MODEL: SP12C7 Operating Manual (Portable 4 gas detector)

Add to my manuals
21 Pages

advertisement

MODEL: SP12C7  Operating Manual (Portable 4 gas detector) | Manualzz

MODEL: SP12C7

(Portable 4 gas detector)

Operating Manual

Guarantee and Repair

Senko Co., Ltd. guarantees the products of SP series for 24 months from the shipping date and repairs or replaces the defected product during warranty period at no cost. Nevertheless, Senko is not responsible for the following cases and would not repair or replace the product at no cost, such cases as the product has been purchased through the route that Senko does not approve, or as the product has been damaged or deformed mechanically by misuse of the user, or as the product has not been calibrated or replaced the parts according to processes in the operating manual.

In the event that any defect or issue of the product occurred during warranty period, Senko will cover all the expenses except transportation fee. After the period of warranty, the expenses of repair or replacement of the product and transportation will be in principle borne by the user. Senko will not be responsible for any indirect occurrence or accident and/or damage during the use of the product, and the guarantee shall be limited to the replacement of parts and product. The guarantee is applied only to the users who purchased the product at Senko’s authorized dealers or agents, and the guarantied repair is to be performed by the expert engineers of Senko’s authorized aftercare center.

Product Introduction

SP2nd is Simple Gas Alarm Detector that is required to protect users’ safety at dangerous work environments. The apparatus can indicate simultaneously the concentration of gases (Oxygen, Carbon Monoxide, Hydrogen Sulfide, Hydrogen,

Sulfur Dioxide, Hydrogen Chloride, Ammonia and etc.) on a digital LCD monitor, and the methods of operation and calibration are easy and convenient.

This instrument alerts accurately the alarm circumstances to operators and workers for their safety with its functions of loud alarm sound and vibration, when higher gas concentration than normality is detected. Besides, it is available for users to check upon occasion and adjust the value of alarm to the work environment on demand, since it has the function of indicating minimal and maximal concentration of the gases. It is also possible to prevent in advance workers from the danger of exposing for a definite period of time to such toxic gases as Hydrogen Sulfide(H

2

S), Carbon Monoxide(CO) and Sulfur Dioxide(SO

2

) by its function of STEL(Short Term Exposure Limit) and TWA(Time Weighted

Average).

01

Contents of Operating Manual

Product Specification ----------------------------------- 03

Names of Exterior and Display --------------------- 04

Start and End of Operation --------------------------- 05

Operation Method ----------------------------------- 06

Backlight ----------------------------------------------- 07

Start and End of Sensor ------------------------------- 08

Calibration ------------------------------------------------- 08

Method of Alarm Set and Display ----------------- 10

Battery & Sensor replacement --------------------- 13

Applicable Battery and External Pump ---------- 14

Notice for User --------------------------------------- 16

02

1. Product Specification(SP12C7)

Vibrator Alarm

Power

Applicable

Temperature &

Humidity

Explosion proof

Case

Standard

Accessories

Option

Dimensions

Weight

MODEL

Detecting Gas

Detecting Range

O2

0~30%Vol

Sensor Type

Sampling Method

Electrochemical

Display

Audible Alarm

Visual Alarm

CO

0~500ppm

SP12C7

Electrochemical

H2S

0~100ppm

Electrochemical

Diffusion

Digital LCD

90dB

Red LED

Vibration Alarm

Alkaline battery 2EA, Rechargeable NI-MH battery pack

EEx ia IIC T4 / IP67

Clear polycarbonate with thermal-plasticelastic (TPE) overmold.

