Split, Multi and VRF systems Air conditioning Residential and Light Commercial Systemair Trust We consider your trust in us as a supplier an important goal. It is always included in our work on all levels and in all areas whether it is a question of cooperation, quality, deliveries or documentation. This catalogue is of course a part of this work. With this catalogue, which features products of air conditioning, we want to give you as a customer a general overview of what Systemair can offer within this field. More detailed information is available in our Online catalogue at www.systemair.com and as downloadable software. Systemair’s range of fans, air distribution products and accessories also appears in our printed main catalogue. Our product development leads the field - latest technologies in unitdesign, fans, motors, heat recovery, chillers, fan coils,... interact to give high efficiency and with that low power consumption. Systemair has grown each year since the start and we aim to continue with this trend. Systemair strives to be a reliable supplier of quality products. We help our customers to focus on their own business. Reliable deliveres give the customers greater possibilities to quickly complete a job, and move on to the next project. At Systemair we call this Trust. © Systemair 2013. Systemair reserves the right to make technical changes. For updated documentation, please refer to www.systemair.com Content | Content Systemair 4 Product Range 6 Application 8 SPLIT systems 10 Wall-mounted series 14 Multi systems 20 Light-commercial series 32 VRF systems 40 Outdoor units 44 Indoor units 60 Ventilation application Controls and accessories 80 84 3 4 | Systemair Systemair worldwide Skinnskatteberg, Sweden: Windischbuch, Germany: Ukmerge, Lithuania: Systemair AB, the Systemair group head office is in Skinnskatteberg, Sweden. The production is virtually fully automated with modern machinery featuring advanced computer support. Also located here is the company’s most advanced test installation for measuring technical data. Production facility for fans and modular air handling units, specialized on engineered products (e.g. tunnel and jet fans). Distribution center. Production of smaller air handling units with energy recovery systems. Klockgården, Sweden: Hässleholm, Sweden: Systemair’s small air handling units are manufactured at Klockgården in Skinnskatteberg. Frico’s central warehouse of approximately 8000 m2 is also located here. Langenfeld, Germany: Production of air curtains. VEAB is the leading European manufacturer of electric duct heaters. Production of heating and cooling coils, electric and water based. Maribor, Slovenia: Specialized in centrifugal smoke extract fans, EN certified. Hasselager, Denmark: Production of modular air handling units. Dal Eidsvoll, Norway: Production of air handling units. Systemair | Save energy, lower running cost! Quality: Systemair is certified in accordance with ISO 9001; ISO 14001 and ATEX. Our research and development laboratories are one of the most modern in Europe; measurements are made in accordance with international standards like AMCA and ISO. Dal, Eidsvoll, Norway Hasselager, Denmark Bouctouche, Canada Kansas City, USA Waalwijk, Netherlands Windischbuch, Germany Tillières-sur-Avre, France Barlassina, Italy Madrid, Spain Our label “Green Ventilation” features products with a high energy saving potential. All products labelled with “Green Ventilation” combine energy economy with energy efficiency. Skinnskatteberg, Sweden Hässleholm, Sweden Ukmerge, Lithuania Langenfeld, Germany Bratislava, Slovakia Maribor, Slovenia Istanbul, Turkey New Delhi, India Hyderabad, India Kuala Lumpur, Malaysia Bratislava, Slovakia: New Delhi, India: Kansas City, USA: The factory in Bratislava manufactures air distribution products and EN certified fire and smoke dampers. The factories in New Delhi and Noida manufacture grilles and diffusers. Production of fans for the US market. Kuala Lumpur, Malaysia: Barlassina, Italy: Systemair-HSK is Turkey‘s leading manufacturer of air handling units. Production and marketing of products for Tunnel and garage ventilation. Our factory in Italy, Systemair, develops and manufactures a wide range of chiller and heat pump in A class from 20 to 1.600kW. Madrid, Spain: Bouctouche, Canada: Production of air handling units for the southern European market. Hyderabad, India: Production if air distribution products. 5 Our main North American production facility of air handling units and inline fans for commercial and residential applications is located in Bouctouche. Istanbul, Turkey: Waalwijk, Netherlands: Holland Heating is Netherlands leading manufacturer of air handling units. Tillières-sur-Avre, France: Our factory in Italy, Systemair, develops and manufactures: Roof top, water source heat pump, hight temperature heat pump, water terminals. 6 | Product range Product range Systemair has an extensive range of ventilation products: fans including smoke extract, tunnel and car park fans, explosion proof fans, air handling units from large central units to small residential units with energy recovery, air distribution products and fire dampers. These products are installed in a variety of locations, including homes, offices, healthcare premises, shops, industrial buildings, tunnels, parking garages, training facilities, sports centres etc. Fans Duct fans Rectangular duct fans Systemair has the wider range of fans for use in different applications. Our range includes any type of fans, from circular ducts – hystorical product – boxed up to those of extraction, axial, and explosion-proof for the extraction of fumes. All products listed above are made in different dimensions from 100 mm in diameter to fans of large size for tunnel. All our fans are designed to meet the strict requirements, easy to use, high quality and durability. Duct fans for circular duct installation. Duct fans with rectangular connection. Centrifugal fans Centrifugal supply single fans. Square duct fans For different applications, there are models for ambient with high temperature. Axial fans Axial fans for duct or wall application. Roof fans Roof fans with circular or square connection. Jet Axial Fans Jet Axial Fans for car park, tunnels and air overpression. High temperature fans Systemair provides high fire resistance fans till 600°C/2 hours. Explosion proof fans Explosion proof fans in duct, roof or wall design. Product range | Air handling units Systemair produces a wide range of air handling units for several applications, from small office to large industrial building. All range is been developped to satisfy strict needs of low energy consumption. Fire and smoke dampers Smoke extract fans High efficient fans to extract the combustion smoke. Fire & smoke dampers Dampers that reduce the spread of smoke and fire. Residential ventilation Residential units Cooker hoods Complete energy-efficient air handling units with heat recovery and built in control systems. Designed to be mounted over the cooker, on walls or horizontally in attics. For homes with living areas of 60320 m 2. Ideal for capturing odours even at low airflows. Air distribution products Supply, extract & transfer devices For mounting in ceilings or walls. Nozzle diffusers Optimum flexibility and comfort in air distribution for rooms. The range also includes a wide selection of air distribution products and accessories. Air Conditioning The strengh point of Systemair Air Conditioning products is a wide range with several options and accessories: chiller, water terminals, close control etc. 7 Applications Schools In buildings for school, the load to be disposed is variable during the day due to the presence of people only for some periods, thus it is mandatory to control the users requirements during daily plant use. Systemair offers a wide range of equipment suitable for this purpose, the fan coils with EC motors allow to obtain the required flexibility. Offices In buildings for tertiary application, the air conditioning and the ventilation are necessary during the day. The heat loads to be removed are generally generated by people present, from the lighting system, from solar radiation and by machines. Normally it is necessary the use of chillers, Heat Pump to produce cold and/or hot water to be sent to hydronic (fan coils, cassettes, ducted) to obtain an optimum air conditioning of offices. Commercial buildings Normally the number of people varies continuously; the optimal solution would be to use machinery for the conditioning with variable flow and with constant monitoring of concentration of pollutants (VOC and CO2). Systemair products can easily meet the plantʼs requirement . Industry Industrial plants generate a large amount of heat that must be dissipated in the appropriate way. Systemair offers a wide range of products (chillers from 20 kW to 1.680 kW) that can be readily integrated industrial installation. The chiller can be used both for air conditioning and for the cooling equipment process (production of chilled water up to -10°C). Hotels In the hotel rooms, it is needed a high level of comfort with the minimum impact with respect to the noise level. Systemair ducted products equipped with EC motors fully comply with requirements efficiency, cooling capacity and sound impact , required by this type of installations. SYSPLIT Split and Multi systems | SYSPLIT air conditioners Systemair: residential and light commercial split systems The SYSPLIT air conditioner range are specifically designed for small to medium sized areas, offering the end user improved comfort and reducing drastically the power consumption. The expanded range of SYSPLIT air conditioners is of superior performance and quality, providing more choice for customers. Our innovative products offer the ideal solution when you need quiet and efficient room air conditioning to create a comfortable environment. In addition to Single Split systems, Systemair also offers the SYSPLIT MULTI – an advanced range of inverter Heat Pump Multi Split Systems with up to 5 indoor units of different types that can be connected. All SYSPLIT inverter systems utilise the non-ozone depleting R410A refrigerant, which gives increased system performance, increased energy-efficiency and improved heat transfer, which results in smaller pipe sizes and more compact indoor units. The latest generation of SYSPLIT air conditioners are among the most technically advanced and energyefficient systems available today. SYSPLIT Single and Multi systems SYSPLIT WALL EVO PH 14 SYSPLIT MULTI rated capacity 25 SYSPLIT WALL EVO HP 16 SYSPLIT CASSETTE EVO HP 30 SYSPLIT WALL INV HP 18 SYSPLIT CEILING EVO HP 32 SYSPLIT MULTI EVO HP 20 SYSPLIT DUCT EVO HP 34 SYSPLIT MULTI combination 22 SYSPLIT DUCT HT 36 11 12 | Split and Multi systems Ecodesign regulation ErP Directive 2009/125 The new regulation have been adopted by the European Parliament to achieve the goals to reduce the power consumption in Europe related to air conditioning business and other home appliance as well as air-to-water heat pump, air handling, ventilation etc. With its strategic plan called “20/20/20”, Europe aims to reduce the CO2 emissions by 20%, using 20% more renewable energy and consuming 20% less primary energy by 2020. In order to facilitate the achievement of these objectives, EU issued the ErP Directive that specifies the eco-design 20% less emissions of CO2 gas requirements for placing on the market the energy-using products. For split air conditioners with power less than 12 kW, the minimum requirements are based on a new index of seasonal efficiency and on the sound power level as shown in the table below: A/C <6 kW SEER/SCOP min. SCOP SEER SCOP 4,6 3,8 4,3 3,8 Lw indoor max. 60 dB(A) 65 dB(A) Lw outdoor max. 65 dB(A) 70 dB(A) 20% more use of renewable energy Measuring the performance in real conditions The European Union requires the application of objective metrics for measuring performance in order to establish the minimum requirements and provide customers with information regarding the performance of air conditioning useful for their purchase. The methodology used up to 2012 and based on the efficiency rating (EER) – presents a significant difference between the predicted and actual performance. For this reason a more accurate method has beed designed: the seasonal efficiency ratio (SEER). A/C 6-12 kW SEER 20% less use of primary energy Among the most significant changes it includes the introduction of different operating temperatures for cooling and heating, the possibility of use of energy both at partial load and full load and power usage in standby and off mode. Considering that most systems operate mostly in partload conditions, the new methodology will allow to assess better the performance of a unit in real conditions. Split and Multi systems | New energy classification New energy classification in force from 1 January 2013 The transition to the concept of seasonal efficiency involves the development of a completely new energy label which shows the energy class based on the values of SEER and SCOP and the main characteristics of the product such as the sound power level of the indoor and outdoor units. Energy efficiency in heating is presented with three different values according to the climate where the product is installed. For the manufacturer of the product is mandatory to indicate the values for the Temperate climate (“Averge” heating value), those of the other two climates are optional. The data and energy efficiency classes are declared in accordance with EN14825. The energy class shown in the new label, both in cooling and in heating, can not be compared to the energy class that had the old energy label as the latter was based on specific indices (EER and COP) and not on seasonal indices SEER and SCOP. The energy efficiency classes for split air conditioners are shown in the table below: SEER SCOP A+++ Energy Efficiency Class SEER ≥ 8,50 SCOP ≥ 5,10 A++ 6,10 ≤ SEER < 8,50 4,60 ≤ SCOP < 5,10 A+ 5,60 ≤ SEER < 6,10 4,00 ≤ SCOP < 4,60 A 5,10 ≤ SEER < 5,60 3,40 ≤ SCOP < 4,00 B 4,60 ≤ SEER < 5,10 3,10 ≤ SCOP < 3,40 C 4,10 ≤ SEER < 4,60 2,80 ≤ SCOP < 3,10 D 3,60 ≤ SEER < 4,10 2,50 ≤ SCOP < 2,80 E 3,10 ≤ SEER < 3,60 2,20 ≤ SCOP < 2,50 F 2,60 ≤ SEER < 3,10 1,90 ≤ SCOP < 2,20 G SEER < 2,60 SCOP < 1,90 13 14 | Hi-wall Inverter Polar Split Hi-wall Inverter Polar Split SYSPLIT WALL EVO PH Features SYSPLIT WALL EVO PH assures superior performance even in harsh outdoor conditions with an unique and exclusive design. Advanced DC inverter control for the compressor, outdoor fan motor and indoor fan motor. Cooling and heating operation down to -20 °C outdoor temperature assures an operation all year round. Self-diagnosis function continuosly monitors the operation of the air conditioner and protects the system. Refrigerant leakage detection can prevent the compressor being damaged by refrigerant leakage or compressor overload. The active carbon filter ensures excellent performance to remove odours, pollen and ammonia. The heating belt fitted on the base plate of the outdoor unit avoids the accumulation of rain, snow or defrosted water. Hydrophylic aluminium fins of the indoor units improve the heat exchange efficiency in cooling and heating mode. The crankcase heater wrapped around the compressor eusares safe start at very low outdoor temperature. Power factor capacitors included in the outdoor unit allow an active PF around 97%. Infrared remote control SYSCONTROL RM 52 (standard) With the Auto-restart function the unit resumes with the same settings before the electric power failure. Environment friendly R410A refrigerant. Infrared remote control SYSCONTROL RM 52 included. Dimensions SYSPLIT WALL IN SYSPLIT WALL OUT D B A Air inlet B C C Air inlet A E Air outlet Model 09 12 18 24 Model 09 12 18 24 A 835 990 990 1.186 A 760 760 845 900 B 198 218 218 258 B 590 590 700 860 C 280 315 315 340 C 285 285 320 315 D 530 530 560 590 E 290 290 335 333 Hi-wall Inverter Polar Split | Technical features Model Indoor unit SYSPLIT WALL IN 09 EVO PH Q IN 12 EVO PH Q IN 18 EVO PH Q IN 24 EVO PH Q Model Outdoor unit SYSPLIT WALL OUT 09 EVO PH Q OUT 12 EVO PH Q OUT 18 EVO PH Q OUT 24 EVO PH Q Art. no. Indoor unit 314055 314265 314266 314267 Art. no. Outdoor unit 314268 314269 314270 314271 R410A / 1,1 R410A / 1,15 R410A / 1,15 R410A / 2,2 kW 2,90 (1,24-4,06) 3,69 (1,71-5,17) Power consumption W 810 (125~1.560) Operating current A Refrigerant / Charged quantity Power supply kg V/Ph/Hz Cooling capacity 220-240/1/50 5,28 (1,94-6,23) 7,33 (3,48-8,09) 1.048 (173~1.990) 1.640 (147~2.394) 2.102 (297~3.111) 3,10 (0,54~6,79) 4,35 (0,75~8,65) 6,77 (0,64~10,4) 9,62 (1,29~13,5) EER 3,58 3,52 3,22 3,49 SEER 6,9 7,0 6,9 7,1 Energy label cooling A++ A++ A++ A++ 5,86 (1,55-6,59) 8,50 (2,77-8,72) Heating capacity kW 2,93 (1,02-4,25) 3,87 (1,32-5,61) Power consumption W 620 (169~1.520) 983 (233~2.000) Operating current A 1.420 (270~2.355) 1.755 (417~3.115) 2,95 (0,73~6,6) 3,56 (1,01~8,71) 7,4 (1,17~10,2) 8,03 (1,8~13,5) COP 4,73 3,94 4,13 4,84 SCOP (Average) 4,1 4,1 4,0 4,1 Energy label heating A+ A+ A+ A+ Indoor Unit m3/h 630/490/380 820/670/560 1.090/830/690 1.300/1.210/990 Sound pressure level (H/M/L) dB(A) 41/33/25 44/38/31 47/40/31 49/43/37 Sound power level (H) dB(A) 54 55 57 61 Air flow rate (H/M/L) Dimensions LxWxH mm 835x198x280 990x218x315 990x218x315 1.186x258x340 Packing LxWxH mm 910x270x355 1.065x300x400 1.065x300x400 1.265x420x340 9/11 11,5/14 12/15 17,5/22 Net/gross weight kg Outdoor Unit Compressor Type Rotary Twin-rotary Sound pressure level (H) dB(A) 42 44 48 49 Sound power level (H) dB(A) 59 61 65 66 Dimensions LxWxH mm 760x285x590 760x285x590 845x320x700 900x315x860 Packing LxWxH mm 887x355x645 887x355x645 965x395x755 1.043x395x915 Net/gross weight Piping diameters 35/37 35/38 47/50 60/64 Liquid mm (inch) kg 6,35 (1/4”) 6,35 (1/4”) 6,35 (1/4”) 9,52 (3/8”) Gas mm (inch) 15,9 (5/8”) 9,52 (3/8”) 9,52 (3/8”) 12,7 (1/2”) mm 16 16 16 16 Max. input current A 9,5 11,5 14,0 16,0 Maximum lenght of the line m 25 25 30 50 Maximum height difference m 10 10 20 25 Indoor temperature °C +17…+32 cooling / heating 0 … +30 Outdoor temperature °C -20 ... +50 cooling / heating -20 ... +30 Drainage Nominal conditions Indoor unit Outdoor unit Piping lenght Level difference Cooling mode 27°C DB, 19°C WB 35°C DB 5m 0m Heating mode 20°C DB, 19°C WB 7°C DB, 6°C WB 5m 0m Seasonal efficiency according to EN 14825. The sound pressure value may vary depending on ambient conditions. 15 16 | Hi-wall Inverter High efficiency Split Hi-wall Inverter High efficiency Split SYSPLIT WALL EVO HP Features SYSPLIT WALL EVO HP combines cutting-edge technology with elegant and smooth shapes which can fit any interior decor, providing seasonal performance up to 7,0 (SEER). Advanced DC inverter control for the compressor, outdoor fan motor and indoor fan motor. Cooling and heating operation down to -15 °C outdoor temperature assures an operation all year round. Self-diagnosis function continuosly monitors the operation of the air conditioner and protects the system. Refrigerant leakage detection can prevent the compressor being damaged by refrigerant leakage or compressor overload. The cold catalyst filter effectively decomposes volatile compounds and it has anti-bacteria effect. It is washable and maintains the effect for long time. With Turbo mode the unit will run with the ultra-high speed for 20 minutes, reaching more quickly the setpoint temperature. Hydrophylic aluminium fins of the indoor units improve the heat exchange efficiency in cooling and heating mode. Power factor capacitors included in the outdoor unit allow an active PF around 97%. Infrared remote control SYSCONTROL RM 52 (standard) With the Auto-restart function the unit resumes with the same settings before the electric power failure. Environment friendly R410A refrigerant. Infrared remote control SYSCONTROL RM 52 included. Dimensions SYSPLIT WALL IN SYSPLIT WALL OUT D B A Air inlet B C C Air inlet A E Air outlet Model 09 12 18 24 Model 09 12 18 24 A 835 835 990 1.186 A 780 810 810 845 B 198 198 218 258 B 540 558 558 700 C 280 280 315 340 C 250 310 310 320 D 549 549 549 560 E 276 325 325 335 Hi-wall Inverter High efficiency Split | Technical features Model Indoor unit SYSPLIT WALL IN 09 EVO HP Q IN 12 EVO HP Q IN 18 EVO HP Q IN 24 EVO HP Q Model Outdoor unit SYSPLIT WALL OUT 09 EVO HP Q OUT 12 EVO HP Q OUT 18 EVO HP Q OUT 24 EVO HP Q Art. no. Indoor unit 314017 314018 314019 314167 Art. no. Outdoor unit 314004 314005 314006 314007 R410A / 1,03 R410A / 1,03 R410A / 1,65 R410A / 1,95 kW 2,78 (1,28~3,54) 3,66 (1,31~4,76) Power consumption W 803 (113~1.360) 1.071 (99~1.830) 1.670 (147~2.390) 2.147 (195~2.850) Operating current A Refrigerant / Changed quantity Power supply kg V/Ph/Hz Cooling capacity 220-240/1/50 5,28 (1,93~6,23) 6,45 (2,22~7,42) 3,49 (0,49~5,91) 4,66 (0,43~7,96) 7,26 (0,64~10,41) 9,45 (0,85~12,4) EER 3,47 3,42 3,16 2,97 SEER 6,5 7,0 6,4 6,2 Energy label cooling A++ A++ A++ A++ 5,57 (1,20~6,76) 7,33 (1,57~9,09) Heating capacity kW 2,88 (1,27~3,56) 3,75 (1,03~4,95) Power consumption W 627 (160~1.270) 991 (162~1.770) Operating current A 1.495 (231~2.490) 2.232 (284~3.240) 2,73 (0,7~5,53) 4,31 (0,7~7,69) 6,50 (1,0~10,81) 9,70 (1,23~14,11) COP 4,59 3,78 3,73 3,28 SCOP (Average) 4,0 4,1 4,0 4,0 Energy label heating A+ A+ A+ A+ Indoor Unit m3/h 650/530/400 700/580/500 1.250/980/820 1.450/1.300/1.200 Sound pressure level (H/M/L) dB(A) 43/38/28 43/37/31 48/41/35 49/46/42 Sound power level (H) dB(A) 56 57 60 63 Air flow rate (H/M/L) Dimensions LxWxH mm 835x198x280 835x198x280 990x218x315 1.186x258x340 Packing LxWxH mm 910x270x355 910x270x335 1.065x300x400 1.265x420x340 8/10 9/11,5 12/15 17/22 Net/gross weight kg Outdoor Unit Compressor Type Rotary Twin-rotary Sound pressure level (H) dB(A) 45 45 47 Sound power level (H) dB(A) 62 62 64 52 69 Dimensions LxWxH mm 780x250x540 810x310x558 810x310x558 845x320x700 Packing LxWxH mm 910x335x585 930x400x615 930x400x615 965x395x755 28/30 30,5/33 37/39 47/50,5 Net/gross weight Piping diameters kg Liquid mm (inch) 6,35 (1/4”) 6,35 (1/4”) 6,35 (1/4”) 9,52 (3/8”) Gas mm (inch) 15,9 (5/8”) 9,52 (3/8”) 9,52 (3/8”) 12,7 (1/2”) mm 16 16 16 16 Max. input current A 9,0 11,5 11,5 13,5 Maximum lenght of the line m 25 25 30 30 Maximum height difference m 10 10 20 20 Indoor temperature °C +17…+32 cooling / heating 0 … +30 Outdoor temperature °C -15 ... +50 cooling / heating -15 ... +30 Drainage Nominal conditions Indoor unit Outdoor unit Piping lenght Level difference Cooling mode 27°C DB, 19°C WB 35°C DB 5m 0m Heating mode 20°C DB, 19°C WB 7°C DB, 6°C WB 5m 0m Seasonal efficiency according to EN 14825. The sound pressure value may vary depending on ambient conditions. 17 18 | Hi-wall Inverter Split Hi-wall Inverter Split SYSPLIT WALL INV HP Features SYSPLIT WALL INV are the most affordable and reliable solution for small offices and residential premises. High efficient DC inverter control provides accurate regulation of the room temperature. Stylish appearance with big LCD showing all main settings of the air conditioner. Outdoor units are equipped with valve protection cover. Self-diagnosis function continuosly monitors the operation of the air conditioner and protect the system. Refrigerante leakage detection can prevent the compressor being damaged by refrigerant leakage or compressor overload. The cold catalyst filter effectively decomposes volatile compounds and it has anti-bacteria effect. It is washable and maintains the effect for long time. With Turbo mode the unit will run with the ultra-high speed for 20 minutes to reach more quickly the set-point temperature. Hydrophylic aluminium fins of the indoor units improve the heat exchange efficiency in cooling and heating mode. Infrared remote control SYSCONTROL RM 52 (standard) Power factor capacitors included in the outdoor unit allow an active PF around 97%. With the Auto-restart function the unit resumes with the same settings before the electric power failure. Environment friendly refrigerant R410A. Infrared remote control SYSCONTROL RM 52 included. Dimensions SYSPLIT WALL IN SYSPLIT WALL OUT D B A Air inlet B C C Air inlet A E Air outlet Model 09 12 18 24 Model 09 12 18 24 A 800 800 940 1.045 A 780 780 760 845 B 188 188 205 235 B 540 540 590 700 C 275 275 275 315 C 250 250 285 320 D 549 549 530 560 E 276 276 290 335 Hi-wall Inverter Split | Technical features Model Indoor unit SYSPLIT WALL IN 09 INV HP Q IN 12 INV HP Q IN 18 INV HP Q IN 24 INV HP Q Model Outdoor unit SYSPLIT WALL OUT 09 INV HP Q OUT 12 INV HP Q OUT 18 INV HP Q OUT 24 INV HP Q Art. no. Indoor unit 314163 314164 314165 314166 Art. no. Outdoor unit 314000 314001 314002 314003 R410A / 0,8 R410A / 0,8 R410A / 1,25 R410A / 1,95 kW 2,64 (1,30~3,22) 3,22 (1,41~4,29) Power consumption W 790 (144~1.240) Operating current A Refrigerant / Changed quantity Power supply kg V/Ph/Hz Cooling capacity 220-240/1/50 4,98 (1,91~5,90) 6,45 (2,18~7,09) 1.000 (139~1.650) 1.550 (157~2.270) 2.000 (204~2.730) 3,4 (0,63~5,39) 4,4 (0,60~7,17) 6,7 (0,68~9,87) 8,7 (0,89~11,87) EER 3,34 3,22 3,21 3,23 SEER 5,6 5,6 6,1 5,9 Energy label cooling A+ A+ A++ A+ kW 2,93 (1,01~3,45) 3,66 (0,98~4,54) 5,28 (1,27~6,23) 6,74 (1,60~8,65) Power consumption W 730 (175~1.230) Operating current A 3,2 (0,76~5,35) 4,4 (0,77~7,04) 6,2 (0,83~9,65) 7,9 (1,27~13,43) COP 4,01 3,63 3,71 3,72 SCOP (Average) 3,8 3,8 3,8 3,8 A A A A Heating capacity Energy label heating 1.010 (177~1.620) 1.420 (191~2.220) 1.810 (293~3.090) Indoor Unit m3/h 620/540/440 630/550/430 730/480/400 1.150/1.050/900 Sound pressure level (H/M/L) dB(A) 41/38/31 43/40/31 41/33/31 49/47/41 Sound power level (H) dB(A) 57 57 57 63 Air flow rate (H/M/L) Dimensions LxWxH mm 800x188x275 800x188x275 940x205x275 1.045x235x315 Packing LxWxH mm 865x265x350 865x265x350 1.015x265x350 1.135x395x350 7,5/9,5 7,5/9,5 9/12,5 12,5/15,5 Net/gross weight kg Outdoor Unit Compressor Type Rotary Twin-rotary Sound pressure level (H) dB(A) 46 46 48 Sound power level (H) dB(A) 63 63 65 51 68 Dimensions LxWxH mm 780x250x540 780x250x540 760x285x590 845x320x700 Packing LxWxH mm 910x335x585 910x335x585 887x355x645 965x395x755 28/30 28/30 34,5/37 47/50 Net/gross weight Piping diameters kg Liquid mm (inch) 6,35 (1/4”) 6,35 (1/4”) 6,35 (1/4”) 9,52 (3/8”) Gas mm (inch) 15,9 (5/8”) 9,52 (3/8”) 9,52 (3/8”) 12,7 (1/2”) mm 16 16 16 16 Max. input current A 9,0 11,5 12,5 13,5 Maximum lenght of the line m 20 20 20 25 Maximum height difference m 8 8 8 10 Drainage Indoor temperature °C +17…+32 cooling / heating 0 … +30 Outdoor temperature °C 0 ... +50 cooling / heating -15 ... +30 Nominal conditions Indoor unit Outdoor unit Piping lenght Level difference Cooling mode 27°C DB, 19°C WB 35°C DB 5m 0m Heating mode 20°C DB, 19°C WB 7°C DB, 6°C WB 5m 0m Seasonal efficiency according to EN 14825. The sound pressure value may vary depending on ambient conditions. 19 20 | Multi-split Inverter High efficiency Multi-split Inverter High efficiency SYSPLIT MULTI EVO HP Features SYSPLIT MULTI EVO are ideal and flexible solution for providing quiet and efficient air conditioning for 2 to 5 areas from a single outdoor unit. SYSPLIT MULTI outdoor units are compatible with SYSPLIT WALL EVO, CASSETTE EVO and DUCT EVO indoor units. DC inverter technology for precise temperature control and a low start-up current. Robust and reliable structure, cabinet made of zinc steel sheet. Outdoor units are equipped with valve protection cover. Twin-rotary compressors assure high efficient operation, minimal vibration and low noise level. All indoor units are equipped with DC Inverter fan motor. Hydrophylic aluminium fins improve the heat exchange efficiency reducing the defrosting cycle time. Cooling and heating operation down to -15°C outdoor temperature assures an operation all year round. Power factor capacitors included in the unit allow an active PF around 97%. With the Auto-restart function the unit resumes with the same settings before the electric power failure. Environment friendly refrigerant R410A. B Dimensions SYSPLIT MULTI A B E C D A Model A 14 18 21 28 36 42 845 845 900 990 990 B 700 845 C 700 700 860 965 965 C 320 320 320 315 345 345 D 560D 560 560 590 624 624 E 335 335 335 333 366 366 E Multi-split Inverter High efficiency | Technical features Model SYSPLIT MULTI2 14 EVO HP Q Art. no. Outdoor unit MULTI2 18 EVO HP Q MULTI3 21 EVO HP Q MULTI4 28 EVO HP Q MULTI5 36 EVO HP Q MULTI5 42 EVO HP Q 314011 314012 314013 314014 314015 314264 R410A / 1,55 R410A / 1,9 R410A / 2,1 R410A / 2,4 R410A / 3,0 R410A / 3,5 kW 4,11 5,26 6,16 8,20 10,56 12,30 Power consumption W 1.260 1.600 1.900 2.470 3.280 3.730 Operating current A Refrigerant / Charged quantity Power supply kg V/Ph/Hz Cooling capacity EER 220-240/1/50 5,7 7,0 8,3 11,2 14,6 17,1 3,26 3,29 3,24 3,32 3,22 3,30 SEER 6,1 6,3 6,4 6,4 5,7 - Energy label cooling A++ A++ A++ A++ A+ - kW 4,68 6,15 6,74 9,08 12,31 12,30 Power consumption Heating capacity W 1.450 1.700 1.750 2.440 3.400 3.370 Operating current A 6,5 7,4 7,6 11,1 15,3 15,4 COP 3,23 3,62 3,85 3,72 3,62 3,65 SCOP (Average) 4,0 4,2 4,1 3,8 3,8 - Energy label heating A+ A+ A+ A A Twin-rotary Outdoor Unit Type Rotary Twin-rotary Twin-rotary Twin-rotary Twin-rotary Sound pressure level (H) Compressor dB(A) 45 46 47 53 51 55 Sound power level (H) dB(A) 62 63 64 70 68 72 900x315x860 990x345x965 990x345x965 Dimensions LxWxH mm 845x320x700 845x320x700 845x320x700 Packing LxWxH mm 965x395x755 965x375x755 965x395x755 1.043x395x915 1.120x435x1.100 1.120x435x1.100 Net/gross weight Piping diameters 44/47 48/52 50/54 65/69 80/91 89/93 Liquid inch kg 2x 6,35 (1/4”) 2x 6,35 (1/4”) 3x 6,35 (1/4”) 4x 6,35 (1/4”) 5x 6,35 (1/4”) 5x 6,35 (1/4”) Gas inch 2x 9,52 (3/8”) 2x 9,52 (3/8”) 3x 9,52 (3/8”) 4x 9,52 (3/8”) 5x 9,52 (3/8”) 5x 9,52 (3/8”) Max. input current A 11,0 14,5 15,0 17,0 22,0 28,0 Maximum lenght all lines m 30 30 45 60 75 75 Maximum lenght of the line m 20 20 25 30 30 30 Maximum height difference OU higher than IU/ OU lower than IU m 10/15 10/15 10/15 10/15 10/15 10/15 Outdoor temperature °C -15 ... +50 cooling / heating -15 ... +24 Rated performance at 100% of combination. For combination exceeding 100% the cooling and heating capacities of the indoor units will be proportionally reduced. Nominal conditions Indoor unit Outdoor unit Piping lenght Level difference Cooling mode 27°C DB, 19°C WB 35°C DB 5m 0m Heating mode 20°C DB, 19°C WB 7°C DB, 6°C WB 5m 0m Seasonal efficiency according to EN 14825. The sound pressure value may vary depending on ambient conditions. 21 22 | Multi-split indoor units Indoor units for SYSPLIT MULTI EVO Infrared remote control SYSCONTROL RM 52 (standard) Wall mounted indoor unit SYSPLIT WALL IN EVO HP Q Model indoor unit SYSPLIT WALL Art. no. Indoor unit IN 07 EVO HP Q IN 09 EVO HP Q IN 12 EVO HP Q IN 18 EVO HP Q IN 24 EVO HP Q 314017 314018 314019 314167 Cooling capacity kW 2,02 2,60 3,47 4,91 6,02 Heating capacity kW 2,31 2,89 3,76 5,20 6,84 Power consumption W 24 24 24 62 91 Operating current A 0,11 0,11 0,11 0,28 0,40 m3/h 650/530/400 650/530/400 dB(A) 43/38/28 43/38/28 Air flow rate (H/M/L) Sound pressure level (H/M/L) Piping diameters 314016 700/580/500 1.250/980/820 1.450/1.300/1.200 43/37/31 48/41/35 49/46/42 Liquid inch 6,35 (1/4”) 6,35 (1/4”) 6,35 (1/4”) 6,35 (1/4”) 9,52 (3/8”) Gas inch 9,52 (3/8”) 9,52 (3/8”) 9,52 (3/8”) 12,7 (1/2”) 15,9 (5/8”) Drainage mm 16 16 16 16 16 mm 835x198x280 835x198x280 835x198x280 990x218x315 1.186x258x340 8 8 9 12 17 Dimensions LxWxH Unit weight kg Infrared remote control SYSCONTROL RM 52 (standard) Cassette indoor unit SYSPLIT CASSETTE EVO HP Q Model indoor unit SYSPLIT CASSETTE 07 EVO HP Q 09 EVO HP Q 12 EVO HP Q M 18 EVO HP Q MINI SPLIT MINI SPLIT MINI SPLIT MINI SPLIT Art. no. Indoor unit 314020 314021 314028 314171 Art. no. Panel unit 314032 314032 314032 314032 Model panel unit SYSPANEL CASSETTE Cooling capacity kW 2,02 2,60 3,47 5,20 Heating capacity kW 2,31 2,89 3,76 5,20 Power consumption W 40 40 102 102 Operating current A 0,18 0,18 0,44 0,44 m3/h 580 580 800 800 dB(A) 32 32 37 42 Air flow rate (H/M/L) Sound pressure level (H) Piping diameters Liquid inch 6,35 (1/4”) 6,35 (1/4”) 6,35 (1/4”) 6,35 (1/4”) Gas inch 9,52 (3/8”) 9,52 (3/8”) 9,52 (3/8”) 12,7 (1/2”) Drainage mm 25 25 25 25 Dimensions LxWxH mm Unit weight kg 570(647)x570(647)x260(50) 16(2,5) 16(2,5) 16(2,5) Wired controller SYSCONTROL WC 90 (standard) Duct indoor unit SYSPLIT DUCT EVO HP Q Model indoor unit 18(2,5) SYSPLIT DUCT Art. no. Indoor unit 07 EVO HP Q 09 EVO HP Q 12 EVO HP Q M 18 EVO HP Q 314024 314025 314026 314172 Cooling capacity kW 2,02 2,60 3,47 5,20 Heating capacity kW 2,31 2,89 3,76 5,78 Power consumption W 30 30 40 107 Operating current A 0,13 0,13 0,17 0,48 m3/h 600 600 680 1.000 Pa 40 40 40 70 dB(A) 38 38 40 42 Air flow rate (H/M/L) External static pressure (H) Sound pressure level (H) Piping diameters Dimensions LxWxH Unit weight Liquid inch 6,35 (1/4”) 6,35 (1/4”) 6,35 (1/4”) 6,35 (1/4”) Gas inch 9,52 (3/8”) 9,52 (3/8”) 9,52 (3/8”) 12,7 (1/2”) Drainage mm 25 25 25 25 mm 700x635x210 700x635x210 700x635x210 920x635x210 19,5 19,5 18 23 kg Multi-split combination | Combination table SYSPLIT MULTI EVO SYSPLIT MULTI2 14 EVO HP Q One Unit Two Unit 7 7+7 9 7+9 12 7+12 18 9+9 9+12 SYSPLIT MULTI2 18 EVO HP Q One Unit Two Unit 7 7+7 9 7+9 12 7+12 18 7+18 9+9 9+12 9+18 12+12 SYSPLIT MULTI3 21 EVO HP Q One Unit Two Unit Three Unit 7 7+7 7+7+7 9 7+9 7+7+9 12 7+12 7+7+12 18 7+18 7+9+9 9+9 7+9+12 9+12 9+9+9 9+18 9+9+12 12+12 SYSPLIT MULTI4 28 EVO HP Q One Unit Two Unit Three Unit Four Unit 7 7+7 7+7+7 7+7+7+7 9 7+9 7+7+9 7+7+7+9 12 7+12 7+7+12 7+7+7+12 18 7+18 7+9+9 7+7+7+18 9+9 7+9+12 7+7+9+9 9+12 7+9+18 7+7+9+12 7+7+12+12 9+18 7+7+18 12+12 9+9+9 7+9+9+9 12+18 9+9+12 7+9+9+12 18+18 7+12+18 9+9+9+9 9+9+18 7+9+12+12 12+12+12 9+9+9+12 9+12+12 7+12+12 * In case combination of indoor units exceeds the nominal capacity of outdoor unit the capacity of each indoor units is smaller. 23 24 | Multi-split combination Combination table SYSPLIT MULTI EVO SYSPLIT MULTI5 36 EVO HP Q One Unit Two Unit Three Unit Four Unit Five Unit 7 7+7 7+7+7 7+7+7+7 7+7+7+7+7 9 7+9 7+7+9 7+7+7+9 7+7+7+7+9 12 7+12 7+7+12 7+7+7+12 7+7+7+7+12 18 7+18 7+7+18 7+7+7+18 7+7+7+7+18 9+9 7+9+9 7+7+9+9 7+7+7+9+9 9+12 7+9+12 7+7+9+12 7+7+7+9+12 7+7+7+12+12 9+18 7+9+18 7+7+9+18 12+12 7+12+12 7+7+12+12 7+7+9+9+9 12+18 7+12+18 7+7+12+18 7+7+9+9+12 18+18 7+18+18 7+9+9+9 7+9+9+9+9 9+9+9 7+9+9+12 7+9+9+9+12 9+9+12 7+9+9+18 9+9+9+9+9 9+9+18 7+9+12+12 9+9+9+9+12 9+12+12 7+9+12+18 9+9+9+9+18 9+12+18 7+12+12+12 9+9+9+12+12 12+12+12 9+9+9+9 9+9+9+12+18 12+12+18 9+9+9+12 9+9+12+12+12 12+18+18 9+9+9+18 9+12+12+12+12 18+18+18 9+9+12+12 12+12+12+12+12 9+12+12+12 9+12+12+18 12+12+12+12 12+12+12+18 SYSPLIT MULTI5 42 EVO HP Q One Unit Two Unit 7 7+7 7+7+7 Three Unit 9+9+18 7+7+7+7 Four Unit 7+9+12+24 7+7+7+7+7 Five Unit 7+7+9+18+18 9 7+9 7+7+9 9+9+24 7+7+7+9 7+9+18+18 7+7+7+7+9 7+7+12+12+12 7+7+12+12+18 12 7+12 7+7+12 9+12+12 7+7+7+12 7+9+18+24 7+7+7+7+12 18 7+18 7+7+18 7+12+12 7+7+7+18 7+12+12+12 7+7+7+7+18 7+9+9+9+9 24 7+24 7+7+24 9+12+18 7+7+7+24 7+12+12+18 7+7+7+7+24 7+9+9+9+12 9+9 7+9+9 9+12+24 7+7+9+9 7+12+12+24 7+7+7+9+9 7+9+9+9+18 9+12 7+9+12 9+18+18 7+7+9+12 7+12+18+18 7+7+7+9+12 7+9+9+9+24 9+18 7+9+18 12+12+12 7+7+9+18 9+9+9+9 7+7+7+9+18 7+9+9+12+12 9+24 7+9+24 12+12+18 7+7+9+24 9+9+9+12 7+7+7+9+24 7+9+9+12+18 12+12 7+12+12 12+12+24 7+7+12+12 9+9+9+18 7+7+7+12+12 7+9+12+12+12 12+18 7+12+18 12+18+18 7+7+12+18 9+9+9+24 7+7+7+12+18 7+9+12+12+18 7+12+12+12+12 12+24 7+12+24 12+18+24 7+7+12+24 9+9+12+12 7+7+7+12+24 18+18 7+18+18 18+18+18 7+7+18+18 9+9+12+18 7+7+7+18+18 9+9+9+9+9 18+24 9+9+9 18+18+18 7+7+18+24 9+9+12+24 7+7+9+9+9 9+9+9+9+12 24+24 9+9+12 7+9+9+9 9+9+18+18 7+7+9+9+12 9+9+9+9+18 7+9+9+12 9+12+12+12 7+7+9+9+18 9+9+9+12+12 7+9+9+18 9+12+12+18 7+7+9+9+24 9+9+9+12+18 7+9+9+24 9+12+12+24 7+7+9+12+12 9+9+12+12+12 7+9+12+12 9+12+18+18 7+7+9+12+18 9+12+12+12+12 7+9+12+18 12+12+12+12 12+12+12+18 * In case combination of indoor units exceeds the nominal capacity of outdoor unit the capacity of each indoor units is smaller. Multi-split combination | Rated capacity table SYSPLIT MULTI EVO SYSPLIT MULTI2 14 EVO HP Q COOLING Comb. 1:2 Combinations Rated Capacity (kW) Total Cooling Capacity (kW) Unit A Unit B Unit A Unit B min. data rated data max. data 7 7 2,05 2,05 2,87 4,10 5,13 7 9 2,00 2,50 3,15 4,50 5,31 7 12 1,95 3,00 3,47 4,95 5,35 9 9 2,45 2,45 3,43 4,90 5,35 9 12 2,40 2,95 3,75 5,35 5,35 HEATING Comb. 1:2 Combinations Rated Capacity (kW) Total Cooling Capacity (kW) Unit A Unit B Unit A Unit B min. data rated data max. data 7 7 2,35 2,35 3,29 4,70 5,41 7 9 2,25 2,75 3,50 5,00 5,50 7 12 2,15 3,25 3,78 5,40 5,70 9 9 2,60 2,60 3,64 5,20 5,70 9 12 2,50 3,20 3,99 5,70 5,70 SYSPLIT MULTI2 18 EVO HP Q COOLING Comb. 1:2 Combinations Rated Capacity (kW) Total Cooling Capacity (kW) Unit A Unit B Unit A Unit B min. data rated data max. data 7 7 2,10 2,10 2,94 4,20 5,46 7 9 2,10 2,50 3,22 4,60 5,98 7 12 2,10 3,50 3,92 5,60 6,70 7 18 1,90 4,75 4,66 6,65 6,70 9 9 2,64 2,64 3,70 5,28 6,70 9 12 2,50 3,50 4,20 6,00 6,70 9 18 2,10 4,60 4,69 6,70 6,70 12 12 3,30 3,30 4,62 6,60 6,70 HEATING Comb. 1:2 Combinations Rated Capacity (kW) Total Heating Capacity (kW) Unit A Unit B Unit A Unit B min. data rated data max. data 7 7 2,40 2,40 3,36 4,80 6,24 7 9 2,35 2,95 3,71 5,30 6,89 7 12 2,25 3,70 4,17 5,95 7,20 7 18 2,10 5,05 5,01 7,15 7,20 9 9 3,08 3,08 4,31 6,16 7,20 9 12 2,80 3,60 4,48 6,40 7,20 9 18 2,45 4,75 5,04 7,20 7,20 12 12 3,45 3,45 4,83 6,90 7,20 25 26 | Multi-split combination Rated capacity table SYSPLIT MULTI EVO SYSPLIT MULTI3 21 EVO HP Q COOLING Comb. 1:3 Combinations Rated Capacity (kW) Total Cooling Capacity (kW) Unit A Unit B Unit C Unit A Unit B Unit C min. data rated data 7 7 7 2,05 2,05 2,05 4,00 6,15 max. data 7,07 7 7 9 1,95 1,95 2,54 4,19 6,45 7,22 7 7 12 1,93 1,93 3,09 4,52 6,95 7,51 7 9 9 1,89 2,46 2,46 4,42 6,80 7,48 7 9 12 1,86 2,42 2,97 4,71 7,25 7,60 9 9 9 2,37 2,37 2,37 4,62 7,10 7,60 9 9 12 2,35 2,35 2,90 4,94 7,60 7,60 HEATING Comb. 1:3 Combinations Rated Capacity (kW) Total Cooling Capacity (kW) Unit A Unit B Unit C Unit A Unit B Unit C min. data rated data 7 7 7 2,25 2,25 2,25 4,38 6,74 max. data 7,55 7 7 9 2,12 2,12 2,76 4,55 7,00 7,70 7 7 12 2,05 2,05 3,28 4,80 7,38 7,86 7 9 9 2,01 2,62 2,62 4,71 7,25 7,83 7 9 12 1,96 2,55 3,13 4,97 7,64 7,90 9 9 9 2,51 2,51 2,51 4,89 7,52 7,90 9 9 12 2,45 2,45 3,01 5,14 7,90 7,90 Multi-split combination | SYSPLIT MULTI4 28 EVO HP Q COOLING Comb. 1:4 Combinations Rated Capacity (kW) Total Cooling Capacity (kW) Unit A Unit B Unit C Unit D Unit A Unit B Unit C Unit D min. data rated data max. data 7 7 7 7 2,05 2,05 2,05 2,05 5,34 8,21 9,20 7 7 7 9 1,98 1,98 1,98 2,57 5,53 8,50 9,35 7 7 7 12 1,94 1,94 1,94 3,10 5,80 8,92 9,72 7 7 7 18 1,73 1,73 1,73 4,60 6,37 9,80 9,94 7 7 9 9 1,91 1,91 2,49 2,49 5,72 8,80 9,68 7 7 9 12 1,88 1,88 2,45 3,01 5,99 9,22 9,87 7 7 12 12 1,86 1,86 2,97 2,97 6,27 9,65 9,94 7 9 9 9 1,85 2,41 2,41 2,41 5,90 9,08 9,81 7 9 9 12 1,83 2,38 2,38 2,93 6,18 9,51 9,94 7 9 12 12 1,81 2,35 2,89 2,89 6,46 9,94 9,94 9 9 9 9 2,34 2,34 2,34 2,34 6,07 9,34 9,94 9 9 9 12 2,32 2,32 2,32 2,85 6,37 9,80 9,94 HEATING Comb. 1:4 Combinations Rated Capacity (kW) Total Cooling Capacity (kW) Unit A Unit B Unit C Unit D Unit A Unit B Unit C Unit D min. data rated data max. data 7 7 7 7 2,27 2,27 2,27 2,27 6,36 9,09 10,00 7 7 7 9 2,17 2,17 2,17 2,82 6,54 9,34 10,18 7 7 7 12 2,11 2,11 2,11 3,38 6,80 9,72 10,50 7 7 7 18 1,85 1,85 1,85 4,91 7,33 10,47 10,60 7 7 9 9 2,09 2,09 2,71 2,71 6,72 9,60 10,46 7 7 9 12 2,04 2,04 2,65 3,26 6,99 9,98 10,58 7 7 12 12 1,99 1,99 3,18 3,18 7,25 10,35 10,60 7 9 9 9 2,01 2,61 2,61 2,61 6,90 9,85 10,54 7 9 9 12 1,96 2,55 2,55 3,14 7,14 10,20 10,60 7 9 12 12 1,93 2,51 3,08 3,08 7,42 10,60 10,60 9 9 9 9 2,53 2,53 2,53 2,53 7,07 10,10 10,60 9 9 9 12 2,47 2,47 2,47 3,05 7,33 10,47 10,60 27 28 | Multi-split combination Rated capacity table SYSPLIT MULTI EVO SYSPLIT MULTI5 36 EVO HP Q COOLING Comb. 1:5 Combinations Rated Capacity (kW) Total Cooling Capacity (kW) Unit A Unit B Unit C Unit D Unit E Unit A Unit B Unit C Unit D Unit E 7 7 7 7 7 2,11 2,11 2,11 2,11 2,11 min. data 6,86 10,55 max. data 12,45 7 7 7 7 9 2,05 2,05 2,05 2,05 2,66 7,05 10,85 12,80 7 7 7 7 12 2,02 2,02 2,02 2,02 3,23 7,35 11,31 13,23 7 7 7 7 18 1,84 1,84 1,84 1,84 4,87 7,95 12,23 13,94 7 7 7 9 9 1,99 1,99 1,99 2,59 2,59 7,25 11,16 13,06 7 7 7 9 12 1,97 1,97 1,97 2,56 3,15 7,55 11,62 13,36 7 7 7 9 18 1,80 1,80 1,80 2,34 4,78 8,14 12,53 14,03 7 7 7 12 12 1,95 1,95 1,95 3,12 3,12 7,85 12,08 13,53 7 7 7 12 18 1,79 1,79 1,79 2,87 4,75 8,44 12,99 14,36 7 7 7 18 18 1,67 1,67 1,67 4,44 4,44 9,04 13,90 14,36 7 7 9 9 9 1,94 1,94 2,53 2,53 2,53 7,45 11,46 13,29 7 7 9 9 12 1,92 1,92 2,50 2,50 3,08 7,75 11,92 13,71 7 7 9 12 12 1,90 1,90 2,48 3,05 3,05 8,05 12,38 13,87 7 7 9 12 18 1,76 1,76 2,29 2,82 4,66 8,64 13,29 14,36 7 7 12 12 12 1,89 1,89 3,02 3,02 3,02 8,35 12,84 14,25 7 7 12 12 18 1,75 1,75 2,80 2,80 4,64 8,94 13,75 14,36 7 9 9 9 9 1,90 2,47 2,47 2,47 2,47 7,65 11,77 13,42 7 9 9 9 12 1,88 2,45 2,45 2,45 3,01 7,95 12,23 13,94 7 9 9 9 18 1,74 2,26 2,26 2,26 4,61 8,54 13,14 14,36 7 9 9 12 12 1,86 2,42 2,42 2,98 2,98 8,24 12,68 14,20 7 9 9 12 18 1,73 2,25 2,25 2,77 4,59 8,84 13,60 14,36 7 9 12 12 12 1,85 2,41 2,96 2,96 2,96 8,54 13,14 14,36 7 9 12 12 18 1,72 2,24 2,76 2,76 4,57 9,13 14,05 14,36 9 9 9 9 9 2,42 2,42 2,42 2,42 2,42 7,85 12,08 13,77 9 9 9 9 12 2,40 2,40 2,40 2,40 2,95 8,14 12,53 14,03 9 9 9 9 18 2,23 2,23 2,23 2,23 4,54 8,74 13,45 14,36 9 9 9 12 12 2,38 2,38 2,38 2,93 2,93 8,44 12,99 14,36 9 9 9 12 18 2,22 2,22 2,22 2,73 4,52 9,04 13,90 14,36 9 9 12 12 12 2,36 2,36 2,91 2,91 2,91 8,74 13,45 14,36 9 12 12 12 12 2,35 2,89 2,89 2,89 2,89 9,04 13,90 14,36 12 12 12 12 12 2,87 2,87 2,87 2,87 2,87 9,33 14,36 14,36 rated data Multi-split combination | HEATING Comb. 1:5 Combinations Rated Capacity (kW) Total Cooling Capacity (kW) Unit A Unit B Unit C Unit D Unit E Unit A Unit B Unit C Unit D Unit E 7 7 7 7 7 2,46 2,46 2,46 2,46 2,46 min. data 8,00 12,31 max. data 14,16 7 7 7 7 9 2,37 2,37 2,37 2,37 3,08 8,16 12,56 14,19 7 7 7 7 12 2,31 2,31 2,31 2,31 3,69 8,40 12,93 14,35 7 7 7 7 18 2,06 2,06 2,06 2,06 5,45 8,89 13,67 14,76 7 7 7 9 9 2,29 2,29 2,29 2,97 2,97 8,32 12,80 14,27 7 7 7 9 12 2,23 2,23 2,23 2,90 3,57 8,57 13,18 14,43 7 7 7 9 18 2,00 2,00 2,00 2,60 5,31 9,05 13,92 15,03 7 7 7 12 12 2,19 2,19 2,19 3,50 3,50 8,81 13,55 14,63 7 7 7 12 18 1,97 1,97 1,97 3,15 5,22 9,29 14,29 15,40 7 7 7 18 18 1,81 1,81 1,81 4,80 4,80 9,77 15,03 15,40 7 7 9 9 9 2,21 2,21 2,88 2,88 2,88 8,48 13,05 14,36 7 7 9 9 12 2,16 2,16 2,81 2,81 3,46 8,72 13,42 14,56 7 7 9 12 12 2,12 2,12 2,76 3,40 3,40 8,97 13,80 14,90 7 7 9 12 18 1,92 1,92 2,50 3,08 5,10 9,44 14,53 15,40 7 7 12 12 12 2,08 2,08 3,33 3,33 3,33 9,20 14,16 15,29 7 7 12 12 18 1,90 1,90 3,04 3,04 5,03 9,69 14,90 15,40 7 9 9 9 9 2,15 2,79 2,79 2,79 2,79 8,65 13,30 14,50 7 9 9 9 12 2,10 2,73 2,73 2,73 3,36 8,89 13,67 14,76 7 9 9 9 18 1,91 2,48 2,48 2,48 5,06 9,37 14,41 15,40 7 9 9 12 12 2,06 2,68 2,68 3,30 3,30 9,13 14,04 15,16 7 9 9 12 18 1,88 2,45 2,45 3,01 4,99 9,61 14,78 15,40 7 9 12 12 12 2,03 2,64 3,25 3,25 3,25 9,37 14,41 15,40 7 9 12 12 18 1,86 2,42 2,97 2,97 4,93 9,85 15,15 15,40 9 9 9 9 9 2,71 2,71 2,71 2,71 2,71 8,81 13,55 14,63 9 9 9 9 12 2,66 2,66 2,66 2,66 3,28 9,05 13,92 15,03 9 9 9 9 18 2,43 2,43 2,43 2,43 4,95 9,53 14,66 15,40 9 9 9 12 12 2,62 2,62 2,62 3,22 3,22 9,29 14,29 15,40 9 9 9 12 18 2,40 2,40 2,40 2,95 4,89 9,77 15,03 15,40 9 9 12 12 12 2,58 2,58 3,17 3,17 3,17 9,53 14,66 15,40 9 12 12 12 12 2,54 3,12 3,12 3,12 3,12 9,77 15,03 15,40 12 12 12 12 12 3,08 3,08 3,08 3,08 3,08 10,01 15,40 15,40 rated data 29 30 | Multi-split combination Rated capacity table SYSPLIT MULTI EVO SYSPLIT MULTI5 42 EVO HP Q COOLING Comb. 1:5 Combinations Rated Capacity (kW) Total Cooling Capacity (kW) Unit A Unit B Unit C Unit D Unit E Unit A Unit B Unit C Unit D Unit E 7 7 7 7 7 2,11 2,11 2,11 2,11 2,11 min. data 4,43 10,55 max. data 11,61 7 7 7 7 9 2,07 2,07 2,07 2,07 2,69 4,61 10,97 14,26 7 7 7 7 12 2,02 2,02 2,02 2,02 3,23 4,75 11,31 14,29 7 7 7 7 18 1,88 1,88 1,88 1,88 4,97 5,24 12,48 14,42 7 7 7 7 24 1,79 1,79 1,79 1,79 6,26 5,64 13,42 14,52 7 7 7 9 9 2,02 2,02 2,02 2,62 2,62 4,75 11,31 14,29 7 7 7 9 12 1,97 1,97 1,97 2,56 3,15 4,87 11,61 13,28 7 7 7 9 18 1,84 1,84 1,84 2,40 4,88 5,38 12,81 14,45 7 7 7 9 24 1,76 1,76 1,76 2,29 6,17 5,78 13,76 14,55 7 7 7 12 12 1,93 1,93 1,93 3,09 3,09 5,02 11,96 13,84 7 7 7 12 18 1,81 1,81 1,81 2,90 4,80 5,52 13,15 14,49 7 7 7 12 24 1,74 1,74 1,74 2,78 6,09 5,92 14,09 14,59 7 7 7 18 18 1,72 1,72 1,72 4,57 4,57 6,01 14,32 14,61 7 7 9 9 9 1,97 1,97 2,57 2,57 2,57 4,89 11,64 14,33 7 7 9 9 12 1,93 1,93 2,51 2,51 3,09 5,03 11,98 14,36 7 7 9 9 18 1,81 1,81 2,36 2,36 4,80 5,52 13,15 14,49 7 7 9 9 24 1,74 1,74 2,26 2,26 6,09 5,92 14,09 14,59 7 7 9 12 12 1,89 1,89 2,46 3,03 3,03 5,17 12,31 14,40 7 7 9 12 18 1,79 1,79 2,32 2,86 4,73 5,66 13,48 14,53 7 7 9 18 18 1,70 1,70 2,21 4,51 4,51 6,15 14,65 14,65 7 7 12 12 12 1,86 1,86 2,98 2,98 2,98 5,31 12,64 14,44 7 7 12 12 18 1,76 1,76 2,82 2,82 4,66 5,80 13,81 14,56 7 9 9 9 9 1,93 2,51 2,51 2,51 2,51 5,03 11,98 14,36 7 9 9 9 12 1,89 2,46 2,46 2,46 3,03 5,17 12,31 14,40 7 9 9 9 18 1,79 2,32 2,32 2,32 4,73 5,66 13,48 14,53 7 9 9 9 24 1,72 2,23 2,23 2,23 6,01 6,06 14,43 14,63 7 9 9 12 12 1,86 2,42 2,42 2,98 2,98 5,31 12,64 14,44 7 9 9 12 18 1,76 2,29 2,29 2,82 4,66 5,80 13,81 14,56 7 9 12 12 12 1,83 2,38 2,92 2,92 2,92 5,45 12,98 14,47 7 9 12 12 18 1,74 2,26 2,78 2,78 4,60 5,94 14,15 14,60 7 12 12 12 12 1,80 2,88 2,88 2,88 2,88 5,59 13,31 14,51 9 9 9 9 9 2,46 2,46 2,46 2,46 2,46 5,17 12,31 14,40 9 9 9 9 12 2,42 2,42 2,42 2,42 2,98 5,31 12,64 14,44 9 9 9 9 18 2,29 2,29 2,29 2,29 4,66 5,80 13,81 14,56 9 9 9 12 12 2,38 2,38 2,38 2,92 2,92 5,45 12,98 14,47 9 9 9 12 18 2,26 2,26 2,26 2,78 4,60 5,94 14,15 14,60 9 9 12 12 12 2,34 2,34 2,88 2,88 2,88 5,59 13,31 14,51 9 12 12 12 12 2,30 2,84 2,84 2,84 2,84 5,73 13,65 14,54 rated data Multi-split combination | HEATING Comb. 1:5 Combinations Rated Capacity (kW) Total Cooling Capacity (kW) Unit A Unit B Unit C Unit D Unit E Unit A Unit B Unit C Unit D Unit E 7 7 7 7 7 2,17 2,17 2,17 2,17 2,17 min. data 4,55 10,84 max. data 11,87 7 7 7 7 9 2,10 2,10 2,10 2,10 2,73 4,68 11,14 12,58 7 7 7 7 12 2,04 2,04 2,04 2,04 3,27 4,80 11,43 13,28 7 7 7 7 18 1,89 1,89 1,89 1,89 5,00 5,27 12,54 15,41 7 7 7 7 24 1,85 1,85 1,85 1,85 6,46 5,81 13,84 15,46 7 7 7 9 9 2,04 2,04 2,04 2,65 2,65 4,80 11,43 13,28 7 7 7 9 12 1,99 1,99 1,99 2,58 3,18 4,92 11,72 13,99 7 7 7 9 18 1,87 1,87 1,87 2,43 4,96 5,46 13,00 15,43 7 7 7 9 24 1,83 1,83 1,83 2,38 6,42 6,01 14,30 15,48 7 7 7 12 12 1,94 1,94 1,94 3,10 3,10 5,05 12,02 14,69 7 7 7 12 18 1,86 1,86 1,86 2,97 4,92 5,65 13,46 15,45 7 7 7 12 24 1,82 1,82 1,82 2,92 6,38 6,20 14,76 15,50 7 7 7 18 18 1,82 1,82 1,82 4,81 4,81 6,33 15,07 15,51 7 7 9 9 9 1,99 1,99 2,58 2,58 2,58 4,92 11,72 13,99 7 7 9 9 12 1,94 1,94 2,52 2,52 3,10 5,05 12,02 14,69 7 7 9 9 18 1,86 1,86 2,41 2,41 4,92 5,65 13,46 15,45 7 7 9 9 24 1,82 1,82 2,37 2,37 6,38 6,20 14,76 15,50 7 7 9 12 12 1,89 1,89 2,46 3,03 3,03 5,17 12,31 15,40 7 7 9 12 18 1,84 1,84 2,40 2,95 4,89 5,85 13,92 15,47 7 7 9 18 18 1,81 1,81 2,35 4,79 4,79 6,52 15,53 15,53 7 7 12 12 12 1,88 1,88 3,00 3,00 3,00 5,36 12,77 15,42 7 7 12 12 18 1,83 1,83 2,93 2,93 4,85 6,04 14,38 15,48 7 9 9 9 9 1,94 2,52 2,52 2,52 2,52 5,05 12,02 14,69 7 9 9 9 12 1,89 2,46 2,46 2,46 3,03 5,17 12,31 15,40 7 9 9 9 18 1,84 2,40 2,40 2,40 4,89 5,85 13,92 15,47 7 9 9 9 24 1,81 2,36 2,36 2,36 6,34 6,39 15,22 15,52 7 9 9 12 12 1,88 2,44 2,44 3,00 3,00 5,36 12,77 15,42 7 9 9 12 18 1,83 2,38 2,38 2,93 4,85 6,04 14,38 15,48 7 9 12 12 12 1,86 2,42 2,98 2,98 2,98 5,56 13,23 15,44 7 9 12 12 18 1,82 2,37 2,91 2,91 4,83 6,23 14,84 15,50 7 12 12 12 12 1,85 2,96 2,96 2,96 2,96 5,75 13,69 15,46 9 9 9 9 9 2,46 2,46 2,46 2,46 2,46 5,17 12,31 15,40 9 9 9 9 12 2,44 2,44 2,44 2,44 3,00 5,36 12,77 15,42 9 9 9 9 18 2,38 2,38 2,38 2,38 4,85 6,04 14,38 15,48 9 9 9 12 12 2,42 2,42 2,42 2,98 2,98 5,56 13,23 15,44 9 9 9 12 18 2,37 2,37 2,37 2,91 4,83 6,23 14,84 15,50 9 9 12 12 12 2,41 2,41 2,96 2,96 2,96 5,75 13,69 15,46 9 12 12 12 12 2,39 2,94 2,94 2,94 2,94 5,94 14,15 15,47 rated data 31 | Cassette Inverter High efficiency Split Cassette Inverter High efficiency Split SYSPLIT CASSETTE EVO HP Features SYSPLIT CASSETTE EVO air conditioners are ideal solution for creating a comfortable climate in the office and shopping centers – in all rooms designed with false ceilings. Dimensions SYSPLIT CASSETTE size 12-18 840 (Body) Infrared remote controller SYSCONTROL RM 52 included; Wired remote SYSCONTROL WC 90 available as accessory. A A SYSPLIT OUTDOOR size 12 to 24 24 to 60 size 36 to 60 A H H E E C C D D 647(Panel) F F 570(Body) A Model A Hook 50 Ceiling 600 Outlet Inlet Outlet B Panel B 12 18 24 36 48 60 760 845 900 938 938 938 530 560 634 634 634 335 333 404 404 404 590 C 290 E C D Nut B A D 315 360 355 448 448 448 368 F H A Body H A A BB BB 780 (Hook-location) 840 (Body) 950 (Panel) 545(Hook-location) H 840 (Body) 950 (Panel) 680 (Hook-location) 570(Body) 647(Panel) 523(Hook-location) H H 780 (Hook-location) 840 (Body) size 950 (Panel) Wired controller SYSCONTROL WC 90 Art. no. 314139 (optional) Infrared remote control SYSCONTROL RM 52 (standard) 950 (Panel) 680 (Hook-location) Advanced DC inverter control for the compressor, outdoor fan motor and indoor fan motor. Available with 2 different sizes: 57x57 for models 12 and 18, 84x84 for models 24 to 60. The 360° round flow panel assures an optimal air distribution and comfort in the room. Special aerodynamic shape of the fan and the geometry of the blades ensure low noise from the air conditioner. Washable air filter included in the panel greatly simplifies the maintenance. The panel is equipped with an interactive LCD. Built-in drain pump with lift height up to 500 mm for models 12-18, and up to 750 mm for models 24 to 60. Fresh air intake can fufill air quality requirements and enhance occupants comfort. Auto-restart after electric power failure. Environment friendly refrigerant R410A. 260mm >2500 Model 12 18 24 36 48 60 E 270 312 302 368 368 A 260 260 245 245 287 287 F 285 320 315 392 392 392 H >280 >280 >260 >260 >330 >330 H 590 700 860 1.369 1.369 1.369 >2500 mm A H 32 Outlet Inlet Outlet Cassette Inverter High efficiency Split | Technical features Model Indoor unit SYSPLIT CASSETTE 12 EVO HP Q 18 EVO HP Q 24 EVO HP Q 36 EVO HP Q 36 EVO HP Q 48 EVO HP Q 60 EVO HP Q Model Outdoor unit SYSPLIT OUTDOOR 12 EVO HP Q 18 EVO HP Q 24 EVO HP Q 36 EVO HP Q 36 EVO HP R 48 EVO HP R 60 EVO HP R CASSETTE MINI SPLIT CASSETTE MINI SPLIT CASSETTE EVO SPLIT CASSETTE EVO SPLIT CASSETTE EVO SPLIT CASSETTE EVO SPLIT CASSETTE EVO SPLIT Model Panel unit SYSPANEL Art. no. Indoor unit 314028 314029 314030 314031 314031 314033 314035 Art. no. Outdoor unit 314056 314057 314058 314059 314060 314062 314063 314034 314034 314034 Art. no. Panel 314032 314032 314034 R410A / 1,1 R410A / 1,8 R410A / 2,2 kW 3,52 (1,11-4,53) 5,28 (1,29-7,37) 7,04 (1,46-8,77) 10,54 10,56 14,06 16,11 (2,86-12,28) (2,86-13,15) (4,33-15,49) (4,82-17,68) Power consumption W 1.090 (180-1.780) 1.640 (230-2.460) 2.100 (280-3.450) 3.100 (620-5.300) Operating current A 4.7 (0.8-7.9) 7,1 (1.0-10.7) 9.1 (1.2-15.0) 13.5 (2.8-23.6) 5.5 (1.1-9.1) 7.6 (2.2-10.9) 8.7 (2.5-12.4) Refrigerant / Charged quantity Power supply kg V/Ph/Hz Cooling capacity R410A / 4,3 R410A / 4,35 R410A / 3,8 220-240/1/50 314034 R410A / 4,6 380-420/3/50 3.200 4.380 5.020 (620-5.300) (1.200-6.010) (1.350-6.820) EER 3,23 3,22 3,35 3,40 3,30 3,21 3,21 SEER 5,6 5,6 6,5 6,0 5,6 - - Energy label cooling A+ A+ A++ A+ A+ - - kW 4,10 (0,99-4,68) 5,86 (1,08-7,37) 7,61 (1,32-9,41) 11,73 11,74 16,40 19,06 (3,80-13,15) (3,80-14,03) (4,91-18,27) (5,70-20,90) Power consumption W 1.070 (180-1.620) 1.580 (230-2.380) 2.030 (280-3.420) 3.250 (780-5.000) Operating current A 4.6 (0.8-7.0) 6.9 (1.0-10.3) 8.8 (1.2-14.9) 14.1 (3.5-22.2) 5.4 (1.3-8.6) 7.6 (2.1-10.7) 9,1 (2.5-12.7) COP 3,83 3,71 3,75 3,61 3,75 3,71 3,61 SCOP (Average) 3,8 3,8 3,8 3,8 3,8 - - A A A A A - - Heating capacity Energy label heating 3.130 4.420 5.280 (780-5.000) (1.170-5.910) (1.390-6.980) Indoor Unit Air flow rate (H/M/L) m3/h 1580/1.200 /1.000 800/710/560 1.950/1.650/1.400 2.250/1.850/1.650 Sound pressure level (H) dB(A) 37 42 45 48 48 50 50 Sound power level (H) dB(A) 54 59 62 65 65 67 67 Dimensions (Panel) LxWxH mm 570(647)x570(647) x260(50) 840(950)x840(950)x245(55) 840(950)x840(950) x287(55) Packing (Panel) LxWxH mm 655(715)x655(715) x290(123) 900(1.035)x900(1.035)x265(90) 900(1.035)x900(1.035) x292(90) Net/gross (Panel) weight kg 16(2,5)/ 19(4,5) 18(2,5)/ 21(4,5) 24(5)/ 28(8) 26,5(5)/30,5(8) 29(5)/33(8) 31(5)/34(8) Twin-rotary Outdoor Unit Type Rotary Rotary Twin-rotary Twin-rotary Twin-rotary Twin-rotary Sound pressure level (H) Compressor dB(A) 44 48 52 52 52 52 53 Sound power level (H) dB(A) 61 65 69 69 69 69 70 Dimensions LxWxH mm 760x285 x590 845x320 x700 900x315 x860 938x392x1.369 Packing LxWxH mm 887x355 x645 965x395 x755 1.043x395 x915 1.095x495x1.505 Net/gross weight Piping diameters 35,4/37,9 46/50 59/63 100/114 102/116 102/118 107/120 Liquid inch kg 6,35 (1/4”) 6,35 (1/4”) 9,52 (3/8”) 9,52 (3/8”) 9,52 (3/8”) 9,52 (3/8”) 9,52 (3/8”) Gas inch 9,52 (3/8”) 12,7 (1/2”) 15,9 (5/8”) 15,9 (5/8”) 15,9 (5/8”) 15,9 (5/8”) 15,9 (5/8”) Drainage mm 25 25 32 32 32 32 32 A 9,5 10 13 25 11 13 15 Max. input current Maximum lenght of the line m 20 30 50 65 65 65 65 Maximum height difference m 10 20 25 30 30 30 30 Outdoor temperature °C -15 ... +50 cooling / heating -15 ... +24 Nominal conditions Indoor unit Outdoor unit Piping lenght Level difference Cooling mode 27°C DB, 19°C WB 35°C DB 5m 0m Heating mode 20°C DB, 19°C WB 7°C DB, 6°C WB 5m 0m Seasonal efficiency according to EN 14825. Seasonal efficiency and energy labelling is not applicable to split systems with cooling capacity exceeding 12 kW. The sound pressure value may vary depending on ambient conditions. 