World Marketing of America GSD3033 Stove Owner Manual

Add to my manuals
23 Pages

advertisement

World Marketing of America GSD3033 Stove Owner Manual | Manualzz

VENT-FREE GAS STOVE

MODEL: GSD3033

®

WARNING: This appliance is equipped for (Natural and Propane) gas. Field conversion is not permitted other than between natural or propane gases.

CAUTION – FOR YOUR SAFETY

WARNING: IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED

EXACTLY, A FIRE MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL

INJURY, OR LOSS OF LIFE.

Do not store or use gasoline or other flammable vapors and liquids in vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

·

Do not try to light any appliance.

·

Do not touch any electrical switch; do not use any phone in your building.

·

Immediately call your gas supplier from a neighbor’s phone. Follow the gas

supplier’s instructions.

·

If you cannot reach your gas supplier, call the fire department.

– Installation and service must be performed by a qualified installer, service agency or the gas supplier.

This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be provided.

Refer to Air For Combustion and Ventilation section on page 6 of this manual.

INSTALLER: DO NO DISCARD THIS MANUAL – LEAVE FOR HOMEOWNER’S FUTURE

REFERENCE

This appliance may be installed in an aftermarket*, permanently located manufactured (mobile) home, where not prohibited by local codes. This appliance is for use with the type of gas indicated on the rating plate only. This appliance is not convertible for use with other gases.

Questions about installation, operation, or troubleshooting? Before returning to your retailer, call KOZY

WORLD PHONE NUMBER (814)643-1775

WM-QD250T-0803

TABLE OF CONTENTS

Important Safety Information ....................................................................................................................................... 3

Air for Combustion and Ventilation............................................................................................................................. 6

Installation ..................................................................................................................................................................... 8

Operation...................................................................................................................................................................... 15

Cleaning & Maintenance ............................................................................................................................................ 18

Troubleshooting ......................................................................................................................................................... 19

Replacement Parts………………………………………………………………………………………………………………21

WARNING: READ THE INSTALLATION & OPERATION INSTRUCTIONS

BEFORE USING THIS APPLIANCE

IMPORTANT: Read instructions and warnings carefully before starting installation. Failure to follow

these instructions may result in a possible fire hazard and will void the warranty.

PRODUCT SPECIFICATIONS

ITEM NO. GSD3033

Input Rating 25000 BTU/Hr 25000 BTU/Hr

Natural

Piezo /Automatic

4 in. W.C.

LP/Propane

Piezo /Automatic

9 in. W.C.

Gas Type

Ignition

Manifold Pressure

Inlet Gas Pressure *For purposes of input adjustment

Maximum

Minimum *

Dimensions, inches( H x W x D )

Heater

Carton

Weight, lbs

Stove

Shipping

2

10.5 in.

5 in.

14 in.

11 in.

25 4/5 in.×32 1/4 in.×13 in.

25 1/5 in.×34 1/4 in.×13 in.

56.5

67.5

IMPORTANT SAFETY INFORMATION

IMPORTANT:

Read this owner’s manual carefully and completely before trying to assemble, operate, or service this heater. Improper use of this heater can cause serious injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning.

Only a qualified installer, service agent, or local gas supplier may install and service this product.

Installation and service must be performed by a qualified installer, service agency, or local gas supplier.

WARNING : Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.

WARNING: This appliance is equipped for Natural and Propane gas. Field conversion is not permitted other than between natural or propane gases.

CARBON MONOXIDE POISONING: Early signs of carbon monoxide poisoning resemble the flu with headaches, dizziness, or nausea. If you have these signs, the heater may not be working properly. Get fresh air immediately! Have heater serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart, or lung disease, anemia, those under the influence of alcohol, and those living in high altitudes.

NATURAL AND PROPANE/LP GAS: Natural and Propane/LP gases are odorless. An odor-making agent is added to the gas. The odor helps you detect a gas leak. However, the odor added to the gas can fade. Gas may be present even though no odor exists. Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this heater.

WARNING: Any change to this fireplace or its controls can be dangerous.

WARNING: Do not allow fans to blow directly into the heater. Avoid any drafts that alter burner flame patterns including ceiling fans. Altered burner patterns can cause sooting.

Do not use a blower insert, heat exchanger insert, or other accessory not approved for use with this heater.

Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.

Do not place clothing or other flammable material on or near the appliance. Never place any objects in the fireplace. Heater becomes very hot when running fireplace. Keep children and adults away from hot surfaces to avoid burns or clothing ignition. Fireplace will remain hot for a time after shutdown. Allow surfaces to cool before touching. Carefully supervise young children when they are in the room with fireplace.

You must operate this heater with the heater screen in place.

Keep the appliance area clear and free from combustible materials, gasoline, and other flammable vapors and liquids.

3

IMPORTANT SAFETY INFORMATION (CONTINUED)

This appliance is for use with only the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

1. Do not place Propane/LP supply tank(s) inside any structure. Store Propane/LP supply tank(s) outdoors.

2.

