for by the manufacturer,
not IBM.
2. Even though a second UPS provides a redundant power source, systems management software does not currently take advantage of its power outage alerts.
This tower model is configured as the perfect Web presence for a company ready for eBusiness. With enough disk storage to host a large sales catalog, an optional hot-swap power supply
and UPS so that your server is ready when your customers are ready to order, and an ISDN adapter to allow for a speedy connection into the Web infrastructure, on top of all the integrated
high-availability features make this the ideal server for electronic commerce.
42
Two Node High Availability Cluster
Public
ServeRAID-3HB
(37L6086)
CH3
CH2
LAN
Server Node A
10/100 Ethernet (34L1501)
CH1
Integrated10/100 Ethernet
(03K9311)
Netfinity EXP 15
(25’ Ethernet
Crossover Cable1)
Server Node B
CH3
CH2
CH1
Integrated10/100 Ethernet
ServeRAID-3HB
(37L6086)
10/100 Ethernet (34L1501)
Public
LAN
Part Number
Two Node High Availability Cluster
Description
Server Nodes A & B
8660-7SU
33L5112
01K8053
37L6086
34L1501
00N7990
02K3454
7852400
01K7951
94G6676
Netfinity 5500 (Pentium III 550/256 MB, Rack) (8U)
Netfinity 550/512 KB Upgrade with Pentium III Processor
Netfinity 9.1 GB Wide Ultra SCSI SCA-2 SL HDD
Netfinity ServeRAID-3HB Ultra2 SCSI Adapter2
Netfinity 10/100 Ethernet PCI Adapter 21
40/80 GB DLT Internal SCSI Tape Drive
PCI Fast/Wide Ultra SCSI Adapter
External V.34 Data/Fax Modem
Netfinity 400 W Hot-Swap Redundant Power Supply II
APC Smart-UPS 3000RMB (3U)
35202RU
01K7959
03K9311
Netfinity EXP152 (3U)
Netfinity EXP10 9.1GB Wide Ultra SCSI SCA-2 HDD2
Netfinity 4.2M Ultra2 SCSI Cable2
9513AG1
28L3644
T55A Flat Panel Color Monitor (15” Viewable Image Size), stealth black
Space Saver II Keyboard
9306900
28L4707
37L6857
28L0542
94G6667
94G7447
94G6669
94G6670
9306-900 Netfinity Rack
Netfinity Rack Keyboard Tray
Netfinity Flat Panel Monitor Rack-Mount Kit (3U)
Netfinity Console Server Selector Switch (4-port)
Power Cable-Type A14 3
12ft. Console Cable Set
Side Panel Kit
Blank Filler Kit
Quantity
Usage
2
2
4
2
2
1
1
2
2
2
Dual SMP Processing
NOS on mirrored HDD’s
3 channels for EXP15’s
Private Interconnect
1
5
2
RAID 5 Shared Storage
Attach EXP15 to Servers
1
1
Mounts in keyboard tray
-
1
1
1
1
3
2
1
2
Mounts in keyboard tray (3U)
-
IBM NETFINITY 5500
1.Customer supplied Ethernet Crossover Cable may vary in length up to a maximum of 25’ (7.6 m).
Tape Drive Controller
Remote Management
-
Storage Expansion Unit
Shared (or single occurrence) Resources
Industry Standard 19” Rack, EIA-310D, Min. depth of 28”
1. Requires customer supplied Ethernet Crossover Cable which may vary in length up to a maximum of 25’ (7.6 m).
2. By replicating these items, up to a total quantity of four ServeRAID-3HB Adapters (plus options) and eleven EXP15s can provide over 2 Terabytes of storage. Additional power
and Rack space will be required.
3. Cable length requirements are dependant on component placement within the rack or rack suite. To determine specific configuration requirements use the Netfinity Rack
Configurator which is downloadable from Web site www.ibm.com/pc/us/netfinity/tech_library.html “Configuration Tools”.
Clustering is a group of interconnected computers used as a single, unified computing resource. Clustering Netfinity servers, like the IBM Netfinity 5500, provides a
high availability solution to keep you in touch with the key applications you need to run your business.
This sample configuration consists of paired IBM Netfinity 5500 cluster nodes equipped with two-way SMP capability and redundant power supplies. Microsoft
Cluster Service (MSCS) has been validated on IBM Netfinity 5500 servers, using the IBM ServeRAID-3HB with the EXP15 Storage Expansion Unit. MSCS allows two
configured servers, referred to as nodes, to be connected together to form a cluster. Providing system redundancy means that a complete server can fail and client
access to server resources is largely unaffected. MSCS extends this theme by also allowing for software failures at an application level as well as an operating
system level. If the operating system fails, all applications and services can be restarted on another server, and if just one application fails, it can be managed by
MSCS individually. An additional independent network connection is used to perform monitoring within the cluster. One or more disk subsystems are attached to
both nodes. In the above example, a Netfinity EXP15 was selected and the IBM ServeRAID-3HB Ultra2 SCSI Adapters provide the I/O control. Netfinity
ServeRAID-3HB handles the “SCSI heartbeat” connection without the need for a dedicated SCSI connection and logically attaches the quorum disk, which allows
arbitration when a failure occurs. Additional information on IBM Netfinity and IBM PC Server Clustering Solutions may be found on the World Wide Web by accessing
URL www.ibm.com/pc/us/netfinity/clustering.html.
Updated 01/01/00
For the latest product & technical information, refer to the Information Sources on pages 1 and 2.
43
IBM Netfinity 5500 M10 Configurator
)
VD
, L a il) x )
D
I
)
2
a
A
Av
c
ar
ax D,
ro
M)
, R tal/ td/M
nd
/M
IM
t P s)
ta
tra (To e (S
td
HD
l
D
n
S
S
,
(
U
(
e
s
)
l,
s
ys riv
y
l,
m bp
=R
ot
Hz or B)
na
)
tit
Ba k D
ua
g e (M
Sl
(R
(M ss
tio
a il
an
r,
(D dia
il)
na net
x)
is
p
d oce . (K
u
e
r
a
a
D
r
e
O
va
/Av
e Me
Q
w
)
(
e
l
l
M
e
e
r
M
l
A
d
r
o
/
h
/
y
E
a
h
r
l
P
r o le
cy
td
or
Sp of P ac
pl
be
ta (Tot
em E t
(ID
Ha
p(
nt
b
ct
C
(S
m
an
up
or
st d
r
To
Fa
Co ova rnal
wa
ry
nd
ss be CC
OM s: ( ots:
Nu
Sy oar
rS
I
S
o
u
e
.
R
t
e
m
E
b
l
S
m
t
e
d
m
y
r
v
r
m
t
w
S
oc N u L2
Pa
Fo
SC
CD
Ba
Ad On
Re
Re In
Ho
Po
Me
Pr
ns
Fa
)
ax
d/M
t
S
866151Y
5506
1/2
512
256 MB (R)/2 GB
86615RY1
5506
1/2
512
256 MB (R)/2 GB
)
d)
r
so
es
1/2
P, S,H,F
S-Fans,
O-Power
Y
10/100
D,R
4/2
0/109 GB4
32X-14X5
10/8
7/7
Rack (8U) 1/2
P, S,H,F
S-Fans,
O-Power
Y
10/100
D,R
4/2
0/109 GB
32X-14X5
10/8
7/7
Tower3
1. Housed in a 19” Rack mountable drawer and ships standard without a keyboard or mouse. See “Rack and NetBAY” under “Netfinity 5500 M10 Power, Monitor &
Accessories” for supported IBM racks.
2. All memory is 100 MHz ECC SDRAM Registered DIMMs (RDIMMs) and is compatible with Netfinity Four-Way Processor Upgrade Kit (P/N 28L1014) which increases the
maximum memory to 4 GB.
3. Tower models come equipped with a single NetBAY3, 3U stackable enclosure. Up to a maximum of three are supported.
4. With a single Netfinity EXP15 installed in the standard NetBAY3, the maximum internal storage increases by 364 MB.
5. Variable read rate. Actual playback speed will vary and is often less than the maximum possible.
6. Intel Pentium III Xeon processor.
Netfinity 5500 M10 Processor Upgrades
Part
Number
Processor Upgrades with 512 KB or 1 MB Cache
SMP
Support1
Processor Speed/
Cache Upgrade2
Upgrade 28L1014
Compatible
01K7264
Netfinity 5500 400 MHz/512 KB Upgrade with Pentium II Xeon Processor
All 1xY
-
-
10L5894
Netfinity 5500 400 MHz/1 MB Upgrade with Pentium II Xeon Processor
All 2xY
All 1xY
-
10L5901
Netfinity 5500 450 MHz/512 KB Upgrade with Pentium II Xeon Processor
All 3xY
All 1...2xY
X
10L5902
Netfinity 5500 450 MHz/1 MB Upgrade with Pentium II Xeon Processor
All 4xY
All 1...3xY
X
33L5107
Netfinity 550 MHz/512 KB Upgrade with Pentium III Xeon Processor
All 5xY
All 1...4xY
X
28L1014
Netfinity Four-Way Processor Upgrade Kit3, 4
-
All
-
1. One additional processor may be installed, providing a maximum of two. All processors must be identical in type, speed and cache size.
2. Requires removal of the standard processor. A maximum of two processors may be installed. All processors must be identical in type, speed and cache size. Upgrades may require a
BIOS update. To obtain the latest Flash BIOS, access www.ibm.com/pc/support and enter machine “Type-Model” in Quick Path. Select “Downloadable files” and then “BIOS”.
3. Provides required components for upgrading an IBM Netfinity 5500 or 5500 M10 to a 4-way SMP capable system. Installation of P/N 28L1014 prevents the use of PCI slot 6 and shortens
slot 5 to Half Length. Installation must be performed by an IBM trained servicer or IBM Customer Engineer and is included in the purchase price. Key components include: memory card
(4 GB capacity), processor card assembly, power backplane, 500W power supply, assorted cables, led card, and chassis hardware. Components that are NOT included and must be
ordered separately: processors, additional memory and 500 W redundant power supply. Optional processors supported by the four-way upgrade kit are indicated by an “X” in the column
titled “Upgrade 28L1014 Compatible”.
4. Processors from 8661-3xY and 8661-4xY are supported for use with upgrade kit P/N 28L1014. All others must be replaced when the upgrade kit is installed. Refer to Netfinity 5500 M20
configurator for option compatibility with any 5500 or 5500 M10 containing upgrade P/N 28L1014. A maximum of four processors may be installed. All processors must be identical in type,
speed and cache size. Upgrades may require a BIOS update. To obtain the latest Flash BIOS, access www.ibm.com/pc/support and enter machine “Type-Model” in Quick Path. Select
“Downloadable files” and then “BIOS”.
44
Netfinity 5500 M10 Memory
Total
Memory
RDIMM Slot 1 - J4
RDIMM Slot 2 - J3
Models 8661-1...4xY
128 MB
128 MB RDIMM Standard
256 MB
1 x 01K7262
Models 8661-5xY
256 MB RDIMM Standard
RDIMM Slot 3 - J2
384 MB
1 x 01K8043
1 x 01K7262
RDIMM Slot 4 - J1
512 MB
1 x 01K7262, 1 x 01K8043
1 x 01K8043
640 MB
1 x 01K7263 or 2 x 01K80432
1 x 01K7262, 1 x 01K8043
768 MB
(1 x 01K7262, 1 x 01K7263) or
(1 x 01K7262, 2 x 01K8043)2
1 x 01K7263 or 2 x 01K80432
896 MB
(1 x 01K8043, 1 x 01K7263) or
3 x 01K80432
(1 x 01K7262, 1 x 01K7263) or (1 x 01K7262,
2 x 01K8043)2
Part
Number
Standard RDIMM
Memory Description
01K7262
Netfinity 128 MB SDRAM ECC RDIMM1
1024 MB
2 x 01K7263 or 4 x 01K80431,2
(1 x 01K8043, 1 x 01K7263) or 3 x 01K80432
01K8043
Netfinity 256 MB SDRAM ECC RDIMM1
1280 MB
1 x 01K7262 or 2 x 01K7263
2 x 01K7263 or (2 x 01K8043, 1 x 01K7263)2
01K7263
RDIMM1
1408 MB
1 x 01K8043, 2 x 01K7263
1 x 01K7262, 2 x 01K7263
1664 MB
3 x 01K7263
Netfinity 512 MB SDRAM ECC
1. RDIMMs must be installed in sequence beginning with Slot 4 (J1)
and ordered from largest to smallest.
-
1792 MB
-
2048 MB (max) 4 x 01K72631
3 x 01K7263
4 x 01K72631
This table does not represent all possible memory configurations.
1. Replace standard RDIMM.
2. Memory modules may vary in price per MB. Selection of smaller RDIMMs may provide a more cost-effective
alternative to using the largest RDIMMs and should be considered when anticipated future memory is 1 GB or less.
Netfinity 5500 M10 Hard Disk Drive (HDD) Storage
Total Int.
Storage1
7200 RPM Hard Disk Drives (HDDs)
0 GB
Standard on Base Models
18.2 GB
9.1 GB
1 x 01K8053
18.2GB
2 x 01K8053 or 1 x 02K0440
-
27.2 GB
3 x 01K8053
-
36.4 GB
4 x 01K8053 or 2 x 02K0440 or
45.5 GB
5 x 01K8053
54.6GB
72.8 GB
-
6 x 01K8053 or 3 x 02K0440
-
91 GB
-
109 GB (max)
-
4 X 02K0440 or
5 X 02K0440
6 X 02K0440 or
36.4 GB
10,000 RPM Hard Disk Drives (HDDs)
9.1 GB
18.2 GB
36.4 GB
Standard on Base Models
-
1 x 36L9806
2 x 36L9806 or
-
3 x 36L9806
1 X 02K0441 4 x 36L9806 or
-
5 x 36L9806
-
6 x 36L9806 or
2 X 02K0441
-
1 x 36L9807
2 x 36L9807or
3 x 36L9807
4 x 36L9807 or
-
-
5 x 36L9807
3 X 02K0441
-
6 x 36L9807 or
-
IBM NETFINITY 5500 M10
9.1 GB
1 x 36L9808
2 x 36L9808
3 x 36L9808
This table does not represent all possible hard drive configurations.
1. Total internal storage listed is within + 0.2 GB unless otherwise noted.
Updated 01/01/00
For the latest product & technical information, refer to the Information Sources on pages 1 and 2.
45
Bay
Form
Factor
Height
Front
Access
Usage
Part
Number
Description
RPM
Height
Bays
Max.
Supported Qty.
Internal Hard Disk Drives (HDD)
-
3.5”
SL
Yes
Diskette
-
5.25”
HH
Yes
IDE CDROM
01K8053
Netfinity 9.1 GB Wide Ultra SCSI
SCA-2 SL HDD
7200
SL
1...6
6
A
5.25”
HH1
Yes
Open
02K0440
Netfinity 18.2 GB Wide Ultra
SCSI Hot-Swap SL HDD
7200
SL
1...6
6
B
5.25”
HH1
Yes
Open
02K0441
Netfinity 36.4 GB Wide Ultra
SCSI Hot-Swap HDD
7200
HH1
1/2, 3/4, 5/6
3
10,000
SL
1...6
6
10,000
SL
1...6
6
10,000
HH1
1/2, 3/4, 5/6
3
2
Yes
Open
36L9806
Netfinity 9.1 GB 10K-3 Wide
Ultra SCSI Hot-Swap SL HDD
Yes
Open
36L9807
Netfinity 18.2 GB 10K-3 Wide
Ultra SCSI Hot-Swap SL HDD
36L9808
Netfinity 36.4 GB 10K-3 Wide
Ultra SCSI Hot-Swap HDD
1...6
HS
SL
NB33
19” Rack
3U
1. Two half-high (HH) bays can be combined to support a single full-high
device.
2. Two slim-line (SL) bays can be combined to support a single half-high
device.
3. One NetBAY3 is included with tower models and a total of three are
supported. See IBM Netfinity NetBAY3 Stackable Enclosure section for
supported devices.
Removable
Media(RM)
Diskette
CD-ROM
Bay A
Bay B
Hot Swap
(HS)
External Storage Expansion
Units2
Form Factor
35202RU
Netfinity EXP15 Storage
Expansion Unit
Rack (3U)
35301RU
Netfinity EXP200 Storage
Expansion Unit
Rack (3U
37L5857
Netfinity EXP200 Rack-toTower Conversion Kit
Tower
1. Two slim-line (SL) bays can be combined to support a single half-high (HH) device.
2. Supported by the onboard external SCSI port (requires Netfinity SCSI Controller Cable P/N 03K9313). Select
the onboard or optional SCSI controller then refer to Appendix D: Cables-Storage Units-Controllers to confirm
the controller supports the desired External Storage Expansion Unit and to select a supported cable. For HDD
or other expansion unit options, see the specific expansion unit section.
Bay 1
Bay 2
Bay 3
Bay 4
Bay 5
Bay 6
Netfinity NetBAY3 (NB3)
(Tower Models Only)
Internal SCSI Cabling
Netfinity 5500 and 5500 M10 systems contain a backplane supporting six hot-swap drive bays. The backplane is connected to one of the two connectors of the
integrated dual-channel ServeRAID controller through a 16-bit SCSI cable. A two-drop 16-bit SCSI cable, with an integrated terminator, is included with the server to
support up to two internal removable media devices connected to the second RAID connector or a supported SCSI adapter. Optional Netfinity SCSI Controller
Cable (P/N 03K9313) is a 16-bit cable that can be attached to the second RAID connector and routed to the rear panel cutout providing an external 16-bit VHDCI 0.8
mm connector. If internal removable devices are required in addition to external RAID device attachment, a supported SCSI adapter must be installed using the
standard two-drop SCSI cable for device/adapter connection. If connecting narrow devices to this cable, additional 68-pin to 50-pin converters (P/N 32G3925) must
be ordered. Some narrow devices include a converter in their ship group.
46
Netfinity 5500 M10 I/O Options
Part
Number
Description
Adapter
PCI
Slots
HotLength Support Supported1 Plug2
Storage Controllers3
01K7364
Netfinity ServeRAID-3L Ultra2 SCSI Adapter4, 5
Full
32-bit
1...6
X
37L6086
Netfinity ServeRAID-3HB Ultra2 SCSI Adapter6
Full
32/64-bit
1...6
X
02K3454
PCI Fast/Wide Ultra SCSI Adapter
Half
32-bit
1...6
-
01K7297
Netfinity Fibre Channel PCI Adapter7
Half
32/64-bit
1...6
-
09L2123
Advanced SerialRAID/X Adapter
Full
32-bit
1...68
-
Networking
9
Half
32-bit
1...6
X
Netfinity 10/100 Fault Tolerant Adapter
Half
32-bit
1...6
X
Netfinity Gigabit Ethernet SX Adapter
Half
32/64-bit
1...6
X
34L0301
34L0501
Token-Ring 100/16/4 High-Speed PCI Adapter
Half
32-bit
1...6
-
34L0601
Token-Ring 16/4 PCI Adapter 2
Half
32-bit
1...6
-
33L4618
PCI V.90 56 Data/Fax Modem10
Half
32-bit
1...6
-
37L1414
Serial I/O SST8P DB Adapter11
Half
32-bit
1...611
-
37L1415
Serial I/O SST16P RJ Adapter11
Half
32-bit
1...611
-
37L1423
Serial I/O SST16P DB Adapter11
Half
32-bit
1...611
-
37L1416
Serial I/O SST128P Expandable Adapter11
Half
32-bit
1...611
-
Systems Management12
01K7209
Netfinity Advanced System Management PCI Adapter13
Full
32-bit
1...614
-
03K9309
Netfinity Advanced System Management Interconnect Cable Kit15
-
-
-
-
36L9654
Netfinity Advanced System Management Token-Ring
Connection16
-
-
-
-
9086001
Netfinity ESCON Adapter17
Full
32-bit
1...618
-
Host Attach
ISA, Full Length
Communications
Slot 1- PCI, Hot- Plug, 32-bit, Full Length
Slot 2- PCI, Hot- Plug, 32-bit, Full Length
Slot 3- PCI, Hot- Plug, 32-bit, Full Length
Slot 4- PCI, Hot- Plug, 32-bit, Full Length
Token Ring
1. PCI Slots 1, 2, 3 and 4 support Hot Plug devices.
2. Hot Plug capable using IBM’s Active PCI technology.. For Network Operating System support access URL www.ibm.com/pc/us/compat.
3. Netfinity 5500 and 5500 Mxx have a dual-channel ServeRAID II Wide Ultra SCSI controller.
4. All ServeRAID-3x adapters can be upgraded with the same enhanced software utilities and firmware included with ServeRAID-3HB. The download is available for no charge from
www.ibm.com/pc/support. Select “Server” in Brand pulldown, “ServeRAID” in Family pulldown and then “Downloadable files”. The upgrade shouold be considered for installations with
firmware less than Version 3.5.
5. Netfinity ServeRAID-3L Ultra2 SCSI Adapter (P/N 01K7364) provides either one internal or one external (0.8 mm VHDCI) LVDS SC SI channel.
6. Netfinity ServeRAID-3HB Ultra2 SCSI Adapter (P/N 37L6086) provides one internal and two external (0.8 mm VHDCI) LVDS SCSI ch annels. The internal channel can be configured for
external usage (0.8 mm VHDCI) providing a total of three external LVDS SCSI channels. Includes 32 MB of mirrored battery-backup cache, which helps protect against data loss in write-back
cache mode in the event of a power outage or adapter maintenance.
7. See Netfinity Fibre Channel Solutions section for additional configuration information.
8. A maximum quantity of four is supported.
9. Netfinity 5500 and 5500 Mxx have an integrated 10/100 PCI Ethernet Controller.
10. Due to homologation variances, modem availability may differ by country.
11. See Appendix E for details on Serial I/O options and configuration limitations. A maximum of four Serial I/O adapters (any combination of P/N 37L1414, 37L1415, 37L1416, 37L1423) may be
installed.
12. The Netfinity Advanced System Management Processor and Interconnect Bus integrated into Netfinity 5500 (8660-5...6xU) and 5500 Mxx works with Netfinity Manager to provide
significant system management function. When used with optional Netfinity Advanced System Management PCI Adapter (P/N 01K7209) and Netfinity Advanced System Management
Interconnect Cable Kit (P/N 03K9309) additional management and control of up to12 service processors from a remote console thro ugh a single modem or LAN connection is possible.
Systems management options P/N 01K7209, 03K9309, and 36L9654 are NOT supported by Netfinity 5500 models 8660-1...4xU.
13. Includes PCI adapter, Netfinity Advanced Systems Management Interconnect Cable Kit components and 56-watt AC adapter, which requires a separate power source. Provides an
integrated 10/100 Ethernet port and a PCMCIA slot to support optional Netfinity Advanced System Management Token-Ring Connection (P/N 36L9654). NOT supported by Netfinity 5500
models 8660-1...4xU.
14. A maximum quantity of one is supported.
15. Required for all Netfinity Servers containing a standard Advanced System Management Processor that are to be interconnecte d for system management support through a LAN or
modem connection (Netfinity 5500 models 8660 1...4xU are not supported). Optional Netfinity Advanced System Management PCI Adapter (P/N 01K7209) includes the contents of this
option. Up to 12 service processors may be interconnected (including standard and optional processors) with an aggregate conne ction length of no more than 91.4 meters (300 ft.). A
customer-supplied Ethernet cable is required for each interconnection.
16. Contains an IBM Turbo 16/4 Token-Ring PCI Card, which installs in the PCMCIA card slot of Netfinity Advanced System Managem ent PCI Adapter (P/N 01K7209), and a PC Card to 9-pin
D-Shell cable which is routed to a rear chassis cut-out. The Netfinity Advanced System Management PCI Adapter’s integrated Eth ernet port and Netfinity Advanced System Management
Token-Ring Connection cannot be connected or used together.
17. Provides an ESCON MIC and DB9 Serial Port. Cables are not included but are available through S/390 channels. Contact your IBM representative for additional information.
18. A maximum of two 9086001 adapters (installed in non-adjacent slots) are supported in a single Netfinity server.
Updated 01/01/00
For the latest product & technical information, refer to the Information Sources on pages 1 and 2.
47
IBM NETFINITY 5500 M10
Netfinity 10/100 Ethernet PCI Adapter 2
08L3341
Slot 5- PCI, 32-bit, Primary Bus, Full Length
Slot 6- PCI, 32-bit Primary Bus, Full Length
Ethernet
34L1501
Netfinity 5500 M10 Power, Monitor & Accessories
Part
Number
Description
Part
Number
Description
Power1
01K7951
Conversion Kits
Netfinity 400 W Hot-Swap Redundant Power
Supply II2
Uninterruptible Power Supply
94G3136
(UPS)3
Netfinity 5500 Rack-to-Tower Kit1
01K8020
Netfinity 5500 Tower-to-Rack Kit
Rack and NetBAY2
APC Smart-UPS 1400 (26 min. runtime at 375 Watts)
94G6674
APC Smart-UPS 1400 RMB (21 min. runtime at 375
Watts)4
930842P
Netfinity Enterprise Rack
94G6676
APC Smart-UPS 3000 RMB (55 min. runtime at 375 Watts)4
930842X
Netfinity Enterprise Expansion Cabinet
9306900
Netfinity Rack
65464AN
G54 Color Monitor 15” (13.7” Viewable Image Size), stealth
black5
9306200
Netfinity NetBAY22
65474AN
G74 Color Monitor 17” (15.9” Viewable Image Size), stealth
black5
10L6912
Netfinity NetBAY33
65494AN
G96 Color Monitor 19” (17.9” Viewable Image Size), stealth
black6
10L6913
Netfinity Caster Set
9513AG1
T55A Flat Panel Color Monitor (15.0” Viewable Image Size),
stealth black7
Monitors
Cables
03K9313
Netfinity SCSI Controller Cable (0.8
32G3925
SCSI 68-pin to 50-pin Converter
Keyboard and Mouse4
28L3644
mm)8
1. Netfinity 5500 and 5500 M10 include a single 400W power supply which is sufficient
to operate fully configured systems. If power supply redundancy is desired, optional
power supply P/N 01K7951 is required.
2. Includes a power cord which requires an additional power source. Even though a
second UPS provides a redundant power source, systems management software does
not currently take advantage of its power outage alerts.
3. Stated runtimes and power are for typical configurations (approximately 70% of
maximum capacity). For additional information see Appendix C: UPS Runtime Estimate.
4. Height is 3U. See “Rack and NetBAY” for supported IBM racks.
5. Installation within a rack requires optional Monitor Compartment (P/N 94G7444).
6. Not supported for installation in a 19” rack.
7. Installation within a rack requires optional Netfinity Flat Panel Monitor Rack Mount Kit
(P/N 37L6857) and Netfinity Rack Keyboard Tray (P/N 28L4707). A space saver
keyboard may coexist within the same 28L4707 keyboard tray.
8. Used for routing the second internal SCSI RAID channel to an external .8 mm VHDCI
connector. Can be used with IBM .8 mm to 68-pin SCSI Adapter (P/N 01K8017) to
provide an external 68-pin high density connector.
48
01K8021
Space Saver II Keyboard5,7
01K1260
TrackPoint IV 104-Key Black Keyboard6,7
28L3621
Preferred Keyboard (stealth black)6
28L3673
Sleek 2-Button Stealth Black Mouse
1. Includes one Netfinity NetBAY3 with skid pads. Optional casters (P/N 10L6913) are available.
2. Netfinity 5500 and 5500 Mxx rack models are housed in a 19” rack mountable drawer and
require one of the racks listed here.Tower models include a single NetBAY3 with skid pads.
Optional casters (P/N 10L6913) are available. See IBM Netfinity Rack Cabinet and Options
section for IBM rack NetBAY3 with skid pads.Optional casters (P/N 10L6913) are available. See
IBM Netfinity Rack supported devices.
3. A maximum of three NetBAY3 enclosures (including the standard one) may be stacked
beneath a supported Netfinity tower server. Casters are not included. See IBM Netfinity
NetBAY3 Stackable Enclosure section for supported devices.
4. Tower models include both a mouse and keyboard. Rack models include neither.
5. Installation within a rack requires optional keyboard tray P/N28L4707 (stows in “ready-to-use”
position).
6. Installation within a rack requires optional keyboard tray P/N 28L4707. This keyboard cannot
share a keyboard tray with a flat panel display.
7. Advanced TrackPoint IV features are not available on IBM Netfinity systems.
Netfinity 5500 M10 Tape Options
Part
Number
Description
Bays
Supported
SCSI
Interface
(bit)
Form
Factor
Termination 68/50- pin Ext. Tape
Included
Converter
Encl.1
Incl.
01K1282
12/24 GB DDS/3 4-mm Internal Tape Drive
A, B
8
3.5” HH or
5.25” HH
Y2
Y
3510020
00N7991
20/40 GB DDS/4 4-mm Internal Tape Drive
A, B
16 Ultra2 LVD
3.5” HH or
5.25” HH
Y2
N
3510020
3551001
01K1325
20/40 GB 8-mm Internal SCSI Tape Drive
A, B
16
5.25” HH
N3
N
35100204
3551001
01K1320
20/40 GB DLT Internal SCSI Tape Drive
A/B5
8
5.25” FH
Y2
Y
3503B0X,
3551001
04K0149
35/70 GB DLT Internal SCSI Tape Drive
A/B5
16
5.25” FH
N3
N
3503B0X4,
3551001
00N7990
40/80 GB DLT Internal SCSI Tape Drive
A/B5
16 LVD
5.25” FH
N3
N
3503B0X4,
3551001
32G3918
SCSI-2 16-bit Active Terminator
-
16
External
Y
N
3510020,
3503B0X
3510020
External Half High SCSI Storage Enclosure6
-
8/16
Desktop
N
N
-
3551001
NetMEDIA Storage Expansion Unit EL7
-
16
Rack
Y
N
-
10L7113
NetMEDIA Systems Management Adapter8
-
16
-
N
N
3551001
DLT External SCSI Enclosure9
-
16
Desktop
N
N
-
-
16
Desktop
Y
-
-
Associated Options
External Tape Enclosures
3503B0X
3502108
DLT Tape Autoloader
3502x14
DLT Tape Library
-
16
Desktop or
Rack
Y
-
-
3503108
DLT8000 Tape Autoloader
-
16 LVD
Desktop
Y
-
-
Y
-
-
Y
-
-
3503x14
DLT8000 Tape Library
-
16 LVD
Desktop or
Rack
3570xxx
Magstar MP 3570 Tape Subsystem
(models B2x and C2x)
-
Diff.
Rack
1. To determine cable requirements, note the tape drive’s SCSI interface, the appropriate SCSI controller from the system configurator section, and the desired enclosure and then refer to
Appendix D: Cables - Storage Units - Controllers.
2. Tape drive is capable of self termination.
3. Termination is provided by the system unit’s standard SCSI cabling.
4. Requires SCSI-2 16-bit Active Terminator (P/N 32G3918).
5. Two Half-High (HH) bays can be combined to support a single Full-High (FH) device.
6. Provides a black desktop 5.25” half-high (HH) tape enclosure. Connector is configurable as 50-pin Centronix or 68-pin high density. Requires either tape drive self termination or SCSI-2
16-bit Active Terminator (P/N 32G3918).
7. Provides a black 3U, 19” rack or NetBAY3 mountable tape enclosure. Provides two full high (FH) or four half high (HH) extended length 5.25” bays. External connector is 0.8-mm VHDCI.
Includes two power supplies and two power cords.
8. Installs in a 3551001. Provides repeater function and LVDS interface allowing longer cable lengths and auto-termination when the 3551001 is powered off.
9. Provides a black desktop DLT tape enclosure with a 68-pin high density external connector. Requires termination by the tape drive or by the tape drive or by installation of a SCSI-2 16-bit
Active Terminator (P/N 32G3918).
10. Tape library attributes and prerequisites are located in Appendix B: Tape Library Attributes.
NOTE: SCSI support for tape drives is provided by system unit onboard (standard) controller (no-RAID function) or PCI Fast Wide Ultra SCSI Adapter P/N 02K3454. Additional tape attributes
can be found in Appendix A: Tape Drive Attributes.
Sample Configurations
Note: The following sample configurations are for illustration only and may not be suitable for any specific customer installation. Contact your IBM Business Partner
or IBM Marketing Representative for assistance with your specific configuration requirements.
High Availability
Part Number
8661-51Y
01K8053
01K1320
7852400
01K7951
10L6912
94G6674
65464AN
Description
Netfinity 5500 M10 (Pentium III Xeon 550/256 MB/0 GB, Tower & NetBAY3)
Netfinity 9.1 GB Wide Ultra SCSI SCA-2 SL HDD
20/40 GB DLT Internal SCSI Tape Drive
External V.34 Data/Fax Modem
Netfinity 400W Hot-Swap Redundant Power Supply II
Netfinity NetBAY3
APC Smart-UPS 1400 RMB1
G54 Color Monitor 15” (13.7” Viewable Image Size), stealth black
Quantity
Usage
1
6
1
1
1
1
2
1
NOS-mirrored, Data-RAID 5
Remote Management
Enclosure for second UPS
Redundant UPS
-
1. Even though a second UPS provides a redundant power source, systems management software does not currently take advantage of its power outage alerts.
Updated 01/01/00
For the latest product & technical information, refer to the Information Sources on pages 1 and 2.
49
IBM NETFINITY 5500 M10
External Tape Libraries10
This tower server is configured to act as the foundation for business critical applications, applications your business cannot afford to be without. Configured with enough disk drives to mirror
the operating system and provide a standard RAID 5 environment for data, optional hot-swap redundant power and redundant UPSs for power even during a blackout or in the event of a UPS
or power cord failure, this server represents the leading edge in high availability. An internal tape drive is included to back up that all important asset..... data, and a modem is included to allow
out-of-band (non-LAN) system management utilizing the Netfinity Advanced System Management Processor.
Web Server
Part Number
8661-51Y
01K7262
01K8043
36L9806
footnote 1
01K1320
02K3454
03K9313
10L6912
35202RU
36L9809
03K9310
01K7951
94G6676
65464AN
Description
Netfinity 5500 M10 (Pentium III 550/256 MB/0 GB, Tower & NetBAY3)
Netfinity 128 MB SDRAM ECC RDIMM
Netfinity 256 MB SDRAM ECC RDIMM
Netfinity 9.1 GB 10K-3 Wide Ultra SCSI Hot-Swap SL HDD
High Speed ISDN Connection1
20/40 GB DLT Internal SCSI Tape Drive
PCI Fast/Wide Ultra SCSI Adapter
Netfinity SCSI Controller Cable
Netfinity NetBAY3
Netfinity EXP15
Netfinity EXP 9.1 GB 10K-3 Wide Ultra SCSI Hot-Swap HDD
Netfinity 2 M Ultra2 SCSI Cable
Netfintiy 400W Hot-Swap Redundant Power Supply II
APC Smart-UPS 3000 RMB2
G54 Color Monitor 15” (13.7” Viewable Image Size), stealth black
Quantity
Usage
1
1
1
6
1
1
1
1
1
1
5
1
1
2
1
Total Memory: 640 MB
RAID 5 Data Storage
Connection to Web
Tape Controller
Provides external RAID
Enclosure for EXP15
Provides additional 10 Bays
RAID 5 Data Storage
Attaches EXP15 to 03K9313
Redundant UPSs
-
1. Select from ServerProven options found on the Web at URL www.ibm.com/pc/us/compat. Warranty and service for third party ServerProven products is provided for by the manufacturer,
not IBM.
2. Even though a second UPS provides a redundant power source, systems management software does not currently take advantage of its power outage alerts.
This tower model is configured as the perfect Web presence for a company ready for eBusiness. With enough disk storage to host a large sales catalog, an optional hot-swap power supply
and UPS so that your server is ready when your customers are ready to order, and an ISDN adapter to allow for a speedy connection into the Web infrastructure, on top of all the integrated
high-availability features make this the ideal server for electronic commerce.
50
Two Node
Node High
High Availability
Availability Cluster
Cluster
Two
Public
Public
LAN
LAN
Server Node
Node A
A
Server
ServeRAID-3HB
ServeRAID-3H
(01K7207)
(37L6086)
CH2
CH1
CH2
CH1
10/100 Ethernet
Ethernet (34L0901)
(34L1501)
10/100
CH3
CH3
SCSI
Quorum Link
Integrated10/100 Ethernet
Ethernet
Integrated10/100
(03K9311)
(03K9311)
(25’ Ethernet
Ethernet
(25’
Crossover Cable
Cable11))
Crossover
Netfinity EXP
EXP 15
15
Netfinity
Server Node
Node B
B
Server
CH1
CH3 CH2
CH3 CH2
CH1
(37L6086)
ServeRAID-3HB
ServeRAID-3H
(01K7207)
Integrated10/100 Ethernet
Ethernet
Integrated10/100
10/100 Ethernet
Ethernet (34L0901)
(34L1501)
10/100
Public
Public
LAN
LAN
1.Customer supplied
supplied Ethernet
Ethernet Crossover
Crossover Cable
Cable may
may vary
vary in
in length
length up
up to
to aa maximum
maximum of
of 25’
25’ (7
(7.6
.6 m).
m).
