Electra | DELTA 35 | Product benefits

electra 2008 air conditioning & HEATING catalogue
Ducted
LSN DCI
3.4 to 7.8 kW
p. 34
DNG DCI
4.3 to 8.8 kW
p. 36
LS
DNG
3.4 to 13.1 kW
p. 38
SMILY N
2.3 to 4.5 kW
p. 40
JKF
2.5 kW
p. 41
AWD
2.1 to 6.4 kW
p. 42
CCE 45
14 to 15 kW
p. 43
DUO/TRIO/QUATTRO DCI
5.3 to 14 kW
p. 44
DUO R410A
5.3 to 14 kW
p. 46
DUO/TRIO DELTA
4.5 to 6.6 kW
p. 48
Monobloc
Multisplits
1
WORLD
Range
p.50
Wall mounted
COMPACT F
2.1 to 5.5 kW
p. 52
WMZ
WNG
2.7 to 9.6 kW
p. 54
2.7 to 8.4 kW
p. 56
ECF
3 to 7.2 kW
p. 58
ECFXL
10.2 to 13.5 kW
p. 58
LS
3.4 to 11 kW
p. 60
EMDB
3.7 to 18 kW
p. 62
3.4 to 11 kW
p. 63
Floor/Ceiling
PXD
Cassettes
Ducted
Multisplits
DUO
2
electra 2008 air conditioning & HEATING catalogue
Heat pump
Cooling only
Fluid R410A
Fluid R407C
All Electra products
bear the CE mark.
G
E
N
E
R
A
L
N
O T
E
Fluid R22
ELECTRA participates in the
Eurovent certification programme.
Certified product are listed in the
directory published by Eurovent.
S
All values are specified for a 230V supply voltage. Nominal cooling capacity: International conditions : 27°C/19°C (wet bulb) – outside
air temperature 35°C/24°C (wet bulb) (Standards NF EN 255.2 – NF EN 814.2). Nominal heating capacity: International conditions:
20°C/12°C (wet bulb) – outside air temperature 7°C/6°C (wet bulb) (Standards NF EN 255.2 – NF EN 814.2). Acoustic levels: Global
acoustic pressure in dBa (1 m comfort range, 4 m industrial and chilled water) under nominal conditions: outdoor unit in an open area
against a reflective background – indoor unit: installation in an average sized room (PV – 0.5 s reverberation ) or acoustic capacity
depending on models.
3
6 production sites
in the world
With its state-of-the art manufacturing facilities benefiting from the most
up-to-date production methods, the Group has 6 production sites
throughout the world with a total annual capacity of 2,000,000 units.
To meet ever-changing market demands, we have structured our
design and manufacturing systems around each manufacturing site’s
specialisation.
Tillières
(France)
Barlassina
(Italy)
Shenzhen
(China)
Pons
(France)
Rishon-Le-Zion
(Israel)
Dong-Guan
(China)
Manufacture
of industrial
appliances for
world markets.
Aeraulics,
thermodynamics
and fluid
mechanics
R & D Centre.
Manufacture of
large capacity
air conditioning
and chilled water
production
appliances up to
1,000 kW as well
as convector fans.
Production of low
capacity residential
and semi-industrial
appliances.
Manufacture of
medium capacity
chilled water
production
appliances, chilled
water terminals,
convector fan and
air treatment units
Manufacture of
residential and
tertiary sector
appliances.
Production and
R & D Centre
for electronic
components
at Group level.
Surface area :
110,000 m².
Annual production :
180,000 units.
4
Surface area :
50,000 m².
Annual production :
30,000 units.
Surface area :
100,000 m².
Annual production :
1,000,000 units.
Surface area :
55,000 m².
Annual production :
72,000 units.
Surface area :
73,000 m².
Annual production :
500,000 units.
Surface area :
15,000 m².
Annual production :
5 million items
(PCB, RC, IAQ…).
electra 2008 air conditioning & HEATING catalogue
A group in continuous expansion
E
LECTRA was originally founded in 1947 and
now the Group has a worldwide presence.
Via its network of sales outlets, ELECTRA
is dedicated to the design, manufacture
and marketing of air conditioning systems adapted to
the most demanding markets. Thanks to our continuous
development programms, we offer a broad range of
products, for meeting today’s needs in the residential,
tertiary and industrial sectors.
Shenzhen (China)
Tillières (France)
Shenzhen (China)
5
Fluid
Innovation only
has meaning if it
includes respect for
the environment.
A
ll ELECTRA employees take pride in designing, manufacturing and marketing
products that always match users’ expectations and that are respectful of our
environment. Therefore, we are always seeking the balance between technology
and ecology on all of our products by complying with the most stringent
requirements in terms of quality and respect for the environment.
In line with this principle and with European directives, in all its appliances
ELECTRA uses environmentally friendly fluids that do not harm the ozone layer.
An HFC (hydro-fluoro-carbon) type fluid that protects the environment and the
ozone layer.
Environmental protection and sustainable development have always been
at the very core of our design preoccupations.
WEEE (Waste electrical and electronic equipment)
On 13th August 2005, the new European Directive on Waste Electrical
and Electronic Equipment (WEEE) came into force.
The Directive’s aim is to regulate the disposal of electronic waste by separating
its treatment from that of household waste.
Selective collection systems are being put in place to recover all WEEE
with the view to recycling.
This Directive requires air conditioning appliance manufacturers and distributors to :
- Mark certain models marketed after 13th August 2005.
- Meet financial obligations associated with end-of-life appliance recycling.
As users of our products, and on those products covered by the Directive, you
will observe a pictogram (see illustration below) on the Maker’s plate representing
a «crossed-out refuse bin». This pictogram is intended to inform the user that
the appliance in question must be disposed of separately from household waste.
As part of its sustainable development policy, along with the entire profession,
Electra is committed to abiding by this new European initiative. Our environment
is precious, let’s preserve it.
6
electra 2008 air conditioning & HEATING catalogue
The labelling classifies
air conditioning systems
in 7 categories
(from A to G) in relation
Energy
Manufacturer
Outside unit
Inside unit
A
B
C
D
consumption. Those
appliances with the
best energy efficiency
are awarded an A label
the label) those with the
lowest energy efficiency
a G label (Red colour
arrow). This label also
Less efficient
Cooling and heating
capacity, Noise level)
and allows the user
to compare the efficiency
of different products.
A
E
F
G
Annual energy consumption,
kWh in cooling mode
295
(Actual consumption will depend
on how the appliance is used
and climate)
Cooling output
kW
Energy efficiency ratio
2.2
3.3
Ful load (the higher the better)
Type
Cooling only
fl
fl
Cooling + Heating
includes a certain number
of details (Brand, Model,
UE 7 DCI
UI Delta 7 DCI
More efficient
to their energy
(Green colour arrow on
Air-conditioner
Air cooled
Water cooled
Heat output
Heating performance
A: higher
kW
G: lower
Noise
(dB(A) re 1 pW)
Further information is contained
in product brochures
Norm EN 814
Air-conditioner
Energy Label Directive 2002/31/EC
2.5
A
30
Indication of annual energy consumption
Based on a standard model, this annual consumption
is calculated by multiplying the total capacity by an
average running time of 500 hours per annum in Cooling
mode and under full load.
• Cooling capacity
The refrigerating capacity is defined as the cooling
capacity in kW of an appliance, running in Cooling mode
under full load.
EER or Energy Efficiency Ratio
This is the ratio between the refrigerating capacity
and the amount of electricity consumed to attain it.
In other words, the higher the EER, the better the energy
efficiency.
Energy Efficiency Categories* in cooling mode
A EER > 3.2 E 2.6 > EER > 2.4
B 3.2 >EER > 3.0 F 2.4 > EER > 2.2
C 3.0 >EER > 2.8 G 2.2 > EER
D 2.8 >EER > 2.6
• Heating Capacity
Heating capacity is defined as the Heating capacity in
kW of an appliance running in Heating mode and under
full load.
COP or Coefficient of Performance
This is the ratio between the Heating capacity and the
quantity of electricity consumed to attain it. In other
words, the higher the COP, the better the energy
efficiency.
Energy Efficiency Categories* in heating mode
A COP > 3.6
E 2.8 > COP > 2.6
B 3.6 >COP > 3.4
F 2.6 > COP > 2.4
C 3.4 >COP > 3.2
G 2.4 > COP
D 3.2 >COP > 2.8
* only for splits and multisplits.
7
Remote controls
W
ith their compact size
a whole host of sophisticated functions such as :
and excellent ergonomics,
• Night time slow running. This function adapts the
ELECTRA infrared remote controls
provide perfect user comfort. As a
night time temperature in an ideal manner, whilst
RC4 model
clever blend of design and high technology, these
of up to 7%.
remote controls with a signal transmission range of
• “I FEEL” function. This innovation from ELECTRA’s
8 m, enable easy day-to-day control of a complete
range of functions to make users’ lives easier.
These remote controls allow the user to
select the operating mode (Heating,
better temperature control.
provides for deferred, or
to choose the desired
programmed, unit ON/
temperature, the fan speed
OFF control and results in
and the air sweeping function as
RC3 model
R & D department enables the point of temperature
measurement to be moved, leading to
• Programming. This function
Cooling, Dehumidification),
8
reducing consumption and creating energy savings
well as to programme
optimised user comfort along
RC6 model
with energy savings.
RC5 model
electra 2008 Air conditioning & Heating CATALOGUE
Programming
• Controlling up to 15 zones (32 units)
with individual unit time programming
and temperature setting functions.
• 7 day programmable thermostat with
2 daily setting ranges.
basic functions
RCW2 model
Multi-functions remote controls
at the forefront of ergonomic design
• Heating/Cooling electronic regulation.
• Automatic fan ventilation or 3 fixed speeds
fan ventilation.
• Night time slow running.
• Dehumidification.
centralised control
• Easy functions duplication for quick
programming.
• “Master/Slave” function.
• Time delayed start up of air treatment units
(multiple unit installations).
• Permanent “I feel” function (single unit
installations).
9
Airconet
Remote management of your air conditioning network
Airconet is a complete, powerful and user-friendly system providing remote management of air conditioning
installations in an overall and customised manner :
• Centralised control of a group of indoor units (building, floor…).
• Individual control in each pre-defined room and zone.
Irrespective of the type of building, by way of a simple PC connected to the Internet or to the building's local
network, Airconet provides total control of a complete air conditioning system.
In fact, from the Airconet communication gateway connected to each of the indoor units and depending on
access rights granted, the user can regulate blown air temperatures and fan speeds and even receive e-mail
or SMS alerts regarding any system malfunctions…
Installation architecture
LAN/WEB
SMS
Managed site
Basic configuration : 1 Airconet communication gateway module Å per site capable of managing up to 247 indoor units, 1 MIU Ç per indoor unit
depending on the unit type.
NB. Each distributor needs to have 1 converter (SP000000080) Ñ to loan out to installers. This converter is required for initial installation configuration.
10
electra 2007 air conditioning catalogue
Advantages :
Benefits :
• User-friendly, straightforward,
• Improved occupant comfort (e.g.
efficient and autonomous interface.
timing a unit to start operating before
• Plug and Play installation,
the arrival of the client/occupant).
no software installation, modem
• Lower energy bills by way of
integrated in the communication
energy savings derived from overall
Gateway.
installation control, and therefore
• Integrated system supervision,
close control of energy consumption.
easy to use.
• Simplified management and
• Choice of languages.
improved maintenance thanks
• Perfect compatibility with
to optimal installation control
Windows operating systems :
and real time interventions.
XP, 2000, NT, 98…
• Extended equipment service life.
• Up to 247 units managed by
• Completely upgradeable system.
a single communication Gateway.
• Real time alerts by e-mail or SMS
• Very low investment.
of any installation malfunction.
Principle :
The heart of the system is the Airconet communication
gateway. This is a module installed on site and connected,
on the one hand to all the air conditioning units to be
managed by way of an MIU (Modbus Interface Unit) and,
on the other hand, to a LAN/WEB network. In this manner,
the user can connect to the communication gateway via a
PC with an internet connection. Thanks to the Plug & Play
system there is no requirement for the user to install any
special software as this is already loaded in the Airconet
communication gateway. Via the PC’s internet navigator,
it is possible to set and alter parameters such as room
temperatures and timer programming as well as to be
alerted in the event of any possible malfunctions.
Several user levels
Level
1
2
3
4
5
User
Possibilities
Company employee
Reception manager (hotels…)
Maintenance manager
Technician
Supervisor/Developer
Local normal control of an individual unit
Centralised normal control of all units
Communication gateway information verification
System definition
Database and parameters
CUSTOMER
SERVICE
Communication gateway Å
Range
Size
Part number
Managed with all indoor units
Managed with all sizes
AIRCONET006
MIU - Communication cards Ç
Range
DC Inverter
R410A
R407C/R22
Model
Size
Part number
CK DCI
PXD DCI
LSN DCI
ECF DCI
WNG N
TOP
PXD N
ECF N
ECF XL N
DNG
9/12/18/21/24
9/12/18/24/28
9/12/18/24
9/12/18
30
9/12
9/12/15/18/24/30
9/11/15/18
24/30/36/45
18/24/30/37/44
Please, consult us
Please, consult us
Please, consult us
Please, consult us
Please, consult us
Please, consult us
Please, consult us
Please, consult us
Please, consult us
Please, consult us
CCE 45
all sizes
NOTE 1 : Each “Airconet XXX” reference includes the communication board (MIU) as well as the connections required for connecting to the unit.
NOTE 2 : In addition to 40 MIU boards connected to the communication gateway, a REPEATER (free of charge supply) must be installed.
11
DCI - R410A - R407C range
EUROPE range
12
EUROPE
AMBIANCE
electra 2007 air conditioning catalogue
DELTA DCI
PLATINIUM DCI
COMPACT F
WNG N
TOP N
CASSETTES
CN DCI
ECF / ECF XL DCI
ECFN / ECF XL N
dUCTED
14
16
18
20
22
24
26
28
FLOOR / CEILING
PXD DCI
PXD N / NSA
30
32
34
36
38
LS DCI
DNG DCI
LS / DNG
MOBILE / MONOBLOC
40
41
SMILY / N
JKF
WINDOWS-COLUMN
42
43
AWD
CCE
MULTISPLITS
44
46
48
DUO/TRIO/QUATTRO DCI
DUO/TRIO DELTA
DUO R410A
13
WORLD
ARMOIRES
wall mounted
Wall mounted
DELTA DC
INVERTER
Product benefits
Flexibility and comfort of use.
Extended operating range.
● Optimal
efficiency : Class A energy label (depending on models).
● Reduced
noise levels.
● High
efficiency filtration.
● Electronic
regulation and programming.
● Automatic
treated air sweeping.
● R410A
«green» fluid.
● Optimal
temperature regulation.
● Heating
mode operation down to outdoor temperatures of -15 °C.
●
●
Wall monted range
: Platinium DC INV Delta DC INV
: Compact F WNG N
Top
DELTA 7/9 DCI
RC7 Remote control
DELTA 12/18 DCI
OU 7/9/12 DCI
OU 18 DCI
Accessories
Mounting bracket
Condensate lift pump
14
• Part number
• Part number
DELTA 7 DC INV
7ACTL0016
SAE3100
DELTA 9 DC INV
7ACTL0016
SAE3100
DELTA 12 DC INV
7ACTL0016
SAE3100
DELTA 18 DC INV
7ACTL0016
SAE3100
EUROPE
AMBIANCE
electra 2008 Air conditioning & Heating CATALOGUE
4 Heat Pump models DCI : from 2 500 to 5 300 W
DELTA 7 DCI
DELTA 9 DCI
2.2
0.66
3.33/A
2.5
0.75
3.33/A
3.5
1.03
3.39/A
v-10 °/46 ° Dry Bulbk
5
1.56
3.2/B
2.5
0.73
3.42/B
2.8
0.82
3.41/B
3.6
1.05
3.42/B
v-15 °/24 ° Dry Bulbk
5.3
1.55
3.41/B
m3/h
dB(A)
l/h
kg
mm
300/350/400
30/33/36
1
7
680x185x250
ESP022275
270/350/420
32/35/39
1
7
680x185x250
ESP022276
350/450/550
29/33/39
1.5
8
840x185x250
ESP022277
480/620/720
34/41/44
2
11
900x205x295
ESP022278
m3/h
dB(A)
1400
54
Rotary DC Inverter
35
760x245x545
ESP061601
1390
54
Rotary DC Inverter
36
830x245x545
ESP061602
1390
55
Rotary DC Inverter
37
830x245x545
ESP061603
2160
53
Scroll DC Inverter
38
795x290x610
ESP061597
Linking specifications between indoor and outdoor units
Power supply
Power supply side
Indoor
Power cable section
mm2 3x1.5
Fuse rating am
A
12
Electrical connections
mm2 4x1.5
Indoor
3x1.5
12
4x1.5
Indoor
3x1.5
16
4x1.5
Indoor
3x1.5
20
5x1.5
Linking pipes
Max. lenght
Max. height
Suction pipe diameter
Liquid pipe diameter
15
10
3/8”
1/4”
15
10
3/8”
1/4”
15
10
1/2”
1/4”
Cooling Capacity
Power Input
EER/Energy Label
Outdoor temperature operating limits
kW
kW
Heating Capacity
Power Input
COP/Energy Label
Outdoor temperature operating limits
kW
kW
Indoor Units
Air flow (LS/NS/HS)
Acoustic pressure to 1 m (LS/NS/HS)
Dehumidification
Weight
Dimensions (WxDxH)
• Part number 1~230 V
Outdoor Units
Air flow
Acoustic pressure to 1 m
Compressor type
Weight
Dimensions (WxDxH)
• Part number 1~230 V
°C
°C
kg
mm
m
m
Inches
Inches
15
10
3/8”
1/4”
DELTA 12 DCI
DELTA 18 DCI
15
WORLD
ARMOIRES
DELTA DC INVERTER SERIES
Wall mounted
PLATINIUM DC INVERTER
Product benefits
Perfect comfort, unequalled unobtrusiveness, great accuracy
in maintaining the desired temperature and controlling air quality.