3.

This heater should not be installed in a bedroom or bathroom.

Do not use this heater as a wood-burning heater. Use only the logs provided with the heater.

4. Do not add extra logs or ornaments such as pine cones, vermiculite, or rock wool. Using these added items can cause sooting. Do not add lava rock around base. Rock and debris could fall into the control area of heater. After servicing, always replace screen before operating heater.

5. Make sure the heater screen is in place before running the heater.

6. This heater is designed to be smokeless. If logs ever appear to smoke, turn off heater and call a qualified service person. Note: During initial operation, slight smoking could occur due to log curing and the heater burning manufacturing residues.

7. To prevent the creation of soot, follow the instructions in Cleaning and Maintenance (page 18).

8. Before using furniture polish, wax, carpet cleaner, or similar products, turn heater off. If heated, the vapors from these products may create a white powder residue within burner box or on

9. adjacent walls or furniture.

This heater needs fresh air ventilation to run properly. This heater has an Oxygen Depletion

Sensing (ODS) safety shutoff system. The ODS shuts down the heater if not enough fresh air is available. See Air for Combustion and Ventilation, pages 6 through 8. If heater keeps shutting off, see Troubleshooting, pages 19 through 21.

10. Do not run heater:

Where flammable liquids or vapors are used or stored.

Under dusty conditions.

11. Do not use this heater to cook food or burn paper or other objects.

12. Do not use this heater if any part has been under water. Immediately call a qualified service technician to inspect the heater, and to replace any part of the control system and any gas control which has been under water .

13. Turnoff and unplug heater and let cool before servicing. Only a qualified service person should service and repair heater.

14. Operating heater above elevations of 4,500 feet could cause pilot outage.

15. Do not operate heater if any log is broken. Do not operate heater if any log is chipped (dime-sized or larger).

16. To prevent performance problems, do not use a propane/LP fuel tank of less than 100 lbs capacity.

4

QUALIFIED INSTALLING AGENCY

Installation and replacement of gas piping, gas utilization equipment or accessories and repair and servicing of equipment should be performed only by a qualified agency. The term “qualified agency” means any individual, firm, corporation, or company that either in person or through a representative is engaged in and is responsible for: a) The installation, testing, or replacements of gas piping or b) The connection, installation, testing, repair, or servicing of equipment; that is experienced in such work; that is familiar with all precautions required; and that has complied with all the requirements of the authority having jurisdiction.

PRODUCT FEATURES

SAFETY PILOT

This heater has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS/pilot shuts off the heater if there is not enough fresh air.

PIEZO IGNITION SYSTEM

This heater is equipped with an electronic piezo control system. This system requires AAA batteries (provided).

THERMOSTAT HEAT CONTROL

The control automatically cycles the burner on and off to maintain a desired room temperature. See page 15

DUAL FUEL CAPABLE

Your heater is equipped to operate on either Propane or Natural gas. The heater is shipped from the factory ready for connecting to Propane. The heater can easily be changed to Natural gas by having your qualified installer follow the instructions on page 12 & 13 and the markings on the heater.

State of Massachusetts: The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts. Sellers of unvented propane or natural gas-fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit.

In the State of Massachusetts, unvented propane or natural gas-fired space heaters shall be prohibited in bedrooms and bathrooms.

In the State of Massachusetts the gas cock must be a T-handle type. The State of Massachusetts requires that a flexible appliance connector cannot exceed three feet in length.

LOCAL CODES

Install and use heater with care. Follow all local codes. In the absence of local

Codes use the latest edition of the National Fuel Gas Code, ANSI Z223.1/ NFPA54.

*Available from:

American National Standards Institute, lnc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, lnc.

1Batterymarch Park

Quincy, MA 02269-9101

This heater is designed for vent-free operation. State and local codes in some areas prohibit the use of vent-free heaters.

5

UNPACKING

1. Remove top inner pack

2. Tilt carton so that fireplace is upright.

3. Remove protective side packaging.

4. Slide fireplace out of carton.

5. Remove protective plastic wrap.

6. Hold the screen lift and pull forward.

7. Remove log set by cutting plastic ties.

8. Carefully un-wrap log.

9. Check for any shipping damage. If stove or log is damaged, promptly inform your dealer where you bought the fireplace.

PRODUCT IDENTIFICATION

Figure 1

WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM HEATERS

Water vapor is a by-product of gas combustion. An unvented room heater produces approximately one (1) ounce (30ml) of water for every 1,000 BTUs (.3KWs) of gas input per hour.

An unvented room heater is recommended as a supplemental heater (one room) rather than a primary heat source (an entire house). In most supplemental heat applications, the water vapor does not create a problem. In most applications, the water vapor enhances the low humidity atmosphere experienced during cold weather. The following steps will help ensure that water vapor does not become a problem.

1. Be sure the heater is sized properly for the application, including adequate combustion air and circulation air.

2. If high humidity is experienced, a dehumidifier may be used to help lower the water vapor content of the air.

3. Do not use an unvented room heater as the primary heat source.

AIR FOR COMBUSTION AND VENTILATION

WARNING: This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air. Read the following instructions to insure proper fresh air for this and other fuel-burning appliances in your home:

Producing Adequate Ventilation

The following are excerpts from National Fuel Gas Code, NFPA 54/ANSI Z 223.1. Air for Combustion and Ventilation.

All spaces in homes fall into one of the three following ventilation classifications:

1. Unusually Tight Construction

2. Unconfined Space

3. Confined Space

The information on pages 6 through 8 will help you classify your space and provide adequate ventilation.

Confined and Unconfined Space

The National Fuel Gas Code, ANSI Z223.1 defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 BTU per hour (4.8 cubic meter per kilowatt) of the aggregate input rating of all appliances installed in that space and an unconfining space as a space whose volume is not less than 50 cubic feet per 1,000 BTU per hour (4.8 cubic meter per kilowatt) of the aggregate input rating of all appliances installed in that space. Rooms connected directly with the space in which the appliances are installed*, through openings not furnished with doors, are considered a part of the unconfined space.

This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation.

* Adjoining rooms are connecting only if there are doorless passageways or ventilation grills between them.

Unusually Tight Construction

The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation.

However, in buildings of unusually tight construction, you must provide additional fresh air.

6

Unusually tight construction is defined as construction where: a) Walls and ceilings exposed to the outside atmosphere have a continuous water vapor retarder with a rating of one perm ( 6x10-11kg per pa-sec-m 2 ) or less with openings gasketed or sealed and b) Weather stripping has been added on windows that can be opened and doors and c) Caulking or sealants are applied to areas such as joints around window and door frames, between sole plates and floors, between wall-ceiling joints, between wall panels, at penetrations for plumbing, electrical, and gas lines, and at other openings.

If your home meets all of the three criteria above, you must provide additional fresh air. See Ventilation Air From

Outdoors (page 8). If your home does not meet all of the three criteria above, proceed to "Determining Fresh-Air Flow

For Heater Location" (below).

DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION

Determining if You Have a Confined or Unconfined Space

Use this worksheet to determine if you have a confined or unconfined space.

Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms.

1. Determine the volume of the space Length × Width × Height= cu. ft. (volume of space)

Example: Space size 20ft. (length) × 16ft. (width) × 8ft. (ceiling height) = 2560cu. ft. (volume of space) If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of the space.

2. Divide the space volume by 50 cubic feet to determine the maximum BTU/hr the space can support.

(volume of space) ÷ 50 cu. ft. = (Maximum Btu/Hr the space can support)

Example: 2560 cu. ft. (volume of space) ÷ 50 cu. ft. = 51.2 or 51,200 ( maximum BTU/hr the space can support ).

3. Add the BTU/hr of all fuel burning appliances in the space.

Vent-free heater

Gas water heater*

Gas furnace

Vented gas heater

Gas heater logs

Other gas appliances* +

BTU/hr

BTU/hr

BTU/hr Example:

BTU/hr Gas water heater 30,000 BTU/hr

BTU/hr Vent-free heater + 26,000 BTU/hr

*Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the outdoors.

4. Compare the maximum BTU/hr the space can support with the actual amount of BTU/hr used.

BTU/hr (maximum the space can support)

BTU/hr (actual amount of Btu/Hr used)

Example: 51,200 BTU/hr (maximum the space can support)

56,000 BTU/hr (actual amount of Btu/Hr used)

The space in the above example is a confined space because the actual BTU/hr used is more than the maximum BTU/hr the space can support. You must provide additional fresh air. Your options are as follows: a) Rework worksheet, adding the space of an adjoining room. If the extra space provides an unconfined space, remove door to adjoining room or add ventilation grills between rooms. See “Ventilation Air from

Outdoors,” page 8. b) Vent room directly to the outdoors. See “Ventilation Air from Outdoors,” page 8. c) Install a lower BTU/hr heater, if lower BTU/hr size makes room unconfined. If the actual BTU/hr used is less than the maximum BTU/hr the space can support, the space is an unconfined space. You will need no additional fresh air ventilation.

WARNING: If the area in which the heater may be operated is smaller than that defined as an unconfined

Space or if the building is of unusually tight construction, provide adequate combustion and ventilation air by one of the methods described in the National Fuel Gas Code, ANSI Z223.1/ NFPA, air for combustion and

ventilation or applicable local codes.

7

Ventilation Air From Inside Building

This fresh air would come from adjoining unconfined space.

When ventilating to an adjoining unconfined space, you must provide two permanent openings: one within 12 inches of the wall connecting the two spaces (see options 1 and 2,

Figure 2). You can also remove door into adjoining room

(see option 3, Figure 2). Follow the National Fuel Gas Code

NFPA 54/ANSI Z223.1. Section 5.3, Air for Combustion and

Ventilation for required size of ventilation grills or ducts.

