INSTALLATION INSTRUCTIONS

FOR SSB/SSP STEAM GENERATOR KITS, ASD & LS GENERATORS, TT CONTROL

*****CUSTOMER WARNINGS*****

• DO NOT USE THIS PRODUCT UNLESS YOU HAVE CONSULTED YOUR DOCTOR AND RECEIVED WRITTEN

PERMISSION TO DO SO. USE OF THIS PRODUCT MAY BE HAZARDOUS TO YOUR HEALTH.

• STEAM IS HOT! DO NOT TOUCH OR GO NEAR THE STEAM HEAD FROM THE TIME THE UNIT IS “ON”, UP TO ONE

HOUR FROM THE TIME THE UNIT IS OFF. SEVERE BURNS WILL OCCUR IF YOU COME IN CONTACT WITH THE

STEAM HEAD OR STEAM EMITTING FROM THE STEAM HEAD.

• NEVER ATTEMPT TO FILL AROMA THERAPY RESERVOIR ON THE STEAM HEAD WHEN UNIT IS IN THE “ON”

POSITION. SEVERE BURNS WILL OCCUR.

• DO NOT USE THERMASOL AROMA THERAPY OILS OR SKIN CARE PRODUCTS OR ANY PRODUCT IN

CONJUNCTION WITH YOUR STEAM SUITE UNIT WITHOUT CONSULTING WITH YOUR ALLERGIST OR DOCTOR

BEFORE USE. THESE PRODUCTS MAY BE HAZARDOUS TO YOUR HEALTH.

• YOUR SHOWER MAY BE A SLIP AND FALL HAZARD. CHECK WITH YOUR CONTRACTOR OR FLOORING

MANUFACTURER REGARDING THE SAFE USE OF YOUR FLOORING IN A STEAM APPLICATION. SLIPPING AND

FALLING INTO THE STEAM HEAD ITSELF OR INTO THE STREAM OF STEAM EMITTING FROM THE STEAM HEAD

WILL CAUSE SERIOUS BURNS OR PHYSICAL INJURY.

• DO NOT USE STEAM ROOM WHILE UNDER THE INFLUENCE OF ALCOHOL OR DRUGS, AS THIS CAN BE

HAZARDOUS TO YOUR HEALTH.

• IF YOU ARE FEELING UNCOMFORTABLE, DIZZY, FAINT, OR STARTING TO FALL ASLEEP, IMMEDIATELY EXIT THE

STEAM ROOM.

• DO NOT USE STEAM ROOM IF YOU ARE UNDER THE AGE OF 16 UNLESS SUPERVISED BY AN ADULT.

• STEAM SUITE GENERATORS ARE FOR INDOOR USE ONLY. THEY SHOULD NEVER BE LOCATED OUTSIDE THE

HOME.

• STEAM SUITE GENERATORS ARE NOT TO BE USED FOR SPACE HEATING PURPOSES.

• FOR SAFETY, SMOOTH OPERATION PRACTICE AND LIABILITY. IF YOU ARE A PLUMBER/INSTALLER, PLEASE

ENSURE THIS OWNERS MANUAL & WARRANTY INFORMATION IS IN THE OWNER’S POSSESSION WITH SPECIFIC

DELEGATION FOR THE PURPOSE OF COMPLETELY FAMILIARIZING ANY USERS WITH THIS OR ANY STEAM SUITE

PRODUCT.

FAILURE TO FOLLOW INSTALLATION INSTRUCTIONS SPECIFICALLY WILL CAUSE THE WARRANTY TO BE VOID.

Note: For better technical assistance and before contacting Technical Support, please have this model number and serial number ready

PLACE SERIAL # HERE

TECHNICAL AND WARRANTY SUPPORT ONLY: 1-800-776-0711

FOR ALL OTHER CUSTOMER SUPPORT PLEASE CONTACT YOUR DEALER

1 OF 14 Rev N/C 3/09 SAS DOC NO. 81157

SIZING YOUR STEAM ROOM

1. Calculate the total volume of the enclosure. (Length x Width x Height = Total Volume).

2. Using the Volume total, simply select the SSB or SSP kit that corresponds to the room size. For instance, a room 4’ wide x 6’ deep x 8 high equals 192 cubic feet.

3. Select a SSB or SSP-240 kit in your desired finish.

NOTE: for rooms taller than 8 feet in height you must go to the next larger size kit for every extra foot.

Kit or Generator Model Stm Rm Size

(cu. ft.)

SSB-ACR / LS-65

SSB-84 / LS-90

ACRYLIC*

84

SSB-140 / LS-130

SSB-240 / LS-235

140

240

SSP-ACR / ASD-100

SSP-84 / ASD-150

SSP-140 / ASD-300

SSP-240 / ASD-450

ACRYLIC*

84

140

240 kW

3.5

6

8

10

3.5

6

8

10

*ACRYLIC MODULE MUST BE APPROVED FOR STEAM BY MODULE MANUFACTURE.

HEIGHT

LENGTH

WIDTH

DOC NO. 81157 2 OF 14 Rev N/C 3/09 SAS

Tools Needed

Generator Installation Instructions

9 Pipe wrench

9 Tubing cutter

9 Wire cutters or wire strippers

9 Adjustable wrench

9 Screwdrivers (phillips & regular)

Parts Enclosed

9 Steam generator

9 Control kit (Included)

9 50 foot control cord

9 Steam head (Included)

9 Waterfeeder screen kit

9 Installation instructions w/ warranty form 9 Solder & flux

9 1” & 1-1/16” masonry drill bits

9 Drill motor

9 Propane torch

9 Other tools as required

Materials Needed

9 Brass ball valve

9 Pipe compound

9 In-line filter (recommended)

9 Wire (Hardwired units only)

MANUAL POWER FLUSH VALVE

FOR ASD MODEL ONLY

(SHOWN OPEN)

9 Wire cap nuts (Hardwired units only)

9 Flex conduit (Hardwired units only)

9 Brass or copper tee connection & plug

9 Copper tubing or pipe with various fittings

9 Silicone

ELECTRICAL J-BOX

CONNECTIONS

WATER INLET

ELECTRICAL

SPECIFICATION

WATER INLET

INNER TANK

DRAIN

DOC NO. 81157

STEAM OUTLET

ASD and LS GENERATORS

SMITTY PAN PLUMB

TO OUTSIDE DRAIN

3 OF 14 Rev N/C 3/09 SAS

:::NOTICE :::

YOU MUST ATTACH STATIC CLING USER WARNING LABEL IN THE SHOWER NEXT TO THE

CONTROL UPON COMPLETION OF INSTALLATION.

Warning label

VANITY

6” MAX

Steam head

12” MIN

16” MAX

Approx 60”

CLOSET

Shower floor

BASEMENT

!!!! IMPORTANT !!!!

LOCATE THE STEAM HEAD 12” OFF THE SHOWER FLOOR OR BATHTUB RIM AND 6” FROM

ANY CORNER. STEAM HEAD IS TO BE MOUNTED AS FAR AS POSSIBLE FROM TYPICAL

BATHING POSITION (SEATED OR STANDING) AND AS FAR FROM CONTROL AS POSSIBLE

WHILE MAINTAINING APPROXIMATELY A 60” CONTROL HEIGHT.

DOC NO. 81157 4 OF 14 Rev N/C 03-09 SAS

Requirements for Proper Installation

1. Ensure the enclosure to be used is vapor-proof. It should have a vapor-proof door that seals well so the steam does not escape. Make sure the wall, ceiling and the floor materials are okay to use with steam and hot condensation that any steam generator produces.

2. Use copper or brass fittings only. (NEVER USE GALVANIZED OR IRON PIPE FITTINGS)

3. MAXIMUM INLET WATER PRESSURE NOT TO EXCEED 70 P.S.I.

4. For the water inlet and steam outlet use a brass union for easy installation. You must Install the drain/spill pan under the unit for SSB/LS models. ASD models come pre-equipped with a drain pan. All drain pans must be plumbed to an approved drain.

5. The generator must be upright, accessible and on a level surface with all connections in the appropriate position; water inlet, steam outlet (see pg 3). Front and rear access panels must be unobstructed and allow for easy access.

6. Unit may be installed up to 50 feet away from shower area, in a dry well-ventilated area.

7. The steam line can run up, down, or horizontal; but cannot run down and then up. If it does, a steam trap may be produced at the low point blocking the flow of steam. Insulate the steam outlet piping if it exceeds 10 feet or is exposed to cold areas. NOTE: Use only steam rated insulation (225f min).

8. If unit is installed in a basement or attic, ensure that the unit and plumbing is well insulated and will not freeze.

9. Do relief valve into the steam line can be hazardous, should the steam outlet be capped off or obstructed.

10. Pitch steam line back towards generator and avoid perfectly level plumbed steam lines.

11. Before connecting water line to the generator, flush water line into a five-gallon pail to remove any silt or other materials that may be in the line. Then install supplied screen kit. An in-line water filter is also recommended.

12. Make sure water is turned on to the unit before operating the unit.

Water Inlet Installation

1. The generator must be mounted on a level surface able to support a minimum of 50 pounds.

2. MAXIMUM INLET WATER PRESSURE TO BE NO LESS THAN 15 P.S.I. AND NOT TO EXCEED 70 P.S.I.

3. Connect a tee to the cold water line. Install copper pipe to the tee. An in-line filter is recommended.

4. Install a brass shut-off valve on the water inlet line in an accessible area prior to the recommended in-line water filter.

13. Before connecting water line to the generator, flush water line into a five-gallon pail to remove any silt or other materials that may be in the line. Then install supplied screen kit. An in-line water filter is also recommended.

5. Make the final connection and turn on water. All ThermaSol generators are equipped with an automatic water fill system. The water will stop after unit is filled.

DOC NO. 81157 5 OF 14 Rev N/C 03-09 SAS

STEAM HEAD / LINE INSTALLATION

Parts Enclosed

9

9

Deluxe

Escutcheon head

Tools Needed

9 Pipe

9 7/8” cutting tool

9 Other tools as required

1. IMPORTANT NOTE! LOCATE THE STEAM HEAD 12” OFF THE SHOWER FLOOR OR BATHTUB RIM AND 6”

FROM ANY CORNER. STEAM HEAD IS TO BE MOUNTED FAR AS POSSIBLE FROM TYPICAL BATHING

POSITION (SEATED OR STANDING) AND AS FAR FROM CONTROL AS POSSIBLE WHILE MAINTAINING

APPROXIMATELY A 60” CONTROL HEIGHT.

2. Drill a 7/8” diameter hole in the shower wall or wall above the bathtub for the steam outlet line.

3. Connect 1/2” brass union onto the steam outlet of generator.

4. Run a 1/2” copper pipe or tubing (free of any kinks) from the union to the 7/8” hole in wall.

5. Attach the steam head and escutcheon to the copper pipe. CAUTION: Do not obstruct the steam line with any

shut-off valves, plugs or caps. ALL STEAM SUITE generators are designed to build NO PRESSURE.

6. The steam line can run up, down, or horizontal; but cannot run down and then up or is exposed to cold areas. NOTE: Use steam rated insulation (225f min).

. If it does, a steam trap will be produced at the low point blocking the flow of steam. Insulate the steam outlet piping if the piping run exceeds 10 feet

WARNING: Avoid contact with steam head! It will burn you. Avoid direct contact with the steam coming out of the steam head! It is extremely hot! It will burn you!

DOC NO. 81157 6 OF 14 Rev N/C 03-09 SAS

Electrical Installation

NOTE: All electrical wiring must be done per National/Local Electrical Codes.

Steam Suite requires that a licensed electrician perform all electrical work.

NOTE: USE COPPER WIRE ONLY.

Wire sizes recommended by NEC (2002 Version). Minimum wire temperature rating 90 °C. Type THHN.

Kit or Generator

Model

SSB-ACR / LS-65

SSB-84 / LS-90

SSB-140 / LS-130

Wire

Gauge

10

10

8

Breaker

Size

20

30

40

Stm Rm Size

(cu. ft.)

ACRYLIC

84

140 kW

3.5

6

8

SSB-240 / LS-235

SSP-ACR / ASD-100

SSP-84 / ASD-150

SSP-140 / ASD-300

8

10

10

8

50

20

30

40

240

ACRYLIC

84

140

10

3.5

6

8

SSP-240 / ASD-450 8 50 240 10

Electrical Questions? Call (800) 585-STEAM for Technical Support

1. Turn off all electricity to the working area at the main breaker panel!

2. Connect 240-volt SINGLE PHASE AC electrical lines to wires labeled 1 & 2 in junction box on the generator and an approved ground to the green safety grounding wire.

DOC NO. 81157 7 OF 14 Rev N/C 03-09 SAS

CONSUMER WARNING

DO NOT USE THIS PRODUCT UNLESS YOU HAVE

CONSULTED WITH YOUR

DOCTOR

AND RECEIVED WRITTEN PERMISSION TO DO SO. USE OF THIS

PRODUCT MAY BE HAZARDOUS TO YOUR HEALTH.

PLEASE CONSULT YOUR PHYSICIAN

BEFORE USING. IF YOU ARE PREGNANT,

ELDERLY, HAVE HIGH BLOOD PRESSURE, DIABETES, SUFFERING FROM

HEART DISEASE, INTOXICATED, OR NOT IN GOOD HEALTH, DO NOT USE THIS

STEAM BATH.

STEAM IS HOT!

DO NOT TOUCH OR GO NEAR THE STEAMHEAD FROM THE

TIME THE UNIT IS “ON”, UP TO ONE HOUR AFTER IT HAS SHUT OFF. SEVERE

BURN WILL OCCUR IF YOU COME IN CONTACT WITH THE STEAMHEAD OR

STEAM EMITTING FROM THE STEAMHEAD.

NEVER ATTEMPT

TO FILL AROMA RESERVOIR ON THE STEAMHEAD WHEN

UNIT IS IN THE

ON

POSITION. SEVERE BURNS WILL OCCUR.

DO NOT

USE THERMASOL AROMATHERAPY OILS OR SKIN CARE PRODUCTS

OR ANY PRODUCT ASSOCIATED WITH YOUR THERMASOL UNIT WITHOUT

CONSULTING WITH YOUR ALLERGIST OR DOCTOR BEFORE USE. THESE

PRODUCTS MAY BE HAZARDOUS TO YOUR HEALTH.

DO NOT

USE STEAM ROOM WHILE UNDER THE INFLUENCE OF ALCOHOL OR

DRUGS, AS THIS CAN BE HAZARDOUS TO YOUR HEALTH.

YOUR SHOWER MAY BE A

SLIP-AND-FALL HAZARD

. CHECK WITH YOUR

CONTRACTOR OR FLOORING MANUFACTURER REGARDING THE SAFE USE

OF YOUR FLOORING IN A STEAM APPLICATION. SLIPPING AND FALLING INTO

THE STEAMHEAD ITSELF OR INTO THE STREAM OF STEAM EMITTING FROM

THE STEAMHEAD WILL CAUSE SERIOUS BURNS, OR PHYSICAL INJURY.

IF YOU ARE FEELING

UNCOMFORTABLE, DIZZY, FAINT,

OR STARTING TO

FALL ASLEEP

IMMEDIATELY

EXIT

THE STEAM ROOM.

DO NOT USE STEAM ROOM

IF YOU ARE UNDER THE AGE OF 16 UNLESS

SUPERVISED BY AN ADULT.

THERMASOL STEAM BATH GENERATORS ARE

NOT

DESIGNED TO BE USED

FOR

SPACE HEATING PURPOSES.

THERMASOL STEAM BATH GENERATORS

ARE FOR

INDOOR USE ONLY.

THEY SHOULD NEVER BE LOCATED OUTSIDE

THE HOME.

DOC NO. 81157 8 OF 14 Rev N/C 03-09 SAS

Powerflushing Your SSP/ASD Steam Generator System

DOC NO. 81157

CLOSE / OFF

OPEN / ON

(SHOWN)

“OPEN” ACTIVATES THE

POWERFLUSH CYCLE.

“CLOSED” SHUTS IT OFF

1. Power on the control and set the timer to 45 minutes.

2. Open the powerflush ball valve located on top of the generator (refer to Figure 1) for 5-7 minutes, then close.

3. Allow generator to finish the 45-minute STEAM session.

** ThermaSol recommends one powerflush cycle after every fifty uses. This may increase due to local water conditions. Contact your local waterworks for info about water hardness in your area.**

Warning: IT IS IMPORTANT THAT NO ONE BE INSIDE THE SHOWER ENCLOSURE

DURING THE POWERFLUSH CLEANING CYCLE. IT IS ALSO IMPORTANT THAT THE

ENCLOSURE DOOR BE CLOSED DURING THIS CYCLE.

Warning: Exit shower area once the powerflush is started, hot water from Steamhead can burn you. Keep the steam door on the enclosure closed during this cycle.

9 OF 14 Rev N/C 03-09 SAS

TT Control Installation

&

Operating Instructions

WARNING

DO NOT USE THIS PRODUCT UNLESS YOU HAVE CONSULTED YOUR DOCTOR AND RECEIVED WRITTEN PERMISSION TO DO SO. USE OF THIS PRODUCT MAY BE

HAZARDOUS TO YOUR HEALTH.

STEAM IS HOT! DO NOT TOUCH OR GO NEAR THE STEAM HEAD WHEN THE UNIT IS IN THE “ON” POSITION. SEVERE BURN WILL OCCUR IF YOU COME IN CONTACT

WITH THE STEAM HEAD OR STEAM EMITTING FROM THE STEAM HEAD.

NEVER ATTEMPT TO FILL AROMA THERAPY RESERVOIR ON THE STEAM HEAD WHEN UNIT IS IN THE “ON” POSITION. SEVERE BURNS WILL OCCUR.

DO NOT USE THERMASOL AROMA THERAPY OILS OR SKIN CARE PRODUCTS OR ANY PRODUCT IN CONJUNCTION WITH YOUR THERMASOL UNIT WITHOUT

CONSULTING WITH YOUR ALLERGIST OR DOCTOR BEFORE USE. THESE PRODUCTS MAY BE HAZARDOUS TO YOUR HEALTH.

• YOUR SHOWER MAY BE A SLIP AND FALL HAZARD CHECK WITH YOUR CONTRACTOR OR FLOORING MANUFACTURER REGARDING THE SAFE USE OF YOUR

FLOORING IN A STEAM APPLICATION. SLIPPING AND FALLING INTO THE STEAM HEAD ITSELF OR INTO THE STREAM OF STEAM EMITTING FROM THE STEAM HEAD

WILL CAUSE SERIOUS BURNS, OR PHYSICAL INJURY.

Headquarters & Technical Support

2255 Union Place, Simi Valley, CA 93065 – (800) 776-0711 www.thermasol.com

DOC NO. 81157 10 OF 14 Rev N/C 03-09 SAS

TT Installation Instructions

1. The TT digital control must be located inside the shower area.

2. Install the touch pad 4 to 6 feet from the floor inside the steam room. Drill a 1-1/16” hole in the wall.

3. Bring the control cable from the generator through the 1-1/16” hole. Using the coupler, connect the cable to the touch pad connector. Ensure the coupler is located higher in the wall than the control.

Do not pinch, nail, or wedge the control cable. Any damage to the control cable could result in the control not working properly. If the control is not installed immediately, protect the end connector with tape or some other kind of shielding material.

4. Connect the other end of the control cable to the generator BEFORE turning power on to the generator.

5. Turn on both water and power to the generator.

6. Test the touch pad to ensure it is properly connected. If any problems arise, call 800-776-0711.

7. THESE STEPS MUST BE TAKEN OR YOUR WARRANTY WILL BE VOID. Coat the entire control back with supplied waterproof silicon. Completely seal the control to the wall so moisture does not get behind it. Place the control on the wall pressing firmly. You may need to tape the control into place until the silicone dries. Be careful not to harm the wall and/or control with the tape. (Figure 1)

Let dry for 24 hours before using steam bath.

Failure to follow installation instructions specifically will cause the warranty to be void!

1-1/16” hole in wall for control wire

Completely cover the entire back with supplied waterproof silicone.

50 ft. control wire from steam generator

Figure 1

DOC NO. 81157 11 OF 14 Rev N/C 03-09 SAS

TT Control Operating Instructions

1. Starting Your Steam Bath. Press the “Control Button” momentarily to activate your steam bath session. Your control will come from the factory with a default setting of 60 minutes at

100 °F (to change these settings move to steps 2 and 3) once the button is pressed you will see a green LED appear indicating the time to be set, four seconds will pass and a red LED will appear indicating the temperature to be set.

Note: Green LED’s indicate the time and the red LED’s indicate the temperature.

Control Button

Figure 2

2. Changing Session Time. While the green LED is still flashing (within 4 seconds), momentarily press the “Control Button”. Repeat until the green LED associated with your desired time starts flashing. Once the desired time is flashing, wait 4 seconds and that time will be accepted by the control. (Figure 3)

Depress and repeat until desired time starts flashing.

Figure 3

3. Changing Session Temperature. After the time has been selected, the red 100 ° LED will automatically start flashing. If this is the desired temperature, wait 4 seconds and that temperature will be accepted by the control and the generator will start. If a different temperature is desired, momentarily press the “Control Button”. Repeat until the red LED associated with your desired temperature starts flashing. Once the desired temperature is flashing, wait 4 seconds and that temperature will be accepted by the control and the generator will start. (Figure

Depress and repeat until desired temperature starts

4.

DOC NO. 81157

Figure 4

12 OF 14 Rev N/C 03-09 SAS

4. Manual Power Off. To manually power off the generator before the selected time has expired, press the “Control Button” once. The LED’s will go off and the generator will turn off.

(Figure 5)

Note: The TT control has a built in memory and will remember your time and temperature setting for the next session.

Depress once to turn off generator

Before timer expires.

Figure 5

5. Diagnostic Feature. The TT control has a unique diagnostic feature. If there is a malfunction within the unit, it will alert you. The red 115 ° LED will flash when the low water sensor is activated, the red 110 ° LED will flash if the shower area exceeds 135°F, and the red100° LED will flash if the control button becomes stuck. If any of these diagnostics happen the unit will shut down and lock out all user interfaces. To reset the unit, power will need to be reset at the breaker. Contact a Steam Services technician at (800) 776-0711 for further trouble shooting steps. (Figure 7)

Low Water Indication

Over Temperature Indication

Stuck Button

Indication

Figure 7

DOC NO. 81157 13 OF 14 Rev N/C 03-09 SAS

BY THERMASOL

SSB-XX/LS HAS A 5 YEAR THERMASOL “NO QUESTIONS ASKED” – FACTORY WARRANTY

THERMASOL will repair the specific failure on your THERMASOL generator manufactured after March 1, 2009, at its factory for 5 years. All expenses required to remove and send the unit to the factory, return and reinstall the unit is the responsibility of the owner.

SSP-XX/ASD 1 YEAR IN HOME /6-YEAR AT FACTORY PARTS & LABOR WARRANTY

THERMASOL will warranty all parts found to have a manufacturing defect on your THERMASOL generator manufactured after March 1, 2009 and labor required to replace those parts for a period of 1-year on THERMASOL generators at your home. At the end of your 1-year in-home warranty, there will still be a 5 year THERMASOL “no questions asked” – factory warranty. THERMASOL will repair the specific failure on your THERMASOL generator manufactured after March 1, 2009, at its factory for 6 full years. All expenses required to remove and send the unit to the factory, return and reinstall the unit is the responsibility of the owner.

WARRANTY EXCLUSIONS

Any discoloration of the steam head and control due to staining, scratching or use of harsh or abrasive cleaning chemicals; calcification build-up due to water conditions and/or improper maintenance; damage caused in the event of accident, neglect, misuse, vandalism, fire, lightning, power surge, earthquake, flood or any other peril or damage to structure or other acts of God.

TERMINATION

This warranty will be terminated by THERMASOL for the following reasons: Improper installation or use; installations not observing National/Local Plumbing and/or Electrical codes; residential unit used in a non-residential or commercial application; service to equipment by unauthorized personnel; installation that does not permit proper access for service; nonpayment of repairs not covered under warranty; modification to any part of the unit; use of NON-THERMASOL repair parts.

LIABILITY EXCLUSIONS

1. THERMASOL will not be liable in any way for any contingent liability or incidental or consequential damages resulting from the sale, delivery, installation or use of its products. Users are responsible for suitability of the products for their application. Damage resulting from improper specification or application or other operating conditions beyond THERMASOL control is not under warranty.

2. THERMASOL will exercise reasonable efforts in rendering service under this warranty, but shall not be liable for any damage arising out of delays; this warranty only covers the repair and/or replacement of THERMASOL product as specified by the warranty.

3. This warranty gives you specific legal rights and you may also have other rights, which may vary, from state to state. Determination of rights under this warranty is in accordance with the laws of California. Any dispute under the warranty must be submitted and resolved by arbitration in California.

4. THERMASOL does not guarantee that a local service person will be available for in-home service. Unit may have to be removed and reinstalled at owner’s expense. It is the responsibility of the buyer to file a claim with the carrier/carriers for any product that has shipping damage to or from THERMASOL. An EVA (Evaluation Number) must be obtained from the factory and used on any correspondence or packages sent to the factory.

THERMASOL – Technical Support (800-776-0711),

(Monday – Thursday, 7:00 a.m. to 5:00 p.m. PST; Friday, 8:00 a.m. – 12:00 p.m. PST)

2255 Union Place, Simi Valley, Ca., 93065

STEAM SUITE - WARRANTY REGISTRATION CARD

OWNERS NAME:___________________________PHONE: (_____) _______________ E-MAIL:____________________

ADDRESS:_____________________________CITY:_____________________STATE:__________ZIP:______________

SERIAL NO: ___________________________ DATE CODE:________________ MODEL NO: _____________________

DATE OF PURCHASE:______________________________ DEALER/OUTLET: ________________________________

INSTALLER NAME: ____________________________ INSTALLER PHONE: (______)___________________________

INSTALLER ADDRESS:__________________________CITY: _____________________STATE: _____ZIP: __________

SIGNATURE: _________________________________________DATE INSTALLED:_____________________________

DOC NO. 81157 14 OF 14 Rev N/C 03-09 SAS