● R410A
«green» fluid.
● Optimal
efficiency : Class A energy label (depending on models).
● Heating
mode operation down to outdoor temperatures of -15 °C.
● Optimal
temperature regulation.
● Electronic
regulation and programming.
● AQS
filtration : electrostatic filter + Ioniser.
● Automatic
treated air sweeping.
● LCD
screen.
● Fluid
pre-charged at the factory for up to 20 m pipe lengths
(depending on models).
● Compatible
with AIRCONET regulation (PLATINIUM 18 DCI).
●
Wall monted range
: Platinium DC INV Delta DC INV
: Compact F WNG N
Top
PLATINIUM 21 DCI
RC3 Remote control
OU PLATINIUM 18 DCI
Accessories
Condensate lift pump
16
PLATINIUM 25/28 DCI
• Part number
PLATINIUM 21
DC INV
SAE3100
OU PLATINIUM 25/28 DCI
PLATINIUM 25
DC INV
SAE3100
PLATINIUM 28
DC INV
SAE3100
EUROPE
AMBIANCE
electra 2008 Air conditioning & Heating CATALOGUE
3 Heat Pump models DCI : from 6500 to 8 500 W
PLATINIUM DC INVERTER
SERIES
PLATINIUM 25 DCI
PLATINIUM 28 DCI
6 (1.5-6.7)
1.99
3.01/B
6.8 (1.5-7.5)
2.25
3.0/B
v-10 °/46 ° Dry Bulbk
7.8 (1.5-8.8)
2.59
3.0/B
6.5 (1.8-7.9)
1.90
3.42/B
7.0 (1.5-8.8)
2.19
3.2/C
v-15 °/24 ° Dry Bulbk
8.5 (1.5-9.5)
2.65
3.2/C
m3/h
dB(A)
l/h
kg
mm
620/760/900
34/45
2
15
1060x210x295
ESP022280
700/850/1000
38/47
2.5
15
1060x210x295
ESP022282
950/1100/1250
44/51
3
18.5
1200x236x340
ESP022284
m3/h
dB(A)
2860
55
Scroll DC Inverter
46
846x302x690
ESP061598
3600
56
Twin Rotary DC Inverter
64.5
950x412x835
ESP061599
3600
56
Twin Rotary DC Inverter
66
950x412x835
ESP061600
Linking specifications between indoor and outdoor units
Power supply
Power supply side
Indoor
Power cable section
mm2 3x2.5
Fuse rating am
A
20
Electrical connections
mm2 4x2.5
Outdoor
3x2.5
20
4x2.5
Outdoor
3x2.5
20
4x2.5
Linking pipes
Max. lenght
Max. height
Suction pipe diameter
Liquid pipe diameter
30
15
5/8”
3/8”
30
15
5/8”
3/8”
Cooling Capacity
Power Input
EER/Energy Label
Outdoor temperature operating limits
kW
kW
Heating Capacity
Heating Capacity at -15 °C
Power Input
COP/Energy Label
Outdoor temperature operating limits
kW
kW
kW
Indoor Units
Air flow (LS/NS/HS)
Acoustic pressure to 1 m (LS/HS)
Dehumidification
Weight
Dimensions (WxDxH)
• Part number 1~230 V
Outdoor Units
Air flow
Acoustic pressure to 1 m
Compressor type
Weight
Dimensions (WxDxH)
• Part number 1~230 V
°C
°C
kg
mm
m
m
Inches
Inches
30
10
1/2”
1/4”
WORLD
ARMOIRES
PLATINIUM 21 DCI
17
COMPACT F
Wall mounted
(R410A)
Product benefits
New design with flat panet grill.
Compact and lightweight for easy installation and maintenance.
●2
ventilation speed plus automatic speed.
● Cold/hot
Automatic regulation.
● Automatic
vertical treated air sweeping.
● High
efficiency filtration.
● COMPACT
9 & 12 (available with class C on request).
●
●
Wall monted range
: Delta DCI
Platinium DCI
: COMPACT F WNG N
TOP N
COMPACT F 7/9/12/18
RC3 Remote control
OU 7/9/12 RC
OU NG 18
Accessories
Mounting bracket
18
• Part number
COMPACT F7
7ACTL0016
COMPACT F9
7ACTL0016
COMPACT F12
7ACTL0016
COMPACT F18
7ACTL0018
EUROPE
AMBIANCE
electra 2008 Air conditioning & Heating CATALOGUE
4 Heat Pump models R410A: from 2 310 to 5 000 W
COMPACT F 7
COMPACT F 9
2.32
0.72
3.2/A
2.76
0.84
3.29/A
3.6
1.12
3.21/A
v10/46 ° Dry Bulbk
5
1.66
3.01/B
2.31
0.68
3.41/B
3.07
0.9
3.43/B
3.84
1.12
3.43/B
v-9 °/24 ° Dry Bulbk
5
1.62
3.09/D
dB(A)
dB(A)
m3/h
l/h
mm
kg
31/37
45/50
320/400
0.7
680x180x250
7
ESP022408
35/40
48/52
350/450
1.2
680x180x250
7
ESP022409
33/40
47/53
460/620
1.5
840x180x250
8
ESP022410
35/44
45/55
450/670
2
900x200x295
15
ESP022411
dB(A)
dB(A)
m3/h
53
62
1200
Rotary
27.5
610x240x520
ESP061568
51
61
1370
Rotary
33.5
830x245x545
ESP061569
54
65
1450
Rotary
38
830x245x545
ESP061570
54
65
2160
Rotary
43
795x290x610
ESP061571
Linking specifications between indoor and outdoor units
Power supply 1~230 V
Power supply side
Indoor
Power cable section
mm2
3x1.5
Fuse rating am
A
10
Electrical connections
mm2
4x1
5x1
Electrical connections
mm2
Indoor
3x1.5
10
4x1
5x1
Indoor
3x1.5
16
4x1.5
5x1.5
Indoor
3x1.5
16
4x1.5
5x1.5
Linking pipes
Max. lenght
Max. height
Suction pipe diameter
Liquid pipe diameter
12
7
3/8”
1/4”
15
7
1/2”
1/4”
15
7
1/2”
1/4”
Cooling Capacity
Power Input
EER/Energy Label
Out. temperature operating limits
kW
kW
Heating Capacity
Power Input
COP/Energy Label
Out. temperature operating limits
kW
kW
Indoor units
Sound pressure level to 1 m (LS/HS)
Sound power level
Airflow (LS/HS)
Dehumidification
Dimensions (WxDxH)
Weight
• Part number
Outdoor units
Sound pressure level to 1 m
Sound power level
Airflow
Compressor type
Weight
Dimensions (WxDxH)
• Part number
°C
°C
kg
mm
m
m
Inches
Inches
10
7
3/8”
1/4”
COMPACT F 12
COMPACT F 18
WORLD
ARMOIRES
COMPACT SERIES
19
WNG N
Wall mounted
Product benefits
R410A «green» fluid.
High efficiency filtration, 3 nivels of filters : Standard; Electrostatic; Active charcoal.
● Ioniser.
● Functions
displayed on LCD display (except for WNG 24 NRC LED model).
● Electronic
regulation and programming.
● Automatic
vertical treated air sweeping.
● Airconet compatible system (for WNG 30).
●
●
Wall monted range
: Platinium DC INV Delta DC INV
: COMPACT F WNG N
Top
WNG N 30/36
WNG N 24
RC3 Remote control
Outdoor unit
Accessories
Mounting bracket
Condensate lift pump
All seasons kit
• Part number
• Part number
• Part number
WNG N 24 RC
SAE3100
7ACFH0480
WNG N 30 RC
SAE3100
7ACFH0480
Important : installation of an all seasons kit only allows for operation in cooling mode.
20
EUROPE
AMBIANCE
electra 2008 Air conditioning & Heating CATALOGUE
3 Heat Pump models R410A : from 7 080 to 11 140 W
WNG N SERIES
WNG N24 RC
WNG N30 RC
WNG N36 RC
Cooling Capacity
kW
Power Input
kW
EER/Energy Label
Out. temperature operating limits °C
6.77
2.24
3.0/B
8.50
2.90
2.9/C
10.15
3.22
3.15/B
Heating Capacity
Heating Capacity at -10 °C Out.
Power Input
COP/Energy Label
Out. temperature operating limits
7.08
3.93
2.4
3.0/D
°C
Indoor units
Air flow (LS/NS/HS)
m3/h
Acoustic pressure to 1 m (LS/HS) dB(A)
Dehumidification
l/h
Weight
kg
Dimensions (WxDxH)
mm
• Part number (model with AQS)
Outdoor units
Air flow
Acoustic pressure to 1 m
Compressor type
Weight
Dimensions (WxDxH)
• Part number 1~230 V
• Part number 3N~400 V
9.08
4.68
2.90
3.0/D
11.14
5.76
3.6
3.1/D
v-9 °/24 ° Dry Bulbk
740/820/910
42/44/47
2.3
15
1060x210x295
ESP022272
m3/h 3100
dB(A) 54
Rotary
kg
74
mm 900x340x650
ESP061680
ESP061655
1030/1100/1360
44/48/52
3.6
17
1200x236x340
ESP022269
1110/1240/1360
48/50/52
4
17
1200x236x340
ESP022328
3150
58
Rotary
78
900x340x860
ESP061587
ESP061588
4150
59
Rotary
87
900x340x970
ESP061612
ESP061613
Linking specifications between indoor
and outdoor units
Power supply 1~230 V
Power supply side
Power cable section
mm2
Fuse rating am
A
Electrical connections Ind./Out. mm
Ind. or Out.
3x2.5
20
6x1.5
Outdoor
3x4
25
6x1.5
Outdoor
3x4
25
6x1.5
Power supply 3N~400 V
Power supply side
Power cable section
Fuse rating am
Electrical connections Ind./Out.
mm2
A
mm
Ind. or Out.
5x1.5
3x10
6x1.5
Outdoor
5x2.5
3x16
6x1.5
Outdoor
5x2.5
3x16
6x1.5
Linking pipes
Max. lenght
Max. height
Suction pipe diameter
Liquid pipe diameter
m
m
Inches
Inches
20
15
5/8”
3/8”
30
10
5/8”
3/8”
50
25
3/4”
3/8”
WORLD
ARMOIRES
kW
kW
kW
v21 °/46 ° Dry Bulbk
* In the case of connections to an indoor unit.
21
Wall mounted
TOP
Product benefits
Low or high wall mounted installation.
Innovative and ultra-compact design (14 cm deep only).
● High
performance filtration.
● Electronic
regulation and programming.
● Treated
air distribution from all 4 sides.
● Ultra-quiet
operation – Only 31 dBA at 1 m.
● Condensate
drainage lift pump (accessory).
● Airconet
compatible system.
●
●
Wall monted range
: Platinium DC INV Delta DC INV
: COMPACT F WNG N
Top
TOP 9/12 RC
OUNG 9/12 RC
RC6 Remote control
RCW2 Remote control (accessory)
• Part number 7ACEL1212
22
EUROPE
AMBIANCE
electra 2008 Air conditioning & Heating CATALOGUE
2 Heat Pump models R410A : from 2 850 to 3 690 W
Cooling Capacity
Power Input
EER/Energy Label
Out. temperature operating limits
Heating Capacity
Power Input
COP/Energy Label
Indoor units
Air flow (LS/NS/HS)
Acoustic pressure to 1 m (LS/HS)
Weight
Dimensions (WxDxH)
• Part number
Outdoor units
Acoustic pressure to 1 m
Compressor type
Net weight
Dimensions (WxDxH)
• Part number
kW
kW
TOP 9 RC
TOP 12 RC
2.59
0.8
3.22/A
3.3
1.09
3.03/B
°C
v21 °/46 ° Dry Bulbk
kW
kW
2.85
0.83
3.43/B
3.69
1.21
3.05/D
m3/h
dB(A)
kg
mm
330/360/390
31/33/35
13.5
570x160x570
ESP022340
310/360/430
32/35/39
14
570x160x570
ESP022341
dB(A)
53
Rotary
35
745x290x610
ESP061641
51
Rotary
36
745x290x610
ESP061642
Indoor
3x1.5
10
4x1.5
5x1.5
Indoor
3x1.5
10
4x1.5
5x1.5
15
7
3/8”
1/4”
15
7
3/8”
1/4”
kg
mm
Linking specifications between indoor and outdoor units
Power supply 1~230 V
Power supply side
Power cable section
mm2
Fuse rating am
A
Electrical connections
mm2
Electrical connections
mm3
Linking pipes
Max. lenght
m
Max. height difference
m
Suction pipe diameter
Inches
Liquid pipe diameter
Inches
* In the case of connections to an indoor unit.
WORLD
ARMOIRES
TOP SERIES
23
CN DC
Cassettes
INVERTER
Product benefits
Four motorized air distribution flaps.
New air intake.
● Air
distribution to an adjacent room.
● High
efficiency filtration.
● Designed
for integration in suspended ceilings.
● Simplified
installation and maintenance.
● 600
x 600 mm format / Built-in depth: 270 mm
● Integrated
condensate drainage lift pump.
● Optimal
efficiency Class A energy label (depending on models).
● Electronic
regulation and programming.
● Compatible
with DUO, TRIO and QUATTRO DCI Multisplits.
● Up
to 50 m pipe length between indoor and outdoor unit.
● Up
to 25 m vertical high between indoor and outdoor unit.
●
●
Cassettes range
: CN DCI
ECF/ECF XLDCI
: ECF N/ ECF XLN
OU 9/12/18 DCI
CN DCI
RC3 Remote control
Accessories
Mounting bracket
Remote control RCW2
24
• Part number
• Part number
CN 9 DCI
7ACTL0016
7ACEL1212
RCW2 Remote control (accessory)
• Part number 7ACEL1212
CN 12 DCI
7ACTL0016
7ACEL1212
CN 18 DCI
7ACTL0016
7ACEL1212
CN 24 DCI
7ACEL1212
electra 2008 Air conditioning & Heating CATALOGUE
Programming
• Controlling up to 15 zones (32 units)
with individual unit time programming
and temperature setting functions.
• 7 day programmable thermostat with
2 daily setting ranges.
basic functions
RCW2 model
Multi-functions remote controls
at the forefront of ergonomic design
• Heating/Cooling electronic regulation.
• Automatic fan ventilation or 3 fixed speeds
fan ventilation.
• Night time slow running.
• Dehumidification.
centralised control
• Easy functions duplication for quick
programming.
• “Master/Slave” function.
• Time delayed start up of air treatment units
(multiple unit installations).
• Permanent “I feel” function (single unit
installations).
9
Airconet
Remote management of your air conditioning network
Airconet is a complete, powerful and user-friendly system providing remote management of air conditioning
installations in an overall and customised manner :
• Centralised control of a group of indoor units (building, floor…).
• Individual control in each pre-defined room and zone.
Irrespective of the type of building, by way of a simple PC connected to the Internet or to the building's local
network, Airconet provides total control of a complete air conditioning system.
In fact, from the Airconet communication gateway connected to each of the indoor units and depending on
access rights granted, the user can regulate blown air temperatures and fan speeds and even receive e-mail
or SMS alerts regarding any system malfunctions…
Installation architecture
LAN/WEB
SMS
Managed site
Basic configuration : 1 Airconet communication gateway module Å per site capable of managing up to 247 indoor units, 1 MIU Ç per indoor unit
depending on the unit type.
NB. Each distributor needs to have 1 converter (SP000000080) Ñ to loan out to installers. This converter is required for initial installation configuration.
10
electra 2007 air conditioning catalogue
Advantages :
Benefits :
• User-friendly, straightforward,
• Improved occupant comfort (e.g.
efficient and autonomous interface.
timing a unit to start operating before
• Plug and Play installation,
the arrival of the client/occupant).
no software installation, modem
• Lower energy bills by way of
integrated in the communication
energy savings derived from overall
Gateway.
installation control, and therefore
• Integrated system supervision,
close control of energy consumption.
easy to use.