Ventilation Air From Outdoors

Provide extra fresh air by using ventilation grills or duct. You must provide two permanent openings: one within 12 inches of the ceiling and one within 12 inches of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces.

Follow the National Fuel Gas Code NFPA 54/ANSI Z223.1,

Section 5.3. Air for Combustion and Ventilation for required size of ventilation grills or ducts.

IMPORTANT: Do not provide openings for inlet or outlet air into attic if attic has a thermostatcontrolled power vent. Heated air entering the attic will activate the power vent. Rework worksheet, adding the space of the adjoining unconfined space.

The combined spaces must have enough fresh air to supply all appliances in both spaces.

INSTALLATION

Figure 2 -Ventilation Air from Inside Building

Figure3 -Ventilation Air from Outdoors

NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your primary heating system. Do not install this heater as your primary heat source. If you have a central heating system, you may run your system's circulating blower while using heater. This will help circulate the heat throughout the house.

WARNING: A qualified technician person must install heater. Follow all local codes.

WARNING: Never install the heater

· In a bedroom or bathroom

· In a recreational vehicle

· Where curtains, furniture, clothing, or other flammable objects are less than 42 inches from the front, top or sides of the heater.

· In high traffic areas

· In wind or drafty areas

CAUTION : This heater creates warm air currents. These currents move heat to wall surfaces next to heater. Installing heater next to vinyl or cloth wall coverings or operating heater where impurities (such as tobacco smoke, aromatic candles, cleaning fluids, oil or kerosene lamps, etc.) in the air exist may discolor walls.

WARNING : Maintain the minimum clearances. If you can, provide greater clearances from floor, ceiling, and adjoining side and back walls.

8

INSTALLATION

IMPORTANT: Vent-free heaters add moisture to the air. Although this is beneficial, installing heater in rooms without enough ventilation air may cause mildew to form from too much moisture. See Air for Combustion and

Ventilation, pages 6 through 7.

CHECK GAS TYPE

Use only the type of gas indicated on the plate. If your gas supply can not meet that requirement, do not install heater.

CLEARANCES TO COMBUSTIBLES

Carefully follow the instructions below. This fireplace is a freestanding unit designed to set directly on the floor or on a mantel base.

IMPORTANT: You must maintain minimum wall and ceiling

clearances during installation. The minimum clearances

are shown in Figure 4. Measure from outermost point of fireplace.

Minimum Wall and Ceiling Clearances (see Figure 4)

A. Clearances from outermost point of fireplace to any combustible side wall should not be less than 12 inches.

B. Clearances from the fireplace to the ceiling should not

be less than 48 inches.

.

Figure 4 – Minimum Clearance to Wall and Ceiling

CONNECTING TO GAS SUPPLY

WARNING: A qualified technician must connect heater to gas supply. Follow all local codes.

CAUTION : Never connect heater directly to the gas supply. This heater requires an external regulator (not supplied). The external regulator between the gas supply and heater must be installed.

INSTALLATION ITEMS NEEDED

Before installing heater, make sure you have the items listed below:

· piping (check local codes)

· sealant (resistant to propane/LP gas)

· equipment shutoff valve*

· test gauge connection**

· sediment trap

· tee joint

· pipe wrench

· flexible gas (check local code)

* A CSA design-certified equipment shutoff valve with 1/8-inch NPT tap is an acceptable alternative to test gauge connection. Purchase the optional CSA design-certified equipment shutoff valve from your dealer.

WARNING: Never connect heater to private (non-utility) gas wells. This gas is commonly known as wellhead gas.

9

The installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water column for propane and between 5 and 10.5 inches of water column for natural gas. If you do not reduce incoming gas pressure, heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 5. Pointing the vent down protects it from freezing rain or sleet (see Figure 6).

Figure 5 - Gas Regulator Location and

Gas Line Access Into Stove Cabinet

10

Figure 6 - External Regulator With Vent

Pointing Down

CAUTION: Use new black iron or steel pipe only. Internally tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2 inch diameter or greater to allow proper volume gas to heater.

If pipe is too small, loss of pressure will occur. Installation must include an equipment shutoff valve, union, and plugged 1/8-inch NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 7).

IMPORTANT : Install equipment shutoff valve in an accessible location. The equipment shutoff valve is for turning on or shutting off the gas to the appliance. Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.

CAUTION: Use pipe joint sealant that is resistant to gas (PROPANE or NATURAL GAS).

We recommend that you install a sediment trap in a supply line as shown in Figure 7. Place sediment trap where it is within reach for cleaning. Install in the piping system between fuel supply and heater. Place sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants.

This keeps them from going into heater controls. If sediment trap is not installed or is installed incorrectly, heater may not run properly.

CAUTION: Avoid damage to regulator.

Hold gas regulator with wrench when connecting into gas piping and/or fittings.

Gas supplier provide external regulator

for natural gas.

Figure 7 -Gas Connection

*Purchase the optional CSA design-certified equipment

INSTALLATION

Continued

shut off valve from your dealer. See "Accessories".