Belt Clip, Charger

Sampling pump(SP-Pump101)

54mm(W) x 135mm(H) x36.5 mm(D)

240g

EX

0~100%LEL

Catalytic

-20℃ ~ +50℃, : 10% ~ 95% RH (non-condensing)

03

2. Names and Functions of Exterior

1

2

3

4

5

1. Gas sensor

2. Buzzer

3. LCD display

4. On/Off Key

5. Key

LCD display symbols

6

7

8

9

10

6. Alarm LED

7. Fastening clip

8. Type label

9. Charging contacts

10. Battery pack

04

3. Start and End of Operation

Instrument Power-On

Press Power key for 3 seconds, and power is turned on displaying 3, 2, and 1 in order on the monitor. (Power won’t turned on, if pressing the Power key is stopped before 3 seconds) Afterwards during the instrument is being stabilized, it displays consecutively A1 & A2 set values of LEL Gas, A1 & A2 set values of O2 Gas, A1 set value of CO Gas, A2 set value of CO Gas, set values of STEL & TWA, A1 set value of

H2S Gas, A2 set value of H2S Gas, and set values of STEL & TWA on the monitor.

When the instrument is stabilized after the display of the above set values, it converts to Gas Detection Mode displaying the mark . At normal status, the mark disappears after 30 seconds, and the concentration of the gas detected of the moment is indicated.

OFF …

In the event that stabilization of the instrument fails, it would not convert to Gas Detection Mode, blinking the mark with alarm sound. In this case, calibration of the sensor or aftercare of the instrument is required.

Instrument Power-Off

Press Arrow key for 3 seconds at the state of pushing Power Key simultaneously, and power is turned off displaying 3, 2, and 1 in order on the monitor with turning on LED Lamp and alarm.

OFF

<Caution> Appropriate calibration of the instrument is always required prior to the operation at work sites. Make sure if the instrument makes the proper detection response to the pertinent gas and if the region of the gas detection is not blocked with foreign materials that interfere with the gas detection.

05

4. Operation Method

Detection Mode

The instrument is converted to Gas Measure Mode as below, when power is turned on. Gas Measure Mode indicates the concentration of gas and the remained capacity of battery on

LCD, and it displays the gas concentration of Oxygen by %,

Inflammable Gas by %LEL, H2S and CO Gas by ppm units. In the event that the concentration of the specific gas changes, it indica

-tes the value of concentration in real-time. If it exceeds A1 or A2 Alarm standard

(or STEL / TWA), the measured value and A1 or A2 (icon in case of STEL / TWA) is displayed at one second interval in turn alerting by alarm sound and vibration.

As of A1, the instrument program will be converted to the original condition and starts the operation, when the concentration value of the measured gas returns to the normal state. (LED and LCD Backlight are displayed continuously and the alarm sound stops, if power key is pressed during the alarm sounds. During the alarm sound, the measured value and A1 or A2 are displayed in turn on LCD.) In case of

A2, power should be disconnected in order to stop the alarm. When the concentration value of the measured gas exceeds the maximum measuring range, it is indicated as the maximum value. And LED, alarm sound and vibration applicable to A2 Alarm Standard operate together

Indication of Peak Value and TWA & STEL Value

At Gas Measure Mode, Peak value is displayed (Peak values of all 4 sensors) by pressing Arrow key for 3 seconds, the value of TWA (only for CO and H2S) is shown by pressing it again, and that of STEL (only for CO and H2S) is indicated consecutively by pressing it once more. The program returns to Gas Measure Mode by pressing Power key at the state indicating Peak, TWA and STEL. And it reverts automatically to Gas Measure Mode as well without using the button for 30 seconds at the state of Peak, TWA and STEL.

Password Mode

Password input screen appears by pressing Power key for 5 seconds. Number changes from far left to the right side. It moves upward by each 1 step and blinks by pressing Arrow key, and the blinking 2nd number moves the position by pressing Power key. If key.

06

If you press Arrow key, the number moves upward, and the 3rd number blinks and moves the position by pressing Power key.

After completing the change of the last number and enter the Power key, icon blinks with 0.5 second alarm sound if the password is correct. As previously explained, the program moves to Calibration Mode by pressing Move key, and moves to Alarm Set Mode by Power key.

If the password is incorrect, it returns to Gas Measure Mode altering the alarm sound.

Password Change Mode

When password icon blinks by moving as the above drawings, press Power key.

Then the existing password is displayed blinking from the first digit. If the new password is entered, the existing password is deleted and the new password appears. When the same password is put repeatedly at RE, the password will be changed and the program will return Password Change Mode where icon is blinking. If further change of password is not required, return to Gas Measure

Mode by using Arrow key.

<Caution> The initial password is set as 000. It is impossible to enter Calibration or Alarm Set Mode, if the operator can’t remember the new password after changing it. Please be sure not to forget the password.

07

5. LCD Backlight

LCD Backlight

At the state of Gas Detection Mode indicating the concentration of 4 kinds of gases simultaneously, LED Backlight is turned on by the short press on Arrow key, and it is turned off by pressing again once more. It enables the operator to view the measured value even at dark atmosphere.

Backlight will be automatically turned off after 10 seconds unless the button works.

6. Start and End of Sensor

Individual Sensor On/Off

<주의> cLr Mode is factory reset mode. Factory reset mode prohibits user except factory from using of cLr Mode. Please pay attention to it.

Press Power key for 5 seconds, After completing passwore and enter the Power key, letter ‘on’ blinks icon together. At this time, if press Power key, position move to next sensor and start/end of sensor selects by pressing Arrow key

** If press Key, repeat as follows. on -> oFF -> cLr(Factory reset)

Select number

Save value

Change sensor set

Save set

08

7. Calibration

Fresh air Calibration

Press Power key for 5 seconds and input password, sensor on/off, and icon will blink. Then press Arrow key to make icon blink. When Power key is pressed at the state, it converts to Calibration mode of the standby state.

Calibration will be processed, when Power key is pressed after entering to

Calibration mode of the standby state. Calibration will be completed by 3 time blinking of 4 sorts of gas concentrations, and the mark OK is displayed.

In the event that calibration fails, it would not convert to Gas

Detection Mode, blinking the mark with alarm sound. In this case, calibration of the sensor or aftercare of the instrument is required.

.

Standard Gas Calibration

Press Power key for 5 seconds and input password, sensor on/off, then icon will blink. And press Arrow key to see icon blink. The icon will blink, when the operator presses again Arrow key once more. Then it enters to Standard Gas

Calibration Mode of, as Power key is pressed.

When Standard Gas Calibration start, calibration gas concentration appears at device and calibration starts by setting gas concentration. Press Power key at last number of 4 th sensor, calibration starts automatically.

<Caution> Senko Co., Ltd. performs the initial calibration before the shipment.

Incorrectly calibrated value can reduce the accuracy of the product, as the calibrate d value is stored in the instrument. Calibration is in general to be performed monthly or quarterly, and can be adjusted according to frequency of the use.

09

<Caution> Fresh Gas Calibration should be performed at the environment of fresh air without any influence of other gases, since the calibration is performed on the assumption that the concentration of Oxygen is 20.9%, that of Inflammable Gas is

0%LEL, and the concentration of Toxic Gas is 0ppm in the fresh air. Accordingly it is not recommended to perform Fresh Air Calibration at the closed space, and it should be avoided to perform the calibration where gases can be inhaled by operators.

Start calibration

Change value

Save value

If Standard Gas Calibration starts, screen of detector is displayed sequentially according to gas kind. That is, calibration proceeds for 60 seconds as information for 4 sensor appears once 1 second. If you want to cancel calibration, press arrow key. Then press Power key, returns in Standard Gas Calibration entry ago.

Concentration of Standard Gas Calibration is saved by state that change only in case calibration completes without problems.

If calibration is ended without problems, writing 'OK' is appeared, and returns by

Gas Measure Mode if press this after power key.

Gas Value Gas Value

ADC값 60 second

Count down

ADC값 60 second

Count down

10

Concentration of Calibration Gas set at Instrument

Gas Combustible

(CH

4

Oxygen

18%vol

Carbon monoxide

100 ppm

Hydrogen

Sulfide

25 ppm

In the event that calibration fails, it would not convert to Gas

Detection Mode, blinking the mark with alarm sound. In this case, calibration of the sensor or aftercare of the instrument is required.

9. Method of Alarm Set and Display

Alarm Set

When Lock icon blinks after entering password, approach to A1 Alarm Value Set

Select Mode by pressing Power key. If Arrow key is pressed during blinking of icon, the program moves to Calibration Select Mode likely Sensor Calibration

Mode. Please pay attention to this point.