1.Customer
Two Node High Availability Cluster
Part Number
Description
Quantity
Usage
Server Nodes A & B
8661-5RY
Netfinity 5500 M10 (Pentium III Xeon 550/256MB Rack) (8U)
2
-
33L5107
Netfinity 550 MHz/512 KB Upgrade with Pentium III Xeon Processor
2
Dual SMP Processing
01K8053
Netfinity 9.1 GB Wide Ultra SCSI SCA-2 SL HDD
4
NOS on mirrored HDDs
37L6086
Netfinity ServeRAID-3HB Ultra2 SCSI Adapter2
2
Three channels for EXP15s
34L1501
Netfinity 10/100 Ethernet PCI Adapter 21
2
Private Interconnect
00N7990
40/80 GB DLT Internal SCSI Tape Drive
1
02K3454
PCI Fast/Wide Ultra SCSI Adapter
1
Tape Drive Controller
7852400
External V.34 Data/Fax Modem
2
Remote Management
01K7951
Netfinity 400 W Hot-Swap Redundant Power Supply II
2
-
94G6676
APC Smart-UPS 3000RMB (3U)
2
-
35202RU
Netfinity EXP152 (3U)
1
-
01K7959
Netfinity EXP10 9.1 GB Wide Ultra SCSI SCA-2 HDD2
5
RAID 5 Shared Storage
03K9311
Netfinity 4.2 M Ultra2 SCSI Cable2
2
Attach EXP15 to Servers
IBM NETFINITY 5500 M10
Storage Expansion Unit
Shared (or single occurrence) Resources
9513AG1
T55A Flat Panel Color Monitor (15.0” Viewable Image Size), stealth black
1
Mounts in keyboard tray
28L3644
Space Saver II Keyboard
1
-
Industry Standard 19” Rack, EIA-310D, Min. depth of 28”
9306900
9306-900 Netfinity Rack
1
-
28L4707
Netfinity Rack Keyboard Tray
1
Mounts in keyboard tray
37L6857
Netfinity Flat Panel Monitor Rack-Mount Kit (3U)
1
28L0542
Netfinity Console Server Selector Switch (4-port)
1
-
94G6667
Power Cable-Type A143
3
-
94G7447
12ft. Console Cable Set
2
-
94G6669
Side Panel Kit
1
-
94G6670
Blank Filler Kit
2
-
1. Requires customer supplied Ethernet Crossover Cable which may vary in length up to a maximum of 25’ (7.6 m).
2. By replicating these items, up to a total quantity of four ServeRAID-3HB Adapters (plus options) and eleven EXP15s can provide over 2 Terabytes of storage. Additional power and rack
space will be required.
3. Cable length requirements are dependant on component placement within the rack suite. To determine specific configuration requirements use the Netfinity Rack Configurator which is
downloadable from the Web site www.ibm.com/pc/us/netfinity/tech_library.html “Configuration Tools”.
Clustering is a group of interconnected computers used as a single, unified computing resource. Clustering Netfinity servers, like the IBM Netfinity 5500 M10, provides high availability solution
to keep you in touch with the key applications you need to run your business.
This sample configuration consists of paired IBM Netfinity 5500 M10 cluster nodes equipped with two-way SMP capability and redundant power supplies. Microsoft Cluster Service (MSCS) has
been validated on IBM Netfinity 5500 M10 servers, using the Netfinity ServeRAID-3HB Storage Expansion Unit. MSCS allows two configured servers, referred to as nodes, to be connected
together to form a cluster. Providing system redundancy means that a complete server can fail and client access to server resources is largely unaffected. MSCS extends this theme by also
allowing for software failures at an application level as well as an operating system level. If the operating system fails, all applications and services can be restarted on another server, and if just
one application fails, it can be managed by MSCS individually. An additional independent network connection is used to perform monitoring within the cluster. One or more disk subsystems are
attached to both nodes. In the above example, a Netfinity EXP15 was selected and the Netfinity ServeRAID-3HB Ultra2 SCSI Adapters provide the I/O control. Netfinity ServeRAID-3HB handles
the “SCSI heartbeat” connection without the need for a dedicated SCSI connection and logically attaches to the quorum disk, whi ch allows arbitration when a failure occurs. Additional
information on IBM Netfinity and IBM PC Server Clustering Solutions may be found on the World Wide Web by accessing URL www.ibm.com/pc/us/netfinity/clustering.html.
Updated 01/01/00
For the latest product & technical information, refer to the Information Sources on pages 1 and 2.
51
IBM Netfinity 5500 M20 Configurator
)
VD
, L a il)
)
D
I
)
v
ax
A
)
ar
ax
l/A d/M
,R
tP
D,
t
nd
/M
ta
a
n
MM
D
a
r
o
S
2
d
I
e
(
t
H
lt
(T
)
s)
St
m
(
e
RD
,S
s,
bp
Hz
ys
y(
l, U
ge
rs
r iv
al
ot
R=
tit
(M
(M
)
u a a Ba k D
na
)
so
Sl
on
l)
)(
n
i
t
s
B
a
D
,
d
x
t
a
r
(
s
e
ai
i
ail
e
e
i
a
M
(K
rn
Op
Qu
e r Me d d D
Av l/Av
oc
we
/M
)
pe
(
e
/
l
m
e
r
l
l
r
o
d
h
y
E
S
e
r
P
th
c
r
ta ota
ro
cy
or ppl
fP
St
st
be
(ID
Ha
p(
nt
ble
ct
so
Ca
m
an
dE
(To (T
y(
Sy
ro
Fa r Su
es
Co ova rnal
wa
ar
nd
or
v.
OM
Nu
s: ots:
be EC C
c
I
o
S
u
d
y
R
t
e
m
m
o
b
S
t
m
m
e
d
r
A
r
t
B a Sl
Pr
Me
Ho
Fo Pow
Pa
Nu
On
SC
Re
In
CD
L2
Re
ns
Fa
)
ax
d/M
t
S
)
ce
ro
d)
ss
8662-31Y
500
1/4
512
256 MB(R) /4 GB
Tower3
1/2
P, S, H, F
S-Fans,
O-Power
Y
10/100
D, R
4/2
0/109 GB4 32X-14X5 10/ 8
6/6
8662-3RY1
500
1/4
512
256 MB(R)/4 GB
Rack
(8U)
1/2
P, S, H, F
S-Fans,
O-Power
Y
10/100
D, R
4/2
0/109 GB
32X-14X5 10/ 8
6/6
8662-41Y
500
1/4
1024
256 MB(R)/4 GB
Tower3
1/2
P, S, H, F
S-Fans,
O-Power
Y
10/100
D, R
4/2
0/109 GB4 32X-14X5 10/ 8
6/6
8662-4RY1
500
1/4
1024
256 MB(R)/4 GB
Rack
(8U)
1/2
P, S, H, F
S-Fans,
O-Power
Y
10/100
D, R
4/2
0/109 GB
32X-14X5 10/ 8
6/6
8662-51Y
550
1/4
512
256 MB(R)/4 GB
Tower3
1/2
P, S, H, F
S-Fans,
O-Power
Y
10/100
D, R
4/2
0/109 GB4 40X-17X5 10/ 8
6/6
8662-5RY1
550
1/4
512
256 MB(R)/4 GB
Rack
(8U)
1/2
P, S, H, F
S-Fans,
O-Power
Y
10/100
D, R
4/2
0/109 GB
40X-17X5 10/ 8
6/6
8662-61Y
550
1/4
1024
256 MB(R)/4 GB
Tower3
1/2
P, S, H, F
S-Fans,
O-Power
Y
10/100
D, R
4/2
0/109 GB4 40X-17X5 10/ 8
6/6
8662-6RY1
550
1/4
1024
256 MB(R)/4 GB
Rack
(8U)
1/2
P, S, H, F
S-Fans,
O-Power
Y
10/100
D, R
4/2
0/109 GB
40X-17X5 10/ 8
6/6
1. Housed in a 19” Rack mountable drawer and ships standard without a keyboard or mouse. See “Rack and NetBAY” under “Netfinity 5500 M20 Power, Monitor & Accessories” for
supported IBM racks.
2. Intel Pentium III Xeon processor.
3. Tower models come equipped with a single NetBAY3 (3U) stackable enclosure. Up to a maximum of three are supported.
4. With a single Netfinity EXP15 installed in the standard NetBAY3 the maximum internal storage increases by 364 GB.
5. Variable read rate. Actual playback speed will vary and is often less than the maximum possible.
Part
Number
Processor Upgrades with 512 KB or 1 MB Cache
SMP
Support1
Processor Speed/Cache
Upgrade2
10L5901
Netfinity 5500 450 MHz/512 KB Upgrade with Pentium II Xeon Processor3
-
Footnote 3
10L5902
Netfinity 5500 450 MHz/1 MB Upgrade with Pentium II Xeon Processor3
-
Footnote 3
33L5053
Netfinity 500 MHz/512 KB Upgrade with Pentium III Xeon Processor
All 3xY
-
33L5054
Netfinity 500 MHz/1 MB Upgrade with Pentium III Xeon Processor
All 4xY
All 3xY
33L5107
Netfinity 550 MHz/512 KB Upgrade with Pentium III Xeon Processor
All 5xY
All 3...4xY
33L5108
Netfinity 550 MHz/1 MB Upgrade with Pentium III Xeon Processor
All 6xY
All 3...5xY
1. Up to three additional processors may be installed, providing a maximum of four. All processors must be identical in type, speed and cache size.
2. Requires removal of the standard processor. A maximum of four processors may be installed. All processors must be identical in type, speed and cache size.
Upgrades may require a BIOS update. To obtain the latest Flash BIOS, access www.ibm.com/pc/support and enter machine “Type-Model” in Quick Path. Select
“Downloadable files” and then “BIOS”.
3. Although supported by all Netfinity 5500 M20 models, these processors are intended for use with Netfinity Four-Way Processor Ugrade Kit (P/N 28L1014) to provide
investment protection when upgrading 5500 M10 models already containing one or more of these processors.
52
Std. Processor P1 Processor Slot
P2 Processor Slot
P3 Processor Slot
P4 Processor Slot
Netfinity 5500 M20 Processor Upgrades
Installation
Sequence:
P1-P4-P2-P3
Netfinity 5500 M20 Memory
Total
Memory1
RDIMM Slot 1 Std. RDIMM
RDIMM Slot 2
RDIMM Slot 3
RDIMM Slot 4
RDIMM Slot 5
RDIMM Slot 6
RDIMM Slot 7
RDIMM Slot 8
All Models
256 MB
256 MB RDIMM Standard
384 MB
1 x 01K7262
512 MB
1 x 01K8043
768 MB
1 x 01K7263 or 2 x 01K80433
1280 MB
2 x 01K7263 or 4 x 01K80433
01K7262
Netfinity 128 MB SDRAM ECC RDIMM1
1792 MB
3 x 01K7263 or 6 x 01K80433
01K8043
Netfinity 256 MB SDRAM ECC RDIMM1
2048 MB
(3 x 01K7263, 1 x 01K8043) or 7 x 01K80433
01K7263
RDIMM1
3072 MB
5 x 01K7263, 1 x 01K8043
4096 MB
8 x 01K72632
Part Number
Memory Description
Netfinity 512 MB SDRAM ECC
1. DIMMs should be installed in the following sequence beginning with Slot 1
and ordered from largest to smallest: 1-5-2-6-3-7-4-8.
This table does not represent all possible memory configurations.
1. Network Operating Systems may limit the maximum amount of addressable memory. See
operating system specifications for further information.
2. Replace standard DIMM.
3. Memory modules may vary in price per MB. Selection of smaller RDIMMs may provide a
more cost-effective alternative to using the largest RDIMMs and should be considered when
anticipated future memory is 2 GB or less.
Netfinity 5500 M20 Hard Disk Drive (HDD) Storage
Total
Internal
Storage1
7200 RPM Hard Disk Drives
(HDDs)
9.1 GB
0 GB
9.1 GB
18.2 GB
9.1 GB
Standard on Base Models
1 x 01K8053
-
18.2 GB
2 x 01K8053 or 1 x 02K0440
27.2 GB
3 x 01K8053
-
36.4 GB
4 x 01K8053 or 2 x 02K0440 or
45.5 GB
5 x 01K8053
54.6 GB
6 x 01K8053 or 3 x 02K0440
72.8 GB
36.4 GB
10,000 RPM Hard Disk Drives
(HDDs)
-
4 x 02K0440 or
91 GB
-
5 x 02K0440
109 GB(max)
-
6 x 02K0440 or
18.2 GB
36.4 GB
Standard on Base Models
-
1 x 36L9806
2 x 36L9806 or
-
3 x 36L9806
1 X 02K0441 4 x 36L9806 or
-
5 x 36L9806
-
6 x 36L9806 or
2 X 02K0441
-
1 x 36L9807
2 x 36L9807 or
3 x 36L9807
4 x 36L9807 or
-
-
5 x 36L9807
3 X 02K0441
-
6 x 36L9807 or
1 x 36L9808
2 x 36L9808
3 x 36L9808
IBM NETFINITY 5500 M20
This table does not represent all possible hard drive configurations.
1. Total Internal Storage listed is within + 0.2 GB unless otherwise noted.
Updated 01/01/00
For the latest product & technical information, refer to the Information Sources on pages 1 and 2.
53
Bay
Form
Factor
Height
-
3.5”
SL
Yes
Diskette
-
5.25”
HH
Yes
IDE CDROM
01K8053
A
5.25”
HH1
Yes
Open
B
5.25”
HH
1
Yes
1...6
HS
SL2
Yes
NB33
19” Rack
Front Usage
Access
3U
Yes
RPM
Height
Netfinity 9.1 GB Wide Ultra SCSI
SCA-2 SL HDD
7200
SL
1...6
6
02K0440
Netfinity 18.2 GB Wide Ultra
SCSI Hot-Swap SL HDD
7200
SL
1...6
6
Open
02K0441
Netfinity 36.4 GB Wide Ultra
SCSI Hot-Swap HDD
1/2, 3/4, 5/6
3
Open
36L9806
Open
1. Two half-high (HH) bays can be combined to support a single full-high
(FH) device.
2. Two slim-line (SL) bays can be combined to support a single half-high
(HH) device.
3. One NetBAY3 is included with tower models and a total of three are
supported. See IBM Netfinity NetBAY3 Stackable Enclosure section for
supported devices.
Part
Number
Description
Internal Hard Disk Drives
(HDD)
Diskette
CD-ROM
Bay A
Bay B
Hot Swap
(HS)
Bay 1
Bay 2
Bay 3
Bay 4
Bay 5
Bay 6
Netfinity NetBAY3 (NB3)
(Tower Models Only)
1
7200
HH
Netfinity 9.1 GB 10K-3 Wide
Ultra SCSI Hot-Swap SL HDD
10,000
SL
1...6
6
36L9807
Netfinity 18.2 GB 10K-3 Wide
Ultra SCSI Hot-Swap SL HDD
10,000
SL
1...6
6
36L9808
Netfinity 36.4 GB 10K-3 Wide
Ultra SCSI Hot-Swap HDD
10,000
HH1
1/2, 3/4, 5/6
3
External Storage
Expansion Units2
Removable
Media(RM)
Bays
Max.
Supported Qty.
Form
Factor
35202RU
Netfinity EXP15 Storage
Expansion Unit
Rack (3U)
35301RU
Netfinity EXP200 Storage
Expansion Unit
Rack (3U)
37L5857
Netfinity EXP200 Rack-to-Tower
Conversion Kit
Tower
1. Two slim-line (SL) bays can be combined to support a single half-high (HH) device.
2. Supported by the onboard external SCSI port. Select the onboard or optional SCSI controller then refer to
Appendix D: Cables-Storage Units-Controllers to confirm the controller supports the desired External Storage
Expansion Unit and to select a supported cable. For HDD or other expansion unit options, see the specific
expansion unit section.
Internal SCSI Cabling
Netfinity 5500 M20 systems contain a backplane supporting six hot-swap drive bays. The backplane is connected to one of the two connectors of the integrated
dual-channel ServeRAID controller through a 16-bit SCSI cable. A two-drop 16-bit SCSI cable, with an integrated terminator, is included with the server to support up
to two internal removable media devices connected to the second RAID connector or a supported SCSI adapter. The standard cabling routes the second RAID
connector to the rear panel cutout providing an external 16-bit VHDCI 0.8 mm connector. If internal removable media devices are required, in addition to external
RAID device attachment, a supported SCSI adapter must be installed using the standard two-drop SCSI cable for device/adapter connection. If connecting narrow
devices to this cable, additional 68-pin to 50-pin converters (P/N 32G3925) must be ordered. Some narrow devices include a converter in their ship group.
54
Netfinity 5500 M20 I/O Options
Part
Number
Description
Adapter
PCI
Slots
Length Support Supported1
Hot-Plug2
1...4
X
32/64-bit
1...4
X
02K3454
PCI Fast/Wide Ultra SCSI Adapter
Half
32-bit
1...5
-
01K7297
Netfinity Fibre Channel PCI Adapter7
Half
32/64-bit
1...5
-
09L2123
Advanced SerialRAID/X Adapter
Full
32-bit
1...4
Ethernet
34L1501
Netfinity 10/100 Ethernet PCI Adapter 2
Half
32-bit
1...5
08L3341
Netfinity 10/100 Fault Tolerant Adapter
Half
32-bit
1...5
X
X
34L0301
Netfinity Gigabit Ethernet SX Adapter
Half
32/64-bit
1...5
X
ISA - Full Length
Networking8
Slot 4 - PCI, Hot- Plug, 32-bit, Full Length
32-bit
Full
Slot 5- PCI, Primary Bus, Half Length
Full
Netfinity ServeRAID-3HB Ultra2 SCSI Adapter6
Slot 3 - PCI, Hot- Plug, 32-bit, Full Length
Netfinity ServeRAID-3L Ultra2 SCSI Adapter4, 5
37L6086
Slot 2 - PCI, Hot- Plug, 32-bit, Full Length
01K7364
Slot 1- PCI, Hot- Plug, 32-bit, Full Length
Storage Controllers3
Token Ring
34L0501
Token-Ring 100/16/4 High-Speed PCI Adapter
Half
32-bit
1...5
-
34L0601
Token-Ring 16/4 PCI Adapter 2
Half
32-bit
1...5
-
33L4618
PCI V.90 56 Data/Fax Modem9
Half
32-bit
1...5
-
37L1414
Serial I/O SST8P DB Adapter10
Half
32-bit
1...610
-
37L1415
Serial I/O sst16P RJ Adapter
Half
32-bit
1...610
-
37L1423
Serial I/O SST16P DB Adapter
Half
32-bit
1...610
-
37L1416
Serial I/O sst128P Expandable Adapter
Half
32-bit
1...610
-
Full
32-bit
1...413
Communications
Systems Management11
01K7209
Netfinity Advanced System Management PCI Adapter12
03K9309
Netfinity Advanced System Management Interconnect
Cable Kit14
-
-
-
-
36L9654
Netfinity Advanced System Management Token-RIng
Connection15
-
-
-
-
9086001
Netfinity ESCON Adapter16
Full
32-bit
1...617
-
1. PCI Slots 1, 2, 3 and 4 support Hot Plug devices.
2. Hot Plug capable using IBM’s Active PCI technology. For Network Operating System support access URL www.ibm.com/pc/us/compat.
3. Netfinity 5500 and 5500 Mxx have a dual channel ServeRAID II Wide Ultra SCSI controller.
4. All ServeRAID-3x adapters can be upgraded with the same enhanced software utillities and firmware included with ServeRAID-3HB. The download is available for no charge from
www.ibm.com/pc/support. Select “Server” in Brand pulldown, “ServeRAID’ in the Family pulldown and then “Downloadable files”. The upgrade should be considered for installations with
firmware less than Version 3.5.
5. Netfinity ServeRAID-3L Ultra2 SCSI Adapter (P/N 01K7364) provides either one internal or one external (0.8 mm VHDCI) LVDS SCSI channel.
6. Netfinity ServeRAID-3HB Ultra2 SCSI Adapter (P/N 37L6086) provides one internal and two external (0.8 mm VHDCI) LVDS SCSI channels.
The internal channel can be configured for external usage (0.8mm VHDCI connector) providing a total of three external LVDS SCSI channels. Includes 32MB of mirrored battery-backup
cache, which helps protect against data loss in write-back cache mode in the event of a power outage or adapter maintanance.
7. See Netfinity Fibre Channel Solutions section for additional configuration information.
8. Netfinity 5500 and 5500 Mxx have an integrated 10/100 PCI Ethernet Controller.
9. Due to homologation variances, modem availability may differ by country.
10. See Appendix E for details on Serial I/O options and configuration limitations. A maximum of four Serial I/O adapters (any combination of P/N 37L1414, 37L1415, 37L1416, 37L1423) may be
installed.
11. The Netfinity Advanced System Management Processor and Interconnect Bus integrated into Netfinity 5500 (8660-5...6xU) and 5500 Mxx works with Netfinity Manager to provide
significant system management function. When used with optional Netfinity Advanced System Management PCI Adapter (P/N 01K7209) and Netfinity Advanced System Management
Interconnect Cable Kit (P/N 03K9309) additional management and control of up to 12 service processors from a remote console through a single modem or LAN connection is possible.
Systems management options P/N 01K7209, 03K9309 and 36L9654 are NOT supported by Netfinity 5500 models 8660-1...4xU.
12. Includes PCI adapter, Netfinity Advanced System Management Interconnect Cable Kit components and 56-watt AC adapter, which requires a separate power source. Provides an
integrated 10/100 Ethernet port and a PCMCIA slot to support optional Netfinity Advanced System Management Token-Ring Connection (P/N 36L9654). NOT supported by Netfinity models
8660-1...4xU.
13. A maximum quantity of one is supported.
14. Required for all Netfinity servers containing a standard Advanced System Management Processor that are to be interconnected for system management support through a LAN or
modem connection (Netfinity 5500 models 8660- 1...4xU are not supported). Optional Netfinity Advanced System Management PCI Adapter (P/N 01K7209) includes the content of this
option. Up to 12 service processors may be interconnected (including standard and optional processors) with an aggregate connection length of no more than 91.4 meters (300 ft.). A
customer-supplied Ethernet cable is required for each interconnection.
15. Contains an IBM Turbo 16/4 Token-Ring PCI Card, which installs in the PCMCIA card slot of Netfinity Advanced System Management PCI Adapter (P/N 01K7209), and a PC Card to 9-pin
D-Shell cable which is routed to a rear chassis cut-out. The Netfinity Advanced System Management PCI Adapter’s integrated Ethernet port and Netfinity Advanced System Management
Token-Ring Connection cannot be connected or used together.
16. Provides an ESCON MIC and a DB9 Serial Port. Cables are not included but are available through S390 channels. Contact your IBM representative for additional information.
17. A maximum of two 9086001 adapters (installed in non-adjacent slots) are supported in a single Netfinity server.
Updated 01/01/00
For the latest product & technical information, refer to the Information Sources on pages 1 and 2.
55
IBM NETFINITY 5500 M20
Host Attach
Netfinity 5500 M20 Power, Monitor & Accessories
Part
Number
Description
Part
Number
Power1
Conversion Kits
01K7953
Netfinity 500 W Hot-Swap Redundant Power Supply 2
01K8021
Netfinity 5500 Rack-to-Tower Kit1
Uninterruptible Power Supply (UPS)3
01K8020
Netfinity 5500 Tower-to-Rack Kit
94G3136
APC Smart-UPS 1400 (20 min. runtime at 450 Watts)
Rack and NetBAY2
94G6674
APC Smart-UPS 1400RMB (15 min. runtime at 450
Watts)4
930842P
Netfinity Enterprise Rack
94G6676
APC Smart-UPS 3000RMB (45 min. runtime at 450 Watts)4
930842X
Netfinity Enterprise Expansion Cabinet
Monitors
9306900
Netfinity Rack
9306200
Netfinity NetBAY22
65464AN
G54 Color Monitor 15’’ (13.7” Viewable Image Size), stealth black5
10L6912
Netfinity NetBAY33
65474AN
G74 Color Monitor 17” (15.9 Viewable Image Size), stealth black5
10L6913
Netfinity Caster Set
65494AN
G96 Color Monitor 19” (17.9” Viewable Image Size), stealth black6
9513AG1
T55A Flat Panel Color Monitor (15.0” Viewable Image Size), stealth
Keyboard and Mouse4
black7
Cables8
32G3925
28L3644
Space Saver II Keyboard5, 7
01K1260
TrackPoint IV 104-Key Black Keyboard6, 7
SCSI 68-pin to 50-pin Converter
1. Netfinity 5500 M20 includes a single 500W power supply which is sufficient to operate fully configured
systems. If power supply redundancy is desired, optional power supply P/N 01K7953 is required.
2. Includes a power cord which requires an additional power source. Even though a second UPS
provides a redundant power source, systems management software does not currently take advantage of
its power outage alerts.
3. Stated runtimes and power are for typical configurations (approximately 70% of maximum capacity).
For additional information see Appendix C: UPS Runtime Estimate.
4. Height is 3U. See “Rack and NetBAY” for supported IBM racks.
5. Installation within a rack requires optional Monitor Compartment (P/N 94G7444).
6. Not supported for installation in a 19” rack.
7. Installation within a rack requires optional Netfinity Flat Panel Monitor Rack Mount Kit (P/N 37L6857) and
Netfinity Rack Keyboard Tray (P/N 28L4707). A space saver keyboard may coexist within the same
28L4707 keyboard tray.
8. Netfinity 5500 M20 comes with an external 0.8 mm VHDCI port cabled to the second onboard RAID
SCSI port.
56
Description
28L3621
Preferred Keyboard (stealth black)6
28L3673
Sleek 2-Button Stealth Black Mouse
1. Includes one Netfinity NetBAY3 with skid pads. Optional casters (P/N 10L6913)
are available.
2. Netfinity 5500 and 5500 Mxx rack models are housed in a 19” rack mountable
drawer and require one of the racks listed here.Tower models include a single
NetBAY3 with skid pads. Optional casters (P/N 10L6913) are available. See IBM
Netfinity Rack Cabinet and Options section for IBM rack NetBAY3 with skid
pads.Optional casters (P/N 10L6913) are available. See IBM Netfinity Rack
supported devices.
3. A maximum of three NetBAY3 enclosures (including the standard one) may be
stacked beneath a supported Netfinity tower server. Casters are not included. See
IBM Netfinity NetBAY3 Stackable Enclosure section for supported devices.
4. Tower models include both a mouse and a keyboard. Rack models include
neither.
5. Installation within a rack requires optional keyboard tray P/N 28L4707 (stows in
“ready-to-use” position).
6. Installation within a rack requires optional keyboard tray P/N 28L4707. This
keyboard cannot share a keyboard tray with a flat panel display.
7. Advanced TrackPoint IV features are not available on IBM Netfinity systems.
Netfinity 5500 M20 Tape Options
Part
Number
Description
Bays
Supported
SCSI
Interface
(bit)
Form
Factor
Termination 68/50- pin Ext. Tape
Included
Converter
Encl.1
Incl.
01K1282
12/24 GB DDS/3 4-mm Internal Tape Drive
A, B
8
3.5” HH or
5.25” HH
Y2
Y
3510020
01K1325
20/40 GB 8-mm Internal SCSI Tape Drive
A, B
16
5.25” HH
N3
N
35100204,
3551001
01K1320
20/40 GB DLT Internal SCSI Tape Drive
A/B5
8
5.25” FH
Y2
Y
3503B0X,
3551001
04K0149
35/70 GB DLT Internal SCSI Tape Drive
A/B5
16
5.25” FH
N3
N
3503B0X4,
3551001
00N7990
40/80 GB DLT Internal SCSI Tape Drive
A/B5
16 LVD
5.25” FH
N3
N
3503B0X4,
3551001
32G3918
SCSI-2 16-bit Active Terminator
-
16
External
Y
N
3510020,
3503B0X
3510020
External Half High SCSI Storage Enclosure6
-
8/16
Desktop
N
N
-
3551001
NetMEDIA Storage Expansion Unit EL7
-
16
Rack
Y
N
-
10L7113
NetMEDIA Systems Management Adapter8
-
16
-
N
N
3551001
DLT External SCSI Enclosure9
-
16
Desktop
N
N
-
-
16
Desktop
Y
-
-
Associated Options
External Tape Enclosures
3503B0X
External Tape Libraries10
3502108
DLT Tape Autoloader
3502x14
DLT Tape Library
-
16
Desktop or
Rack
Y
-
-
3503108
DLT8000 Tape Autoloader
-
16 LVD
Desktop
Y
-
-
Y
-
-
Y
-
-
3503x14
DLT8000 Tape Library
-
16 LVD
Desktop or
Rack
3570xxx
Magstar MP 3570 Tape Subsystem
(models B2x and C2x)
-
Diff.
Rack
1. To determine cable requirements, note the tape drive’s SCSI interface, the appropriate SCSI controller from the system configurator section, and the desired enclosure and then refer to
Appendix D: Cables - Storage Units - Controllers.
2. Tape drive is capable of self termination.
3. Termination is provided by the system unit’s standard SCSI cabling.
4. Requires SCSI-2 16-bit Active Terminator (P/N 32G3918).
5. Two Half-High (HH) bays can be combined to support a single Full-High (FH) device.
6. Provides a black desktop 5.25” half-high (HH) tape enclosure. Connector is configurable as 50-pin Centronix or 68-pin high density. Requires either tape drive self termination or SCSI-2
16-bit Active Terminator (P/N 32G3918).
7. Provides a black 3U, 19” rack or NetBAY3 mountable tape enclosure. Provides two full high (FH) or four half high (HH) extended length 5.25” bays. External connector is 0.8-mm VHDCI.
Includes two power supplies and two power cords.
8. Installs in a 3551001. Provides repeater function and LVDS interface allowing longer cable lengths and auto-termination when the 3551001 is powered off.
9. Provides a black desktop DLT tape enclosure with a 68-pin high density external connector. Requires termination by the tape drive or by installation of a SCSI-2 16-bit Active Terminator
(P/N 32G3918).
10. Tape library attributes and prerequisites are located in Appendix B: Tape Library Attributes.
IBM NETFINITY 5500 M20
NOTE: SCSI support for tape drives is provided by system unit onboard (standard) controller (no-RAID function) or PCI Fast Wide Ultra SCSI Adapter P/N 02K3454. Additional tape attributes
can be found in Appendix A: Tape Drive Attributes.
Updated 01/01/00
For the latest product & technical information, refer to the Information Sources on pages 1 and 2.
57
Sample Configurations
Note: The following sample configurations are for illustration only and may not be suitable for any specific customer installation. Contact your IBM Business Partner
or IBM Marketing Representative for assistance with your specific configuration requirements.
High Availability
Part Number
Description
Quantity
Usage
8662-31Y
Netfinity 5500 M20 (Pentium III Xeon 500/512 KB 256 MB Tower & NetBAY3)
1
-
01K8053
Netfinity 9.1 GB Wide Ultra SCSI SCA-2 SL HDD
2
NOS on mirrored HDD’s
RAID 5 with Hot-Spare
36L9806
Netfinity 9.1 GB 10K-3 Wide Ultra SCSI Hot-Swap SL HDD
4
01K1320
20/40 GB DLT Internal SCSI Tape Drive
1
-
7852400
External V.34 Data/Fax Modem
1
Remote Management
01K7953
Netfinity 500W Hot-Swap Redundant Power Supply
1
-
10L6912
Netfinity NetBAY3
1
Enclosure for second UPS
94G6674
APC Smart-UPS 1400RMB1
2
Redundant UPS’s
65464AN
G54 Color Monitor 15” (13.7” Viewable Image Size), stealth black
1
1. Even though a second UPS provides a redundant power source, systems management software does not currently take advantage of its power outage alerts.
This tower server is configured to act as the foundation for business critical applications, applications your business cannot afford to be without. Configured with
enough disk drives to mirror the operating system and provide a standard RAID 5 environment for data, optional hot-swap redundant power and redundant UPSs for
power even during a blackout or in the event of a UPS or power cord failure, this server represents the leading edge in high availability. An internal tape drive is
included to back-up that all important asset..... data, and a modem is included to allow out-of-band (non-LAN) system management utilizing the Netfinity Advanced
System Management Processor.
Consolidation Server
Part Number
Description
Quantity
Usage
8662-61Y
Netfinity 5500 M20 (Pentium III Xeon 550/1 MB 256 MB Tower & NetBAY3)
1
-
33L5108
Netfinity 550 MHz/1 MB Upgrade with Pentium III Xeon Processor
3
-
01K7263
512 MB SDRAMM ECC RDIMM
3
Total Memory: 2GB
01K8043
256 MB SDRAMM ECC RDIMM
1
Total Memory: 2GB
> 100GB Interal Storage
02K0440
Netfinity 18.2 GB Wide Ultra SCSI Hot-Swap SL HDD
6
00N7990
40/80 GB DLT Internal SCSI Tape Drive
1
-
01K7953
Netfinity 500W Hot-Swap Redundant Power Supply
1
-
94G6676
APC Smart-UPS 3000RMB
1
Installed in NetBAY3
65464AN
G54 Color Monitor 15” (13.7” Viewable Image Size), stealth black
1
-
This tower model is configured to meet the need of server consolidation. Many businesses are trying to get their arms around the dispersed departmental servers
that have grown-up around the enterprise. By moving multiple servers onto one platform there is only one system to manage, both hardware and software. There is
potentially less expensive for service, software licenses, etc., and there is no need to worry about putting all your eggs in one basket because the Netfinity 5500
M20 is designed for high availability. This configuration can accommodate over 100 GB of data storage, features a second power supply which provides fully
redundant power, a UPS to insure the system continues to run even if there is a momentary electricity loss, and an internal tape drive that backs up to 70 GB per
tape...in addition to all the standard features of the Netfinity 5500 M20.
58
Two Node High Availability Cluster
Public
LAN
Server Node A
CH3
ServeRAID-3HB
(37L6086)
CH2
CH1
10/100 Ethernet (34L1501)
Integrated10/100 Ethernet
(03K9311)
(25’ Ethernet
Crossover Cable1)
Netfinity EXP 15
Server Node B
CH3
CH2
CH1
Integrated10/100 Ethernet
(37L6086)
ServeRAID-3HB
10/100 Ethernet (34L1501)
Public
LAN
1.Customer supplied Ethernet Crossover Cable may vary in length up to a maximum of 25’ (7.6 m).
Two Node High Availability Cluster
Part Number
Description
Quantity.
Usage
Server Nodes A & B
8662-6RY
Netfinity 5500 M20 (Pentium III Xeon 550/1 MB 256 MB Rack)
2
-
33L5108
Netfinity 550 MHz/1 MB Upgrade with Pentium III Xeon Processor
2
Dual SMP Processing
Total Memory: 384 MB (each)
01K7262
Netfinity 128 MB SDRAM ECC RDIMM
2
01K8053
Netfinity 9.1 GB Wide Ultra SCSI SCA-2 SL HDD
4
NOS on mirrored HDDs
37L6086
Netfinity ServeRAID-3HB Ultra2 SCSI Adapter2
2
Three channels for EXP15s
34L1501
Netfinity 10/100 Ethernet PCI Adapter 21
2
Private Interconnect
00N7990
40/80 GB DLT Internal SCSI Tape Drive
02K3454
PCI Fast/Wide Ultra SCSI Adapter
1
Tape Drive Controller
7852400
External V.34 Data/Fax Modem
2
Remote Management
01K7953
Netfinity 500W Hot-Swap Redundant Power Supply
2
-
94G6676
APC Smart-UPS 3000RMB (3U)
2
-
35202RU
Netfinity EXP152 (3U)
1
-
01K7959
Netfinity EXP10 9.1 GB Wide Ultra SCSI SCA-2 HDD2
5
RAID 5 Shared Storage
03K9311
Netfinity 4.2M Ultra2 SCSI Cable2
2
Attach EXP15 to Servers
Storage Expansion Unit
Shared (or single occurrence) Resources
9513AG1
T55 Flat Panel Color Monitor (15.0” Viewable Image Size), stealth black
1
Mounts in keyboard tray
28L3644
Space Saver II Keyboard
1
Mounts in keyboard tray
9306900
9306-900 Netfinity Rack
1
-
28L4707
Netfinity Rack Keyboard Tray
1
Mounts in keyboard tray
37L6857
Netfinity Flat Panel Monitor Rack-Mount Kit (3U)
1
28L0542
Netfinity Console Server Selector Switch (4-port)
1
-
94G6667
Power Cable-Type A14 3
3
-
94G7447
12ft. Console Cable Set
2
-
94G6669
Side Panel Kit
1
-
94G6670
Blank Filler Kit
2
-
1. Requires customer supplied Ethernet Crossover Cable which may vary in length up to a maximum of 25’ (7.6 m).
2. By replicating these items, up to a total quantity of four ServeRAID-3HB Adapters (plus options) and eleven EXP15s can provide over 2 Terabytes of storage. Additional power and
rack space will be required.
3. Cable length requirements are dependent on component placement within the rack or rack suite. To determine specific configuration requirements use the Netfinity Rack
Configurator which is downloadable from the Web site www.ibm.com/pc/us/netfinity/tech_library.html “Configuration Tools”.
Clustering is a group of interconnected computers used as a single, unified computing resource. Clustering Netfinity servers, like the IBM Netfinity 5500 M20, provides a high availability solution
to keep you in touch with the key applications you need to run your business.
This sample configuration consists of paired IBM Netfinity 5500 M20 cluster nodes equipped with two of the possible four SMP processors and redundant power supplies. Microsoft Cluster
Service (MSCS) has been validated on IBM Netfinity 5500 M20 servers, using the Netfinity ServeRAID-3HB with the EXP15 Storage Expansion Unit. MSCS allows two configured servers,
referred to as nodes, to be connected together to form a cluster. Providing system redundancy means that a complete server can fail and client access to server resources is largely unaffected.
MSCS extends this theme by also allowing for software failures at an application level as well as an operating system level. If the operating system fails, all applications and services can be
restarted on another server, and if just one application fails, it can be managed by MSCS individually. An additional independe nt network connection is used to perform monitoring within the
cluster. One or more disk subsystems are attached to both nodes. In the above example, a Netfinity EXP15 was selected and the IBM ServeRAID-3HB Ultra2 SCSI Adapters provide the I/O
control. Netfinity ServeRAID-3HB handles the “SCSI heartbeat” connection without the need for a dedicated SCSI connection and logically attaches the quorum disk, which allows arbitration
when a failure occurs. Additional information on IBM Netfinity and IBM PC Server Clustering Solutions may be found on the World Wide Web by accessing
URL www.ibm.com/pc/us/netfinity/clustering.html.
Updated 01/01/00
For the latest product & technical information, refer to the Information Sources on pages 1 and 2.
59
IBM NETFINITY 5500 M20
Industry Standard 19” Rack, EIA-310D, Min. depth of 28”
IBM Netfinity 5600 Configurator
)
)
VD
ax
)
)
or
,L
s
s
)
)
)
D
n
s
a il d ./ M
I
x
d
x
e
a
)
v
r
a
A
a
t
F
c
A
M
,
l/ S
da
ro
,R
./M
./M
IM
ta e (
DD
an
td
td
tP )
tra
RD
2
(ToD riv
St
(S
,H
(S
Ul
en bps
,
=
s
)
s
y
l
,
s
t
t
z
l
y
m
r
k
R
ti
e
lo
M
H
na
ua
so )
)(
Ba Dis
t(
an
ag
(M
,S
tio
il)
a
(D
l)
es KB
ax
er
a n r ne
di ar d
Qu
va
ai
ed
Op
er
/M
oc he (
w
e
(
l
.
M
e
e
r
y
l
o
r
l
l/A l/Av
d
h
M lH
y
E)
p
r
P ac
o
t
P
p
t
a
m
r
c
(
S
o
D
f
t
be
e
S
a
a
e
l
(I
p
nt
up
ct
m
an
dE
To Tot
or
ro CC
st
y(
ab r n
M
Fa
Co
:(
rS
wa
nd
ss
Nu
or
Sy oar
be
:(
ov te
ys
m
m 2 EC
b
SI
t-S
RO
du
rt
ce
v.
we
m In
ts
rm
a
e
u
n
o
e
o
C
a
d
o
e
o
o
B
M
L
P
N
O
S
R
F
P
H
A
R
Sl
Pr
CD
8664-11Y
533EB
1/2
256
128 MB(R)/4 GB3
Tower
2/3
P, S,H,F
S-Power4
S-Fans
Y 10/100
D,U2,L
4/2
0/109 GB 40X- 17X5
10/8
5/5
8664-1RY1
533EB
1/2
256
128 MB(R)/4 GB3
Rack(5U)
2/3
P, S,H,F
S-Power4
S-Fans
Y 10/100
D,U2,L
4/2
0/109 GB 40X- 17X5
10/8
5/5
Y 10/100
D,U2,L
4/2
0/109 GB 40X- 17X5
10/8
5/5
S-Power4
8664-21Y
600EB
1/2
256
128 MB(R)/4 GB3
Tower
2/3
P, S,H,F
8664-2RY1
600EB
1/2
256
128 MB(R)/4 GB3
Rack(5U)
2/3
P, S,H,F
S-Power4
S-Fans
Y 10/100
D,U2,L
4/2
0/109 GB 40X- 17X5
10/8
5/5
8664-31Y
667
1/2
256
256 MB(R)/4 GB3
Tower
2/3
P, S,H,F
S-Power4
S-Fans
Y 10/100
D,U2,L
4/2
0/109 GB 40X- 17X5
10/8
5/5
8664-3RY
667
1/2
256
256 MB(R)/4 GB3 Rack(5U)
2/3
P, S,H,F
S-Power4
S-Fans
Y 10/100
D,U2,L
4/2
0/109 GB 40X- 17X5
10/8
5/5
S-Fans
1. Housed in a 19” Rack mountable drawer and ships standard without a keyboard or mouse. See “Rack and NetBAY” under “Netfinity 5600 Power, Monitor & Accessories” for supported IBM
racks.
2. Intel Pentium III processor with 133 Mhz front-side bus (FSB). Intel uses EB to designate the attributes of the 533 MHz and 600 MHz processors. E stands for advanced transfer (full-speed)
cache and B stands for 133 MHz front-side bus.
3. High-speed, 133 MHz SDRAM.
4. Robust configurations may require optional Netfinity 250W Hot-Swap Redundant Power Supply (P/N 33L3760) for redundancy. See “Power” under “Netfinity 5600 Power, Monitor &
Accessories” for additional information.
Netfinity 5600 Processor Upgrades
Part
Number
Processor Upgrades with 512 KB Cache
SMP
Support1
Processor Speed Upgrade2
10K2168
Netfinity 533EB MHz 133 FSB/256 KB Upgrade with Pentium III Processor
1xY
-
00N7948
Netfinity 600EB MHz133 FSB/256 KB Upgrade with Pentium III Processor
2xY
All 1xY
00N7949
Netfinity 667 MHz 133 FSB/256 KB Upgrade with Pentium III Processor
3xY
All 1...2xY
1. One additional processor may be installed, providing a maximum of two. All processors must be identical in type, speed, and cache size.
2. Requires removal of the standard processor. A maximum of two processors may be installed. All processors must be identical in type, speed and cache size. Upgrades may require a
BIOS update. To obtain the latest Flash BIOS, access www.ibm.com/pc/support and enter machine “Type-Model” in Quick Path. Select “Downloadable files” and then “BIOS”.
60
RDIMM Socket 1 (J4)
RDIMM Socket 2 (J3)
Quantity of RDIMMs Added
128 MB
(1 x 128)
Models
Order RDIMMs in
sequence from largest
to smallest beginning
with J1.
RDIMM Socket 3 (J2)
RDIMM Socket 4 (J1) Std. RDIMM
Total
Memory1
128 MB
(33L3058)
256 MB
(33L3060)
512 MB
(33L3062)
1 GB
(33L3062)3
-
256 MB
1
-
-
384 MB
2 or
1
-
-
512 MB
3
-
-
-
640 MB
-
2 or
1
-
896 MB
-
3
-
-
1024 MB
-
42
-
-
1152 MB
-
-
2 or
1
1664 MB
-
-
3
-
2048 MB
-
-
42
-
2176MB
-
-
-
2
3200 MB
-
-
-
3
4096 MB (max)
-
-
-
42
This table does not represent all possible memory configurations.
1. Network Operating Systems may limit the maximum amount of addressable memory. See operating
system specifications for further information.
2. Requires removal of standard memory.
3. Planned availability of 4Q 1999.
Memory Description1
Part
Number
33L3058
Netfinity 128 MB, 133 MHz SDRAM ECC RDIMM
33L3060
Netfinity 256 MB, 133 MHz SDRAM ECC RDIMM
33L3062
Netfinity 512 MB, 133 MHz SDRAM ECC RDIMM
33L3064
Netfinity 1 GB, 133 MHz SDRAM ECC RDIMM2
1. Order RDIMMs in sequence from largest to smallest beginning with socket 4 (J1).
2. Planned availability of 4Q 1999
Netfinity 5600 Hard Disk Drive (HDD) Storage
Total Int.
Storage1
7200RPM Hard Disk Drives
(HDDs)
9.1 GB
0 GB
9.1 GB
18.2 GB
36.4 GB
10,000RPM Hard Disk Drives
(HDDs)
9.1 GB
Standard on Base Models
1 x 36L9744
-
-
1 x 36L9748
18.2 GB
2 x 36L9744 or 1 x 36L9745
-
2 x 36L9748 or
27.3 GB
3 x 36L9744
-
3 x 36L9748
-
36.4 GB
4 x 36L9744 or 2 x 36L9745 or
45.5 GB
5 x 36L9744
54.6 GB
6 x 36L9744 or 3 x 36L9745
72.8 GB
-
4 x 36L9745 or
91 GB
-
5 x 36L9745
109.2 GB
(max)
-
6 x 36L9745 or
18.2 GB
36.4 GB
Standard on Base Models
1 x 36L9746
4 x 36L9748 or
-
5 x 36L9748
-
6 x 36L9748 or
2 x 36L9746
3 x 36L9746
-
1 x 36L9749
2 x 36L9749 or
3 x 36L9749
4 x 36L9749 or
-
5 x 36L9749
-
6 x 36L9749 or
1 x 36L9750
2 x 36L9750
3 x 36L9750
This table does not represent all possible hard drive configurations.
1. Total Internal Storage listed is within + 0.2 GB unless otherwise noted.
Updated 01/01/00
For the latest product & technical information, refer to the Information Sources on pages 1 and 2.
61
IBM NETFINITY 5600
Netfinity 5600 Memory
Bay
Form
Factor
Height
Front
Access
Usage
A
5.25”
HH1
Yes
Open
B
5.25”
HH1
Yes
Open
-
5.25”
HH
Yes
IDE CDROM
-
3.5”
SL
Yes
Diskette
C...H
SL2
HS
Yes
Open
1. Two half-high (HH) bays can be combined to support a single full-high
(FH) device
2. Two slim-line (SL) bays can be combined to support a single half-high
(HH) device.
Part
Number
Diskette
B
CD-ROM
Hot-Swap
(HS)
Removable Media (RM)
C
D
Rack Model View
E
Bays
Supported
Max.
Qty.
Netfinity 9.1 GB Wide Ultra2 SCSI
Hot-Swap SL HDD
7200
SL
C...H
6
36L9745
Netfinity 18.2 GB Wide Ultra2
SCSI Hot-Swap SL HDD
7200
SL
C...H
6
36L9746
Netfinity 36.4 GB Wide Ultra2
SCSI Hot-Swap HDD
7200
HH1
C/D, E/F, G/H
3
36L9748
Netfinity 9.1 GB 10K-3 Wide Ultra2
SCSI Hot-Swap SL HDD
10,000
SL
C...H
6
36L9749
Netfinity 18.2 GB 10K-3 Wide
Ultra2 SCSI Hot-Swap SL HDD
10,000
SL
C...H
6
36L9750
Netfinity 36.4 GB 10K-3 Wide
Ultra2 SCSI Hot-Swap HDD
10,000
HH1
C/D, E/F, G/H
3
External Storage
Expansion Units2
Form
Factor
35202RU
Netfinity EXP15 Storage
Expansion Unit
Rack
(3U)
35301RU
Netfinity EXP200 Storage
Expansion Unit
Rack
(3U)
37L5857
Netfinity EXP200 Rack-to-Tower
Conversion Kit
-
1. Two slim-line (SL) bays can be combined to support a single half-high (HH) device.
2. Not supported by the onboard external SCSI port. Select an optional SCSI controller then refer to see
Appendix D: Cables-Storage Units-Controllers to confirm the controller supports the desired External Storage
Expansion Unit and to select a supported cable. For HDD or other expansion unit options, see the specific
expansion unit section.
A
B
F
C
D
E
F
H
G
CD-ROM
G
H
Height
36L9744
Removable Media (RM)
A
RPM
Internal Hard Disk
Drives (HDD)
Tower Model View
For clarity purposes, bay labels in
these diagrams are for reference by
the accompanying tables and are not
the actual labels. Refer to the
documentation shipped with the
system for further details on actual
labels.
Description
Diskette
Internal SCSI Cabling
The Netfinity 5600 contains a backplane supporting six hot-swap drive bays. The backplane is connected to the integrated dual channel, wide Ultra2 SCSI controller
connector through a 16-bit LVD SCSI cable. If internal RAID support is required, this cable can be used to connect to a supported RAID adapter rather than the
integrated SCSI controller. A two-drop, 16-bit SCSI cable with integrated terminator is also included with the server to support up to two internal removable media
devices. This cable can be attached to the integrated SCSI controller if a RAID adapter is used to support the internal hot-swap drive bays. It can also be used to
attach to a supported SCSI adapter if the integrated Ultra2 SCSI controller is utilized for the hot-swap bays. The second channel is available through an industrystandard 0.8-mm very high density connector interface (VHDCI) located on the rear panel for external use.
62
IBM NETFINITY 5600
Netfinity 5600 I/O Options
Slots
HotSupported Plug2
Netfinity ServeRAID-3L Ultra2 SCSI Adapter3, 4
5
32-bit
1...5
X
X
37L6086
Netfinity ServeRAID-3HB Ultra2 SCSI Adapter
Full
32/64-bit
1...5
02K3454
PCI Fast/Wide Ultra SCSI Adapter
Half
32-bit
1...5
-
01K7297
Netfinity Fibre Channel PCI Adapter6
Half
32/64-bit
1...5
-
09L2123
Advanced SerialRAID/X Adapter
Full
32-bit
1...57
-
Networking8
Ethernet
34L1501
Netfinity 10/100 Ethernet PCI Adapter 2
Half
32-bit
1...5
X
08L3341
Netfinity 10/100 Fault Tolerant Adapter
Half
32-bit
1...5
X
Netfinity Gigabit Ethernet SX Adapter
Half
32/64-bit
1...5
X
34L0301
Token Ring
34L0501
Token-Ring 100/16/4 High-Speed PCI Adapter
Half
32-bit
1...5
-
34L0601
Token-Ring 16/4 PCI Adapter 2
Half
32-bit
1...5
X
33L4618
PCI V.90 56K Data/Fax Modem10
Half
32-bit
1...5
-
37L1414
Serial I/O SST8P DB Adapter11
Half
32-bit
1...511
-
37L1415
Serial I/O SST16P RJ Adapter11
Half
32-bit
1...511
-
37L1423
Serial I/O SST16P DB Adapter11
Half
32-bit
1...511
-
37L1416
Serial I/O SST128P Expandable Adapter11
Half
32-bit
1...511
-
Rack Model
Slot 1- PCI, 32-bit, Full Length
Full
Storage Controllers1
01K7364
Slot 2- PCI, 32-bit, Full Length
PCI
Support
Slot 3- PCI, Hot-Plug, 32/64-bit, Full Length
Adapter
Length
Slot 4- PCI, Hot-Plug, 32/64-bit, Full Length
Description
Slot 5- PCI, Hot-Plug, 32/64-bit, Full Length
Part
Number
Communications9
Systems Management12
01K7209
Netfinity Advanced System Management PCI Adapter13
Full
32-bit
1...514
-
03K9309
Netfinity Advanced System Management Interconnect Cable Kit15
-
-
-
-
36L9654
Netfinity Advanced System Management Token-RIng Connection16
-
-
-
-
Full
32-bit
1...518
-
Host Attach
9086001
Netfinity ESCON Adapter17
1. Netfinity 5600 has two integrated Wide Ultra2 SCSI channels. One is internal and the other is external with a 0.8-mm Very High Density Connection Interface (VHDCI).
2. Three of the five PCI slots are 32/64-bit hot-plug capable using IBM’s Active PCI technology. For Network Operating System support access URL www.ibm.com/pc/us/compat.
3. All ServeRAID-3x adapters can be upgraded with the same enhanced software utilities and firmware included with ServeRAID-3HB. The download is available for no charge from
www.ibm.com/pc/support. Select “Server” in Brand pull-down, “ServeRAID” in Family pull-down and then “Downloadable files”. The upgrade should be considered for installations with
firmware less than Version 3.5.
4. Netfinity ServeRAID-3L Ultra2 SCSI Adapter (P/N 01K7364) provides either one internal or one external (0.8-mm VHDCI) LVDS SCSI channel.
5. Netfinity ServeRAID-3HB Ultra2 SCSI Adapter (P/N 37L6086) provides one internal and 2 external (0.8-mm VHDCI) LVDS SCSI channels. The internal channel can be configured for external
usage (0.8-mm VHDCI connector) providing a total of 3 external LVDS SCSI channels. Includes 32MB of mirrored battery-backup cache which helps protect against data loss in write-back
cache mode in the event of a power outage or adapter maintenance.
6. See Netfinity Fibre Channel Solutions section for additional configuration information.
7. A maximum quantity of four is supported.
8. Netfinity 5600 has an integrated 10/100 PCI Ethernet Controller.
9. Netfinity 5600 includes two USB ports, three high-speed serial/asynchronous ports, (two NS16550A compatible, one for the Advanced System Management Processor), and one highspeed (up to 2 MB/sec. data transfer speed) bi-directional parallel port supporting devices using ECP/EPP/SSP protocols adhering to the IEEE 1284 standard.
10. Due to homologation variances, modem availability may differ by country.
11. See Appendix E for details on Serial I/O options and configuration limitations. A maximum of four Serial I/O adapters (any combination of P/N 37L1414, 37L1415, 37L1416, 37L1423) may be
installed.
12. The Netfinity Advanced Systems Management Processor and Interconnect Bus integrated into Netfinity 5600 works with Netfinity Manager to provide significant system management
function. When used with optional Netfinity Advanced System Management PCI Adapter (P/N 01K7209) and Netfinity Advanced System Management Interconnect Cable Kit (P/N 03K9309)
additional management and control of up to 12 service processors from a remote console through a single modem or LAN connection is possible.
13. Includes PCI adapter, Netfinity Advanced System Management Interconnect Cable Kit components and 56-watt AC adapter which requires a separate power source. Provides an
integrated 10/100 Ethernet port and PCMCIA slot to support optional Netfinity Advanced System Management Token-Ring Connection (P/N 36L9654).
14. A maximum quantity of one is supported.
15. Required for all Netfinity servers containing a standard Advanced System Management Processor that are to be interconnected for system management support through a LAN or modem
connection (Netfinity 5500 models 8660- 1...4xU are not supported). Optional Netfinity Advanced System Management PCI Adapter (P/N 01K7209) includes the content of this option. Up to
12 service processors may be interconnected (including standard and optional processors) with an aggregate connection length of no more than 91.4 meters (300 ft.). A customer-supplied
Ethernet cable is required for each interconnection.
16. Contains an IBM Turbo 16/4 Token-Ring PCI Card, which installs in the PCMCIA card slot of Netfinity Advanced System Management PCI Adapter (P/N 01K7209), and a PC Card to 9-pin DShell cable which is routed to a rear chassis cut-out. The Netfinity Advanced System Management PCI Adapter integrated Ethernet port and Netfinity Advanced System Management TokenRing Connection cannot be connected or used together.
17. Provides an ESCON MIC and DB9 Serial Port. Cables are not included but are available through S/390 channels. Contact your IBM representative for additional information.
18. A maximum of two 9086001 adapters (installed in non-adjacent slots) are supported in a single Netfinity server.
Updated 01/01/00
For the latest product & technical information, refer to the Information Sources on pages 1 and 2.
63
Netfinity 5600 Power, Monitor & Accessories
Part Number
Description
Part Number
Power1
33L3760
Netfinity 250 W Hot-Swap Redundant Power Supply
Uninterruptable Power Supply
37L6858
Netfinity 5Ux24D Tower-to-Rack Kit6
Rack and NetBAY1
(UPS)2
94G3135
APC Smart-UPS 1000 (28 min. runtime at 245 Watts)
930842P
Netfinity Enterprise Rack
94G3136
APC Smart-UPS 1400 (43 min. runtime at 245 Watts)
930842X
Netfinity Enterprise Expansion Cabinet
94G6674
APC Smart-UPS 1400 RMB (34 min. runtime at 245
Watts)3
9306900
Netfinity Rack
94G6676
APC S3art-UPS 3000 RMB (84 min. runtime at 245
Watts)2
9306200
Netfinity NetBAY22
65464AN
G54 Color M5nitor 15” (13.7” Viewable Image Size),
stealth black4
28L3644
Space Saver II Keyboard3, 5
65474AN
G74 Color Monitor 17” (15.9” Viewable Image Size),
stealth black5
01K1260
TrackPoint IV 104-Key Black Keyboard4,5
65494AN
G96 Color Monitor 19” (17.9” Viewable Image Size),
stealth black7
28L3621
Preferred Keyboard (stealth black)4
9513AG1
T55A Flat Panel Color Monitor (15.0” Viewable Image
Size), stealth black6
28L3673
Sleek 2-Button Stealth Black Mouse
Monitors4
1. Netfinity 5600 includes two 250W hot-swap power supplies, each with its own
power cord. These standard power supplies are sufficient to operate fully configured
systems; however optional Netfinity 250W Hot-Swap Redundant Power Supply (P/N
33L3760) is required to preserve redundancy if any of the following are exceeded:
Single Processor Configuration
- Six SL hard disk drive (HDDs) and two PCI adapters
(1 HH HDD = 2 SL, 1 tape = 2 SL, 1 PCI adapter = 2 SL)
e.g. To preserve power supply redundancy with 3 PCI adapters only 4 SL HDDs
can be installed before an optional power supply is required.
Dual Processor Configuration
-Four SL hard disk drives (HDDs) and two PCI adapters
(1 HH HDD = 2 SL, 1 tape = 2 SL, 1 PCI adapter = 2 SL)
A “non-redundant” LED on the system unit will indicate when 250W has been
exceeded. Netfinity 250 W Hot-Swap Redundant Power Supply (P/N 33L3760)
includes a power cord which requires an additional power source. An independent
power source such as a second UPS or second circuit is not required.
2. Stated runtimes and power are for typical configurations (approximately 70% of
maximum capacity). For additional information see Appendix C: UPS Runtime
Estimate.
3. Height is 3U. See “Rack and NetBAY” for supported IBM racks.
4. Netfinity 5600 uses an SVGA controller (S3 Trio 3D chipset) with 4 MB of video
memory.
5. Installation within a rack requires optional Monitor Compartment (P/N 94G7444).
6. Installation within a rack requires optional Netfinity Flat Panel Monitor Rack Mount
Kit (P/N 37L6857) and Netfinity Rack Keyboard Tray (P/N 28L4707). A space saver
keyboard may coexist within the same 28L4707 keyboard tray.
7. Not supported for installation in a 19” rack.
64
Description
Conversion Kits
Keyboard and Mouse2
1. Netfinity 5600 rack models are housed in a 19” rack mountable drawer and require one of the
racks listed here. See IBM Netfinity Rack Cabinet and Options section for IBM rack supported
devices.
2. Tower models include both a mouse and a keyboard. Rack models include neither.
3. Installation within a rack requires optional keyboard tray P/N 28L4707 (stows in “ready-to-use”
position).
4. Installation within a rack requires optional keyboard tray P/N 28L4707. This keyboard cannot share
a keyboard tray with a flat panel display.
5. Advanced TrackPoint IV features are not available on IBM Netfinity systems.
6. Planned availability of 4Q 1999.
Tape Drives2
Part
Number
00N7991
20/40 GB DDS/4 4-mm Internal Tape Drive
Bays
Supported
SCSI
Interface
(bit)
Form Termination
Factor
Included
68/50-pin
Converter
Incl.
Ext. Tape
Enclosures1
A, B
16 Ultra2 LVD2
3.5” HH or
5.25” HH
Y3
N
3510020, 3551001
5.25” HH
N4
N
35100205,
3551001
3503B0X,
3551001
3503B0X5,
3551001
01K1325
20/40 GB 8-mm Internal SCSI Tape Drive
A, B
162
01K1320
20/40 GB DLT Internal SCSI Tape Drive
A/B6
82
5.25” FH
Y3
Y
00N7990
40/80 GB DLT Internal SCSI Tape Drive
A/B6
16 LVD2
5.25” FH
N4
N
-
16
External
Y
N
35O3B0X
3510020
-
8/16
16
16
16
Desktop
Rack
Desktop
N
Y
N
N
N
N
N
N
3551001
-
16
Desktop
Desktop or
Rack
Desktop
Desktop or
Rack
Y
-
-
Y
-
-
Y
-
-
Y
-
-
Associated Options
32G3918
SCSI-2 16-bit Active Terminator
External Tape Enclosures
3510020
3551001
10L7113
3503B0X
External Half High SCSI Storage Enclosure7
NetMEDIA Storage Expansion Unit EL8
NetMEDIA Systems Management Adapter9
DLT External SCSI Enclosure10
External Tape Libraries11
3502108
DLT Tape Autoloader
-
3502x14
DLT Tape Library
-
16
3503108
DLT8000 Tape Autoloader
-
16 LVD
3503x14
DLT8000 Tape Library
-
16 LVD
1. To determine cable requirements, note the tape drive’s SCSI interface, the appropriate SCSI controller from the system configurator section, and the desired enclosure, then refer to
Appendix D: Cables-Storage Units-Controllers.
2. Netfinity 5600 includes a wide two-drop terminated cable which is used for attachment of internal tape drives to a PCI Fast/Wide Ultra SCSI Adapter (P/N 02K3454) or, in the case where
the hot-swap backplane is attached to a RAID controller, it attaches to the onboard wide Ultra2 LVD controller. This cable does not support LVD mode of operation.
3. Tape drive is capable of self termination.
4. Termination is provided by the system unit’s standard SCSI cabling.
5. Requires SCSI-2 16-bit Active Terminator (P/N 32G3918).
6. Two half-high bays can be combined to support a full-high device.
7. Provides a black desktop 5.25” half-high (HH) tape enclosure. Connector is configurable as 50-pin Centronix or 68-pin high density. Requires either tape drive self termination or SCSI-2
16-bit Active Terminator (P/N 32G3918).
8. Provides a black 3U, 19” rack or NetBAY3 mountable tape enclosure. Provides two full high (FH) or four half high (HH) extended length 5.25” bays. External connector is 0.8-mm VHDCI.
Includes two power supplies and two power cords.
9. Installs in 3551001. Provides repeater function and LVDS interface allowing longer cable lengths and auto-termination when the 3551001 is powered off.
10. Provides a black desktop DLT tape enclosure with a 68-pin high density external connector. Requires termination by the tape drive or by installation of a SCSI-2 16-bit Active Terminator
(P/N 32G3918)
11. Tape library attributes and prerequisites are located in Appendix B: Tape Library Attributes.
NOTE: SCSI support for tape drives is provided by system unit onboard (standard) controller (no-RAID function) or PCI Fast Wide Ultra SCSI Adapter P/N 02K3454. Additional tape attributes
can be found in Appendix A: Tape Drive Attributes.
For a complete list of all IBM and non-IBM option compatibility with Network Operating Systems and IBM Netfinity Servers, access the ServerProven™ compatibility pages on the Web at URL
www.ibm.com/pc/us/compat.
Sample Configurations
Note: The following sample configurations are for illustration only and may not be suitable for any specific customer installation. Contact your IBM Business Partner
or IBM Marketing Representative for assistance with your specific configuration requirements.
High Availability Application Server
Part Number
8664-21Y
33L3060
36L9744
36L9749
01K1325
37L6086
33L3760
65464AN
94G3135
Description
Netfinity 5600 (Pentium III 600EB/512 128 MB Tower)
Netfinity 256 MB, 133 MHz SDRAM ECC RDIMM
Netfinity 9.1 GB Wide Ultra2 SCSI Hot-Swap SL HDD
Netfinity 18.2 GB 10K-3 Wide Ultra2 SCSI Hot-Swap SL HDD
20/40 GB 8-mm Internal SCSI Tape Drive
Netfinity ServeRAID-3HB Ultra2 SCSI Adapter
Netfinity 250 W Hot-Swap Redundant Power Supply
G54 Color Monitor 15” (13.7” Viewable Image Size), stealth black
APC Smart-UPS 1000
Quantity
Usage
1
1
2
4
1
1
1
1
1
384 MB total system memory
9.1 mirrored for NOS
36 GB RAID 5 with hot-spare
RAID 1 for OS, RAID 5 for data
Full power redundancy
UPS
This tower server is configured to act as the foundation for business critical applications, applications your business cannot afford to be without. Configured with
enough disk drives to mirror the operating system and provide a standard RAID 5 environment for data, optional hot-swap redundant power and UPS for power even
during a blackout, this server represents the leading edge in high availability. An internal tape drive is included to back up that all important asset...data. A modem
could be included to allow out-of-band (non-LAN) system management utilizing the integrated Netfinity Advanced System Management Processor.
Updated 01/01/00
For the latest product & technical information, refer to the Information Sources on pages 1 and 2.
65
IBM NETFINITY 5600
Netfinity 5600 Tape Options
High Availability File Server
Part Number
Quantity
Usage
8664-11Y
Netfinity 5600 (Pentium III 533EB/256 128 MB Tower)
Description
1
36L9744
Netfinity 9.1 GB Wide Ultra2 SCSI Hot-Swap SL HDD
6
45 GB available disk and
one hot spare
01K1325
37L6086
33L3760
65464AN
94G3135
20/40 GB 8-mm Internal SCSI Tape Drive
Netfinity ServeRAID-3HB Ultra2 SCSI Adapter
Netfinity 250 W Hot-Swap Redundant Power Supply
G54 Color Monitor 15” (13.7” Viewable Image Size), stealth black
APC Smart-UPS 1000
1
1
1
1
1
RAID 5 array, with hot-spare
Full power redundancy
-
This tower model is configured to meet the need of server consolidation. Many businesses are trying to get their arms around the dispersed departmental servers
that have grown up around the enterprise. By moving multiple servers onto one platform there is only one system to manage, both hardware and software. There is
potentially less expensive for service, software licenses, etc., and there is no need to worry about putting all your eggs in one basket because the Netfinity 5600 is
designed for high availability. This configuration includes 56 GB of internal HDD storage, features a third power supply which provides fully redundant power, a UPS
to help protect the system against a momentary electricity loss, and an internal tape drive that backs up, up to 40 GB per tape...in addition to all the standard
features of the Netfinity 5600.
66
IBM NETFINITY 5600
Updated 01/01/00
For the latest product & technical information, refer to the Information Sources on pages 1 and 2.
67
IBM Netfinity 7000 M10 Configurator
)
3
VD
or
s)
)
, L ail)
x)
ss
d)
an
D
a
r
e
I
F
v
ax
a
c
/M
M)
RA al/A
D,
d/M
ro
nd
t
d
,
D
a
M
P
t
d
t
S
2
t
)
H
t
ra (To
DI
(S
St
)
y(
s,
l, S
e n b p s U lt
e
=R
s
rs
tit
Hz
ot
na
r iv
(R
emt (M ual, Bay
an
Sl
o
(M sso B)
D
)
i
g
,
u
t
p
Q
ax
n a r ne ( D
er
ed oce
sk
(K
il)
ia
il)
(O
e
r
Di
pe
ow
va
M a h e le r
va
ed
ply
d/ M
or
ch
cy
E)
(P
rd
l/ A
r S of P
l/A
m Et trol le M
r
St
ct
up
a
n
D
(
a
a
o
e
a
p
e
a
I
S
t
a
C
t
d
t
s
(
r
F
b
y
r
lH
C
on
To
ys ar
wa
ab
nd
To
m
es
be
or
rm
we
OM
na
s(
m
s(
EC
. S bo I C mov
t-S
du
oc u m
Nu
-R
Fo
er
Po
ot
dv On CS
ay
Pr
l
N
Re
Ho
Me
rt
e
D
L2
nt
A
B
S
a
S
I
R
C
P
ax
./M
8680-6RY1
500
1/4
512
256 MB/8 GB
Rack (11U)
2/3
P, S,H,F
S-Fans,
S-Power4
Y
-
D,U
2/0
0/72.8 GB 32X-14X5
6/4
12/12
8680-7RY1
500
1/4
1024
256 MB/8 GB
Rack (11U)
2/3
P, S,H,F
S-Fans,
S-Power4
Y
-
D,U
2/0
0/72.8 GB 32X-14X5
6/4
12/12
8680-8RY1
500
1/4
2048
256 MB/8 GB
Rack (11U)
2/3
P, S,H,F
S-Fans,
S-Power4
Y
-
D,U
2/0
0/72.8 GB 32X-14X5
6/4
12/12
8680-1SY1
550
1/4
512
256 MB/8 GB
Rack (11U)
2/3
P, S,H,F
S-Fans,
S-Power4
Y
-
D,U
2/0
0/72.8 GB 40X-17X5
6/4
12/12
8680-2SY1
550
1/4
1024
256 MB/8 GB
Rack (11U)
2/3
P, S,H,F
S-Fans,
S-Power4
Y
-
D,U
2/0
0/72.8 GB 40X-17X5
6/4
12/12
8680-3SY1
550
1/4
2048
256 MB/8 GB
Rack (11U)
2/3
P, S,H,F
S-Fans,
S-Power4
Y
-
D,U
2/0
0/72.8 GB 40X-17X5
6/4
12/12
8680-11Y1, 6
550
1/4
512
512 MB/4 GB7
Rack (11U)
2/3
P, S,H,F
S-Fans,
S-Power4
Y
-
D,U
2/0
0/72.8 GB 40X-17X5
6/4
12/12
8680-21Y1, 6
550
1/4
1024
512 MB/4 GB7
Rack (11U)
2/3
P, S,H,F
S-Fans,
S-Power4
Y
-
D,U
2/0
0/72.8 GB 40X-17X5
6/4
12/12
1. Housed in a 19” Rack mountable drawer and ships standard without a keyboard or mouse. See “Rack and NetBAY” under “Netfinity 7000 M10 Power, Monitor & Accessories” for
supported IBM racks.
2. Intel Pentium III Xeon processor.
3. Netfinity 7000 M10 includes a systems management adapter equivalent to the one shipped with option 01K7209 (Netfinity Advanced System Management PCI Adapter).
4. Fully configured systems may require an optional 3rd power supply for redundancy. See footnote for Netfinity 400W Hot-Swap Redundant Supply II (P/N 01K7951) for
requirements.
5. Variable read rate. Actual playback speed will vary and is often less than the maximum possible.
6. These models include Advanced Chipkill memory, which provides a 100x imporvement over standard ECC memory by detecting and correcting both single and double 4-bit
memory errors.
7. The largest supported Chipkill memory expansion kit is 512 MB, which lowers the maximum “Chipkill” memory capacity to 4 GB.
Netfinity 7000 M10 Processor Upgrades
Part
Number
Processor Upgrades with 512 KB, 1 MB or 2 MB Cache SMP Support1
Processor Speed/Cache
Upgrade2
01K8006
Netfinity 7000 M10 400 MHz, 512 KB Upgrade with Pentium II Xeon Processor
1RU
-
01K8007
Netfinity 7000 M10 400 MHz, 1 MB Upgrade with Pentium II Xeon Processor
2RU
All 1RU
10L5895
Netfinity 7000 M10 450 MHz, 512 KB Upgrade with Pentium II Xeon Processor
3RU
All 1...2RU
10L5896
Netfinity 7000 M10 450 MHz, 1 MB Upgrade with Pentium II Xeon Processor
4RU
All 1...3RU
10L5897
Netfinity 7000 M10 450 MHz, 2 MB Upgrade with Pentium II Xeon Processor
5RU
All 1...4RU
28L4733
Netfinity 7000 M10 500 MHz/512 KB Upgrade with Pentium III Xeon Processor
6RY
All 1...5RU
28L4734
Netfinity 7000 M10 500 MHz/1 MB Upgrade with Pentium III Xeon Processor
7RY
All 1...6Rx
28L4735
Netfinity 7000 M10 500 MHz/2 MB Upgrade with Pentium III Xeon Processor
8RY
All 1...7Rx
33L5107
Netfinity 550 MHz /512 KB Upgrade with Pentium III Xeon Processor
1xY
All xRx
33L5108
Netfinity 550 MHz /1 MB Upgrade with Pentium III Xeon Processor
2xY
All xRx, 1xY
33L5109
Netfinity 550 MHz /2 MB Upgrade with Pentium III Xeon Processor
3SY
All xRx, All 1...2xY
1. Up to three additional processors may be installed, providing a maximum of four. All processors must be identical in type, speed, and cache size.
2. Requires removal of the standard processor. A maximum of four processors may be installed. All processors must be identical in type, speed and cache size. Upgrades may require
a BIOS update. To obtain the latest Flash BIOS, access www.ibm.com/pc/support and enter machine “Type-Model” in Quick Path. Se lect “Downloadable files” and then “BIOS”.
68
Netfinity 7000 M10 Memory
Model 1RU
All Models (except 1RU and x1Y))
128 MB
256 MB
384 MB
512 MB
640 MB
768 MB
896 MB
1024 MB
1408 MB
1536 MB
2048 MB
3072 MB
4096 MB
5120 MB
6148 MB
8 GB (max)
4 x 32MB DIMMs Std.
1 x 01K8044
1 x 01K8045
3 x 01K8044
1 x 01K8044, 2 x 01K8045
4 x 01K80453, 4
2 x 01K8045, 2 x 01K80462, 4
4 x 01K8045, 2 x 01K8046, 1 x 01K80042, 4
4 x 01K8044, 4 x 01K8046, 1 x 01K80045, 6
4 x 01K8045, 4 x 01K8046, 1 x 01K80045, 6
8 x 01K8046, 1 x 01K80045, 6
4 x 64MB DIMMs Std.
1 x 01K80442
1 x 01K8045
3 x 01K80443
1 x 01K8044, 2 x 01K80452
4 x 01K80453, 4
2 x 01K8045, 2 x 01K80462, 4
4 x 01K8045, 2 x 01K8046, 1 x 01K80042, 4
3 x 01K8044, 4 x 01K8046, 1 x 01K80045, 6
4 x 01K8045, 4 x 01K8046, 1 x 01K80045, 6
8 x 01K8046, 1 x 01K80045, 6
Chipkill Models x1Y
4 x 128 MB DIMMs Standard
1 x 28L47322
2 x 28L47322
3 x 28L47323
5 x 28L4732, 1 x 01K80045
7 x 28L4732, 1 x 01K80045
-
This table does not represent all possible memory configurations.
NOTE: 8-way interleaving can be obtained by installing identical memory in one or more of the following adjacent bank pairs: 1/2, 3/4, 5/6, 7/8 or by installing memory in both the standard and
optional (P/N 01K8004) memory cards, both being identically configured. Greater than 8-way interleaving can be obtained by combining both 8-way interleaving methods (adjacent banks and
identical memory cards). Netfinity 7000 M10 will recognize optimized configurations at boot-up and enable appropriate interleaving.
1. Network Operating Systems may limit the maximum amount of addressable memory. See operating system specifications for further information.
2. Can be configured for 8-way interleaving.
3. Can be configured for 8-way interleaving or greater than 8-way with Netfinity 7000 M10 Memory Expansion Card (P/N 01K8004).
4. Assumes removal of standard memory DIMMs.
5. Can be configured for greater than 8-way interleaving.
6. Requires removal of standard memory DIMMs.
Part Number
Memory Description1
01K8044
Netfinity 7000 M10 256 MB Memory Expansion Kit - 4 x 642
01K8045
Netfinity 7000 M10 512 MB Memory Expansion Kit - 4 x 1282
28L4732
Netfinity 7000 M10 512 MB Advanced Memory Expansion Kit (Chipkill) - 4 x 1282, 3
01K8046
Netfinity 7000 M10 1 GB Memory Expansion Kit - 4 x 2562
01K8004
Netfinity 7000 M10 Memory Expansion Card4
1. Memory is four-way interleaved 50 ns, EDO, ECC, 168-pin DIMMs. Properly configured memory options allow eight-way or
greater interleaving
2. DIMM size must be consistent within a Bank. DIMM sizes may vary from Bank to Bank.
3. Advanced ECC DIMMs not only detect and correct single 4-bit memory errors, but detect and correct two 4-bit errors as
well. These advanced memory DIMMs significantly improve reliability up to 100 times over current ECC technology. In order
to provide this increased reliability for all installed memory, co-existience with other Netfinity 7000 M10 memory is not
recommended.
4. Required for installation of DIMMs in Banks 5...8.
Updated 01/01/00
Standard Memory Card A Optional Memory Card B
Bank 4
Bank 3
Bank 2
Bank 1
Bank 8
Bank 7
Bank 6
Std. DIMM Bank 5
Bank 4
Bank 3
Bank 2
Bank 1
Bank 8
Bank 7
Bank 6
Std. DIMM Bank 5
Bank 4
Bank 3
Bank 2
Bank 1
Bank 8
Bank 7
Bank 6
Std. DIMM Bank 5
Bank 4
Bank 3
Bank 2
Bank 1
Bank 8
Bank 7
Bank 6
Std. DIMM Bank 5
For the latest product & technical information, refer to the Information Sources on pages 1 and 2.
69
IBM NETFINITY 7000 M10
Total Memory1
Netfinity 7000 M10 Hard Disk Drive (HDD) Storage
Total Internal
Storage1
7200 RPM Hard Disk Drives
(HDDs)
9.1 GB
0 GB
18.2 GB
10,000 RPM HDDs
36.4 GB
9.1 GB
Standard on Base Models
9.1 GB
1 x 01K8053
-
18.2 GB
2 x 01K8053 or 1 x 02K0440
27.2 GB
3 x 01K8053
36.4 GB
4 x 01K8053 or 2 x 02K0440 or
1 x 36L9806
2 x 36L9806 or
-
54.6 GB
-
3 x 02K0440
72.8 GB (max)
-
4 x 02K0440 or
18.2 GB
36.4 GB
Standard on Base Models
-
-
1 x 36L9807
3 x 36L9806
1 x 02K0441 4 x 36L9806 or
-
-
2 x 36L9807 or
1 x 36L9808
-
-
3 x 36L9807
2 x 02K0441
-
4 x 36L9807 or
2 x 36L9808
This table does not represent all possible hard drive configurations.
1. Total Internal Storage listed is within + 0.2 GB unless otherwise noted.
Bay
Form
Factor
Height
Front
Access
Usage
-
3.5”
SL
Yes
Diskette
-
5.25”
HH
Yes
IDE CD-ROM
Part
Number
Description
RPM
Height
Bays
Max
Supported Qty.
Internal Hard Disk Drives
(HDD)
01K8053
Netfinity 9.1GB Wide Ultra SCSI
SCA-2 SL HDD
7200
SL
1...4
4
7200
SL
1...4
4
1...4
HS
SL1
Yes
Open
02K0440
Netfinity 18.2 GB Wide Ultra SCSI
Hot-Swap SL HDD
NB32
19” Rack
3U
Yes
Open
02K0441
Netfinity 36.4 GB Wide Ultra SCSI
Hot-Swap HDD
7200
HH1
1/2, 3/4
2
36L9806
Netfinity 9.1 GB 10K-3 Wide Ultra
SCSI Hot-Swap SL HDD
10,000
SL
1...4
4
36L9807
Netfinity 18.2 GB 10K-3 Wide Ultra
SCSI Hot-Swap SL HDD
10,000
SL
1...4
4
36L9808
Netfinity 36.4 GB 10K-3 Wide Ultra
SCSI Hot-Swap HDD
10,000
HH1
1/2, 3/4
2
1. Two slim-line (SL) bays can be combined to support a single half-high
device.
2. A total of three optional 3U NetBAY3s can be stacked beneath a
Netfinity 7000 M10 which has Netfinity 7000 M10 Rack-to-Tower
Conversion Kit installed. See IBM Netfinity NetBAY3 Stackable Enclosure
section for supported devices
External Storage Expansion
Units2
Form Factor
35202RU
Netfinity EXP15 Storage Expansion
Unit
Rack (3U)
Hot-Swap (HS)
Removable
Bay 1
35301RU
Netfinity EXP200 Storage
Expansion Unit
Rack (3U
Bay 2
Bay 3
Bay 4
37L5857
Netfinity EXP200 Rack-to-Tower
Conversion Kit
Media (RM)
Diskette
IDE CD-ROM
Tower
1. Two slim-line (SL) bays can be combined to support a single half-high (HH) device.
2. Not supported by the onboard external SCSI port. Select an optional SCSI controller then refer to see
Appendix D: Cables-Storage Units-Controllers to confirm the controller supports the desired External Storage
Expansion Unit and to select a supported cable. For HDD or other expansion unit options, see the specific
expansion unit section.
Netfinity NetBAY3 (NB3)
(Optional)
(Requires Rack to
Tower Kit)
Internal SCSI Cabling
Netfinity 7000 M10 systems contain a backplane supporting four hot-swap drive bays. The backplane is connected to one of the two onboard Ultra SCSI controllers
through a 16-bit SCSI cable. If a RAID adapter or other supported SCSI adapter is installed for attachment to the internal hard disk drives, the 16-bit SCSI backplane
cable is moved from the standard Ultra SCSI controller to the desired controller. The onboard external SCSI port contains a 0.8mm Very High Density Connection
Interface (VHDCI) connector and can be used to attach up to 15 SCSI devices with the appropriate SCSI cable.
70
Netfinity 7000 M10 I/O Options
Part
Number
Description
Adapter
PCI
Slots
HotLength Support Supported1 Plug2
Storage Controllers3
01K7364
Netfinity ServeRAID-3L Ultra2 SCSI Adapter4,5
Full
32-bit
1...126
X
37L6086
Netfinity ServeRAID 3-HB Ultra2 SCSI Adapter7
Full
32/64-bit
1...126
X
02K3454
PCI Fast/Wide Ultra SCSI Adapter
Half
32-bit
1...12
-
01K7297
Netfinity Fibre Channel PCI Adapter8
Half
32/64-bit
1...12
-
9
-
09L2123
Advanced SerialRAID/X Adapter
Full
32-bit
1...12
Full Length Adapter Slots /
Power Supply Bays
1...12
-
1...12
X
33L4618
PCI V.90 56 Data/Fax Modem11
Half
32-bit
1...12
-
37L1414
Serial I/O SST8P DB Adapter12
Half
32-bit
1...1212
-
37L1415
Serial I/O SST16P RJ Adapter12
Half
32-bit
1...1212
-
37L1423
Serial I/O SST16P DB Adapter12
Half
32-bit
1...1212
-
37L1416
Serial I/O SST128P Expandable Adapter12
Half
32-bit
1...1212
-
Communications
Systems Management13
03K9309
Netfinity Advanced System Management
Interconnect Cable Kit14
-
-
-
-
36L9654
Netfinity Advanced System Management TokenRing Connection15
-
-
-
-
Full
32-bit
1...1218
-
Adapter16
02K6545
UltraSlim 56W AC
9086001
Netfinity ESCON Adapter17
Host Attach
1. PCI Slots 1...5 support 64-bit or 32-bit operations. PCI Slots 6...12 support 32-bit operations.
2. All 12 PCI slots are Hot Plug capable using IBM’s Active PCI Technology. For Network Operating System support access URL www.ibm.com/pc/us/compat.
3. Netfinity 7000 M10 includes two onboard Wide Ultra SCSI controllers, one internal connector and one external port with a 0.8 mm Very High Density Connection Interface (VHDCI), which
can be used to attach up to 15 SCSI devices with the appropriate SCSI cable.
4. All ServerRAID-3x adapters can be upgraded with the same enhanced software utilities and firmware included with ServeRAID-3HB. The download is available for no charge from
www.ibm.com/pc/support. select “Server” in Brand pulldown, “ServeRAID” in the Family pulldown and then “Downloadable files”. The upgrade should be considered for installations with
firmware less than Version 3.5.
5. Netfinity ServeRAID-3L Ultra2 SCSI Adapter (P/N 01K7364) provides either one internal or one external (0.8 mmVHDCI) LVDS SCSI channel.
6. A total quantity of eight, in any combination of 01K7364, 37L6086 and 01K7207 is supported.
7. Netfinity ServeRAID-3HB Ultra2 SCSI Adapter (P/N 37L6086) provides one internal and two external (0.8 mm VHDCI) LVDS SCSI channels. The internal channel can be configured for
external usage (0.8 mm VHDCI) providing a total of three external LVDS SCSI channels. Includes 32 MB of mirrored battery-backu p cache, which helps protect against data loss in writeback cache mode in the event of a power outage or adapter maintenance.
8. See Netfinity Fibre Channel Solutions section for additional configuration information.
9. A maximum quantity of four is supported.
10. Netfinity 7000 M10 does not include an onboard network controller.
11. Due to homologation variances, modem availability may differ by country.
12. See Appendix E for details on Serial I/O options and configuration limitations. A maximum of four Serial I/O adapters (any combination of P/N 37L1414, 37L1415, 37L1416, 37L1423) may be
installed.
13. Netfinity 7000 M10 ships standard with a Netfinity Advanced System Management PCI Adapter. Unlike optional Netfinity Advanced System Management PCI Adapter (P/N 01K7209), a
56-watt AC adapter and interconnect cable are NOT included and must be ordered separately if desired.
14. Required for all Netfinity Servers containing a standard Advanced System Management Processor that are to be interconnected for system management support through a LAN or
modem connection (Netfinity 5500 models 8660 1...4xU are not supported). Up to 12 service processors may be interconnected (including standard and optional processors) with an
aggregate connection length of no more than 91.4 meters (300 ft.). A customer-supplied Ethernet cable is required for each interconnection.
15. Contains an IBM Turbo 16/4 Token-Ring PCI Card, which installs in the PCMCIA card slot of Netfinity Advanced System Management PCI Adapter and a PC Card to 9-pin D-Shell cable
which is routed to a rear chassis cut-out. The Netfinity Advanced System Management PCI Adapter’s integrated Ethernet port and Netfinity Advanced System Management Token-Ring
Connection cannot be connected or used together. The firmware level of the integrated Netfinity Advanced System Management PCI Adapter must be at level 32A or later. To download the
latest firmware, access URL www.ibm.com/pc/us/netfinity. Select “Server Support”, “Family”, “Model”, “Downloadable Files” and finally “Advanced Sytem Management”.
16. Although the 7000 M10 integrated Netfinity Advanced System Management PCI Adapter is powered continuously through the redundant power supply subsystem, an even higher level of
availability is offered with the addition of UltraSlim 56W AC Adapter by allowing an independent power source or connection to a separate optional UPS.
17. Provides an ESCON MIC and DB9 Serial Port. Cables are not included but are available through S/390 channels. Contact your IBM representative for additional information.
18. A maximum of two 9086001 adapters (installed in non-adjacent slots) are supported in a single Netfinity server.
Updated 01/01/00
For the latest product & technical information, refer to the Information Sources on pages 1 and 2.
71
IBM NETFINITY 7000 M10
32-bit
32-bit
Slot 12- PCI, Hot-Plug, 32-bit, Full Length
Half
Half
Slot 11- PCI, Hot-Plug, 32-bit, Full Length
Token-Ring 100/16/4 High-Speed PCI Adapter
Token-Ring 16/4 PCI Adapter 2
Slot 10- PCI, Hot-Plug, 32-bit, Full Length
34L0501
34L0601
Slot 9- PCI, Hot-Plug, 32-bit, Full Length
X
Optional
400 W Hot-Swap
Redundant Power
Supply II
(P/N 01K7951)
1...12
Slot 8- PCI, Hot-Plug, 32-bit, Full Length
32/64-bit
Slot 7- PCI, Hot-Plug, 32-bit, Full Length
Half
Token Ring
Optional on 8680-1RU
(P/N 01K7951)
Netfinity Gigabit Ethernet SX Adapter
34L0301
Slot 6- PCI, Hot-Plug, 32-bit, Full Length
X
Slot 5- PCI, Hot-Plug, 32/64-bit, Full Length
X
1...12
Slot 4- PCI, Hot-Plug, 32/64-bit, Full Length
1...12
32-bit
Standard on all but
8680-1RU
400 W Hot-Swap
Power Supply
32-bit
Half
Slot 3- PCI, Hot-Plug, 32/64-bit, Full Length
Half
Netfinity 10/100 Fault Tolerant Adapter
Slot 2- PCI, Hot-Plug, 32/64-bit, Full Length
Netfinity 10/100 Ethernet PCI Adapter 2
08L3341
Standard on all
models
400 W Hot-Swap
Power Supply
Ethernet
34L1501
Slot 1- PCI, Hot-Plug, 32/64-bit, Full Length
Networking10
Netfinity 7000 M10 Power, Monitor & Accessories
Part
Number
Description
Part
Number
Power1
01K7951
Netfinity 400W Hot-Swap Redundant Power Supply II2
01K7952
Netfinity 7000 M10 Dual Cord Power Unit3
Uninterruptible Power Supply (UPS)4
Conversion Kits
01K8005
Netfinity 7000 M10 Rack-to-Tower Conversion Kit1
930842P
Netfinity Enterprise Rack
Rack and NetBAY2
94G6674
APC Smart-UPS 1400RMB (12 min. runtime at 525 Watts)5
930842X
Netfinity Enterprise Extension Cabinet
94G6676
APC Smart-UPS 3000RMB (35 min. runtime at 525 Watts)5
9306900
Netfinity Rack
65464AN
G54 Color Monitor 15” (13.7” Viewable Image Size), stealth black6
Monitors
9306200
Netfinity NetBAY22
10L6912
Netfinity NeyBAY33
Keyboard and Mouse4
65474AN
G74 Color Monitor 17” (15.9 Viewable Image Size), stealth black6
65494AN
G96 Color Monitor 19” (17.9” Viewable Image Size), stealth black7
28L3644
Space Saver II Keyboard5,7
9513AG1
T55A Flat Panel Color Monitor (15.0” Viewable Image Size),
stealth black8
01K1260
TrackPoint IV 104-Key Black Keyboard6,7
28L3621
Preferred Keyboard (stealth black)6
28L3673
Sleek 2-Button Stealth Black Mouse
1. Netfinity 7000 M10 systems containing a single power supply (8680-1RU) do not provide
power supply redundancy and require optional power supply 01K7951 when configurations
contain one or more of the following:
- Netfinity 7000 M10 Memory Expansion Card (P/N 01K8004)
- Three processors
- Six PCI adapters
Netfinity 7000 M10 systems containing two power supplies (standard on all models except
8680-1RU) provide power supply redundancy and only require optional power supply
01K7951 when redundancy is required for configurations containing one or more of the
following:
- Netfinity 7000 M10 Memory Expansion Card (P/N 01K8004)
- Three processors
- Six PCI adapters
2. Includes a power cord which is not used. No additional power source is required.
3. Provides power cord redundancy for the Netfinity 7000 M10. A second power source is
required. Even though a second UPS may provide a redundant power source, systems
management software does not currently take advantage of its power outage alerts.
4. Stated runtimes and power are for typical configurations (approximately 70% of maximum
capacity). For additional information, see Appendix C: UPS Runtime Estimate.
5. Height is 3U. See “Rack and NetBAY” for supported IBM racks.
6. Installation within a rack requires optional Monitor Compartment (P/N 94G7444).
7. Not supported for installation in a 19” rack.
8. Installation within a rack requires optional Netfinity Flat Panel Monitor Rack Mount Kit (P/N
37L6857) and Netfinity Rack Keyboard Tray (P/N 28L4707). A space saver keyboard may
coexist within the same 28L4707 keyboard tray.
72
Description
1. Includes casters, which can also be used with NetBAY3.
2. Netfinity 7000 Mxx rack models are housed in a 19” rack mountable drawer and require
one of the racks listed here. See “IBM Netfinity Rack Cabinet and Options” section for IBM
rack supported devices.
3. A maximum of three NetBAY3 enclosures may be stacked beneath a supported
Netfinity tower server (conversion kit 01K8005 required). See IBM Netfinity NetBAY3
Stackable Enclosure section for supported devices.
4.Netfinity 700 M10 ships without a keyboard or mouse.
5. Installation within a rack requires optional keyboard tray P/N 28L4707 (stows in “readyto-use” position).
6. Installation within a rack requires optional keyboard tray P/N 28L4707. This keyboard
cannot share a keyboard tray with a flat panel display.
7. Advanced TrackPoint IV features are not available on IBM Netfinity systems.
.
Netfinity 7000 M10 Tape Options
Part
Number
Description
Bays
SCSI
Form Factor
Supported Interface
(bit)
Termination 68/50-pin Ext. Tape
Included
Converter
Encl.1
Incl.
01K1282
12/24 GB DDS/3 4-mm Internal Tape Drive
N/A2
8
3.5”HH or 5.25”HH
Y6
Y
01K1319
10/20 GB NS Internal SCSI Tape Drive
N/A2
8
3.5”SL or 5.25”HH
Y6
Y
01K1325
20/40 GB 8-mm Internal SCSI Tape Drive
N/A2
16
5.25”HH
N
N
01K1320
20/40 GB DLT Internal SCSI Tape Drive
N/A2
8
5.25”FH
Y6
Y
04K0149
35/70 GB DLT Internal SCSI Tape Drive
N/A2
16
5.25”FH
N
N
00N7990
40/80 GB DLT Internal SCSI Tape Drive
N/A2
16 LVD
5.25” FH‘
N
N
32G3918
SCSI-2 16-bit Active Terminator
-
16
External
Y
N
3510020,
3503B0X
3510020
3551001
10L7113
3503BOX
External Half High SCSI Storage Enclosure5
NetMEDIA Storage Expansion Unit EL6
NetMEDIA Systems Management Adapter7
DLT External SCSI Enclosure8
-
8/16
16
16
16
Desktop
Rack
Desktop
N
Y
N
N
N
N
N
N
3551001
-
3502108
3502x14
3503108
3503X14
DLT Tape Autoloader
DLT Tape Library
DLT8000 Tape Autoloader
DLT8000 Tape Library
Magstar MP 3570 Tape Subsystem (models
B2x and C2x)
-
16
16
16 LVD
16 LVD
Desktop
Desktop or Rack
Desktop
Desktop or Rack
Y
Y
Y
Y
-
-
-
Differential
Rack
Y
-
-
3510020
3510020,
3551001
35100204
3551001
3503B0X,
3551001
3503B0X4,
3551001
3503B0X4,
3551001
IBM NETFINITY 7000 M10
Associated Options
External Tape Enclosures
External Tape Libraries9
3570xxx
1. To determine cable requirements, note the tape drive’s SCSI interface, the appropriate SCSI controller from the system configurator section and the desired enclosure, then refer to
Appendix D: Cables - Storage Units - Controllers.
2. Netfinity 7000 M10 supports tape drives installed in external enclosures only. See External Tape Enclosure column.
3. Tape drive is capable of self termination.
Provides a black desktop 5.25” half-high (HH) tape enclosure. Connector is configurable as 50-pin Centronix or 68-pin high density. Requires either tape drive self-termination or SCSI-2 16bit Active Terminator (P/N 32G3918).
4. Requires SCSI-2 16-bit Active Terminator (P/N 32G3918).
5. Provides a black desktop DLT tape enclosure. External connector is 68-pin high density. Requires SCSI-2 16-bit Active Terminator (P/N 32G3918).
6. Provides a black 3U, LVDS, 19” rack or NetBAY3 mountable tape enclosure. Provides two full high (FH) or four half high (HH) extended length 5.25” bays. External connector is 0.8mm
VHDCI. Includes two power supplies and two power cords.
7. Installs in 3551001. Provides repeater function and LVDS interface allowing longer cable lengths and auto-termination when the 3551001 is powered off.
8. Provides a black desktop DLT tape enclosure with a 68-pin high density external connector. Requires termination by the tape drive or by installation of a SCSI-2 16-bit Active Terminator
(P/N 32G3918).
9. Tape library attributes and prerequisites are located in Appendix B: Tape Library Attributes.
NOTE: SCSI support for tape drives is provided by system unit onboard (standard) controller (no-RAID function) or PCI Fast Wide Ultra SCSI Adapter P/N 02K3454. Additional tape attributes
can be found in Appendix A: Tape Drive Attributes.
Updated 01/01/00
For the latest product & technical information, refer to the Information Sources on pages 1 and 2.
73
Sample Configurations
The following sample configurations are for illustration only and may not be suitable for any specific customer installation. Contact your IBM Business Partner or IBM
Marketing Representative for assistance with your specific configuration requirements.
High Availability-Rack
Part Number
Quantity
Usage
8680-7RY
Netfinity 7000 M10 (PIII Xeon 500-1 MB/256 MB/Rack)
Description
1
Power Redundancy standard
28L4734
Netfinity 7000 M10 500 MHz/1 MB Upgrade with Pentium III Xeon Processor
1
Total SMP processors: Two
28L4732
Netfinity 7000 M10 512 MB Advanced Memory Expansion Kit- 4x128
1
Total: 512 MB1
01K8053
Netfinity 9.1 GB Wide Ultra SCSI SCA-2 SL HDD
4
-
34L1501
Netfinity 10/100 Ethernet PCI Adapter 2
1
37L6086
Netfinity ServeRAID-3HB Ultra2 SCSI Adapter
1
65464AN
G54 Color Monitor 15” (13.7” Viewable Image Size), stealth black
1
RAID Controller
-
28L3644
Space Saver II Keyboard
1
Includes TrackPoint
94G6676
APC Smart-UPS 3000RMB
1
External Tape Drive Enclosure
External Storage
3551001
NetMEDIA Storage Expansion Unit EL
1
00N7990
40/80 GB DLT Internal SCSI Tape Drive
2
Installs in 3551001
35202RU
Netfinity EXP15
1
Provides additional 10 bays
03K9310
Netfinity 2M Ultra2 SCSI Cable
2
EXP15 to ServeRAID-3HB, Tape to Onboard
36L9809
Netfinity EXP 9.1 GB 10K-3 Wide Ultra SCSI Hot-Swap HDD
6
RAID 5 with Hot-Spare in EXP15.
Rack Options
9306200
Netfinity NetBAY22
1
Monitor and Keyboard mount on top
94G6670
Blank Filler Panel Kit
1
-
1. Advanced ECC DIMMs not only detect and correct single 4-bit memory errors but detect and correct two 4-bit errors as well. These advanced memory DIMMs significantly improve
reliability up to 100 times over current ECC technology. In order to provide this increased reliability for all installed memory, co-existence with other Netfinity 7000 M10 memory is not
recommended and has therefore been removed in this sample configuration.
This high availability server is configured to act as the foundation for business critical applications, applications your business cannot afford to be without. The
configuration includes enough disk drives to mirror the operating system and provide a RAID 5 data environment, power supply redundancy by the server and
EXP15 and a UPS for power even during a blackout. A rack mounted tape drive is included to back-up that all important asset......data. This server represents the
leading edge in high availability.
Notes/Exchange-Stack
Part Number
Description
Quantity
Usage
8680-2SY
Netfinity 7000 M10 (PIII Xeon 550-1 MB/256 MB/Rack)
1
-
33L5108
Netfinity 550 MHz/ 1 MB Upgrade with Pentium III Xeon Processor
3
Total SMP processors: Four
01K8045
7000 M10 512 MB Memory Expansion Kit - 4x128
2
Total: 3GB1, 8-way interleaved
01K8046
Netfinity 7000 M10 1 GB Memory Expansion Kit - 4x256
2
Total: 3GB1, 8-way interleaved
01K8004
Netfinity 7000 M10 Memory Expansion Card
1
Enables 8-way intleaving configuration
36L9806
Netfinity 9.1 GB 10K-3 Wide Ultra SCSI Hot-Swap SL HDD
2
NOS Mirroring
34L1501
Netfinity 10/100 Ethernet PCI Adapter 2
2
-
37L6086
Netfinity ServeRAID-3HB Ultra2 SCSI Adapter
1
RAID Controller
65464AN
G54 Color Monitor 15” (13.7” Viewable Image Size), stealth black
1
-
28L3644
Space Saver II Keyboard
1
Includes TrackPoint
01K7951
Netfinity 400W Hot-Swap Redundant Power Supply II
1
Required to preserve power redundancy
94G6676
APC Smart-UPS 3000RMB
1
External Tape Drive Enclosure
External Storage
3551001
NetMEDIA Storage Expansion Unit EL
1
00N7990
40/80 GB DLT Internal SCSI Tape Drive
2
Installs in 3551001
35202RU
Netfinity EXP15
1
Provides additional 10 bays
03K9310
Netfinity 2M Ultra2 SCSI Cable
2
EXP15 to ServeRAID-3H, Tape to System
36L9810
Netfinity EXP 18.2 GB 10K-3 Wide Ultra SCSI Hot-Swap HDD
10
RAID 5 with Hot-Spare in EXP15
Stack Options
01K8005
Netfinity 7000 M10 Rack-to-Tower Conversion Kit
1
Monitor and Keyboard mount on top
10L6912
Netfinity NetBAY3
3
Provides space for EXP15, UPS and Tape
1. Configuration for 8-way interleaving with Netfinity 7000 M10 Memory Expansion Card (P/N 01K8004) requires removal of standard memory.
74
Two Node High Availability Cluster
Public
LAN
Server Node A
ServeRAID-3HB
(37L6086)
CH3
CH2
CH1
10/100 Ethernet (34L1501)
10/100 Ethernet (34L1501)
(03K9311)
(25’ Ethernet
Crossover Cable1)
Netfinity EXP 15
Server Node B
CH3
CH2
CH1
10/100 Ethernet (34L1501)
ServeRAID-3HB
(37L6086)
10/100 Ethernet (34L1501)
Public
LAN
Part Number
Two Node High Availability Cluster
Description
Server Nodes A & B
8680-3SY
33L5109
01K8044
01K8046
01K8004
01K7364
01K8053
34L1501
37L6086
01K7951
94G6676
Netfinity 7000 M10 (PIII Xeon 550-2 MB/256 MB/Rack) (11U)
Netfinity 550 MHz/2 MB Upgrade with Pentium III Xeon Processor
Netfinity 7000 M10 256 MB Memory Expansion Kit
Netfinity 7000 M10 512 MB Memory Expansion Kit
Netfinity 7000 M10 Memory Expansion Card
Netfinity ServeRAID-3L Ultra2 SCSI Adapter
Netfinity 9.1 GB Wide Ultra SCSI SCA-2 SL HDD
Netfinity 10/100 Ethernet PCI Adapter 21
Netfinity ServeRAID-3HB Ultra2 SCSI Adapter2
Netfinity 400W Hot-Swap Redundant Power Supply II
APC Smart-UPS 3000RMB (3U)
3551001
03K9310
00N7990
35202RU
36L9810
03K9311
NetMEDIA Storage Expansion Unit EL (3U)
Netfinity 2M Ultra2 SCSI Cable3
40/80 GB DLT Internal SCSI Tape Drive
Netfinity EXP15 (3U)2
Netfinity EXP 18.2 GB 10K-3 Wide Ultra SCSI Hot-Swap HDD
Netfinity 4.2 M Ultra2 SCSI Cable2, 3
9513AG1
28L3644
T55A Flat Panel Color Monitor (15.0” Viewable Image Size), stealth black
Space Saver II Keyboard
9306900
37L6857
28L4707
28L0542
94G6667
94G7447
94G6669
94G6670
9306-900 Netfinity Rack
Netfinity Flat Panel Monitor Rack-Mount Kit (3U)
Netfinity Rack Keyboard Tray
Netfinity Console Server Selector Switch (4-port)
Power Cable-Type A143
12 ft Console Cable Set
Side Panel Kit
Blank Filler Panel Kit
Quantity
Usage
2
6
2
4
2
2
4
4
2
2
2
Total SMP processors: 4 each
Total: 1.5 GB, 8-way interleave capable
Optimizes 8-way interleaving
1 per node for NOS HDDs
NOS on Mirrored HDDs
1 Private Interconnect, 1 public
Three channels for EXP15s
Required to preserve power redundancy
Provides redundant power sources
1
1
2
1
10
2
External Tape Drive Enclosure
Attaches 3551001 to onboard SCSI
Installs in 3551001
RAID 5 Shared Storage
Attach EXP15 to ServeRAID-3HBs
1
1
Mounts in keyboard tray
Includes TrackPoint
External Storage
Shared (or single occurrence) Resources
Industry Standard 19” Rack, EIA-310D, Min. depth of 29.23”
1
1
1
1
5
2
1
1
Mounts in keyboard tray
-
1. Requires customer supplied Ethernet Crossover Cable which may vary in length up to a maximum of 25’ (7.6 m).
2. By replicating these items, up to a total quantity of four ServeRAID-3HB Adapters (plus options) and eleven EXP15s can provide over 2 Terabytes of storage. Additional power and rack
space will be required.
3. Cable length requirements are dependent on component placement within the rack or rack suite. To determine specific configuration requirements use the Netfinity Rack Configurator
which is downloadable from Web site www.ibm.com/pc/us/netfinity/tech_library.html “Configuration Tools”.
Clustering is a group of interconnected computers used as a single, unified computing resource. Clustering Netfinity servers, like the IBM Netfinity 7000 M10, provides a high availability solution
to keep you in touch with the key applications you need to run your business.
This sample configuration consists of paired IBM Netfinity 7000 M10 cluster nodes equipped with four-way SMP capability and redundant power supplies. Microsoft Cluster Service (MSCS) has
been validated IBM Netfinity 7000 M10 servers, using the Netfinity ServeRAID-3HB with the EXP15 Storage Expansion Unit. MSCS allows two configured servers, referred to as nodes, to be
connected together to form a cluster. Providing system redundancy means that a complete server can fail and client access to server resources is largely unaffected. MSCS extends this theme
by also allowing for software failures at an application level as well as an operating system level. If the operating system fails, all applications and services can be restarted on another server,
and if just one application fails, it can be managed by MSCS individually. An additional independent network connection is used to perform monitoring within the cluster. One or more disk
subsystems are attached to both nodes. In the above example, a Netfinity EXP15 was selected and the Netfinity ServeRAID-3HB Ultra2 SCSI Adapters provide the I/O control. Netfinity
ServeRAID-3HB handles the “SCSI heartbeat” connection without the need for a dedicated SCSI connection and logically attaches t he quorum disk, which allows arbitration when a failure
occurs. Additional information on IBM Netfinity and IBM PC Server Clustering Solutions may be found on the World Wide Web by accessing URL www.ibm.com/pc/us/netfinity/clustering.html.
Updated 01/01/00
For the latest product & technical information, refer to the Information Sources on pages 1 and 2.
75
IBM NETFINITY 7000 M10
1.Customer supplied Ethernet Crossover Cable may vary in length up to a maximum of 25’ (7.6 m).
IBM Netfinity 8500R Configurator
)
3
)
VD
)
or
)
ns
,L
il)
ax
ss
d)
a
D
r
ax
e
I
M
F
va
a
c
./
M)
./M
RA
D,
l/A
ro
nd
td
,
d
a
D
M
a
P
S
t
t
I
2
t
)
H
t
D
(S
tra
(
y(
To
)
s,
l, S
en bps
e
Ul
=R
tit
s(
rs
Hz
ot
na
r iv
(R
e m t ( M u a l,
an
ay
Sl
o
(M sso B)
)
D
g
i
u
B
,
t
x
p
a
a
na r ne r (D
er
ed oce
sk
(K
il)
il)
yQ
di
(O
e
r
pe
Di
./ M
ow
va
pl
Ma he
va
le
td
ch
Me
cy
E)
(P
rd
l/ A
r S of P
ol
m Et
l/A
r
or S u p
a
S
n
r
D
t
a
a
o
e
e
p
(
a
e
I
t
l
a
t
C
t
t
d
c
s
(
r
b
lH
ry
C
on
To
wa
ys ar
ab
nd
To
Fa wer
m
es
be
OM
na
ov
s(
t-S
. S bo S I C
EC
s(
du
mo
N u r oc u m
rm Po
-R
er
ot
dv On
ay
P
l
N
Ho
Re
rt
em
C
D
L2
Me
Fo
nt
A
B
S
a
S
I
R
C
P
x)
Ma
d ./
t
S
86814RY1
550
1/8
512
256 MBR/
16GB
Rack
(8U)
3/3
P, S, H, F
S-Fans,
S-Power
Y
-
D, U2, L
2/0
0/72.8 GB
40X-17X4
4/2
12/12
86815RY1
550
1/8
1024
512 MBR/
16 GB
Rack
(8U)
3/3
P, S, H, F
S-Fans,
S-Power
Y
-
D, U2, L
2/0
0/72.8 GB
40X-17X4
4/2
12/12
86816RY1
550
1/8
2048
512 MBR/
16 GB
Rack
(8U)
3/3
P, S, H, F
S-Fans,
S-Power
Y
-
D, U2, L
2/0
0/72.8 GB
40X-17X4
4/2
12/12
1. Housed in a 19” Rack mountable drawer and ships standard without a keyboard or mouse. See “Rack and NetBAY” under “Netfinity 8500R Power, Monitor &
Accessories” for supported IBM racks.
2. Intel Pentium III Xeon processor.
3. Netfinity 8500R includes a systems management adapter equivalent to the one shipped with option 01K7209 (Netfinity Advanced System Management PCI Adapter).
4. Variable read rate. Actual playback speed will vary and is often less than the maximum possible.
Netfinity 8500R Processor Upgrades
Part
Number
Processor Upgrades with 512 KB, 1 MB or 2 MB Cache1
Processor Speed/Cache
Upgrade4
4RY2, 3
-
33L5104
Netfinity 8500R 550 MHz/1 MB Upgrade with Pentium III Xeon
Processor3
5RY2, 3
4RY
33L5105
Netfinity 8500R 550 MHz, 2 MB Upgrade with Pentium III Xeon Processor3
6RY2, 3
4...5RY
33L5103
Netfinity 8500R 550 MHz/512 KB Upgrade with Pentium III Xeon Processor3
SMP Support
28L4730
Netfinity 8500R>4-Way Enablement Kit (1X
SRAM)5
All
All
28L4727
Netfinity 8500R>4-Way Enablement Kit (4X SRAM)5
All
All
1. Netfinity 8500R architecture optimizes memory and bus performance using a 100 MHz, five-port crossbar core chipset. Up to eight Pentium III Xeon processors are supported on
two 100 MHz P-6 CPU buses. The recommended order of processor installation is: Sockets A1, A3, A2, A4, B1, B3, B2, B4.
2. Up to seven additional processors may be installed, providing a maximum of eight. All processors must be identical in type, speed, and cache size.
3. For installation of greater than four processors, a Netfinity 8500R>4-way Enablement Kit (1X SRAM, P/N 28L4730) or (4X SRAM, P/N 28L4727) is required. The option of using either
kit with any processor/cache combination provides the opportunity to configure for multiple performance levels. All four standard processor sockets should be populated prior to
installing processors on an Enablement Kit.
4. Requires removal of the standard processor(s). A maximum of eight processors may be installed. Greater than four requires Enablement Kit P/N 28L4730 or 28L4727. For better
performance, all four standard processor sockets should be populated prior to installing processors on an Enablement Kit. All processors must be identical in type, speed and cache
size. Upgrades may require a BIOS update. To obtain the latest Flash BIOS, access www.ibm.com/pc/support and enter machine “Type-Model” in Quick Path. Select “Downloadable
files” and then “BIOS”.
5. Netfinity 8500R>4-Way Enablement Kits consist of a processor daughter board with four Pentium III Xeon processor sockets with terminators. They contain either
two-1X (256 K entries) or two-4x (1 M entries) cache coherency filter modules used to improve bus utilization through effective coherency “snoop” bus traffic management on the
processor buses. The 4X option is for applications that require the highest level of performance in combination with higher performing 2 MB L2 cache processor options.
76
Netfinity 8500R Memory
384
512
640
768
896
1024
1152
1280
1408
1536
1664
1792
2304
2560
2816
3072
3328
4352
4864
5376
5888
6400
8448
9472
10496
11520
12544
13568
14592
16384 (max)
640
768
896
1024
1152
1280
1408
1536
1664
1792
1920
2048
2560
2816
3072
3328
3584
4608
5120
5632
6144
6656
8704
9728
10752
11776
12800
13824
14848
16384 (max)
Quantity of RDIMMs Added
128 MB
(20L0245)
1
2 or
3
4 or
5
6 or
7
8 or
9
10 or
11
12 or
162 or
182or
202 or
222 or
242 or
256 MB
(20L0247)
512 MB
(20L0249)
-
1
2
3
4
5
6
8
9
10
11
12
162
182
202
222
242
262
282
322, 3
1
2 or
3
4 or
5
6 or
8 or
9
10 or
11
12 or
162 or
182 or
202 or
222 or
242 or
-
-
Memory Card A- Std.
Memory Card B- Optional
B1 Socket
A1 Socket Std. RDIMM
A4 Socket
B2 Socket
B3 Socket
B4 Socket
A5 Socket Std. RDIMM
A6 Socket
A7 Socket
A8 Socket
B5 Socket
B6 Socket
B7 Socket
B8 Socket
A2 Socket
A3 Socket
A9 Socket
A10 Socket
A11 Socket
A12 Socket
A13 Socket
A14 Socket
A15 Socket
A16 Socket
(J1-J16)
Std. RDIMM
B9 Socket
B10 Socket
B11 Socket
B12 Socket
Std. RDIMM
B13 Socket
B14 Socket
B15 Socket
B16 Socket
(J1-J16)
Recommended order of RDIMM population for
optimum cooling: 1, 5, 9, 13, 3, 7, 11, 15, 2, 6, 10, 14, 4,
8, 12, 16.
IBM NETFINITY 8500R
Total System Memory1
Standard Models
256 MB
512 MB
(2 x 128)
(4 x 128)
This table does not represent all possible memory configurations.
NOTE: Cache line interleaving may be enabled by installing Netfinity 8500R Memory Expansion Card (P/N
28L4454) with as few as two RDIMMs. Matched pairs must be installed if the memory expansion card is
present.
1. Network Operating Systems may limit the maximum amount of addressable memory. See the operating
system specifications for further information.
2. Netfinity 8500R Memory Expansion Card (P/N 28L4454) is required for installation of greater than 16
RDIMMs.
3. Requires removal of standard memory.
Part Number
Memory Description1
20L0245
Netfinity 128 MB SDRAM ECC RDIMM II
20L0247
Netfinity 256 MB SDRAM ECC RDIMM II
20L0249
Netfinity 512 MB SDRAM ECC RDIMM II
28L4454
Netfinity 8500R Memory Expansion Card2
1. Netfinity 8500R includes a single memory card with the ability to support up to 8 GB of memory. Model 8681-4RY contains two RDIMMs standard,
other models contain four. For memory installation of greater than 8 GB, Netfinity 8500R Memory Expansion Card (P/N 28L4454) is required.
Installation of memory on systems containing a single memory card (standard on all models) has no restrictions on size or placement. When Netfinity
8500R Memory Expansion Card (P/N 28L4454) is installed, the memory RDIMM in each socket of Card A must match the RDIMM in the same socket
on Card B. To enable cache line interleaving, both memory cards must be installed and configured identically.
2. Required for enablement of cache line interleaving or installation of greater than 16 RDIMMs. Configuration of the standard memory card (Card A)
and optional 28L4454 (Card B) must be identical.
Updated 01/01/00
For the latest product & technical information, refer to the Information Sources on pages 1 and 2.
77
Netfinity 8500R Hard Disk Drive (HDD) Storage
Total Internal
Storage1
7200 RPM Hard Disk Drives
(HDDs)
9.1 GB
0 GB
18.2 GB
10,000 RPM HDDs
36.4 GB
9.1 GB
Standard on Base Models
9.1 GB
1 x 36L9744
18.2 GB
-
2 x 36L9744 or 1 x 36L9745
36.4 GB
-
72.8 GB (max)
-
2 x 36L9745 or
-
18.2 GB
36.4 GB
Standard on Base Models
-
1 x 36L9748
-
2 x 36L9748
1 x 36L9746
-
2 x 36L9746
-
-
-
1 x 36L9749
-
2 x 36L9749 or
-
1 x 36L9750
2 x 36L9750
This table does not represent all possible hard drive configurations.
1. Total Internal Storage listed is within + 0.2 GB unless otherwise noted.
Bay
Form
Factor
Height
Front
Access
Usage
RPM
Height
-
5.25”
HH
Yes
IDE CD-ROM
-
3.5”
SL
Yes
Diskette
36L9744
Netfinity 9.1 GB Wide Ultra2 SCSI
Hot-Swap SL HDD
7200
SL
1, 2
2
1...2
HS
HH
Yes
Open
36L9745
Netfinity 18.2 GB Wide Ultra2 SCSI
SL HDD
7200
SL
1, 2
2
Open
36L9746
Netfinity 36.4 GB Wide Ultra2 SCSI
Hot-Swap HDD
7200
HH
1, 2
2
1. A total of three optional 3U NetBAY3Es can be stacked beneath a
Netfinity 8500R which has Netfinity 8Ux28D Rack-to-Tower Kit (P/N
28L4705) installed. See IBM Netfinity NetBAY3x Stackable Enclosure
section for supported devices.
36L9748
Netfinity 9.1 GB 10K-3 Wide Ultra2
SCSI Hot-Swap SL HDD
10000
SL
1, 2
2
36L9749
Netfinity 18.2 GB 10K-3 Wide
Ultra2 SCSI Hot-Swap SL HDD
10000
SL
1, 2
2
36L9750
Netfinity 36.4 GB 10K-3 Wide
Ultra2 SCSI Hot-Swap HDD
10000
HH
1, 2
2
NB3E1
19” Rack
3U
Yes
CD-ROM
Hot-Swap (HS)
Diskette
Bay 1
Bay 2
Netfinity NetBAY3E (NB3E)
(Optional)
(Requires Rack to
Tower Kit)
Part
Number
Description
Bays
Max
Supported Qty.
Internal Hard Disk Drives
(HDD)
External Storage Expansion
Units1
Form Factor
35202RU
Netfinity EXP15 Storage Expansion
Unit
Rack (3U)
35301RU
Netfinity EXP200 Storage
Expansion Unit
Rack (3U)
37L5857
Netfinity EXP200 Rack-to-Tower
Conversion Kit
Tower
1. Not supported by the onboard external SCSI port. Select an optional SCSI controller then refer to Appendix
D: Cables-Storage Units-Controllers to confirm that the controller supports the desired External Storage
Expansion Unit and to select a supported cable. For HDD or other expansion unit options, see the specific
expansion unit section.
Internal SCSI Cabling
Netfinity 8500R systems contains an LVDS backplane supporting two hot-swap drive bays that support installation of up to two 3.5-inch, slim-high or half-high HDDs.
The backplane is connected to the internal Wide Ultra2 SCSI controller through a 16-bit LVD SCSI cable. RAID support for the internal hot-swap drive bays is
provided by adding a supported RAID adapter and moving the standard SCSI cable from the onboard controller to the optional RAID controller. The standard
external Wide Ultra2 SCSI port uses a 0.8-mm Very High Density Connector Interface (VHDCI).
78
.
Netfinity 8500R I/O Options
Part
Number
Description
Adapter
Length
PCI
Support
Slots
Supported1
HotPlug2
PCI Voltage
Key
MHz
Storage Controllers3
01K7364
Netfinity ServeRAID-3L Ultra2 SCSI Adapter4, 5
Full
32-bit
(1...5, 10...12)7
X
5
37L6086
Netfinity ServeRAID-3HB Ultra2 SCSI Adapter6
Full
32/64-bit
(1...5, 10...12)7
X
5
02K3454
PCI Fast/Wide Ultra SCSI Adapter
Half
32-bit
1...5, 10...12
-
5
33
01K7297
Netfinity Fibre Channel PCI Adapter8
Half
32/64-bit
1...5, 10...12
-
5
33
09L2123
Advanced SerialRAID/X Adapter
Full
32-bit
1...12 9
-
Universal
33
Networking
33
10
Ethernet
34L1501
Netfinity 10/100 Ethernet PCI Adapter 2
Half
32-bit
1...12
X
Universal
33
08L3341
Netfinity 10/100 Fault Tolerant Adapter
Half
32-bit
1...5, 10...12
X
5
33
Netfinity Gigabit Ethernet SX Adapter
Half
32/64-bit
1...12
X
Universal
33
34L0301
Token Ring
34L0501
Token-Ring 100/16/4 High-Speed PCI Adapter
Half
32-bit
1...12
-
Universal
33
34L0601
Token-Ring 16/4 PCI Adapter 2
Half
32-bit
1...5, 10...12
X
511
33
33
Communications12
33L4618
PCI V.90 56 Data/Fax Modem13
Half
32-bit
1...5, 10...12
-
5
37L1414
Serial I/O SST8P DB Adapter14
Half
32-bit
(1...5, 10...12)14
-
5
33
37L1415
Serial I/O SST16P RJ Adapter14
Half
32-bit
(1...5, 10...12)14
-
5
33
37L1423
Serial I/O SST16P DB Adapter14
Half
32-bit
(1...5, 10...12)14
-
5
33
Half
32-bit
(1...5, 10...12)14
-
5
33
14
37L1416
Serial I/O SST128P Expandable Adapter
03K9309
Netfinity Advanced Systems Management Interconnect
Cable Kit16
-
-
-
-
-
-
36L9654
Netfinity Advanced System Management Token-Ring
Connection17
-
-
-
-
-
-
-
-
-
-
-
-
Full
32-bit
(1...5, 10...12)20
-
5
33
Systems Management15
02K6545
UltraSlim 56 W AC
Adapter18
9086001
Netfinity ESCON Adapter19
1. The P-6 I/O bus supports four independent 64-bit PCI buses, two of which drive eight 33 MHz, 5.0 V slots (1-5, 10-12), while the other two buses drive four 66 MHz, 3.3 V slots (6-9). The
5 V slots support Universal or 5 V adapters. A 66 MHz adapter plugged into these slots will operate at 33 MHz. The 3.3 V slots support Universal or 3.3 V adapters. A 33 MHz adapter
plugged into these slots limits a 66 MHz PCI adapter installed on the same bus to 33 MHz.
2. All 12 Slots are hot-plug capable using IBM’s Active PCI technology. For Network Operating System support access URL www.ibm.com/pc/us/compat.
3. Netfinity 8500R includes a dual-port, dual-channel, 64-bit Wide Ultra2 SCSI controller which supports either Single Ended (SE) or Low Voltage Differential SCSI (LVDS) modes. One
internal connector and one external port with a 0.8-mm Very High Density Connection Interface (VHDCI) are standard. The internal LVD SCSI cable has sufficient length to attach to an
adapter located in slots 10...12. If a boot device (internal or external) is to be attached to an adapter, the adapter must reside in slots 10...12 due to BIOS scanning sequences.
4. All ServeRAID-3x adapters can be upgraded with the same enhanced software utilities and firmware included with ServeRAID-3HB. The download is available for no charge from
www.ibm.com/support. Select “Server” in Brand pull-down, “ServeRAID” in Family pull-down and then “Downloadable files”. The upgrade should be considered for installations with firmware
less than Version 3.5.
5.Netfinity ServeRAID-3L Ultra2 SCSI Adapter (P/N 01K7364) provides either one internal or one external (0.8-mm VHDCI) LVDS SCSI channel.
6. Netfinity ServeRAID-3HB Ultra2 SCSI Adapter (P/N 37L6086) provides one internal and two external (0.8 mm VHDCI) LVDS SCSI c hannels. The internal channel can be configured for
external usage (0.8 mm VHDCI) providing a total of three external LVDS SCSI channels. Includes 32 MB of mirrored battery-backu p cache, which helps protect against data loss in writeback cache mode in the event of a power outage or adapter maintenance.
7. A total quantity of eight, in any combination of 01K7363, 37L6086, and 01K7207 is supported.
8. See Netfinity Fibre Channel Solutions section for additional configuration information.
9. A maximum quantity of four is supported.
10. Netfinity 8500R does not include an onboard network controller.
11. Early versions of Token-Ring 16/4 PCI Adapter 2 (P/N 34L0601) were keyed as Universal; current versions are keyed for 5 V. All versions are supported in 5 V PCI slots only.
12. Netfinity 8500R includes two USB ports, two high-speed serial/asynchronous ports, (NS 16550A compatible), and one high-speed (up to 2 MBps data transfer speed)
bi-directional parallel port supporting devices using ECP/EPP/SSP protocols adhering to the IEEE 1284 standard.
13. Due to homologation variances, modem availability may differ by country.
14. See Appendix E for details on Serial I/O options and configuration limitations. A maximum of four Serial I/O adapters (any combination of P/N 37L1414, 37L1415, 37L1416, 37L1423) may be
installed.
15. Netfinity 8500R ships standard with a Netfinity Advanced System Management PCI Adapter.
16. Required for all Netfinity Servers containing a standard Advanced System Management Processor that are to be interconnected for system management support through a LAN or
modem connection (Netfinity 5500 models 8660-1...4xU are not supported). Up to 12 service processors may be interconnected (including standard and optional processors) with an
aggregate connection length of no more than 91.4 meters (300 ft). A customer-supplied Ethernet cable is required for each interconnection.
17. Contains an IBM Turbo 16/4 Token-Ring PCI Card, which installs in the PCMCIA card slot of Netfinity Advanced System Management PCI Adapter and a PC Card to 9-pin D-Shell cable
which is routed to a rear chassis cut-out. The Netfinity Advanced System Management PCI Adapter’s integrated Ethernet port and Netfinity Advanced System Management Token-Ring
Connection cannot be connected or used together. To download the latest firmware, access URL www.ibm.com/pc/us/netfinity. Select “Server Support”, “Family”, “Model”, “Downloadable
Files” and finally “Advanced System Management”.
18. Although the 8500R integrated Netfinity System Management PCI Adapter is powered continuously through the redundant power supply subsystem, an even higher level of availability is
offerred with the addition of UltraSlim 56 W AC Adapter by allowing an independent power source or connection to a separate optional UPS.
19. Provides an ESCON MIC and DB9 Serial Port. Cables are not included but are available through S/390 channels. Contact your IBM representative for additional information.
20. A maximum of two 9086001 adapters (installed in non-adjacent slots) are supported in a single Netfinity server.
Updated 01/01/00
For the latest product & technical information, refer to the Information Sources on pages 1 and 2.
79
IBM NETFINITY 8500R
Host Attach
Slot 12- Bus A- 33 MHz- 5 V or Universal
Slot 11- Bus A- 33 MHz- 5 V or Universal
Slot 10- Bus A- 33 MHz- 5 V or Universal
Slot 9- Bus B- 66 MHz- 3.3 V or Universal
Slot 8- Bus B- 66 MHz- 3.3 V or Universal
Slot 7- Bus C- 66 MHz- 3.3 V or Universal
Slot 6- Bus C- 66 MHz- 3.3 V or Universal
Slot 5- Bus D- 33 MHz- 5 V or Universal
Slot 4- Bus D- 33 MHz- 5 V or Universal
Slot 3- Bus D- 33 MHz- 5 V or Universal
Slot 2- Bus D- 33 MHz- 5 V or Universal
Slot 1- Bus D- 33 MHz- 5 V or Universal
Full Length, 64-bit, Hot-Plug PCI Slots
Netfinity 8500R Power, Monitor & Accessories
Part
Number
Description
Part
Number
Power1
Conversion Kits
Uninterruptible Power Supply (UPS)2
94G6676
Description
28L4705
Rack and NetBAY2
APC Smart-UPS 3000RMB (16 min. runtime at 1015 Watts)3
4
Monitors
Netfinity 8Ux28D Rack-to-Tower Kit1
930842P
Netfinity Enterprise Rack
65464AN
G54 Color Monitor 15” (13.7” Viewable Image Size), stealth black5
930842X
Netfinity Enterprise Expansion Cabinet
65474AN
G74 Color Monitor 17” (15.9 Viewable Image Size), stealth black5
9306900
Netfinity Rack3
65494AN
G96 Color Monitor 19” (17.9” Viewable Image Size), stealth black6
36L9703
Netfinity Rack Extension Kit
9513AG1
T55A Flat Panel Color Monitor (15.0” Viewable Image Size),
stealth black7
9306200
Netfinity NetBAY224
36L9702
NetBAY22 Rack Extension Kit
36L9701
Netfinity NetBAY3E5
28L3644
Space Saver II Keyboard7, 8
1.Netfinity 8500R systems contain three 750 W (at 220 V), hot-swap power supplies which
handle robust configurations while providing full redundancy. When operating at 110 V,
redundancy is limited to configurations not exceeding six processors, 24 memory RDIMMs, or
eight PCI adapters. Each system ships with 9 power cords: 3 x 220 V, 3 x 110 V, 3 x intra-rack
220 V. Even though multiple UPSs may provide redundant power sources, systems
management software does not currently take advantage of its power outage alerts.
2. Stated runtimes and power are for typical configurations (approximately 70% of maximum
capacity). For additional information see Appendix C: UPS Runtime Estimate.
3. Height is 3U. See “Rack and NetBAY” for supported IBM racks.
4. Netfinity 8500R uses an SVGA controller (S3 Trio 3D chipset) with 4 MB of video memory.
5. Installation within a rack requires optional Monitor Compartment (P/N 94G7444).
6. Not supported for installation in a 19” rack
7. Installation within a rack requires optional Netfinity Flat Panel Monitor Rack Mount Kit (P/N
37L6857) and Netfinity Rack Keyboard Tray (P/N 28L4707). A space saver keyboard may
coexist within the same 28L4707 keyboard tray.
Keyboard and Mouse6
1
80
01K1260
TrackPoint IV 104-Key Black Keyboard8, 9
28L3621
Preferred Keyboard (stealth black)9
28L3673
Sleek 2-Button Stealth Black Mouse
1. Includes casters, which can also be used with NetBAY3E.
2. Netfinity 8500R is housed in a 19” rack mountable drawer and requires one of the racks
listed here. See “IBM Netfinity Rack Cabinet and Options” section for IBM rack supported
devices.
3. Netfinity Rack Extension Kit (P/N 36L9702) is required for proper rear door closure
clearance.
4. NetBAY22 Rack Extension Kit (P/N 36L9703) is required for proper rear door closure
clearance.
5. A maximum of three NetBAY3E enclosures may be stacked beneath a supported
Netfinity tower server (conversion kit 28L4705 required). See IBM Netfinity NetBAY3X
Stackable Enclosure section for supported devices.
6.Netfinity 8500R ships without a keyboard or mouse.
7. Installation within a rack requires optional keyboard tray P/N 28L4707 (stows in “ready-touse” position).
8. Advanced TrackPoint IV features are not available on IBM Netfinity sy.stems.
9. Installation within a rack requires optional keyboard tray P/N 28L4707. This keyboard
cannot share a keyboard tray with a flat panel display.
.
Netfinity 8500R Tape Options
Part
Number
Description
Bays
SCSI
Form Factor
Supported Interface
(bit)
Termination 68/50-pin Ext. Tape
Included
Converter
Encl.1
Incl.
35100204
3551001
3503B0X,
3551001
3503B0X4,
3551001
3503B0X4,
3551001
01K1325
20/40 GB 8-mm Internal SCSI Tape Drive
N/A2
16
5.25”HH
N
N
01K1320
20/40 GB DLT Internal SCSI Tape Drive
N/A2
8
5.25”FH
Y3
Y
04K0149
35/70 GB DLT Internal SCSI Tape Drive
N/A2
16
5.25”FH
N
N
40/80 GB DLT Internal SCSI Tape Drive
N/A2
16 LVD
5.25” FH‘
N
N
-
16
External
Y
N
3510020,
3503B0X
-
8/16
16
16
16
Desktop
Rack
Desktop
N
Y
N
N
N
N
N
N
3551001
-
-
16
16
16 LVD
16 LVD
Desktop
Desktop or Rack
Desktop
Desktop or Rack
Y
Y
Y
Y
-
-
-
Differential
Desktop or Rack
Y
-
-
00N7990
Associated Options
32G3918
SCSI-2 16-bit Active Terminator
3510020
3551001
10L7113
3503BOX
External Half High SCSI Storage Enclosure5
NetMEDIA Storage Expansion Unit EL6
NetMEDIA Systems Management Adapter7
DLT External SCSI Enclosure8
3502108
3502x14
3503108
3503x14
DLT Tape Autoloader
DLT Tape Library
DLT8000 Tape Autoloader
DLT8000 Tape Library
Magstar MP 3570 Tape Subsystem (models
B2x and C2x)
External Tape Enclosures
3570xxx
1. To determine cable requirements, note the tape drive’s SCSI interface, the appropriate SCSI controller from the system configurator section and the desired enclosure, then refer to
Appendix D: Cables - Storage Units - Controllers.
2. Netfinity 8500R supports tape drives installed in external enclosures only. See External Tape Enclosure column.
3. Tape drive is capable of self termination.
Provides a black desktop 5.25” half-high (HH) tape enclosure. Connector is configurable as 50-pin Centronix or 68-pin high density. Requires either tape drive self-termination or SCSI-2 16bit Active Terminator (P/N 32G3918).
4. Requires SCSI-2 16-bit Active Terminator (P/N 32G3918).
5. Provides a black desktop 5.25” half-high (HH) tape enclosure. Connector is configurable as 50-pin Centronix or 68-pin high density. Requires either tape drive self termination or SCSI-2 16bit Active Terminator (P/N 32G3918).
6. Provides a black 3U, 19” rack or NetBAY3 mountable tape enclosure. Provides two full high (FH) or four half high (HH) extended length 5.25” bays. External connector is 0.8mm VHDCI.
Includes two power supplies and two power cords.
7. Installs in 3551001. Provides repeater function and LVDS interface allowing longer cable lengths and auto-termination when the 3551001 is powered off.
8. Provides a black desktop DLT tape enclosure with a 68-pin high density external connector. Requires termination by the tape drive or by installation of a SCSI-2 16-bit Active Terminator
(P/N 32G3918).
9. Tape library attributes and prerequisites are located in Appendix B: Tape Library Attributes.
NOTE: SCSI support for tape drives is provided by system unit onboard (standard) controller (no-RAID function) or PCI Fast Wide Ultra SCSI Adapter P/N 02K3454. Additional tape attributes
can be found in Appendix A: Tape Drive Attributes.
Updated 01/01/00
For the latest product & technical information, refer to the Information Sources on pages 1 and 2.
81
IBM NETFINITY 8500R
External Tape Libraries9
Sample Configurations
The following sample configurations are for illustration only and may not be suitable for any specific customer installation. Contact your IBM Business Partner or IBM
Marketing Representative for assistance with your specific configuration requirements.
High Availability-Rack
Part Number
Quantity
Usage
8681-4RY
Netfinity 8500R (PIII Xeon 550/512 KB 256 MB/Rack)
Description
1
Power Redundancy standard
33L5103
Netfinity 8500R 550 MHz/512 KB Upgrade with Pentium III Xeon Processor
5
Total of 6 SMP processors
28L4730
Netfinity 8500R>4-Way Enablement Kit (1X SRAM)
1
Required for greater than 4 processors
20L0247
Netfinity 256 MB SDRAM ECC RDIMM II
8
Total of over 2 GB of memory
28L4454
Netfinity 8500R Memory Expansion Card
1
Enables cache line interleaving
36L9744
Netfinity 9.1 GB Wide Ultra2 SCSI Hot-Swap SL HDD
2
NOS mirroring
37L6086
Netfinity ServeRAID-3HB Ultra2 SCSI Adapter
1
RAID Controller - NOS plus EXP200
-
34L1501
Netfinity 10/100 Ethernet PCI Adapter 2
1
65464AN
G54 Color Monitor 15” (13.7” Viewable Image Size), stealth black
1
-
28L3644
Space Saver II Keyboard
1
-
94G6676
APC Smart-UPS 3000RMB
1
External Tape Drive Enclosure
External Storage
3551001
NetMEDIA Storage Expansion Unit EL
1
00N7990
40/80 GB DLT Internal SCSI Tape Drive
2
Installs in 3551001
35301RU
Netfinity EXP200 Storage Expansion Unit
1
Provides additional 10 bays
37L0075
Netfinity EXP200 350 W Redundant Power Supply
1
-
03K9311
Netfinity 4.2 M Ultra2 SCSI Cable
2
Tape to Onboard SCSI, 3-HB to EXP200
36L9748
Netfinity 9.1 GB 10K-3 Wide Ultra2 SCSI Hot-Swap SL HDD
6
RAID 5 with Hot-Spare in EXP200
Rack Options
9306200
Netfinity NetBAY22
1
Monitor and keyboard mount on top
36L9702
NetBAY22 Rack Extension Kit
1
Required for rear door closure
94G6667
Power Cable - Type A14 (4)
5
-
94G6670
Blank Filler Panel Kit
1
-
This high availability server is configured to act as the foundation for business critical applications, applications your business cannot afford to be without. The
configuration includes enough disk drives to mirror the operating system and provide a RAID 5 data environment, power supply redundancy by the server and
EXP200 and a UPS for power even during a blackout. A rack mounted tape drive is included to back up that all important asset...data. This server represents the
leading edge in high availability.
Notes/Exchange-Stack
Part Number
Quantity
Usage
8681-5RY
Netfinity 8500R (PIII Xeon 550/1 MB 512 MB/Rack)
Description
1
Power redundancy standard
33L5104
Netfinity 8500R 550 MHz/1 MB Upgrade with Pentium III Xeon Processor
5
Total of 6 SMP processors
28L4727
Netfinity 8500R>4-Way Enablement Kit (4X SRAM)
1
Required for greater than 4 processors
20L0249
Netfinity 512 MB SDRAM ECC RDIMM II
3
Total of 2 GB of memory
28L4454
Netfinity 8500R Memory Expansion Card
1
Enables cache line interleaving
NOS Mirroring
36L9744
Netfinity 9.1 GB Wide Ultra2 SCSI Hot-Swap SL HDD
2
34L1501
Netfinity 10/100 Ethernet PCI Adapter 2
1
-
37L6086
Netfinity ServeRAID-3HB Ultra2 SCSI Adapter
1
NOS plus EXP200
65464AN
G54 Color Monitor 15” (13.7” Viewable Image Size), stealth black
1
-
28L3644
Space Saver II Keyboard
1
-
94G6676
APC Smart-UPS 3000RMB
1
External Tape Enclosure - Install in NetBAY3E
External Storage
3551001
NetMEDIA Storage Expansion Unit EL
1
00N7990
40/80 GB DLT Internal SCSI Tape Drive
2
Installs in 3551001
03K9310
Netfinity 2M Ultra2 SCSI Cable
1
Tape to Onboard SCSI
35301RU
Netfinity EXP200 Storage Expansion Unit
1
Provides additional 10 Bays, 1 x 2M cable
37L0075
Netfinity EXP200 350 W Redundant Power Supply
1
-
36L9749
Netfinity 18.2 GB 10K-3 Wide Ultra2 SCSI Hot-Swap SL HDD
10
RAID 5 with Hot-Spare in EXP200
28L4705
Netfinity 8Ux28D Rack-to-Tower Kit
1
-
36L9701
Netfinity NetBAY3E
3
3 x 3U enclosure for UPS, EXP200, Tape
Stack Options
82
Two Node High Availability Cluster
Public
LAN
Server Node A
ServeRAID-3HB
(37L6086)
CH3
CH2
CH1
10/100 Ethernet (34L1501)
10/100 Ethernet (34L1501)
(2 m cable std. (03K9311)
(25’ Ethernet
Crossover Cable1)
Netfinity EXP200
on EXP200)
Server Node B
CH3
CH2
CH1
10/100 Ethernet (34L1501)
ServeRAID-3HB
(37L6086)
10/100 Ethernet (34L1501)
Public
LAN
1.Customer supplied Ethernet Crossover Cable may vary in length up to a maximum of 25’ (7.6 m).
Part Number
Two Node High Availability Cluster
Description
Server Nodes A & B
8681-6RY
33L5105
28L4727
20L0247
28L4454
34L1501
37L6086
36L9744
94G6676
Netfinity 8500R (PIII Xeon 550/2 MB 512 MB/Rack) (8U)
Netfinity 8500R 550 MHz/2 MB Upgrade with Pentium III Xeon Processor
Netfinity 8500R>4-Way Enablement Kit (4X SRAM)
Netfinity 256 MB SDRAM ECC RDIMM II
Netfinity 8500R Memory Expansion Card
Netfinity 10/100 Ethernet PCI Adapter 21
Netfinity ServeRAID-3HB Ultra2 SCSI Adapter2
Netfinity 9.1 GB Wide Ultra2 SCSI Hot-Swap SL HDD
APC Smart-UPS 3000RMB (3U)
3551001
03K9311
00N7990
35301RU
37L0075
03K9311
36L9748
NetMEDIA Storage Expansion Unit EL (3U)
Netfinity 4.2 M Ultra2 SCSI Cable3
40/80 GB DLT Internal SCSI Tape Drive
Netfinity EXP200 Storage Expansion Unit (3U)2
Netfinity EXP200 350 W Redundant Power Supply2
Netfinity 4.2 M Ultra2 SCSI Cable2, 3
Netfinity 9.1 GB 10K-3 Wide Ultra2 SCSI Hot-Swap SL HDD
9513AG1
28L3644
T55A Flat Panel Color Monitor (15.0” Viewable Image Size), stealth black
Space Saver II Keyboard
930842P
37L6857
28L4707
28L0542
94G6667
94G7447
94G6670
Netfinity Enterprise Rack
Netfinity Flat Panel Monitor Rack-Mount Kit (3U)
Netfinity Rack Keyboard Tray
Netfinity Console Server Selector Switch (4-port)
Power Cable-Type A143
12 ft. Console Cable Set
Blank Filler Panel Kit
Quantity
Usage
2
10
2
16
2
4
2
4
2
Power redundancy standard
Total of 6 SMP processors per node
Required for greater than 4 processors
Total of over 2 GB of memory per node
Enables cache line interleaving
1 for crossover, 1 for public LAN/node
RAID controller - NOS plus EXP200
NOS mirroring
-
1
1
1
1
1
2
10
External Tape Drive Enclosure
3551001 to onboard SCSI
Installs in 3551001
Provides additional 10 bays
3-HB to EXP200
RAID 5 shared storage in EXP200
1
1
Mounts in keyboard tray
-
1
1
1
1
4
2
1
Mounts in keyboard tray
-
IBM NETFINITY 8500R
External Storage
Shared (or single occurrence) Resources
Rack Options
1. Requires customer supplied Ethernet Crossover Cable which may vary in length up to a maximum of 25’ (7.6 m).
2. By replicating these items, up to a total quantity of four ServeRAID-3HB Adapters (plus options) and eleven EXP200s can provide over 2 Terabytes of storage. Additional power and rack
space will be required.
3. Cable length requirements are dependent on component placement within the rack or rack suite. To determine specific configuration requirements use the Netfinity Rack Configurator.
Clustering is a group of interconnected computers used as a single, unified computing resource. Clustering Netfinity servers, like the IBM Netfinity 8500R, provides a high availability solution to
keep you in touch with the key applications you need to run your business.
This sample configuration consists of paired IBM Netfinity 8500R cluster nodes equipped with eight-way SMP capability and redundant power supplies. Microsoft Cluster Service (MSCS) has
been validated on IBM Netfinity 8500R servers, using the Netfinity ServeRAID-3HB with the EXP200 Storage Expansion Unit. MSCS allows two configured servers, referred to as nodes, to be
connected together to form a cluster. Providing system redundancy means that a complete server can fail and client access to server resources is largely unaffected. MSCS extends this theme
by also allowing for software failures at an application level as well as an operating system level. If the operating system fails, all applications and services can be restarted on another server,
and if just one application fails, it can be managed by MSCS individually. An additional independent network connection is used to perform monitoring within the cluster. One or more disk
subsystems are attached to both nodes. In the above example, a Netfinity EXP200 was selected and the Netfinity ServeRAID-3HB Ultra2 SCSI Adapters provide the I/O control. Netfinity
ServeRAID-3HB handles the “SCSI heartbeat” connection without the need for a dedicated SCSI connection and logically attaches t he quorum disk, which allows arbitration when a failure
occurs. Additional information on IBM Netfinity and IBM PC Server Clustering Solutions may be found on the World Wide Web by accessing URL www.ibm.com/pc/us/netfinity/clustering.html.
Updated 01/01/00
For the latest product & technical information, refer to the Information Sources on pages 1 and 2.
83
IBM External Storage Expansion Unit Overview
ci
pa
1
)
yy
dd
r
Pa
tN
um
be
r
W
m
(m
e
pe
at
Ty
D
l
m
s
a
e
ay
st
aw
lB
sy
dr
a
b
h
t
it
Su
To
B)
Ca
ble
H)
il a
ge
x
va
ra
D
a
o
t
,
x
l
S
a
W
al
ot
.) (
rn
:t
( in
te
ys
n
a
s
I
or
n
ct
io
pB
um
Fa
ns
m
wa
i
e
S
m
x
r
m
tMa
Fo
Di
Ho
x
Ma
.
fg
.C
.(
Wt
lb
)
rS
we
Po
up
35202RU
Netfinity EXP15
-
Ultra SCSI2
LVDS
10
10, 10
364
17.6 x 22.5 x 5.1
Rack Drawer (3U)
92
Redundant
350 Watts
35301RU
Netfinity EXP200
-
Ultra2 SCSI
LVDS
10
10, 10
364
17.6 x 22.5 x 5.1
Rack Drawer
(3U)3
79
350 Watts4
To attach a Storage Enclosure to an IBM Netfinity or PC Server, the following is required:
Attachment to an appropriate PC Server SCSI or SSA controller.
External Cable(s) - See Appendix D: Cables - Storage Units - Controllers.
1. Not available from IBM after this date. Business Partner inventory may be available.
2. See IBM Netfinity EXP15 Configurator Limitations section for additional information.
3. A rack-to-tower conversion kit option is available.
4. A redundant power supply is available.
84
(G
ty
ply
IBM STORAGE
EXPANSION UNIT
Updated 01/01/00
For the latest product & technical information, refer to the Information Sources on pages 1 and 2.
85
IBM Netfinity EXP15 (3520-2RU) Configurator
Netfinity EXP15 Hard Disk Drive (HDD) Storage
Total Internal
Storage1
7,200 RPM Hard Disk Drives (HDDs)
9.1 GB
0 GB
18.2 GB
10,000 RPM Hard Disk Drives
(HDDs)
36.4 GB
9.1 GB
Standard on all Base Models
18.2 GB
2 x 01K7959 or
1 x 01K8501
36.2 GB
4 x 01K7959 or
2 x 01K8501 or
54.6 GB
6 x 01K7959 or
3 x 01K8501
72.8 GB
8 x 01K7959 or
4 x 01K8501 or
91.0 GB
10 x 01K7959 or
5 x 01K8501
109.2 GB
-
6 x 01K8501 or
18.2 GB
36.4 GB
Standard on all Base Models
-
1 x 02K0442
2 x 02K0442
-
2 x 36L9809 or
1 x 36L9810
4 x 36L9809 or
2 x 36L9810 or
6 x 36L9809 or
3 x 36L9810
8 x 36L9809 or
4 x 36L9810 or
10 x 36L9809 or
5 x 36L9810
1 x 36L9811
2 x 36L9811
-
3 x 02K0442
-
6 x 36L9810 or
3 x 36L9811
145.6 GB
-
8 x 01K8501 or
4 x 02K0442
-
8 x 36L9810 or
4 x 36L9811
182..0 GB
-
10 x 01K8501 or
5 x 02K0442
-
10 x 36L9810 or
5 x 36L9811
218.4 GB
-
-
6 x 02K0442
-
-
6 x 36L9811
254.8 GB
-
-
7 x 02K0442
-
-
7 x 36L9811
291.2 GB
-
-
8 x 02K0442
-
-
8 x 36L9811
327.6 GB
-
-
9 x 02K0442
-
-
9 x 36L9811
364 (max)
-
-
10 x 02K0442
-
-
10 x 36L9811
This table does not represent all valid hard drive configurations.
1. Total Internal Storage listed is within +- 0.2 GB unless otherwise noted.
Bay
Form Height Front Usage BUS
Factor
Access
Odd #s
Even #s
HS
HH
HS
yes
HH
yes
open
open
1
2
2 x 0.8mm VHDCI
Connectors
EXP151
Netfinity
3520-2RU
On - 2 x 5 bay bus
Part
Number
Description
RPM
Height
Bays
Max. Qty
Supported Supported
01K7959
Netfinity EXP10 9.1 GB Wide
Ultra SCSI SCA-2 HDD
7200
HH
All
10
01K8501
Netfinity EXP10 18.2 GB Wide
Ultra SCSI SCA-2 HDD
7200
HH
All
10
02K0442
Netfinity EXP 36.4 GB Wide
Ultra SCSI SCA-2 HDD
7200
HH
All
10
36L9809
Netfinity EXP 9.1 GB 10K-3 Wide
Ultra SCSI Hot-Swap HDD
10,000
SL
All
10
36L9810
Netfinity EXP 18.2 GB 10K-3
Wide Ultra SCSI Hot-Swap HDD
10,000
SL
All
10
36L9811
Netfinity EXP 36.4 GB 10K-3
Wide Ultra SCSI Hot-Swap HDD
10,000
HH
All
10
Switch
Off - 1 x 10 bay bus
Bay 1
Bay 2
Bay 3
Bay 4
Bay 5
Bay 6
Bay 7
Bay 8
Bay 9
Bay 10
External: LVD SCSI
Internal: Single Ended SCSI
Auto Termination
1. Housed in a 19” rack mountable drawer and ships standard with
redundant power supplies and two power cables requiring separate
power sources.
Requires IBM Netfinity Enterprise Rack (930842P) or Expansion
Cabinet (930842X), Rack (9306900), NetBAY22 (9306200), NetBAY3
(10L6912) or NetBAY3E (36L9701.)
External Storage Expansion Units require storage controllers and
external cables. Select a supported controller from the system
configurator and cables from Appendix D: Cables-Storage UnitsControllers.
Limitations
The Netfinity EXP15 is not supported when the SCSI channel of the SCSI adapter to which it is attached is split between internal devices and external devices. Each
Netfinity EXP15 must be attached to a dedicated SCSI channel of a supported SCSI adapter. Ultra SCSI mode is not supported when external cables are greater
than 2.0 meters in length unless attached to a supported Ultra-2 SCSI adapter (other restrictions may apply; see Appendix D). Netfinity EXP15 is supported as a rack
drawer and is not supported for stacking directly on top of one another. Netfinity EXP15 can be installed in Netfinity NetBAY3 storage units stacked up to three units
high with a supported server on top.
86
Cables and Controllers:
See Appendix D: Cables - Storage Units - Controllers
Sample Configurations
The following sample configurations are for illustration only and may not be suitable for any specific customer installation. Contact your IBM Business Partner or IBM
Marketing Representative for assistance with your specific configuration requirements.
Netfinity EXP15 Two Independent SCSI Buses
Netfinity EXP15 One Independent SCSI Bus
To configure as a single 10 drive SCSI channel, attach one external
cable from the SCSI adapter to either the 1 IN or 2 IN connectors in the
EXP15. Set switch 1 to “Off” position.
To configure as two independent 5 drive SCSI channels, attach one
external cable from the SCSI adapter to the SCSI bus 1 IN connector in
the EXP15. Attach a second External SCSI cable from another SCSI
adapter, in the same or separate server, to the 2 IN connector in the
unit. Set switch 1 to “On” position.
Server SCSI
Adapter
Order:
1 x 3520-2RU
2 x External Cables
See Cables - Storage Units Controllers section
Up to 10 Disk Drives
19” Rack Space
SERVER
Order:
1 x 3520-2RU
1 x External Cable
See Cables - Storage Units Controllers section
Up to 10 Disk Drives
19” Rack Space
SERVER
Server SCSI
Adapter
Server SCSI
Adapter
External cables
2 IN
Operational mode (SCSI
F/W, Ultra SCSI, Ultra-2
SCSI) may be limited by
controller, cable, cable
length, or hard disk drive
type. See Appendix D for
additional information.
0.8 mm VHDCI
Netfinity Fibre Channel RAID
Controller Unit - 35261RU
0.8 mm VHDCI
Server SCSI
Adapter
To configure the Netfinity EXP15 for either cluster or non-cluster
applications using a 35261RU, follow the same attachments outline above.
Utilizing Fibre Solutions provides support for large amounts of highperformance, RAID protected data storage at distances of up to 10 KM (6
miles) from the server.
0.8 mm VHDCI
Order:
1 x 3520-2RU
2 x External Cables
See Cables - Storage Units Controllers section
Up to 10 Disk Drives
19” Rack Space
Node A
Netfinity Fibre Channel Solutions
Configuration
0.8 mm VHDCI
Netfinity EXP15 One Independent SCSI Bus
High Availability Configuration
To configure a single 10 drive SCSI channel for clustering, attach one
external cable from the SCSI adapter in Node A to the 1 IN connector in
the EXP15. Connect a second external cable to a SCSI adapter in Node B
and to the 2 IN connector in the EXP15.
Server SCSI
Adapter
Operational mode (SCSI
F/W, Ultra SCSI, Ultra-2
SCSI) may be limited by
controller, cable, cable
length, or hard disk drive
type. See Appendix D for
additional information.
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
Node B
Standard Repeater Card
0.8 mm VHDCI
Standard Repeater Card
On
0.8 mm VHDCI
Off
Switch 1
1 IN
1 IN
2 IN
External cable
Switch 1
IBM NETFINITY EXP15
(or)
One Independant Bus
• 1 connection only
• Switch 1 off
Two Independant Bus
• 2 connections
• Switch 1 on
1 IN
2 IN
External cables
Switch1
Off
Standard Repeater Card
1 2 3 4 5 6 7 8 9 10
Updated 01/01/00
Operational mode (SCSI
F/W, Ultra SCSI, Ultra-2
SCSI) may be limited by
controller, cable, cable
length, or hard disk drive
type. See Appendix D for
additional information.
Switch 1
Standard Repeater Card
See Appendix D for cable
selection
1 2 3 4 5 6 7 8 9 10
For the latest product & technical information, refer to the Information Sources on pages 1 and 2.
87
IBM Netfinity EXP200 (35301RU) Configurator
Netfinity EXP200 Hard Disk Drive (HDD) Storage
Total Internal Storage1
7,200 RPM Hard Disk Drives (HDDs)
9.1 GB
0 GB
18.2 GB
10,000 RPM Hard Disk Drives (HDDs)
36.4 GB
9.1 GB
Standard on all Base Models
18.2 GB
2 x 36L9744 or
1 x 36L9745
36.2 GB
4 x 36L9744 or
2 x 36L9745 or
54.6 GB
6 x 36L9744 or
3 x 36L9745
72.8 GB
8 x 36L9744 or
4 x 36L9745 or
91.0 GB
10 x 36L9744 or
109.2 GB
1 x 36L9746
2 x 36L9746
-
5 x 36L9745
-
6 x 36L9745 or
18.2 GB
36.4 GB
Standard on all Base Models
2 x 36L9748 or
1 x 36L9749
4 x 36L9748 or
2 x 36L9749 or
6 x 36L9748 or
3 x 36L9749
8 x 36L9748 or
4 x 36L9749 or
10 x 36L9748 or
5 x 36L9749
1 x 36L9750
2 x 36L9750
-
3 x 36L9746
-
6 x 36L9749 or
3 x 36L9750
145.6 GB
-
8 x 36L9745 or
4 x 36L9746
-
8 x 36L9749 or
4 x 36L9750
182..0 GB
-
10 x 36L9745 or
5 x 36L9746
-
10 x 36L9749 or
5 x 36L9750
218.4 GB
-
-
6 x 36L9746
-
-
6 x 36L9750
254.8 GB
-
-
7 x 36L9746
-
-
7 x 36L9750
291.2 GB
-
-
8 x 36L9746
-
-
8 x 36L9750
327.6 GB
-
-
9 x 36L9746
-
-
9 x 36L9750
364 (max)
-
-
10 x 36L9746
-
-
10 x 36L9750
This table does not represent all valid hard drive configurations.
1. Total Internal Storage listed is within +- 0.2 GB unless otherwise noted.
Bay
Form Height Front Usage BUS
Factor
Access
Odd #s
Even #s
HS
HH
HS
yes
HH
yes
open
open
2 x 0.8mm VHDCI
Connectors
EXP2001
Netfinity
3530-1RU
On - 2 x 5 bay bus
1
2
Part
Number
Off - 1 x 10 bay bus
RPM
Height
Bays
Max. Qty
Supported Supported
36L9744
Netfinity 9.1 GB Wide Ultra2
SCSI Hot-Swap SL HDD
7200
SL
1...10
10
36L9745
Netfinity 18.2 GB Wide Ultra2
SCSI Hot-Swap SL HDD
7200
SL
1...10
10
36L9746
Netfinity 36.4 GB Wide Ultra2
SCSI Hot-Swap HDD
7200
HH
1...10
10
36L9748
Netfinity 9.1 GB 10K-3 Wide
Ultra2 SCSI Hot-Swap SL HDD
10,000
SL
1...10
10
36L9749
Netfinity18.2 GB 10K-3 Wide
Ultra2 SCSI Hot-Swap SL HDD
10,000
SL
1...10
10
36L9750
Netfinity 36.4 GB 10K-3 Wide
Ultra2 SCSI Hot-Swap HDD
10,000
HH
1...10
10
37L5857
Netfinity EXP200 Rack-to-Tower
Conversion Kit
37L0075
Netfinity EXP200 350 W
Redundant Power Supply1
Switch
1. The EXP200 includes a single hot-swap 350 W power supply and power cord. Optional hot-swap Netfinity
EXP200 350 W Redundant Power Supply (P/N 37L0075) includes an additional power cord.
Bay 1
Bay 2
Bay 3
Bay 4
Bay 5
Bay 6
Bay 7
Bay 8
Bay 9
Bay 10
External: LVD or SE SCSI
Internal: LVD SCSI
Auto Termination
Description
1. Housed in a 19” rack mountable drawer and ships standard with a single power supply, power cord and 2 meter Ultra2
SCSI cable. Requires IBM Netfinity Enterprise Rack (930842P) or Expansion Cabinet (930842X), Rack (9306900),
NetBAY22 (9306200), NetBAY3 (10L6912) or NetBAY3E (36L9701). External Storage Expansion Units require storage
controllers and external cables. Select a supported controller from the system configurator and cables from Appendix D:
Cables - Storage Units - Controllers.
Limitations
Netfinity EXP200 hot-swapping of HDDs is restricted to a HDD that is inactive or where a lighted fault LED is indicated. The EXP200 is not
supported when the SCSI channel of the SCSI adapter to which it is attached is split between internal devices and external devices. Each
EXP200 must be attached to a dedicated SCSI channel of a supported SCSI adapter. The standard EXP200 configuration is supported as a
rack drawer and is not currently supported for stacking directly on one another. It can be installed in a Netfinity NetBAY3 or NetBAY3E storage
unit and stacked up to three units high, with a supported server on top. In addition, it can be converted to a tower with the addition of a Netfinity
EXP200 Rack-to-Tower Conversion Kit (37L5857). See Appendix D: Cables- Storage Units- Controllers for supported controllers and cables. A
single two meter cable is included with the EXP200.
88
Cable Length
(Meters)1
Ultra2 Controller
Maximum MB/s
Ultra Controller
1 and 2
80
40
3
80
20
4.3
80
20
12 and 20
80
N/A
1. The EXP200 ships with a single Ultra2 SCSI cable similar to Netfinity 2 M Ultra2 SCSI Cable (P/N 03K9310).
Cables and Controllers:
See Appendix D: Cables - Storage Units - Controllers
Sample Configurations
The following sample configurations are for illustration only and may not be suitable for any specific customer installation. Contact your IBM Business Partner or IBM
Marketing Representative for assistance with your specific configuration requirements.
Netfinity EXP200 One Independent SCSI Bus
Netfinity EXP200 Two Independent SCSI Buses
To configure as a single 10 drive SCSI channel, attach one external cable
from the SCSI adapter to either the 1 IN or 2 IN connectors in the EXP200.
Set switch 1 to “Off” position.
To configure as two independent 5 drive SCSI channels, attach one
external cable from the SCSI adapter to the SCSI bus 1 IN connector in
the EXP200. Attach a second External SCSI cable from another SCSI
adapter, in the same or separate server, to the 2 IN connector in the
unit. Set switch 1 to “On” position.
Order:
SERVER
1 x 3530-1RU
Server SCSI
2 x External Cables*
Adapter
See Cables - Storage Units Server SCSI
Controllers section
Adapter
Up to 10 Disk Drives
19” Rack Space
Order:
1 x 3530-1RU
1 x External Cable*
See Cables - Storage Units Controllers section
Up to 10 Disk Drives
19” Rack Space
* One 2M Ultra2 cable is
included with each EXP200.
SERVER
Server SCSI
Adapter
External cable
(or)
* One 2M Ultra2 cable is
included with each EXP200.
Operational mode (SCSI
F/W, Ultra SCSI, Ultra2
SCSI) may be limited by
controller, cable or cable
length. See Appendix D
for additional information.
Standard Repeater Card
Switch 1
1 IN
Off
2 IN
1 IN
2 IN
External cables
Switch 1
On
Standard Repeater Card
Operational mode (SCSI
F/W, Ultra SCSI, Ultra-2
SCSI) may be limited by
controller, cable or cable
length, or hard disk drive
type. See Appendix D for
additional information.
IBM NETFINITY EXP200
1 2 3 4 5 6 7 8 910
1 2 3 4 5 6 7 8 910
Netfinity EXP200 One Independent SCSI Bus
High Availability Configuration
To configure a single 10 drive SCSI channel for clustering, attach one
external cable from the SCSI adapter in Node A to the 1 IN connector in
the EXP200. Connect a second external cable to a SCSI adapter in Node
B and to the 2 IN connector in the EXP200.
Node B
Order:
1 x 3530-1RU
2 x External Cables*
See Cables - Storage Units Controllers section
Up to 10 Disk Drives
19” Rack Space
* One 2M Ultra2 cable is
included with each EXP200.
Node A
Server SCSI
Adapter
Server SCSI
Adapter
Off
Standard Repeater Card
1 IN
2 IN
External cables
Switch1
Operational mode (SCSI
F/W, Ultra SCSI, Ultra-2
SCSI) may be limited by
controller, cable, or cable
length. See Appendix D
for additional information.
1 2 3 4 5 6 7 8 910
Updated 01/01/00
For the latest product & technical information, refer to the Information Sources on pages 1 and 2.
89
IBM Netfinity Fibre Channel Solutions
Netfinity Fibre Channel RAID Controller
Unit 35261RU
Standard Fibre
Channel RAID
Controller
Part Number
Netfinity Fibre Channel
Failsafe RAID Controller
Opt. (P/N 01K7296)
• Contains a single Short-Wave Fibre Connection (use cable group D)
and six female 0.8 mm Very High Density Connection Interface
(VHDCI) SCSI connectors (EXP15 - use cable group A)
• Hot-Swap Redundant Fans and Power Supplies
• Optional Netfinity Fibre Channel Failsafe RAID Controller
(P/N 01K7296) provides a redundant RAID controller and
second Short-Wave Fibre Connection (use cable group D).
• Attach directly to Netfinity Fibre Channel PCI Adapter(s)
(P/N 01K7297) or indirectly through Netfinity Fibre Channel
Hub (P/N 35231RU) using cables from cable group D
• Height is 4 U (1 U = 1.75 in or 44.45 mm)
• Requires Netfinity Enterprise Rack or Expansion Cabinet, Netfinity
Rack, Netfinity NetBAY22 or 19-inch EIA-D
Industry-Standard Rack. Mounting rails are included with the controller.
• For optimum performance no more than two RAID controller units
(P/N 35261RU) should be attached to a single hub (P/N 35231RU).
Description
35261RU
Netfinity Fibre Channel RAID Controller Unit
35231RU
Netfinity Fibre Channel Hub
01K7296
Netfinity Fibre Channel Failsafe RAID Controller
01K7297
Netfinity Fibre Channel PCI Adapter
Supported Cable Groups
Cable Group A (0.8 mm to 0.8 mm)
03K9310
Netfinity 2 M Ultra2 SCSI Cable
03K9311
Netfinity 4.2 M Ultra2 SCSI Cable
37L7101
Netfinity 20 M Ultra2 SCSI Cable
Cable Group D (Short-Wave Fibre)
03K9306
Netfinity Fibre Channel 5 M Cable
03K9305
Netfinity Fibre Channel 25 M Cable
Customer supplied short-wave cable of up to 500 meters (0.31 miles)
Netfinity Fibre Channel Hub 35231RU
Cable Group E (Long-Wave Fibre)
Customer supplied long-wave cable of up to 10 kilometers (6.2 miles)
GBIC
• Seven-port Fibre Channel Hub chassis
• Includes four standard Netfinity Fibre Channel Short-Wave GBIC’s
(GigaBit Interface Converters)
• GBIC’s supported
- Netfinity Fibre Channel Short-Wave GBIC (P/N 03K9308) which
supports Cable Group D
- Netfinity Fibre Channel Long-Wave GBIC (P/N 03K9307) which
supports Cable Group E
• Supported Attachments (up to seven, each requires a GBIC):
- Netfinity Fibre Channel PCI Adapter (P/N 01K7297), which requires
cable group D with short-wave GBIC
- Second Netfinity Fibre Channel Hub (P/N 35231RU) requires cable
group D or E with corresponding GBIC
- Netfinity Fibre Channel RAID Controller Unit 35261RU requires
cable group D and short-wave GBIC for each hub.
• Height is 1 U (1 U = 1.75 in or 44.45 mm). Two units can be mounted
side-by-side in a 1 U space.
• Requires Netfinity Enterprise Rack or Expansion Cabinet, Netfinity
Rack, NetBAY22 or 19-inch EIA-D
Industry-Standard Rack. Mounting hardware is included with the hub.
• For optimum performance no more than two RAID controller units
(P/N 35261RU) should be attached to a single hub (P/N 35231RU)
Netfinity Fibre Channel PCI Adapter
(P/N 01K7297)
Netfinity Fibre
Channel PCI Adapter
(P/N 01K7297)
03K9308
Netfinity Fibre Channel Short-Wave GBIC1
03K9307
Netfinity Fibre Channel Long-Wave GBIC
1. Four Netfinity Fibre Channel Short-Wave GBIC’s (P/N 03K9308) are included
with Netfinity Fibre Channel Hub (P/N 35231RU).
Configuration Examples - Cable Group ( )
1. Configured as two independent 5 HDD buses.
EXP15
RAID Unit (35261RU)
PCI Adapter
(01K7297)
(D)
PCI Adapter
(01K7297)
(D)
Std. RAID
Controller
EXP151
RAID Unit (35261RU)
Std. RAID
Controller
(D)
PCI Adapter
(01K7297)
(A)
Opt. Controller
(01K7296)
(A)
Installed in the same or separate hosts
• PCI to FCAL 64/32-bit host adapter
• Supported Attachments (use cable group D):
- Netfinity Fibre Channel Hub (P/N 35231RU), requires available
short-wave GBIC in hub
- Netfinity Fibre Channel RAID Controller Unit 35261RU
- Netfinity Fibre Channel Failsafe RAID Controller (P/N 01K7296)
RAID Unit (35261RU)
PCI Adapter
(01K7297)
(D)
(D)
(A)
HUB (35231RU)
(D)
(D) or (E - requires
GBIC’s 03K9307
PCI Adapter
(01K7297)
RAID Unit (35261RU)
HUB (35231RU)
PCI Adapter
(01K7297)
(D)
PCI Adapter
(01K7297)
(D)
(D)
(A)
HUB (35231RU)
90
(D)
EXP15
Std. RAID
Controller
RAID Unit (35261RU)
(D)
Std. RAID
Controller
PCI Adapter
(01K7297)
PCI Adapter
(01K7297)
EXP15
Std. RAID
Controller
(D)
Separate hosts designated by dashed lines
EXP151
Opt. Controller
(01K7296)
(A)
IBM NETFINITY FIBRE CHANNEL
SOLUTIONS
IBM Netfinity Fibre Channel Solutions
Note: The following sample configurations are for illustration only and may not be suitable for any specific customer installation. Contact your IBM Business
Partner or IBM Marketing Representative for assistance with your specific configuration requirements
High-speed single-node Netfinity Fibre Channel Storage configuration offering performance,
bandwidth & capacity
Netfinity Rack (P/N 9306900)
Netfinity Rack (P/N 9306900)
Tape Library Support
3570B2x - 6U
3570C2x - 6U
Monitor Compartment
(P/N 94G7444)
Short Wave
Fibre Cable
(Cable Group D)
G74 Monitor
(P/N 65474AN) (10U)
Four Port Console Selector Switch
(P/N 28L0542)
Keyboard Tray (P/N 28L4707) (2U)
Keyboard with TrackPoint
(P/N 28L3644)
Standard Fibre
Channel RAID
Controller
Netfinity Fibre Channel RAID
Controller Unit (P/N 35261RU)
- Height (4U)
- Six 0.8 mm VHDCI
Female Connectors
- LVDS
- Includes 19" Rack Installation
Hardware
Cable Selection
EXP15 - Cable Group A
Supported Storage Expansion Units
In Any Combination
(Up to six per 35261RU Controller)
Other Components
(Quantities will vary based
on specific configurations)
Rack
- Blank Filler Kits (P/N 94G6670)
- Power Cable (P/N 94G6667)
- Console Cable (P/N 94G7447)
- Side Panel Kit (P/N 94G6669)
- Rack Attachment Kit
(P/N 94G7446)
Netfinity EXP15 (P/N 35202RU)
- Height (3U)
- Up to 10 HDDs
- Two 0.8 mm VHDCI
Female Connectors
- Cable Group A
- Switch 1 "off"
Netfinity Fibre Channel
PCI Adapter
(P/N 01K7297)
Server Node A
Supported Servers
Netfinity 8500R (8U),
7000 M10 (11U)
5500, 5500 Mxx (8U)
5600 (5U)
5000 (5U)
UPS SU-3000RMB
(P/N 94G6676) (3U)
UPS SU-1400RMB
(P/N 94G6674) (3U)
UPS SU-3000RMB
(P/N 94G6676) (3U)
Connector Types
68-pin - High Density Connector
0.8 mm - Very High Density Connection Interface VHDCI
Cable Group D (Short-Wave Fibre)
03K9306 - Netfinity Fibre Channel 5 M Cable
03K9305 - Netfinity Fibre Channel 25 M Cable
Customer supplied short-wave cable of up to 500 meters (0.31 miles)
Cable Group A (0.8 mm to 0.8 mm)
03K9310 - Netfinity 2 M Ultra2 SCSI Cable
03K9311 - Netfinity 4.2 M Ultra2 SCSI Cable
37L7101- Netfinity 20 M Ultra2 SCSI Cable
Cable Group E (Long-Wave Fibre)
Customer supplied long-wave cable of up to 10 kilometers (6.2 miles)
GBIC
03K9308 - Netfinity Fibre Channel Short-Wave GBIC1
03K9307 - Netfinity Fibre Channel Long-Wave GBIC
1. Four Netfinity Fibre channel Short-Wave GBIC’s (P/N 03K9308)
are included with Netfinity Fibre Channel Hub (P/N 35231RU)
Updated 01/01/00
For the latest product & technical information, refer to the Information Sources on pages 1 and 2.
91
IBM Netfinity Fibre Channel Solutions
Note: The following sample configurations are for illustration only and may not be suitable for any specific customer installation. Contact your IBM Business Partner
or IBM Marketing Representative for assistance with your specific configuration requirements
High-speed single-node Netfinity Fibre Channel Storage configuration with Microsoft NT failover
support and RAID redundancy for availability, performance, capacity
Netfinity Rack (P/N 9306900)
Monitor Compartment
(P/N 94G7444)
Netfinity Rack (P/N 9306900)
Short Wave
Fibre Cable
(Cable Group D)
Tape Library Support
3570B2x - 6U
3570C2x - 6U
G74 Monitor
(P/N 65474AN) (10U)
Four Port Console Selector Switch
(P/N 28L0542)
Keyboard Tray (P/N 28L4707) (2U)
Keyboard with TrackPoint
(P/N 28L3644)
Standard Fibre
Channel RAID
Controller
Netfinity Fibre Channel
Failsafe RAID Controller
(P/N 01K7296)
Netfinity Fibre Channel RAID
Controller Unit (P/N 35261RU)
- Height (4U)
- Six 0.8 mm VHDCI
Female Connectors
- LVDS
- Includes 19" Rack Installation
Hardware
Cable Selection
EXP15 - Cable Group A
Supported Storage Expansion Units
In Any Combination
(Up to six per 35261RU Controller)
Netfinity Fibre Channel
PCI Adapter
(P/N 01K7297)
Other Components
(Quantities will vary based
on specific configurations)
Rack
- Blank Filler Kits (P/N 94G6670)
- Power Cable (P/N 94G6667)
- Console Cable (P/N 94G7447)
- Side Panel Kit (P/N 94G6669)
- Rack Attachment Kit
(P/N 94G7446)
Netfinity EXP15 (P/N 35202RU)
- Height (3U)
- Up to 10 HDDs
- Two 0.8 mm VHDCI
Female Connectors
- Cable Group A
- Switch 1 "off"
Netfinity Fibre Channel
PCI Adapter
(P/N 01K7297)
Server Node A
Supported Servers
Netfinity 8500R (8U),
7000 M10 (11U)
5500, 5500 Mxx (8U)
5600 (5U)
5000 (5U)
UPS SU-3000RMB
(P/N 94G6676) (3U)
UPS SU-1400RMB
(P/N 94G6674) (3U)
UPS SU-3000RMB
(P/N 94G6676) (3U)
Connector Types
68-pin - High Density Connector
0.8 mm - Very High Density Connection Interface VHDCI
Cable Group D (Short-Wave Fibre)
03K9306 - Netfinity Fibre Channel 5 M Cable
03K9305 - Netfinity Fibre Channel 25 M Cable
Customer supplied short-wave cable of up to 500 meters (0.31 miles)
Cable Group A (0.8 mm to 0.8 mm)
03K9310 - Netfinity 2 M Ultra2 SCSI Cable
03K9311 - Netfinity 4.2 M Ultra2 SCSI Cable
37L7101 - Netfinity 20 M Ultra2 SCSI Cable
Cable Group E (Long-Wave Fibre)
Customer supplied long-wave cable of up to 10 kilometers (6.2 miles)
GBIC
03K9308 - Netfinity Fibre Channel Short-Wave GBIC1
03K9307 - Netfinity Fibre Channel Long-Wave GBIC
1. Four Netfinity Fibre channel Short-Wave GBIC’s (P/N 03K9308)
are included with Netfinity Fibre Channel Hub (P/N 35231RU)
92
Note: The following sample configurations are for illustration only and may not be suitable for any specific customer installation. Contact your IBM Business Partner
or IBM Marketing Representative for assistance with your specific configuration requirements
Cluster Solution
High speed multiple node Microsoft Cluster Service (MSCS) and Netfinity Fibre Channel Storage configuration offering data protection and RAID
redundancy.
Netfinity Rack (P/N 9306900)
Monitor Compartment
(P/N 94G7444)
Netfinity Rack (P/N 9306900)
Short Wave
Fibre Cable
(Cable Group D)
Tape Library Support
3570B2x - 6U
3570C2x - 6U
G74 Monitor
(P/N 65474AN) (10U)
Public Lan
Four Port Console Selector Switch
(P/N 28L0542)
Keyboard Tray (P/N 28L4707) (2U)
Keyboard with TrackPoint
(P/N 28L3644)
25 ft. Ethernet
Crossover Cable2
Other Components
(Quantities may vary based
on specific configurations)
Rack
- Blank Filler Kits (P/N 94G6670)
- Power Cable (P/N 94G6667)
- Console Cable (P/N 94G7447)
- Side Panel Kit (P/N 94G6669)
- Rack Attachment Kit
(P/N 94G7446)
Server
- Each server requires two
identical HDDs for NOS
mirroring
Onboard or
Supported LAN
Adapter
Netfinity Fibre
Channel PCI Adapter
(P/N 01K7297)
Netfinity 10/100
Ethernet Adapter
(P/N 34L1501)
Onboard RAID or
ServeRAID-3x
(NOS Mirroring)
Standard Fibre
Channel RAID
Controller
Netfinity Fibre Channel
Failsafe RAID Controller
(P/N 01K7296)
Cable Selection
EXP15 - Cable Group A
Netfinity Fibre
Channel PCI Adapter
(P/N 01K7297)
Onboard or
Supported LAN
Adapter
Onboard RAID or
ServeRAID-3x
(NOS Mirroring)
Netfinity Fibre Channel RAID
Controller Unit (P/N 35261RU)
- Height (4U)
- Six 0.8 mm VHDCI
Female Connectors
- LVDS
- Includes 19" Rack Installation
Hardware
Mirrored Quorum Disks
Server Node B
Supported Servers
Netfinity 7000 M10 (11U)
5500, 5500 Mxx (8U)
5600 (5U))
5000 (5U)
Netfinity 10/100
Ethernet Adapter
(P/N 34L1501)
Netfinity Fibre Channel Hub
(P/N 35231RU) Qty. 1
- Height (1U)
- Includes Four Short Wave GBIC
- Three Open GBIC Sockets
- May install two Side-by-Side
- Includes 19" Rack Installation
Hardware
Supported Storage Expansion Units
In Any Combination
(Up to six per 35261RU Controller)
Netfinity EXP15 (P/N 35202RU)
- Height (3U)
- Up to 10 HDDs
- Two 0.8 mm VHDCI
Female Connectors
- Cable Group A
- Switch 1 "off"
Server Node A
Supported Servers
Netfinity 7000 M10 (11U)
5500, 5500 Mxx (8U)
5000 (5U)
UPS SU-3000RMB
(P/N 94G6676) (3U)
UPS SU-3000RMB
(P/N 94G6676) (3U)
Connector Types
68-pin - High Density Connector
0.8 mm - Very High Density Connection Interface VHDCI
UPS SU-3000RMB
(P/N 94G6676) (3U)
UPS SU-3000RMB
(P/N 94G6676) (3U)
Cable Group D (Short-Wave Fibre)
03K9306 - Netfinity Fibre Channel 5 M Cable
03K9305 - Netfinity Fibre Channel 25 M Cable
Customer supplied short-wave cable of up to 500 meters (0.31 miles)
Cable Group E (Long-Wave Fibre)
Customer supplied long-wave cable of up to 10 kilometers (6.2 miles)
Cable Group A (0.8 mm to 0.8 mm)
03K9310 - Netfinity 2 M Ultra2 SCSI Cable
03K9311 - Netfinity 4.2 M Ultra2 SCSI Cable
37L7101 - Netfinity 20 M Ultra2 SCSI Cable
GBIC
03K9308 - Netfinity Fibre Channel Short-Wave GBIC1
03K9307 - Netfinity Fibre Channel Long-Wave GBIC
1. Four Netfinity Fibre channel Short-Wave GBIC’s (P/N 03K9308)
are included with Netfinity Fibre Channel Hub (P/N 35231RU)
2. Microsoft Cluster Server (MSCS) requires a private interconnect
between clustered nodes. A 25 ft. Ethernet crossover cable is
shown but not available from IBM as a separate option. Contact
your IBM Business Partner for assistance.
Updated 01/01/00
For the latest product & technical information, refer to the Information Sources on pages 1 and 2.
93
IBM NETFINITY FIBRE CHANNEL
SOLUTIONS
IBM Netfinity Fibre Channel Solutions
IBM Netfinity Fibre Channel Solutions
Note: The following sample configurations are for illustration only and may not be suitable for any specific customer installation. Contact your IBM Business Partne
or IBM Marketing Representative for assistance with your specific configuration requirements
Advanced high-speed high-availability multiple node Microsoft Cluster Service (MSCS) and fully
redundant Netfinity Fibre Channel Storage configuration offering the highest levels of data
protection and availability and access to data
Netfinity Rack (P/N 9306900)
Monitor Compartment
(P/N 94G7444)
Short Wave
Fibre Cable
(Cable Group D)
Public Lan
See Other Components-
Netfinity Rack (P/N 9306900)
Tape Library Support
3570B2x - 6U
3570C2x - 6U
G74 Monitor
(P/N 65474AN) (10U)
Server
Four Port Console Selector Switch
(P/N 28L0542)
Keyboard Tray (P/N 28L4707) (2U)
Keyboard with TrackPoint
(P/N 28L3644)
Netfinity 10/100
Ethernet PCI Adapter 2
(P/N 34L1501)
25 ft. Ethernet
Crossover
Cable2
Onboard RAID or
ServeRAID-3x
(NOS Mirroring)
Netfinity Fibre Channel
Failsafe RAID Controller
(P/N 01K7296)
Netfinity Fibre
Channel PCI Adapter
(P/N 01K7297)
Netfinity Fibre Channel
PCI Adapter
(P/N 01K7297)
Server Node B
Supported Servers
Netfinity 7000 M10 (11U)
5500, 5500 Mxx (8U)
5000 (5U)
Netfinity 10/100
Ethernet PCI Adapter 2
(P/N 34L1501)
Standard Fibre
Channel RAID
Controller
Cable Selection
EXP15 - Cable Group A
Connector Types
68-pin - High Density Connector
0.8 mm - Very High Density Connection Interface VHDCI
Netfinity Fibre Channel RAID
Controller Unit (P/N 35261RU)
- Height (4U)
- Six 0.8 mm VHDCI
Female Connectors
- LVDS
- Includes 19" Rack Installation
Hardware
Mirrored Quorum Disks
Supported Storage Expansion Units
In Any Combination
(Up to six per 35261RU Controller)
Netfinity EXP15 (P/N 35202RU)
- Height (3U)
- Up to 10 HDDs
- Two 0.8 mm VHDCI
Female Connectors
- Cable Group A
- Switch 1 "off"
Netfinity Fibre
Channel PCI Adapter
(P/N 01K7297)
Onboard RAID or
Netfinity Fibre
Other Components
Channel PCI Adapter
ServeRAID-3x
(Quantities may vary based
(NOS
Mirroring)
(P/N
01K7297)
on specific configurations)
Rack
Server Node A
- Blank Filler Kits (P/N 94G6670)
Supported Servers
- Power Cable (P/N 94G6667)
Netfinity 7000 M10 (11U)
- Console Cable (P/N 94G7447)
5500, 5500 Mxx (8U)
- Side Panel Kit (P/N 94G6669)
5000 (5U)
- Rack Attachment Kit
(P/N 94G7446)
UPS SU-3000RMB
Server
(P/N 94G6676) (3U)
- Each server requires two
identical HDDs for NOS
mirroring
UPS SU-3000RMB
- Public LAN access through an
(P/N 94G6676) (3U)
onboard or supported LAN
adapter
Netfinity Fibre Channel Hub
(P/N 35231RU) Qty. 2
- Height (1U)
- Includes Four Short Wave GBIC’s
- Three Open GBIC Sockets
- Two installed Side-by-Side
- Includes 19" Rack Installation
Hardware
UPS SU-3000RMB
(P/N 94G6676) (3U)
UPS SU-3000RMB
(P/N 94G6676) (3U)
Cable Group D (Short-Wave Fibre)
03K9306 - Netfinity Fibre Channel 5 M Cable
03K9305 - Netfinity Fibre Channel 25 M Cable
Customer supplied short-wave cable of up to 500 meters (0.31 miles)
Cable Group E (Long-Wave Fibre)
Customer supplied long-wave cable of up to 10 kilometers (6.2 miles)
Cable Group A (0.8 mm to 0.8 mm)
03K9310 - Netfinity 2 M Ultra2 SCSI Cable
03K9311 - Netfinity 4.2 M Ultra2 SCSI Cable
37L7101 - Netfinity 20 M Ultra2 SCSI Cable
GBIC
03K9308 - Netfinity Fibre Channel Short-Wave GBIC1
03K9307 - Netfinity Fibre Channel Long-Wave GBIC
1. Four Netfinity Fibre channel Short-Wave GBIC’s (P/N 03K9308)
are included with Netfinity Fibre Channel Hub (P/N 35231RU)
2. Microsoft Cluster Server (MSCS) requires a private interconnect
between clustered nodes. A 25 ft. Ethernet crossover cable is
shown but not available from IBM as a separate option. Contact
your IBM Business Partner for assistance.
94
Netfinity SP Switch (P/N 35291RY)2
Note: - The following sample configurations are for illustration only and may not be suitable for any specific customer installation.
- Contact your IBM Business Partner or IBM Marketing Representative for assistance with your specific configuration
requirements.
• Eight Ports Standard
• Cable Group H
• Height 2U
AdditionalPower
Supply (P/N 09L5403)
Netfinity Advanced System Management
Interconnect Cable Kit (P/N 03K9309)
SAN Fibre Channel Switch(P/N 2109S16)
Cluster Interconnect
Cable Group H
PCI Slot 7
Onboard Advanced
System Management
Adapter
Netfinity SP PCI Host
Adapter (P/N 01K7305)
Node 1
Node 2
Node 3
Node 4
Node 5
Node 6
Node 7
Node 8
Public
LAN
SAN Fibre Channel Switch
2109-S16- Qty. 2
SAN Fibre Channel Switch (P/N 2109S16)
Netfinity 10/100
Ethernet PCI Adapter 2
(P/N 34L1501)1
Processors:
3 x P/N 28L4733
Cable Group D2
AdditionalPower
Supply (P/N
09L5403)
PCI Slot 6
Memory:
1 x P/N 01K8046
Node 1
Node 2
Node 3
Node 4
Node 5
Node 6
Node 7
Node 8
Node 1
Node 2
Node 3
Node 4
Node 5
Node 6
Node 7
Node 8
PCI Slot 4
Netfinity Fibre Channel
PCI Adapter
(P/N 01K7297)
PCI Slot 3
Cable Group D2
Standard Fibre
Channel RAID
Controller
Netfinity Fibre Channel
PCI Adapter
(P/N 01K7297)
Netfinity Fibre Channel
Failsafe RAID Controller
(P/N 01K7296)
PCI Slot 1
Mirrored Hot-Swap
2x
P/N 36L9806
ServeRAID-3L
Ultra2 SCSI Adapter
(P/N 01K7364)2
Server Nodes 1... 8
Netfinity 7000 M10 8680-6RY
RAID 5
Minimum 3 HDDs
plus
1 Hot-spare
- Height (2U)
-- Includes Four Short Wave
GBICs / Switch
- Includes 19" Rack
Installation Hardware
Optional Short Wave
GBICs (P/N 03K9308).
-Optional Additional Powe
Supply (P/N 09L5403
Netfinity Fibre
Channel RAID
Controller Unit
(P/N 35261RU)
- Height (4U)
- Six 0.8 mm VHDCI
Female Connectors
- Ultra2 SCSI
- Includes 19" Rack
Installation Hardware
Cable Group A2
Mirrored
Quorum
Disks
Single Occurance Option
(Any node 1...8)
IBM
PCI tape controller
included with 3502R14
Optional
3502R14 DLT Tape Library
1. Onboard or supported LAN adapter.
2. ServeRAID-3H or 3HB may also be used.
Rack A
EXP15
EXP15
7000 M10
7000 M10
3000 UPS
3000 UPS
Updated 01/01/00
Rack B
Console Sw
SP Switch
Fibre Switch
EXP15
EXP15
7000 M10
7000 M10
3000 UPS
3000 UPS
Rack C
Monitor
Console Sw.
EXP15
7000 M10
Keyboard
7000 M10
3000 UPS
3000 UPS
Rack D
RAID Controller
3502 Tape Lib
EXP15
7000 M10
7000 m10
3000 UPS
3000 UPS
Netfinity EXP15 (P/N
3520-2RU)
- Height (3U)
- Up to 10 HDDs
(Example: 10 x 18.2 GB P/N
36L9810)
- Two 0.8 mm VHDCI Female
Connectors
- Up to six (>1 Terabyte) per
35261RU
- Cable Group A
(Ultra2 0.8 - 0.8mm)
Connector Types
0.8 mm - Very High Density Connection Interface VHDCI (1) Four Fibre Channel Short-Wave GBICs are included with
SAN Fibre Channel Switch 2109-S16
Cable Group A (0.8 mm to 0.8 mm)
(2) Cable length requirements are dependant on component
03K9310 - Netfinity 2 M Ultra2 SCSI Cable
placement within the rack suite. The parts list for this example
03K9311 - Netfinity 4.2 M Ultra2 SCSI Cable
reflects requirements for the illustrated configuration only.
037L7101 - Netfinity 20 M Ultra2 SCSI Cable
Cable length requirements for other configurations are best
determined by using the Netfinity Rack Configurator which is
Cable Group D (Short-Wave Fibre)
downloadable from Web site www.ibm.com/pc/us/products/
03K9306 - Netfinity Fibre Channel 5 M Cable
server/download.html
03K9305 - Netfinity Fibre Channel 25 M Cable
(3) A tape library is optional and attaches to any one of the
Customer supplied short-wave cable of up to 500
nodes within the cluster.
meters (0.31 miles)
Additional Information and Configuration
.
GBIC
Tools Available
03K9308 - Netfinity Fibre Channel Short-Wave GBIC 1
See "Information Sources" section for Clustering, Server Paper
Configurator, ConfigXpert and Netfinity Rack Configurator
03K9307 - Netfinity Fibre Channel Long-Wave GBIC
URLs
Cable Group H
03K9220-Netfinity SP 2.3M Cable
03K9221- Netfinity SP 5.0M Cable
03K9222- Netfinity SP 10.0M Cable
For the latest product & technical information, refer to the Information Sources on pages 1 and 2.
95
IBM NETFINITY FIBRE CHANNEL
SOLUTIONS
Netfinity Availability Extensions for MSCS
Eight Node Cluster
Netfinity Availability Extensions for MSCS
Eight Node Cluster - Parts List1
Note: The following sample configurations are for illustration only and may not be suitable for any specific customer installation. Contact your IBM Business
Partner or IBM Marketing Representative for assistance with your specific configuration requirements.
Part
Number
Description
Qty.
Usage
8680-6RY Netfinity 7000 M10
8
Cluster Nodes
01K8046
Netfinity 7000 M10 1 GB Memory Expansion Kit - 4x256
8
Total of 1280 MB per node. Acceptable range is 1 to 4 GB
28L4733
Netfinity 7000 M10 500 MHz/512KB Upgrade with Pentium
III Xeon Processor
24
3 per node, total of 4 SMP processors per node
36L9806
Netfinity 9.1 GB 10K-3 Wide Ultra SCSI Hot-Swap SL HDD
16
2 per node, mirrored NOS, attached to ServeRAID-3L
01K7364
Netfinity ServeRAID-3L Ultra2 SCSI Adapter
8
1 per node for NOS HDDs. Install in PCI slot 1.