** Minimum inlet pressure for purpose of input adjustment.

CAUTION: Two gas line installations at the same time is forbidden. Do not open cover while the heater is running.

Heater is pre-set at factory for propane gas no changes are required for connecting to propane.

Only a qualified installer or service technician can perform gas selection and connecting to gas supply.

For changing from propane to natural gas supply

1. Remove bottom screw from cover plate, see Figure 8, and rotate to expose gas selection valve.

2. For NATURAL GAS, press in knob using a flat screw driver with a blade the width of a quarter and turn

knob clockwise until the knob locks into the NG position (see Figure 9). Selection valve must be

locked into the NG position. Do not operate heater between locked positions!

3. Rotate and close cover over gas selection valve and reinstall screw.

4. Remove hex plug (with wrench provided) from natural gas inlet of regulator and install into LP inlet of regulator, use thread sealant to assure there are no leaks.

For changing from natural gas supply to propane supply

1. Remove bottom screw from cover plate, see figure 8, and rotate to expose gas selection valve.

2. For propane gas, press in knob using a flat screw driver with a blade the width of a quarter and turn knob counterclockwise until the knob locks into the LP position (see Figure 10). Selection valve must be locked into either the LP position or the NG position.

11

3. Rotate and close cover over gas selection valve and reinstall screw.

4. Remove hex plug from LP gas inlet of regulator and install into NG inlet of regulator, use thread sealant to

assure there are no leaks.

Figure-8

Figue-9

Figue-10

12

CHECKING GAS CONNECTIONS

WARNING : Test all gas piping and connections for leaks after

installing or servicing. Correct all leaks immediately.

Pressure Testing Gas Supply Piping System

Test Pressures In Excess Of 1/2 PSIG(3.5kPa)

1. Disconnect heater with its appliance main gas valve (control valve) and equipment shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig will damage heater regulator.

2. Cap off open end of gas pipe where equipment shutoff valve was connected.

3. Pressurize supply piping system by either using compressed air or

4. opening gas supply tank valve.

5. Check all joints of gas supply piping system. Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak.

6. Correct all leaks immediately.

Figure 11 – Equipment Shutoff Valve

7. Reconnect heater and equipment shutoff valve to gas supply. Check reconnected fittings for leaks.

WARNING: Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks immediately.

Pressure Testing Heater Gas Connections

1. Open equipment shutoff valve (see Figure 11).

2. Open gas supply tank valve.

3. Make sure control knob of heater is in the OFF position.

4. Check all joints from equipment shutoff valve to control valve (Figure 12). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak.

5. Light heater (see Operating, page 15).Check all other

internal joints for leaks.

6. Turn off heater (see To Turn Off Gas to Appliance, Page 16).

Figure 12- Checking Gas Joints

CAUTION: Make sure external regulator has been installed between gas supply and heater. See guidelines under "Connecting to Gas Supply" (page 9).

Test Pressures Equal To or Less Than

1/2 PSIG (3.5 kPa)

1. Close equipment shutoff valve (see Figure 11, page 12).

2. Pressure supply piping system by either using compressed air or opening gas supply tank valve.

3. Check all joints from gas meter to equipment shutoff valve (see Figure 12).

Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak.

4. Correct all leaks immediately.

13

INSTALLATION

WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts included may result in property damage or personal injury.

CAUTION : After installation, and periodically thereafter, check to ensure that no flame comes in contact with any log. With the heater set to High, check to see if flames contact any log. If so, reposition logs according to the log installation instructions in this manual.

Flames contacting logs will create soot.

Figure 14

1. All logs.

Figure 16

Figure 13 - Installing Log Set

IMPORTANT: Make sure log does not cover any burner ports (see Figure

13). It is very important to install the logs exactly as instructed. Do not modify logs. Use logs supplied with heater only.

Figure 15

STEP 2: Install log 2 onto the two slots in left plate.

Figure18

STEP 4: Insert the recessed holes on the bottom of log 4 onto the pins on log 1 and 2.

STEP 1: Install log 1 onto the two slots in middle plate.

Figure 17

STEP 3: Install log 3 onto the two slots in right plate.

Figure 19

14

STEP 5: Insert the recessed holes bottom of log

5 onto the pins on log 1 and 3.

OPERATION

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

NOTICE: During initial operation of new fireplace, burning logs will give off a paper-burning smell. Orange flame will also be present. Open a window to vent smell. This will last only few hours.

CAUTION: Do not try to adjust heating levels by using the equipment shutoff valve.

A. This appliance has a pilot which must be lighted by the electronic ignitor. When lighting the pilot, follow these instructions exactly.

B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.

• Do not touch any electrical switch; do not use any phone in your building.

• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

• If you cannot reach your gas supplier, call the fire department

C. Use only your hand to push control. Never use tools. If the appliance does not operate, don’t try to repair it. Call a qualified service technician or gas supplier. Forced or attempted repair may result in fire or explosion.

D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control, which has been under water.

Note: Please wait one minute after shutting off fireplace to allow the control valve to reset before starting again.

THERMOSTATIC CONTROL OPERATION

The thermostatic control used on this model differs from standard thermostats. Standard thermostats simply turn the burner on and off. The thermostat used on this heater senses the room temperature. At times the room may exceed the set temperature. If so, the burner will shut off. The burner will cycle back on when room temperature drops below the set temperature. The control knob can be set to any comfort level.

Note: The thermostat sensing bulb measures the temperature (depending on housing construction,

The thermostatic control used on this model differs from standard thermostats. Standard thermostats simply turn the burner on and off. The thermostat used on this heater senses the room temperature. At times the room may exceed the set temperature. If so, the burner will shut off. The burner will cycle back on when room temperature drops below the set temperature. The control knob can be set to any comfort level between HIGH (5) and LOW (1).

15

LIGHTING INSTRUCTIONS

1. STOP! Read the safety information on page 3.

2. Warning: You must operate this fireplace with the fireplace screen in place. Make sure fireplace screen is installed before running fireplace.

3. Turn control knob clockwise to the OFF position, see Figure 20.

4. Wait five (5) minutes to clear out any gas. Then smell for gas around heater and near floor. If you smell gas, STOP! Follow "B" in the safety information on Warnings plate. If you don't smell gas, go to the next step.

5. Turn control knob counterclockwise to the PILOT position. Keep control knob pressed in for five (5) seconds. Note: You may be running this heater for the first time after hooking up to gas supply. If so , the control knob may need to be pressed in for 30 seconds. This will allow air to bleed from the gas system. If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs.

6. With control knob pressed in, push down and release ignitor button. This will light pilot. The pilot is attached to the rear of the front burner. If needed, keep pressing ignitor button until pilot lights. Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match.

7. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

Note: If pilot goes out, repeat steps 3 through 7. This heater has a safety interlock system. Wait one (1) minute before lighting pilot again.

8. Warning Make sure while the input gas type is NG, pilot burner NG ignites; while the input type is LP, pilot burner LP ignites. Note: If you find anything abnormal in this step, repeat steps 2 through 8.

9. Turn control knob counterclockwise to the desired heating level. The main burner should light. Set control knob to any heat level between HI and LO (5 –1).

TO TURN OFF GAS TO APPLIANCE

Shut off heater

Turn Control Knob clockwise to the OFF position.

Do not force.

Figure 20

MANUAL LIGHTING PROCEDURE

(Match light)

1. Remove screen by lifting and pulling forward.

2. Follow steps 1 through 5 under MANUAL OPERATING Lighting Instructions.

3. With Control Knob in PILOT position, strike match, and hold near pilot. Press in Control Knob; pilot should light.

4. Keep Control Knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release Control Knob.

5. Make sure the fireplace screen is in place before operating fireplace.

.

16

INSPECTING BURNERS

Check pilot flame pattern and burner flame patterns often.

PILOT FLAME PATTERN

1. Turn control knob to pilot position

2. Inspect pilot flame and refer to Figure 21 and 22.

· Figure 21shows a correct pilot flame pattern.

· Figure 22 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the heater will shut down.

· If the pilot flame is incorrect, as shown in Figure 22.

Turn heater off (see To Turn Off Gas to Appliance, page 16)

See troubleshooting, page 19.

Figure 21 -Correct Pilot Flame

Pattern

BURNER FLAME PATTERN

· Figure 23 shows a correct burner flame pattern.

· Figure 24shows an incorrect burner flame pattern.

If burner flame is incorrect:

Turn heater off (see To Turn Off Gas to Appliance, page 16)

see Troubleshooting, Page 19.

Figure 23- Correct Flame Pattern with Control Knob Set to High Flame (5)

Installation for Legs

Figure 22- Incorrect Pilot Flame

Pattern

Figure 24 -Incorrect Flame Pattern with

Control Knob Set to High (5)

Lay heater down on it’s back and attach legs with fasteners provided.

17

CLEANING AND MAINTENANCE

WARNING: Failure to keep primary air openings of burners clean may result in sooting and property damage.

CAUTION: You must keep control areas, burner, and circulating air passageways of heater clean.

Inspect these areas of heater before each use. Have heater inspected yearly by a qualified service person. Heater may need more frequent cleaning due to excessive lint from carpeting, bedding material, pet hair, etc.

CLEANING ODS/IGNITOR AND BURNER

Clean with a vacuum cleaner.

CLEANING BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE

We recommend that you clean the unit every three months or after 2500 hours of operation. We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recommend using compressed air no greater than 30 PSI. You can use a vacuum cleaner in the blow position. If using compressed air in a can, please follow the directions on the can. If you don't follow directions on the can, you could damage the pilot assembly.

1. Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes.

2. Inspect burner, pilot and primary air inlet holes on injector holder for dust and dirt (see Figure 25).

3. Blow air through the ports/slots and holes in the burner.

4. Check the injector holder located at the end of the burner tube again. Remove any large particles of dust, dirt, lint, or pet hair with a soft cloth or vacuum cleaner nozzle.