<Caution> Changing alarm value of TWA and STEL can be applied only to Carbon

Monoxide and Hydrogen Sulfide. The change of alarm standard of TWA and STEL can cause the fatal influence to the lives of operators and workers; therefore it must be set in accordance with the regulations of the relevant country and the standard of exposure at work site, if it is inevitably changed.

11

Alarm Set of Each Gas

A1 icon blinks, when Power key is pressed at Lock Blink Mode. It will be converted to A1 Alarm Mode by pressing Power key, and the blinking icon will be alternated in the sequence of A2, TWL, STEL and Password. If you want to approach to each Alarm Value Set Mode, enter it by pressing Power key.

A1 icon blinks by pressing Power key at Lock Blink Mode. And it is converted to %LEL Alarm Value Set Mode by pressing Power key again. After moving to %LEL

Alarm Value Set Mode, Alarm Value of %LEL, that has been input initially, blinks.

And the Alarm Value can be changed by the same method as password input.

Changing sequence of Alarm Value is %LEL, %vol, Oxygen, Carbon Monoxide and

Hydrogen Sulfide, and it returns to A1 Set Mode when the change of Alarm Value of each gas is completed.

Change value

Save value

Alarm Display

When A1 alarm occurs, and the operator recognizes it and presses Power key, only the sound and vibration of alarm stop, remaining LED alarm as the operation stale. When A2 alarm happens, the operator and workers should promptly escape from the work site. The alarm will stop, when power is turned off at the place where the concentration value of gas is normal after moving to a safe region. (If the instrument is operated again at an abnormal environment, the warning of test failure is displayed.)

<Caution> The value of alarm of the instrument is set according to the alarm standard of each gas that is required by international standard. Therefore alarm value of the relevant gas can be changed under the responsibility and approval of the administrator of the work site where the instrument is used.

12

<Note> In case of Inflammable Gas, it is determined by Alarm Set Mode to display %LEL or %VOL. When %LEL Alarm Value is changed, %LEL is displayed at

Calibration Mode. In the event that %VOL Alarm Value is changed, %VOL is indicated at Calibration Mode. If you don’t want the display by %VOL, move to the next step without changing the value at %VOL Alarm Value Change Mode.

Alarm Display

When STEL / TWA alarm occurs, it is indicated with the value of the measured concentration and alerts alarms of the same sound of alarm and vibration as that of A2 alarm. When STEL / TWA alarm occurs, the icon can be deleted only by

Power Off.

Primary battery alarm sounds repeatedly at 5 minute intervals when only a bar of battery icon is remained. Secondary battery alarm starts right before the end of power, and the power source finishes after 10 seconds from the outbreak of alarm.

In the event of failure of test or calibration, the icon of Test Failure is displayed with the sound of alarm.

1 st

Alarm

Alarm(A1)

Alarm Standard

In Exceeding Alarm

Value Set Primarily

LCD Display

Displaying Icon A1

& Concentration

2 nd Alarm(A2)

TWA

STEL

Low Battery

In Exceeding Alarm

Value Set

Secondarily

In Exceeding

Exposure

Concentration for 8 hour

In Exceeding

Exposure

Concentration for

15 minutes

Remained Battery

Capacity is small

(one bar)

Displaying Icon A2

& Concentration

Displaying Icon TWA

& Concentration

Displaying Icon STEL

& Concentration

Blinking of

Test Failure

Failure of Sensor Test

Failure of Calibration

Displaying Icon

Test Failure

Alarm & Vibration Display

Buzzer, LED

Buzzer

LED, LCD Backlight

13

Alarm Set Point

Gas Combustible Oxygen

Carbon monoxide

Hydrogen

Sulfide

A1

A2

20 %LEL

40 %LEL

19%

23%

30 ppm

60 ppm

10 ppm

20 ppm

TWA - - 30 ppm 10 ppm

STEL - -

9. Battery & Sensor replacement

200 ppm 15 ppm

When you replace the Battery and sensors of SP12C7, you need some instrument and components as below.