• Simplified management and
• Choice of languages.
improved maintenance thanks
• Perfect compatibility with
to optimal installation control
Windows operating systems :
and real time interventions.
XP, 2000, NT, 98…
• Extended equipment service life.
• Up to 247 units managed by
• Completely upgradeable system.
a single communication Gateway.
• Real time alerts by e-mail or SMS
• Very low investment.
of any installation malfunction.
Principle :
The heart of the system is the Airconet communication
gateway. This is a module installed on site and connected,
on the one hand to all the air conditioning units to be
managed by way of an MIU (Modbus Interface Unit) and,
on the other hand, to a LAN/WEB network. In this manner,
the user can connect to the communication gateway via a
PC with an internet connection. Thanks to the Plug & Play
system there is no requirement for the user to install any
special software as this is already loaded in the Airconet
communication gateway. Via the PC’s internet navigator,
it is possible to set and alter parameters such as room
temperatures and timer programming as well as to be
alerted in the event of any possible malfunctions.
Several user levels
Level
1
2
3
4
5
User
Possibilities
Company employee
Reception manager (hotels…)
Maintenance manager
Technician
Supervisor/Developer
Local normal control of an individual unit
Centralised normal control of all units
Communication gateway information verification
System definition
Database and parameters
CUSTOMER
SERVICE
Communication gateway Å
Range
Size
Part number
Managed with all indoor units
Managed with all sizes
AIRCONET006
MIU - Communication cards Ç
Range
DC Inverter
R410A
R407C/R22
Model
Size
Part number
CK DCI
PXD DCI
LSN DCI
ECF DCI
WNG N
TOP
PXD N
ECF N
ECF XL N
DNG
9/12/18/21/24
9/12/18/24/28
9/12/18/24
9/12/18
30
9/12
9/12/15/18/24/30
9/11/15/18
24/30/36/45
18/24/30/37/44
Please, consult us
Please, consult us
Please, consult us
Please, consult us
Please, consult us
Please, consult us
Please, consult us
Please, consult us
Please, consult us
Please, consult us
CCE 45
all sizes
NOTE 1 : Each “Airconet XXX” reference includes the communication board (MIU) as well as the connections required for connecting to the unit.
NOTE 2 : In addition to 40 MIU boards connected to the communication gateway, a REPEATER (free of charge supply) must be installed.
11
DCI - R410A - R407C range
EUROPE range
12
EUROPE
AMBIANCE
electra 2007 air conditioning catalogue
DELTA DCI
PLATINIUM DCI
COMPACT F
WNG N
TOP N
CASSETTES
CN DCI
ECF / ECF XL DCI
ECFN / ECF XL N
dUCTED
14
16
18
20
22
24
26
28
FLOOR / CEILING
PXD DCI
PXD N / NSA
30
32
34
36
38
LS DCI
DNG DCI
LS / DNG
MOBILE / MONOBLOC
40
41
SMILY / N
JKF
WINDOWS-COLUMN
42
43
AWD
CCE
MULTISPLITS
44
46
48
DUO/TRIO/QUATTRO DCI
DUO/TRIO DELTA
DUO R410A
13
WORLD
ARMOIRES
wall mounted
Wall mounted
DELTA DC
INVERTER
Product benefits
Flexibility and comfort of use.
Extended operating range.
● Optimal
efficiency : Class A energy label (depending on models).
● Reduced
noise levels.
● High
efficiency filtration.
● Electronic
regulation and programming.
● Automatic
treated air sweeping.
● R410A
«green» fluid.
● Optimal
temperature regulation.
● Heating
mode operation down to outdoor temperatures of -15 °C.
●
●
Wall monted range
: Platinium DC INV Delta DC INV
: Compact F WNG N
Top
DELTA 7/9 DCI
RC7 Remote control
DELTA 12/18 DCI
OU 7/9/12 DCI
OU 18 DCI
Accessories
Mounting bracket
Condensate lift pump
14
• Part number
• Part number
DELTA 7 DC INV
7ACTL0016
SAE3100
DELTA 9 DC INV
7ACTL0016
SAE3100
DELTA 12 DC INV
7ACTL0016
SAE3100
DELTA 18 DC INV
7ACTL0016
SAE3100
EUROPE
AMBIANCE
electra 2008 Air conditioning & Heating CATALOGUE
4 Heat Pump models DCI : from 2 500 to 5 300 W
DELTA 7 DCI
DELTA 9 DCI
2.2
0.66
3.33/A
2.5
0.75
3.33/A
3.5
1.03
3.39/A
v-10 °/46 ° Dry Bulbk
5
1.56
3.2/B
2.5
0.73
3.42/B
2.8
0.82
3.41/B
3.6
1.05
3.42/B
v-15 °/24 ° Dry Bulbk
5.3
1.55
3.41/B
m3/h
dB(A)
l/h
kg
mm
300/350/400
30/33/36
1
7
680x185x250
ESP022275
270/350/420
32/35/39
1
7
680x185x250
ESP022276
350/450/550
29/33/39
1.5
8
840x185x250
ESP022277
480/620/720
34/41/44
2
11
900x205x295
ESP022278
m3/h
dB(A)
1400
54
Rotary DC Inverter
35
760x245x545
ESP061601
1390
54
Rotary DC Inverter
36
830x245x545
ESP061602
1390
55
Rotary DC Inverter
37
830x245x545
ESP061603
2160
53
Scroll DC Inverter
38
795x290x610
ESP061597
Linking specifications between indoor and outdoor units
Power supply
Power supply side
Indoor
Power cable section
mm2 3x1.5
Fuse rating am
A
12
Electrical connections
mm2 4x1.5
Indoor
3x1.5
12
4x1.5
Indoor
3x1.5
16
4x1.5
Indoor
3x1.5
20
5x1.5
Linking pipes
Max. lenght
Max. height
Suction pipe diameter
Liquid pipe diameter
15
10
3/8”
1/4”
15
10
3/8”
1/4”
15
10
1/2”
1/4”
Cooling Capacity
Power Input
EER/Energy Label
Outdoor temperature operating limits
kW
kW
Heating Capacity
Power Input
COP/Energy Label
Outdoor temperature operating limits
kW
kW
Indoor Units
Air flow (LS/NS/HS)
Acoustic pressure to 1 m (LS/NS/HS)
Dehumidification
Weight
Dimensions (WxDxH)
• Part number 1~230 V
Outdoor Units
Air flow
Acoustic pressure to 1 m
Compressor type
Weight
Dimensions (WxDxH)
• Part number 1~230 V
°C
°C
kg
mm
m
m
Inches
Inches
15
10
3/8”
1/4”
DELTA 12 DCI
DELTA 18 DCI
15
WORLD
ARMOIRES
DELTA DC INVERTER SERIES
Wall mounted
PLATINIUM DC INVERTER
Product benefits
Perfect comfort, unequalled unobtrusiveness, great accuracy
in maintaining the desired temperature and controlling air quality.
● R410A
«green» fluid.
● Optimal
efficiency : Class A energy label (depending on models).
● Heating
mode operation down to outdoor temperatures of -15 °C.
● Optimal
temperature regulation.
● Electronic
regulation and programming.
● AQS
filtration : electrostatic filter + Ioniser.
● Automatic
treated air sweeping.
● LCD
screen.
● Fluid
pre-charged at the factory for up to 20 m pipe lengths
(depending on models).
● Compatible
with AIRCONET regulation (PLATINIUM 18 DCI).
●
Wall monted range
: Platinium DC INV Delta DC INV
: Compact F WNG N
Top
PLATINIUM 21 DCI
RC3 Remote control
OU PLATINIUM 18 DCI
Accessories
Condensate lift pump
16
PLATINIUM 25/28 DCI
• Part number
PLATINIUM 21
DC INV
SAE3100
OU PLATINIUM 25/28 DCI
PLATINIUM 25
DC INV
SAE3100
PLATINIUM 28
DC INV
SAE3100
EUROPE
AMBIANCE
electra 2008 Air conditioning & Heating CATALOGUE
3 Heat Pump models DCI : from 6500 to 8 500 W
PLATINIUM DC INVERTER
SERIES
PLATINIUM 25 DCI
PLATINIUM 28 DCI
6 (1.5-6.7)
1.99
3.01/B
6.8 (1.5-7.5)
2.25
3.0/B
v-10 °/46 ° Dry Bulbk
7.8 (1.5-8.8)
2.59
3.0/B
6.5 (1.8-7.9)
1.90
3.42/B
7.0 (1.5-8.8)
2.19
3.2/C
v-15 °/24 ° Dry Bulbk
8.5 (1.5-9.5)
2.65
3.2/C
m3/h
dB(A)
l/h
kg
mm
620/760/900
34/45
2
15
1060x210x295
ESP022280
700/850/1000
38/47
2.5
15
1060x210x295
ESP022282
950/1100/1250
44/51
3
18.5
1200x236x340
ESP022284
m3/h
dB(A)
2860
55
Scroll DC Inverter
46
846x302x690
ESP061598
3600
56
Twin Rotary DC Inverter
64.5
950x412x835
ESP061599
3600
56
Twin Rotary DC Inverter
66
950x412x835
ESP061600
Linking specifications between indoor and outdoor units
Power supply
Power supply side
Indoor
Power cable section
mm2 3x2.5
Fuse rating am
A
20
Electrical connections
mm2 4x2.5
Outdoor
3x2.5
20
4x2.5
Outdoor
3x2.5
20
4x2.5
Linking pipes
Max. lenght
Max. height
Suction pipe diameter
Liquid pipe diameter
30
15
5/8”
3/8”
30
15
5/8”
3/8”
Cooling Capacity
Power Input
EER/Energy Label
Outdoor temperature operating limits
kW
kW
Heating Capacity
Heating Capacity at -15 °C
Power Input
COP/Energy Label
Outdoor temperature operating limits
kW
kW
kW
Indoor Units
Air flow (LS/NS/HS)
Acoustic pressure to 1 m (LS/HS)
Dehumidification
Weight
Dimensions (WxDxH)
• Part number 1~230 V
Outdoor Units
Air flow
Acoustic pressure to 1 m
Compressor type
Weight
Dimensions (WxDxH)
• Part number 1~230 V
°C
°C
kg
mm
m
m
Inches
Inches
30
10
1/2”
1/4”
WORLD
ARMOIRES
PLATINIUM 21 DCI
17
COMPACT F
Wall mounted
(R410A)
Product benefits
New design with flat panet grill.
Compact and lightweight for easy installation and maintenance.
●2
ventilation speed plus automatic speed.
● Cold/hot
Automatic regulation.
● Automatic
vertical treated air sweeping.
● High
efficiency filtration.
● COMPACT
9 & 12 (available with class C on request).
●
●
Wall monted range
: Delta DCI
Platinium DCI
: COMPACT F WNG N
TOP N
COMPACT F 7/9/12/18
RC3 Remote control
OU 7/9/12 RC
OU NG 18
Accessories
Mounting bracket
18
• Part number
COMPACT F7
7ACTL0016
COMPACT F9
7ACTL0016
COMPACT F12
7ACTL0016
COMPACT F18
7ACTL0018
EUROPE
AMBIANCE
electra 2008 Air conditioning & Heating CATALOGUE
4 Heat Pump models R410A: from 2 310 to 5 000 W
COMPACT F 7
COMPACT F 9
2.32
0.72
3.2/A
2.76
0.84
3.29/A
3.6
1.12
3.21/A
v10/46 ° Dry Bulbk
5
1.66
3.01/B
2.31
0.68
3.41/B
3.07
0.9
3.43/B
3.84
1.12
3.43/B
v-9 °/24 ° Dry Bulbk
5
1.62
3.09/D
dB(A)
dB(A)
m3/h
l/h
mm
kg
31/37
45/50
320/400
0.7
680x180x250
7
ESP022408
35/40
48/52
350/450
1.2
680x180x250
7
ESP022409
33/40
47/53
460/620
1.5
840x180x250
8
ESP022410
35/44
45/55
450/670
2
900x200x295
15
ESP022411
dB(A)
dB(A)
m3/h
53
62
1200
Rotary
27.5
610x240x520
ESP061568
51
61
1370
Rotary
33.5
830x245x545
ESP061569
54
65
1450
Rotary
38
830x245x545
ESP061570
54
65
2160
Rotary
43
795x290x610
ESP061571
Linking specifications between indoor and outdoor units
Power supply 1~230 V
Power supply side
Indoor
Power cable section
mm2
3x1.5
Fuse rating am
A
10
Electrical connections
mm2
4x1
5x1
Electrical connections
mm2
Indoor
3x1.5
10
4x1
5x1
Indoor
3x1.5
16
4x1.5
5x1.5
Indoor
3x1.5
16
4x1.5
5x1.5
Linking pipes
Max. lenght
Max. height
Suction pipe diameter
Liquid pipe diameter
12
7
3/8”
1/4”
15
7
1/2”
1/4”
15
7
1/2”
1/4”
Cooling Capacity
Power Input
EER/Energy Label
Out. temperature operating limits
kW
kW
Heating Capacity
Power Input
COP/Energy Label
Out. temperature operating limits
kW
kW
Indoor units
Sound pressure level to 1 m (LS/HS)
Sound power level
Airflow (LS/HS)
Dehumidification
Dimensions (WxDxH)
Weight
• Part number
Outdoor units
Sound pressure level to 1 m
Sound power level
Airflow
Compressor type
Weight
Dimensions (WxDxH)
• Part number
°C
°C
kg
mm
m
m
Inches
Inches
10
7
3/8”
1/4”
COMPACT F 12
COMPACT F 18
WORLD
ARMOIRES
COMPACT SERIES
19
WNG N
Wall mounted
Product benefits
R410A «green» fluid.
High efficiency filtration, 3 nivels of filters : Standard; Electrostatic; Active charcoal.
● Ioniser.
● Functions
displayed on LCD display (except for WNG 24 NRC LED model).
● Electronic
regulation and programming.
● Automatic
vertical treated air sweeping.
● Airconet compatible system (for WNG 30).
●
●
Wall monted range
: Platinium DC INV Delta DC INV
: COMPACT F WNG N
Top
WNG N 30/36
WNG N 24
RC3 Remote control
Outdoor unit
Accessories
Mounting bracket
Condensate lift pump
All seasons kit
• Part number
• Part number
• Part number
WNG N 24 RC
SAE3100
7ACFH0480
WNG N 30 RC
SAE3100
7ACFH0480
Important : installation of an all seasons kit only allows for operation in cooling mode.
20
EUROPE
AMBIANCE
electra 2008 Air conditioning & Heating CATALOGUE
3 Heat Pump models R410A : from 7 080 to 11 140 W
WNG N SERIES
WNG N24 RC
WNG N30 RC
WNG N36 RC
Cooling Capacity
kW
Power Input
kW
EER/Energy Label
Out. temperature operating limits °C
6.77
2.24
3.0/B
8.50
2.90
2.9/C
10.15
3.22
3.15/B
Heating Capacity
Heating Capacity at -10 °C Out.
Power Input
COP/Energy Label
Out. temperature operating limits
7.08
3.93
2.4
3.0/D
°C
Indoor units
Air flow (LS/NS/HS)
m3/h
Acoustic pressure to 1 m (LS/HS) dB(A)
Dehumidification
l/h
Weight
kg
Dimensions (WxDxH)
mm
• Part number (model with AQS)
Outdoor units
Air flow
Acoustic pressure to 1 m
Compressor type
Weight
Dimensions (WxDxH)
• Part number 1~230 V
• Part number 3N~400 V
9.08
4.68
2.90
3.0/D
11.14
5.76
3.6
3.1/D
v-9 °/24 ° Dry Bulbk
740/820/910
42/44/47
2.3
15
1060x210x295
ESP022272
m3/h 3100
dB(A) 54
Rotary
kg
74
mm 900x340x650
ESP061680
ESP061655
1030/1100/1360
44/48/52
3.6
17
1200x236x340
ESP022269
1110/1240/1360
48/50/52
4
17
1200x236x340
ESP022328
3150
58
Rotary
78
900x340x860
ESP061587
ESP061588
4150
59
Rotary
87
900x340x970
ESP061612
ESP061613
Linking specifications between indoor
and outdoor units
Power supply 1~230 V
Power supply side
Power cable section
mm2
Fuse rating am
A
Electrical connections Ind./Out. mm
Ind. or Out.
3x2.5
20
6x1.5
Outdoor
3x4
25
6x1.5
Outdoor
3x4
25
6x1.5
Power supply 3N~400 V
Power supply side
Power cable section
Fuse rating am
Electrical connections Ind./Out.
mm2
A
mm
Ind. or Out.
5x1.5
3x10
6x1.5
Outdoor
5x2.5
3x16
6x1.5
Outdoor
5x2.5
3x16
6x1.5
Linking pipes
Max. lenght
Max. height
Suction pipe diameter
Liquid pipe diameter
m
m
Inches
Inches
20
15
5/8”
3/8”
30
10
5/8”
3/8”
50
25
3/4”
3/8”
WORLD
ARMOIRES
kW
kW
kW
v21 °/46 ° Dry Bulbk
* In the case of connections to an indoor unit.
21
Wall mounted
TOP
Product benefits
Low or high wall mounted installation.
Innovative and ultra-compact design (14 cm deep only).
● High
performance filtration.
● Electronic
regulation and programming.
● Treated
air distribution from all 4 sides.
● Ultra-quiet
operation – Only 31 dBA at 1 m.
● Condensate
drainage lift pump (accessory).
● Airconet
compatible system.
●
●
Wall monted range
: Platinium DC INV Delta DC INV
: COMPACT F WNG N
Top
TOP 9/12 RC
OUNG 9/12 RC
RC6 Remote control
RCW2 Remote control (accessory)
• Part number 7ACEL1212
22
EUROPE
AMBIANCE
electra 2008 Air conditioning & Heating CATALOGUE
2 Heat Pump models R410A : from 2 850 to 3 690 W
Cooling Capacity
Power Input
EER/Energy Label
Out. temperature operating limits
Heating Capacity
Power Input
COP/Energy Label
Indoor units
Air flow (LS/NS/HS)
Acoustic pressure to 1 m (LS/HS)
Weight
Dimensions (WxDxH)
• Part number
Outdoor units
Acoustic pressure to 1 m
Compressor type
Net weight
Dimensions (WxDxH)
• Part number
kW
kW
TOP 9 RC
TOP 12 RC
2.59
0.8
3.22/A
3.3
1.09
3.03/B
°C
v21 °/46 ° Dry Bulbk
kW
kW
2.85
0.83
3.43/B
3.69
1.21
3.05/D
m3/h
dB(A)
kg
mm
330/360/390
31/33/35
13.5
570x160x570
ESP022340
310/360/430
32/35/39
14
570x160x570
ESP022341
dB(A)
53
Rotary
35
745x290x610
ESP061641
51
Rotary
36
745x290x610
ESP061642
Indoor
3x1.5
10
4x1.5
5x1.5
Indoor
3x1.5
10
4x1.5
5x1.5
15
7
3/8”
1/4”
15
7
3/8”
1/4”
kg
mm
Linking specifications between indoor and outdoor units
Power supply 1~230 V
Power supply side
Power cable section
mm2
Fuse rating am
A
Electrical connections
mm2
Electrical connections
mm3
Linking pipes
Max. lenght
m
Max. height difference
m
Suction pipe diameter
Inches
Liquid pipe diameter
Inches
* In the case of connections to an indoor unit.
WORLD
ARMOIRES
TOP SERIES
23
CN DC
Cassettes
INVERTER
Product benefits
Four motorized air distribution flaps.
New air intake.
● Air
distribution to an adjacent room.
● High
efficiency filtration.
● Designed
for integration in suspended ceilings.
● Simplified
installation and maintenance.
● 600
x 600 mm format / Built-in depth: 270 mm
● Integrated
condensate drainage lift pump.
● Optimal
efficiency Class A energy label (depending on models).
● Electronic
regulation and programming.
● Compatible
with DUO, TRIO and QUATTRO DCI Multisplits.
● Up
to 50 m pipe length between indoor and outdoor unit.
● Up
to 25 m vertical high between indoor and outdoor unit.
●
●
Cassettes range
: CN DCI
ECF/ECF XLDCI
: ECF N/ ECF XLN
OU 9/12/18 DCI
CN DCI
RC3 Remote control
Accessories
Mounting bracket
Remote control RCW2
24
• Part number
• Part number
CN 9 DCI
7ACTL0016
7ACEL1212
RCW2 Remote control (accessory)
• Part number 7ACEL1212
CN 12 DCI
7ACTL0016
7ACEL1212
CN 18 DCI
7ACTL0016
7ACEL1212
CN 24 DCI
7ACEL1212
EUROPE
AMBIANCE
electra 2008 air conditioning & heating catalogue
4 Heat Pump models DCI: from 3 200 to 7 300 W
CN 9 DCI
CN 12 DCI
2,5 (0,9-3,4)
0,63
4/A
3,5 (0,9-4,0)
5 (1,55-6,4)
1,01
1,55
3,45/A
3,22/A
v-10°/46° Dry bulb k
6,8 (1,5-7,5)
2,25
3/B
3,2 (0,9-4,2)
0.8
4/A
4,2 (0,9-4,8)
5,8 (1-7)
1.16
1.6
3.62/A
3.62/A
v-15 °/24 ° Dry Bulb k
7,3 (1,5-8,4)
2.27
3.22/C
dB(A)
dB(A)
m3/h
l/h
mm
mm
mm
kg
29/35
46
460
0,76
575x575x219
625x625x40
725x725x40
16
ESP022401
7ACVF0478
7ACVF0479
29/35
46
460
1,45
575x575x219
625x625x40
725x725x40
16
ESP022402
7ACVF0479
7ACVF0479
36/42
53
780
1,74
575x575x270
625x625x40
725x725x40
16
ESP022403
7ACVF0480
7ACVF0479
42/48
59
1010
2,62
575x575x270
625x625x40
725x725x40
19
ESP022405
7ACVF0481
7ACVF0479
dB(A)
dB(A)
m3/h
kg
mm
kg
51
60
1780
Rotary DC Inverter
795x290x610
38
ESP061483
52
62
1780
Rotary DC Inverter
795x290x610
38
ESP061484
52
62
2160
Rotary DC Inverter
795x290x610
39
ESP061604
55
65
3600
Twin Rotary DC Inverter
950x412x835
65
ESP061676
Linking specifications between indoor and outdoor units
Power supply 1-230V
Power supply side
Power cable section
mm2
Fuse rating am
A
Electrical connections
mm2
Indoor
3x1.5
16
4x1.5
Indoor
3x1.5
16
4x1.5
Indoor
3x2.5
20
4x2.5
Indoor
3x2.5
20
4x2.5
Linking pipes
Max. lenght
Max. height
Suction pipe diameter
Liquid pipe diameter
25
10
3/8”
1/4”
25
10
3/8”
1/4”
30
10
1/2”
1/4”
50
25
5/8”
3/8”
Cooling Capacity
Power Input
EER/Energy Label
Outdoor temperature operating limits
kW
kW
Heating Capacity
Power Input
COP/Energy Label
Outdoor temperature operating limits
kW
kW
Indoor Units
Sound pressure level to 1 m
Sound power level
Airflow
Dehumidification
Dimensions (WxDxH)
Frame for grid ceiling (WxDxH)
Frame for hard ceiling (WxDxH)
Weight
• Part number
• Part number Frame for grid ceiling
• Part number Frame for hard ceiling
Outdoor Units
Sound pressure level to 1 m
Sound power level
Airflow
Compressor type
Dimensions (WxDxH)
Weight
• Part number 1~230 V
°C
°C
m
m
Inches
Inches
CN 18 DCI
CN 30 DCI
25
WORLD
ARMOIRES
CN DCI DC INVERTER SERIES
Cassettes
ECF & ECF XL DC
INVERTER
Product benefits
Perfect comfort, unequalled unobtrusiveness, great accuracy
in maintaining the desired temperature and controlling air quality.
● Four
powered air distribution flaps.
● Designed
for integration in suspended ceilings.
● 600x600
mm format (ECF DCI) / 900x900 mm format (ECFXL DCI).
● Built-in
depth : 287 mm (ECF DCI) / 230 mm (ECFXL DCI).
● R410A
«green» fluid.
● Optimal
efficiency : Class A energy label (depending on models).
● Heating
mode operation down to outdoor temperatures of -15 °C.
● Optimal
temperature regulation.
● Electronic
regulation and programming.
● Fluid
pre-charged at the factory for up to 20 m pipe lengths
(depending on models).
● Possibility
of air conditioning two separate rooms with a single unit.
● New
air intake.
● High
efficiency filtration.
● Integrated
condensate drainage lift pump.
● Solid
ceiling mounting frame (accessory).
● Compatible with AIRCONET regulation.
●
Cassettes range
: ECF/ECF XL DC INV
Air renewal
Air conditioning of an adjacent room
adjacent room
main room
RC3 Remote control
OU 24/30 DCI
OU 9/12/18 DCI
inside
outside
ECFXL 24/30 DCI
ECF 9/12/18 DCI
: ECF N/ECF XLN
RCW2 Remote control (accessory)
• Part number 7ACEL1212
Accessories
Ceiling adapter frame
Mounting bracket
26
• Part number
• Part number
ECF 9 DCI
7ACVF0091
7ACTL0016
ECF 12 DCI
7ACVF0091
7ACTL0016
ECF 18 DCI
7ACVF0091
7ACTL0016
EUROPE
AMBIANCE
electra 2008 air conditioning & heating catalogue
ECF/ECFXL DC INVERTER SERIES
ECFXL 24 DCI
ECFXL 30 DCI
3.5 (1.5-4.4)
5 (1.4-6.4)
0.95
1.55
3.7/A
3.2/A
v-10 °/46 ° Dry Bulbk
7.2 (1.5-8)
2.39
3.0/B
8 (1.5-8.8)
2.65
3.0/B
3.4 (1.5-5)
2
0.91
3.7/A
4.3 (1.5-5.5)
6.3 (1.35-7.5)
2.6
2.3
1.33
1.74
3.2/C
3.6/A
v-15 °/24 ° Dry Bulbk
8 (1.5-8.8)
2.22
3.6/A
9 (1.5-10)
2.48
3.6/A
m3/h
dB(A)
l/h
kg
mm
mm
450/530/600
32/37
1
23
571x571x287
625x625x40
Included
ESP042116
450/560/620
32/37
1.5
24
571x571x287
625x625x40
Included
ESP042117
510/630/730
36/48
2
28
571x571x287
625x625x40
Included
ESP042118
1050/1200/1300
47/52
2.5
36
840x840x230
950x950x46
EACVF0002
ESP012155
1070/1170/1270
42/46
3
48
840x840x300
950x950x46
EACVF0002
ESP012160
m3/h
dB(A)
1780
50
Rotary DC Inverter
38
795x290x610
ESP061483
1780
52
Rotary DC Inverter
38
795x290x610
ESP061484
2160
53
Scroll DC Inverter
39
795x290x610
ESP061604
3600
3600
55
56
Twin Rotary DC Inverter Twin Rotary DC Inverter
64.5
66
950x412x835
950x412x835
ESP061676
ESP061600
Linking specifications between indoor and outdoor units
Power supply
Power supply side
Indoor
Power cable section
mm2
3x1.5
Fuse rating am
A
16
Electrical connections
mm2
4x1.5
Indoor
3x1.5
16
4x1.5
Indoor
3x2.5
20
4x2.5
Indoor
3x2.5
20
4x2.5
Indoor
3x2.5
20
4x2.5
Linking pipes
Max. lenght
Max. height
Suction pipe diameter
Liquid pipe diameter
20
10
3/8”
1/4”
30
10
1/2”
1/4”
30
15
5/8”
3/8”
30
15
5/8”
3/8”
Cooling Capacity
Power Input
EER/Energy Label
Outdoor temperature operating limits
kW
kW
Heating Capacity
Heating Capacity at -15 °C
Power Input
COP/Energy Label
Outdoor temperature operating limits
kW
kW
kW
Indoor Units
Air flow (LS/NS/HS)
Acoustic pressure to 1 m (LS/HS)
Compressor type
Net weight
Built in casing (WxDxH)
Frame dimensions (WxDxH)
• Frame part number
• Part number 1~230 V
Outdoor Units
Air flow
Acoustic pressure to 1 m
Compressor type
Weight
Dimensions (WxDxH)
• Part number 1~230 V
ECF 9 DCI
ECF 12 DCI
2.5 (1.5-3.8)
0.59
4.2/A
°C
°C
kg
mm
m
m
Inches
Inches
20
10
3/8”
1/4”
ECF 18 DCI
27
WORLD
ARMOIRES
5 Heat Pump models DCI : from 3 400 to 9 000 W
Cassettes
ECF N &
ECFXL N
Product benefits
Designed for suspended ceiling integration.
● 900x900
mm format (ECFXL N).
● 600x600
mm format (ECF N).
● Built-in
depth : 287 mm (ECF N).
● Built-in
depth : 230 mm for ECFXL N (24 and 30 models).
● Electronic
regulation and programming.
●4
powered air distribution flaps (ECFXL N).
● New
air intake (ECF N).
● Possibility
of air conditioning an adjacent room (ECF N).
● Quick
access to all components after simply removing the facade.
● Phase
controller.
● Integrated
condensate drainage lift pump.
● Wall
mounted RCW2 remote control (accessory).
● Solid
ceiling frame (ECF N accessory).
● Compatible
with Airconet system regulation.
●
Indoor Units ECF N 9/11/15/18
OU 9/11/15
Indoor Units ECFXLN 24/30/36/45
OU 36/45
Cassettes range
: ECF/ECF XL DC INV
: ECF N/ECF XLN
LOW BUILT-IN HEIGHT
247 mm
ECF N
ECFXL N
RC3 Remote control
RCW2 Remote control (accessory)
• Part number 7ACEL1212
Accessories
ECF N 9
ECF N 11
ECF N 15
ECF N 18
ECFXL N 24 ECFXL N 30 ECFXL N 36 ECFXL N 45
Ceiling adapter frame • Part number 7ACVF0091 7ACVF0091 7ACVF0091 7ACVF0091 Mounting bracket
• Part number 7ACTL0016 7ACTL0016 7ACTL0016 7ACTL0018 7ACTL0018 7ACTL0018 7ACTL0013 7ACTL0013
28
8 Heat Pump models R410A : from 3 020 to 14 000 W
ECF N - ECFXL N SERIES
ECF N 9
ECF N 11
ECF N 15
ECF N 18 ECFXL N 24 ECFXL N 30 ECFXL N 36 ECFXL N 45
2.82
0.86
3.3/A
3.68
1.14
3.2/A
4.35
1.35
3.2/A
5.50
1.82
3.0/B
6.80
8.30
2.25
2.90
3.0/B
2.9/C
v21 °/46 ° Dry Bulbk
9.70
3.48
2.8/C
12.35
4.4
2.8/C
3.02
1.53
0.83
3.6/A
3.81
1.92
1.11
3.4/B
4.46
2.25
1.23
3.6/A
5.75
2.90
1.67
3.4/B
7.08
3.93
2.33
3.0/D
v-9 °/24 ° Dry Bulbk
10.30
3.60
2.8/D
14.00
5.50
2.54/F
m3/h
dB(A)
l/h
kg
mm
mm
430/470/580
35/36/41
0.8
23
571x571x287
625x625x40
Included
ESP042119
375/500/580
34/36/41
1.3
24
571x571x287
625x625x40
Included
ESP042120
430/550/630
36/41/44
1.6
26
571x571x287
625x625x40
Included
ESP042121
590/660/760
44/46/49
2.4
26
571x571x287
625x625x40
Included
ESP042122
690/800/910
38/41/44
2.5
36
840x840x230
950x950x46
EACVF0002
ESP042123
985/1120/1200 1025/1125/1220 1200/1300/1525
47/50/52
42/44/46
46/49/55
3.2
4.2
36
48
48
840x840x230 840x840x300 840x840x300
950x950x46 950x950x46
950x950x46
EACVF0002
EACVF0002
EACVF0002
ESP042124
ESP042134
ESP042135
m3/h
dB(A)
1780
49
Rotary
35
795x290x610
ESP061641
-
1850
53
Rotary
36
795x290x610
ESP061642
-
2160
54
Rotary
42
795x290x610
ESP061643
-
2480
58
Rotary
56
864x302x690
ESP061637
ESP061572
3100
58
Rotary
78
900x340x680
ESP061579
ESP061581
3150
59
Rotary
78
900x340x860
ESP061587
ESP061588
4150
61
Scroll
96
900x340x860
ESP061612
ESP061613
4350
Scroll
96
900x340x860
ESP061614
Linking specifications between indoor and outdoor units
Power supply 1~230 V
Power supply side
Indoor
Power cable section (without heating) mm2 3x1.5
Fuse rating am
A
16
Electrical connections
mm
5x1
Indoor
3x1.5
16
5x1.5
Indoor
3x1.5
16
5x1.5
Ind. or Out.
3x2.5
20
5x2.5*
Ind. or Out.
3x2.5
20
5x2.5*
Outdoor
3x4
25
6x1.5
-
-
Power supply 3N~400 V
Power supply side
Fuse rating am
Electrical connections
A
mm
-
-
-
Outdoor
3x8
6x1.5
Outdoor
3x10
6x2.5
Outdoor
3x16
6x1.5
Outdoor
3x20
6x1.5
Outdoor
3x20
6x1.5
Linking pipes
Max. lenght
Max. height
Suction pipe diameter
Liquid pipe diameter
m
m
Inches
Inches
15
7
3/8”
1/4”
15
7
3/8”
1/4”
15
7
1/2”
1/4”
25
15
1/2”
1/4”
30
15
5/8”
3/8”
30
15
5/8”
3/8”
50
25
3/4”
3/8”
50
25
3/4”
3/8”
Cooling Capacity
Power Input
EER/Energy Label
Out. temperature operating limits
kW
kW
Heating Capacity
Heating Capacity at -10 °C Out.
Power Input
COP/Energy Label
Out. temperature operating limits
kW
kW
kW
Indoor units
Air flow (LS/NS/HS)
Acoustic pressure to 1 m (LS/NS/HS)
Dehumidification
Weight
Built in casing (WxDxH)
Frame dimensions (WxDxH)
• Frame part number ECFXL
• Part number 1~230 V
Outdoor units
Air flow
Acoustic pressure to 1 m (LS/HS)
Compressor type
Weight
Dimensions (WxDxH)
• Part number 1~230 V
• Part number 3N~400 V
°C
°C
kg
mm
8.94
4.97
2.88
3.1/D
* In the case of connections to an indoor unit.
29
WORLD
ARMOIRES
EUROPE
AMBIANCE
electra 2008 air conditioning & heating catalogue
Floor/Ceiling
PXD DC
INVERTER
Product benefits
Horizontal
or vertical
unit
mounting
Perfect comfort, unequalled unobtrusiveness, great accuracy
in maintaining the desired temperature and controlling air quality.
● R410A «green» fluid.
● Optimal efficiency : Class A energy label (depending on models).
● Heating mode operation down to outdoor temperatures of -15 °C.
● Optimal temperature regulation.
● Electronic regulation and programming.
● Dual automatic treat air sweeping.
● Fluid
pre-charged at the factory for up to 20 m pipe lengths
(depending on models).
● Low wall or ceiling mounting.
● Possibility of air conditioning two separate rooms with a single unit.
● Compatible with AIRCONET regulation (PXD 24/30 DCI).
●
Possibility of air
conditioning
2 separate rooms
with a single unit
Floor/Ceiling range
: PXD DC INV
: PXD N NSA
OU PXD 9/12/18 DCI
PXD 9/12 DCI
RC4 Remote control
RCW2 Remote control (accessory)
OU PXD 24/28 DCI
• Part number 7ACEL1212
Accessories
Condensate lift pump
Air distribution unit
Rear panel tube cover
Mounting bracket
30
• Part number
• Part number
• Part number
• Part number
PXD 9 DCI
7ACFH0221
7ACVF0122
7ACTL0073
7ACTL0016
PXD 12 DCI
7ACFH0221
7ACVF0122
7ACTL0073
7ACTL0016
PXD 18 DCI
7ACFH0221
7ACVF0123
7ACTL0074
7ACTL0016
PXD 24 DCI
7ACFH0221
7ACVF0123
7ACTL0074
-
PXD 30 DCI
7ACFH0221
7ACVF0123
7ACTL0074
-
EUROPE
AMBIANCE
electra 2008 air conditioning & heating catalogue
5 Heat Pump models DCI : from 3 200 to 8 800 W
Cooling Capacity
Power Input
EER/Energy Label
Outdoor temperature operating limits
Heating Capacity
Heating Capacity at -15 °C
Power Input
COP/Energy Label
Outdoor temperature operating limits
Indoor Units
Air flow (LS/NS/HS)
Acoustic pressure to 1 m (LS/NS/HS)
Dehumidification
Weight
Dimensions (WxDxH)
• Part number 1~230 V
Outdoor Units
Air flow
Acoustic pressure to 1 m
PXD 9 DCI
PXD 12 DCI
PXD 18 DCI
2.5 (1.4-3.6)
0.62
4.0/A
3.5 (1.5-4.4)
0.98
3.6/A
5 (1.5-6.0)
6.8 (1.5-7.5)
1.65
2.24
3.0/B
3.0/B
v-10 °/46 ° Dry Bulbk
7.5 (2.0-9.5)
2.49
3.0/B
3.2 (1.5-4.5)
1.9
0.93
3.4/B
4.2 (1.5-5.0)
2.50
1.31
3.2/C
5.8 (1.5-7.2)
7.6 (1.5-8.8)
2.30
1.69
2.1
3.4/B
3.6/A
v-15 °/24 ° Dry Bulbk
8.8 (1.5-10.5)
2.46
3.41/B
m3/h
dB(A)
l/h
kg
mm
300/350/400
35/37/39
1
21
820x190x630
ESP012133
300/400/450
38/41/45
1.5
22
820x190x630
ESP012134
600/750/870
45/48/51
2
30
1200x190x630
ESP012135
760/930/1020
49/53/56
2.5
32
1200x190x630
ESP012164
760/930/1020
49/53/56
2.9
32
1200x190x630
ESP012165
m3/h
dB(A)
1780
50
1780
52
2160
53
3600
56
Twin Rotary DC
Inverter
66
950x412x835
ESP061600
kW
kW
°C
kW
kW
kW
°C
PXD 24 DCI
PXD 28 DCI
Rotary DC Inverter Rotary DC Inverter
Scroll DC Inverter
38
795x290x610
ESP061483
38
795x290x610
ESP061484
39
795x290x610
ESP061604
3600
56
Twin Rotary DC
Inverter
64,5
950x412x835
ESP061676
Linking specifications between indoor and outdoor units
Power supply
Power supply side
Indoor
Power cable section
mm2
3x1.5
Fuse rating am
A
16
Electrical connections
mm2
4x1.5
Indoor
3x1.5
16
4x1.5
Indoor
3x2.5
20
4x2.5
Indoor
3x2.5
20
4x2.5
Indoor
3x2.5
20
4x2.5
Linking pipes
Max. lenght
Max. height
Suction pipe diameter
Liquid pipe diameter
20
10
3/8"
1/4”
30
10
1/2"
1/4”
30
15
5/8"
3/8”
30
15
5/8"
3/8”
Compressor type
Weight
Dimensions (WxDxH)
• Part number 1~230 V
kg
mm
m
m
Inches
Inches
20
10
3/8"
1/4”
31
WORLD
ARMOIRES
PXD DC INVERTER SERIES
Floor/Ceiling
PXD N & NSA
Product benefits PXD N
Product benefits NSA
●
●
R410A «green» fluid.
● Low
wall or ceiling mounting indoor units.
● Automatic
vertical and horizontal treated air sweeping.
● Electronic
regulation and programming.
● Compact
and lightweight for easy installation and maintenance.
● Possibility
of air conditioning two separate rooms with a single
indoor unit.
● High
efficiency filtration.
● Compatible
with Airconet system regulation.
Multiposition architecture for low wall and ceiling mounting.
Indoor units direct blowing.
● Linking
pipes until 50 m.
● Compatible
with Airconet system regulation.
●
Floor/Ceiling range
: PXD DC INV
: PXD N NSA
NSA 45
PXD N 18/24/30
OU PXD N 9/12/14
RC4 Remote control
RCW2 Remote control (accessory)
OU 36/45
• Part number 7ACEL1212
Accessories
PXD N 9
PXD N 12
1250
1250
Capacity (W)
Single phase electric heating
• Part number 7ACEL1153 7ACEL1153
Capacity (W)
1000
Single phase electric heating
• Part number 7ACEL1172
Capacity (W)
Three phases electric heating
• Part number Condensate lift pump
• Part number 7ACFH0221 7ACFH0221
Air distribution unit
• Part number 7ACVF0122 7ACVF0122
Rear panel tube cover (ceiling mounting) • Part number 7ACTL0073 7ACTL0073
Mounting bracket
• Part number 7ACTL0016 7ACTL0016
All seasons kit
• Part number 7ACFH0480 7ACFH0480
Important : installation of an all season kit only allows for operation in cooling mode.
32
PXD N 15
2000
7ACEL1154
1000
7ACEL1172
7ACFH0221
7ACVF0122
7ACTL0073
7ACTL0016
7ACFH0480
PXD N 18
2000
7ACEL1154
7ACFH0221
7ACVF0123
7ACTL0074
7ACTL0016
7ACFH0480
PXD N 24
3000
7ACEL1155
1500
7ACEL1173
3000
7ACEL1156
7ACFH0221
7ACVF0123
7ACTL0074
7ACTL0018
7ACFH0480
PXD N 30
3000
7ACEL1155
1500
7ACEL1173
3000
7ACEL1156
7ACFH0221
7ACVF0123
7ACTL0074
7ACFH0480
EUROPE
AMBIANCE
electra 2008 air conditioning & heating catalogue
PXD N SERIES
PXD N 9 RC
PXD N 12 RC PXD N 15 RC PXD N 18 RC PXD N 24 RC PXD N 30 RC NSA 45RC
2.66
0.82
3.2/A
3.52
1.15
3.1/B
4.1
1.35
3.0/B
v21 °/46 ° Dry Bulbk
5.5
1.82
3.0/B
6.83
2.27
3.0/B
8.52
2.99
2.9/C
13
4.56
2.85/C
2.79
1.41
0.86
3.2/C
3.7
1.87
1.15
3.2/C
4.5
2.27
1.38
3.3/C
v-9 °/24 ° Dry Bulbk
5.75
2.9
1.77
3.3/C
7.03
3.91
2.13
3.3/C
8.65
4.81
2.79
3.1/D
13.9
4.86
2.86/D
m3/h
dB(A)
l/h
kg
mm
290/330/370
35/37/39
1.1
21
820x190x630
ESP012137
350/390/420
38/41/45
1.5
22
820x190x630
ESP012138
350/390/510
38/43/48
1.9
22
820x190x630
ESP012139
700/820/930
45/48/51
1.9
30
1200x190x630
ESP012140
780/900/1000
48/51/53
2.7
33
1200x190x630
ESP012141
700/895/1020
49/53/56
3.4
32
1200x190x630
ESP012136
1300/1480/1600
53/56/58
56
1585x255x590
ESP022394
m3/h
dB(A)
1780
49
Rotary
35
795x290x610
ESP061641
-
1850
53
Rotary
36
795x290x610
ESP061642
-
2160
54
Rotary
42
795x290x610
ESP061643
-
2480
58
Rotary
56
846x302x690
ESP061637
ESP061572
3100
58
Rotary
74
900x340x680
ESP061680
ESP061581
3150
59
Rotary
78
900x340x860
ESP061587
ESP061588
4350
64
Scroll
96
900x340x970
ESP061614
Linking specifications between indoor and outdoor units
Power supply 1~230 V
Power supply side
Indoor
Power cable section (without heating) mm2
3x1.5
Fuse rating am
A
10
Electrical connections
mm
5x1.5
Indoor
3x1.5
16
5x1.5
Indoor
3x1.5
16
5x1.5
Indoor
3x2.5
16
5x1.5
Ind. or Out.
3x2.5
20
5x2.5*
Outdoor
3x4
25
6x1.5
-
Power supply 3N~400 V
Power supply side
Power cable section (without heating) mm2
Fuse rating am
A
Electrical connections
mm
-
-
-
Outdoor
5x1.5
3x10
6x1.5
Outdoor
5x1.5
3x10
6x1.5
Outdoor
5x2.5
3x16
6x1.5
Outdoor
5x2.5
3x20
6x2.5
15
7
3/8”
1/4”
15
7
3/8”
1/4”
15
7
1/2”
1/4”
25
15
1/2”
1/4”
30
15
5/8”
3/8”
30
15
5/8”
3/8”
50
25
3/4”
3/8”
Cooling Capacity
Power Input
EER/Energy Label
Out. temperature operating limits
kW
kW
Heating Capacity
Heating Capacity at -10 °C Out.
Power Input
COP/Energy Label
Out. temperature operating limits
kW
kW
kW
Indoor units
Air flow (LS/NS/HS)
Acoustic pressure to 1 m (LS/HS)
Dehumidification
Weight
Dimensions (WxDxH)
• Part number
Outdoor units
Air flow
Acoustic pressure to 1 m (LS/HS)
Compressor type
Weight
Dimensions (WxDxH)
• Part number 1~230 V
• Part number 3N~400 V
°C
°C
kg
mm
Linking pipes
Max. lenght
m
Max. height
m
Suction pipe diameter
Inches
Liquid pipe diameter
Inches
* In the case of connections to an indoor unit.
33
WORLD
ARMOIRES
7 Heat Pump models R410A: from 2 790 to 13 900 W
LSN DC
Ducted
INVERTER
Product benefits
Obvious solution to all installation constraints.
● Extreme
low silhouette only: 200 mm.
● Integrated condensate drainage lift pump.
● Horizontal/Vertical installation builds in.
● Air distribution / air intake plenums available in accessory.
● Optimal efficiency Class A energy label (depending on models).
● Electronic regulation and programming.
● Heating mode operation down to outdoor temperatures of -15° C.
● Compatible with DUO, TRIO and QUATTRO DCI Multisplits.
● Up to 50 m pipe length between indoor and outdoor unit.
● Up to 30 m vertical high between indoor and outdoor unit.
*Wall mounted RCW2 remote control (Optional)
Ducted range
: LSN DCI
: LS R407C
DNG DCI
DLS R410A
OU 9/12/18 DCI
LSN 24 DCI
RC3 Remote control
OU 24 DCI
Accessories
Mounting bracket
Remote control RCW2
34
• Part number
• Part number
LSN 9 DC INV
7ACTL0016
7ACEL1212
LSN 12 DC INV
7ACTL0016
7ACEL1212
LSN 18 DC INV
7ACTL0016
7ACEL1212
LSN 24 DC INV
7ACEL1212
EUROPE
AMBIANCE
electra 2008 air conditioning & heating catalogue
4 DC Inverter models: from 3 400 W to 7 600 W
Cooling Capacity
Power Input
EER/Energy Label
Outdoor temperature operating limits
kW
kW
Heating Capacity
Power Input
COP/Energy Label
Outdoor temperature operating limits
kW
kW
LSN 9 DC INV
LSN 12 DC INV
2,5 (1,4-3,6)
0,61
4,1/A
3,5 (1,4-4,3)
5 (1,5-6,0)
0,94
1,55
3,7/A
3,3/A
v-10°/46° Dry bulb k
7,0 (1,5-7,5)
2,05
3,4/A
3,4 (1,5-5,0)
0,86
3,95/A
4,3 (1,6-5,5)
6,1 (1,5-7,6)
1,16
1,74
3,85/A
3,5/B
v-15°/24° Dry bulb k
7,6 (1,5-8,8)
1,96
3,87/A
°C
°C
LSN 18 DC INV
LSN 24 DC INV
Indoor Units
Sound pressure level to 1 m (LS/MS/HS)
Sound power level (LS/MS/HS)
Airflow (LS/MS/HS)
Dehumidification
Dimensions (WxDxH)
Weight
• Part number
dB(A)
dB(A)
m3/h
l/h
mm
kg
23/26/29
44/47/50
420/490/560
0,5
750x200x630
20
ESP022396
24/27/31
45/49/53
510/590/650
1
750x200x630
20
ESP022397
29/32/35
48/51/54
540/650/750
1,5
750x200x630
20
ESP022398
32/35/39
56/59/63
900/1050/1200
2
1050x200x630
25
ESP022400
Outdoor Units
Sound pressure level to 1 m
Sound power level
Airflow
Compressor type
Dimensions (WxDxH)
Weight
• Part number
dB(A)
dB(A)
m3/h
kg
mm
kg
52
62
1780
Rotary DC Inverter
795x290x610
38
ESP061483
52
62
1780
Rotary DC Inverter
795x290x610
38
ESP061484
53
63
2160
Scroll DC Inverter
795x290x610
39
ESP061604
56
66
3600
Twin Rotary DC Inverter
950x412x835
64.5
ESP061676
Linking specifications between indoor and outdoor units
Power supply 1-230V
Power supply side
Power cable section
mm2
Fuse rating am
A
Electrical connections
mm2
Indoor
3x1,5
16
4x1,5
Indoor
3x1,5
16
4x1,5
Indoor
3x2,5
20
4x2,5
Outdoor
3x2,5
20
4x2,5
Linking pipes
Suction pipe diameter
Liquid pipe diameter
Max lenght
Max height
3/8”
1/4”
20
15
3/8”
1/4”
20
15
1/2”
1/4”
30
15
5/8”
3/8”
50
30
inches
inches
m
m
35
WORLD
ARMOIRES
LSN DCI INVERTER SERIES
DNG DC
Ducted
INVERTER
Product benefits
Designed for integration in suspended ceilings.
Low noise levels.
● Low built-in height: DNG = 260 mm.
● R410A ”green” fluid.
● High efficiency filtration.
● Optimal efficiency: Class A energy label.
● Heating mode operation down to outdoor temperatures of -15° C.
● Optimal temperature regulation.
● Electronic regulation and programming.
● Fluid pre-charged at the factory for up to 20 m pipe lengths. (depending on models).
● Compatible with AIRCONET regulation.
