PHS-P3, Accessories for Valve/Actuator Area

PHS-P3, Accessories for Valve/Actuator Area
Data sheet
Sheet No.: PHSP3.01 RevA
Date: October 2010
PHS P3
PHS-P3, Accessories for Valve/Actuator Area
Application:
Description:
PHS Pipe Block: For emergency
operation of 1-line actuators (spring
return) by means of portable hand pump.
The block is pipe mounted.
PHS Pipe Block:
Block with single quick connection and stop valve. The block has connection tread G 3/8.
PHS Pipe Block:
Block with single quick connection and stop valve. The block has connection tread G1/4.
P3: Cross-over plate:
Plate for cross - connecting ports P and A, respectively B and T of a Cetop-3/NG 6 stack.
P3: Cross-over plate: Whenever a Cetop
-3/NG 6 mounting block is used for
mounting of control equipment on the
actuator, a P3 plate is necessary to close
the Cetop-3 “sandwich”.
PHS – bleeder fail close:
Bleed pipe from actuator can be connected to block.
PHS – bleeder fail open, submerged:
Bleed pipe from actuator can be connected to block.
DPHS – pipe block, submerged:
For emergency operation of 2-line actuator by means of portable hand pump. The block
is pipe mounted.
Main data:
PHS – bleeder fail close: For emergency
operation of 1-line submerged actuator
(fail close) by means of portable hand
pump. The block is pipe mounted.
PHS – bleeder fail open: For emergency
operation of 1-line submerged actuator
(fail open) by means of portable hand
pump. The block is pipe mounted.
PHS
P3
PHS-bleed
fail close
Max. operation pressure:
135 bar/2000 PSI
Max test pressure:
225 bar/3250 PSI
DPHS
Flow rate at 100 bar,
(50 cSt visc.) l/min.
6
20
6
6
6
Weight approx.: kg/lb
0.6/1.3
0.2/0.4
1.1/2.4
1.1/2.4
1.1/2.4
Materials:
Brass
Application examples:
Remote breathing from actuator spring cavity.
Emergency operation by means
of portable hand pump.
DPHS – pipe block: For emergency
operation of 2-line actuator or system
consisting LPU, both S and D, by means
of portable hand pump.
www.Bettis.com
PHS-bleed
fail open
Copyright © Emerson Process Management. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.bettis.com or from your nearest Valve Automation Center.
USA: +1 281 727 5300 Europe: +31 74 256 1010 Asia-Pacific: +65 6501 4600
Data sheet
Sheet No.: PHSP3.02 RevA
Date: October 2010
PHS P3
Hydraulic diagram:
PHS Block
PHS block with bleeder for fail close
PHS block with bleeder for fail open
www.Bettis.com
Copyright © Emerson Process Management. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.bettis.com or from your nearest Valve Automation Center.
USA: +1 281 727 5300 Europe: +31 74 256 1010 Asia-Pacific: +65 6501 4600
Data sheet
Sheet No.: PHSP3.03 RevA
Date: October 2010
PHS P3
Main dimensions:
PHS Pipe Block G3/8”
(2.91)
43 (1.69)
6
(.24)
PHS Pibe Block G1/4”
14.5
(.57)
49 (1.93)
30 (1.18)
(7.87)
(.22)
(.22)
(.52)
(1.42)
(2.19)
18
(.52)
12
(.47)
(2.40)
11
(.43)
(.78)
69
(2.72)
(1.57)
33
(1.30)
(1.57)
(1.36)
5
(.20)
20
(.79)
13
(.51)
24 (.94)
38 (1.50)
38 (1.50)
11
(.43)
60 (2.36)
www.Bettis.com
40 (1.57)
71.5 (2.81)
14
(.55)
7.5
(.30)
30 (1.18)
60 (2.36)
26
(.98)
41.5 (1.63)
DPHS Block
11
(.43)
38 (1.50)
49 (1.93)
16
(.63)
40 (1.57)
Copyright © Emerson Process Management. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.bettis.com or from your nearest Valve Automation Center.
USA: +1 281 727 5300 Europe: +31 74 256 1010 Asia-Pacific: +65 6501 4600
Data sheet
Sheet No.: PHSP3.04 RevA
Date: October 2010
PHS P3
Main dimensions (continued):
PHS Bleeder Fail Open
P3
41.5 (1.63)
7.5
(.30)
(2.36)
60 (2.36)
(.39) (.28)
26
(.98)
14
(.55)
40 (1.57)
71.5 (2.81)
(1.77)
30 (1.18)
27 (1.06)
16
(.63)
40 (1.57)
40 (1.57)
14
(.55)
71.5 (2.81)
30 (1.18)
14
(.55)
7.5
(.30)
M8 x 12/16
26
(.98)
41.5 (1.63)
PHS Bleeder Fail Closed
60 (2.36)
11
(.43)
38 (1.50)
11
38 (1.50)(.43)
49 (1.93)
16
(.63)
40 (1.57)
Note: Not Certified dimensional drawings. Such drawings are available on request. Contact factory with correct model designation and serial number.
Important: Due to Emerson’s continuing commitment to engineered product advancement, data presented herin is subject to change.
The contents of the publication are presented for information purposes only, and while effort has been made to ensure their accuracy,
they are not to be construed as warranties or guarantees, expresses or implied, regarding the products or services described herein or their use or applicability.
All sales are governed by our terms and conditions, which are available on request.
We reserve the right to modify or improve the designs or specifications of our products at any time without notice.
www.Bettis.com
Copyright © Emerson Process Management. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.bettis.com or from your nearest Valve Automation Center.
USA: +1 281 727 5300 Europe: +31 74 256 1010 Asia-Pacific: +65 6501 4600
(1.28)
(.28)
(1.59)
(1.22)
38 (1.50)
11
(.43)
49 (1.93)