Catalogo%20Split%20e%20VRF_2015.

Catalogo%20Split%20e%20VRF_2015.
Split, Multi and VRF systems
Air conditioning
Residential and Light Commercial
Systemair Trust
We consider your trust in us as a supplier an important goal. It is always included in our work
on all levels and in all areas whether it is a question of cooperation, quality, deliveries or
documentation. This catalogue is of course a part of this work.
With this catalogue, which features products of air conditioning, we want to give you as a
customer a general overview of what Systemair can offer within this field. More detailed
information is available in our Online catalogue at www.systemair.com and as downloadable
software. Systemair’s range of fans, air distribution products and accessories also appears in our
printed main catalogue.
Our product development leads the field - latest technologies in unitdesign, fans, motors,
heat recovery, chillers, fan coils,... interact to give high efficiency and with that low power
consumption. Systemair has grown each year since the start and we aim to continue with this
trend.
Systemair strives to be a reliable supplier of quality products. We help our customers to focus on
their own business. Reliable deliveres give the customers greater possibilities to quickly complete
a job, and move on to the next project.
At Systemair we call this Trust.
© Systemair 2013.
Systemair reserves the right to make technical changes. For updated documentation, please refer to www.systemair.com
Content |
Content
Systemair
4
Product Range
6
Application
8
SPLIT systems
10
Wall-mounted series
14
Multi systems
20
Light-commercial series
32
VRF systems
40
Outdoor units
44
Indoor units
60
Ventilation application
Controls and accessories
80
84
3
4
| Systemair
Systemair worldwide
Skinnskatteberg, Sweden:
Windischbuch, Germany:
Ukmerge, Lithuania:
Systemair AB, the Systemair group head office
is in Skinnskatteberg, Sweden. The production
is virtually fully automated with modern
machinery featuring advanced computer
support. Also located here is the company’s
most advanced test installation for measuring
technical data.
Production facility for fans and modular air
handling units, specialized on engineered
products (e.g. tunnel and jet fans).
Distribution center.
Production of smaller air handling units with
energy recovery systems.
Klockgården, Sweden:
Hässleholm, Sweden:
Systemair’s small air handling units
are manufactured at Klockgården in
Skinnskatteberg. Frico’s central warehouse of
approximately 8000 m2 is also located here.
Langenfeld, Germany:
Production of air curtains.
VEAB is the leading European manufacturer of
electric duct heaters. Production of heating and
cooling coils, electric and water based.
Maribor, Slovenia:
Specialized in centrifugal smoke extract fans,
EN certified.
Hasselager, Denmark:
Production of modular air handling units.
Dal Eidsvoll, Norway:
Production of air handling units.
Systemair |
Save energy, lower running cost!
Quality:
Systemair is certified in accordance with ISO
9001; ISO 14001 and ATEX. Our research and
development laboratories are one of the most
modern in Europe; measurements are made in
accordance with international standards like
AMCA and ISO.
Dal, Eidsvoll, Norway
Hasselager, Denmark
Bouctouche, Canada
Kansas City, USA
Waalwijk, Netherlands
Windischbuch, Germany
Tillières-sur-Avre, France
Barlassina, Italy
Madrid, Spain
Our label “Green Ventilation” features products with a
high energy saving potential.
All products labelled with “Green Ventilation” combine
energy economy with energy efficiency.
Skinnskatteberg, Sweden
Hässleholm, Sweden
Ukmerge, Lithuania
Langenfeld, Germany
Bratislava, Slovakia
Maribor, Slovenia
Istanbul, Turkey
New Delhi, India
Hyderabad, India
Kuala Lumpur, Malaysia
Bratislava, Slovakia:
New Delhi, India:
Kansas City, USA:
The factory in Bratislava manufactures air
distribution products and EN certified fire and
smoke dampers.
The factories in New Delhi and Noida
manufacture grilles and diffusers.
Production of fans for the US market.
Kuala Lumpur, Malaysia:
Barlassina, Italy:
Systemair-HSK is Turkey‘s leading manufacturer
of air handling units.
Production and marketing of products for Tunnel
and garage ventilation.
Our factory in Italy, Systemair, develops and
manufactures a wide range of chiller and heat
pump in A class from 20 to 1.600kW.
Madrid, Spain:
Bouctouche, Canada:
Production of air handling units for the southern
European market.
Hyderabad, India:
Production if air distribution products.
5
Our main North American production facility
of air handling units and inline fans for
commercial and residential applications is
located in Bouctouche.
Istanbul, Turkey:
Waalwijk, Netherlands:
Holland Heating is Netherlands leading
manufacturer of air handling units.
Tillières-sur-Avre, France:
Our factory in Italy, Systemair, develops and
manufactures: Roof top, water source heat
pump, hight temperature heat pump, water
terminals.
6
| Product range
Product range
Systemair has an extensive range of ventilation products: fans including smoke
extract, tunnel and car park fans, explosion proof fans, air handling units
from large central units to small residential units with energy recovery, air
distribution products and fire dampers. These products are installed in a variety
of locations, including homes, offices, healthcare premises, shops, industrial
buildings, tunnels, parking garages, training facilities, sports centres etc.
Fans
Duct fans
Rectangular duct fans
Systemair has the wider range of
fans for use in different applications.
Our range includes any type of fans,
from circular ducts – hystorical
product – boxed up to those of
extraction, axial, and explosion-proof
for the extraction of fumes.
All products listed above are made in
different dimensions from 100 mm
in diameter to fans of large size for
tunnel. All our fans are designed to
meet the strict requirements, easy to
use, high quality and durability.
Duct fans for circular duct installation.
Duct fans with rectangular connection.
Centrifugal fans
Centrifugal supply single fans.
Square duct fans
For different applications, there are
models for ambient with high temperature.
Axial fans
Axial fans for duct or wall application.
Roof fans
Roof fans with circular or square connection.
Jet Axial Fans
Jet Axial Fans for car park, tunnels
and air overpression.
High temperature fans
Systemair provides high fire resistance fans till 600°C/2 hours.
Explosion proof fans
Explosion proof fans in duct, roof or
wall design.
Product range |
Air handling units
Systemair produces a wide range
of air handling units for several applications, from small office to large
industrial building. All range is been
developped to satisfy strict needs of
low energy consumption.
Fire and smoke dampers
Smoke extract fans
High efficient fans to extract the
combustion smoke.
Fire & smoke dampers
Dampers that reduce the spread of
smoke and fire.
Residential ventilation
Residential units
Cooker hoods
Complete energy-efficient air handling units with heat recovery and
built in control systems.
Designed to be mounted over the
cooker, on walls or horizontally in
attics.
For homes with living areas of 60320 m 2.
Ideal for capturing odours even at
low airflows.
Air distribution products
Supply, extract & transfer devices
For mounting in ceilings or walls.
Nozzle diffusers
Optimum flexibility and comfort in air
distribution for rooms.
The range also includes a wide
selection of air distribution products
and accessories.
Air Conditioning
The strengh point of Systemair
Air Conditioning products is a wide
range with several options and
accessories: chiller, water terminals,
close control etc.
7
Applications
Schools
In buildings for school, the load to be disposed is variable during the day due to the
presence of people only for some periods, thus it is mandatory to control the users
requirements during daily plant use. Systemair offers a wide range of equipment
suitable for this purpose, the fan coils with EC motors allow to obtain the required
flexibility.
Offices
In buildings for tertiary application, the air conditioning and the ventilation are
necessary during the day.
The heat loads to be removed are generally generated by people present, from the
lighting system, from solar radiation and by machines.
Normally it is necessary the use of chillers, Heat Pump to produce cold and/or hot
water to be sent to hydronic (fan coils, cassettes, ducted) to obtain an optimum air
conditioning of offices.
Commercial buildings
Normally the number of people varies continuously; the optimal solution would
be to use machinery for the conditioning with variable flow and with constant
monitoring of concentration of pollutants (VOC and CO2). Systemair products can
easily meet the plantʼs requirement .
Industry
Industrial plants generate a large amount of heat that must be dissipated in the
appropriate way. Systemair offers a wide range of products (chillers from 20 kW
to 1.680 kW) that can be readily integrated industrial installation. The chiller can be
used both for air conditioning and for the cooling equipment process (production of
chilled water up to -10°C).
Hotels
In the hotel rooms, it is needed a high level of comfort with the minimum impact with
respect to the noise level. Systemair ducted products equipped with EC motors fully
comply with requirements efficiency, cooling capacity and sound impact , required by
this type of installations.
SYSPLIT
Split and Multi systems |
SYSPLIT air conditioners Systemair:
residential and light commercial split systems
The SYSPLIT air conditioner range are specifically
designed for small to medium sized areas, offering
the end user improved comfort and reducing drastically
the power consumption.
The expanded range of SYSPLIT air conditioners is of
superior performance and quality, providing more choice
for customers.
Our innovative products offer the ideal solution when you
need quiet and efficient room air conditioning to create
a comfortable environment.
In addition to Single Split systems, Systemair also offers
the SYSPLIT MULTI – an advanced range of inverter Heat
Pump Multi Split Systems with up to 5 indoor units of
different types that can be connected.
All SYSPLIT inverter systems utilise the non-ozone
depleting R410A refrigerant, which gives increased
system performance, increased energy-efficiency and
improved heat transfer, which results in smaller pipe sizes
and more compact indoor units.
The latest generation of SYSPLIT air conditioners are
among the most technically advanced and energyefficient systems available today.
SYSPLIT Single and Multi systems
SYSPLIT WALL EVO PH
14
SYSPLIT MULTI rated capacity
25
SYSPLIT WALL EVO HP
16
SYSPLIT CASSETTE EVO HP
30
SYSPLIT WALL INV HP
18
SYSPLIT CEILING EVO HP
32
SYSPLIT MULTI EVO HP
20
SYSPLIT DUCT EVO HP
34
SYSPLIT MULTI combination
22
SYSPLIT DUCT HT
36
11
12
| Split and Multi systems
Ecodesign regulation
ErP Directive 2009/125
The new regulation have been adopted by the European
Parliament to achieve the goals to reduce the power
consumption in Europe related to air conditioning business
and other home appliance as well as air-to-water heat
pump, air handling, ventilation etc.
With its strategic plan called “20/20/20”, Europe aims
to reduce the CO2 emissions by 20%, using 20% more
renewable energy and consuming 20% less primary
energy by 2020.
In order to facilitate the achievement of these objectives,
EU issued the ErP Directive that specifies the eco-design
20%
less emissions
of CO2 gas
requirements for placing on the market the energy-using
products.
For split air conditioners with power less than 12 kW,
the minimum requirements are based on a new index
of seasonal efficiency and on the sound power level as
shown in the table below:
A/C <6 kW
SEER/SCOP min.
SCOP
SEER
SCOP
4,6
3,8
4,3
3,8
Lw indoor max.
60 dB(A)
65 dB(A)
Lw outdoor max.
65 dB(A)
70 dB(A)
20%
more use
of renewable
energy
Measuring the performance in real conditions
The European Union requires the application of objective
metrics for measuring performance in order to establish
the minimum requirements and provide customers with
information regarding the performance of air conditioning
useful for their purchase.
The methodology used up to 2012 and based on the
efficiency rating (EER) – presents a significant difference
between the predicted and actual performance. For this
reason a more accurate method has beed designed: the
seasonal efficiency ratio (SEER).
A/C 6-12 kW
SEER
20%
less use of
primary energy
Among the most significant changes it includes the
introduction of different operating temperatures for
cooling and heating, the possibility of use of energy both
at partial load and full load and power usage in standby
and off mode.
Considering that most systems operate mostly in partload conditions, the new methodology will allow to assess
better the performance of a unit in real conditions.
Split and Multi systems |
New energy classification
New energy classification in force from 1 January 2013
The transition to the concept of seasonal efficiency
involves the development of a completely new energy
label which shows the energy class based on the values
of SEER and SCOP and the main characteristics of the
product such as the sound power level of the indoor and
outdoor units.