- Instrument : + driver, wrench(hexagon)

- Battery : Energizer No.E91, EN91 or GP rechargeable Battery GP210AAHCB

- Sensors for replacement

- Filters for replacement

Disassembly

- Turn off the power.

- Replace the sensor and battery , please refer to below drawing.

- After replacement, check the sensor fail and battery working.

6

7 6

2 3 4 5

6

1

1

1. Label(Membrane)

2. Front Cover

3. Sensor

4. PCB

6

5. Rear Cover

6. Machine Screw

7. Belt clip

8. Bolt(hexagon)

9. Battery

14

9

8

<Caution>

1. It is absolutely prohibited to replace battery at potential explosion or dangerous regions.

2. Replacement of components can be damage to intrinsic safety function.

3. The sensors published by SENKO should be used for replacement. Unsuitable function could be shown if another sensors use for replacement.

4. Disassembly should be necessary only for sensors & battery replacement. After the sensor replacement, the span gas calibration should be done.

10. Applicable Battery and External Pump

<Caution> It is absolutely prohibited to replace battery at potential explosion areas or dangerous regions. And the charger should be always used at the safe place, since it is not an explosion-proof product.

Specification of the applicable rechargeable battery and disposable battery is as below:

- Disposable Alkaline Battery: Energizer No. E91, Energizer No.EN91

- Rechargeable Ni-H Battery: GP BATTERY GP210AAHCB

It is not permitted to use other batteries for the instrument at dangerous regions.

When the unit is connected to battery charger, power source should be turned off without fail before charging. The state of charging is indicated on LED display of the charger..

**Red LED: charging / Green LED: completion of charging

Charging time of rechargeable battery is 5 hours, and it can be used for 12 hours at the state of general measuring.

<주의> Followings may cause the danger of explosion; to use the old battery and the new one together, to use different manufacturer’s battery; or to use the batteries of different specification. In order to avoid an accident, please use only the applicable batteries as specified above. Explosion can occur, when a battery is thrown into fire or disassembled with force. Disposal of the used battery should be performed according to the guide of the pertinent country or the work site.

15

Accessory(Optional) - External Pump (SP-Pump101)s

key has the function of On/Off, and the state of operation or trouble of the instrument can be recognized by LED lamp. When the leakage measurement or the measurement of concentration by inhalation of gas is required, it is available to measure gas concentration and leakage at the pertinent place by connecting the pump to the instrument. Prior to use, make sure that the instrument is tightly attached to the probe cover which is connected to the sensor.

**Please note that External Pump is the optional product that can be provided by the separate order.

Product specification(SP-Pump101)

Power Source

Continuous Operation Time

Applicable Temperature &

Humidity

AA Size Alkaline Battery(1 EA)

Available to Operate for 10 hours or longer

-20°C ~ +50°C / 5 ~ 95% RH

Exterior

Sampling Flux

Diagnosis Function

Dimension: 34mm(W) x 270mm(H) x 47 mm(D)

Weight: 200g (Including)

0.5 liter / minute

Deadlock Alarm, Alert of Insufficient (Red LEC Display)

16

Operation Flow Chart

17

Operation Flow Chart

Calibration & Configuration Flow

18

12. Notice for User

Please use the instrument in the range of the applicable temperature, humidity and pressure that are appropriate for the specification of the product. Using the instrument beyond this range may cause malfunction or glitch of the instrument. .

Gas concentration measurement value by the sensor or the instrument can vary according to the environment at site (temperature, pressure and humidity).

Therefore the calibration of the instrument should be performed at the same or similar environment as that of the instrument use (temperature, pressure and humidity).

If temperature changes sharply during use of the instrument (for instance, using the instrument at places of far different temperatures between indoor and outdoor), the value of the measured gas concentration can be changed suddenly. Please use it after the gas concentration value is stabilized.

Severe vibration or shock to the instrument may cause the sudden change of value of the measured gas concentration. Please use it after the value of gas concentration is stabilized. Excessive shock to the unit can lead to trouble of the sensor or the instrument.

19

Certificates

20

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement