Overview
The Tower UPS "G2" models are the next generation HP tower UPSs with USB support. These new UPSs are designed to provide
advanced power protection (or increased uptime and data corruption avoidance) for servers, storage, computer equipment, and
network environments.
Key benefits include increased power rating, intuitive front panel display, Enhanced Battery Management (EBM), prioritized shutdown, and hot-swappable batteries. Bundled with HP Power Manager management software, these UPSs also feature a serial and
USB ports for data exchange with the host computer, remote shut-down, a three-year warranty and a 60-day Battery Pre-Failure
Warranty.
T1000 G2 and T1500 G2
1. LED display
2. Battery Compartment
Models
HP T1000 UPS NA
HP T1000 UPS JPN/TWN
HP T1000 UPS INTL
HP T1500 UPS JPN/TWN
HP T1500 UPS INTL
AF403A
AF404A
AF405A
AF407A
AF408A
DA - 12506
Worldwide — Version 5 — March 30, 2008
Page 1
QuickSpecs
HP UPS T1000 G2, T1500 G2 Models
Overview
Kit Contents - UPS T1000
G2
HP UPS T1000 G2
Power Management Software CD
Power Products Documentation CD
6' (1.83 Meters) UPS to computer serial interface cable
6' (1.83 Meters) UPS to computer USB interface cable
NOTE: The International model includes 2 IEC to IEC power cords in addition to the above.
Kit Contents - UPS T1500
G2
HP UPS T1500 G2
Power Management Software CD
Power Products Documentation CD
6' (1.83 Meters) UPS to computer serial interface cable
6' (1.83 Meters) UPS to computer USB interface cable
NOTE: The International model includes 2 IEC to IEC power cords in addition to the above.
DA - 12506
Worldwide — Version 5 — March 30, 2008
Page 2
QuickSpecs
HP UPS T1000 G2, T1500 G2 Models
Product Highlights
NOTE: For a brief, printer friendly data sheet that describes this product and informs you of the essential capabilities and
specifications, please visit: http://h71028.www7.hp.com/ERC/downloads/4AA0-6982ENW.pdf.
Key Features
UPS T1000 G2 and
Manageability through USB port.
T1500 G2
Ease of configuration via enhanced front panel display.
Intelligent manageability with bundled Power Management software.
Long-term battery reliability with Enhanced Battery Management.
Hot-Swappable battery.
Enhanced system flexibility with independently controllable load
segment.
Backed by a three-year warranty, with the first year including parts and
labor and a 60-day HP Battery Pre-Failure Warranty. In North
America, it is covered by an additional $250,000 load protection
guarantee.
NOTE: Certain restrictions and exclusions apply. Consult the HP Computer
Support Center for details.
Easy Configuration via
Enhanced Front Panel
Display
Please see the line art drawing previously shown to identify the front panel with noted button functionality.
Investment Protection with HP UPSs incorporate Enhanced Battery Management; an exclusive, patented technology that doubles
Enhanced Battery
battery service life, optimizes battery recharge time, and provides advance notice of pending battery
Management
failure. With Enhanced battery Management, you have a lower overall cost of ownership and receive the
best in the industry protection for your critical equipment.
Intelligent Manageability HP UPSs ship with HP Power Manager management software, which enables you to monitor and control
HP UPSs locally or remotely. This software is a versatile, fully configurable, alert response tool that gives
system administrators a full overview of the network's conditions. It enables you to monitor system status
and power conditions, configure shut down timing, customize alert messages, and perform UPS
diagnostic checks quickly and easily.
Ease of Maintenance with HP UPSs are designed with hot-swappable batteries. With simple access through the front panel. Users
Hot-Swappable Battery
can safely install a new battery without ever powering down connected computer equipment.
Compatibility
Compatible with all HP computer systems and servers ranging from individual workstations to distributed
enterprise and other HP equipment (in tower form factor).
HP Quality
HP hardware qualification is the toughest in the industry. Extensive evaluation, testing, product
improvement, and an unsurpassed warranty guarantee the highest level of system protection, electrical
performance, product quality and compatibility.
DA - 12506
Worldwide — Version 5 — March 30, 2008
Page 3
QuickSpecs
HP UPS T1000 G2, T1500 G2 Models
Product Highlights
Warranty
HP UPSs are covered by a three-year warranty, with the first year including parts and labor. Also,
standard on all HP UPS units is our exclusive 60-day Battery Pre-Failure Warranty, which extends the
advantage of a HP three-year, limited warranty by applying it to the battery before it actually fails. This
warranty is offered worldwide. Specifically, the Pre-Failure Battery Warranty ensures that when customers
receive notification from HP Power Management Software that the battery may fail, the battery is replaced
free of charge under the warranty.
NOTE: $250,000 Computer/Load Protection Guarantee is also provided (applicable in North America
only).
DA - 12506
Worldwide — Version 5 — March 30, 2008
Page 4
QuickSpecs
HP UPS T1000 G2, T1500 G2 Models
Service and Support, Care Pack and Warranty Information
HP Care Pack Installation
Care Pack services provide a range of life cycle support options that let you choose the service levels that meet your business
requirements, from basic to mission-critical.
A full range of HP Care Pack hardware and software services are available including:
Installation and start up
Education courses
Extended onsite hardware coverage hours from same business day 13 hours, 5 day to 24 hours, 7 days call window with
options including 4 hour response or 6-hour Call To Repair
Comprehensive range of software technical support for Microsoft, Linux, ProLiant Essentials and VMware-based IT solutions
helping to deliver high level of application availability. Response times range from 30 mins for critical problems to 2 hours.
System Management, Performance Services and Mission Critical Support Solution.
NOTE: For more information on HP Care Pack services, contact any of our worldwide sales offices, resellers or visit our worldwide
website at: http://www.hp.com/hps/carepack
NOTE: For more complete information on HP Services offerings, customers and resellers, please visit is at: http://www.hp.com/hps
NOTE: Additional information regarding worldwide limited warranty and technical support is available at:
http://h18004.www1.hp.com/products/servers/platforms/warranty/index.html
NOTE: For additional information on Server Services, Rack and Power Options, please visit:
http://h20219.www2.hp.com/services/cache/111072-0-0-225-121.html
NOTE: The information contained herein is subject to change without notice and is provided "as is" without warranty of any kind.
NOTE: The warranties for HP products and services are set forth in the express limited warranty statements accompanying such
products and services.
Warranty Upgrade
Options
Response – Upgrade on-site response from next business day to same day 4-hours
Coverage – Extend hours of coverage from 5 days x 9 hours to 7 days x 24 hours
Duration – Select duration of coverage for a minimum period of 1 year or multiple years
HP Care Pack Information For additional HP Care Pack (hardware & software) information, as well as orderable part numbers,
please refer to the URL listed below:
http://h18005.www1.hp.com/services/carepaq/index.html
DA - 12506
Worldwide — Version 5 — March 30, 2008
Page 5
QuickSpecs
HP UPS T1000 G2, T1500 G2 Models
Related Options
Service & Support (Care
Pack)
Hardware Installation (Electronic)
DA - 12506
Worldwide — Version 5 — March 30, 2008
U4690E
Page 6
QuickSpecs
HP UPS T1000 G2, T1500 G2 Models
Technical Specifications
UPS T1000 G2 Specifications
Low-Voltage Models
T1000 G2
AF403A (NA)
AF404A (JPN/TWN)
High-Voltage Models
T1000 G2
AF405A (INTL)
Unit Dimensions (WxHxD) 10.25 x 6.75 x 14 (inch)
260.35 x 171.45 x 355.6 (mm)
17.44 x 11.31 x 14.50 (inch)
Shipping Dimensions
442.98 x 287.27 x 368.3 (mm)
36 lbs (16.33kg)
Unit Weight
41 lbs (18.60 kg)
Shipping Weight
T1000G2, NA (AF403A)
120V
Operating Voltage
Settings
1000/650
Power Out (VA/Watts)
5-15P (attached cord)
Input Connection
(8) 5-15R
Output Connection
1
Load Segments
NOTE: Part Number AF403A is user selectable for 100V, 110V, or 120V via dip switch setting on the
back of the unit.
T1000 G2, JPN/TWN (AF404A)
100V, 110V
Operating Voltage
Settings
1000/650
Power Out (VA/Watts)
5-15P (attached cord)
Input Connection
(8) 5-15R
Output Connection
1
Load Segments
NOTE: Part Number AF404A is user selectable for 100V, 110V, or 120V via dip switch setting on the
back of the unit..
T1000 G2, INTL (AF405A)
230V
Operating Voltage
Settings
1000/650
Power Out (VA/Watts)
IEC 320 C14 input connector
Input Connection
(8) IEC 320 C13
Output Connection
1
Load Segments
NOTE: Part Number AF405A is user selectable for 220V, 230V, or 240V via dip switch setting on the
back of the unit.
DA - 12506
Worldwide — Version 5 — March 30, 2008
Page 7
QuickSpecs
HP UPS T1000 G2, T1500 G2 Models
Technical Specifications
UPS T1500 G2 Specifications
Low-Voltage Models
T1500 G2
AF407A (JPN/TWN)
High-Voltage Models
T1500 G2
AF408A (INTL)
Unit Dimensions (WxHxD) 10.25 x 6.75 x 14 (inch)
260.35 x 171.45 x 355.6 (mm)
17.44 x 11.31 x 14.50 (inch)
Shipping Dimensions
442.98 x 287.27 x 368.3 (mm)
45 lbs (20.41kg)
Unit Weight
50 lbs (22.68 kg)
Shipping Weight
T1000 G2, JPN/TWN (AF407A)
100V
Operating Voltage
Settings
1500/900
Power Out (VA/Watts)
Attached 6' power cord with NEMA 5-20P
Input Connection
(8) 5-15R
Output Connection
1
Load Segments
NOTE: Part Number AF407A is user selectable for 100V, 110V, or 120V via dip switch setting on the
back of the unit.
T1500 G2, INTL (AF408A)
230V
Operating Voltage
Settings
1500/900
Power Out (VA/Watts)
IEC 320 C14 input connector
Input Connection
(8) IEC 320 C13
Output Connection
1
Load Segments
NOTE: Part Number AF408A is user selectable for 220V, 230V, or 240V via dip switch setting on the
back of the unit.
HP UPS T1000, T1500 G2 Models Specifications
Electrical Input
Electrical Output
Battery
Voltage Range
Frequency
Connections
Online Efficiency
Surge Suppression
Online Regulation
On battery Regulation
Voltage Wave Form
Connections
Output Protection
Type
Recharge Time
Battery String Voltage
DA - 12506
100V, 120V, 208V, and 230V models
See Model Specifications for nominal and user selectable voltage settings
50/60 Hz
See Model Selection Matrix
95%
High Energy 6500A peak
-30% to +20% of nominal voltage
±5% of nominal voltage
Sine wave
See Model Specifications
Re-settable circuit protectors (T1500 models only)
Maintenance-free, sealed, valve-regulated lead acid (VRLA)
<4 hours to 90% usable capacity; <24 hours for complete recharge
T1000 G2: 24V (2x12V)
T1500 G2: 36V (3X12V)
Worldwide — Version 5 — March 30, 2008
Page 8
QuickSpecs
HP UPS T1000 G2, T1500 G2 Models
Technical Specifications
Battery Ampere Hour (ah) T1000 G2: 9ah
T1500 G2: 9ah
Communications
Standard communication port (ships with 6' Serial communication cable)
Serial Ports
Standard communication port (ships with 6' USB communication cable)
USB Port
Power On/Standby button
LED Indicators
Power LED
Voltage correction LED
Output Load Level LED
Red - Maximum load
Amber - Medium load
Green - light load
Battery Charge LED
Power LED is Green
Red-The batteries are beginning to charge.
Amber-The batteries are midway through charging.
Green-The batteries are fully charged.
Power LED is flashing green
Red-The batteries have a low level of energy.
Amber-The batteries have a medium amount of energy.
Green-The batteries have a high amount of energy.
Battery Warning LED
Mute/Test Button
Environmental and Safety Operating Temperature 50° to 104° F (10° to 40° C)
-13° to 131° F (-25° to 55° C)
Transit and Storage
Temperature
20% to 80% (non-condensing)
Humidity (Operation)
5% to 95%
Humidity
(Non-operating)
Up to 6,600 ft (2000 m) above sea level
Operating Altitude
Up to 49,000 ft (15,000 m) above sea level
Transit and Storage
Altitude
Less than 53 dBA max
Audible Noise
Please see table below
Safety Markings
Please see table below
EMC Markings
FCC CFR 47, Part 15 Class A, EN50091-2
Emissions
IEC 801-2, IEC 801-3, IEC 801-4, IEC 801-5
Immunity
Conforms to IEEE 587B and ANSI C62.41
Surge Suppression
DA - 12506
Worldwide — Version 5 — March 30, 2008
Page 9
QuickSpecs
HP UPS T1000 G2, T1500 G2 Models
Technical Specifications
Safety Markings
DA - 12506
Worldwide — Version 5 — March 30, 2008
Page 10
QuickSpecs
HP UPS T1000 G2, T1500 G2 Models
Technical Specifications
EMC Markings
Estimated Backup Times Chart (In Minutes)
T1000 G2
Load, percent
Load, Watts
20%
50%
80%
100%
130
325
520
650
DA - 12506
Estimated battery runtime at 100% battery
charge
45 minutes
15 minutes
6 minutes
4 minutes
Worldwide — Version 5 — March 30, 2008
Page 11
QuickSpecs
HP UPS T1000 G2, T1500 G2 Models
Technical Specifications
T1500 G2
Load, percent
Load, Watts
20%
50%
80%
100%
210
525
840
1050
Estimated battery runtime at 100% battery
charge
45 minutes
15 minutes
6 minutes
4 minutes
NOTE: Backup times are estimated for typical applications. Actual performance will depend on load and battery conditions.
Environment-friendly
Products and Approach
End-of-life Management
and Recycling
Hewlett-Packard offers end-of-life HP product return, trade-in, and recycling
programs in many geographic areas. For trade-in information, please go to
http://www.hp.com/go/green. To recycle your product, please go to:
http://www.hp.com/go/green or contact your nearest HP sales office.
Products returned to HP will be recycled, recovered or disposed of in a
responsible manner.
The EU WEEE directive (2002/95/EC) requires manufacturers to provide
treatment information for each product type for use by treatment facilities.
This information (product disassembly instructions) is posted on the Hewlett
Packard web site at: http://www.hp.com/go/green. These instructions may be
used by recyclers and other WEEE treatment facilities as well as HP OEM
customers who integrate and re-sell HP equipment.
© Copyright 2009 Hewlett-Packard Development Company, L.P.
The information contained herein is subject to change without notice.
Microsoft and Windows NT are US registered trademarks of Microsoft Corporation. Intel is a US registered trademark of Intel
Corporation. Unix is a registered trademark of The Open Group.
The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and
services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial
errors or omissions contained herein.
DA - 12506
Worldwide — Version 5 — March 30, 2008
Page 12
Download PDF