Energy efficiency in heating is presented with three
different values according to the climate where the
product is installed. For the manufacturer of the product
is mandatory to indicate the values for the Temperate
climate (“Averge” heating value), those of the other two
climates are optional. The data and energy efficiency
classes are declared in accordance with EN14825.
The energy class shown in the new label, both in cooling
and in heating, can not be compared to the energy class
that had the old energy label as the latter was based on
specific indices (EER and COP) and not on seasonal indices
SEER and SCOP.
The energy efficiency classes for split air conditioners are shown in the table below:
SEER
SCOP
A+++
Energy Efficiency Class
SEER ≥ 8,50
SCOP ≥ 5,10
A++
6,10 ≤ SEER < 8,50
4,60 ≤ SCOP < 5,10
A+
5,60 ≤ SEER < 6,10
4,00 ≤ SCOP < 4,60
A
5,10 ≤ SEER < 5,60
3,40 ≤ SCOP < 4,00
B
4,60 ≤ SEER < 5,10
3,10 ≤ SCOP < 3,40
C
4,10 ≤ SEER < 4,60
2,80 ≤ SCOP < 3,10
D
3,60 ≤ SEER < 4,10
2,50 ≤ SCOP < 2,80
E
3,10 ≤ SEER < 3,60
2,20 ≤ SCOP < 2,50
F
2,60 ≤ SEER < 3,10
1,90 ≤ SCOP < 2,20
G
SEER < 2,60
SCOP < 1,90
13
14
| Hi-wall Inverter Polar Split
Hi-wall Inverter Polar Split
SYSPLIT WALL EVO PH
Features
SYSPLIT WALL EVO PH assures superior performance even
in harsh outdoor conditions with an unique and exclusive
design.
Advanced DC inverter control for the compressor,
outdoor fan motor and indoor fan motor.
Cooling and heating operation down to -20 °C outdoor
temperature assures an operation all year round.
Self-diagnosis function continuosly monitors the
operation of the air conditioner and protects the system.
Refrigerant leakage detection can prevent the
compressor being damaged by refrigerant leakage or
compressor overload.
The active carbon filter ensures excellent performance
to remove odours, pollen and ammonia.
The heating belt fitted on the base plate of the outdoor
unit avoids the accumulation of rain, snow or defrosted
water.
Hydrophylic aluminium fins of the indoor units improve
the heat exchange efficiency in cooling and heating
mode.
The crankcase heater wrapped around the compressor
eusares safe start at very low outdoor temperature.
Power factor capacitors included in the outdoor unit
allow an active PF around 97%.
Infrared remote
control
SYSCONTROL
RM 52
(standard)
With the Auto-restart function the unit resumes with
the same settings before the electric power failure.
Environment friendly R410A refrigerant.
Infrared remote control SYSCONTROL RM 52 included.
Dimensions
SYSPLIT WALL IN
SYSPLIT WALL OUT
D
B
A
Air inlet
B
C
C
Air inlet
A
E
Air outlet
Model
09
12
18
24
Model
09
12
18
24
A
835
990
990
1.186
A
760
760
845
900
B
198
218
218
258
B
590
590
700
860
C
280
315
315
340
C
285
285
320
315
D
530
530
560
590
E
290
290
335
333
Hi-wall Inverter Polar Split |
Technical features
Model Indoor unit
SYSPLIT WALL
IN 09 EVO PH Q
IN 12 EVO PH Q
IN 18 EVO PH Q
IN 24 EVO PH Q
Model Outdoor unit
SYSPLIT WALL
OUT 09 EVO PH Q
OUT 12 EVO PH Q
OUT 18 EVO PH Q
OUT 24 EVO PH Q
Art. no. Indoor unit
314055
314265
314266
314267
Art. no. Outdoor unit
314268
314269
314270
314271
R410A / 1,1
R410A / 1,15
R410A / 1,15
R410A / 2,2
kW
2,90 (1,24-4,06)
3,69 (1,71-5,17)
Power consumption
W
810 (125~1.560)
Operating current
A
Refrigerant / Charged quantity
Power supply
kg
V/Ph/Hz
Cooling capacity
220-240/1/50
5,28 (1,94-6,23)
7,33 (3,48-8,09)
1.048 (173~1.990) 1.640 (147~2.394) 2.102 (297~3.111)
3,10 (0,54~6,79)
4,35 (0,75~8,65)
6,77 (0,64~10,4)
9,62 (1,29~13,5)
EER
3,58
3,52
3,22
3,49
SEER
6,9
7,0
6,9
7,1
Energy label cooling
A++
A++
A++
A++
5,86 (1,55-6,59)
8,50 (2,77-8,72)
Heating capacity
kW
2,93 (1,02-4,25)
3,87 (1,32-5,61)
Power consumption
W
620 (169~1.520)
983 (233~2.000)
Operating current
A
1.420 (270~2.355) 1.755 (417~3.115)
2,95 (0,73~6,6)
3,56 (1,01~8,71)
7,4 (1,17~10,2)
8,03 (1,8~13,5)
COP
4,73
3,94
4,13
4,84
SCOP (Average)
4,1
4,1
4,0
4,1
Energy label heating
A+
A+
A+
A+
Indoor Unit
m3/h
630/490/380
820/670/560
1.090/830/690
1.300/1.210/990
Sound pressure level (H/M/L)
dB(A)
41/33/25
44/38/31
47/40/31
49/43/37
Sound power level (H)
dB(A)
54
55
57
61
Air flow rate (H/M/L)
Dimensions LxWxH
mm
835x198x280
990x218x315
990x218x315
1.186x258x340
Packing LxWxH
mm
910x270x355
1.065x300x400
1.065x300x400
1.265x420x340
9/11
11,5/14
12/15
17,5/22
Net/gross weight
kg
Outdoor Unit
Compressor
Type
Rotary
Twin-rotary
Sound pressure level (H)
dB(A)
42
44
48
49
Sound power level (H)
dB(A)
59
61
65
66
Dimensions LxWxH
mm
760x285x590
760x285x590
845x320x700
900x315x860
Packing LxWxH
mm
887x355x645
887x355x645
965x395x755
1.043x395x915
Net/gross weight
Piping diameters
35/37
35/38
47/50
60/64
Liquid
mm (inch)
kg
6,35 (1/4”)
6,35 (1/4”)
6,35 (1/4”)
9,52 (3/8”)
Gas
mm (inch)
15,9 (5/8”)
9,52 (3/8”)
9,52 (3/8”)
12,7 (1/2”)
mm
16
16
16
16
Max. input current
A
9,5
11,5
14,0
16,0
Maximum lenght of the line
m
25
25
30
50
Maximum height difference
m
10
10
20
25
Indoor temperature
°C
+17…+32 cooling / heating 0 … +30
Outdoor temperature
°C
-20 ... +50 cooling / heating -20 ... +30
Drainage
Nominal conditions
Indoor unit
Outdoor unit
Piping lenght
Level difference
Cooling mode
27°C DB, 19°C WB
35°C DB
5m
0m
Heating mode
20°C DB, 19°C WB
7°C DB, 6°C WB
5m
0m
Seasonal efficiency according to EN 14825.
The sound pressure value may vary depending on ambient conditions.
15
16
| Hi-wall Inverter High efficiency Split
Hi-wall Inverter High efficiency Split
SYSPLIT WALL EVO HP
Features
SYSPLIT WALL EVO HP combines cutting-edge technology
with elegant and smooth shapes which can fit any interior
decor, providing seasonal performance up to 7,0 (SEER).
Advanced DC inverter control for the compressor,
outdoor fan motor and indoor fan motor.
Cooling and heating operation down to -15 °C outdoor
temperature assures an operation all year round.
Self-diagnosis function continuosly monitors the
operation of the air conditioner and protects the system.
Refrigerant leakage detection can prevent the
compressor being damaged by refrigerant leakage or
compressor overload.
The cold catalyst filter effectively decomposes volatile
compounds and it has anti-bacteria effect. It is
washable and maintains the effect for long time.
With Turbo mode the unit will run with the ultra-high
speed for 20 minutes, reaching more quickly the setpoint temperature.
Hydrophylic aluminium fins of the indoor units improve
the heat exchange efficiency in cooling and heating
mode.
Power factor capacitors included in the outdoor unit
allow an active PF around 97%.
Infrared remote
control
SYSCONTROL
RM 52
(standard)
With the Auto-restart function the unit resumes with
the same settings before the electric power failure.
Environment friendly R410A refrigerant.
Infrared remote control SYSCONTROL RM 52 included.
Dimensions
SYSPLIT WALL IN
SYSPLIT WALL OUT
D
B
A
Air inlet
B
C
C
Air inlet
A
E
Air outlet
Model
09
12
18
24
Model
09
12
18
24
A
835
835
990
1.186
A
780
810
810
845
B
198
198
218
258
B
540
558
558
700
C
280
280
315
340
C
250
310
310
320
D
549
549
549
560
E
276
325
325
335
Hi-wall Inverter High efficiency Split |
Technical features
Model Indoor unit
SYSPLIT WALL
IN 09 EVO HP Q
IN 12 EVO HP Q
IN 18 EVO HP Q
IN 24 EVO HP Q
Model Outdoor unit
SYSPLIT WALL
OUT 09 EVO HP Q
OUT 12 EVO HP Q
OUT 18 EVO HP Q
OUT 24 EVO HP Q
Art. no. Indoor unit
314017
314018
314019
314167
Art. no. Outdoor unit
314004
314005
314006
314007
R410A / 1,03
R410A / 1,03
R410A / 1,65
R410A / 1,95
kW
2,78 (1,28~3,54)
3,66 (1,31~4,76)
Power consumption
W
803 (113~1.360)
1.071 (99~1.830)
1.670 (147~2.390) 2.147 (195~2.850)
Operating current
A
Refrigerant / Changed quantity
Power supply
kg
V/Ph/Hz
Cooling capacity
220-240/1/50
5,28 (1,93~6,23)
6,45 (2,22~7,42)
3,49 (0,49~5,91)
4,66 (0,43~7,96)
7,26 (0,64~10,41)
9,45 (0,85~12,4)
EER
3,47
3,42
3,16
2,97
SEER
6,5
7,0
6,4
6,2
Energy label cooling
A++
A++
A++
A++
5,57 (1,20~6,76)
7,33 (1,57~9,09)
Heating capacity
kW
2,88 (1,27~3,56)
3,75 (1,03~4,95)
Power consumption
W
627 (160~1.270)
991 (162~1.770)
Operating current
A
1.495 (231~2.490) 2.232 (284~3.240)
2,73 (0,7~5,53)
4,31 (0,7~7,69)
6,50 (1,0~10,81)
9,70 (1,23~14,11)
COP
4,59
3,78
3,73
3,28
SCOP (Average)
4,0
4,1
4,0
4,0
Energy label heating
A+
A+
A+
A+
Indoor Unit
m3/h
650/530/400
700/580/500
1.250/980/820
1.450/1.300/1.200
Sound pressure level (H/M/L)
dB(A)
43/38/28
43/37/31
48/41/35
49/46/42
Sound power level (H)
dB(A)
56
57
60
63
Air flow rate (H/M/L)
Dimensions LxWxH
mm
835x198x280
835x198x280
990x218x315
1.186x258x340
Packing LxWxH
mm
910x270x355
910x270x335
1.065x300x400
1.265x420x340
8/10
9/11,5
12/15
17/22
Net/gross weight
kg
Outdoor Unit
Compressor
Type
Rotary
Twin-rotary
Sound pressure level (H)
dB(A)
45
45
47
Sound power level (H)
dB(A)
62
62
64
52
69
Dimensions LxWxH
mm
780x250x540
810x310x558
810x310x558
845x320x700
Packing LxWxH
mm
910x335x585
930x400x615
930x400x615
965x395x755
28/30
30,5/33
37/39
47/50,5
Net/gross weight
Piping diameters
kg
Liquid
mm (inch)
6,35 (1/4”)
6,35 (1/4”)
6,35 (1/4”)
9,52 (3/8”)
Gas
mm (inch)
15,9 (5/8”)
9,52 (3/8”)
9,52 (3/8”)
12,7 (1/2”)
mm
16
16
16
16
Max. input current
A
9,0
11,5
11,5
13,5
Maximum lenght of the line
m
25
25
30
30
Maximum height difference
m
10
10
20
20
Indoor temperature
°C
+17…+32 cooling / heating 0 … +30
Outdoor temperature
°C
-15 ... +50 cooling / heating -15 ... +30
Drainage
Nominal conditions
Indoor unit
Outdoor unit
Piping lenght
Level difference
Cooling mode
27°C DB, 19°C WB
35°C DB
5m
0m
Heating mode
20°C DB, 19°C WB
7°C DB, 6°C WB
5m
0m
Seasonal efficiency according to EN 14825.