34L1501
Netfinity 10/100 Ethernet PCI Adapter 2
8
Public LAN - slot 6
01K7297
Netfinity Fibre Channel PCI Adapter
16
2 per node, each attaches to one of the two Fibre Hubs. Install in PCI slots 3
and 4.
01K7951
Netfinity 400 W Hot-Swap Redundant Power Supply II
8
1 per node, provides power supply redundancy for each node
03K9309
Netfinity Advanced System Management Interconnect
Cable Kit
8
Provides attachment for remote system management for 8 nodes and SP
Switch
02K6545
UltraSlim 56 W AC Adapter
8
Provides an independent backup power source for systems management
2
Redundant short-wave (SW) connections from each of eight nodes to Netfinity
Fibre Channel RAID Controller Unit. Each switch includes four standard SW
GBICs.
Hot-Swap redundant power supply for SAN Fibre Channel Switch
Storage Subsystems
2109S16
SAN Fibre Channel Switch
09L5403
Additional Power Supply
2
03K9308
Netfinity Fibre Channel Short-Wave GBIC
10
35261RU
Netfinity Fibre Channel RAID Controller Unit
1
Attaches to six EXP15's, with Failsafe Controller - two attachments to the hubs
01K7296
Netfinity Fibre Channel Failsafe RAID Controller
1
Installs in Controller Unit, provides redundant path to EXP15s
35202RU
Netfinity EXP15
6
One LVDS attachment to RAID Controller Unit per EXP15, max of 60 HDDs
36L9811
Netfinity EXP 36.4 GB 10K-3 Wide Ultra SCSI Hot-Swap
HDD
58
A minimum of four RAID 5 HDDs (3 plus a hot-spare) with a maximum of 58
38L9809
Netfinity EXP 9.1 GB 10K-3 Wide Ultra SCSI Hot-Swap HDD
2
Mirrored quorum HDDs
3502R14
DLT Tape Library
1
Tape subsystems are optional. The 3502R14 includes a 3 M cable and PCI
controller.
94G6676
APC Smart-UPS 3000RMB
8
Power connections are intra-rack only2
03K9306
Netfinity Fibre Channel 5 M Cable
20
16 node to hub, 2 hub to hub, 2 hub to RAID controllers
03K9310
Netfinity 2 M Ultra2 SCSI Cable
2
RAID controller to EXP15s
03K9311
Netfinity 4.2 M Ultra2 SCSI Cable
4
RAID controller to EXP15s
Storage Cables
Netfinity SP Switch
01K7305
Netfinity SP PCI Host Adapter
8
1 per node for cluster interconnect
35291RY
Netfinity SP Switch (2U)
1
Standard configuration supports interconnection of up to 8 nodes.
03K9221
Netfinity SP 5.0 M Cable
8
1 per node for cluster interconnect
03K9309
Netfinity Advanced System Management Interconnect
Cable Kit
1
Allows SP Switch attachment to 8 node systems management network
8
Provides interconnection between Advanced System Management Adapters.
Includes TrackPoint
Other Non-Rack
Customer
Ethernet System Management Cables
Supplied
28L3644
Space Saver II Keyboard (1U)
1
65464AN
G54 Color Monitor 15" (13.7" Viewable Image Size)
1
-
Rack / Related
96
9306900
Netfinity Rack Cabinet
4
Provides 42U of mounting space per rack
28L4707
Netfinity Rack Keyboard Tray
1
Allows keyboard 28L3640 to be stowed in a ready to use position
Required for mounting 8271 switch in a Netfinity rack
85H6735
Network Products Mounting Kit
1
94G7444
Monitor Compartment
1
Required for mounting G54 Monitor
28L0542
Netfinity Console Selector Switch (4-port)
1
Connects 3 nodes to 8-port switch
94G7445
Console Server Selector Switch (8-port)
1
Connects 5 nodes and 4-port switch to monitor and keyboard
94G6669
Side Panel Kit
1
Provides side panels for both ends of the rack suite.
94G7442
Fixed Shelf
1
Required for installation of 3502R14 tape library.
Rack Attachment Kit
3
94G6670
Blank Filler Panel Kit
3
Provides hardware for attaching four racks together in a suite
Provides blank panels to fill the remaining rack space within the suite
94G6667
Power Cable - Type A14
10
Provides 14' power cables for UPS attachment to installed components
94G7447
12ft. Console Cable Set
9
Attaches each node to the console switch.
Netfinity Availability Extensions for
MSCS3
36L9891
Netfinity Availability Extensions for MSCS (3 node)
1
Includes an initial 3 node license and installation.
36L9892
Netfinity Availabilty Extensions for MSCS (1 node)
5
Includes an additional single node license and installation for 5 nodes.
1. Cable, power, cooling and weight are dependent on component placement within the rack and rack suite. This parts list reflects one possible configuration of the listed components. Prior
to ordering, you should configure your specific environment using the Netfinity Rack Configurator. The Netfinity Rack Configura tor is downloadable from URL
http:/www.ibm.com/pc/us/products/server/download.html.
2. Pre-installation site planning information: 94G6676 contains eight L5-30P, 120V 30 amp circuitry.
3. Consists of Netfinity Availability Extensions for MSCS software licenses (support for up to eight nodes) and installation services for the complete Netfinity solution being installed. Netfinity
Availabilty Extensions for MSCS is available through IBM Direct as a solution offering and is designed for installation by trained service personnel. Please contact your IBM representative for
ordering information.
Updated 01/01/00
For the latest product & technical information, refer to the Information Sources on pages 1 and 2.
97
IBM NETFINITY FIBRE CHANNEL
SOLUTIONS
94G7446
Netfinity Cluster Enabler for OPS
Eight Node Cluster
Netfinity SP Switch (P/N 35291RY)2
• Eight Ports Standard
Note: - The following sample configurations are for illustration only and may not be suitable for any specific customer installation.
Customer specific Oracle Parallel Server configurations require IBM testing and approval prior to installation. Contact your IBM
Business Partner or IBM Marketing Representative for assistance with your specific configuration requirements.
• Cable Group H
• Height 2U
Additional Power
Supply (P/N 09L5403)
Netfinity Advanced System Management
Interconnect Cable Kit (P/N 03K9309)
SAN Fibre Channel Switch(P/N 2109S16)
Cluster Interconnect
Cable Group H
PCI Slot 7
Onboard Advanced
System Management
Adapter
Netfinity SP PCI Host
Adapter (P/N 01K7305)
Node 1
Node 2
Node 3
Node 4
Node 5
Node 6
Node 7
Node 8
Node 1
Node 2
Node 3
Node 4
Node 5
Node 6
Node 7
Node 8
Public
LAN
Additional Power
Supply (P/N 09L5403)
Netfinity 10/100
Ethernet PCI Adapter 2
(P/N 34L1501)1
Processors:
3 x P/N 28L4733
SAN Fibre Channel Switch
2109-S16- Qty. 2
SAN Fibre Channel Switch (P/N 210-S16 )
PCI Slot 6
Memory:
1 x P/N 01K8046
Cable Group D2
Node 1
Node 2
Node 3
Node 4
Node 5
Node 6
Node 7
Node 8
PCI Slot 4
Netfinity Fibre Channel
PCI Adapter
(P/N 01K7297
PCI Slot 3
Cable Group D2
Standard Fibre
Channel RAID
Controller
Netfinity Fibre Channel
PCI Adapter
(P/N 01K7297
Netfinity Fibre Channel
Failsafe RAID Controller
(P/N 01K7296)
PCI Slot 1
Mirrored Hot-Swap
2x
P/N 36L9806
ServeRAID-3L
Ultra2 SCSI Adapter
(P/N 01K7364)2
Server Nodes 1... 8
Netfinity 7000 M10 8680-6RY
RAID 5
Minimum 3 HDDs
plus
1 Hot-spare
- Height (2U)
-- Includes Four Short Wave
GBICs / Switch
- Includes 19" Rack
Installation Hardware
Optional Short Wave
GBICs (P/N 03K9308).
-Optional Additional Power
Supply (P/N 09L5403)
Netfinity Fibre
Channel RAID
Controller Unit
(P/N 3526-1RU)
- Height (4U)
- Six 0.8 mm VHDCI
Female Connectors
- Ultra2 SCSI
- Includes 19" Rack
Installation Hardware
Cable Group A2
Single Occurance Option
(Any node 1...8)
IBM
PCI tape controller
included with 3502R14
1. Onboard or supported LAN adapter.
2. ServeRAID-3H or 3HB may also be used.
Optional
3502R14 DLT Tape Library
Connector Types
0.8 mm - Very High Density Connection Interface
VHDCI
Cable Group A (0.8 mm to 0.8 mm)
03K9310 - Netfinity 2 M Ultra2 SCSI Cable
03K9311 - Netfinity 4.2 M Ultra2 SCSI Cable
037L7101 - Netfinity 20 M Ultra2 SCSI Cable
Rack A
EXP15
EXP15
7000 M10
7000 M10
3000 UPS
3000 UPS
98
Rack B
Console Sw
SP Switch
Fibre Switch
EXP15
EXP15
7000 M10
7000 M10
3000 UPS
3000 UPS
Rack C
Monitor
Console Sw.
EXP15
7000 M10
Keyboard
7000 M10
3000 UPS
3000 UPS
Rack D
RAID Controller
3502 Tape Lib
EXP15
7000 M10
7000 m10
3000 UPS
3000 UPS
Cable Group D (Short-Wave Fibre)
03K9306 - Netfinity Fibre Channel 5 M Cable
03K9305 - Netfinity Fibre Channel 25 M Cable
Customer supplied short-wave cable of up to 500
meters (0.31 miles)
.
GBIC
03K9308 - Netfinity Fibre Channel Short-Wave GBIC1
03K9307 - Netfinity Fibre Channel Long-Wave GBIC
Cable Group H
03K9220-Netfinity SP 2.3M Cable
03K9221- Netfinity SP 5.0M Cable
03K9222- Netfinity SP 10.0M Cable
Netfinity EXP15 (P/N
3520-2RU)
- Height (3U)
- Up to 10 HDDs
(Example: 10 x 18.2 GB P/N
36L9810)
- Two 0.8 mm VHDCI Female
Connectors
- Up to six (>1 Terabyte) per
35261RU
- Cable Group A
(Ultra2 0.8 - 0.8mm)
(1) Four Fibre Channel Short-Wave GBICs are included with
SAN Fibre Channel Switch 2109-S16
(2) Cable length requirements are dependant on component
placement within the rack suite. The parts list for this
example reflects requirements for the illustrated configuration
only. Cable length requirements for other configurations are
best determined by using the Netfinity Rack Configurator
which is downloadable from Web site www.ibm.com/pc/us/
products/server/download.html
(3) A tape library is optional and attaches to any one of the
nodes within the cluster.
Additional Information and Configuration
Tools Available
See "Information Sources" section for Clustering, Server
Paper Configurator, ConfigXpert and Netfinity Rack
Configurator URLs
Note: - The following sample configurations are for illustration only and may not be suitable for any specific customer installation. Customer specific Oracle Parallel Server configurations
require IBM testing and approval prior to installation. Contact your IBM Business Partner or IBM Marketing Representative for assistance with your specific configuration requirements.
Part
Number
Description
Qty.
Usage
8680-6RY Netfinity 7000 M10
8
Cluster Nodes
01K8046
Netfinity 7000 M10 1 GB Memory Expansion Kit - 4x256
8
Total of 1280 MB per node. Acceptable range is 1 to 4 GB
28L4733
Netfinity 7000 M10 500 MHz/512KB Upgrade with Pentium
III Xeon Processor
24
3 per node, total of 4 SMP processors per node
36L9806
Netfinity 9.1 GB 10K-3 Wide Ultra SCSI Hot-Swap SL HDD
16
2 per node, mirrored NOS, attached to ServeRAID-3L
01K7364
Netfinity ServeRAID-3L Ultra2 SCSI Adapter
8
1 per node for NOS HDDs. Install in PCI slot 1.
34L1501
Netfinity 10/100 Ethernet PCI Adapter 2
8
Public LAN - slot 6
01K7297
Netfinity Fibre Channel PCI Adapter
16
2 per node, each attaches to one of the two Fibre Hubs. Install in PCI slots 3
and 4.
01K7951
Netfinity 400 W Hot-Swap Redundant Power Supply II
8
1 per node, provides power supply redundancy for each node
03K9309
Netfinity Advanced System Management Interconnect
Cable Kit
8
Provides attachment for remote system management for 8 nodes and SP
Switch.
02K6545
UltraSlim 56 W AC Adapter
8
Provides an independent backup power source for systems management
2
Redundant short-wave (SW) connections from each of eight nodes to Netfinity
Fibre Channel RAID Controller Unit. Each switch includes four standard SW
GBICs.
Hot-Swap redundant power supply for SAN Fibre Channel Switch
Storage Subsystems
2109S16
SAN Fibre Channel Switch
09L5403
Additional Power Supply
2
03K9308
Netfinity Fibre Channel Short-Wave GBIC
10
35261RU
Netfinity Fibre Channel RAID Controller Unit
1
Attaches to six EXP15's, with Failsafe Controller - two attachments to the hubs
01K7296
Netfinity Fibre Channel Failsafe RAID Controller
1
Installs in Controller Unit, provides redundant path to EXP15s
35202RU
Netfinity EXP15
6
One LVDS attachment to RAID Controller Unit per EXP15, max of 60 HDDs
36L9811
Netfinity EXP 36.4 GB 10K-3 Wide Ultra SCSI Hot-Swap
HDD
60
A minimum of four RAID 5 HDDs (3 plus a hot-spare) with a maximum of 60
3502R14
DLT Tape Library
1
Tape subsystems are optional. The 3502R14 includes a 3 M cable and PCI
controller.
94G6676
APC Smart-UPS 3000RMB
8
Power connections are intra-rack only2
16 node to hub, 2 hub to hub, 2 hub to RAID controllers
Storage Cables
03K9306
Netfinity Fibre Channel 5 M Cable
20
03K9310
Netfinity 2 M Ultra2 SCSI Cable
2
RAID controller to EXP15s
03K9311
Netfinity 4.2 M Ultra2 SCSI Cable
4
RAID controller to EXP15s
01K7305
Netfinity SP PCI Host Adapter
8
1 per node for cluster interconnect
35291RY
Netfinity SP Switch (2U)
1
Standard configuration supports interconnection of up to 8 nodes.
Netfinity SP Switch
03K9221
Netfinity SP 5.0 M Cable
8
1 per node for cluster interconnect
03K9309
Netfinity Advanced System Management Interconnect
Cable Kit
1
Allows SP Switch attachment to 8 node systems management network
Other Non-Rack
Customer
Ethernet System Management Cables
Supplied
8
Provides interconnection between Advanced System Management Adapters.
28L3644
Space Saver II Keyboard (1U)
1
Includes TrackPoint
65464AN
G54 Color Monitor 15" (13.7" Viewable Image Size)
1
-
Rack / Related
9306900
Netfinity Rack Cabinet
4
Provides 42U of mounting space per rack
28L4707
Netfinity Rack Keyboard Tray
1
Allows keyboard 28L3640 to be stowed in a ready to use position
85H6735
Network Products Mounting Kit
1
Required for mounting 8271 switch in a Netfinity rack
94G7444
Monitor Compartment
1
Required for mounting G54 Monitor
28L0542
Netfinity Console Selector Switch (4-port)
1
Connects 3 nodes to 8-port switch
94G7445
Console Server Selector Switch (8-port)
1
Connects 5 nodes and 4-port switch to monitor and keyboard
94G6669
Side Panel Kit
1
Provides side panels for both ends of the rack suite.
94G7442
Fixed Shelf
1
Required for installation of 3502R14 tape library.
94G7446
Rack Attachment Kit
3
Provides hardware for attaching four racks together in a suite
Updated 01/01/00
For the latest product & technical information, refer to the Information Sources on pages 1 and 2.
99
IBM NETFINITY FIBRE CHANNEL
SOLUTIONS
Netfinity Cluster Enabler for OPS
Eight Node Cluster - Parts List1
94G6670
Blank Filler Panel Kit
3
94G6667
Power Cable - Type A14
10
Provides blank panels to fill the remaining rack space within the suite
Provides 14' power cables for UPS attachment to installed components
94G7447
12ft. Console Cable Set
9
Attaches each node to the console switch.
36L9893
Netfinity Cluster Enabler for OPS (4 node)
1
Includes an initial 4 node license and installation.
36L9894
Netfinity Cluster Enabler for OPS (2 node)
2
Includes additional licenses and installation for four nodes.
Netfinity Cluster Enabler for OPS3
1. Cable, power, cooling and weight are dependent on component placement within the rack and rack suite. This parts list reflects one possible configuration of the listed components.
Prior to ordering, you should configure your specific environment using the Netfinity Rack Configurator. The Netfinity Rack Configurator is downloadable from URL
http:/www.ibm.com/pc/us/products/server/download.html
2. Pre-installation site planning information: 94G6676 contains eight L5-30P, 120V 30 amp circuitry.
3. Consists of several components distinct from the OPS application. It includes Netfinity Cluster Enabler for OPS software licenses (support for up to eight nodes) and installation services
for the complete Netfinity solution being installed. Netfinity Cluster Enabler for OPS is available through IBM Direct as a solution offering and is designed for installation by trained service
personnel. Please contact your IBM representative for ordering information.
100
IBM NETFINITY FIBRE CHANNEL
SOLUTIONS
Updated 01/01/00
For the latest product & technical information, refer to the Information Sources on pages 1 and 2.
101
IBM Netfinity SP Switch Eight Node Cluster
IBM DB2 Universal Database Enterprise-Extended Edition
Note: - The following sample configurations are for illustration only and may not be suitable for any specific customer installation. Contact your IBM Business Partner or IBM Marketing
Representative for assistance with your specific configuration requirements.
Netfinity Advanced System
Managememt Interconnect
Cable Kit (P/N 03K9309)
Public LAN
Memory
1x
(P/N 01K8046)
Processors:
1x
(P/N 28L4733)
Netfinity 10/100
Ethernet PCI Adapter 2
(P/N 34L1501)
(Channel 3)
Mirrored
Hot-Swap HDD
2 X (P/N 36L9806)
•Eight Ports Standard
•Up to 14 Ports
•Cable Group H
•Height 2U
Node 1
Node 2
Node 3
Node 4
Node 5
Node 6
Node 7
Node 8
Onboard Advanced
System Management
Adapter
Netfinity SP PCI
Host Adapter
(P/N 01K7305
Netfinity SP Switch (P/N 35291RY)2
Cluster Interconnect
Cable Group H
ServerRAID-3HB
Ultra2 SCSI Adapter
(P/N 37L6086)
Netfinity SP Switch Card Option
(P/N 01K7306)
•Includes cables for cascading to
standard switch card
•Required for addition of nodes 9-14
•Cable Group H
RAID 5
Minimum 3
HDDs plus
1 hot-spare
Cable
Group A
Server Nodes 1... 8
Netfinity 7000 M10
8680-1SY
Netfinity EXP15 (P/N 3520-2RU)
•Height 3U
•Up to 10 HDDs
•Two 0.8 mm VHDCI female connectors
•Cable group A (Ultra2 0.8 -0.8 mm)
1. Any supported LAN adapter.
2. With the Netfinity SP Switch Card option installed, the
Netfinity SP Switch can support a configuration of up to 14
nodes. Only an eight node cluster is shown here.
Connector Types
0.8 mm - Very High Density Connection Interface VHDCI
Cable Group A (0.8 mm to 0.8 mm)
03K9310 - Netfinity 2 M Ultra2 SCSI Cable
03K9311 - Netfinity 4.2 M Ultra2 SCSI Cable
37L7101 - Netfinity 20 M Ultra2 SCSI Cable
Cable Group H
03K9220 - Netfinity SP 2.3 M Cable
03K9221 - Netfinity SP 5.0 M Cable
03K9222 - Netfinity SP 10.0 M Cable
.Additional Information and Configuration Tools
See "Information Sources" section for Clustering, Server Paper
Configurator, ConfigXpert and Netfinity Rack Configurator URLs
Rack A
EXP15
EXP15
7000 M10
7000 M10
3000 UPS
3000 UPS
102
Rack B
35291RY Switch
EXP15
EXP15
7000 M10
7000 M10
3000 UPS
3000 UPS
Rack C
EXP15
EXP15
7000 M10
Keyboard and
Monitor
Console Sw
7000 M10
3000 UPS
3000 UPS
Rack D
EXP15
EXP15
7000 M10
7000 M10
3000 UPS
3000 UPS
IBM NETFINITY FIBRE CHANNEL
SOLUTIONS
IBM Netfinity SP Switch Eight Node Cluster
IBM DB2 Universal Database Enterprise-Extended Edition
Parts List1
Note: The following sample configurations are for illustration only and may not be suitable for any specific customer installation. Contact your IBM Business
Partner or IBM Marketing Representative for assistance with your specific configuration requirements.
Part
Number
Description
Qty.
Usage
8680-1SY
Netfinity 7000 M10
8
01K8046
Netfinity 7000 M10 1 GB Memory Expansion Kit - 4x256
8
Cluster Nodes
Total of 1280 MB per node. Acceptable range is 1 to 4 GB
33L5107
Netfinity 550 MHz/512 KB Upgrade with Pentium III Xeon
Processor
8
1 per node, total of 2 SMP processors per node
36L9806
Netfinity 9.1 GB 10K-3 Wide Ultra SCSI Hot-Swap SL HDD
16
2 per node, mirrored NOS, attached to ServeRAID-3L
37L6086
Netfinity ServeRAID-3HB Ultra2 SCSI Adapter
8
1 per node for NOS HDDs (channel3) and EXP15 external storage
34L1501
Netfinity 10/100 Ethernet PCI Adapter 2
8
1 per node for public LAN
01K7951
Netfinity 400 W Hot-Swap Redundant Power Supply II
8
1 per node, provides power supply redundancy for each node
03K9309
Netfinity Advanced System Management Interconnect
Cable Kit
8
Provides attachment for remote system management
02K6545
UltraSlim 56 W AC Adapter
8
Provides an independent backup power source for systems management
94G6676
APC Smart-UPS 3000RMB
8
Power connections are intra-rack only2
35202RU
Netfinity EXP15
8
One LVDS attachment per EXP15 to ServeRAID-3HB in respective servers
36L9810
Netfinity EXP 18.2 GB 10K-3 Wide Ultra SCSI Hot-Swap
HDD
80
Maximum of 10 per EXP15 (a minimum of four RAID 5 HDDs (3 plus a hotspare) per EXP15)
03K9311
Netfinity EXP 4.2 M Ultra2 SCSI Cable
8
RAID controller to EXP15s
Storage Subsystems
Netfinity SP Switch Components
01K7305
Netfinity SP PCI Host Adapter
8
1 per node for cluster interconnect
35291RY
Netfinity SP Switch (2U)
1
One 35291RY for up to 8 nodes, add SP Switch Option Card (P/N 01K7306) for
9 to 14 nodes.
1 per node for cluster interconnect
03K9221
Netfinity SP 5.0 M Cable
8
03K9309
Netfinity Advanced System Management Interconnect
Cable Kit
1
28L3644
Space Saver II Keyboard
1
Includes TrackPoint - Advanced TP features are not supported.
9513AG1
T55A Flat Panel Color Monitor (15.0") Viewable Image Size),
stealth black
1
Installs in keyboard tray 28L4707 with mounting kit 37L6857
9306900
Netfinity Rack Cabinet
4
Provides 42U of mounting space per rack
28L4707
Netfinity Rack Keyboard Tray (3U with monitor kit 37L6857
installed)
1
Allows keyboard 28L3644 to be stowed in a ready-to-use position
Required for installation of flat panel monitor in keyboard tray 28L4707
Other Non-rack
Rack / Related
37L6857
Flat Panel Monitor Rack Mount Kit
1
94G7445
Console Server Selector Switch (8-port)
1
Connects 8 nodes to monitor and keyboard
94G6669
Side Panel Kit
1
Provides side panels for both ends of the rack suite.
94G7446
Rack Attachment Kit
3
Provides hardware for attaching four racks together in a suite
94G6670
Blank Filler Panel Kit
4
Provides blank panels to fill the remaining rack space within the suite
94G6667
Power Cable - Type A14
28
Provides 14' power cables for UPS attachment to installed components
94G7447
12ft. Console Cable Set
8
Attaches each node to the console switch.
1. Cable, power, cooling and weight are dependent on component placement within the rack and rack suite. This parts list reflects one possible configuration of the listed components.
Prior to ordering, you should configure your specific environment using the Netfinity Rack Configurator. The Netfinity Rack Configurator is downloadable from URL
www.ibm.com/pc/us/products/server/download.html.
2. Pre-installation site planning information: 94G6676 contains eight L5-30P, 120V 30 amp circuitry.
Updated 01/01/00
For the latest product & technical information, refer to the Information Sources on pages 1 and 2.
103
IBM Netfinity NetBAY3/NetBAY3E Stackable
Enclosures
Installation Guidelines:
1) Locate power units with line cords in the bottom enclosure.
2) Install components starting from the bottom; start with the heaviest device.
3) If nothing is installed in the enclosure, attach the rear blank panel for stability.
Sample
Configuration
Netfinity 7000
M10
NetBAY3
36 in.
914 mm
Networking
EXP15
36 in.
914 mm
UPS
36 in.
914 mm
19 in.
483 mm
6 in.
152 mm
3.2 ft2
0.29 m2
36 in.
914 mm
26 in.
660 mm
19 in x 24 in.
483 mm x 610mm
Front
Service clearance
Supported Devices
NetBAY3 NetBAY3E
6 in.
20 in.
152 mm
508 mm
Operational clearance
(1.7 ft.X 3 ft.= 5 ft.2)
(508 mm x 914 mm = 0.46 m2)
(7.6 ft. X 8.2 ft.= 62.3ft2)
(2316 mm x 2499 mm = 5.79 m2)
Size (U) Weight(lb/kg) Max/Enclosure
36 in.
914 mm
Max/Stack
Servers
Netfinity 7000-M101
Netfinity 5500
Netfinity 5500-Mxx
Netfinity 8500R3
X
X
X
-
X
-
160/72.6
120/54.4
123.4/56.0
170/77.1
n/a
n/a
n/a
n/a
1
1
1
1
X
X
3
107/48.5
1
3
NetMEDIA 3551001
X
X
3
37/17
1
3
APC Smart-UPS 1400RMB
APC Smart-UPS 3000RMB
100-120V PDU
200-240V PDU
X
X
X
X
X
X
X
X
3
3
1
1
55/24.9
112/50.8
5/2.3
8/3.6
1
1
1
1
1
1
1
1
Expansion2
Netfinity EXP15
Tape Units2
Power2
Networking2
2210 Multiprotocol Router
X
X
1, 2
7/3.2, 20/9.1
3, 1
9, 3
8230 T-R Controlled Access Unit
X
X
2
15/6.8
1
3
8235 Dial-in Access to LANs
X
X
1
8/3.6
3
9
8237 Ethernet Hub
X
X
2
10/4.5
1
3
8238 Nways T-R Hub
X
X
2
11/5.0
1
3
8271 Ethernet Switch
X
X
2
16/7.3
1
3
8272 T-R Switch
X
X
2
16/7.3
1
3
8285 ATM Switch
X
X
3
70/31.8
1
3
1. Netfinity 7000-M10 systems are rack mountable and ship without a keyboard. In order to be utilized with a NetBAY3 or in a tower configuration, optional Rack-to-Tower
Conversion Kit (P/N 01K8005) must be installed.
2. NetBAY3 and NetBAY3E do not contain a top cover and therefore require a supported server as the top component in a stack
3. Netfinity 8500R systems are rack mountable and ship without a keyboard. In order to be utilized with a NetBAY3E or in a tower configuration, optional Rack-to-Tower Kit (P/N
28L4705) must be installed. .
104
IBM Netfinity NetBAY3/3E Stackable Enclosure
Monitor/
Keyboard1
Netfinity 5500,
5500 Mxx
Std. NetBAY32
Std. NetBAY32
NetBAY3
(P/N 10L6912)
Maximum of 3
Stackable
Enclosures
IBM NETFINITY NETBAY3
STACKABLE ENCLOSURE
Netfinity 5500,
5500 Mxx
NetBAY3
(P/N 10L6912)
Skid Pads
Casters
P/N 10L6913
Monitor/
Keyboard1
Monitor/
Keyboard1
Netfinity
8500R4
Netfinity
7000 M103
Netfinity 3
7000 M10
,
8500R4
NetBAY3
(P/N 10L6912
Maximum of 3
Stackable
Enclosures
NetBAY3
(P/N 10L6912)
NetBAY3
(P/N 10L6912)
NetBAY3E
(P/N 36L9701)
NetBAY3E
(P/N 36L9701)
NetBAY3E
(P/N 36L9701)
Standard
Casters3, 4
1. Rack models of Netfinity servers ship without a keyboard or mouse. Those supported for stacking on a NetBAY3 or NetBAY3E must have a rack-totower kit installed. See the specific system configurator under the section titled "Netfinity....Power, Monitor & Accessories".
2.Netfinity 5500 and 5500 Mxx tower models or models with Rack-to-Tower Kit (P/N 01K8021) include a single NetBAY3 with skid pads.
3. The rack-to-tower conversion kit for Netfinity 7000 M10 includes casters which can also be used with optional NetBAY3 (P/N 10L6912).
4. The rack-to-tower conversion kit for Netfinity 8500R includes casters which can also be used with optional NetBAY3E (P/N 36L9701).
Updated 01/01/00
For the latest product & technical information, refer to the Information Sources on pages 1 and 2.
105
IBM Netfinity Rack Cabinet and Options
Note: For a robust rack configurator application access URL http://www.ibm.com/pc/us/products/server/download.html.
Direct Rack Mount1: Units Supported
9306-900
1st Console
Switch, if no
monitor
compartment
IBM Servers
42U
Vertical Rack Mount Area
22U
38
37
36
35
NetBAY22
9306-200
34
33
32
31
30
29
28
27
A 26
25
1U5
Rack Models
5U
Netfinity 5500, 5500 Mxx
Rack Models
8U
Netfinity 5600
Rack Models
5U
E
Special Side Wall
Compartments
20
19
18
17
16
15
Netfinity 7000 M10
All Models
11U
Netfinity 8500R
All Models
8U4
IBM Storage Expansion Units
Mounting Location
for Display and
Keyboard
B
24
23
22
21
2nd
All Models
Netfinity 5000
Netfinity 4000R
42
41
40
39
Netfinity EXP15
3520-2Rx
Netfinity EXP200
35301RU
3U
7133 Serial Disk System2, 3
7133-020
4U
IBM Fibre Solutions
22
21
20
19
18
17
RAID Controller Unit
35261RU
4U
Fibre Channel Hub
35231RU
1U
IBM Tape Units
16
15
C 14
13
12
11
10
PDU 9
8
7
6
D
1st PDU
1st Console
Switch, if no
monitor
compartment,
or 2nd PDU
5
4
3
2
1
A 14
13
12
11
10
9
8
7
6
D
1st PDU
3551001
3U
Magstar MP 3570
3570B21/B22
6U
Magstar MP 3570
3570C21/C22
6U
NetMEDIA
IBM Networking Products
Dial-in Access to LANS
5
4
3
2
8235-03x
1
Console Switch
• Mounts to rear flanges
• Shares 3U space with display, keyboard and tray
Keyboard Tray Components
• 28L4707 Netfinity Rack Keyboard Tray
• 37L6857 Netfinity Flat Panel Monitor Rack Mount Kit
• 28L3644 Space Saver Keyboard
• 9513AG1 T55A Flat Panel Color Monitor
Keyboard Tray
Mounting Flanges
Slide-Out and Flip-Up
106
1U
1. Mounting hardware provided with product
2. Requires Rail Kit (FC 3093). 208V Power cord included, optional
110V power cord (FC 9886/1.8M or FC 9800/2.8M) can be ordered.
If the Black Cover Kit (FC 3020) is ordered, no white cover is
shipped with system. Other specify codes may be required.
3. The 7133 Serial Disk System is not a IBM Personal Systems
Group product. For additional configuration support, product
information and ordering of these IBM Storage offerings, visit the
IBM storage Website http://www.ibm.com/storage or contact your
IBM representative.
4. Netfinity 8500R requires installation of extension kit 36L9703 or
36L9702 when installed in a 9306-900 or 9306-200 respectively
for proper rear door closure clearance.
5. To provide adequate cooling, rack front door must be removed.
Keyboard/Pointer/Monitor & Switch ... all in 3U
Front
3U
Optional Accessories
Part
Number
Mounting Support
Rack Space
Units Supported
Fixed Shelf:
width x depth= (439 mm x 663mm) 17.3 in. x
2 to xx U
26.1 in
max. weight= (45 kg)100lbs.
IBM Networking Products
8222-008, 016
8225-003
85H6735
Network Products Mounting Kit
IBM Networking Products
Ethernet Switch
8271-108, 216
Ethernet Hub
8237-00x
Token-Ring Switch
8272-108
Token-Ring Controlled Access Unit8230-04A, 04P
Nways LAN Switch
8270-800
Nways Token-Ring Hub
8238-xx1
ATM Switch
8285-00B, 00E
Multi-Protocol Router
2210-12x
Multi-Protocol Router
2210-x4x
36L9702
Netfinity NetBAY22 Rack Extension Kit
installs on the rear of a 93062001.
-
Netfinity NetBAY22
9306200
36L9703
Netfinity Rack Extension Kit installs on the
rear of a 93069001.
-
Netfinity Rack
9306900
94G7442
Part
Number
Description
1 to 5 U
Nways Enet Wkgp Hub
Ethernet Hub
Console Support
2U
2U
2U
2U
2U
2U
5U
2U
3U
1U
2U
Devices Supported
Devices
Height
Part Number
Monitors
94G7444
Monitor compartment
One monitor and one console
G54
9U
-
G74
10U
-
Keyboards/Mouses2
Netfinity Rack Keyboard Tray
Space Saver II Keyboard 3, 4
1U
28L3644
TrackPoint IV 104-Key3
1U
01K1260
Tower Model Keyboards5
1 to 2U
T55A flat panel monitor 6
-
Flat Panel Monitor Mount Kit7
Supports installation of a flat
panel monitor into tray 28L4707
37L6857
Flat Panel Monitor Rack Mount Kit
94G7445
Console Server Selector Switch (8-port, Tier Mounts behind monitor compartment or
in rack side
up to 64)
28L0542
Netfinity Console Server Selector Switch (4- and flat panel kit 37L6857 it can also be
installed behind the keyboard tray.
port)
94G7447
Console Cable Set- (3.66 m) 12 ft.
When used with keyboard tray 28L4707
Attaches server to console switch
-
Monitors
3U
9513AG1
37L6857
Monitors
T55A Flat Panel Monitor
-
9513AG1
Console Cable Set - 12ft. (366 m)
-
94G7447
Console Server Selector Switch (8-port)
-
94G7445
Netfinity Console Server Selector Switch (4-port)
-
28L0542
1.Expands current racks for better cable management or to accomodate systems requiring greater installation depth.
2. Check system sections for support of desired keyboards, mouse and monitors.
3. Advanced TrackPoint IV features are not supported by Netfinity servers or rack console switches.
4. Space saver keyboards may be stowed in a ready-to-use position within tray 28L4707.
5. Tower models of Netfinity servers includes keyboards, which are supported by both keyboard trays and console switches. These are not space saver keyboards.
6. Installation in a Netfinity Rack Keyboard Tray (P/N 28L4707) requires Netfinity Flat Panel Monitor Rack Mount Kit (P/N 37L6857). A space saver keyboard may coexist within the same 28L4707
keyboard tray.
7. When installed in Netfinity Rack Keyboard Tray (P/N 28L4707) a flat panel monitor and space saver keyboard may coexist in th e tray. Hardware is included for mounting a console selector switch
to the rack directly to the rear of the tray thus sharing the same 3U space. See the Keyboard/Pointer/Monitor & Switch diagram above.
Updated 01/01/00
For the latest product & technical information, refer to the Information Sources on pages 1 and 2.
107
IBM NETFINITY RACK CABINET
28L4707
One flat panel display and one
space saver keyboard, and one
keyboard mouse
Part
Number
Power Support
Rack Space
Comments
100-120V 12a Power Distribution Unit
--
8 NEMA 5-15R outlets
Mounts in rack side wall D,C
94G7450
200-240V 16a Power Distribution Unit
--
10 IEC 320-C13 outlets
Mounts in rack side wall D,C
94G6674
94G6675
1400VA UPS
94G6676
94G6677
3000VA UPS
94G6666
94G6667
94G7448
Part
Number
94G6670
120V
220-240V
120V
120-240V
US/C/LA
3U
EMEA/AP
6 NEMA 5-15R outlets
4 IEC 320-C13 outlets
US/C/LA
3U
EMEA/AP
8 NEMA 5-15R outlets
8 IEC 320-C13 and 1 C19
Power Cables
Type Connectors
A14 IEC 320-C13 to NEMA 5-15P
C12 IEC 320-C13 to IEC 320-C14
Miscellaneous
Blank Filler Panel Kit
1U panel (qty. = 2)
3U panel (qty. =1)
5U panel (qty. = 1)
Length
(4.27 m) 14 ft.
(3.66 m) 12 ft.
-
Rack Space
1U + 1U
3U
5U
Comments
Use as required to fill empty space in the vertical rack mount area.
Note: You can select up to two power units per rack. Select the optional Power Cables when the standard cable is not long enough or has incompatible
power plug.
9306-900 Single Cabinet or Multi-Rack Suite Options
Side Panel Kit (94G6669)1
Single Stand-alone
IBM Netfinity Rack Cabinet
2 Locking
Side Panels
Rack Attachment Kit (94G7446)1
Bolts, Brackets,
and Trim Pieces
front and side
stabilizers required
Multi-Rack Suites -- 2 to 8 racks
1. Supported on 9306-900 only.
108
side stabilizers not required
Netfinity Rack - Cabinet and Options Dimensions
9306-900 and NetBAY22 (9306-200)
26 in.
660 mm
42 in.
1067 mm
36 in.
914 mm
Dimensions
for NetBAY22
(9306-200)
30 in.
762 mm
36 in.
914 mm
23.6 in.
600 mm
Front View
12 in.
305 mm
25.5 in.
648 mm
Dimensions
for NetBAY22
(9306-200)
42U
Top View
22U
5.6 ft.2
.52m2
90 in.
2286 mm
81.5 in. 46.25 in.
2070 mm 1175 mm
34.5 in.
876 mm
(23.5 in. x 34.in.)
(597mm x 864mm)
Side Stabilizers
not required on
a NetBAY22
(9306-200)
30 in.
762 mm
60 in.
1524 mm
Side Stabilizers
not required on
a NetBAY22
(9306-200)
Front
Operational Clearance
(3.5 ft. x 7.5 ft. = 26.25 ft.2)
(1067 mm x 2286 mm = 2.44 m2)
9306-900
EIA 310-D standard 19-inch,
type A cabinet
1U = (44.45 mm)1.75 inches
9306-200
Weight Moveable Stationary
(lb/kg)
Moveable or
Stationary
Empty rack
276/125
276/125
182/83
Max load
824/374
1424/646
746/338
Total
1100/499
1700/771
928/421
Internal
Dimensions
Top View
31.8 in.
(807.7 mm)
(surface to
surface)
to lock = 1.4 in.
(35.6 mm)
to door = 2.3 in.
(58.4 mm)
IBM NETFINITY RACK CABINET
Service Clearance
(8 ft. x 10.4 ft. = 83.2 ft.2)
(2438 mm x 3170 mm = 7.73 m2)
Mounting flange dimensions and
universal hole spacing defined
by EIA 310 for 19-inch racks
28.125 in.
(714.4 mm)
(inside flange to
inside flange)
to frame = 2.2 in.
(55.9 mm)
to glass = 3.0 in.
(76.2 mm)
Front
Switch Arrangements
Tiering
Single Switch
Console
Console
Primary Switch
console
cable set
Secondary
Switch
Switch
console
cable set
Secondary
Switch
Up to 4 or 8 Servers
(depending on switch type)
Up to 64 Servers
(depending on switch type)
Updated 01/01/00
For the latest product & technical information, refer to the Information Sources on pages 1 and 2.
109
01K1282 12/24 GB DDS/3 4-mm Internal Tape Drive
8
00N7991 20/40 GB DDS/4 4-mm Internal Tape Drive
16 Ultra2
LVD
01K1319 10/20 GB NS Internal SCSI Tape Drive
01K1325 20/40 GB 8-mm Internal SCSI Tape Drive
8
16
5.25”HH
Te
rm
in
at
ion
68
In
/50
cl.
-p
in
Co
In
nv
te
er
rn
te
al
rI
Ca
nc
ble
l.
s
Da
In ta/C
clu le
de an
ing
d
Ca
Ex
r tr
t.
id
Ta
ge
pe
s
En
clo
su
re
s1
pr 2
.
/co
m
pr 2
.
Na
tiv
e
se
c-
MB
/
GB
-N
at
ive
/C
om
h it
e
3.5”HH or
5.25”HH
3.5”HH or
5.25”HH
3.5”SL or
5.25”HH
Ma
x
Be
ze
l-
(B
)l a
Fa
ct
or
ck
,(
W)
(b
it)
Fo
r
Description
SC
Pa
rt
SI
m
In
te
r
fa
ce
SCSI Interface
LEGEND
HH: Half High - approx. height of 1.6”
SL: Slim Line - approx. height of 1”
Nu
m
be
r
Appendix A: Tape Drive Attributes
B/W
12/24
1.1/2.2
Y3
Y
-
1/1
B
20/40
2.75/5.5
Y3
-
-
1/1
B/W
10/20
1/2
Y3
Y
-
1/0
3/6
N4
-
-
1/1
B
20/40
16-bit,
4 drop
16-bit,
4 drop
01K1320 20/40 GB DLT Internal SCSI Tape Drive
8
5.25”FH
B
20/40
1.5/3
Y6
Y
04K0149 35/70 GB DLT Internal SCSI Tape Drive
16
5.25”FH
B
35/70
5/10
N4
-
-
1/0
1/0
1/0
3510020
3510020,
3551001
3510020,
3551001
35100205,
3551001
3503B0X,
3551001
3503B0X5,
3551001
3503B0X5,
3551001
16 LVD
5.25” FH
B
40/80
6/10
N4
32G3918 SCSI-2 16-bit Active Terminator
16
Ext.
-
-
-
Y
N
-
-
94G7587 PC Server SCSI Terminator Kit
32G3925 SCSI 68-pin to 50-pin Converter
8/16
8/16
Int.
Int.
-
-
-
Y
N
N
Y
-
16
Int.
-
-
-
Y
N
16-bit,
2 drop
3510020,
3503B0X
3551001
-
-
8/16
Desktop
B
-
-
N
N
-
-
16
Rack
B
-
-
Y
N
-
-
16
16
Desktop
B
-
-
N
N
N
N
8-bit or
16-bit
16-bit,
4 drop
N
16-bit
-
3551001
-
16
Desktop
Desktop or
Rack
Desktop
Desktop or
Rack
B
280/560
5/10
Y
-
-
1/1
-
B
490/980
5/10
Y
-
-
1/1
-
B
320/640
6/12
Y
-
-
1/1
-
B
680/1120
6/12
Y
-
-
1/1
-
100/300
2.2/6.6 or
7.0/15.0
Y
-
-
1/1
-
00N7990 40/80 GB DLT Internal SCSI Tape Drive
Associated Options
36L9636 Netfinity Two-Drop Internal SCSI Cable7
External Tape Enclosures
3510020 External Half High SCSI Storage Enclosure8
3551001 NetMEDIA Storage Expansion Unit EL9
10L7113 NetMEDIA Systems Management
3503B0X DLT External SCSI Enclosure11
External Tape Libraries12
3502108 DLT Tape Autoloader
Adapter10
3502x14 DLT Tape Library
16
3503108 DLT8000 Tape Autoloader
16 LVD
3503x14 DLT8000 Tape Library
16 LVD
3570xxx Magstar MP 3570 Tape Subsystem (models B2x and C2x
Diff.
Rack
B
1. To determine cable requirements, note the tape drive’s SCSI interface, the appropriate SCSI controller from the system configurator section and the desired enclosure then refer to
Appendix D: Cables-Storage Units-Controllers.
2. Data compression typically provides a 2X improvement in capacity and transfer rate, but since data compression is affected by many factors, actual improvements may be more or
less than 2X.
3. Tape drive is capable of self termination.
4. If installed as the last or only device on a SCSI cable, termination is required. Check system unit SCSI cabling to assure termination is included. Where internal termination is not
included, PC Server SCSI Terminator Kit (P/N 94G7587) should be used.
5. Requires SCSI-2 16-bit Active Terminator (P/N 32G3918).
6. A 16-bit terminator is included for attachment to an internal cable.
7. Netfinity Two-Drop Internal SCSI Cable (P/N 36L9636) is a wide two-drop terminated cable and is required for attachment of internal tape drives to the onboard SCSI controller of
a Netfinity 1000, 3000, 3500 M10, or 5000 when the hard disk drives are attached to a RAID Controller.
8. Provides a black desktop 5.25” half-high (HH) tape enclosure. Connector is configurable as 50-pin Centronix or 68-pin high density. Requires either tape drive self termination or
SCSI-2 16-bit Active Termination (P/N 32G3918).
9. Provides a black 3U, 19” rack or NetBAY3 mountable tape enclosure. Provides two full high (FH) or four half-high (HH) extended length 5.25” bays. External connector is 0.8-mm
VHDCI. Includes two power supplies and two power cords.
10. Installs in a 3551001. Provides repeater function and LVDS interface allowing longer cable lengths and auto-termination when the 3551001 is powered off.
11. Provides a black desktop DLT tape enclosure. External connector is 68-pin high density. Requires termination by the tape drive or by installation of a SCSI-2 16-bit Active
Termination (P/N 32G3918).
12. Tape library attributes and prerequisites are located in Appendix B: Tape Library Attributes.
Note: SCSI support for tape drives is provided by system unit onboard (standard) controller (no-RAID function) or PCI Fast Wide Ultra SCSI Adapter P/N 02K3454.
110
SCSI Interface
Fa
ct
or
ce
Fo
rm
Description
SI
In
te
r fa
F: Female - External
M: Male - External
68: 16-bit, 68 pin High Density Connector
Diff: Differential SCSI
SC
Pa
rt
Nu
m
be
r
LEGEND
Be
ze
l(B
)l a
Te
rm
ck
in
at
or
In
clu
de
d
Ex
te
rn
al
Ca
ble
sI
nc
l.
(m
SC
)
SI
Co
nt
Da
ro
lle
ta
rs
Ca
In
r tr
cl
idg
Cl
.
ea
es
ni
st
ng
d
Ca
./m
C
ar
r tr
ax
tri
id
dg
ge
Qt
es
y.
Ma
of
s
gs
td
dr
.
st
ive
d.
s/m
ax
s
Ma
td
./m
x
GB
ax
-N
at
ive
/C
om
MB
pr
/se
es
cse
d
Na
tiv
e/c
om
pr 1
.
Appendix B: Tape Library Attributes
3502108 DLT Tape Autoloader
M68
Desktop
B
Y
3502314
3502R14
33L4979
94G7442
3503108
3503314
3503R14
09N4035
3570B21
.3570B22
3570C21
3570C22
08L6517
08L6516
08L6480
M68
M68
M68
LVD
LVD
LVD
LVD
Diff
Diff
Diff
Diff
Diff
Diff
Diff
Desktop
4U Rack
Desktop
Desktop
4U Rack
6U Rack
6U Rack
6U Rack
6U Rack
-
B
B
B
B
B
B
B
B
B
-
Y
Y
N
Y
Y
Y
N
Y
Y
Y
Y
Y
-
DLT Tape Library - Tower
DLT Tape Library - Rack2
DLT Library Drive Upgrade3
Fixed Shelf
DLT8000 Tape Autoloader11
DLT8000 Tower Tape Library11
DLT8000 Rack Tape Library11
DLT8000 Drive Upgrade4, 11
Magstar MP 3570 Tape Subsystem5
Magstar MP 3570 Tape Subsystem5
Magstar MP 3570 Tape Subsystem5
Magstar MP 3570 Tape Subsystem5
3570 Adapter Card Kit7
Second “B” Drive for B218
Second “C” Drive for C218
M68-M68 3,
M0.8mm - F68
Converter
M68-M68 3
M68-M68 3
Jumper
M68-M68 3
M68-M68 3
M68-M68 3
Jumper
4.5
4.5
4.5
4.5
4.5
-
Y
1/8
1
1/1
1/1
280/560
5/10
Y
Y
N
Y
Y
Y
N
Y
Y
Y
Y
Y
N
N
1/14
1/14
1/8
1/14
1/14
1/20
1/20
1/20
1/20
-
1
1
1
1
1
1
1
1
1
-
2/2
2/2
1/1
2/2
2/2
2/2
2/2
2/2
2/2
-
1/3
1/3
1/1
1/3
1/3
1/2
2/26
1/2
2/26
-
490/980
490/980
320/640
680/1120
680/1120
100/300
100/300
100/300
100/300
-
5/10
5/10
5/10
6/12
6/12
6/12
6/12
2.2/6.6
2.2/6.6
7.0/15.0
7.0/15.0
2.2/6.6
7.0/15.0
-
Magstar MP Media9
Magstar MP Fast Access Linear Tape Cartridge,
05H2462 B-format10
-
-
-
-
-
-
-
-
-
-
-
05H2463 Magstar MP Cleaning Cartridge
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Magstar MP Fast Access Linear Tape Cartridge,
08L6187 C-format
TAPE ATTRIBUTES
1. Transfer rates are for single SCSI channel configurations. Tape libraries utilizing split library or dual host configurations may obtain higher rates. Data compression typically provides a 2X
improvement in capacity and transfer rate, but since data compression is affected by many factors, actual improvements may be more or less than 2X.
2. Requires Fixed Shelf (P/N 94G7442) for installation in an IBM rack or NetBAY22.
3. Upgrade 33L4979 is an additional drive for 3502x14 DLT Tape Libraries. Up to two drive upgrades may be installed for a maximum of three drives per 3502x14.
4. Upgrade 33L4035 is an additional drive for 3503x14 DLT Tape Libraries. Up to two drive upgrades may be installed for a maximum of three drives per 3503x14.
5. Includes rack mounting hardware and two power cords (120 V and 250 V). Models B22 and C22 include an additional 2 power cords.
6. The two tape drives are daisy-chained on the same SCSI bus with an included 0.5 meter SCSI cable. Dual Host and Split Library configurations require 3570 Adapter Card Kit
(P/N 08L6517).
7. Required for Dual Host or Split Library configurations with 3570B2x or 3570C2x containing two drives.
8. Required for either dual host or split library operation. Should be installed by qualified service personnel.
9. Magstar MP Media can be ordered by calling 888-IBM-MEDIA or 888-426-6334 in the US, Canada, or Puerto Rico.
10. B-format tape cartridges can be used in either Magstar MP 3570 Model B or C tape drives.
11. Planned availability of November 1999.
Updated 01/01/00
For the latest product & technical information, refer to the Information Sources on pages 1 and 2.
111
112
Appendix C: UPS Runtime Estimate (minutes)
Servers
Netfinity 10002, 5
Netfinity 30002
Netfinity 3500 M10
Netfinity 4000R
Netfinity 50002
Netfinity 55002
Netfinity 5500 M102
Netfinity 5500 M202
Netfinity 56002
Netfinity 7000 M102
Netfinity 8500R2
Tower
Rack Mount
International SU-700iNET SU-1000iNet SU-1400iNET SU-2200iNET SU-1400RMiB SU-3000RMiB
Part Number 94G4073
94G4074
94G4075
94G4076
94G6675
94G6677
United States SU-700NET SU-1000NET SU-1400NET
Not
SU-1400RMB SU-3000RMB
Part Number 94G3134
94G3135
94G3136
Available
94G6674
94G6676
Watts Load
minimum/
minimum/
minimum/
minimum/
minimum/
minimum/
Max./Typ.1
typical4
typical4
typical4
typical4
typical4
typical4
# Pwr. Cords
Std/Max
VA Load
Max./Typ.1
1/1
1/1
1/1
1/1
1/2
1/2
1/2
1/2
2/3
1/2
3/3
225/160
225/160
300/210
210/150
475/330
540/375
540/375
640/450
350/245
745/525
1450/1015
225/160
225/160
300/210
150/105
475/330
540/375
540/375
640/450
350/245
745/525
1450/1015
22/32
22/32
12/20
-
36/51
36/51
22/36
12/19
18/28
-
57/80
57/80
34/57
20/30
16/26
16/26
12/20
29/43
12/17
-
114/156
114/156
85/21
47/76
38/63
38/63
31/54
73/104
26/40
-
63/91
15/23
12/21
12/21
9/15
22/34
8/12
-
130/165
42/62
35/55
35/55
29/45
59/84
26/35
9/16
2/2
400/280
400/280
-
-
-
-
18/27
57/84
1/2
400/280
400/280
-
-
-
-
18/27
57/84
2/2
160/105
160/105
-
-
-
-
60/91
140/183
1/1
1/1
1/1
1/1
1/1
1/1
2/2
2/2
-
135/100
135/100
135/100
135/100
110/75
200/140
185/130
115/80
42/61
42/61
42/61
42/61
55/85
22/39
25/44
54/80
62/80
62/80
62/80
62/80
75/100
39/59
42/64
74/95
96/127
96/127
96/127
96/127
118/163
63/92
69/98
116/155
179/221
179/221
179/221
179/221
209/268
129/173
138/182
206/250
72/99
72/99
72/99
72/99
91/131
45/68
50/74
90/125
142/173
142/173
142/173
142/173
165/207
103/137
111/145
162/197
-
-
-
1
black3
-
1
black3
-
1
black3
-
1
white
-
1
black
3U
3
black
3U
-
-
-
4
C14
4
C14
4
C20
8, 1
C20
4
C14
8, 1
C20
-
-
-
4
6 ft., 5-15P
6
6 ft., 5-15P
6
6 ft., 5-15P
-
6
6 ft., L5-15P
8
6 ft., L5-30P
Other Devices
Netfinity EXP15 (3520)2
Netfinity EXP200 Storage Expansion Unit
(35301RU)2
Netfinity Fibre Channel RAID Controller Unit
(3526)2
DLT Tape Autoloader (3502-108)
DLT Tape Library (3502-R14/314)
DLT 8000 Tape Autoloader (3503-108)
DLT 8000 Tape Library (3503-R14/314)
Magstar MP 3570 Tape Subsystem (B2x)
Magstar MP 3570 Tape Subsystem (B2x)
NetMEDIA Storage Expansion Unit EL (3551)
Netfinity SP Switch (35291RY)
UPS Attributes
Communication Links to Servers
Color
EIA Height
International Models
Receptacles (IEC 320-C13, C19
Live Cord Receptacle (IEC 320-)
US Models
Receptacles (NEMA 5-15R)
Line Cord Length, Plug
1. This table represents general guidelines for selecting the appropriate UPS based on minimum and typical runtime estimates. A ‘maximum configuration’ load will result in ‘minimum’ UPS runntime. ‘Typical’ loads are based on a production system
running at approximately 70% of maximum capacity. The ‘typical’ loads represent a more likely configuration and, therefore, a more likely estimate of runtime. Customer environments are unique and are unlikely to be precisely represented by any of
the specific entries in the table.
2. Power-Factor Corrected (PFC) power supply. Runtime estimates have been adjusted accordingly.
3. Early versions were white. US versions currently shipping in cartons clearly marked as “black”. International version will be black by the end of 1Q99.
4. Data provided by APC.
5. Netfinity 1000 is not available in the Americas.
6. Netfinity 4000R is only available in the United States.
Note: For runtime estimates of multiple components attached to a single UPS, add the number of Watts for all selected components. Use the total Wattage and Total Configuration Runtime Estimator to determine which UPS provides an acceptable
duration of estimated runtime.
Total Configuration Runtime Estimator (Time in minutes)1
Tower
Rack Mount
Total
Configuration
Load (Watts)
SU-700NET
94G3134
SU-1000NET SU-1400NET Not Available SU-1400RMB
94G3135
94G3136
94G6674
UPS RUNTIME
SU-700iNET SU-1000iNET SU-1400iNET SU-2200iNET SU-1400RMiB SU-3000RMiB
94G4073
94G4074
94G4075
94G4076
94G6675
94G6677
SU-3000RMB
94G6676
200
22
38
62
130
45
104
250
17
28
43
104
34
84
300
12
22
34
85
25
70
350
9
18
29
71
22
58
400
7
14
23
65
18
52
450
5
12
20
52
15
45
500
-
11
18
43
13
38
550
-
9
16
38
11
35
600
-
8
13
34
10
31
650
-
7
12
31
9
29
26
700
-
6
11
28
8
750
-
-
10
25
8
24
800
-
-
9
23
7
22
850
-
-
8
21
7
20
900
-
-
7
19
6
18
950
-
-
6
18
5
17
1000
-
-
-
17
-
16
15
1050
-
-
-
16
-
1100
-
-
-
15
-
14
1150
-
-
-
14
-
13
1200
-
-
-
13
-
12
1250
-
-
-
12
-
11
1300
-
-
-
11
-
10
1350
-
-
-
10
-
9
1400
-
-
-
10
-
9
1450
-
-
-
9
-
8
1500
-
-
-
9
-
8
1. Data provided by APC.
Steps:
1. Identify the devices contained in the configuration.
2. Sum the load (watts) of all devices in the configuration. Use either Maximum Load for minimum runtime, or Typical Load for typical runtime.
3. Find the Total Configuration Load in the table above.
4. Select the most appropriate UPS model to achieve the desired runtime.
NOTE: If the Total Configuration Load is greater than the entries above, split the load across two or more UPS units.
Updated 01/01/00
For the latest product & technical information, refer to the Information Sources on pages 1 and 2.
113
114
Appendix D: Cables - Storage Units - Controllers
Instructions: Identify Desired Controller Row and Storage Unit Column. The intersection of row and
F:
M:
I:
68:
50:
0.8:
16:
8:
column contains the cable group letter which supports the connection. Go to the cable group under the
corresponding storage unit for specific support. Read all Notes for row, column, and any cable group
footnotes.
Female - External
Male - External
Internal
16-bit, 68-pin High Density connector
8-bit, 50-pin Centronix Connector
16-bit, 68-pin Very High Density Connection
Interface (VHDCI) 0.8 mm connector
16-bit, 68-pin connector
8-bit, 50-pin connector
Description
Part
Number
Storage Unit 35202RU 35301RU 3510020 3503B0X 3551001 Adapter
10L7113
Max.MB/sec.6
LVDS
Connector Type
40
X
F0.8
80
X
F0.8
F68 or F50
F68
F0.8
F0.8
Max./
Connector
Channel LVDS
Type/
Note #
(MB/sec)6
Max
8, 13
8, 16
10, 11
11, 12
8, 11
8, 11, 15
RAID Storage Controllers
Netfinity Fibre Channel RAID Controller Unit
35261RU
80
X
F0.8/6
9
A
-
-
-
-
-
Netfinity ServeRAID-3HB Ultra2 SCSI Adapter
37L6086
80
X
F0.8/3
-
A
A
-
-
-
-
Netfinity ServeRAID-3H Ultra2 SCSI Adapter
01K7207
80
X
F0.8/3
-
A
A
-
-
-
-
Netfinity ServeRAID-3L Ultra2 SCSI Adapter
01K7364
80
X
F0.8/1
-
A
A
-
-
-
-
Netfinity 5500, 5500 M10 - ServeRAID II
Onboard
40
-
F0.8/12
2
A4, 5
A4, 5
B, G14
B14
A14
A14
Netfinity 5500 M20 - ServeRAID II
Onboard
40
-
F 0.8/1
-
A4, 5
A4, 5
B, G14
B14
A14
A14
Advanced SerialRAID/X Adapter
09L2123
-
-
SSA
-
-
-
-
-
-
-
Ultra SCSI Controllers
PCI Fast/Wide Ultra SCSI Adapter
02K3454
40
-
F68/1
-
B5
B5
C, G
C
B
B
Netfinity 1000 - Wide Ultra SCSI18
Onboard
40
-
F68/1
-
-
-
C, G
C
-
-
Netfinity 3000 - Wide Ultra SCSI
Onboard
40
-
F68/1
-
-
-
C, G
C
-
-
Netfinity 3500 M10- Wide Ultra SCSI
Onboard
40
-
F68/1
-
-
-
C, G
C
B
B
Netfinty 4000R19
Onboard
40
-
F68/1
-
-
-
-
-
B
-
Netfinity 5000 - Wide Ultra SCSI
Onboard
40
-
F68/1
-
-
-
C, G
C
B
B
Netfinity 5600- Wide Ultra2 SCSI
Onboard
80
X
F0.8/1
-
-
-
B, G
B
A
A
Netfinity 7000 M10 - Wide Ultra SCSI
Onboard
40
-
F0.8/1
-
-
-
B, G
B
A
A
Netfinity 8500R- Wide Ultra2 SCSI
Onboard
80
X
F0.8/1
-
-
-
B, G
B
A
A
Related Options
0.8mm to 68-pin SCSI Adapter
01K8017
-
-
M0.8-F68
1
-
-
G
-
-
-
Netfinity SCSI Controller Cable
03K9313
-
-
I16-F0.8
2
A4, 5
A4, 5
B, G
B
A
A
Netfinity 2M Ultra2 SCSI Cable
03K9310
-
X
M0.8-M0.8
3
X
X17
-
-
X
X
Netfinity 4.2M Ultra2 SCSI Cable
03K9311
-
X
M0.8-M0.8
3
X
X
-
-
X
X
Netfinity 20 M Ultra2 SCSI Cable
37L7101
-
X
M0.8-M0.8
4
X4
X4
-
-
-
-
Cable Group A (M0.8-M0.8)
Cable Group B (M68-M0.8)
1M External .8mm SCSI Cable
76H3589
-
-
M68-M0.8
-
X
X
X
X
X
X
2M External .8mm SCSI Cable
01K8027
-
-
M68-M0.8
-
X
X
X
X
X
X
4.3M External .8mm SCSI Cable
01K8029
-
-
M68-M0.8
5
X
X
-
-
X
X
70G9857
-
-
M68-M68
-
-
-
X
X
-
-
Cable Group C (M68-M68)
PC Server F/W to F/W External SCSI Cable-1m
Cable Group D (Short Wave Fibre)
Netfinity Fibre Channel 5 M Cable
03K9306
-
n/a
S/W Fibre
-
-
-
-
-
-
-
Netfinity Fibre Channel 25 M Cable
03K9305
-
n/a
S/W Fibre
-
-
-
-
-
-
-
Customer supplied cables <500M (0.31 miles)
**********
-
n/a
S/W Fibre
-
-
-
-
-
-
-
**********
-
n/a
L/W Fibre
-
-
-
-
-
-
-
Cable Group E (Long Wave Fibre)
Customer supplied cables < 10 KM (6.2 miles)
Cable Group F (SSA)
Updated 01/01/00
Instructions: Identify Desired Controller Row and Storage Unit Column. The intersection of row and
F:
M:
I:
68:
50:
0.8:
16:
8:
column contains the cable group letter which supports the connection. Go to the cable group under the
corresponding storage unit for specific support. Read all Notes for row, column, and any cable group
footnotes.
Female - External
Male - External
Internal
16-bit, 68-pin High Density connector
8-bit, 50-pin Centronix Connector
16-bit, 68-pin Very High Density Connection
Interface (VHDCI) 0.8 mm connector
16-bit, 68-pin connector
8-bit, 50-pin connector
Description
Part
Number
Storage Unit 35202RU 35301RU 3510020 3503B0X 3551001 Adapter
10L7113
Max.MB/sec.6
LVDS
Connector Type
40
X
F0.8
80
X
F0.8
F68 or F50
F68
F0.8
F0.8
Max./
Connector
Channel LVDS
Type/
Note #
6
(MB/sec)
Max
8, 13
8, 16
10, 11
11, 12
8, 11
8, 11, 15
Cable Group G (Other)
PC Server F/W to Fast External SCSI Cable-1M
70G9858
-
-
M68-M50
-
-
-
X10
-
-
-
SCSI-2 16-bit Active Terminator
32G3918
-
-
M68
-
-
-
X
X
-
-
Cable Group H
Netfinity SP 2.3 M Cable
03K9220
-
n/a
-
-
-
-
-
-
-
-
Netfinity SP 5 M Cable
03K9221
-
n/a
-
-
-
-
-
-
-
-
Netfinity SP 10 M Cable
03K9222
-
n/a
-
-
-
-
-
-
-
-
GBIC
For the latest product & technical information, refer to the Information Sources on pages 1 and 2.
Netfinity Fibre Channel Short-Wave GBIC
03K9308
-
n/a
S/W Fibre
7
-
-
-
-
-
-
Netfinity Fibre Channel Long-Wave GBIC
03K9307
-
n/a
L/W Fibre
-
-
-
-
-
-
-
1. Converts a F0.8mm into a F68-pin connector for attachment of an external M68 cable.
2. Netfinity 5500 and 5500 M10 require IBM Netfinity SCSI Controller Cable (P/N 03K9313) to route the internal onboard SCSI RAID connector to an external F0.8 mm connector.
3. Supports attachment to Ultra2 or single-ended SCSI controllers with operational speeds of up to Ultra2. Controller, storage unit, cable length or storage device limitations may
apply (see Max. MB/sec row and column above).
4. Cable lengths exceeding 4.3 meters are NOT supported for attachment to non-Ultra2 controllers.
5. Installations with cable lengths greater than 2 meters are limited to SCSI Fast/Wide speeds of 20 MBps .
6. Maximum supported speeds may be limited by installation of lower speed devices, controllers or cable lengths greater than 2 meters.
7. Four short wave GBICs are included with Netfinity Fibre Channel Hub (P/N 35231RU).
8. Rack installation cable management requires devices to have a minimum cable length of 2 meters. Cable length requirements will vary based on placement within a single or
multiple rack suite.
9. Connection to either Netfinity Fibre Channel Hub (P/N 35231RU) or Netfinity Fibre Channel PCI Adapter (P/N 01K7297) requires short wave fibre cables from Cable Group D.
10. Cable groups B and C are for 16-bit tape drive installation while cable group G’s P/N 70G9858 applies to 8-bit drives. External Storage Unit 3510020 comes equipped with both
an F68 connector set for 16-bit tape drives and an F50 connector set for 8-bit drives. Attachment of cable P/N 70G9858 (Cable Group G) to a F0.8mm controller connector requires
IBM .8mm to 68-pin SCSI Adapter (P/N 01K8017).
11. Daisy chaining tape enclosures is not supported. Speeds are limited by cable lengths and installed devices.
12. Requires SCSI-2 16-bit Active Terminator (P/N 32G3918).
13. Attachment to wide ultra SCSI controllers limits operational speeds to Ultra SCSI (40 MBps) for cables up to 2 meters in length and Fast/Wide SCSI (20 MBps) for cable lengths
between 2 meters and 4.3 meters. Ultra2 SCSI controllers and cables allow cable lengths of up to 20 meters at up to 40 MBps.
14. RAID support for tape drives is limited to Non-RAID functions and utilization of a dedicated channel.
15. Installs in a 3551001. Provides repeater function and LVDS interface allowing longer cable lengths and auto-termination when the 3551001 is powered off.
16. Attachment to wide ultra SCSI controllers limits operational speeds to Ultra SCSI (40 MBps) for cables up to two meters in length and Fast Wide (20 MBps) for cable lengths
between 2 meters and 4.3 meters. Ultra2 SCSI controllers and cables allow cable lengths up to 20 meters at up to 80 MBps.
17. Netfinity EXP200, 35301RU, includes a single 2 meter Ultra2 SCSI cable.
18. Netfinity 1000 is not available in the Americas.
19. Available in the US only.
115
CABLES - STORAGE UNITS CONTROLLERS
Appendix E: IBM Serial I/O
IBM Serial I/O Adapters
IBM Serial I/O Port Module
Serial I/O
PM16DB Port
Module
(P/N 37L1418)
Serial I/O
PM16RJ Port
Module
(P/N 37L1417)
IBM Serial I/O Multiplexer Sets
Serial I/O 16RJ Multiplexer Set
(P/N 37L1419)
•Multiplexer Interface Unit
•RJ Expansion Module
•Power Supply
•Test Cable
IBM Serial I/O SST8P
DB Adapter
(P/N 37L1414)
Customer Supplied
Unshielded
Two-Twisted Pair
Cable < 3500’ (1km)
IBM Serial I/O SST16P
RJ Adapter
(P/N 37L1415)
IBM Serial I/O Power Supply
Serial I/O 16DB Multiplexer Set
(P/N 37L1420)
•Multiplexer Interface Unit
•DB Expansion Module
•Power Supply
•Test Cable
Serial I/O PS4
Power Supply
(P/N 37L1421)
IBM Serial I/O SST16P
DB Adapter
(P/N 37L1423)
Customer Supplied
Unshielded
Two-Twisted Pair
Cable < 3500’ (1km)
Includes
IBM Serial I/O SST128P
two
Expandable Adapter 4’ (1.2 m)
(P/N 37L1416)
Cables
Sample Configurations
PS4
(P/N 37L1421)
4’ (1.2 m)
Cables
Four PM16DB
(P/N 37L1418)
SST128P
(P/N 37L1416)
PS4
(P/N 37L1421)
16DB
Multiplexer Set
(P/N 37L1420)
PM16RJ
(P/N 37L1417)
PM16DB
(P/N 37L1418)
Customer
Supplied
Unshielded
Two-Twisted Pair
Cable < 3500’ (1km)
116
16RJ
Multiplexer Set
(P/N 37L1419)
37L1414
Serial I/O SST8P DB Adapter1, 6
37L1415
Serial I/O SST16P RJ Adapter2, 6
37L1423
Serial I/O SST16P DB Adapter3, 6
37L1416
Serial I/O SST128P Expandable Adapter4, 6
37L1417
Serial I/O PM16RJ Port Module5
37L1418
Serial I/O PM16DB Port Module5
37L1419
Serial I/O 16RJ Multiplexer Set5, 7
37L1420
Serial I/O 16DB Multiplexer Set5, 7
37L1421
Serial I/O PS4 Power Supply5
(1) Intelligent serial I/O interface card providing eight DB-25 RS232 serial
connections using an octopus cable. Support for all ports at 921.6 Kbps
simultaneously.
(2) Intelligent serial I/O interface card providing sixteen RJ-45 RS232 serial
connections in a breakout box. Support for all ports at 115.2 Kbps simultaneously.
(3) Intelligent serial I/O interface card providing sixteen DB-25 RS232 serial
connections in a breakout box. Support for all ports at 115.2 Kbps simultaneously.
(4) Intelligent interface card providing up to 128 RS232 serial connections (DB25 or
RJ45) configured in 16 port increments utilizing any combination of Port Modules
and Multiplexer Sets. Includes two 4' (1.2 m) bus cables. Each 4' cable supports
attachment of 1 to 4 Port Modules and/or Multiplexer Interface Units for a total of 8
per adapter. The first Port Module or Multiplexer Set attached to a cable requires a
Serial I/O PS4 Power Supply (P/N 37L1421). Support for all ports at 115.2 Kbps
simultaneously.
(5) Port Modules and Multiplexer Sets attach directly to one the two standard 4'
(1.2m) bus cables of the Serial I/O SST128P Expandable Adapter (P/N 37L1416) or
directly to 1 or more Port Modules or Multiplexer Sets already attached to one of the
cables. A maximum of 4 Port Modules or Multiplexer Sets may be attached to a
single cable. The first Port Module or Multiplexer Set attached to a cable requires a
Serial I/O PS4 Power Supply (P/N 37L1421).
(6) Serial I/O Adapters are 32-bit PCI half length cards. A maximum of four Serial I/O
adapters (in any combination) may be installed in a single host system.
(7) Requires a customer supplied Unshielded Two-Twisted Pair (Catagory 3
minimum) cable with a maximum length of 3,500 feet (1 Km).
Important Notes
©IBM Personal Systems Group
Department K0LA
3039 Cornwallis Rd.
Research Triangle Park, NC 27709
Printed in the United States of America
01-00
All the part numbers referenced in this publication are product part numbers and not service part numbers.
This publication could contain technical inaccuracies or typographical errors. Changes are periodically made to the information herein; these
changes will be incorporated in new editions of this publication. IBM may make improvements and/or changes in the product(s) and/or
program(s) described in this publication at any time. IBM reserves the right to alter specifications and other product information without notice.
It is your responsibility to obtain the latest information.
Other part numbers in addition to those listed in this document may be required to support a specific device or function.
Data on competitive products is obtained from publicly obtained information and is subject to change without notice. Please contact the
manufacturer for the most recent information.
This IBM equipment is subject to applicable rules and regulations of the United States Federal Communication Commission (FCC).
The following items are trademarks or registered trademarks of IBM Corporation in the United States or other countries or both: AT, Flo Thru,
HelpWare, IBM, IntelliStation, LANStreamer, MWave, Netfinity, OS/2, Predictive Failure Analysis, SurePath, TechConnect,
WIN-OS/2, 800-CALL-IBM, ServerProven™.
TME 10 Netfinity is a trademark of Tivoli Systems, an IBM Company. Lotus, Lotus Notes and Lotus SmartSuite are trademarks of Lotus
Development Corporation.
Intel, Pentium Pro, Pentium II, MMX, and Xeon are trademarks or registered trademarks of Intel Corporation. Microsoft, Windows and Windows NT
are trademarks or registered trademarks of the Microsoft Corporation. UNIX is a registered trademark in the United States and other countries or
registered trademarks licensed exclusively through X/Open Company Limited. Trinitron is a trademark of the Sony Corporation. Java and
HotJava are trademarks of Sun MicroSystems, Inc. Adobe and PostScript are trademarks of Adobe Systems, Inc., APC is a trademark of
American Power Conversion, Inc. All other registered trademarks and trademarks are properties of their respective owners.
Updated 01/01/00
For the latest product & technical information, refer to the Information Sources on pages 1 and 2.
117
IMPORTANT NOTES
IBM reserves the right to change product specifications and to discontinue marketing products without notice.
*MHz only measures microprocessor internal clock speed, not application performance. Many factors affect application performance.
**When referring to hard drive capacity, GB stands for one billion bytes.Total user-accessible capacity may vary depending on operating
environments.
***The quotation function within ConfigXpert allows reseller specific pricing to be included.
****Tape Drives which utilize data compression technology have storage capacity that will vary depending upon whether the drive is operating in
native mode (without compression) or compressed mode. Actual storage capacity will vary based upon many factors and may be less than the
maximum possible.
Maximum internal hard disk drive capacities assume the replacement of any hard disk drives and the population of all hard disk drive bays with
the largest currently supported drives available from IBM.
The information contained in this document has not been submitted to any formal IBM test and is distributed AS IS. The use of this information
or the implementation of any of these techniques is a customer responsibility and depends on the customer’s ability to evaluate and integrate
them into the customer’s operational environment. While each item may have been reviewed by IBM for accuracy in a specific situation, there is
no guarantee that the same or similar results will be obtained elsewhere. Customers attempting to adapt these techniques to their own
environments do so at their own risk.
For more information on IBM’s statement of Limited Warranty, please call 1-800-772-2227 in the United States, 1-800-426-2255 in Canada, or
contact your IBM representative or reseller. Copies are available upon request.
For products with Lotus SmartSuite, depending on the product, SmartSuite may be pre-loaded, included on a CD, or available for order on a CD
at no charge. Diskettes and hard copy documentation available at an extra charge.
Energy Star compliance: The EPA, as a matter of policy, does not endorse any particular company or its products.
Unless otherwise stated, IBM makes no representations or warranties with respect to non-IBM products. Support (if any) for the non-IBM
products is provided by the third party, not IBM.
Unless otherwise noted, phone numbers and fax numbers are valid only in the United States. Outside the United States, please call your local
IBM for assistance.
Applications included in IBM products may vary from retail versions and may not include all documentation or functions. Not all products are
sold separately.
This publication was produced in the United States. IBM may not offer the products, services or features discussed in this document in other
countries, and the information is subject to change without notice. Consult your local IBM representative for more information on the products,
services and features available in your area.
Download PDF