Cooper | DF6000 | Software Updates

Software Release For
DF6000/CF3000/FX6000
Site Installer Network Card
SOFTWARE UPDATES
DF6000/CF3000/FX6000 Software Updates
Latest Version:
Display 3.03.50 Loop: 3.2.4 (14)
Site Installer : 2.5.28
Network Card : 6.6
Engineering Change Note : 1163
Engineering Change Note : 1164
Engineering Change Note : 1165
Date: 15/10/10
DF6000/CF3000/FX6000 Analogue Addressable Panel
Important: These versions of Software loop and Display are compatible with previous versions
(See tables below).
Main features / Improvements
ü Better touch screen responsiveness.
ü Faster indication of fire/faults during printing mode
ü Added panel network filtering. (This feature will be explained in the latest release of Cooper fault
finding guide).
ü Enabling all will not fail if some outputs cannot be enabled, it will simply enable all that.
ü Accept commands from both HyperTerminal and PanelComm.
ü Network disabling of sounder 1 and sounder 2 removed in order to comply with the new EN54 pt2 1997+ A1:2006.
ü Added evacuate locking feature (this feature will be explained in the latest release of Cooper fault
finding guide).
ü Disabling a zone on a panel will disable that zone on all panels in the network.
ü Web server can get zone/address text information from the panel.
ü Australia Fire Brigade screen will now show address OR zone information depending on an option set
on 130170 menu(This feature will be explained in the latest release of Cooper fault finding guide).
ü Added loop repeater command either loop or network to mute the internal buzzer from the main
panel. (This feature will be explained in the latest release of Cooper fault finding guide).
ü Viewing of the status of T1/T2 timer. This feature will be explained in the latest release of Cooper
fault finding guide).
2
CF3000 / DF6000 / FX6000
SOFTWARE UPDATES
ü Indication of day/night mode on main display. This feature will be explained in the latest release of
Cooper fault finding guide).
ü Added new fan control features according to the new Australian standard AS1668. (This feature will
be explained in the latest release of Cooper fault finding guide)
ü Web server can request all disablement information for the panel over the network
ü Added a toggle on 130170 to enable/disable all outputs (panel + loop). (This feature will be explained
in the latest release of Cooper fault finding guide).
ü Added UL 864 Pt 9 requirements (feature available at access level 3).
ü Add German local requirement on FBF & FAT interfaces.
ü Site monitor can request various system data from panel (Web server feature).
ü Improved support for Non Fire input.
ü Updated Polish requirement. Polish font (codepage 1250).
• Extra characters on Polish keyboard
• Uploading log in Polish now has correct characters displayed on PC.
• Polish language now prints correctly.
• For Polish, technical input activation turns on an LED.
Bug Fixes
•
All panels now send at least one loop to Site Installer to get round a problem with how it stores zone
data.
•
Auxiliary board type is no longer reset on auto learn.
•
On download from PC to panel, the panel preserves settings not overwritten by the download.
•
When CDR data is reset (auto learn etc), FPE, FRE and sounder disablement flags are cleared.
•
Now shows correct count of zones in system details.
•
Filled in missing characters from central European font.
•
Corrected some problems with Czech and Slovak.
•
Fixed bug displaying fires and pre-alarms incorrectly on screen-cover level 1 screen.
•
For the central European font, the panel will now attempts to re-map the non displayable characters
when in text mode.
CF3000 / DF6000 / FX6000
3
SOFTWARE UPDATES
4
•
Font no longer reset after screen calibration.
•
Fixed bug on "go to" screen, if you did not select a loop it would not work, loop now defaults to 1.
•
Buzzer beeps only when user hits a control that does something, rather than when they touch the
screen.
•
Fixed bug where the level 1 "Accept fire" button was not working, it was going to another screen.
•
Fixed bug in sending pre-alarm across network, type was not being sent.
•
Fixed bug in detecting when a zone had become disabled by disabling all its devices.
•
Fixed bug in printing of panel disablements (FRE, FPE, sounders).
•
Fixed bug displaying panel number of the analogue value screen.
•
Fixed bug displaying the enable/disable status of sounders on the level 2 menu.
•
Analogue level test function importing wrong fault values for heat devices, causing heats to fault with
value <10.
•
Fixed a bug in the “Disable –All” menu 130170.
•
Fixed a problem with list of zones, if there is a gap, it does list all zones.
•
Fixed a problem with Australian FB screen as it would always initially show disabled address count as
0.
•
MCOM devices on loop4 activated by zones outside of populated list, sub address indexer not reinitialised for loop driver 2 downloadh
•
“Auto config” not locating ID mismatches.
CF3000 / DF6000 / FX6000
SOFTWARE UPDATES
Loop Software History Log
Date
15/08/10
15/09/09
15/08/08
20/07/07
Version
3.2.4.11
3.2.3.19
Comments
See above
Auto learn locking function
Supports Fan controls. Technical Input/Technical Output
Supports Non Fire Input
Added HMO (House of Multiple Occupancy) requirements as per BS5839 Pt6
Support New EN54 pt2 requirements. (Disable address moved to access level 3
and Disable LED now is off when delay are implemented)
Download analogue values and Event Log to PC.