5. Blow air into the primary air holes on the injector holder.

6. In case any large clumps of dust have now been pushed into Figure 25 – Injector holder on the burner. Repeat steps 3 and 4. Clean the pilot assembly also. Outlet Burner Tube

A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly. There is a small pilot air inlet hole about two inches

Use a soft, clean cloth from where the pilot flame comes out of the pilot assembly inlet hole. You may blow through a drinking straw if compressed dampened with mild

(see Figure 26). With the unit off, lightly blow air through the air clean air inlet holes air is not available.

CABINET

• Air Passageways

• Use a vacuum cleaner or pressurized air to clean.

the cabinet to remove dust.

LOGS

• If you remove logs for cleaning, refer to Installing Logs (page 14)

for proper log placements. Figure 26 – Pilot Air Inlet Hole

• Replace logs if broken or chipped (dime-sized or larger).

MAIN BURNER

Periodically inspect all burner flame holes with the heater running. All slotted burner flame holes should be open with yellow flame present. All round burner flame holes should be open with a small blue flame

Present. Some burner flame holes may become blocked by debris or rust, with no flame present. If so, turn off heater and let cool, either remove blockage or replace burner. Blocked burner flame holes will create soot.

FAN (OPTIONAL PART)

Refer to model SSQEB100 manual.

18

TROUBLESHOOTING

NOTE: Turn the control knob to "off" position first and wait for one minute. Then turn the control knob to on position. Please wait for one minute to allow valve to reset.

WARNING: If you smell gas

Shut off gas supply.

•Do not try to light any appliance.

•Do not touch any electrical switch; do not use any phone in your building.

•Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

•If you cannot reach your gas supplier, call the fire department.

WARNING: Make sure that power is turned off before proceeding.

WARNING : Turn off and let cool before servicing. Only a qualified service person should service and repair fireplace.

CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/pilot unit.

OBSERVED PROBLEM POSSIBLE CAUSE REMEDY

When ignitor button is pressed in, there is no spark at ODS/pilot

1. Ignitor is positioned wrong.

2. Ignitor electrode is broken.

3. Ignitor electrode is not connected to ignitor cable.

4. Ignitor cable is pinched.

5. Damaged ignitor cable.

6. Bad piezo ignitor.

7. Low battery.

1.

2.

Replace ignitor.

Replace ignitor..

Reconnect ignitor cable. 3.

4. Free ignitor cable if pinched by any metal or tubing.

5. Replace ignitor cable.

6. Replace piezo ignitor.

7. Replace battery.

When ignitor button is pressed in, there is a spark at ODS/pilot but no pilot flame present.

1. Gas supply is turned off or equipment shutoff valve is closed.

2. Control knob not fully pressed in while pressing ignitor button.

3. Air in gas lines (new installation or recent gas interruption).

4. ODS/pilot is clogged.

5. Incorrect inlet gas pressure or inlet regulator is damaged.

6. Depleted gas supply

ODS/pilot lights but flame goes out when control knob is released.

1. Control knob is not fully pressed in.

2. Control knob is not pressed in long enough.

3. Equipment shutoff valve is not fully open.

4. Thermocouple connection is loose.

5. Thermocouple damaged

6. Control valve damaged.

.

19

1. Turn on gas supply or open equipment shutoff valve.

2. Fully press in control knob while pressing ignitor button.

3. Continue holding down control knob for 30 seconds to remove air. Repeat igniting operation until air is removed.

4. Clean ODS/pilot (see Cleaning

and Maintenance Page 18) or replace ODS/pilot assembly.

5. Check inlet gas pressure or replace inlet gas regulator.

6. Contact local propane/LP Gas

Company

1. Press in control knob fully.

2. After ODS/pilot lights, keep control knob pressed in 30 seconds.

3. Fully open equipment shutoff valve.

4. Hand tighten until snug, and then tighten ¼ turn more.

5. Replace thermocouple.

6. Replace control valve.

OBSERVED PROBLEM

Burner(s) does not light after

ODS/pilot is lit.

Delayed ignition of burner(s).

Burner backfiring during combustion.

High yellow flame during burner combustion.

Slight smoke or odor during initial operation

Heater produces a whistling noise when burner is lit.

Heater produces a clicking/ticking noise just after burner is lit or shut off.

POSSIBLE CAUSE REMEDY

1. Burner orifice is clogged.

2. Burner orifice diameter is too small.

3. Inlet gas pressure is too low.

.

1. Manifold pressure is too low.

2. Burner orifice is clogged.

1. Burner orifice (see Cleaning

and maintenance Page18) or replace burner orifice.

2. Replace burner orifice.

3. Contact your gas supplier.

1. Burner orifice is clogged or damaged.

2. Burner is damaged.

3. Gas regulator is damaged.

1. Contact your gas supplier.

2. Clean burner (see Cleaning

and maintenance Page 18) or replace burner orifice.

1. Clean burner orifice (see

Cleaning and maintenance

Page 18) replace.

2. Contact Dealer or Customer

Service.

3. Replace gas regulator.

1. Dirty or clogged burner.

2. Not enough air.

3. Gas regulator is defective.

4. Inlet gas pressure is too low.

1. Residues from manufacturing process.

1. Check burner for dirt and debris.

If found, clean burner (see

Cleaning and Maintenance

Page18).

2. Replace gas regulator.

3. Contact your gas supplier.

4. Check inlet pressure.

1. Problem will stop after a few hours of operation.

1. Turning control knob to high (5) position when burner is cold.

2. Air in gas line.

3. Air passageways on heater are blocked.

4. Dirty or partially clogged burner orifice.

1. Metal is expanding while heating or contracting while cooling.

White powder residue forming within burner box or on adjacent walls or

1. When heated, the vapors from furniture polish, wax, carpet furniture cleaners, etc., turn into white powder residue.

20

1. Turn control knob to low (1) position and let warm up for a minute.

2. Operate burner until air is removed from line. Have gas line checked by local propane/LP Gas Company.

3. Observe minimum installation clearances (Figure 4, page 9)

4. Clean burner (see Cleaning and

Maintenance Page 18) or replace burner orifice.

1. This is common with most heaters. If noise is excessive, contact qualified service technician.

1. Turn heater off when using furniture polish, wax, carpet cleaner or similar products.

When ignitor button is pressed in,

1. Ignitor is positioned wrong.

2. Ignitor electrode is broken.

3. Ignitor electrode is not connected to ignitor cable.

4. Ignitor cable is pinched or wet.

5. Broken ignitor cable.

6. Bad piezo ignitor.

1.Replace ignitor.

2.Replace ignitor.

3.Reconnect ignitor cable.

4.Free ignitor cable if pinched by any metal or tubing. Keep ignitor cable dry.

5.Replace ignitor cable.

6.Replace piezo ignitor.

When ignitor button is pressed in, there is no spark at

ODS/pilot.

1.Gas supply is turned off or equipment shutoff valve is closed.

2.Control knob not fully pressed in while pressing ignitor button.

3. Air in gas lines when installed.

4.ODS/pilot is clogged.

5.Gas regulator setting is not correct.

6.Bad piezo ignitor.

7.Depleted gas supply.

1.Turn on gas supply of open equipment shutoff valve.

2.Fully press in control knob while pressing ignitor button.

3.Continue holding down control knob.

Repeat igniting operation until air is moved.

4.Clean ODS/pilot (see Cleaning and

Maintenance Page 18) or replace

ODS/pilot assembly.

5.Replace gas regulator.

6.Turn control knob to Pilot position.

7.Contact your local gas company.

ODS/pilot lights but flame goes out when control knob is released

1.Control knob is not fully pressed in.

2.Control knob is not pressed in long enough.

3.Equipment shutoff valve is not fully open.

4.Thermocouple connection is loose at the control valve.

5.Thermocouple damaged.

6.Control valve damaged.

1.Press in control knob fully.

2. After ODS/pilot lights, keep control knob pressed in 30 seconds.

3.Fully open equipment shutoff valve.

4.Hand tighten until snug, and then tighten

1/4 turn more.

5.Replace thermocouple.

6.Contact Dealer or Customer Service.

REPLACEMENT PARTS

REPLACEMENT PARTS

NOTE: Use only original replacement parts.

This will protect your warranty coverage for parts replaced under warranty.

When calling Customer Service, or your dealer, have ready:

Your Name

Your Address

Mode and serial numbers of your heater

How heater was malfunctioning

PARTS UNDER WARRANTY

Contact authorized dealers of this product.

Type of gas used (propane/LP or NG)

Purchase date

If they can’t supply original replacement parts, Warranty card

Call the KOZY WORLD PHONE NUMBER Usually, we will ask you to return

(814)643-1775 for referral information.

PARTS NOT UNDER WARRANTY

Contact authorized dealers of this product.

If they can’t supply original replacement part(s),

Call KOZY WORLD PHONE NUMBER

(814)643-1775 for referral information.

When calling Customer Service, have ready

Model number of your heater

The replacement part number

21

PARTS LIST

This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 21 of this manual.

KEY NO PART NUMBER DESCRIPTION

1

2

3

4

5

6

7

8

9

10

SIT545-200

RV83FI -4/9

FBB28D01-B

NDD0308 x 400

QD250T007

QD250T006

QD250T005

QD250T003

QD250T004

YDF06

22

T-STAT VALVE

REGULATOR

BURNER ASSEMBLY

ODS

ODS OUTLET TUBE

ASSEMBLY

ODS OUTLET TUBE

ASSEMBLY

ODS INLET TUBE ASSEMBLY

INLET TUBE ASSEMBLY

OUTLET TUBE ASSEMBLY

GAS SELECTOR VALVE

ASSEMBLY

QUANTITY

1

1

1

1

1

1

1

1

1

1

PARTS LIST

This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 21 of this manual.

23