●
●
*Wall mounted RCW2 remote control (Optional)
: LSN DCI
DNG DCI
: LS R407C
DLS R410A
OU 30/36/43 DCI
DNG 30/36/43 DCI
RC3 Remote control
Accessories
Air supply plenum
Remote control RCW2
36
• Part number
• Part number
DNG 30 DC INV
7ACVF0317
7ACEL1212
DNG 36 DC INV
7ACVF0317
7ACEL1212
DNG 43 DC INV
7ACVF0317
7ACEL1212
EUROPE
AMBIANCE
electra 2008 air conditioning & heating catalogue
DNG DC INVERTER SERIES
DNG 30 DC INV
DNG 36 DC INV
DNG 43 DC INV
7,5
2,4
3,0/B
10
3,12
3,21/A
v-10°/46° Dry bulb k
12,5
4,1
3,0/B
8,8
2,44
3,6/A
11,2
3,6
3,1/D
v-15/24° Dry Bulb k
14
4,3
3,25/C
dB(A)
dB(A)
m3/h
l/h
mm
kg
40/44/48
58/61/64
935/1150/1320
2,5
790x256x749
31
ESP022366
47/49/52
62/67/71
1420/1860/2180
3,3
854x300x816
33
ESP032001
47/49/52
62/67/71
1580/1920/2180
4,6
854x300x816
33
ESP032002
dB(A)
dB(A)
m3/h
56
66
3600
Twin Rotary DCI
950x412x835
66
ESP061600
56
69
5200
Scroll DCI
1255x340x900
110
ESP061681
61
73
5700
Scroll DCI
1255x340x900
110
ESP061682
Linking specifications between indoor and outdoor units
Power supply 1-230V
Power supply side
Power cable section
mm2
Fuse rating am
A
Electrical connections
mm2
Outdoor
3x2,5
20
4x2.5
Outdoor
3x4,0
25
3x1.5
Outdoor
3x6,0
32
3x1.5
Linking pipes
Suction pipe diameter
Liquid pipe diameter
Max lenght
Max height
5/8''
3/8''
50
25
5/8''
3/8''
70
30
3/4''
3/8''
70
30
Cooling Capacity
Power Input
EER/Energy Label
Outdoor temperature operating limits
Heating Capacity
Power Input
COP/Energy Label
Outdoor temperature operating limits
Indoor Units
Sound pressure level to 1 m (LS/MS/HS)
Sound power level (LS/MS/HS)
Airflow (LS/MS/HS)
Dehumidification
Dimensions (WxDxH)
Weight
• Part number
Outdoor Units
Sound pressure level to 1 m
Sound power level
Airflow
Compressor type
Dimensions (WxDxH)
Weight
• Part number
kW
kW
°C
kW
kW
°C
mm
kg
inches
inches
m
m
WORLD
ARMOIRES
3 DC Inverter models: from 8 800 W to 14 000 W
37
LS & DNG
Ducted
Product benefits
Low silhouette ducted units.
Suspended ceiling installation.
● Low
built-in height : (LS= 245 mm; DNG= 260mm).
● High
available air pressure for connection to a duct network.
● New
centrifugal fan type.
● Low
noise levels.
● Electronic
regulation and programming.
● Air
filter supplied, easy access.
● Electric
heating (accessory).
● Airconet
compatible system.
●
●
Ducted range
: LS/DNG DCI
: LS/DNG
Indoor unit LS 35 RC
Outdoor unit
RC4 Remote control
Indoor unit DNG 18/24/30
RCW2 Remote control (accessory)
• Part number 7ACEL1212
Accessories
Electric heating
Air supply plenum
Mounting bracket
All seasons kit
N°1 Cassette air intake plenum kit
N°2 Cassette air intake plenum kit
38
Capacity (W)
• Part number
• Part number
• Part number
• Part number
• Part number
• Part number
LS 35
1600
7ACEL1305
7ACTL0016
7ACVF0075
7ACVF0073
DNG 18 RC
2000
7ACEL1358
7ACVF0317
7ACTL0018
7ACFH0480
-
DNG 24 RC
2000
7ACEL1358
7ACVF0317
7ACFH0480
-
DNG 30 RC
3000
7ACEL1359
7ACVF0317
7ACFH0480
-
DNG 37 RC
4000
7ACEL1360
7ACVF0318
-
DNG 44 RC
4000
7ACEL1360
7ACVF0318
-
EUROPE
AMBIANCE
electra 2008 air conditioning & heating catalogue
LS & DNG SERIES
LS 35 RC
DNG 18 RC
DNG 24 RC
3.4
1.23
2.8/C
5.6
1.8
3.1/B
6.9
2.4
2.9/C
3.4
2.4
1.2
2.8/D
5.3
2.94
1.7
3.1/D
7
3.89
2.3
3.0/D
m3/h
dB(A)
dB(A)
l/h
kg
mm
360/450/580
30
33/35/42
1.3
30
860x680x245
ESP022219
730/875/1150
25/60
40/42/45
2
29
790x749x256
ESP022285
840/1100/1210
25/60
43/45/48
2.3
29
790x749x256
ESP022286
dB(A)
53
Rotary
39
795x290x610
ESP061502
-
58
Rotary
56
846x302x690
ESP061637
ESP061572
Linking specifications between indoor and outdoor units
Power supply 1~230 V - 50 Hz
Power supply side
Indoor
Power cable section (without heating)
mm2
3x1.5
Fuse rating am
A
10
Electrical connections
mm
6x1.5
Power supply 3N~400 V - 50 Hz
Power supply side
Power cable section (without heating)
Fuse rating am
Electrical connections
mm2
A
mm
Linking pipes
Max. lenght
Max. height
Suction pipe diameter
Liquid pipe diameter
m
m
Inches
Inches
Cooling Capacity
Power Input
EER/Energy Label
Out. temperature operating limits
kW
kW
Heating Capacity
Heating Capacity at -10 °C Outdoor
Power Input
COP/Energy Label
Outdoor temperature operating limits
kW
kW
kW
Indoor units
Air flow (LS/NS/HS)
Static pressure (LS/HS)
Acoustic pressure to 1 m (LS/HS)
Dehumidification
Weight
Dimensions (WxDxH)
• Part number 1~230 V
Outdoor units
Acoustic pressure to 1 m
Compressor type
Net weight
Dimensions (WxDxH)
• Part number 1~230 V
• Part number 3N~400 V
DNG 37 RC
DNG 44 RC
8.5
3
2.8/C
v21 °/46 ° Dry Bulbk
10.6
3.8
2.8/C
12.4
4.3
2.8/C
9
5
2.8
3.2/C
v-9 °/24 ° Dry Bulbk
11.2
6.22
3.7
3.1/D
13.1
7.67
4.3
3.0/D
935/1150/1420
37/80
44/46/49
3
31
790x749x256
ESP022287
1210/1520/1840
37/100
45/48/51
3.7
33
852x816x297
ESP022288
1250/1490/2040
50/100
47/49/52
4.7
33
852x816x297
ESP022289
58
Rotary
78
900x340x680
ESP061680
ESP061581
58
Rotary
78
900x340x860
ESP061587
ESP061588
63
Rotary
87
900x340x970
ESP061613
64
Scroll
87
900x340x970
ESP061614
Indoor
3x2.5
20
6x2.5
Ind. or Out.
3x2.5
20
6x1.5*
Outdoor
3x4
25
6x1.5
Outdoor
3x4
25
6x1.5
-
-
Outdoor
5x1.5
3x10
6x1.5
Outdoor
5x1.5
3x10
6x1.5
Outdoor
5x2.5
3x16
6x1.5
Outdoor
5x2.5
3x16
6x1.5
Outdoor
5x2.5
3x16
6x1.5
15
7
1/2”
1/4”
25
15
1/2”
1/4”
50
25
5/8”
3/8”
50
25
5/8”
3/8”
50
25
3/4”
3/8”
50
25
3/4”
3/8”
°C
°C
kg
mm
DNG 30 RC
* In the case of connections to an indoor unit.
39
WORLD
ARMOIRES
6 Heat Pump models R410A : from 3 400 to 13 100 W
Mobiles
Smily N
Product benefits
Class A energy label (depending on models).
Direct control (CD) and infrared remote control (IR).
● Resolutely
modern design.
● Compact
and lightweight for easy repositioning.
●
●
SMILY N 14IR
1 Heat Pump model R410A: 4 590 W
SMILY N SERIES
SMILY N 14IR
Cooling Capacity
Power Input
EER/Energy Label
Dehumidification
Outdoor temperature operating limits
kW
kW
Heating Capacity
Power Input
COP/Energy Label
kW
kW
Indoor units
Air flow (LS/NS/HS)
Acoustic pressure to 1 m (LS/NS/HS)
Compressor type
Weight
Dimensions (WxDxH)
Outdoor units
Compressor type
Weight
Dimensions (WxDxH)
• Part number 1~230 V
Linking specifications between indoor and outdoor units
Linking pipes
Max. lenght
Max. height
40
l/h
°C
m3/h
dB(A)
kg
mm
4.17
1.54
2.7/A
1.80
4.59
1.39
3.3/A
Split system
356/401/433
48/50/51
38
470x360x800
kg
mm
Rotary
17
440x320x540
EMB021044
m
m
3
1.6
electra 2008 air conditioning & heating catalogue
Monobloc air console
JKF
Product benefits
New monobloc console concept without an outdoor unit.
Ideal solution for premises where it is impossible to install an outdoor unit.
● Easy installation and maintenance.
● Ready to operate system.
● Floor mounted or low wall mounted.
● Compact design.
● Reinforced acoustic insulation.
● R410A high efficiency fluid.
● Factory-fitted 1 500 W electric heating.
● LED direct control panel.
● Electrostatic filter.
● Condensate drainage pipe supplied.
● Rear outlet grille kit supplied.
● Airconet compatible system.
●
EUROPE
AMBIANCE
●
Control panel
JKF 9
JKF SERIES
Cooling Capacity
Power Input
EER/Energy Label
Outdoor temperature operating limits
Indoor unit
Air flow (LS/NS/HS)
Acoustic pressure to 1 m (LS/NS/HS)
Dehumidification
Weight
Dimensions (WxDxH)
• Part number 1~230 V
WORLD
ARMOIRES
1 Cooling Only model : 2 520 W
JKF 9
kW
kW
°C
m3/h
dB(A)
l/h
kg
mm
2.52
0.97
2.6/C
21 °/43 ° Dry Bulb
315/360/400
42/44/47
1
42
1 110X240X382
EWT012048
41
AWD
Windows
Product benefits
Easy installation.
Sober, unobtrusive styling.
● For
flush fitting into a wall or a window.
● Very
compact solution.
● Re-usable
filters.
● Sliding
drawer chassis.
●
●
AWD 15/25
AWD 50/61
5 Cooling Only models R407C : from 2 140 to 6 400 W
1 Heat Pump models R22 : 3 200 W
AWD SERIES
Cooling Capacity
Power Input
EER/Energy Label
Out. temperature operating limits
Indoor units
Air flow (NS)
Acoustic pressure to 1 m (LS/HS)
Compressor type
Weight
Dimensions (WxDxH)
• Part number 1~230 V
Linking specifications between units
Power supply 1~230 V
Power cable section
Fuse rating am
kW
kW
AWD 15
AWD 25
AWD 32
2.14
0.82
2.6/C
2.54
1.06
2.4/D
3.28
5.0
1.46
2.25
2.2/E
2.2/E
fl21 °/46 ° Dry Bulb‡
6.4
2.65
2.4/D
310
41/44
Rotary
37
450x590x350
EWT012043
340
42/46
Rotary
37
450x590x350
EWT012044
500
54/59
Rotary
47
560x610x375
EWT012040
800
54/59
Rotary
63
670x710x455
EWT012041
920
57/61
Rotary
70
670x710x455
EWT012042
3x1.5
6
3x1.5
6
3x1.5
8
3x1.5
10
3x1.5
16
°C
m3/h
dB(A)
kg
mm
mm2
A
AWD SERIES
AWD 32 RC
Cooling Capacity
Power Input
EER/Energy Label
kW
kW
3.2
1.33
2.5/D
Heating Capacity
Power Input
COP/Energy Label
kW
kW
3.2
1.1
2.9/D
m3/h
dB(A)
500
53/55
Rotary
47
560x610x375
7001736
Indoor units
Air volume (MS)
Acoustic pressure to 1 m (LS/MS/HS)
Compressor type
Weight
Dimensions (WxDxH)
• Part number 1~230 V
Linking specifications between units
Power supply 1~230 V
Power cable section
Fuse rating am
42
kg
mm
mm2
A
3x1.5
8
AWD 50
AWD 61
electra 2008 air conditioning & heating catalogue
Column
CCE
Multifunction control panel
Automatic Cooling/Heating regulation.
3 fan (ventilation) speeds.
● Automatic
ventilation.
● Night
time low running (SLEEP) function.
● Dehumidification
mode.
● Programming
(TIMER) function.
● LCD display.
●
Product benefits
LCD screen.
High efficiency filtration.
● Clogged
filter indicator.
● Scroll
compressor.
● Ioniser.
● Automatic
treated air sweeping.
● New
air intake option.
● Electronic
regulation and programming
(daily and weekly).
● Linking
pipe lenghts up to 50 m.
● Airconet
connection (options).
●
●
CCE 45 RC
1 Heat Pump model R410A : 13 200 W
CCE SERIES
CCE 45 RC
Cooling Capacity
Power Input
EER/Energy Label
Outdoor temperature operating limits
kW
kW
Heating Capacity
Power Input
COP/Energy Label
Outdoor temperature operating limits
kW
kW
Outdoor units
Compressor type
Acoustic pressure to 1 m
Weight
Dimensions (WxDxH)
• Part number
°C
°C
m3/h
dB(A)
kg
mm
12.3
4.4
2.8/C
v21 °/46 ° Dry Bulbk
13,2
4.63
2.8/D
v-9 °/24 ° Dry Bulbk
2000
52/56
70
600x370x1900
ESP022415
OU 45 RC
dB(A)
kg
mm
Scroll
64
95
900x340x970
ESP061615
Electrical data
Power supply 3N~400 V
Power supply side
Supply cable
Fuse calibration
Electrical connections
mm2
A
mm2
Outdoor
5x2.5
3x10
6x2.5
Tubing
Max. lenght
Max. height
Suction pipe diameter
Liquid pipe diameter
m
m
Inches
Inches
50
25
3/4”
3/8”
WORLD
ARMOIRES
Indoor units
Air flow (HS)
Acoustic pressure to 1 m (min/max)
Weight
Dimensions (WxDxH)
• Part number
EUROPE
AMBIANCE
●
43
Multisplits
DUO-TRIO
QUATTRO DC
INVERTER
Product benefits
Outdoor units compatible with DC Inverter indoor units.
R410A «green» fluid.
● DC
Inverter Twin Rotary compressor (depending on models).
● Compact
outdoor units.
● Class
A energy label.
● Heating
mode operation down to outdoor temperatures of -15 °C.
● Set
temperature point reached rapidly.
● Silent
running.
● Up
to 70m pipe lengths.
●
●
DUO DCI
TRIO DCI
Compatibilities
CN DCI indoor units
ECF DCI indoor units
PXD DCI indoor units
LSN DCI indoor units
44
Cooling Capacity
Heating Capacity
Air flow
Sound pressure level to 1 m
Weight
Dimensions (WxDxH)
• Part number
kW
kW
m3/h
dB(A)
kg
mm
Cooling Capacity
Heating Capacity
Air flow
Sound pressure level to 1 m
Weight
Dimensions (WxDxH)
• Part number
kW
kW
m3/h
dB(A)
kg
mm
Cooling Capacity
Heating Capacity
Air flow
Sound pressure level to 1 m
Weight
Dimensions (WxDxH)
• Part number
kW
kW
m3/h
dB(A)
kg
mm
Cooling Capacity
Heating Capacity
Air flow
Sound pressure level to 1 m
Weight
Dimensions (WxDxH)
• Part number
kW
kW
m3/h
dB(A)
kg
mm
CN 9 DCI
2,5 (0,9-3,4)
3,2 (0,9-4,2)
460
29/35
16
575x575x219
ESP022401
ECF 9 DCI
CN 12 DCI
3,5 (0,9-4,0)
4,2 (0,9-4,8)
460
29/35
16
575x575x219
ESP022402
ECF 12 DCI
CN 18 DCI
5 (1,55-6,4)
5,8 (1-7)
780
36/42
16
575x575x270
ESP022403
ECF 18 DCI
2,5
3,4
450/530/600
32/37
23
571x571x287
ESP042116
3,5
4,3
450/560/620
32/37
24
571x571x287
ESP042117
5
6,3
510/630/730
36/48
28
571x571x287
ESP042118
PXD 9 DCI
2,5
3,2
300/350/400
35/37/39
21
820x190x630
ESP012133
PXD 12 DCI
3,5
4,2
300/400/450
38/41/45
22
820x190x630
ESP012134
PXD 18 DCI
LSN 9 DCI
LSN 12 DCI
LSN 18 DCI
2,5
3,4
420/490/560
44/47/50
20
820x245x630
ESP022396
3,5
4,3
45/49/53
20
20
860x245x630
ESP022397
5
5,8
600/750/870
45/48/51
30
1200x192x630
ESP012135
5
6,1
540/650/750
48/51/54
20
860x245x630
ESP022398
EUROPE
AMBIANCE
electra 2008 air conditioning & heating catalogue
3 Heat Pump models DCI: from 6 200 W to 9 500 W
DUO 50 DCI
TRIO 72 DCI
5 (1,2-6,48)
1,47
3,4 / A
7,2 (1,3-9)
8 (1,4-9,2)
2,24
2,49
3,2 / A
3,2 / A
v-10°/ 46° Dry Bulb k
6,2 (0,95-7,75)
3,7
1,67
3,71 / A
9 (0,95-11)
5,4
2,37
3,8 / A
v-15/24° Dry Bulb k
9,5 (0,95-11)
5,7
2,38
4/A
53
63
2160
Scroll DC Inverter
795x290x610
43
ESP091126
54
64
3200
Twin Rotary DC Inverter
950x340x835
69
ESP061605
54
64
3200
Twin Rotary DC Inverter
950x340x835
70
ESP061606
Linking specifications between indoor and outdoor units
Power supply 1-230V
Power supply side
Power cable section
mm2
Fuse rating am
A
Electrical connections
mm2
Suction pipe diameter
inches
Liquid pipe diameter
inches
Outdoor
3x2,5
16
2x(4x1,5)
2x3/8”
2x1/4”
Outdoor
3x2,5
20
3x(4x1,5)
2x3/8” + 1x1/2”
3x1/4”
Outdoor
3x2,5
20
4x(4x1,5)
3x3/8” + 1x1/2”
4x1/4”
Linking pipes
Max lenght
Max height per circuit
Max height between indoor and oudoor units
Max height between indoor units
30
25
10
5
50
25
15
15
70
25
15
15
Cooling Capacity
Power Input
EER/Energy Label
Outdoor temperature operating limits
kW
kW
Heating Capacity
Capacity at -15°C
Input power
COP/Energy Label
Outdoor temperature operating limits
kW
kW
kW
Sound pressure level to 1 m
Sound power level
Air flow
Compressor type
Dimensions (WxDxH)
Weight
• Part number
dB(A)
dB(A)
m3/h
Accessory
Mounting bracket
°C
°C
mm
kg
m
m
m
m
QUATTRO 80 DCI
WORLD
ARMOIRES
OUTDOOR UNITS
DUO 50 DC INV
7ACTL0016
45
Multisplits
DUO R410A
Product benefits
Compact outdoor units.
Units equipped with 2 compressors.
● Independent
operation of each indoor unit.
● Outdoor
units compatibles with WNG and ALPHA indoor units.
● R410A
«green» fluid.
● Rotary
compressor.
● Hydrophilic
condenser coating.
● Heating
mode operation down to outdoor temperatures of -10° C.
● Silent
running.
●
●
Multislits range
: DUO/TRIO DELTA
: DUO R410A
Outdoor unit DUO 18/18 24/24
Outdoor unit DUO 9/9 9/12 12/12
Compatibilities
COMPACT F
WALL MOUNTED
Cooling Capacity
Heating Capacity
Air flow (LS/NS/HS)
Acoustic pressure to 1 m
Weight
Dimensions (WxDxH)
• Part number
WALL MOUNTED
WNG 9/12/14N
Cooling Capacity
Heating Capacity
Air flow (LS/NS/HS)
Acoustic pressure to 1 m
Weight
Dimensions (WxDxH)
• Part number
kW
kW
m3/h
dB(A)
kg
mm
46
COMPACT F12
3.6
3.8
460/620
33/40
8
840x180x250
ESP022410
kW
kW
m3/h
dB(A)
kg
mm
COMPACT F18
5.0
5.0
450/670
35/44
15
900x200x295
ESP022411
WNG 24N RC
kW
kW
m3/h
dB(A)
kg
mm
WALL MOUNTED
Cooling Capacity
Heating Capacity
Air flow (LS/NS/HS)
Acoustic pressure to 1 m
Weight
Dimensions (WxDxH)
• Part number
COMPACT F9
2.76
3.0
350/450
35/40
7
680x180x250
ESP022409
6.7
7.0
740/820/910
42/44/47
15
1060x210x295
ESP022272
TOP 9
TOP 12
2.6
2.8
330/360/390
31/33/35
13.5
570x160x570
ESP022340
3.3
3.7
310/360/430
32/35/39
14
570x160x570
ESP022341
EUROPE
AMBIANCE
electra 2008 air conditioning & heating catalogue
DUO R410 SERIES
DUO 9/9 RC
DUO 9/12 RC
DUO 12/12 RC DUO 18/18 RC
DUO 24/24 RC
Cooling Capacity
Power Input
Outdoor temperature operating limits
kW
kW
°C
5.72 (2x2.86)
1.9
5.93 (2.86+3,07)
2.07
7 (3.5x2)
10.7 (5.35x2)
2.5
3.32
v21 °/46 ° Dry Bulbk
13 (6.5x2)
4.6
Heating Capacity
Power Input
Outdoor temperature operating limits
kW
kW
°C
5.37 (2.6x2)
1.79
6.13 (2.6+3.53)
1.97
7.03 (3.51x2)
10.8 (5.4x2)
2.51
3.32
v-10 °/24 ° Dry Bulbk
14 (7x2)
4.81
m3/h
dB(A)
1100/1520
59
Rotary
72
900x340x680
ESP061635
1100/1520
59
Rotary
74
900x340x680
ESP061636
1100/1520
59
Rotary
74
900x340x680
ESP091146
4500
60
Rotary
110
950x340x1270
ESP091147
4950
62
Rotary
110
950x340x1270
ESP091148
Linking specifications between indoor and outdoor units
Power supply 1~230 V
Power supply side
Outdoor
Power cable section (without heating)
mm2
3x2.5
Fuse rating am
A
16
Electrical connections
mm
6x1.5
Outdoor
3x2.5
16
6x1.5
Outdoor
3x2.5
16
6x1.5
Outdoor
3x2.5
16
6x1.5
Outdoor
5x2.5
16
6x1.5
Linking pipes
Max. lenght
Max. height
Suction pipe diameter
Liquid pipe diameter
15
7
2x3/8”
2x1/4”
15
7
2x3/8”
2x1/4”
25
15
2x1/2”
2x1/4”
25
15
2x5/8”
2x3/8”
Outdoor units
Air flow
Acoustic pressure to 1 m
Compressor type
Net weight
Dimensions (WxDxH)
• Part number 1~230 V
kg
mm
m
m
Inches
Inches
15
7
2x3/8”
2x1/4”
47
WORLD
ARMOIRES
5 Heat Pump models R410A: from 5 370 to 14 000 W
Multisplits
Product benefits
DUO/TRIO DELTA
DC INTERVER
Multisplits 3 in 1, configuration 9-9, 9-12, 12-12.
Outdoor units compatible with DELTA DC Inverter indoor units.
● R410A
«green» fluid.
● DC
Inverter Scroll compressor.
● Compact
outdoor units.
● Class
A energy label.
● Heating
mode operation down to outdoor temperatures of -15 °C.
● Set
temperature point reached rapidly.
● Silent
running.
●
●
Multisplits range
: DUO/TRIO DELTA
: DUO R410A
OU DUO DELTA DCI
Compatibilities
DELTA DCI
48
WALL MOUNTED
Cooling Capacity
Heating Capacity
Air flow (LS/NS/HS)
Acoustic pressure to 1 m
Weight
Dimensions (WxDxH)
• Part number
OU TRIO DELTA DCI
kW
kW
m3/h
dB(A)
kg
mm
DELTA 7 DCI
2.2
2.5
300/350/400
30/33/36
7
680x180x250
ESP022275
DELTA 9 DCI
2.5
2.8
270/350/420
32/35/39
7
680x200x250
ESP022276
DELTA 12 DCI
3.5
3.6
350/450/550
29/33/39
8
840x200x250
ESP022277
EUROPE
AMBIANCE
electra 2008 air conditioning & HEATING catalogue
2 Heat Pump model DCI : from 4 500 W to 6 600 W
DUO DELTA DCI
Cooling Capacity
Power Input
EER/Energy Label
Outdoor temperature operating limits
kW
kW
Heating Capacity
Power Input
COP/Energy Label
Outdoor temperature operating limits
kW
kW
Outdoor units
Air flow
Acoustic pressure to 1 m
Compressor type
Net Weight
Dimensions (WxDxH)
3.9 (1.2-5.5)
1.14
3.2/A
°C
°C
m3/h
dB(A)
TRIO DELTA DCI
5.2 (1.0-6.5)
1.55
3.35/A
-10 °/46 ° Dry Bulb
4.5 (1.2-6.2)
6.6 (1.0-7,3)
1.24
1.8
3.62/A
3,67/A
-15 °/24 ° Dry Bulb
2160
53
Rotary DC Inverter
38
795x290x610
2860
56
Scroll DC Inverter
48
846x302x690
Linking specifications between indoor and outdoor units
Power supply 1~230 V
Power supply side
Power cable section
mm2
Fuse rating am
A
Electrical connections indoor/outdoor
mm
Outdoor
3x2.5
16
2x(4x1.5)
Outdoor
3x2.5
20
3x(4x1.5)
Linking pipes
Max. lenght
Max. lenght between per circuit
Max. height between indoor and outdoor units
Max. height between indoor units
Liquid pipe diameter
Suction pipe diameter
• Part number 1~230 V
30
25
10
5
2x1/4”
2x3/8”
ESP091149
35
25
15
5
3x1/4”
3x1/2”
ESP091150
DUO DELTA DC INV
7ACTL0016
TRIO DELTA DC INV
7ACTL0018
kg
mm
m
m
m
m
Inches
Inches
WORLD
ARMOIRES
DUO DELTA DC INVERTER SERIES
Accessory
Mounting bracket
• Part number
49
R22 range
WORLD
50
range
electra 2007 air conditioning catalogue
wall mounted
COMPACT F
WMZ/WNG
52
54
FLOOR / CEILING
56
WORLD
PXD
CASSETTES
ECF/ECF XL 58
dUCTED
LS EMDB 60
62
MULTISPLITS
DUO
63
51
Wall mounted
COMPACT F
Product benefits
New design with flat panet grill
Compact and lightweight for easy installation and maintenance
● 2 ventilation speed plus automatic speed
● Cold/hot Automatic regulation
● Automatic vertical treated air sweeping
● High efficiency filtration
●
●
Wall mounted range*
: COMPACT F
WMZ/WNG
COMPACT F 7/9/12/18
OU COMPACT 7/9 RC
RC5 Remote control
Accessories
Mounting bracket
52
• Part number
COMPACT F7
7ACTL0016
COMPACT F9
7ACTL0016
COMPACT F12
7ACTL0016
COMPACT F18
7ACTL0018
electra 2008 air conditioning & HEATING catalogue
4 Heat Pump models R22: from 2 150 to 5 500 W
COMPACT F 7 RC
COMPACT F 9 RC
2,12
0,73
2,9/C
2,6
3,2
0,97
1,15
2,68/D
2,78/D
v10 °/46 ° Dry Bulbk
5,1
1,93
2,64/D
2,15
0,69
3,12/D
2,8
3,5
0,89
1,06
3,15/D
3,3/D
v9 °/24 ° Dry Bulbk
5,55
1,9
2,92/D
dB(A)
dB(A)
m3/h
l/h
mm
kg
31/37
45/50
320/400
0,7
680x180x250
7
ESP022408
35/40
48/52
350/450
1,0
680x180x250
7
ESP022409
33/40
47/53
460/620
1,05
840x180x250
8
ESP022410
35/44
450/670
2,2
900x200x295
12
ESP022411
dB(A)
dB(A)
m3/h
52
62
1200
Rotary
610x240x520
23
7002350
52
62
1265
Rotary
610x240x520
27
ESP061674
54
65
1200
Rotary
610x240x520
29
ESP061675
49
Rotary
795x290x610
42
ESP061561
Linking specifications between indoor and outdoor units
Power supply 1~230 V
Power supply side
Indoor
Power cable section
mm2
3x1,5
Fuse rating am
A
10
Electrical connections Indoor/Outdoor
mm2
4x1
Electrical connections
mm2
5x1
Indoor
3x1,5
10
4x1
5x1
Indoor
3x1,5
16
4x1,5
5x1,5
Indoor
3x1,5
16
4x1,5
5x1,5
Linking pipes
Max. lenght
Max. height
Suction pipe diameter
Liquid pipe diameter
12
7
3/8”
1/4”
15
7
1/2”
1/4”
15
7
1/2”
1/4”
Cooling Capacity
Power Input
EER/Energy Label
Outdoor temperature operating limits
Heating Capacity
Power Input
COP/Energy Label
Out. temperature operating limits
Indoor units
Sound pressure level to 1 m (LS/HS)
Sound power level
Airflow (LS/HS)
Dehumidification
Dimensions (WxDxH)
Weight
• Part number
Outdoor units
Sound pressure level to 1 m
Sound power level
Airflow
Compressor type
Dimensions (WxDxH)
Weight
• Part number
kW
kW
°C
kW
kW
°C
mm
kg
m
m
Inches
Inches
10
7
3/8”
1/4”
COMPACT F 12 RC COMPACT 18 RC
R407C/R22
COMPACT F SERIES
53
Wall mounted
WMZ / WNG
WMZ Product benefits
Automatic vertical treated air sweeping.
High filtration.
● Compact
and lightweight for easy installation and maintenance.
● Two
fan speed.
● Slow
down at night.
● Airconet
compatible system.
●
●
Indoor unit WMZ
RCW2 Remote control (accessory)
RC5 Remote control
• Part number 7ACEL1212
Wall mounted range*
: COMPACT
WMZ/WNG
*Others models available in Europe range
WNG Product benefits
Automatic vertical treated air sweeping.
LCD screen.
● ESF
model : ioniser and pre-filter.
●
●
WNG 30 RC
54
OU WNG 30
EUROPE
AMBIANCE
electra 2008 air conditioning & HEATING catalogue
WMZ / WNG SERIES
WMZ 24 RC
WNG 30 RC
Cooling Capacity
Power Input
EER/Energy Label
kW
kW
6.54
2.33
2.8/D
8.5
3.1
2.74/D
Heating Capacity
Power Input
COP/Energy Label
kW
kW
7.2
2.66
2.70/E
9.5
3.25
2.02/D
m3/h
l/h
dB(A)
kg
mm
690/990
2.6
44/50
14
1115x200x330
ESP022244
830/1250
41/54
18.5
1280x340x236
7001646
Rotary
2480
61
62
846x302x690
7002367
Scroll
1300
49
84
900x340x970
854549
Linking specifications between indoor and outdoor units
Power supply 1~230 V
Power supply side
Fuse rating am
A
Electrical connections Ind./Out.
mm2
Indoor
20
5x2.5
Outdoor
32
6x1.5
Linking pipes
Max. lenght
Max. height
Suction pipe diameter
Liquid pipe diameter
15
7
5/8”
1/4”
25
15
5/8”
3/8”
Indoor units
Air flow (LS/HS)
Dehumidification
Acoustic pressure to 1 m (LS/HS)
Weight
Dimensions (WxDxH)
• Part number
Outdoor units
Compressor type
Air flow
Acoustic pressure to 1 m
Weight
Dimensions (WxDxH)
• Part number 1~230 V
m3/h
dB(A)
kg
mm
m
m
Inches
Inches
WORLD
ARMOIRES
2 Heat Pump models R22 : from 7 200 to 9 500 W
55
PXD
Floor/Ceiling
Product benefits
Ceiling or low wall mounting.
Automatic horizontal and vertical sweeping of air treated.
● Compact
and light for easy installation and maintenance.
● Possibility
of air conditioning two rooms with a single unit.
●
●
Floor ceiling range*
: PXD
*Others models available in Europe range
PXD 9/12/18
PXD 24/30
OU 9/12/18
RC4 Remote control
RCW2 Remote control (accessory)
• Part number 7ACEL1212
Accessories
Single phase electric heating
Single phase electric heating
Three phases electric heating
Condensate lift pump
Air distribution unit
Rear panel tube cover (ceiling mounting)
Mounting bracket
56
Capacity (W)
• Part number
Capacity (W)
• Part number
Capacity (W)
• Part number
• Part number
• Part number
• Part number
• Part number
PXD 9
1250
7ACEL1153
7ACFH0221
7ACVF0122
7ACTL0073
7ACTL0016
PXD 12
1250
7ACEL1153
1000
7ACEL1172
7ACFH0221
7ACVF0122
7ACTL0073
7ACTL0016
PXD 18
2000
7ACEL1154
7ACFH0221
7ACVF0122
7ACTL0073
7ACTL0018
PXD 24
3000
7ACEL1155
1500
7ACEL1173
3000
7ACEL1156
7ACFH0221
7ACVF0123
7ACTL0074
7ACTL0018
PXD 30
3000
7ACEL1155
1500
7ACEL1173
3000
7ACEL1156
7ACFH0221
7ACVF0123
7ACTL0074
7ACTL0018
EUROPE
AMBIANCE
electra 2008 air conditioning & HEATING catalogue
5 Heat Pump models R22 : from 2 700 to 8 420 W
PXD SERIES
PXD 9 RC
Cooling Capacity
Power Input
EER/Energy Label
Out. temperature operating limits
kW
kW
Heating Capacity
Power Input
COP/Energy Label
Out. temperature operating limits
kW
kW
Indoor units
Dehumidification
Air flow (LS/NS/HS)
Acoustic pressure to 1 m (LS/NS/HS)
Weight
Dimensions (WxDxH)
• Part number
• Part number with rotary (1)
°C
°C
PXD 18 RC (1)
PXD 24 RC (1)
PXD 30 RC
2.64
1.07
2.47/E
3.52
1.36
2.59/E
fl21 °/46 ° Dry Bulb‡
5.42
1.92
2.83/C
7.12
2.58
2.76/D
8.8
3.68
2.4/F
2.7
1
2.52/F
3.52
1.28
2.59/F
fl-9 °/24 ° Dry Bulb‡
5.85
2.15
3.05/D
7.46
2.6
2.89/D
8.42
3.24
2.29/G
1.5
350/390/420
38/41/45
21
820x190x630
ESP012126
-
2.4
460/515/560
40/44/48
23
820x190x630
ESP012128
ESP012149
2.5
700/820/930
44/48/52
29.5
1200x190x630
ESP012129
ESP012129
740/895/1020
45/51/54
32
1200x190x630
ESP012130
-
Rotary
dB(A) 42
kg
31
mm 760x245x545
7001883
-
Rotary
43
37
760x245x545
7001856
-
Scroll
47
56
846x302x690
7853672
7001314
Scroll
47
58
846x302x690
7853670
7001312
Scroll
49
84
900x340x860
854549
-
Linking specifications between indoor and outdoor units
Power supply 1~230 V
Power supply side
Indoor
Power cable section (without heating) mm2 3x1.5
Fuse rating am
A
10
Electrical connections Ind./Out.
mm2 5x1
Indoor
3x1.5
16
5x1.5
Ind. or Out.