T1/T2 can be Disable using panel clock or a loop addressable device.
AVF programmable 10 to 30s
AVF programmable by zone
Added Bell tone on Class Change
Pre-addressed Auto learn
Added German feature on FAT
Added Polish requirements
Approved to latest EN54 pt 2 :1997 +A1:2006 and EN54 pt 4: 1997
+A1:2002+A2:2006
3.2.01
3.0.0
Double Knock 2 devices within a Zone (addressable loop devices as well as panel
outputs), Calibration of Touch Screen: This feature has been removed from the
power up menu as well as during reset due to various complaints. Touch screen
calibration is only possible by either Panel com or activation of Class Change input
during Panel power up. Test Device on Output modules, Support Technical timers.
Increase the number of Devices alarm LED’s to 24, Support Russian, Afrikaans,
Vietnamese, Finnish, & Greek languages. Panel default to “Cooper Logo”, Disable
Buzzer at Access level 4 Support T1/T2 features (Swedish as well as Standard) ,
Call point override facility for T1/T2,T1/T2 override using programmable input on
site installer, Support Swedish Fire Brigade Interface with zone/address location
Printer monitoring (Paper and head up), Extended walk test (led remains on for 20
seconds), Added Australian tone on addressable sounders, Added overload Fault
on Loop when the load current is too high. (EN54 pt13 requirement) Added
"abnormal comms" Fault Condition, when the loop communication is (EN54 Pt13).
Support FAT interface (Fire Brigade interface on the network)Two network
protocols V1&V2 (V1 standard protocol, V2 standard+ FAT interface)Update
Display software using PC.“Display Program can be erased from panel via
HyperTerminal. Press Ctrl-X, then Y.Once erased, it can be programmed via
RS232 with "PanelProg".
Added above features as per ECN
Implemented Autolearn per loop, Integrations of Faults,
CF3000 / DF6000 / FX6000
5
SOFTWARE UPDATES
Loop Software History Log. Cont.
6
Date
16/03/07
Version
2.1.4
12/02/07
2.1.3
23/10/2006
22/09/2006
13/09/2006
2.1.2
2.1.1
2.0.15
10/08/2006
2.0.12
27/07/2006
2.0.10
26/05/2006
2.0.8
Comments
Update delete device, updated programmer, capacity 127 network panels. Alarm
verification on detectors
Italian mode overrides sounder programming, update on T1/T2. Evacuation with
no aux not setting the FRE Flag
Global output disabled for commissioning access level 4 fixed
Czech T1/T2 applied to panel outputs
Czech T1/T2 updated, now tests for day night mode, if night mode T1/T2 timers
are ignored.
Sounder disablements from aux boards-now disables only sounder outputs
FPE disablement, now disablement all panel outputs exclude sounders and panel
FRE
Australian no longer latches.
Read types from network fire command
Set up day/night mode
Australian mode now exist inside the UK version
SP40 Voice Evac interface now recognized.
Australian variant with key switch
T1/T2 implemented for Czech
CF3000 / DF6000 / FX6000
SOFTWARE UPDATES
Display Software History Log : (Micro Board)
Date
15/08/10
15/09/09
Version
3.3.50
3,03.19
15/08/08
3.02.03
Comments
See above
Auto learn locking function
Supports Fan controls ,Technical Input/Technical output
Supports Non Fire Input
Added HMO (House of Multiple Occupancy) requirements as per BS5839 Pt6
Support New EN54 pt2 requirements (Disable address moved to access level 3
and disable LED now is off when delay are implemented)
Download analogue values and Event Log to PC
T1/T2 can be Disable using panel clock or a loop addressable device
AVF programmable 10 to 30s
AVF programmable by zone
Added Bell tone on Class Change
Pre-addressed Auto learn
Added German feature on FAT
Added Polish requirements
Approved to latest EN54 pt 2 :1997 +A1:2006 and EN54 pt 4: 1997
+A1:2002+A2:2006
Calibration of touch screen: This feature has been removed from the power up
menu as well as during reset due to various complaints.
Touch screen calibration is only possible by either panel com or activation of class
Change input during panel power up.
Test device on output modules, support technical timers. Increase the number of
devices alarm LED’s to 24, support Russian, Afrikaans, Vietnamese, Finnish, &
Greek languages. Panel default to “Cooper Logo”, Disable Buzzer at Access level
4. Support T1/T2 features (Swedish as well as Standard ) ,Call point override
facility for T1/T2,T1/T2 override using programmable input on site installer, Support
Swedish Fire Brigade Interface with zone/address location. Printer monitoring
(Paper and head up), Extended walk test (led remains on for 20 seconds), Added
Australian tone on addressable sounders, Added overload Fault on Loop when the
load current is too high. (EN54 pt13 requirement). Added "abnormal comms" fault
condition, when the loop communication is (EN54 Pt13). Support FAT interface
(Fire Brigade interface on the network)Two network protocols V1&V2 (V1 standard
protocol, V2 standard+ FAT interface) update display software using PC.“Display
Program can be erased from panel via HyperTerminal. Press Ctrl-X, then Y. Once
erased, it can be programmed via RS232 with "PanelProg".
