документацию FR7GH Heat Pump Compressor R134a 220

документацию FR7GH Heat Pump Compressor R134a 220
FR7GH
Heat Pump Compressor
R134a
220-240V 50/60Hz
General
Code number
103G6692
Approvals
EN 60335-2-34, UL984, CCC
Compressors on pallet
80
Application
Application
HBP
Frequency
Hz
50
60
Evaporating temperature
°C
-15 to 15
-15 to 15
V
198 - 254
198 - 254
Voltage range
Max. condensing temperature continuous (short)
°C
60 (70)
60 (70)
Max. winding temperature continuous (short)
°C
125 (135)
125 (135)
Hz
50
60
Cooling requirements
Frequency
Application
LBP MBP HBP LBP MBP HBP
32°C
–
–
O
–
–
O
38°C
–
–
O
–
–
O
43°C
–
–
O
–
–
O
Remarks on application:
S =Staticcoolingnormallysuficient
O = Oil cooling
F1 = Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
F2 = Fan cooling 3.0 m/s necessary
SG =Suctiongascoolingnormallysuficent
–
= not applicable in this area
Motor
Motor type
CSIR
LRA (rated after 4 sec. UL984), HST | LST
A
9.1
Cut in Current, HST | LST
A
9.1
–
–
Resistance, main | start winding (25°C)
Ω
8.8
12.0
Design
Displacement
cm3
6.93
Oil quantity (type)
cm3
450 (polyolester)
Maximum refrigerant charge
Free gas volume in compressor
g
900
3
1350
kg
10.6
cm
Weight without electrical equipment
Dimensions
Height
mm A
196
B
191
B1
–
B2
Suction connector
Process connector
Discharge connector
Oil cooler connector
Connector tolerance
–
location/I.D. mm | angle C
8.2 | 30°
material | comment
Cu-plated steel | Al cap
location/I.D. mm | angle D
6.2 | 30°
material | comment
Cu-plated steel | Al cap
location/I.D. mm | angle E
8.2 | 25°
material | comment
Cu-plated steel | Al cap
location/I.D. mm | angle F
6.2 | 25°
material | comment
Cu-plated steel | Al cap
I.D. mm
±0.09
Remarks:
Dec 2011
Manufactured by Secop for Danfoss - DEHC.ED.400.L7.02 / 520N1198
1/2
220V, 50Hz, fan cooling F2
EN 12900 Household (CECOMAF)
Evap. temp. in °C
-45
-40
-35
-30
-25
-23.3
-20
Capacity in W
-15
-10
-6.7
-5
0
5
7.2
10
15
199
255
301
327
417
525
580
655
807
20
Power cons. in W
165
192
209
217
239
258
266
274
28
Current cons. in A
1.38
1.47
1.53
1.55
1.63
1.70
1.72
1.76
1.81
COP in W/W
1.21
1.33
1.44
1.51
1.74
2.04
2.18
2.39
2.80
-15
-10
-6.7
-5
0
5
7.2
10
15
225
294
348
379
482
607
668
753
924
220V, 60Hz, fan cooling F2
EN 12900 Household (CECOMAF)
Evap. temp. in °C
-45
-40
-35
-30
-25
-23.3
-20
Capacity in W
20
Power cons. in W
184
217
239
251
284
317
331
350
383
Current cons. in A
1.31
1.41
1.49
1.53
1.65
1.79
1.86
1.94
2.10
COP in W/W
1.22
1.35
1.45
1.51
1.70
1.91
2.02
2.15
2.42
-15
-10
-6.7
-5
0
5
7.2
10
15
1005
220V, 50Hz, fan cooling F2
ASHRAE
Evap. temp. in °C
-45
-40
-35
-30
-25
-23.3
-20
20
Capacity in W
246
316
372
405
516
652
720
814
Power cons. in W
165
192
209
217
239
258
266
274
288
Current cons. in A
1.38
1.47
1.53
1.55
1.63
1.70
1.72
1.76
1.81
COP in W/W
1.49
1.64
1.78
1.86
2.16
2.52
2.71
2.97
3.49
-15
-10
-6.7
-5
0
5
7.2
10
15
278
363
430
469
598
753
830
936
1151
220V, 60Hz, fan cooling F2
ASHRAE
Evap. temp. in °C
-45
-40
-35
-30
-25
-23.3
Capacity in W
-20
20
Power cons. in W
184
217
239
251
284
317
331
350
383
Current cons. in A
1.31
1.41
1.49
1.53
1.65
1.79
1.86
1.94
2.10
COP in W/W
1.51
1.67
1.80
1.87
2.11
2.37
2.50
2.68
3.01
Accessories for
PTC starting device
FR7GH
Figure
6.3 mm spade connectors
4.8 mm spade connectors
a1
Code number
Test conditions
EN 12900/
CECOMAF
ASHRAE
–
Condensing temperature
55°C
55°C
–
Ambient temperature
32°C
32°C
Starting relay
6.3 mm spade connectors
a2
117U6016
Suction gas temperature
32°C
32°C
Start. capacitor 80 µF
6.3 mm spade connectors
c
117U5015
Liquid temperature
55°C
32°C
Cover
b
103N2011
Cord relief
d
103N1010
Mounting accessories
Protection screen for PTC
g
–
Bolt joint for one comp.
Ø: 16 mm
118-1917
Bolt joint in quantities
Ø: 16 mm
118-1918
Snap-on in quantities
Ø: 16 mm
118-1919
Code number
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to
productsalreadyonorderprovidedthatsuchalterationscanbemadewithoutsubsequentialchangesbeingnecessaryinspeciicationsalreadyagreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.