3x2.5
20
6x2.5*
Ind. or Out.
3x2.5
20
6x2.5*
Outdoor
3x4
25
6x1.5
Power supply 3N~400 V
Power supply side
Power cable section (without heating) mm2
Fuse rating am
A
Electrical connections Ind./Out.
mm2
-
-
Outdoor
5x1.5
3x6
6x1.5
Outdoor
5x1.5
3x8
6x1.5
Outdoor
5x1.5
3x10
6x1.5
Linking pipes
Max. lenght
Max. height
Suction pipe diameter
Liquid pipe diameter
15
7
3/8”
1/4”
15
7
1/2”
1/4”
25
10
5/8”
3/8”
15
7
5/8”
3/8”
30
10
5/8”
3/8”
m
m
Inches
Inches
WORLD
ARMOIRES
1
290/330/350
35/37/38
21
820x190x630
ESP012125
-
Outdoor units
Compressor type
Acoustic pressure to 1 m
Weight
Dimensions (WxDxH)
• Part number 1~230 V
• Part number with rotary (1)
l/h
m3/h
dB(A)
kg
mm
PXD 12 RC
* In the case of connections to an indoor unit.
57
Cassettes
ECF & ECF XL
Product benefits
Four motorised treated air blowing flaps.
Flush fitting into a suspended ceiling.
● 600x600
format (ECF)/900X900 (ECF XL).
● Air
distribution in 2, 3 or 4 directions.
● Flush
fitting : 287 mm (ECF); 230 mm (ECF XL).
● New
air intake.
● Integrated
condensate drainage lift pump.
●
●
Cassette range*
: ECF/ECFXL
*Others models available in Europe range
RC3 Remote control
Indoor unit ECF XL 30/36/45
Indoor unit ECF 9/11/15/18/24
Outdoor unit
RCW2 Remote control (accessory)
OU 36/45
• Part number 7ACEL1212
Models available with Rotary compressor (1)
Indoor units
Outdoor units
• Part number
• Part number
ESP042129
7001314
• Part number
• Part number
• Part number
• Part number
ECF 9 LV
7ACVF0091
7ACTL0016
7ACFH0077
-
ESP042111
7001312
Accessories
Adapter Frame solid cellings
Mounting bracket
All seasons kit
Frame 900x900
58
ECF 11 LV
7ACVF0091
7ACTL0016
7ACFH0077
-
ECF 18 LV/R
7ACVF0091
7ACTL0018
7ACFH0077
-
ECF 24 LV/R
7ACVF0091
7ACTL0018
7ACFH0077
-
ECFXL 30RC
7ACTL0018
7ACFH0078
EACVF002
ECFXL 36RC
7ACTL0013
EACVF002
ECFXL 45RC
7ACTL0013
EACVF002
electra 2008 air conditioning & HEATING catalogue
ECF SERIES
ECF 9 LV
ECF 11 LV ECF 18 LV(1) ECF 24 LV(1) ECF XL 30RC ECF XL 36RC ECF XL 45RC
2.65
1.1
2.41/E
3.22
1.05
3.1/B
5.7
1.93
2.95/C
6.8
8.3
2.63
3.16
2.6/D
2.62/D
fl10 °/46 ° Dry Bulb‡
9.9
3.65
2.71/D
11.5
4.6
2.5/E
2.98
0.97
3.07/E
3.3
0.97
3.4/C
5.8
2.04
2.84/D
7.2
10.2
2.67
3.37
2.7/E
3.02/D
fl-9 °/24 ° Dry Bulb‡
11.3
3.65
3.1/D
13.5
4.7
2.87/D
430/470/600
33/35/42
16
26
571x571x287
625x625x40
ESP042107
-
375/500/550
33/37/42
16
26
571x571x287
625x625x40
ESP042108
-
530/640/760
33/37/40
16
26
571x571x287
625x625x40
ESP042110
ESP042129
590/660/760
37/41/45
16
30
571x571x287
625x625x40
ESP042111
ESP042111
985/1120/1200
47/50/52
42
840x840x230
950x950x46
ESP042113
-
1025/1125/1220
42/44/46
48
840x840x300
950x950x46
ESP042114
-
1200/1330/1525
45/47/50
48
840x840x300
950x950x46
ESP042115
-
Rotary
41
31
760x245x545
7001883
-
Rotary
42
37
760x245x545
7001856
-
Scroll
47
56
850x370x690
7853672
7001314
-
Scroll
47
58
850x370x690
7853670
7001312
-
Scroll
62
87
950x412x835
854549
-
Scroll
62
92
950x412x835
854372
854373
Scroll
56
120
950x412x1260
854375
Linking specifications between indoor and outdoor units
Power supply 1~230 V
Power supply side
Indoor
Power cable section (without heating)
mm2
3x1.5
Fuse rating am
A
10
Electrical connections
mm2
5x1.5
Indoor
3x1.5
16
5x1.5
Ind. or Out.*
3x2.5
20
6x2.5*
Ind. or Out.*
3x2.5
20
6x1.5*
Outdoor
3x4
25
6x2.5
-
-
Power supply 3N~400 V
Power supply side
Power cable section (without heating)
Fuse rating am
Electrical connections
mm2
A
mm2
-
-
Outdoor
5x1.5
3x6
6x1.5
Outdoor
5x1.5
3x10
6x1.5
Outdoor
5x2.5
3x16
6x1.5
Outdoor
5x2.5
3x16
6x2.5
Outdoor
5x2.5
3x16
6x2.5
Linking pipes
Max. lenght
Max. height
Suction pipe diameter
Liquid pipe diameter
m
m
Inches
Inches
15
7
3/8”
1/4”
15
7
1/2”
1/4”
25
10
5/8”
3/8”
25
10
5/8”
3/8”
30
15
5/8”
3/8”
50
25
3/4”
3/8”
50
25
3/4”
3/8”
Cooling Capacity
Power Input
EER/Energy Label
Out. temperature operating limits
kW
kW
Heating Capacity
Power Input
COP/Energy Label
Out. temperature operating limits
kW
kW
Indoor units
Air flow (LS/MS/HS)
Acoustic pressure to 1 m (LS/MS/HS)
Condensate drainage pipe (diam.)
Weight
Flush mounted indoor unit (WxDxH)
Frame (WxDxH)
• Part number
• Part number with Rotary (1)
°C
°C
m3/h
dB(A)
mm
kg
mm
mm
Outdoor units
Compressor type
Acoustic pressure to 1 m
dB(A)
Weight
kg
Dimensions (WxDxH)
mm
• Part number 1~230 V
• Part number 1-230 V with Rotary (1)
• Part number 3N~400 V
* In the case of connection to an indoor unit.
59
WORLD
7 Heat Pump models R22: from 2 980 to 13 500 W
LS
Ducted
Product benefits
Suspended ceiling installation.
Horizontal or vertical mounting (models 35/45/55/65/85/90).
● Horizontal
mounting only (model 105).
● Low
built in height (300 mm).
● Pressure
available for connection to a duct network.
● Sets
of accessories for air intake and distribution via ducts or grilles.
●
●
Ducted range*
: LS
EMD B
*Others models available in Europe range
Indoor unit LS
Outdoor unit
RCW2 Remote control (accessory)
RC4 Remote control
• Part number 7ACEL1212
Models available with Rotary compressor 1~230 V (1)
Indoor units
Outdoor units
• Part number
• Part number
LS 55 RC/R
ESP022316
7001314
LC 65 RC/R
ESP022222
7001312
Accessories
LS 35 RC
N°1 cassette air intake plenum kit • Part number 7ACVF0075
N°2 duct connection plenum kit • Part number 7ACVF0073
Kit electric heating
• Part number 7ACEL1305
60
LS 55 RC/R
7ACVF0075
7ACVF0073
7ACEL1306
LS 65 RC/R
7ACVF0076
7ACVF0074
7ACEL1259
LS 85 RC
7ACVF0076
7ACVF0074
7ACEL1259
LS 85 RC
7ACVF0076
7ACVF0074
7ACEL1259
LS 90 RC
-
LS 105 RC
7ACEL1267
electra 2008 air conditioning & HEATING catalogue
6 Heat Pump models R22 : from 3 200 to 11 000 W
LS 35 RC
LS 55 RC (1)
LS 65 RC (1)
3.20
1.05
3.05/B
5.52
1.9
2.91/C
6.70
2.7
2.48/E
3.20
0.96
3.33/C
6.08
1.94
3.13/D
7.30
2.55
2.86/D
360/450/580
3.2/3.8/4.3
35
30
860x680x245
ESP022219
660/710/800
3/3.5/4
49
31
860x680x245
ESP022221
910/1035/1120
2.4/3.2/4
41
37
1190x675x270
ESP022222
Rotary
43
37
760x245x545
7001856
-
Scroll
47
56
850x370x690
7853672
-
Linking specifications between indoor and outdoor units
Power supply 1~230 V
Power supply side
Indoor
Power cable section (without heating) mm2 3x1.5
Fuse rating am
A
16
Electrical connections Ind./Out.
mm2 5x1.5
Power supply 3N~400 V
Power supply side
Power cable section (without heating) mm2
Fuse rating am
A
Electrical connections Ind./Out.
mm2
Linking pipes
Max. lenght
Max. height
Suction pipe diameter
Liquid pipe diameter
Cooling Capacity
Power Input
EER/Energy Label
Out. temperature operating limits
Heating Capacity
Power Input
COP/Energy Label
Out. temperature operating limits
Indoor units
Air flow (LS/MS/HS)
Available static pressure (LS/MS/HS)
Acoustic pressure to 1 m (LS/NS/HS)
Weight
Dimensions (WxDxH)
• Part number
kW
kW
LS 90 RC
LS 105 RC
8.50
3.5
2.43/E
fl21 °/46 ° Dry Bulb‡
9.00
3.3
2.69/D
10.26
3.8
2.67/D
9.01
3.48
2.59/F
fl-9 °/24 ° Dry Bulb‡
9.43
3.07
3.07/D
11
3.84
2.86/D
940/1150/1230
2/3/4
54.5
37
1190x675x270
ESP022223
1175/1380/1535
3.7/7
54.5
31
930x475x300
854387
1175/1380/1535
3.7/7
54.5
38
1100x475x300
ESP022252
Scroll
47
58
850x370x690
7853670
-
Scroll
62
82
900x340x860
854549
-
Scroll
80
900x340x860
854549
-
Scroll
62
93
900x340x970
854372
854373
Ind. or Out.
3x2.5
20
6x2.5*
Ind. or Out.
3x2.5
20
6x2.5*
Outdoor
3x4
25
6x2.5*
-
-
-
Outdoor
5x1.5
3x10
6x1.5
Outdoor
5x1.5
3x10
6x1.5
Outdoor
5x2.5
3x12
6x1.5
Outdoor
5x2.5
3x16
6x1.5
Outdoor
5x1.5
3x16
6x1.5
15
7
1/2”
1/4”
25
10
5/8”
3/8”
25
10
5/8”
3/8”
30
10
5/8”
3/8”
30
10
5/8”
3/8”
50
25
3/4”
3/8”
°C
kW
kW
°C
m3/h
daPa
dB(A)
kg
mm
Outdoor units
Compressor type
Acoustic pressure to 1 m (LS/NS/HS) dB(A)
Weight
kg
Dimensions (WxDxH)
mm
• Part number 1~230 V
• Part number 3N~400 V
m
m
Inches
Inches
LS 85 RC
WORLD
LS SERIES
61
Ducted
EMDB
Product benefits
Scroll Compressor.
Air pressure available for duct network.
● Suspended
ceiling installation.
● Humidity
control.
● Airconet
connection (options).
●
●
Ducted range
: LS
EMD B
Others models available in Europe range
Indoor unit EMDB 1450
2 Heat Pump models R22: from 13 750 to 15 820 W
EMDB SERIES
EMDB 1450 RC
Cooling Capacity
Power Input
EER
Outdoor temperature operating limits
kW
kW
Heating Capacity
Power Input
COP
Outdoor temperature operating limits
kW
kW
Indoor unit
Air flow (HS)
Acoustic pressure to 1 m (LS/MS/HS)
Weight
Dimensions (WxDxH)
• Part number
Outdoor unit
Compressor type
Weight
Dimensions (WxDxH)
• Part number 3N~400 V
13.48
5.18
2.6
15.82
5.99
2.64
M21 °/46 ° Dry BulbC
13.75
4.44
3.1
15.82
5.125
3.1
M-9 °/24 ° Dry BulbC
°C
°C
m3/h
dB(A)
kg
mm
kg
mm
EMDB 1800 RC
2120
49/52/55
42
1093x620x435
ESP022319
2830
52/56/60
46
1140x680x400
ESP022320
Scroll
95
900x340x970
853699
Scroll
110
900x340x1250
820293
Linking specifications between indoor and outdoor units
Power supply 3N~400 V
Power cable section (without heating)
mm2
5x2.5
Fuse rating am
A
3x20
Electrical connections
mm2
6x1.5
5x2.5
3x20
6x1.5
Linking pipes
Max. lenght
Max. height
Suction pipe diameter
Liquid pipe diameter
50
25
7/8”
1/2”
62
m
m
Inches
Inches
50
25
3/4”
3/8”
RC3 Remote control
OU EMDB 1800
electra 2008 air conditioning & HEATING catalogue
Multisplits
DUO
Product benefits
Rotary Compressor.
Possibility of air conditioning two separate rooms with a single unit.
● Compatible
with WMZ, PXD, ECF and LS indoor units.
●
●
Multisplit range
: DUO
DUO available on request between 8 and 13 KW
OU DUO
DUO SERIES
DUO 7/7 RC
DUO 9/9 RC
DUO 9/12 RC
DUO 12/12 RC
Cooling Capacity
Power Input
EER/ Energy Label
kW
kW
4.2 (2x2.1)
1.7
2.47/E
5.2 (2x2.6)
2.02
2.57
5.9 (2.6 + 3.3)
2.83
2.08
6.6 (2x3.3)
2.72
2.57
Heating Capacity
Power Input
COP/ Energy Label
kW
kW
4.4 (2x2.2)
1.44
3.06/D
5.4 (2x2.8)
1.96
2.76/E
5.9 (2.6 + 3.3)
2.33
2.53/F
7 (2x3.5)
2.78
2.52/F
dB(A)
49
Rotary
52
850x370x690
7001751
53
Rotary
60
850x370x690
7001831
53
Rotary
62
850x370x690
7001830
57
Rotary
64
850x370x690
7001863
Linking specifications between indoor and outdoor units
Power supply 1~230 V
Power supply side
Outdoor
Fuse rating am
mm2
10
Electrical connections
mm2
2x (6x1.5)
Outdoor
16
2x (6x1.5)
Outdoor
20
2x (6x1.5)
Outdoor
10
2x (6x1.5)
Linking pipes
Max. lenght
Max. height
Suction pipe diameter
Liquid pipe diameter
2x15
2x6
2x3/8”
2x1/4”
2x15
2x6
1/2” + 3/8”
2x1/4”
2x15
2x6
2x1/2”
2x1/4”
Outdoor unit
Noise level
Compressor type
Weight
Dimensions (WxDxH)
• Power supply 1~230 V - Part number
kg
mm
m
m
Inches
Inches
2x15
2x6
2x3/8”
2x1/4”
WORLD
4 Heat Pump models : from 4 400 to 7 000 W
63
electra 2008 air conditioning & HEATING catalogue
WORLD
Notes
64
Download PDF