Added above features as ECN
CF3000 / DF6000 / FX6000
7
SOFTWARE UPDATES
Display Software History Log : (Micro Board). Cont.
8
Date
20/07/07
Version
3.0.0
22/11/06
13/09/2006
27/07/2006
2.4.9
2.4.8
2.4.5
26/05/2006
2.4.2
Comments
Implemented all the above functions
Auto learn per loop
Added Next/Previous buttons on the “Test” & “Analogue value “ screens
Facility to remove integration of Fault at access level 3 for speed of fault
findings/commissioning
If a sounder is added without PC programming, it will default to Global alarm
Facility to remove Call point ID Text a access level 3.This is mainly used if a call
point is used for other application.
Implemented Spanish/Latvian/Croatian languages
Updated Italian/Hungarian/Czech/Polish
Add Slovak & Slovenian language
Change maximum output per loop to 120
Send device text across network
Australian Fire Brigade
Australian brigade Screen reset is now global rather than local
Sounder Enable/Disable in German prints correctly
Analogue values in German prints correctly
When Fire Brigade screen appears backlight is always turned on
In the “Brigade colors ” release, the Fire Brigade has labels denoting the color of
various buttons and indications
When auto learn was done, the language was set back to English
CF3000 / DF6000 / FX6000
SOFTWARE UPDATES
DF6000/CF3000/FX6000 Site Installer
Latest Version:2.5.28.6
Engineering Change Note : 1164
These versions of Site Installer are compatible with previous versions.
Site Installer Features
ü Swedish, French, Dutch, Slovakian translations.
ü Retrieve event log and analogue values.
ü Screen grab, firmware upload, erase CDR, screen calibration.
ü New interface improvement for ease of use (i.e Text manager).
ü Add support for RF panel and RF devices.
ü
Integrated and improved logo upload.
ü Screen grab, firmware upload, erase CDR, screen calibration.
ü Support for configuring the mimic repeater and Fan control.
ü Support updating and programming of panel display software (No need for a programmer).
ü Improvements and additions to the sanity checking.
ü Added UL 864 9th edition requirements.
ü Added support for device 254 (Reserved address).
CF3000 / DF6000 / FX6000
9
SOFTWARE UPDATES
Site Installer History Log
10
Date
15/08/10
Version
2.5.28
2.5.22
15/09/09
2.4.18
Comments
See above features
Support Mimic Repeater
Support updating panel display software
Sanity Checks
Add French, Dutch and Swedish update
Panel Com Commands
Log retrieval and storage
Support for different editions of SI with varying panel support
Move to SQL Server Compact Edition (64bit support)
Calibrate screen/Panel Com part of Site installer
Retrieve event log and analogue values
Integrated fan controller
PAVA output
Integrated commission transfer solution
.Net resources for translations and right-to-left text support
Integrated and improved logo upload
CF3000 / DF6000 / FX6000
SOFTWARE UPDATES
DF6000/CF3000/FX6000 Network Card
Latest Version : 6.6
Engineering Change Note : 1165
These versions of network card are compatible with previous versions.
Features
ü The card now check for acknowledgment after sending a message to the panel before removing the
message from the buffer card.
ü Network monitoring will now start after power up without requiring a master panel soft reset.
ü Repeat timer value changed to 48ms.
Network History Log
Date
15/10/10
20/07/08
19/09/06
18/09/06
13/09/06
07/02/06
28/07/05
09/11/04
08/10/04
Version
6.6
5.0
4b
4a
4
3a
3
2
1
Comments
See above features
Recompiled for Rev. 2c pcb.
Minimum slave timeout set to 30s
If number of panels is < 50, slave timeout defaults to 300s
Slave timeout now scales with number of panels
Maximum number of panels increased to 128
Monitoring now activated only if number of panels > 1
Added ability to switch between master and slave modes
Monitoring now continues after a reset.
CF3000 / DF6000 / FX6000
11
Head Office
Sales
Tel:
Fax:
Email:
01302 303999
01302 303333
sales@cooperfire.com
Technical
Tel:
01302 303350
Fax:
01302 303332
Email: techsupport@cooperfire.com
Export
Tel:
01302 303334
Fax:
01302 303345
Email: export@cooperfire.com
Service
Tel:
01302 303352
Fax:
01302 303332
Email: service@cooperfire.com
Web:
www.cooperfire.com
Head Office
Cooper Lighting and Safety Ltd
Wheatley Hall Road
Doncaster
South Yorkshire
DN2 4NB
CC1838
Download PDF