Ampair 600 230V Wind Turbine Brochure

Add to my manuals
4 Pages

advertisement

Ampair 600 230V Wind Turbine Brochure | Manualzz

Uniclass

L74214

CI/SfB

(61.7)

Date of publication

1 January, 2008 x

EPIC

K211

(H17)

®

Ampair 600

for home, work and school www.ampair.com

®

2

Ampair

®

600 wind turbine.

24 V battery charging or 230 V grid connection

The Ampair 600 is the latest micro wind turbine from Ampair. Built on the same platform as the renowned Ampair 100 and the newer Ampair 300 it has a 1.7m diameter blade optimized for low and medium speed winds. It incorporates the PowerFurl™ system first seen in the Ampair 300 which slows the turbine down in high winds, reducing noise and mounting system loads. It is available in two versions depending on whether the need is for high capacity 24V battery charging or for 230V grid connection. It can be used on land or on larger vessels and, like all Ampair products, is built to full marine grade specifications.

A. Ampair

®

600W battery charge wind turbine.

The Ampair 600-24 is a small wind turbine with 1.7m diameter blades that can be used with 24V DC battery systems.This battery charge version includes the turbine ‘head’ plus the regulator. It also needs an appropriate

24V battery bank to store the energy and suitable 24V loads.

A06 1024 A600-24 system

A

B

Ampair 600 on brick wall mount

B. Ampair

®

600W grid tie wind turbine

The Ampair 600-230 is a small wind turbine with 1.7m diameter blades that can be used to feed power back into the 230V mains electrical supply so that the premises need to purchase less power from the grid. This grid-tie system includes the turbine ‘head’ plus the necessary G83 inverter. A mounting system and installation services are also required, and monitoring systems are available for educational use.

A0620230 A600-230 system

C. Ampair

®

mounting systems

These six mounting systems suit a variety of situations.

A06 M00 BWM: brick wall mount

A06 M10 SFM: steel frame mount

A06 M50 TUM: tilt up mast (8m)

A06 M70 GM: guyed mast (12m)

A06 M20 NPRM: non penetrating roof mount

A06 M60 TPM: telegraph pole mount

Ampair 600 on telegraph pole mount

C

D. Ampair

®

monitoring systems

The powerful combination of the Ampair 600 with an anemometer, a wind vane and a data logger brings renewables generation alive. Using a standard network port and internet connection, the logger uploads energy and weather data automatically to the

Ampair Net website for sharing of by authorised users, such as teachers, pupils and facilities managers, of performance & CO2 graphs.

Price includes 3-year website hosting fee.

See www.ampair.com/ampair/ampnet.asp for an example.

ME AN10 Data logger set & Ampair Net Ampair 600 on tilt up mast

D

E. Ampair

®

installation service

Specialist Ampair-approved contractors should be used. Prices for more complex situations require quotation after a survey.

A06 S00 Site survey

A06 S10 Basic install

A06 S40 Complex install

Clear Skies product WT5033

Clear Skies installer 2142847

Ampair ®

Net web display

24 or 48 V battery charging

230 V grid connection

Cut-in windspeed

Cut-out windspeed

Maximum power

Maximum voltage

Maximum current

Power form

Power input

Rotor swept area

Generator output

Turbine diameter

Overspeed control

Weight

Construction

Generator

Noise

Longevity

24 V DC battery charge

Reference power at 11.0m/s (24.6mph) 723 W (into battery)

Reference annual energy at 5.0 m/s 1300 kWh/yr; 48 kAh/yr

3.0 m/s n/a

1050 W

24 V nominal

30 A

24 V DC

<0.5 W

48 V DC

battery charge

741 W (into battery)

1394 kWh/yr;25 kAh/yr

230 V AC

grid connected

698 W (into grid)

1232 kWh/yr (to grid)

3.0 m/s n/a

1140 W

3.0 m/s n/a

730 W

230 V nominal 48 V nom inal

17 A

48 V DC

<0.5 W

2.27m

2

3-phase AC (to external rectifier)

1.70 m

3.2 A

230 V AC single phase 50Hz

0.1 W sleep, <4 W standby

Blade pitch control and dump load

16.0 kg (turbine h ead including blades & tail fin) powder coated die cast aluminium body; 3 blades of GRP construction direct drive NeFeBr permanent magnet generator producing three phase

Max 1-3 dBA above background

Expected 15 ye ar operational life

2,500

2,000

1,500

1,000

500

0

0

Ampair 600-24

20

10 turbulence will reduce power

1 2 3 4 5

Average Windspeed (m /s)

6 7

0

80

70

60

50

40

30

800

700

600

Ampair 600-24

500

400

300

200

100

0

0 2 4

25

20

15

10

5 turbulence will reduce power

6 8 10 12 14

0

Windspeed (m /s)

2,500

Ampair 600-48

2,000

40

30

1,500

20

1,000

10

500

0

0 1 turbulence will reduce power

2 3 4 5 6 7

0

Average Windspeed (m /s)

2,500

Ampair 600-230

2,000

1,500

1,000

500

0

0 1 turbulence will reduce power

2 3 4 5

Average Windspeed (m /s)

6 7

800

700

600

Ampair 600-48

500

400

300

200

100

0

0 2

14

12

10

8

6

4

2

4 turbulence will reduce power

6 8 10 12 14

0

Windspeed (m /s)

300

200

100

0

0

800

700

600

500

400

Ampair 600-230

2

25

20

15

10

5

4 turbulence will reduce power

6 8 10 12 14

0

Windspeed (m /s)

ø1700mm

3

Conformity: the following standards:

• G83/1: Recommendations for the connection of small-scale embedded generators (up to 16A per phase) in parallel with public low-voltage distribution networks.

• BS EN 61400 part 2 (1996): Wind turbine generator systems: Design requirements of small wind systems

• BS EN IEC 60335-1 (1994): Safety Of Household Electrical

Appliances

• LV Directive 73/23/EC: EU Low Voltage Directive

• WEEE Directive 2002/96/EC: EU Waste Electrical & Electronic

Equipment Directive

• RoHS Directive 2002/95/EC: EU Restriction of Hazardous

Substances Directive

• EMC Directive 89/336/EC: EU Electromagnetic Compatibility

Directive.

1. Power Curves and Annual Energy: The performance of wind turbine systems is impossible to predict with any certainty due to the variability in the wind from location to location and from year to year. These estimates are based upon the best available information but are given as guidance only and should not be considered as a guarantee. For a greater level of certainty we would recommend on-site wind speed monitoring for at least a year.

2. Variation: All values are nominal as there will be some variation in manufactured product.

3. Lifetime: Expected safe operational life excluding consumable items. Actual life will depend on local conditions. Note warranty period is different.

4. Terms and conditions apply

5. Specifications subject to change.

www.ampair.com [email protected] tel: +44 (0)845 389 0660 fax: +44 (0)1344 303 312

Ampair, Park Farm, Warfield, Berkshire RG42 5RH, UK

© Ampair 2008 ® Ampair and Aquair are registered trade marks

®

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement