R8-DCM16A NPN TRANSISTOR OUTPUT MODULE BEFORE USE .... INSTRUCTION MANUAL

R8-DCM16A NPN TRANSISTOR OUTPUT MODULE BEFORE USE .... INSTRUCTION MANUAL
R8-DCM16A
INSTRUCTION MANUAL
NPN TRANSISTOR OUTPUT MODULE
(with short circuit protection; 16 points)
BEFORE USE ....
Thank you for choosing M-System. Before use, check the
contents of the package you received as below.
If you have any problems or questions with the product,
please contact M-System’s Sales Office or representatives.
■ PACKAGE INCLUDES:
NPN transistor output module.................................... (1)
■ MODEL NO.
Confirm that the model number described on the product is
exactly what you ordered.
■ INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
MODEL R8-DCM16A
■ EXCITATION SUPPLY
• Output terminal: Rated curent 3 A DC (rated current 3 A
for internal fuse (slow blow fuse i2t (A2sec) max. 5.04)
■ AND ....
•The unit is designed to function as soon as power is supplied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
INSTALLATION
■ HOW TO MOUNT THE MODULE ON DIN RAIL
• I/O Module
A
POINTS OF CAUTION
■ CONFORMITY WITH EC DIRECTIVES
•The equipment must be mounted inside a panel.
•The actual installation environments such as panel configurations, connected devices and connected wires may
affect the protection level of this unit when it is integrated
in a panel system. The user may have to review the CE
requirements in regard to the whole system and employ
additional protective measures to ensure CE conformity.
B
Confirm that the locking clamps of the I/O module are set.
Insert the module in parallel to the next one while aligning the grooves of
both modules (A & B in the above figure).
Maintain it perpendicularly to the rail.
■ GENERAL PRECAUTIONS
•Before you remove or mount the unit, turn off the power
supply and output signal for safety.
• Switches on the side of the module can be set for maintenance only while the power supply is off. Do not access
them while the power is supplied.
■ ENVIRONMENT
•Indoor use
•When heavy dust or metal particles are present in the air,
install the unit inside proper housing with sufficient ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not apply physical impact to the unit.
• Environmental temperature must be within -10 to +55°C
(14 to 131°F) with relative humidity within 30 to 90% RH
in order to ensure adequate life span and operation.
More I/O modules can be added in the same manner.
■ WIRING
•Do not install cables (power supply, input and output)
close to noise sources (relay drive cable, high frequency
line, etc.).
•Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: [email protected]
EM-9719
P. 1 / 4
R8-DCM16A
• Protective Cover
Groove
■ HOW TO UNMOUNT THE MODULE FROM DIN RAIL
Release the locking clamps and pull out straight the module.
Hook
The protective cover is to be attached over the connected I/O module
at the right end.
Align the hooks on the cover with the grooves of the module and slide it
straight until the hooks are latched.
• Removing an intermediate module
When removing the cover, pull it out while squeezing the hooks inward.
Caution !
1) Be careful not to hurt your hand by pointed edges of the internal
communication bus connector.
2) I/O modules cannot hold tightly on the DIN rail by themselves without
power/network module.
Secure them to the position if necessary by using DIN rail end plates.
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: [email protected]
EM-9719
P. 2 / 4
R8-DCM16A
COMPONENT IDENTIFICATION
FRONT VIEW
SIDE VIEW
Module Address Setting
Rotary SW
Status Indicator LED
456
78
78
456
x1
CARD ADD.
23
456
SW2
456
x10
78
23
78
23
Discrete Output Indicator LED
901
23
9
10
11
12
13
14
15
16
901
1
2
3
4
5
6
7
8
901
901
SW1
RUN
Function Setting
DIP SW
Internal Bus Connector
Output Connectors
On
SW4
12345678
On
Term
SW3
Terminator DIP SW
■ MODULE ADDRESS
The left switch determines the tenth place digit, while the
right switch does the ones place digit of the address.
Address is selected between 0 to 31.
(Factory setting: 0)
901
7 8
7 8
901
23
Output
Status
FUNCTION
Stopping
Valid host communication
Reading/writing configuration
Setting error
Parameter error
OFF
ON
23
OPERATION
OFF
Green ON
Green Blinking
Red ON
Red Blinking
OFF
Green ON
456
LED
Status
456
■ INDICATOR LED
Module Address Setting (x1)
Module Address Setting (x10)
■ OUTPUT CONNECTOR ASSIGNMENT
1
19
2
20
PIN
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17, 18
19, 20
ID
FUNCTION
Do1
Do2
Do3
Do4
Do5
Do6
Do7
Do8
Do9
Do10
Do11
Do12
Do13
Do14
Do15
Do16
0V
24V
Output 1
Output 2
Output 3
Output 4
Output 5
Output 6
Output 7
Output 8
Output 9
Output 10
Output 11
Output 12
Output 13
Output 14
Output 15
Output 16
Excitation supply 0V
Excitation supply 24V
■ OPERATING MODE
*Factory setting
• Output at The Loss of Communication
OUTPUT AT THE LOSS OF COMMUNICATION
Output Hold (*)
(last data correctly rerceived is hold)
Stop output (Output fixed at OFF)
SW4-5
OFF
ON
• Configuration Mode
CONFIGURATION MODE
DIP switch setting (*)
PC Configurator and communicaton
SW4-8
OFF
ON
• Terminator DIP SW
TERMINATOR SW
SW3
Without (*)
OFF
With
ON
Note: Be sure to set unused SW4-1 through 4-4, SW4-6, SW4-7
to OFF.
■ PC CONFIGURATOR
The following parameters can be set with using PC Configurator Software (model: R8CFG):
•Output at the startup
• Output at the loss of communication
• Common setting (loss of internal bus communication detection time)
Turn SW4-8 ON to allow programming by the PC Configurator via the Power/Network Module.
Refer to the users manual for the R8CFG for detailed operation of the software program.
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: [email protected]
EM-9719
P. 3 / 4
EXTERNAL DIMENSIONS
unit: mm (inch)
7 (.28)
R8-DCM16A
12 (.47) [3 (.12)]
[79 (3.11)]
[4 (.16)]
6 (.24)
55 (2.17)
7 (.28)
6 (.24)
115 (4.53)
DIN RAIL
(35 mm wide)
CONNECTION DIAGRAM
BUS CONNECTOR
EXC. SUPPLY
–
1 Do 1
INTERNAL BUS
INTERNAL POWER
WIRING INSTRUCTIONS
L
2 Do 2
L
3 Do 3
L
4 Do 4
L
5 Do 5
L
6 Do 6
L
7 Do 7
L
8 Do 8
L
9 Do 9
L
10 Do 10
L
11 Do 11
L
12 Do 12
L
13 Do 13
L
14 Do 14
L
15 Do 15
L
16 Do 16
L
+
■ MIL connector
PWB connector: M-System type
Recommended socket XG5N-201 (Omron)*1
Recommended contact XG5W-0231 (Omron)*1
Applicable wire size: AWG22, 17 strands, (0.16 dia)
*1. Not included in the package. Refer to the specifications of the product.
19 24V
20 24V
17 0V
18 0V
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: [email protected]
EM-9719