33 | Ceiling/Floor Inverter High efficiency Split Ceiling/Floor Inverter High efficiency Split SYSPLIT CEILING EVO HP Features SYSPLIT CEILING EVO air conditioners are perfectly combined with any interior and are stylish with modern design. Advanced DC inverter control for the compressor, outdoor fan motor and indoor fan motor. Flexible installation, the unit can be installed hanged on the wall or ceiling suspended. High efficient and washable air filter included. Automatic distribution of the treated air in the horizontal and vertical directions. Compact, easy to install and maintain, can be even installed in a corner. Low noise level thanks to the improved shape of the impeller blades. The fresh air intake can fulfill air quality requirements and enhance occupants comfort. With the Auto-restart function the unit resume with the same settings before the electric power failure. Environment friendly R410A refrigerant. A Infrared remote controller SYSCONTROL RM 52 included; Wired remote SYSCONTROL WC 90 available as accessory. A A B Dimensions Wired controller SYSCONTROL WC 90 Art. no. 314139 (optional) Infrared remote control SYSCONTROL RM 52 (standard) SYSPLIT OUTDOOR size 12 to 24 C A D H H A size 36 to 60 H H SYSPLIT CEILING H E B E E C C D D D A 24 36 48 60 Model A 1.068 1.068 1.650 1.650 1.650 A 18 24 36 48 60 845 900 938 938 938 B 675 675 675 675 675 B C 235 235 235 235 235 C 560 335 590 634 634 634 333 404 404 D 983 983 1.565 1.565 1.565 D 404 360 355 448 448 E 220 220 220 220 220 448 E 312 302 368 368 368 F 320 315 392 392 392 H 700 860 1.369 1.369 1.369 B B E C D 18 F Model F F C H A A BB BB E 34 Ceiling/Floor Inverter High efficiency Split | Technical features Model Indoor unit SYSPLIT CEILING 18 EVO HP Q 24 EVO HP Q 36 EVO HP Q 36 EVO HP Q 48 EVO HP Q 60 EVO HP Q SYSPLIT OUTDOOR 18 EVO HP Q 24 EVO HP Q 36 EVO HP Q 36 EVO HP R 48 EVO HP R 60 EVO HP R Art. no. Indoor unit 314042 314043 314044 314044 314046 314048 Art. no. Outdoor unit 314057 314058 314059 314060 314062 314063 R410A / 2,2 R410A / 4,3 R410A / 4,35 R410A / 3,8 R410A / 4,6 Model Outdoor unit Refrigerant / Charged quantity Power supply kg R410A / 1,8 V/Ph/Hz 220-240/1/50 380-420/3/50 380-420/3/50 kW 5,29 (1,29-7,37) 7,07 (1,46-8,77) 10,56 (2,92-13,15) 10,55 (2,92-13,15) 14,07 (4,33-15,55) 16,41 (4,91-17,98) Power consumption W 1.450 (230-2.460) 2.070 (280-3.450) 3.080 (600-5.280) 2.770 (600-5.280) 4.380 (1.200-6.000) 5.110 (1.370-6.930) Operating current A 6.3 (1.0-10.7) Cooling capacity 4.8 (1.0-9.1) 7.6 (2.2-10.9) 8.8 (2.5-12.6) EER 3,65 3,40 3,43 3,81 3,21 3,21 SEER 6,2 6,6 6,0 6,5 - - Energy label cooling A++ A++ A+ A++ - - kW 5,85 (1,08-7,37) 7,6 (1,32-9,50) 11,71 (3,80-14,03) 11,72 (3,80-14,03) 16,40 (4,91-18,36) 19,05 (5,70-20,90) Power consumption W 1.410 (230-2.380) 1.900 (280-3.420) 3.140 (750-5.000) 2.930 (750-5.000) 4.420 (1.170-5.910) 5.280 (1.390-6.980) Operating current A Heating capacity 9.0 (1.2-15.0) 13.04 (2.7-23.5) 6.1 (1.0-10.3) 8.3 (1.2-14.9) 13,7 (3.3-22.2) 5.1 (1.3-8.6) 7.6 (2.1-10.7) 9.1 (2.5-12.7) COP 4,15 4,00 3,73 4,00 3,71 3,61 SCOP (Average) 3,8 3,8 3,8 3,8 - - A A A A - - 900/ 750/600 1.400/ 1.250/1.100 Energy label heating Indoor Unit Air flow rate (H/M/L) m3/h 2.200/1.850/1.500 2.300/1.900/1.700 Sound pressure level (H) dB(A) 43 46 47 48 50 50 Sound power level (H) dB(A) 60 63 64 65 67 67 Dimensions LxWxH mm 1.068x675x235 Packing LxWxH mm 1.145x755x313 Net/gross weight kg 1.650x675x235 1.725x755x313 25/31,5 25/30 40/46 40/46 40/46 40/46 Twin-rotary Outdoor Unit Type Rotary Twin-rotary Twin-rotary Twin-rotary Twin-rotary Sound pressure level (H) Compressor dB(A) 48 52 52 52 52 53 Sound power level (H) dB(A) 65 69 69 69 69 70 Dimensions LxWxH mm 845x320x700 900x315x860 938x392x1.369 Packing LxWxH mm 965x395 x755 1.043x395 x915 1.095x495x1.505 Net/gross weight Piping diameters 46/50 59/63 100/114 102/116 102/118 107/120 Liquid inch kg 6,35 (1/4”) 9,52 (3/8”) 9,52 (3/8”) 9,52 (3/8”) 9,52 (3/8”) 9,52 (3/8”) Gas inch 12,7 (1/2”) 15,9 (5/8”) 15,9 (5/8”) 15,9 (5/8”) 15,9 (5/8”) 15,9 (5/8”) Drainage mm 32 32 32 32 32 32 A 10 13 25 11 13 15 Max. input current Maximum lenght of the line m 30 50 65 65 65 65 Maximum height difference m 20 25 30 30 30 30 Outdoor temperature °C -15 ... +50 cooling / heating -15 ... +24 Nominal conditions Indoor unit Outdoor unit Piping lenght Level difference Cooling mode 27°C DB, 19°C WB 35°C DB 5m 0m Heating mode 20°C DB, 19°C WB 7°C DB, 6°C WB 5m 0m Seasonal efficiency according to EN 14825. Seasonal efficiency and energy labelling is not applicable to split systems with cooling capacity exceeding 12 kW. The sound pressure value may vary depending on ambient conditions. 35 | Duct Inverter High efficiency Split Duct Inverter High efficiency Split SYSPLIT DUCT EVO HP Features SYSPLIT DUCT EVO air conditioners are designed using the latest engineering solutions and allow their installation with a minimum ceiling height. Advanced DC inverter control for the compressor, outdoor fan motor and indoor fan motor. One indoor unit can serve several facilities through a network of ducts to the high external static pressure. Air conditioners are equipped with washable air filter. Flexible air intake from the rear (factory standard), it can be easily changed to bottom air intake using the same flange plate. The fresh air hole on the side of the unit makes easy the connection to the external air intake. Built-in drain pump can lift the condensate water up to 750 mm. With the Auto-restart function the unit resumes with the same settings before the electric power failure. Environment friendly R410A refrigerant. Wired remote controller SYSCONTROL WC 90 included; Infrared remote control SYSCONTROL RM 52 Art. no. 314137 (optional) Wired controller SYSCONTROL WC 90 (standard) Infrared remote controller SYSCONTROL RM 52 available as accessory. A A G Dimensions A H A E E C C D D 12 18 24 36 48 60 760 845 900 938 938 938 530 E C D A 18 24 36 48 60 Model 560 590 634 634 634 290 335 333 404 404 404 D 315 360 355 448 448 448 80 E 270 312 302 368 368 368 968 968 F 285 320 315 392 392 392 40 40 40 H 590 700 860 1.369 1.369 1.369 204 204 204 A 700 920 920 1.200 1.200 1.200 A B 210 270 270 300 300 300 B C 635 635 635 865 865 865 C D 570 570 570 800 800 800 E 65 65 65 80 80 F 493 716 716 968 G 35 35 35 H 119 179 179 B B F D 12 C F F D C H A A BB BB Model A H H F E size 36 to 60 B F E Outdoor unit size 12 to 24 H H G B H SYSPLIT DUCT H 36 Duct Inverter High efficiency Split | Technical features SYSPLIT DUCT 12 EVO HP Q 18 EVO HP Q 24 EVO HP Q 36 EVO HP Q 36 EVO HP Q 48 EVO HP Q 60 EVO HP Q SYSPLIT OUTDOOR 12 EVO HP Q 18 EVO HP Q 24 EVO HP Q 36 EVO HP Q 36 EVO HP R 48 EVO HP R 60 EVO HP R Model Indoor unit Model Outdoor unit Art. no. Indoor unit 314026 314027 314022 314023 314023 314045 314047 Art. no. Outdoor unit 314056 314057 314058 314059 314060 314062 314063 R410A / 1,1 R410A / 1,8 R410A / 2,2 Refrigerant / Charged quantity Power supply kg V/Ph/Hz R410A / 4,3 R410A / 4,35 R410A / 3,8 380420/3/50 220-240/1/50 R410A / 4,6 380-420/3/50 kW 3,51 (1,11-4,59) 5,27 (1,29-7,37) 7,02 (1,48-8,77) 10,56 10,56 14,06 16,69 (2,92-13,15) (2,92-13,15) (4,33-15,64) (4,97-18,27) Power consumption W 1.080 (180-1.820) 1.460 (230-2.460) 2.060 (280-3.450) 3.290 (620-5.300) Operating current A 4.7 (0.8-7.9) 6.3 (1.0-10.7) 9.0 (1.2-15.0) 14.3 (2.8-23.6) 4.8 (1.1-9.1) 7.6 (2.2-10.9) 9.0 (2.5-12.8) EER 3,25 3,61 3,41 3,21 3,80 3,21 3,21 SEER 5,3 6,4 6,7 6,0 6,1 - - A A++ A++ A+ A++ - - kW 4,11 (0,99-4,68) 5,87 (1,08-7,37) 7,61 (1,32-9,50) 11,72 (3,8-14,03) 11,72 (3,8-14,03) Power consumption W 1.080 (180-1.620) 1.450 (230-2.380) 1.950 (280-3.420) 3.160 (780-5.000) 2.790 4.560 5.220 (780-5.000) (1.180-5.920) (1.390-6.990) Operating current A 4.7 (0.8-7.0) 6.3 (1.0-10.3) 8.5 (1.2-14.9) 13.7 (3.5-22.2) 4.8 (1.3-8.6) 7.9 (2.2-10.7) 9.0 (2.5-12.7) COP 3,81 4,05 3,90 3,71 4,20 3,73 3,65 SCOP (Average) 3,8 3,8 3,8 3,8 3,8 - - A A A A A - - 800/ 610/520 1.180/ 770/650 1.400/ 1.100/1.000 Cooling capacity Energy label cooling Heating capacity Energy label heating 2.780 4.380 5.200 (620-5.300) (1.200-6.000) (1.380-7.050) 17,01 19,05 (4,97-18,56) (5,79-21,05) Indoor Unit Air flow rate (H/M/L) External static pressure (Max) m3/h 2.270/1.890/1.650 3.010/2.410/1.940 Pa 40 70 70 80 80 100 Sound pressure level (H) dB(A) 40 42 46 45 44 46 100 46 Sound power level (H) dB(A) 57 59 63 62 61 63 63 Dimensions LxWxH mm 700x 635x210 920x635x270 1.200x865x300 Packing LxWxH mm 915x 655x290 1.135x655x350 1.385x920x373 kg 18,1/22,8 28/31,5 28/31,5 44/52,5 44/52,5 44/55 45/53 Twin-rotary Net/gross weight Outdoor Unit Type Rotary Rotary Twin-rotary Twin-rotary Twin-rotary Twin-rotary Sound pressure level (H) Compressor dB(A) 44 48 52 52 52 52 53 Sound power level (H) dB(A) 61 65 69 69 67 69 70 Dimensions LxWxH mm 760x 285x590 845x 320x700 900x 315x860 938x392x1369 Packing LxWxH mm 887x 355x645 965x 395x755 1.043x 395x915 1.095x495x1.505 Unit weight 35,4/37,9 46/50 59/63 100/114 102/116 102/118 107/120 Liquid inch 6,35 (1/4”) 6,35 (1/4”) 9,52 (3/8”) 9,52 (3/8”) 9,52 (3/8”) 9,52 (3/8”) 9,52 (3/8”) Gas inch 9,52 (3/8”) 12,7 (1/2”) 15,9 (5/8”) 15,9 (5/8”) 15,9 (5/8”) 15,9 (5/8”) 15,9 (5/8”) Drainage mm 25 25 25 25 25 25 25 Max. input current A 9,5 10 13 25 11 13 15 Maximum lenght of the line m 20 30 50 65 65 65 65 Maximum height difference m 10 20 25 30 30 30 30 Outdoor temperature °C Piping diameters kg -15 ... +50 cooling / heating -15 ... +24 Nominal conditions Indoor unit Outdoor unit Piping lenght Level difference Cooling mode 27°C DB, 19°C WB 35°C DB 5m 0m Heating mode 20°C DB, 19°C WB 7°C DB, 6°C WB 5m 0m Seasonal efficiency according to EN 14825. Seasonal efficiency and energy labelling is not applicable to split systems with cooling capacity exceeding 12 kW. The sound pressure value may vary depending on ambient conditions. 37 | Duct On/Off Split Duct On/Off Split SYSPLIT DUCT HT Features SYSPLIT DUCT HT air conditioners are suitable for large commercial spaces providing highest cooling/heating capacity and powerfull air flow. One indoor unit can serve several facilities through a network of ducts. High external static pressure up to 200 Pa. Air conditioners are equipped with washable air filter. Environment friendly R410A refrigerant. Cooling operation with outdoor temperature up to +52°C. With the Auto-restart function the unit resumes with the same settings before the electric power failure Environment friendly R410A refrigerant. Wired remote controller SYSCONTROL WC 90 included; Infrared remote controller SYSCONTROL RM 52 available as accessory. Dimensions 5 330 656 469 76 1350 0 330 450 5 800 840 762 908 676 700 507 106 120 57 179 180 30 1260 45 638 330 654 SYSPLIT OUTDOOR 120 HTR 858 330 SYSPLIT OUTDOOR 120 HT R 45 SYSPLIT DUCT 120 HT Q 330 1895 Wired controller SYSCONTROL WC 90 (standard) SYSPLIT OUTDOOR 76/96 HT R 1260 180 26 1205 1828 Infrared remote control SYSCONTROL RM 52 Art. no. 314137 (optional) SYSPLIT OUTDOOR 76/96 HT R SYSPLIT DUCT 76/96 HT Q 231 132 38 24 750 908 654 762 700 15 677 519 737 676 Duct On/Off Split | Technical features Model Indoor unit SYSPLIT DUCT 76 HT Q 96 HT Q 120 HT Q SYSPLIT OUTDOOR 76 HT R 96 HT R 120 HT R Art. no. Indoor unit 314070 314071 314072 Art. no. Outdoor unit 314179 314180 314181 R410A / 5,4 R410A / 6,0 R410A / 7,2 Model Outdoor unit Refrigerant / Charged quantity kg Power supply V/Ph/Hz Cooling capacity 380-415/3/50 kW 22,0 28,0 35,0 Power consumption W 7.500 9.600 12.000 Rated current A 19,3 23,7 28,6 2,93 2,92 2,92 kW 25,0 31,0 38,0 Power consumption W 8.300 10.300 12.600 Rated current A 21,3 26,5 31,5 3,01 3,01 3,02 4.250/3.760/3.220 5.100/4.410/3.760 EER Heating capacity COP Indoor Unit Power supply V/Ph/Hz m3/h Air flow rate (H/M/L) External static pressure (Hi) 220-240/1/50 Pa Sound pressure level (H) 6.375/5.920/5.430 200 dB(A) 150 53 54 56 Dimensions (LxWxH) mm 1.350x760x450 1.828x858x638 Packing LxWxH mm 1.549x917x476 2.095x929x689 105/120 188/220 Net/gross weight kg Outdoor Unit Power supply V/Ph/Hz 380-415/3/50 Compressor Type Scroll Scroll Scroll Air flow rate m3/h 7.200 10.400 12.000 dB(A) 65 67 69 Sound pressure level (Hi) Dimensions (LxWxH) mm Packing LxWxH mm Net/gross weight Piping diameters kg Liquid inch Gas inch Drainage mm Locked rotor amp A Maximum lenght of the line m 1.260x908x700 1.320x1.060x730 174/193 187/204 201/217 9,52 (3/8”) 22,2 (7/8”) 12,7 (1/2”) 25,4 (1”) 28,6 (1 1/8”) 41 110 110 147 50 Maximum height difference m 30 Outdoor temperature °C +21 ... +52 cooling / heating -10 ... +24 Fan performance SYSPLIT DUCT 120 HT Q 260 240 Med Hi Lo 220 200 180 160 140 120 100 80 60 40 20 0 3500 3750 4000 4250 4500 4750 5000 5250 5500 5750 6000 Air Flow(m3/h) 200 Lo 180 Static Pressure (Pa) 260 240 Hi Lo Med 220 200 180 160 140 120 100 80 60 40 20 0 2750 3000 3250 3500 3750 4000 4250 4500 4750 5000 5250 SYSPLIT DUCT 96 HT Q Static Pressure (Pa) Static Pressure(Pa) SYSPLIT DUCT 76 HT Q Med Hi 160 140 120 100 80 60 40 20 0 4250 4750 5250 Air Flow (m3/h) 5750 6250 Air Flow (m3/h) 6750 7250 Nominal conditions Indoor unit Outdoor unit Piping lenght Level difference Cooling mode 27°C DB, 19°C WB 35°C DB 5m 0m Heating mode 20°C DB, 19°C WB 7°C DB, 6°C WB 5m 0m The sound pressure value may vary depending on ambient conditions. 7750 39 40 | VRF systems SYSVRF VRF systems | SYSVRF multi-zone solutions: light commercial and commercial VRF systems The SYSVRF modular systems are most valuable for room space from 100 to 1000 sq.m. with large independence of climatic zones - hotels, restaurants, retail, office buildings, etc. Up to 4 modular outdoor units can be combined in one single refrigerant system thus reaching up to 200kW of cooling capacity and connecting up to 64 indoor units. In the same system they are able to fulfill the increasing demands of air comfort still having low operating costs. All SYSVRF systems are equipped with DC Inverter compressors and DC Inverter fans which gives enhanced system performance and very low operating noise. The new generation of 3-pipe systems are equipped with all DC Inverter compressor which delivers outstanding comfort pleasure and reduces tremendously the electricity consumption. SYSVRF of Systemair are available with different configurations: the typical heat pump Mini and Modular 2-pipe outdoor units Air-cooled or Water-cooled and the superior Modular heat recovery 3-pipe units. SYSVRF Mini and SYSVRF Modular systems SYSVRF AIR EVO HP Mini 44 SYSVRF DUCT 72 SYSVRF AIR EVO HP 46 SYSVRF DUCT HP 74 SYSVRF AIR EVO HR 50 SYSVRF FLOOR EB 76 SYSVRF WATER EVO HP 56 SYSVRF FLOOR CB 78 SYSVRF WALL 60 SYSVRF HRV 80 SYSVRF CASSETTE MINI 62 SYSCONTROL AHU 82 SYSVRF CASSETTE 64 SYSVRF selection software 83 SYSVRF CASSETTE 1 WAY 66 SYSCONTROL systems 84 SYSVRF CASSETTE 2 WAY 68 SYSVRF JOINT accessories 86 SYSVRF CEILING 70 41 42 | VRF systems VRF Systemair- SYSVRF Multi-zone air conditioning system VRF systems are most beneficial for space up to 15002000 sq.m. with large independence of climatic zones – hotels, restaurants, retail space, office buildings, etc. In the same system they are able to fulfill the increasing demands of the parameters of air in each room and still have low operating costs. The most comfortable temperature An important advantage of the multi-zone air-conditioning is a smooth and rapid achievement of a comfortable temperature, as well as maintaining the specified parameters accurate to ± 0,5 °C. Such high performance was achieved thanks to an accurate control of the refrigerant flow and the mechanism of redistribution of refrigerant between the several units, implemented with the help of electronic expansion valves. High energy efficiency The efficiency of multi-zone systems is very high, because each time the electric power is consumed as much as necessary to carry out user requirements. If the indoor units work only in a few areas of the building, then the power consumption is reduced proportionally by changing the refrigerant flow. Low noise Low noise of both outdoor and indoor units makes the job a multizone system virtually inconspicuous. A balanced lineup The lineup of multizone VRF series are continuously optimized. In response to market demands Systemair offers several types and sizes of indoor units: wallmounted, cassette, floor-ceiling and duct. Outdoor units Mini, despite the compact dimensions , solve different tasks of air conditioning on small objects. Six modular outdoor units can be combined in one refrigerant system thus reaching a total cooling capacity of up to 200 kW. Separately, to highlight the 3 Pipe heat recovery system for indipendent and simultaneous cooling and heating operation. Continuous development in the field of management In modern air-conditioning systems the demand for automation and control systems integrated with other infrastructure building systems is continuously increasing. These are exactly the principles on the basic of the development of the control systems of Systemair. In addition to the traditional control systems of air conditioning, the user deals with different possibilities of control that can solve the various needs of the building management such as the possibility of control via personal computer and Internet network connection. Simplicity of design Systemair provides full integration and coordination of all elements of a multizone system, greatly simplifies the task of the designer. The selection process can be performed in maximum short period of time by using a simple and complete selection and designing software. VRF systems | SYSVRF lineup In 2014 Systemair has launched a new generation of VRF multi-zone systems - the SYSVRF series. The basis principle of work lies on the advantages of the DC Inverter technology and scroll compressors and the achieved results far exceed the high standards set by the industry. Through the use of modern technologies and implementation of their own development has significantly improved energy efficiency and decreased the noise level, with compact dimensions, increased ease of installation and maintenance, greatly expanded the range of application from light commercial to large commercial spaces. SYSVRF outdoor units SYSVRF mini 2 Pipe Heat Pump 12,0-16,0 kW SYSVRF AIR EVO HR Modular 3 Pipe Heat Recovery 25,0-180,0 kW SYSVRF AIR EVO HP Modular 2 Pipe Heat Pump 25,0 - 200,0 kW SYSVRF WATER EVO HP Modular 2 Pipe Heat Pump 25,0 - 100,0 kW SYSVRF WALL SYSVRF CEILING SYSVRF CASSETTE MINI SYSVRF Indoor units 1,5-5,6 kW SYSVRF CASSETTE 2,8-14,0 kW SYSVRF DUCT 3,6-14,0 kW SYSVRF CASSETTE 1 WAY 1,8-3,6 kW SYSVRF DUCT HP 2,2-5,6 kW SYSVRF CASSETTE 2 WAY 2,2-5,6 kW SYSVRF HRV 2,2-14,0 kW 7,1-28,0 kW 500-2.000 m3/h SYSVRF FLOOR EB SYSVRF FLOOR CB SYSCONTROL AHU 2,2-8,0 kW 2,2-8,0 kW 9,0-56 kW Compatible outdoor and indoor series Outdoor units of the SYSVRF Mini, Heat Pump and Heat Recovery series are compatible with all types of SYSVRF indoor units. There are 10 different types of indoor units available with capacity from 1,5 kW to 28,0 kW, making the total number of indoor units equal to 63 different types and capacities. The ventilation function can be provided through the SYSVRF HRV units or through the combination of a Systemair air handling unit with the control module SYSCONTROL AHU. 43 | Mini VRF Mini VRF Heat Pump Outdoor Units SYSVRF AIR EVO HP Features Full DC Inverter Mini VRF with DC Inverter compressor and DC fan motor. Compact size and long piping system. High efficiency at partial load. Inverter Rotary compressor providing wide capacity output from 10% to 100% evenly. Centralized control, BMS connection and web access potential. Hydrophilic Blue Fin coil enhances durability and protection against corrosion. Piping connection in four different directions makes simple the installation of outdoor unit. Maximum 7 indoor units connection. Indoor unit combination total capacity index from 45% to 130%. H Dimensions A F E D B C 44 Model 120 140 160 A 900 900 900 B 600 600 600 C 348 348 348 D 320 320 320 E 400 400 400 F 360 360 360 H 1.327 1.327 1.327 Mini VRF | Technical features Model Indoor unit SYSVRF 120 AIR EVO HP Q 140 AIR EVO HP R 160 AIR EVO HP R 314089 314092 314094 Art. no. Power Supply V/Ph/Hz 220-240/1/50 380-415/3/50 Cooling capacity kW 12,3 14,0 15,5 Power Input kW 3,25 3,95 4,52 3,78 3,54 3,43 Heating capacity kW 13,2 15,4 17,0 Power Input kW 3,47 4,16 4,77 3,80 3,70 EER COP Max. current Compressor Inverter Rotary A Quantity 12 pcs 1 Power Input W 3.010 3.010 4.240 Refrigerant oil ml 870+630 870+630 1.400+250 Outdoor fan type / motor 2 Axial / 2 DC fan motors m3/h Air flow Sound pressure level Refrigerant 6.000 dB(A) 57 Type R410A Refrigerant charge kg Dimension LxWxH mm Packing LxWxH mm Net/gross weight Piping dimension 3,56 36 3,3 mm (in) Gas pipe mm (in) Max qty. indoor units connection pcs Operating ambient temp. range °C 3,9 1.030x435x1.456 kg Liquid pipe 3,9 900x320x1.327 95/106 95/106 102/113 9,5 (3/8”) 15,9 (5/8”) 6 6 7 Cooling -15 ... +48 / Heating -15 ... +27 Nominal conditions Indoor unit Outdoor unit Piping lenght Level difference Cooling mode 27°C DB, 19°C WB 35°C DB 5m 0m Heating mode 20°C DB, 19°C WB 7°C DB, 6°C WB 5m 0m The sound pressure value may vary depending on ambient conditions. Piping Lenght Maximum piping equivalent lenght. Maximum piping (the farthest IDU from the first indoor unit branch) equivalent lenght. 100 m Maximum outdoor unit-indoor unit drop height. 30 m Maximum indoor unit to indoor unit drop height. 20 m Outdoor units SYSVRF AIR EVO HP Permitted value Total piping lenght (actual) Piping lenght Maximum piping 100 m Actual lenght 60 m Equivavent lenght 70 m Piping (the farthest IDU from the first indoor unit branch) equivalent lenght Drop height 8m Outdoor unit-indoor unit drop height Indoor unit to indoor unit drop height 20 m Outdoor unit up 30 m Outdoor unit down 20 m 8m 45 | VRF Heat Pump Modular VRF Heat Pump Outdoor Units SYSVRF AIR EVO HP SYSVRF 252-280 AIR EVO HP R Features Wide application area due to incredible piping lenght and wide operating temperature range. Free modular combination of 6 basic units, up to a total capacity of maximum 200 kW. Top class energy efficiency. DC Inverter Scroll compressor provinding wide capacity output from 10% to 100% evenly. All DC fan motor. High performance of the new designed heat exchanger. External static pressure up to 60 Pa (factory option, 20 Pa standard). Maximum 64 indoor unit connection. Indoor unit combination total capacity index from 50% to 130%. Centralized control, BMS connection and web access potential. SYSVRF 335-400-450 AIR EVO HP R SYSVRF 500 AIR EVO HP R Dimensions SYSVRF 252/280 AIR EVO HP R SYSVRF 335/400/450/500 AIR EVO HP R 1615 1615 1250 765 960 765 46 VRF Heat Pump | Technical features Model Indoor unit SYSVRF Art. no. Power Supply 252 AIR EVO HP R 280 AIR EVO HP R 335 AIR EVO HP R 400 AIR EVO HP R 450 AIR EVO HP R 500 AIR EVO HP R 314259 314260 314251 314252 314253 314254 V/Ph/Hz 380-415/3/50 Cooling capacity kW 25,2 28,0 33,5 40,0 45,0 50,0 Power Input kW 5,88 7,20 9,05 12,31 14,02 15,20 EER 4,29 3,89 3,7 3,25 3,21 3,29 Heating capacity kW 27,0 31,5 37,5 45,0 50,0 56,0 Power Input kW 6,15 7,61 8,99 11,19 12,79 14,25 4,39 4,14 4,17 4,02 3,91 3,93 20,8 22,1 23,7 31,8 32,8 35,4 COP Max. current Compressor Inverter Scroll Compressor Fixed Scroll A Quantity pcs 1 Capacity W 31.590 31.590 11.800 31.590 31.590 31.590 Refrigerant oil ml 500 500 500 500 500 500 Quantity pcs - - 1 1 1 1 Capacity W - - 17.100 13.390 13.390 20.900 Refrigerant oil ml - - 500 500 500 500 Outdoor fan type / motor 1 Axial / 1 DC fan motor Air flow Sound pressure level Refrigerant m3/h 11.500 15.100 dB(A) 57 59 Type 15.600 15.600 15.600 60 61 13 16 R410A Refrigerant charge kg 9 Dimension (LxWxH) mm 960x765x1.615 Packing (LxWxH) mm 1.025x830x1.790 Net/gross weight kg Piping dimension 2 Axial / 2 DC fan motors 11 1.250x765x1.615 1.305x825x1.790 198/213 266/288 280/300 300/320 Liquid pipe mm (in) 12,7 (1/2”) 15,9 (5/8”) 19,1 (3/4”) Gas pipe mm (in) 25,4 (1”) 31,8 (1 1/4”) 31,8 (1 1/4”) Oil balance pipe mm (in) Operating ambient temp. range 6,35 (1/4”) °C Cooling -5 ... +48 / Heating -20 ... +24 Nominal conditions Indoor unit Outdoor unit Piping lenght Level difference Cooling mode 27°C DB, 19°C WB 35°C DB 5m 0m Heating mode 20°C DB, 19°C WB 7°C DB, 6°C WB 5m 0m The sound pressure value may vary depending on ambient conditions. Piping Lenght Maximum piping equivalent lenght. Maximum piping (the farthest IDU from the first indoor unit branch) equivalent lenght. Maximum outdoor unit-indoor unit drop height. Maximum indoor unit to indoor unit drop height. Outdoor units SYSVRF 252 to 2000 AIR EVO HP R Permitted value Total piping lenght (actual) Piping lenght Maximum piping 1.000 m Actual lenght 175 m Equivavent lenght 200 m Piping (the farthest IDU from the first indoor unit branch) equivalent lenght Drop height Outdoor unit-indoor unit drop height Outdoor unit down Outdoor unit up Indoor unit to indoor unit drop height * When the farthest pipe length is more than 40m, it needs to meet specific conditions according to the installation part of the technical manual. ** Level difference: less or equal to 50m is standard; more than 50m is available to be customized. 40 m/90 m* 110 m 50 m/70 m** 30 m 47 48 | VRF Heat Pump combination Outdoor unit combination SYSVRF AIR EVO HP Design Cooling/ Heating capacity kW Model Recommended combination Outdoor branch Max. indoor unit qty 25,2/27 SYSVRF 252 AIR EVO HP R SYSVRF 252 AIR EVO HP R - 13 28/31,5 SYSVRF 280 AIR EVO HP R SYSVRF 280 AIR EVO HP R - 16 33,5/37,5 SYSVRF 335 AIR EVO HP R SYSVRF 335 AIR EVO HP R - 20 40/45 SYSVRF 400 AIR EVO HP R SYSVRF 400 AIR EVO HP R - 23 45/50 SYSVRF 450 AIR EVO HP R SYSVRF 450 AIR EVO HP R - 26 50/56 SYSVRF 500 AIR EVO HP R SYSVRF 500 AIR EVO HP R - 29 56/63 SYSVRF 560 AIR EVO HP R SYSVRF 280 AIR EVO HP R x2 SYSVRF JOINT OUT 02 HP 33 61,5/69 SYSVRF 615 AIR EVO HP R SYSVRF 280 AIR EVO HP R + SYSVRF 335 AIR EVO HP R SYSVRF JOINT OUT 02 HP 36 68/76,5 SYSVRF 680 AIR EVO HP R SYSVRF 280 AIR EVO HP R + SYSVRF 400 AIR EVO HP R SYSVRF JOINT OUT 02 HP 39 73/81,5 SYSVRF 730 AIR EVO HP R SYSVRF 280 AIR EVO HP R + SYSVRF 450 AIR EVO HP R SYSVRF JOINT OUT 02 HP 43 78/87,5 SYSVRF 780 AIR EVO HP R SYSVRF 280 AIR EVO HP R + SYSVRF 500 AIR EVO HP R SYSVRF JOINT OUT 02 HP 46 85/95 SYSVRF 850 AIR EVO HP R SYSVRF 400 AIR EVO HP R + SYSVRF 450 AIR EVO HP R SYSVRF JOINT OUT 02 HP 50 90/101 SYSVRF 900 AIR EVO HP R SYSVRF 400 AIR EVO HP R + SYSVRF 500 AIR EVO HP R SYSVRF JOINT OUT 02 HP 53 95/106 SYSVRF 950 AIR EVO HP R SYSVRF 450 AIR EVO HP R + SYSVRF 500 AIR EVO HP R SYSVRF JOINT OUT 02 HP 56 100/112 SYSVRF 1000 AIR EVO HP R SYSVRF 500 AIR EVO HP R x2 SYSVRF JOINT OUT 02 HP 59 VRF Heat Pump combination | Design Cooling/ Heating capacity kW Model Recommended combination Outdoor branch Max. indoor unit qty 106/119 SYSVRF 1060 AIR EVO HP R SYSVRF 280 AIR EVO HP R x2 + SYSVRF 500 AIR EVO HP R SYSVRF JOINT OUT 03 HP 63 113/126,5 SYSVRF 1130 AIR EVO HP R SYSVRF 280 AIR EVO HP R + SYSVRF 400 AIR EVO HP R + SYSVRF 450 AIR EVO HP R SYSVRF JOINT OUT 03 HP 64 120/135 SYSVRF 1200 AIR EVO HP R SYSVRF 400 AIR EVO HP R x3 SYSVRF JOINT OUT 03 HP 64 123/137,5 SYSVRF 1230 AIR EVO HP R SYSVRF 280 AIR EVO HP R + SYSVRF 450 AIR EVO HP R + SYSVRF 500 AIR EVO HP R SYSVRF JOINT OUT 03 HP 64 128/143,5 SYSVRF 1280 AIR EVO HP R SYSVRF 280 AIR EVO HP R + SYSVRF 500 AIR EVO HP R x2 SYSVRF JOINT OUT 03 HP 64 135/151 SYSVRF 1350 AIR EVO HP R SYSVRF 400 AIR EVO HP R + SYSVRF 450 AIR EVO HP R + SYSVRF 500 AIR EVO HP R SYSVRF JOINT OUT 03 HP 64 140/157 SYSVRF 1400 AIR EVO HP R SYSVRF 400 AIR EVO HP R + SYSVRF 500 AIR EVO HP R x2 SYSVRF JOINT OUT 03 HP 64 145/162 SYSVRF 1450 AIR EVO HP R SYSVRF 450 AIR EVO HP R + SYSVRF 500 AIR EVO HP R x2 SYSVRF JOINT OUT 03 HP 64 150/168 SYSVRF 1500 AIR EVO HP R SYSVRF 500 AIR EVO HP R x3 SYSVRF JOINT OUT 03 HP 64 156/175 SYSVRF 1560 AIR EVO HP R SYSVRF 280 AIR EVO HP R x2 + SYSVRF 500 AIR EVO HP R x2 SYSVRF JOINT OUT 04 HP 64 163/182,5 SYSVRF 1630 AIR EVO HP R SYSVRF 280 AIR EVO HP R + SYSVRF 400 AIR EVO HP R + SYSVRF 450 AIR EVO HP R + SYSVRF 500 AIR EVO HP R SYSVRF JOINT OUT 04 HP 64 168/188,5 SYSVRF 1680 AIR EVO HP R SYSVRF 280 AIR EVO HP R + SYSVRF 400 AIR EVO HP R + SYSVRF 500 AIR EVO HP R x 2 SYSVRF JOINT OUT 04 HP 64 173/193,5 SYSVRF 1730 AIR EVO HP R SYSVRF 280 AIR EVO HP R + SYSVRF 450 AIR EVO HP R + SYSVRF 500 AIR EVO HP R x 2 SYSVRF JOINT OUT 04 HP 64 178/199,5 SYSVRF 1780 AIR EVO HP R SYSVRF 280 AIR EVO HP R + SYSVRF 500 AIR EVO HP R x 3 SYSVRF JOINT OUT 04 HP 64 185/207 SYSVRF 1850 AIR EVO HP R SYSVRF 400 AIR EVO HP R + SYSVRF 450 AIR EVO HP R + SYSVRF 500 AIR EVO HP R x 2 SYSVRF JOINT OUT 04 HP 64 190/213 SYSVRF 1900 AIR EVO HP R SYSVRF 400 AIR EVO HP R + SYSVRF 500 AIR EVO HP R x 3 SYSVRF JOINT OUT 04 HP 64 195/218 SYSVRF 1950 AIR EVO HP R SYSVRF 450 AIR EVO HP R + SYSVRF 500 AIR EVO HP R x 3 SYSVRF JOINT OUT 04 HP 64 200/224 SYSVRF 2000 AIR EVO HP R SYSVRF 500 AIR EVO HP R x 4 SYSVRF JOINT OUT 04 HP 64 49 | VRF Heat Recovery Modular VRF Heat Recovery Outdoor Units SYSVRF AIR EVO HR Features Simultaneous operation in cooling and heating mode provides more comfort and reduces power consumption. Wide application area due to incredible piping lenght and wide operating temperature range. Free modular combination of 5 basic units, up to a total capacity of maximum 180 kW. Top class energy efficiency. All DC Inverter Scroll compressors providing wide capacity output from 10% to 100% evenly. DC fan motor. High performance of the new designed heat exchanger with double refrigerant circuit. External static pressure up to 40 Pa (20 Pa standard). Maximum 64 indoor unit connection. Indoor unit combination total capacity index from 50% to 130%. Centralized control, BMS connection and web access potential. Continous heating output during defrost operation thanks to the innovative double heat exchanger. 1250 Dimensions 1615 SYSVRF 252/280/335/400/450 AIR EVO HR R 765 1615 1250 765 50 VRF Heat Recovery | Technical features Model Indoor unit SYSVRF Art. no. Power Supply 252 AIR EVO HR R 280 AIR EVO HR R 335 AIR EVO HR R 400 AIR EVO HR R 450 AIR EVO HR R 314084 314085 314086 314087 314088 V/Ph/Hz 380-415/3/50, 380-415/3/60 Cooling capacity kW 25,2 28,0 33,5 40,0 45,0 Power Input kW 5,73 6,67 8,07 11,30 13,24 3,40 EER 4,40 4,20 4,15 3,54 Heating capacity kW 27,0 31,5 37,5 45,0 50,0 Power Input kW 6,00 7,33 8,72 11,19 12,79 COP Max. current Compressor Inverter Scroll A 4,30 4,30 4,02 3,91 20,8 22,1 22,8 31,8 32,8 2 2 Quantity pcs 1 1 1 Capacity W 31.590 31.590 31.590 Refrigerant oil ml m3/h Air flow Sound pressure level Refrigerant 4,50 31.590+11.800 500 500 500 12.000 12.000 13.000 15.000 15.000 58 60 60 dB(A) 57 Type 500+500 R410A Refrigerant charge kg 10 10 10 14 Dimension (LxWxH) mm 1.250x765x1.615 1.250x765x1.615 Packing (LxWxH) mm 1.305x825x1.790 1.350x825x1.790 Net/gross weight kg Piping dimension 255/273 303/322 Liquid pipe mm (in) 9,5 (3/8”) 12,7 (1/2”) 12,7 (1/2”) 15,9 (5/8”) 15,9 (5/8”) Low pressure gas pipe mm (in) 22,2 (7/8”) 22,2 (7/8”) 25,4 (1”) 28,6 (1 1/8”) 28,6 (1 1/8”) High pressure gas pipe mm (in) 19,1 (3/4”) 19,1 (3/4”) 19,1 (3/4”) 19,1 (3/4”) 19,1 (3/4”) Oil balance pipe mm (in) 19,1 (3/4”) 19,1 (3/4”) 19,1 (3/4”) 22,2 (7/8”) 22,2 (7/8”) Gas balance pipe mm (in) 6,0 (1/4”) 6,0 (1/4”) 6,0 (1/4”) 6,0 (1/4”) 6,0 (1/4”) Operating ambient temp. range °C Cooling -5...+48 / Heating -20...+24 / Simultaneous Cooling and Heating -5...+24 Nominal conditions Indoor unit Outdoor unit Piping lenght Level difference Cooling mode 27°C DB, 19°C WB 35°C DB 7,5 m 0m Heating mode 20°C DB, 15°C WB 7°C 7,5 m 0m The sound pressure value may vary depending on ambient conditions. Piping Lenght Maximum piping equivalent lenght. Maximum piping (the farthest IDU from the first indoor unit branch) equivalent lenght. Maximum outdoor unit-indoor unit drop height. Maximum indoor unit to indoor unit drop height. Outdoor units SYSVRF 252 to 1800 AIR EVO HR R Permitted value Total piping lenght (actual) Piping lenght Maximum piping 1.000 m Actual lenght 175 m Aquivavent lenght 200 m Piping (the farthest IDU from the first indoor unit branch) equivalent lenght Drop height Outdoor unit-indoor unit drop height Outdoor unit up Outdoor unit down Indoor unit to indoor unit drop height * When the farthest pipe length is more than 40m, it needs to meet specific conditions according to the installation part of the technical manual. ** Level difference: less or equal to 50m is standard; more than 50m is available to be customized. 40 m/90 m* 110 m 50 m/70 m** 30 m 51 52 | VRF Heat Recovery switch module Mode Switch module for VRF Heat Recovery systems SYSVRF BOX HR Features SYSVRF BOX 02 HR Simultaneous heating and cooling in a single refrigerant system thanks to the combination of SYSVRF HR outdoor units and the SYSVRF BOX modules. SYSVRF BOX HR is available in 3 different modules with 2, 4 or 6 outlets and combination up to 24 indoor units from a single module. SYSVRF BOX 02-1 HR and 04-1 HR can connect only one indoor unit and they are specifically designed for the combination with SYSCONTROL AHU and Systemair air handling units. Compact and light design, it can be installed in narrow space. Heating Heating Heating SYSVRF BOX 06 HR SYSVRF BOX 04 HR Independent sub-cooling circuit for each SYSVRF BOX HR module. Off Cooling Cooling Dimensions SYSVRF BOX SYSVRF BOX 02 HR SYSVRF BOX 04 HR SYSVRF BOX 06 HR A 630 960 960 B 600 600 600 C 225 225 225 D 490 820 820 E 300 300 300 VRF Heat Recovery switch module | Technical features SYSVRF BOX 02 HR Model Art. no. 314161 Power Supply V/Ph/Hz SYSVRF BOX 04 HR SYSVRF BOX 06 HR 314162 314186 220-240/1/50 Max indoor unit groups 2 4 6 Max number of each group indoor units 4 4 4 4x6=24 4x2=8 4x4=16 Max capacity of each group indoor units Max number of all downstream indoor units kW 16 16 16 Total capacity of all downstream indoor units kW <28 <45 <45 15,9 (5/8”) Connect to outdoor unit Piping connections Connect to indoor unit Liquid pipe mm (in) 12,7 (1/2”) 15,9 (5/8”) High pressureg gas pipe mm (in) 19,1 (3/4”) 22,2 (7/8”) 22,2 (7/8”) Low pressure gas pipe mm (in) 25,4 (1”) 31,8 (1 1/4”) 31,8 (1 1/4”) Liquid pipe mm (in) 9,5 (3/8”) 9,5 (3/8”) 9,5 (3/8”) Gas pipe mm (in) 15,9 (5/8”) 15,9 (5/8”) 15,9 (5/8”) Dimension (LxWxH) mm 630x225x600 960x225x600 960x225x600 Packing (LxWxH) mm 725x325x685 1.055x325x685 1.055x325x685 Net/gross weight kg 19,5/27 31/40 35/44,5 SYSVRF BOX 02-1 HR Model Art. no. 313550 Power Supply V/Ph/Hz Max number of indoor unit Max capacity of indoor unit Piping connections SYSVRF BOX 04-1 HR Connect to outdoor unit Connect to indoor unit kW 313551 220-240/1/50 1 1 20-28 40-56 15,9 (5/8”) Liquid pipe mm (in) 12,7 (1/2”) High pressure gas pipe mm (in) 19,1 (3/4”) 22,2 (5/8”) Low pressure gas pipe mm (in) 25,4 (1”) 31,8 (1 1/4”) Liquid pipe mm (in) 9,5 (3/8”) 9,5 (3/8”) Gas pipe mm (in) 15,9 (5/8”) 15,9 (5/8”) Dimension (LxWxH) mm 630x225x600 960x225x600 Packing (LxWxH) mm 725x325x685 1.055x325x685 Net/gross weight kg 19,5/27 31/40 Piping connections SYSVRF BOX Outdoor unit Indoor unit SYSVRF BOX 02 HR SYSVRF BOX 04 HR SYSVRF BOX 06 HR Liquid pipe 12,7 (1/2”) 15,9 (5/8”) 15,9 (5/8”) High pressure pipe 19,1 (3/4”) 22,2 (7/8”) 22,2 (7/8”) Low pressure pipe 25,4 (1”) 31,8 (1 1/4”) 31,8 (1 1/4”) Liquid pipe 9,5 (3/8”) 9,5 (3/8”) 9,5 (3/8”) Gas pipe 15,9 (5/8”) 15,9 (5/8”) 15,9 (5/8”) 53 54 | VRF Heat Recovery combination Outdoor unit combination SYSVRF AIR EVO HR Design Cooling/ Heating capacity kW Model Recommended combination Outdoor branch Max. indoor unit qty 25,2/27 SYSVRF 252 AIR EVO HR R SYSVRF 252 AIR EVO HR R - 13 28/31,5 SYSVRF 280 AIR EVO HR R SYSVRF 280 AIR EVO HR R - 16 33,5/37,5 SYSVRF 335 AIR EVO HR R SYSVRF 335 AIR EVO HR R - 20 40/45 SYSVRF 400 AIR EVO HR R SYSVRF 400 AIR EVO HR R - 23 45/50 SYSVRF 450 AIR EVO HR R SYSVRF 450 AIR EVO HR R - 26 53,2/58,5 SYSVRF 532 AIR EVO HR R SYSVRF 252 AIR EVO HR R + SYSVRF 280 AIR EVO HR R SYSVRF JOINT OUT 02 HR 29 56/63 SYSVRF 560 AIR EVO HR R SYSVRF 280 AIR EVO HR R x2 SYSVRF JOINT OUT 02 HR 33 61,5/69 SYSVRF 615 AIR EVO HR R SYSVRF 280 AIR EVO HR R + SYSVRF 335 AIR EVO HR R SYSVRF JOINT OUT 02 HR 36 68/76,5 SYSVRF 680 AIR EVO HR R SYSVRF 280 AIR EVO HR R + SYSVRF 400 AIR EVO HR R SYSVRF JOINT OUT 02 HR 39 73/81,5 SYSVRF 730 AIR EVO HR R SYSVRF 280 AIR EVO HR R + SYSVRF 450 AIR EVO HR R SYSVRF JOINT OUT 02 HR 43 80/90 SYSVRF 800 AIR EVO HR R SYSVRF 400 AIR EVO HR R x2 SYSVRF JOINT OUT 02 HR 46 85/95 SYSVRF 850 AIR EVO HR R SYSVRF 400 AIR EVO HR R + SYSVRF 450 AIR EVO HR R SYSVRF JOINT OUT 02 HR 50 90/100 SYSVRF 900 AIR EVO HR R SYSVRF 450 AIR EVO HR R x2 SYSVRF JOINT OUT 02 HR 53 VRF Heat Recovery combination | Design Cooling/ Heating capacity kW Model Recommended combination Outdoor branch Max. indoor unit qty 96/108 SYSVRF 960 AIR EVO HR R SYSVRF 280 AIR EVO HR R x2 + SYSVRF 400 AIR EVO HR R SYSVRF JOINT OUT 03 HR 56 101/113 SYSVRF 1010 AIR EVO HR R SYSVRF 280 AIR EVO HR R x2 + SYSVRF 450 AIR EVO HR R SYSVRF JOINT OUT 03 HR 59 106,5/119 SYSVRF 1065 AIR EVO HR R SYSVRF 280 AIR EVO HR R + SYSVRF 335 AIR EVO HR R + SYSVRF 450 AIR EVO HR R SYSVRF JOINT OUT 03 HR 63 113/126,5 SYSVRF 1130 AIR EVO HR R SYSVRF 280 AIR EVO HR R + SYSVRF 400 AIR EVO HR R + SYSVRF 450 AIR EVO HR R SYSVRF JOINT OUT 03 HR 64 120/135 SYSVRF 1200 AIR EVO HR R SYSVRF 400 AIR EVO HR R x3 SYSVRF JOINT OUT 03 HR 64 125/140 SYSVRF 1250 AIR EVO HR R SYSVRF 400 AIR EVO HR R x2 + SYSVRF 450 AIR EVO HR R SYSVRF JOINT OUT 03 HR 64 130/145 SYSVRF 1300 AIR EVO HR R SYSVRF 400 AIR EVO HR R + SYSVRF 450 AIR EVO HR R x2 SYSVRF JOINT OUT 03 HR 64 135/150 SYSVRF 1350 AIR EVO HR R SYSVRF 450 AIR EVO HR R x3 SYSVRF JOINT OUT 03 HR 64 143,2/158,5 SYSVRF 1432 AIR EVO HR R SYSVRF 252 AIR EVO HR R+ SYSVRF 280 AIR EVO HR R + SYSVRF 450 AIR EVO HR R x2 SYSVRF JOINT OUT 04 HR 64 146/163 SYSVRF 1460 AIR EVO HR R SYSVRF 280 AIR EVO HR R x2 + SYSVRF 450 AIR EVO HR R x2 SYSVRF JOINT OUT 04 HR 64 151,5/169 SYSVRF 1515 AIR EVO HR R SYSVRF 280 AIR EVO HR R + SYSVRF 335 AIR EVO HR R + SYSVRF 450 AIR EVO HR R x2 SYSVRF JOINT OUT 04 HR 64 158/176,5 SYSVRF 1580 AIR EVO HR R SYSVRF 280 AIR EVO HR R + SYSVRF 400 AIR EVO HR R + SYSVRF 450 AIR EVO HR R x2 SYSVRF JOINT OUT 04 HR 64 165/185 SYSVRF 1650 AIR EVO HR R SYSVRF 400 AIR EVO HR R x3 + SYSVRF 450 AIR EVO HR R SYSVRF JOINT OUT 04 HR 64 170/190 SYSVRF 1700 AIR EVO HR R SYSVRF 400 AIR EVO HR R x2 + SYSVRF 450 AIR EVO HR R x2 SYSVRF JOINT OUT 04 HR 64 175/195 SYSVRF 1750 AIR EVO HR R SYSVRF 400 AIR EVO HR R + SYSVRF 450 AIR EVO HR R x3 SYSVRF JOINT OUT 04 HR 64 180/200 SYSVRF 1800 AIR EVO HR R SYSVRF 450 AIR EVO HR R x4 SYSVRF JOINT OUT 04 HR 64 55 | VRF Heat Pump water-cooled Modular VRF Heat Pump Units SYSVRF WATER EVO HP Features Water-cooled VRF with DC Inverter compressor and pipe-in-pipe heat exchanger. Compact size and long piping system. High efficiency at partial load. Inverter Scroll compressor providing wide capacity output from 10% to 100% evenly. Centralized control, BMS connection and web access potential. Pipe-in-pipe heat exchanger assures excellent performance in heat trasfer and outstanding reliability. Piping connection in four different directions makes simple the installation of outdoor unit. Maximum 59 indoor units connection (100 kW modules). Indoor unit combination total capacity index from 50% to 130%. Dimensions 780 550 1000 30 620 20 112 70 64 50 52 444 52 326.5 61.5 152 95 32 45 55 176.5 52 198 56 VRF Heat Pump water-cooled | Technical features Model Indoor unit SYSVRF 252 WATER EVO HP R 280 WATER EVO HP R 335 WATER EVO HP R 314247 314248 314249 Art. no. Power Supply V/Ph/Hz 380-415/3/50 Cooling capacity kW 25,2 28,0 33,5 Power Input kW 4,80 6,10 8,00 5,25 4,59 4,19 Heating capacity kW 27,0 31,5 37,5 Power Input kW EER COP Compressor Inverter Scroll Quantity 7,80 4,81 pcs 1 W 40-80 40-80 40-80 Refrigerant oil ml 500 500 500 m3/h 5,4 6,0 7,2 kPa 35 40 48 dB(A) 51 52 52 kg 2,0 Pressure drop Sound pressure level Type R410A Refrigerant charge Dimension LxWxH mm Packing LxWxH mm Net/gross weight Piping dimension 5,83 5,40 Crankcase heater Water flow Refrigerant 4,45 6,07 2,0 2,0 780x1.000x550 845x1.170x600 kg 140/155 147/156 Liquid pipe mm (in) 9,53 (3/8”) 9,53 (3/8”) 12,7 (1/2”) Gas pipe mm (in) 22,2 (7/8”) 22,2 (7/8”) 25,4 (1”) Oil balance pipe mm (in) Water side pipe mm Max qty. indoor units connection 146/155 6,35 (1/4”) 31,8 pcs 13 16 20 Nominal conditions Indoor unit Module water inlet Piping lenght Level difference Cooling mode 27°C DB, 19°C WB 30°C DB 5m 0m Heating mode 20°C DB, 19°C WB 20°C DB 5m 0m The sound pressure value may vary depending on ambient conditions. Piping Lenght Maximum piping equivalent lenght. 100 m Maximum piping (the farthest IDU from the first indoor unit branch) equivalent lenght. Maximum outdoor unit-indoor unit drop height. 30 m Maximum indoor unit to indoor unit drop height. 20 m Modules SYSVRF WATER EVO HP Permitted value Total piping lenght (actual) Piping lenght Maximum piping 300 m Actual lenght 120 m Equivavent lenght 150 m Piping (the farthest IDU from the first indoor unit branch) equivalent lenght Drop height 8m Module indoor unit drop height Indoor unit to indoor unit drop height 40 m Module up 50 m Module down 40 m 30 m 57 58 | VRF water-cooled combination Unit combination SYSVRF WATER EVO HP Design Cooling/ Heating capacity kW Model Recommended combination Outdoor branch Max. indoor unit qty 25,2/27 SYSVRF 252 WATER EVO HP R SYSVRF 252 WATER EVO HP R - 13 28/31,5 SYSVRF 280 WATER EVO HP R SYSVRF 280 WATER EVO HP R - 16 33,5/37,5 SYSVRF 335 WATER EVO HP R SYSVRF 335 WATER EVO HP R - 20 50,4/54 SYSVRF 504 WATER EVO HP R SYSVRF 252 WATER EVO HP R x2 SYSVRF JOINT OUT 02 HP 26 53,2/58,5 SYSVRF 532 WATER EVO HP R SYSVRF 252 WATER EVO HP R + SYSVRF 280 WATER EVO HP R SYSVRF JOINT OUT 02 HP 29 56/63 SYSVRF 560 WATER EVO HP R SYSVRF 280 WATER EVO HP R x2 SYSVRF JOINT OUT 02 HP 33 61,5/69 SYSVRF 615 WATER EVO HP R SYSVRF 280 WATER EVO HP R + SYSVRF 335 WATER EVO HP R SYSVRF JOINT OUT 02 HP 36 67/75 SYSVRF 670 WATER EVO HP R SYSVRF 335 WATER EVO HP R x2 SYSVRF JOINT OUT 02 HP 39 VRF water-cooled combination | Design Cooling/ Heating capacity kW Model Recommended combination Outdoor branch Max. indoor unit qty 78,4/85,5 SYSVRF 784 WATER EVO HP R SYSVRF 232 WATER EVO HP R x2 + SYSVRF 280 WATER EVO HR R SYSVRF JOINT OUT 03 HP 43 81,2/90 SYSVRF 812 WATER EVO HP R SYSVRF 252 WATER EVO HP R + SYSVRF 280 WATER EVO HP R x2 SYSVRF JOINT OUT 03 HP 46 84/94,5 SYSVRF 840 WATER EVO HP R SYSVRF 280 WATER EVO HP R x3 SYSVRF JOINT OUT 03 HP 50 89,5/100,5 SYSVRF 895 WATER EVO HP R SYSVRF 280 WATER EVO HP R x2 + SYSVRF 335 WATER EVO HP R SYSVRF JOINT OUT 03 HP 53 95/106,5 SYSVRF 950 WATER EVO HP R SYSVRF 280 WATER EVO HP R + SYSVRF 335 WATER EVO HP R x2 SYSVRF JOINT OUT 03 HP 56 100,5/112,5 SYSVRF 1005 WATER EVO HP R SYSVRF 335 WATER EVO HP R x3 SYSVRF JOINT OUT 03 HP 59 59 | VRF Wall indoor units Wall-Mounted Indoor Units SYSVRF WALL Features Front panel of modern design that fits into any interior decor. Even and smooth air distribution due to auto swing function. Multi-refrigerant outlet pipe method: left/right/rear, more flexible for installation. Washable air filter, easy for insertion and removal. Built-in electronic expansion valve (EXV) ensuring precise flow control. Infrared receiver and remote SYSCONTROL RM 02 with address setting function as standard equipment. Wired controller SYSCONTROL WC 90 (optional) Infrared remote control SYSCONTROL RM 02 (standard) Accessories/option Wired controller SYSCONTROL WC 90 with address setting function for heat pump system. Wired controller SYSCONTROL WC 120 for heat recovery system. Wired controller SYSCONTROL WC 120 (optional) Dimensions B 60 A C Indoor unit SYSVRF WALL 15 Q WALL 22 Q WALL 28 Q WALL 36 Q WALL 45 Q WALL 56 Q A mm 915 1.072 B mm 290 315 C mm 230 230 VRF Wall indoor units | Technical features Model Indoor unit SYSVRF Art. no. Power Supply WALL 15 Q WALL 22 Q WALL 28 Q WALL 36 Q WALL 45 Q WALL 56 Q 314123 314124 314125 314126 314127 314128 V/Ph/Hz Cooling capacity kW Power Input 220-240/1/50 1,5 2,2 2,8 W Current A Heating capacity kW Power Input Current A m3/h Sound pressure level (hi/med/low) 4,5 5,6 45 0,14 1,7 0,20 2,4 3,2 W Air flow (hi/med/low) 3,6 28 4,0 0,33 5,0 6,3 28 45 0,14 0,20 525/480/430 590/520/480 860/755/830 925/860/755 35/32/29 40/38/34 Dimension (LxWxH) dB(A) mm 915x230x290 1.072x230x315 Packing (LxWxH) mm 1.020x315x390 1.180x315x415 Net/gross weight kg 13/16,5 15,1/18,8 Refrigerant Piping dimension R410A Liquid pipe mm (in) 6,4 (1/4”) 9,5 (1/4”) Gas pipe mm (in) 12,7 (1/2”) 15,9 (5/8”) Drain piping Operating ambient temp. range mm 16,5 °C Cooling +17...+32 / Heating +10...+28 Nominal conditions Indoor unit Outdoor unit Piping lenght Level difference Cooling mode 27°C DB, 19°C WB 35°C DB 8m 0m Heating mode 20°C DB, 15°C WB 7°C 8m 0m The sound pressure value may vary depending on ambient conditions. 61 | VRF Compact Cassette indoor units Compact Cassette Indoor Units SYSVRF CASSETTE MINI Features New grille SYSPANEL CASSETTE MINI VRF with 360° air discharge providing strong circulating air flow to cool or heat every corner of the room. Compact casing making it match perfectly with ambient decoration. Advanced 3D spiral fan design reducing the air resistance and operation noise. Integrated drain pump with a head of 500 mm. Fresh air hole and reserved ports for duct connection. Built-in electronic expansion valve (EXV) ensuring precise flow control. Infrared receiver and remote SYSCONTROL RM 02 with address setting function as standard equipment. Connecting points of refrigerant pipe (gas/liquid side) Drain point Wired controller SYSCONTROL WC 120 (optional) 647 (panel) Wired controller SYSCONTROL WC 90 with address setting function for heat pump system. Wired controller SYSCONTROL WC 120 for heat recovery system. 570 Accessories/option Wired controller SYSCONTROL WC 90 (optional) 523 60 Infrared remote control SYSCONTROL RM 02 (standard) 545 Dimensions 570 647 (panel) Connecting points of refrigerant pipe (gas/liquid side) Drain point 545 570 647 (panel) Hook Main body Nut Ceiling 260 647 (panel) 570 523 60 62 50 600 Panel VRF Compact Cassette indoor units | Technical features SYSVRF CASSETTE MINI 22 Q CASSETTE MINI 28 Q CASSETTE MINI 36 Q CASSETTE MINI 45 Q CASSETTE MINI 56 Q SYSPANEL CASSETTE MINI VRF CASSETTE MINI VRF CASSETTE MINI VRF CASSETTE MINI VRF CASSETTE MINI VRF Art. no. Indoor unit 314095 314096 314097 314098 314099 Art. no. Panel unit 313324 313324 313324 313324 313324 4,5 5,6 Model Indoor unit Model Panel unit Power Supply V/Ph/Hz Cooling capacity Power Input Current 2,2 2,8 W 48 48 kW Power Input W Current A Air flow (hi/med/low) Sound pressure level (hi/med/low) Panel kW A Heating capacity Unit 220-240/1/50 3,6 56 0,175 2,4 0,21 3,2 4,0 0,175 0,21 m3/h 522/414/313 610/521/409 dB(A) 35,8/33,4/23,4 Dimension (LxWxH) mm Packing (LxWxH) mm Net/gross weight kg 6,0 56 41,5/35,6/28,8 570x570x260 675x675x285 17,5/22 19/23,5 Dimension (LxWxH) mm 647x675x50 Packing (LxWxH) mm 705x705x113 Net/gross weight kg 3/5 Refrigerant Piping dimension 5,0 48 R410A Liquid pipe mm (in) 6,4 (1/4”) 9,5 (3,8”) Gas pipe mm (in) 12,7 (1/2”) 15,9 (5/8”) Drain piping Operating ambient temp. range mm 25 °C Cooling +17...+32 / Heating +10...+28 Nominal conditions Indoor unit Outdoor unit Piping lenght Level difference Cooling mode 27°C DB, 19°C WB 35°C DB 8m 0m Heating mode 20°C DB, 15°C WB 7°C 8m 0m The sound pressure value may vary depending on ambient conditions. 63 | VRF Cassette indoor units Standard Cassette Indoor Units SYSVRF CASSETTE Features Wired controller SYSCONTROL WC 90 (optional) Infrared remote control SYSCONTROL RM 02 (standard) Accessories/option Wired controller SYSCONTROL WC 90 with address setting function for heat pump system. Wired controller SYSCONTROL WC 120 for heat recovery system. Wired controller SYSCONTROL WC 120 (optional) 950 780 105 Φ ou A 950 680 55 840 New grille SYSPANEL CASSETTE EVO with 360° air discharge providing strong circulating air flow to cool or heat every corner of the room. Ultra-thin casing for easy installation into a shallow ceiling. Advanced 3D spiral fan design reducing the air resistance and operation noise. Models 90, 112 and 140 equipped with high efficient DC fan motor. Integrated drain pump with a head of 750 mm. Fresh air hole and reserved ports for duct connection. Built-in electronic expansion valve (EXV) ensuring precise flow control. Infrared receiver and remote SYSCONTROL RM 02 with address setting function as standard equipment. Dimensions 950 780 105 Φ32 Drain pipe outter diameter A B 70 Φ75 New air supply orifice ≥20 146 840 55 950 680 Ceiling B CASSETTE 28 Q Indoor unit SYSVRF 840 904 Φ75 New air supply orifice CASSETTE ≥20 36 Q CASSETTE 45 Q CASSETTE 56 Q CASSETTE 71 Q 46 Panel Main body CASSETTE 90 Q CASSETTE 112 Q A mm 230 230 300 B mm 170 170 190 Ceiling Panel Main body 146 64 46 CASSETTE 140 Q VRF Cassette indoor units | Technical features Model Indoor unit Model Panel unit SYSVRF CASSETTE CASSETTE CASSETTE CASSETTE CASSETTE CASSETTE CASSETTE CASSETTE 28 Q 36 Q 45 Q 56 Q 71 Q 90 Q 112 Q 140 Q SYSPANEL CASSETTE CASSETTE CASSETTE CASSETTE CASSETTE CASSETTE CASSETTE CASSETTE EVO VRF EVO VRF EVO VRF EVO VRF EVO VRF EVO VRF EVO VRF EVO VRF Art. no. Indoor unit 314100 314101 313325 314102 314103 314255 314256 314257 Art. no. Panel unit 313728 313728 313728 313728 313728 313728 313728 313728 14,0 Power Supply V/Ph/Hz Cooling capacity kW Power Input W Current A Heating capacity kW Power Input W Current A m3/h Air flow (hi/med/low) Sound pressure level (hi/med/low) Unit Panel 220-240/1/50 2,8 3,6 80 mm Packing (LxWxH) mm Net/gross weight kg 5,6 7,1 9,0 11,2 90 75 82 125 125 0,40 3,2 4,0 80 0,50 847/766/640 6,3 8,0 10,0 12,5 75 82 125 125 42/38/35 135 0,70 0,80 1.157/ 955/749 1.540/1.300/1.120 1.800/ 1.500/ 1.280 45/42/39 47/41/36 50/45/35 840x840x300 955x955x247 24/28 15,0 0,50 840x840x230 955x955x317 26/30 32/37 Dimension (LxWxH) mm 950x950x46 Packing (LxWxH) mm 1.000x1.000x60 Net/gross weight kg 6/8 Refrigerant Piping dimension 0,80 90 864/755/658 135 0,70 5,0 0,40 dB(A) Dimension (LxWxH) 4,5 R410A Liquid pipe mm (in) 6,4 (1/4”) 9,5 (3/8”) Gas pipe mm (in) 12,7 (1/2”) 15,9 (5/8”) Drain piping Operating ambient temp. range mm 32 °C Cooling +17...+32 / Heating +10...+28 Nominal conditions Indoor unit Outdoor unit Piping lenght Level difference Cooling mode 27°C DB, 19°C WB 35°C DB 8m 0m Heating mode 20°C DB, 15°C WB 7°C 8m 0m The sound pressure value may vary depending on ambient conditions. 65 66 | VRF Cassette 1way indoor units Cassette 1Way Indoor Unit SYSVRF CASSETTE 1W Features Stylish look with new decorative panel. Ultra-thin chassis for easy installation in false ceiling. Integrated drain pump with a head of 750mm. Built-in electronic expansion valve (EXV) ensuring precise flow control. Infrared receiver and remote controller SYSCONTROL RM 02. With address setting function as standard equipment. Accessories/option Wired controller SYSCONTROL WC 90 with address setting function for heat pump system. Wired controller SYSCONTROL WC 120 for heat recovery system. Infrared remote control SYSCONTROL RM 02 (standard) Wired controller SYSCONTROL WC 120 (optional) Dimensions 1015 Wired controller SYSCONTROL WC 90 (optional) 290 VRF Cassette 1way indoor units | Technical features Model Indoor unit SYSVRF Model Panel unit SYSPANEL Art. no. Indoor unit CASSETTE 1W 18 Q CASSETTE 1W 22 Q CASSETTE 1W 28 Q CASSETTE 1W 36 Q CASSETTE 1W VRF CASSETTE 1W VRF CASSETTE 1W VRF CASSETTE 1W VRF 314213 314214 314215 314216 2,8 3,6 Art. no. Panel unit 314217 Power Supply V/Ph/Hz Cooling capacity kW Power Input Current 41 A kW Power Input 0,24 0,25 2,2 2,6 3,2 W Current A m3/h Air flow (hi/med/low) Sound pressure level (hi/med/low) Panel 2,2 W Heating capacity Unit 220-240/1/50 1,8 dB(A) 0,24 0,25 523/404/275 573/456/315 39/37/34 40/38/34 Dimension (LxWxH) mm 1.054×425×169 1.054×425×169 Packing (LxWxH) mm 1.155×490×245 1.155×490×245 Net/gross weight kg 12,5/16 13/16,5 Dimension (LxWxH) mm 1.180×465×36.5 1.180×465×36.5 Packing (LxWxH) mm 1.232×517×107 1.232×517×107 Net/gross weight kg 3,5/5,2 9/12 Refrigerant Piping dimension 4,0 41 R410A Liquid pipe mm (in) 6,4 (1/4”) Gas pipe mm (in) 12,7 (1/2”) Drain piping Operating ambient temp. range mm 25 °C Cooling +17...+32 / Heating +10...+28 Nominal conditions Indoor unit Outdoor unit Piping lenght Level difference Cooling mode 27°C DB, 19°C WB 35°C DB 8m 0m Heating mode 20°C DB, 15°C WB 7°C 8m 0m The sound pressure value may vary depending on ambient conditions. 67 | VRF Cassette 2way indoor units Cassette 2Way Indoor Unit SYSVRF CASSETTE 2W Features Stylish look with new decorative panel. Slim casing for easy installation in narrow ceiling. Integrated drain pump with a head of 750mm. Built-in electronic expansion valve (EXV) ensuring precise flow control. Infrared receiver and remote controller SYSCONTROL RM 02. With address setting function as standard equipment. Wired controller SYSCONTROL WC 90 (optional) Infrared remote control SYSCONTROL RM 02 (standard) Accessories/option Wired controller SYSCONTROL WC 90 with address setting function for heat pump system. Wired controller SYSCONTROL WC 120 for heat recovery system. Wired controller SYSCONTROL WC 120 (optional) Dimensions 591 436 129 129 701 1430 44 104 91 171 91 299 176 192 120 42~45 Φ 32 51 44 45 151 Φ160 299 117 Φ 32 257 241 185 1172 57 Fresh air connector Φ 12 5 680 The panel contour dimension 1430 20 20 Machine body size 1172 701 129 44 151 Hanging screw bolts distance 520 20 Machine body size 591 The ceiling opening dimension 640 20 The ceiling opening dimension 1390 Hanging screw bolts distance 1207 The ceiling opening (1390*640) The panel contour dimension 680 68 VRF Cassette 2way indoor units | Technical features Model Indoor unit Model Panel unit SYSVRF CASSETTE 2W 22 Q CASSETTE 2W 28 Q CASSETTE 2W 36 Q CASSETTE 2W 45 Q CASSETTE 2W 56 Q SYSPANEL CASSETTE 2W VRF CASSETTE 2W VRF CASSETTE 2W VRF CASSETTE 2W VRF CASSETTE 2W VRF 314218 314219 314220 314221 314222 Art. no. Indoor unit Art. no. Panel unit 314224 Power Supply V/Ph/Hz Cooling capacity kW Power Input Current 41 A Power Input Current 0,35 7,1 92 108 0,45 0,55 3,2 4,0 5,0 6,3 W 57 60 92 108 154 dB(A) Dimension (LxWxH) mm Packing (LxWxH) mm Net/gross weight kg 0,35 0,45 654/530/410 725/591/458 33/29/24 0,55 850/670/550 36/32/29 980/800/670 39/35/30 1.172×425×169 1.355×675×400 34/42,5 36/44,5 Dimension (LxWxH) mm 1.430x680x299 Packing (LxWxH) mm 1.525x765x130 Net/gross weight kg 10,5/15 Refrigerant Piping dimension 5,6 60 2,6 A Sound pressure level (hi/med/low) 4,5 kW m3/h Air flow (hi/med/low) Panel 3,6 W Heating capacity Unit 220-240/1/50 2,2 R410A Liquid pipe mm (in) 6,4 (1/4”) 9,5 (3/8”) Gas pipe mm (in) 12,7 (1/2”) 15,9 (5/8”) Drain piping Operating ambient temp. range mm 32 °C Cooling +17...+32 / Heating +10...+28 Nominal conditions Indoor unit Outdoor unit Piping lenght Level difference Cooling mode 27°C DB, 19°C WB 35°C DB 8m 0m Heating mode 20°C DB, 15°C WB 7°C 8m 0m The sound pressure value may vary depending on ambient conditions. 69 | VRF Ceiling/Floor indoor units Ceiling and Floor Indoor Units SYSVRF CEILING Features 995 906,5 371 Infrared remote 198,2 control SYSCONTROL RM 02 (standard) 35 39,5 98 133,5 175 401 655 200 207 Flexible vertical or horizontal installation, even into a corner of the ceiling. Even and smooth air distribution due to auto horizontal and auto vertical swing function. Models 90,112 and 140 equipped with high efficient DC fan motor. Wide angle air flow. Low noise operation. Washable air filter, easy for insertion and removal. Built-in electronic expansion valve (EXV) ensuring precise flow control. Infrared receiver and remote SYSCONTROL RM 02 with address setting function as standard equipment. Wired controller SYSCONTROL WC 90 (optional) Wired controller SYSCONTROL WC198,2 120 (optional) 1284,5 1194,5 547 515 39,5 37 Wired controller SYSCONTROL WC 120 for heat recovery system. 655 Wired controller SYSCONTROL WC 90 with address setting function for heat pump system. 200 98 133,5 175 Accessories/option Dimensions SYSVRF CEILING 36/45/56/71 Q 995 SYSVRF CEILING 112/140 Q 906,5 35 39,5 198,2 198,2 198,2 39,5 37 1670 1542,3 724,5 630,5 198,2 655 200 98 133,5 175 200 39,5 37 655 515 98 133,5 175 547 515 235 112,5 144 184,5 255,2 655 1284,5 1194,5 1284,5 1194,5 630,5 675 200 SYSVRF CEILING 90 Q 547 1670 1542,3 724,5 69,5 655 371 35 39,5 98 133,5 175 200 401 371 207 906,5 98 133,5 175 995 401 207 70 VRF Ceiling/Floor indoor units | Technical features Model Indoor unit SYSVRF Art. no. Power Supply CEILING 36 Q CEILING 45 Q CEILING 56 Q 314116 314117 314118 V/Ph/Hz Cooling capacity Power Input Current CEILING 71 Q CEILING 90 Q CEILING 112 Q CEILING 140 Q 314119 314282 314283 314284 11,2 220-240/1/50 kW 3,6 4,5 5,6 7,1 9,0 W 49 120 122 125 126 A 0,57 0,60 kW 4,0 5,0 6,3 8,0 10,0 Power Input W 49 120 122 125 126 65x2 Current A 0,57 0,60 0,83 Heating capacity Air flow (hi/med/low) Sound pressure level (hi/med/low) 0,55 14,0 65x2 0,55 0,83 12,5 15,5 m3/h 650/ 570/500 800/600/500 1.200/ 900/700 1.980/1.860/1.730 dB(A) 40/38/36 43/41/38 45/43/40 47/45/42 1.670x244x680 Dimension (LxWxH) mm 990x206x660 1.280x 206x660 Packing (LxWxH) mm 1.089x296x744 1.379x 296x744 1.764x329x760 Net/gross weight kg 34,5/41 54/59 26/32 28/34 Refrigerant Piping dimension R410A Liquid pipe mm (in) 6,4 (1/4”) 9,5 (3/8”) Gas pipe mm (in) 12,7 (1/2”) 15,9 (5/8”) Drain piping Operating ambient temp. range mm 16 °C Cooling +17...+32 / Heating +10...+28 Nominal conditions Indoor unit Outdoor unit Piping lenght Level difference Cooling mode 27°C DB, 19°C WB 35°C DB 8m 0m Heating mode 20°C DB, 15°C WB 7°C 8m 0m The sound pressure value may vary depending on ambient conditions. 71 | VRF Duct indoor units Medium Static Pressure Duct Indoor Units SYSVRF DUCT Features External static pressure up to 100 Pa. Models 90, 112 and 140 equipped with high efficient DC fan motor. Washable air filter placed in an aluminum frame which is removable downward from the bottom. Fresh air hole, air inlet/outlet flange are standard for easy duct connection. Air inlet from back as standard and from bottom as optional with the same flange plate. Integrated drain pump with a head of 750 mm. Electronic expansion valve (EXV) fixed inside of the indoor unit. Std functional port such as remote on/off free contact. Display board with infrared receiver as standard equipment. Wired controller SYSCONTROL WC 90 with address setting function as standard equipment. Wired controller SYSCONTROL WC 90 (standard) Infrared remote control SYSCONTROL RM 02 (optional) Wired controller SYSCONTROL WC 120 (optional) Accessories/option Infrared controller SYSCONTROL RM 02 with address setting function for heat pump system. Wired controller SYSCONTROL WC 120 for heat recovery system. Dimensions Indoor unit SYSVRF DUCT 22 Q DUCT 28 Q DUCT 36 Q DUCT 45 Q DUCT 56 Q mm 700 700 700 920 920 mm 210 210 210 210 210 C mm 635 635 635 635 635 D mm 570 570 570 570 570 B H A B I 72 F G A E E mm 65 65 65 65 65 F mm 493 493 493 713 713 G mm 35 35 35 35 35 H mm 119 119 119 119 119 A mm DUCT 71 Q 920 B mm 270 270 270 300 C mm 635 775 775 865 D mm 570 710 710 800 E mm 65 65 65 80 F mm 713 933 933 993 G mm 35 35 35 40 H mm 179 179 179 204 Indoor unit SYSVRF D C DUCT 90 Q 1.140 DUCT 112 Q 1.140 DUCT 140 Q 1.200 VRF Duct indoor units | Technical features Model Indoor unit DUCT 22 Q DUCT 28 Q DUCT 36 Q DUCT 45 Q 314107 314108 314109 314110 SYSVRF Art. no. Power Supply V/Ph/Hz Cooling capacity kW 2,2 2,8 3,6 W 59 57 61 Current A kW 2,6 3,2 4,0 W 59 57 61 Current A m3/h Sound pressure level (hi/med/low) dB(A) External static pressure DUCT 90 Q DUCT 112 Q DUCT 140 Q 314111 314112 314261 314262 314258 14,0 4,5 0,28 Power Input Air flow (hi/med/low) DUCT 71 Q 220-240/1/50 Power Input Heating capacity DUCT 56 Q 7,1 9,0 11,2 92 5,6 149 68 200 160 0,50 0,70 1,00 1,80 1,55 15,5 5,0 8,0 10,0 12,5 92 149 68 200 160 0,28 0,50 0,70 1,00 1,80 1,55 570/410/320 958/667/583 1207/ 905/821 1290/ 1090/ 940 1790/ 1550/ 1352 1950/ 1600/ 1400 43/38,9/36 45/ 40/36 44/ 38/37 47/ 41/37 42/ 47/38 20 (10~50) 40 40 (10~80) (10~100) 42/ 38/36 40/35/32 6,3 10 (10~30) Pa Dimension (LxWxH) mm 700х635х210 920х635х210 920х 635х270 1.140х775х270 1.200х 865х300 Packing (LxWxH) mm 915х655х290 1.135х655х290 1.135х 655х350 1.355х795х350 1.385х 920х375 Net/gross weight kg 27/32 30/34 40/48 49/58 21,5/26 22/27 Refrigerant R410A Piping dimension Liquid pipe mm (in) 6,4 (1/4”) 9,5 (1/4”) Gas pipe mm (in) 12,7 (1/2”) 15,9 (5/8”) Drain piping mm Operating ambient temp. range 32 °C Cooling +17…+32 / Heating +10…+28 Fan performance 30 30 20 20 10 50 40 40 30 30 30 20 30 20 20 10 10 Low speed Low speed Low Low speed speed Low Low speed speed 20 10 10 50 50 40 40 30 30 20 20 10 10 50 40 40 30 30 20 20 10 10 400200 600 400 800 600 800 200 400 600 800 280 280 280 3 3 Air 200 flow (m 3400 Air /h) flow (m flow /h) /h) 200 Air 600 200 400(m 800 400 600 600 800 800 280 280 280 3 3 3 Air flow (m /h) Air flowAir (mflow /h) (m /h) 10 420 600 50 40 30 30 20 20 10 1000 1200 1200 30 20 20 10 10 800630 800 1000 1400 1000 1200 1000 1200 630 180 160 180 180 160 160 180 160 180 180 160 160 80Super high 160 140 160 160 140 140 160 140 160 160 140 140 30 20 10 60 50 40 30 20 60 50 40 30 20 10 10 70 60 50 40 30 20 10 770800 70 60 50 40 30 20 10 Super highSuper high speed speed speed Super high Super high Super high 70 speed speed speed 60 50 40 30 High speed High speed Medium speed Medium Low speed speed Low speed High High speed speed High High speed speed Medium Medium speed speed Medium Medium Low Low speed speed speed speed Low Low speed speed 20 10 1000 800 770 1200 800 1000 1400 1000 1200 770 140 120 120 100 100 80 60 40 20 80 60 40 20 1200 1400 1400 3 Air /h) flow Air (m 31400 flow /h) (m 3/h) 1000 800 1200 800 1000 1000 1200 1200 1400 1400 770800Air flow 770(m 770 3 Air flow (m 3/h) Air flowAir (mflow /h) (m 3/h) 140 140 120 120 120 120 100 100 100 100 80 80 60 40 20 80 60 40 20 60 40 20 80 60 Super high Super highSuper high speed speed speed Super high Super high Super high High High High speed speed speed speed speed speed High High High speed speed speed Medium speed Medium Low speed speed Low speed External static pressure (Pa) External static pressure (Pa) 40 70 80 External static pressure (Pa) External static pressure (Pa) 50 70 External static pressure (Pa) 60 80 External static pressure (Pa) 70 80 Medium Medium speed speed Medium Medium Low speed Low speed speed speed Low Low speed speed 40 140 120 120 100 100 80 60 40 20 20 80 60 40 20 1000 1400 1000 1000 1400 1800 1400 2200 1800 1800 2200 2200 1020 1020 1020 3 (m 3Air /h)1000 flow1800 Air (m 3flow /h)1400 (m2200 /h) 1000Air flow1400 1000 1400 1800 18002200 2200 1020 1020 1020 3 3 3 Air flow (m /h) Air flowAir (mflow /h) (m /h) External static pressure (Pa) External static pressure (Pa) 200 200 180 180 90 90 External static pressure (Pa) 220 220 200 200 200 180 External static pressure (Pa) 220 200 200 200 180 180 External static pressure (Pa) External static pressure (Pa) 220 220 200 200 200 180 External static pressure (Pa) 220 200 100 100 90 90 External static pressure (Pa) 110 110 100 100 100 90 External static pressure (Pa) External static pressure (Pa) 110 100 80 3 3 SYSVRF DUCT 140 Q 220 220 220 110 90 1400 Air flow (m /h) Air flowAir (mflow /h) (m /h) 3 110 80 1200 1400 3 3 Air 800 flow (m 3630 Air /h) flow Air (m flow /h) (m /h) 1000 800 1200 800 1000 1400 1000 1200 1200 1400 1400 630 630 3 SYSVRF DUCT 112 Q 220 220 220 40 30 10 Air flow (m /h) Air flowAir (mflow /h) (m /h) SYSVRF DUCT 90 Q 110 3 Super highSuper high speed speed speed 50 Super high Super high Super high speed speed speed 40 High High High speed speed 40 speed High High High speed speed speed 30 Medium Medium Medium speed speed speed 30 Medium Medium Medium speed speed speed 20 Low Low Low speed speed speed 20 Low Low Low speed speed speed 10 50 630 800 3 3 Air 600 flow (m 3420 Air /h) flow Air (m flow /h) /h) 800 600 1000 600 800(m 1200 800 1000 1000 1200 1200 420 420 3 50Super high 40 10 800600420 1000 600 800 800 1200 1000 420 60 50 40 10 60 60 50 Super highSuper high speed speed speed 50 Super high Super high Super high speed speed speed 40 High High High speed speed 40 speed High High High speed speed speed 30 Medium Medium Medium speed speed speed 30 Medium Medium Medium speed speed speed 20 Low Low Low speed speed speed 20 Low Low Low speed speed speed 10 70 60 60 50Super high 50 80 70 70 60 60 80 80 70 70 70 60 80 80 70 60 60 60 200 External static pressure (Pa) External static pressure (Pa) 70 60 80 80 70 External static pressure (Pa) External static pressure (Pa) 40 External static pressure (Pa) External static pressure (Pa) External static pressure (Pa) 50 External static pressure (Pa) External static pressure (Pa) External static pressure (Pa) 50 Super high Super highSuper high speed speed speed Super high Super high Super high High High speed speed High speed 50 speed speed speed High High High 50 speed speed speed Medium Medium Medium 40 speed speed speed Medium Medium Medium 40 speed speed speed 60 External static pressure (Pa) External static pressure (Pa) 60 50 70 60 60 80 70 External static pressure (Pa) 60 70 SYSVRF DUCT 71 Q 80 External static pressure (Pa) 70 60 80 70 70 70 40 80 80 External static pressure (Pa) External static pressure (Pa) 80 70 80 External static pressure (Pa) 80 70 SYSVRF DUCT 45/56 Q 80 External static pressure (Pa) 80 External static pressure (Pa) External static pressure (Pa) SYSVRF DUCT 22/28/36 Q 80 140 140 120 120 120 120 100 100 Super high Super highSuper high speed speed speed Super high Super high Super high High High High speed speed speed speed speed speed High High High speed speed speed Medium speed Medium Low speed speed Low speed 100 100 80 80 60 40 20 80 60 40 20 60 40 20 80 60 Medium Medium speed speed Medium Medium Low speed Low speed speed speed Low Low speed speed 40 20 1000 1400 1800 1400 2200 1800 1800 2200 2200 10601000 10601400 10601000 3 3 3 Air flow (m Air /h) flow Air (m flow /h) (m /h) 1400 1000 1000 1800 1400 1400 2200 1800 18002200 2200 10601000 1060 1060 3 Air flow (m 3/h) Air flowAir (mflow /h) (m 3/h) Nominal conditions Indoor unit Outdoor unit Piping lenght Level difference Cooling mode 27°C DB, 19°C WB 35°C DB 8m 0m Heating mode 20°C DB, 15°C WB 7°C 8m 0m The sound pressure value may vary depending on ambient conditions. 73 | VRF Duct HP indoor units High Static Pressure Duct Indoor Units SYSVRF DUCT HP Features External static pressure up to 250 Pa. Washable air filter placed in an aluminum frame which is removable downward from the bottom. Easy access both in rear and bottom. Fresh air hole, air inlet/outlet flange are standard for easy duct connection. Electronic expansion valve (EXV) fixed inside of the indoor unit. Display board with infrared receiver as standard equipment. Wired controller SYSCONTROL WC 90 with address setting function as standard equipment. Wired controller SYSCONTROL WC 90 (standard) Accessories/option Infrared remote control SYSCONTROL RM 02 (optional) Wired controller SYSCONTROL WC 120 (optional) Infrared remote SYSCONTROL RM 02 with address setting function for heat pump system. Wired controller SYSCONTROL WC 120 for heat recovery system. Dimensions 135 60 96 930 88 82 343 29 86 82 270 420 249 Plastic cover Plastic cover Electrical control box SYSVRF DUCT HP 200/280 Q 936 75 Electrical control box 200 378 343 60 96 1121 24 46 68 50 952 856 85 214 75 1121 SYSVRF DUCT HP 140 Q 56 SYSVRF DUCT HP 71/112 Q 420 74 VRF Duct HP indoor units | Technical features Model Indoor unit SYSVRF Art. no. Power Supply DUCT HP 71 Q DUCT HP 112 Q DUCT HP 140 Q DUCT HP 200 Q DUCT HP 280 Q 314129 314130 314131 314132 314133 V/Ph/Hz Cooling capacity 220-240/1/50 kW 7,1 11,2 14,0 20,0 28,0 W 263 524 724 1.516 1.516 Power Input Current A 1,1 2,3 2,7 6,6 6,6 kW 8,0 12,5 16,0 22,5 31,5 Power Input W 263 524 724 1.516 1.516 Current A 1,1 2,3 2,7 6,6 6,6 1.510/ 1.399/1.236 2.117/ 1.950/1.644 2.988/ 2.670/2.229 4.268/ 3.780/3.200 4.400/ 3.700/3.200 Heating capacity m /h Air flow (hi/med/low) 3 Sound pressure level (hi/med/low) External static pressure dB(A) Pa 48/46/44 52/49/47 53/50/48 59/55/52 59/55/52 40 (30~196) 50 (30~196) 50 (30~196) 140 (50~250) 160 (50~250) Dimension (LxWxH) mm 856x690x420 856x690x420 1.200x600x400 1.356x763x470 1.356x763x470 Packing (LxWxH) mm 1.090x768x440 1.090x768x440 1.436x768x450 1.509x964x570 1.509x964x570 Net/gross weight kg 45/50 50,6/56 68/70 115/129 115/129 Refrigerant R410A Piping dimension Liquid pipe mm (in) 9,5 (3/8”) 9,5 (3/8”) 9,5 (3/8”) 9,5 (3/8”) (x2) 9,5 (3/8”) (x2) Gas pipe mm (in) 15,9 (5/8”) 15,9 (5/8”) 15,9 (5/8”) 15,9 (5/8”) (x2) 15,9 (5/8”) (x2) 32 32 32 32 32 Drain piping mm Operating ambient temp. range °C Cooling +17…+32 / Heating +10…+28 Fan performance SYSVRF DUCT HP 112 Q P(Pa) P(Pa) SYSVRF DUCT HP 71 Q 300 300 280 280 260 260 240 240 220 220 200 200 180 180 140 120 100 80 60 High speed 160 High speed 140 120 Midium speed Midium speed 100 80 Low speed Low speed 60 40 40 20 20 0 800 1000 1200 1400 1600 1800 2000 0 Q(m3/h) SYSVRF DUCT HP 280 Q P(Pa) SYSVRF DUCT HP 200 Q 300 300 280 280 260 260 240 240 220 220 200 200 180 180 160 160 High speed 800 1000 1200 1400 1600 1800 2000 2200 Q(m3/h) P(Pa) SYSVRF DUCT HP 140 Q 400 600 P(Pa) 160 300 280 260 High speed 200 Midium speed 120 120 100 100 80 80 60 60 40 40 40 20 20 100 Midium speed 80 Low speed 60 0 0 400 600 800 1000 1200 1400 1600 1800 2000 Q(m3/h) Low speed 160 140 120 Midium speed 180 Low speed 140 140 High speed 240 220 20 0 2000 2500 3000 3500 4000 4500 5000 5500 6000 2000 2500 3000 3500 4000 4500 5000 5500 6000 Q(m3/h) Q(m3/h) Nominal conditions Indoor unit Outdoor unit Piping lenght Level difference Cooling mode 27°C DB, 19°C WB 35°C DB 8m 0m Heating mode 20°C DB, 15°C WB 7°C DB 8m 0m The sound pressure value may vary depending on ambient conditions. 75 | Exposed floor indoor unit Exposed floor indoor unit SYSVRF FLOOR EB Features With 22cm of depth and 63cm of height, the unit perfectly fits any interior design. Models 71 and 80 are equipped with high efficient DC fan motor. Washable air filter included. Built-in electronic expansion valve (EXV) ensuring precise flow control. Infrared receiver and remote controller SYSCONTROL RM 02 with address setting function as standard equipment. Wired controller SYSCONTROL WC 90 (optional) Infrared remote control SYSCONTROL RM 02 (standard) Accessories/option Wired controller SYSCONTROL WC 90 with address setting function for heat pump system. Wired controller SYSCONTROL WC 120 for heat recovery system. Wired controller SYSCONTROL WC 120 (optional) Dimensions Mounting hole, 4 A B I 4xФ11 4xФ18 EXV G D Gas side connector Liquid side connector H F E C 76 J Indoor unit SYSVRF FLOOR EB 22 Q FLOOR EB 28 Q Air inlet grille FLOOR EB 36 Q FLOOR EB 45 Q A mm 1.000 1.200 B mm 725 925 C mm D mm E mm 284 F mm 232 G mm H mm I mm 220 J mm 150 FLOOR EB 56 Q FLOOR EB 71 Q 1.500 1.225 672 592 310 258 345 94 100 100 FLOOR EB 80 Q Exposed floor indoor unit | Technical features Model Indoor unit SYSVRF Art. no. Power Supply FLOOR EB 22 Q FLOOR EB 28 Q FLOOR EB 30 Q 314225 314226 314227 V/Ph/Hz Cooling capacity Power Input Current FLOOR EB 45 Q FLOOR EB 56 Q FLOOR EB 71 Q FLOOR EB 80 Q 314228 314229 314285 314286 4,5 5,6 7,1 49 88 220-240/50/1 kW 2,2 W 40 2,8 3,6 46 8,0 130 A 0,18 0,21 0,22 0,22 0,4 0,56 kW 2,6 3,2 4,0 5,0 6,3 8,0 Power Input W 40 49 88 Current A Heating capacity m3/h Air flow (hi/med/low) Sound pressure level (hi/med/low) External static pressure dB(A) 46 0,18 0,21 0,22 0,22 0,4 569/ 485/421 624/ 522/375 660/ 542/440 1.150/ 970/830 1.380/1.100/870 36/33/29 37/34/30 37/34/30 41/35/31 44/39/33 1.200× 625×220 0,56 0,59 1.500× 625×220 1.500×625×220 1.682×683×312 12 Pa Dimension (LxWxH) mm 1.000×625×220 Packing (LxWxH) mm 1.182×683×312 1.382× 683×312 1.382× 683×312 1.682× 683×312 Net/gross weight kg 30/38 35,5/41 35,5/41 42/51 Refrigerant Drain piping 9,0 130 530/ 456/400 1.200× 625×220 Piping dimension 0,59 42/51 44/53 R410A Liquid pipe mm (in) 6,35 6,35 9,53 9,53 Gas pipe mm (in) 12,7 12,7 15,9 16 mm 16 Nominal conditions Indoor unit Outdoor unit Piping lenght Level difference Cooling mode 27°C DB, 19°C WB 35°C DB 8m 0m Heating mode 20°C DB, 15°C WB 7°C DB 8m 0m The sound pressure value may vary depending on ambient conditions. 77 | Concealed floor indoor unit Concealed floor indoor unit SYSVRF FLOOR CB Features With only 21cm thick, the unit can be easily hidden in narrow space. Models 71 and 80 are equipped with high efficient DC fan motor. Washable air filter included. Built-in electronic expansion valve (EXV) ensuring precise flow control. Infrared receiver and remote controller SYSCONTROL RM 02 with address setting function as standard equipment. Wired controller SYSCONTROL WC 90 (optional) Infrared remote control SYSCONTROL RM 02 (standard) Accessories/option Wired controller SYSCONTROL WC 90 with address setting function for heat pump system. Wired controller SYSCONTROL WC 120 for heat recovery system. Wired controller SYSCONTROL WC 120 (optional) Dimensions Connecting point of refrigerant pipe (Liquid side ΦA) 544 345 Connecting point of refrigerant pipe (Gas side ΦB) 177 78 212 C A B C FLOOR CB 22 MODEL mm 6,4 12,7 725 FLOOR CB 28 mm 6,4 12,7 725 FLOOR CB 36 mm 6,4 12,7 925 FLOOR CB 45 mm 6,4 12,7 925 FLOOR CB 56 mm 9,5 15,9 1.225 Concealed floor indoor unit | Technical features Model Indoor unit SYSVRF Art. no. Power Supply FLOOR CB 22 Q FLOOR CB 28 Q FLOOR CB 36 Q 314232 314233 314234 V/Ph/Hz Cooling capacity Power Input Current FLOOR CB 45 Q FLOOR CB 56 Q FLOOR CB 71 Q FLOOR CB 80 Q 314235 314236 314287 314288 4,5 5,6 7,1 49 88 220-240/50/1 kW 2,2 W 40 2,8 3,6 46 8,0 130 A 0,18 0,21 0,22 0,22 0,4 0,56 kW 2,6 3,2 4,0 5,0 6,3 8,0 Power Input W 40 49 88 Current A Heating capacity m3/h Air flow (hi/med/low) Sound pressure level (hi/med/low) External static pressure dB(A) 46 0,18 0,21 0,22 0,22 0,4 569/ 485/421 624/ 522/375 660/ 542/440 1.150/ 970/830 1.380/1.100/870 36/33/29 37/34/30 37/34/30 41/35/31 44/39/33 1.036× 544×212 0,56 0,59 1.336× 544×212 1.336×544×212 1.425×639×305 12 Pa Dimension (LxWxH) mm 840×544×212 Packing (LxWxH) mm 939×639×305 1.139× 639×305 1.139× 639×305 1.425× 639×305 Net/gross weight kg 25/27 29,5/34 29,5/34 33/39 Refrigerant Drain piping 9,0 130 530/ 456/400 1.036× 544×212 Piping dimension 0,59 33/39 36/40 R410A Liquid pipe mm (in) 6,35 6,35 9,53 9,53 Gas pipe mm (in) 12,7 12,7 15,9 16 mm 16 Nominal conditions Indoor unit Outdoor unit Piping lenght Level difference Cooling mode 27°C DB, 19°C WB 35°C DB 8m 0m Heating mode 20°C DB, 15°C WB 7°C DB 8m 0m The sound pressure value may vary depending on ambient conditions. 79 | VRF Heat Recovery Ventilation Heat Recovery Ventilation Units SYSVRF HRV Features Cross flow heat exchanger made of special paper for enhanced heat exchange efficiency. Main structure made of galvanized steel sheet. High efficient DC fan motor assures low power consumption. 3 fan speeds available for sizes 500 m3/h and 1000 m3/h, 1 speed for size 2000 m3/h. Temperature exchange efficiency above 65%. Compact design and flexible installation in the false ceiling. Different operating modes available: heat exchange, bypass, auto, exhaust/supply mode (bypass damper not included in the HRV 2000 R). Insulation material guarantees quiet operation and thermal insulation. Thanks to the flexible control the HRV unit can be interlocked to the operation of the VRF indoor units. Wired controller SYSCONTROL WC 27 as standard equipment. SYSVRF HRV 500/1000 Q SYSVRF HRV 2000 R Wired controller SYSCONTROL WC 27 (standard) Dimensions SYSVRF HRV 500/1000 Q SYSVRF HRV 2000 R W L 75 1550 H W2 C Air exhaust vent By-pass Air return system vent Flange demension W1 1400 L1 G Model SYSVRF HRV 500 Q SYSVRF HRV 1000 Q L 824 1.116 L1 754 1.045 W 904 1.134 W1 960 1.190 500 678 H 270 388 C 107 85 G 19 19 N Φ194 Φ242 N2 111 170 350 Air supply vent 540 700 250 120 320 1600 346 Air supply vent Air exhaust vent 370 1370 Fresh air inlet W2 Wire control box Door 326 Door N2 300 N Wire control box 20 80 Fresh air inlet 50 1650 Air return vent 50 VRF Heat Recovery Ventilation | Technical features Model Indoor unit SYSVRF Art. no. Power supply HRV 500 Q HRV 1000 Q 314289 314290 V/Ph/Hz 314291 380/3/50 500/500/375 1.000/1.000/750 External static pressure (H/M/L) Pa 80/68/45 100/85/58 170 Power input W 170 360 1.340 Enthalpy exchange efficiency/ Cooling (H/M/L) % 50/50/55 50/50/55 50 Enthalpy exchange efficiency/ Heating (H/M/L) % 60/60/65 60/60/65 60 Temperature exchange efficiency (H/M/L) % 65/65/70 65/65/70 65 dB(A) 35/34/28 40/39/33 53 1.020x1.036x270 1.276x1.269x388 1.650x1.470x540 35 69 165 ⌀194 ⌀242 346x326 Air flow rate (H/M/L) Sound pressure level (H/M/L) Dimensions (LxWxH) Unit weight m3/h 220-240/1/50 HRV 2000 R mm kg Duct connection dimensions Ambient condition mm °C 2.000 -7…+43/ max 80% RH Fan performance Air flow (m3/h) SYSVRF HRV 500 Q External static pressure (Pa) Air flow (m3/h) SYSVRF HRV 1000 Q External static pressure (Pa) Air flow (m3/h) SYSVRF HRV 2000 Q External static pressure (Pa) Nominal conditions Exhaust air Fresh air Cooling mode 27°C DB, 19,5°C WB 35°C DB, 28°C WB Heating mode 21°C DB, 13°C WB 5°C DB, 2°C WB The sound pressure value may vary depending on ambient conditions. 81 82 | VRF connection to AHU Connection to DX coil SYSCONTROL AHU Features The SYSCONTROL AHU 5HP, 10HP and 20HP can be used to connect the SYSVRF outdoor units to an external DX coil with capacity from 9 kW to 56 kW. Nominal capacity in cooling 14kW (5HP), 28kW (10HP) and 56kW (20HP). Modulating cooling/heating capacity thanks to the built-in Electronic Expansion Valve (EXV) controlled by the superheat degree of the DX coil. The SYSCONTROL AHU kit includes four temperature sensors, one for the air intake of the AHU and three for a precise monitoring of the DX evaporator coil. For indoor installation in horizontal or vertical position. Failure alarm codes on the PCB for quick service checking. Environment friendly R410A refrigerant. Connection to Systemair network monitoring system. Wired controller SYSCONTROL WC 29 (standard) Wired controllor SYSCONTROL WC 29 as standard equipment. Connection diagram max 8 m SYSVRF indoor units SYSCONTROL AHU max 175 m SYSVRF outdoor unit FRICO Air Curtain max 8 m SYSCONTROL AHU SYSTEMAIR Air Handling Unit Technical features Model AHU box Art. no. Power supply DX coil capacity Air volume SYSCONTROL AHU 10HP SYSCONTROL AHU 20HP 314188 314189 314190 V/Ph/Hz kW m3/h Dimensions (LxWxH) mm Packing (LxWxH) mm Piping diameters in/out mm IP-class Max current (1Ph motor) SYSCONTROL AHU 5HP A 220-240/1/50, 208-230/1/60 9-20 20-36 36-56 1.400~2.700 3.000~4.500 5.400~7.500 375x350x150 490x240x420 8/8 12,7/12,7 15,9/15,9 IP X0 IP X0 IP X0 5 30 30 VRF connection to AHU | SYSVRF selection and designing software Selection and designing software for all SYSVRF systems, 2-pipe, 3-pipe and Mini-VRF. Main tasks: Calculation of the heat loads and selection of the necessary cooling /heating capacity, type and location of outdoor and indoor units. Calculation of the refrigerant piping diameters and the required additional amount of refrigerant. Selection of an optimal set of piping joints. Building Management System. Correction of the performance of indoor units. Automatic check of the circuit for compliance requirements and limits on the maximum length of refrigerant pipelines and indoor-outdoor elevations. Conclusion of project documentation - specification (Excel), a detailed specification with the drawings (Word), and print out of all documents. 83 84 | VRF control systems SYSCONTROL systems Remote control for indoor units Wireless infrared remote control SYSCONTROL RM 02 Main functions: on/off, cool/heat/auto/dry/fan mode of the air conditioner, temperature setting , fan speed selection (high/medium/low/auto), 24h on/off timer, TURBO mode, ECO mode, air flow/swing adjustment, display backlight button, FOLLOW ME functions, keyboard locking function, 26 °C button. Standard equipment for SYSVRF WALL, CASSETTE, CEILING. For 2-pipe and 3-pipe SYSVRF. (Art. no. 314138). Wired controller SYSCONTROL WC 90 Main functions: on/off, cool/heat/auto/dry/fan mode of the air conditioner, temperature setting, fan speed selection (high/medium,low/auto), real 24h on/off timer, swing button. Standard equipment for SYSVRF DUCT, DUCT HP. Designed for 2-pipe SYSVRF HP with automatic cooling/heating changeover. It can be used for 3-pipe SYSVRF HR with manual cooling/heating changeover. (Art. no. 314139). Wired controller SYSCONTROL WC 120 Main functions: on/off, cool/heat/auto/dry/fan mode of the air conditioner, temperature setting , fan speed selection (high/medium/low/auto), 24h on/off timer, air flow/swing adjustment, air filter function, keyboard locking button. Optional equipment for all series of SYSVRF indoor units. Specifically designed for 3-pipe SYSVRF HR systems with automatic cooling/heating changeover and adjustable dead band. It can be used in 2-pipe SYSVRF HP systems. (Art. no. 314182). Centralized controllers Centralized controller SYSCONTROL CWC 03 HP/HR Monitors and manages 64 indoor units. Main functions: on/off, setting modes (including the lock mode), change temperature settings, fan speed selection, query function and error code of indoor units LCD with backlight. Provides the ability to connect to a PC via a converter RS485/RS232. (Art. no. 314140) CWC 03 HP for 2-pipe SYSVRF HP. (Art. no. 314183) CWC 03 HR for 3-pipe SYSVRF HR. Centralized controller SYSCONTROL CWC 09 Monitors and manages 64 indoor units. Perform the same functions of the central control SYSCONTROL CWC 03, with the possibility of drawing up management program for the week. LCD with backlight it doesn't have the port for the connection to a PC. (Art. no. 314141). Centralized monitoring of outdoor units SYSCONTROL CWC 02 Monitors up to 32 outdoor units which may be included in the 8 different VRF air conditioning systems. When using a powermeter tra performs the accounting function of electricity consumed. Ability to connect to a PC via a converter RS485/RS232. (Art. no. 314142). VRF control systems | Intelligent Network Management System Systemair multi-zone system can be integrated into a comprehensive building management system (BMS) thanks to the Bacnet, Modbus or LonWorks gateway via SYSCONTROL CWC 08/CWC 11/CWC 64, respectively. With the implementation of these gateway it is possible to use different control schemes: individual, group, network. To one gateway Bacnet SYSCONTROL CWC 08 (Art. no. 314145) can be connected to up to 4 remote central control (SYSCONTROL CWC 02 /SYSCONTROL CWC 03). Each group can contain a maximum of 64 indoor units/32 outdoor units. Bacnet SYSCONTROL RM 02 SYSCONTROL WC 90/WC 120 Max 64 SYSCONTROL CWC 03 Bacnet BMS Max 64 SYSCONTROL CWC 08 SYSCONTROL CWC 03 Max 64 SYSCONTROL CWC 03 Power digital motor Max 32 S SCO RO SYSCONTROL CWC 02 The central management console (SYSCONTROL CWC 03) can be connected to one gateway Modbus SYSCONTROL CWC 11 (Art. no. 314143). Each group can contain a maximum of 64 indoor units. Modbus Modbus BMS SYSCONTROL RM 02 SYSCONTROL WC 90/WC 120 Max 64 SYSCONTROL CWC 11 SYSCONTROL CWC 03 Up to 64 indoor units can be directly connected to one gateway Lonworks SYSCONTROL CWC 64 (Art. no. 314144). LonWorks Lonwork BMS SYSCONTROL RM 02 SYSCONTROL CWC 64 SYSCONTROL WC 90/WC 120 Max 64 85 86 | VRF piping joint Piping joints for 2-pipe refrigerant system SYSVRF JOINT Outdoor unit Model Art. no. Packing LxWxH (mm) Gross weight (kg) SYSVRF JOINT OUT 02 HP 314146 255x150x185 1,5 Connect two outdoor units of SYSVRF AIR EVO HP R series Use SYSVRF JOINT OUT 03 HP 314147 345x160x285 3,4 Connect three outdoor units of SYSVRF AIR EVO HP R series SYSVRF JOINT OUT 04 HP 314148 475x165x300 4,8 Connect four outdoor units of SYSVRF AIR EVO HP R series Model Art. no. Packing LxWxH (mm) Gross weight (kg) SYSVRF JOINT IN 01 2P 314149 290x105x100 0,4 Capacity of connected indoor units < 23 kW SYSVRF JOINT IN 02 2P 314150 290x105x100 0,6 Capacity of connected indoor units 23-33 kW SYSVRF JOINT IN 03 2P 314151 310x130x125 0,9 Capacity of connected indoor units 33-92 kW SYSVRF JOINT IN 04 2P 314152 350x180x170 1,5 Capacity of connected indoor units 92-135 kW SYSVRF JOINT IN 05 2P 314153 365x195x215 1,9 Capacity of connected indoor units > 135 kW SYSVRF JOINT IN 06 2P 314154 390x230x255 3,1 Capacity of connected indoor units 185 kW and long piping Indoor unit Use Piping joints for 3-pipe refrigerant system SYSVRF JOINT Outdoor unit Model Art. no. Packing LxWxH (mm) Gross weight (kg) SYSVRF JOINT OUT 02 HR 314155 272×167×232 2,2 Connect two outdoor units of SYSVRF AIR EVO HR R series Use SYSVRF JOINT OUT 03 HR 314156 472×157×312 5,0 Connect three outdoor units of SYSVRF AIR EVO HR R series SYSVRF JOINT OUT 04 HR 314184 745×160×335 7,5 Connect four outdoor units of SYSVRF AIR EVO HR R series Art. no. Packing LxWxH (mm) Gross weight (kg) Indoor unit Model Use SYSVRF JOINT IN 01 3P 314157 257×127×107 0,8 Capacity of connected indoor units < 16,6kW SYSVRF JOINT IN 02 3P 314158 287×137×107 0,9 Capacity of connected indoor units 16,6-33kW SYSVRF JOINT IN 03 3P 314159 297×167×177 1,4 Capacity of connected indoor units 33-66kW SYSVRF JOINT IN 04 3P 314160 372×197×187 2,3 Capacity of connected indoor units 66-92kW SYSVRF JOINT IN 05 3P 314185 432×222×227 3,3 Capacity of connected indoor units > 92kW www.systemair.com
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project