The sound pressure value may vary depending on ambient conditions.
17
18
| Hi-wall Inverter Split
Hi-wall Inverter Split
SYSPLIT WALL INV HP
Features
SYSPLIT WALL INV are the most affordable and reliable
solution for small offices and residential premises.
High efficient DC inverter control provides accurate
regulation of the room temperature.
Stylish appearance with big LCD showing all main
settings of the air conditioner.
Outdoor units are equipped with valve protection
cover.
Self-diagnosis function continuosly monitors the
operation of the air conditioner and protect the
system.
Refrigerante leakage detection can prevent the
compressor being damaged by refrigerant leakage
or compressor overload.
The cold catalyst filter effectively decomposes
volatile compounds and it has anti-bacteria effect. It is
washable and maintains the effect for long time.
With Turbo mode the unit will run with the ultra-high
speed for 20 minutes to reach more quickly the
set-point temperature.
Hydrophylic aluminium fins of the indoor units improve
the heat exchange efficiency in cooling and heating
mode.
Infrared remote
control
SYSCONTROL
RM 52
(standard)
Power factor capacitors included in the outdoor unit
allow an active PF around 97%.
With the Auto-restart function the unit resumes with
the same settings before the electric power failure.
Environment friendly refrigerant R410A.
Infrared remote control SYSCONTROL RM 52 included.
Dimensions
SYSPLIT WALL IN
SYSPLIT WALL OUT
D
B
A
Air inlet
B
C
C
Air inlet
A
E
Air outlet
Model
09
12
18
24
Model
09
12
18
24
A
800
800
940
1.045
A
780
780
760
845
B
188
188
205
235
B
540
540
590
700
C
275
275
275
315
C
250
250
285
320
D
549
549
530
560
E
276
276
290
335
Hi-wall Inverter Split |
Technical features
Model Indoor unit
SYSPLIT WALL
IN 09 INV HP Q
IN 12 INV HP Q
IN 18 INV HP Q
IN 24 INV HP Q
Model Outdoor unit
SYSPLIT WALL
OUT 09 INV HP Q
OUT 12 INV HP Q
OUT 18 INV HP Q
OUT 24 INV HP Q
Art. no. Indoor unit
314163
314164
314165
314166
Art. no. Outdoor unit
314000
314001
314002
314003
R410A / 0,8
R410A / 0,8
R410A / 1,25
R410A / 1,95
kW
2,64 (1,30~3,22)
3,22 (1,41~4,29)
Power consumption
W
790 (144~1.240)
Operating current
A
Refrigerant / Changed quantity
Power supply
kg
V/Ph/Hz
Cooling capacity
220-240/1/50
4,98 (1,91~5,90)
6,45 (2,18~7,09)
1.000 (139~1.650) 1.550 (157~2.270) 2.000 (204~2.730)
3,4 (0,63~5,39)
4,4 (0,60~7,17)
6,7 (0,68~9,87)
8,7 (0,89~11,87)
EER
3,34
3,22
3,21
3,23
SEER
5,6
5,6
6,1
5,9
Energy label cooling
A+
A+
A++
A+
kW
2,93 (1,01~3,45)
3,66 (0,98~4,54)
5,28 (1,27~6,23)
6,74 (1,60~8,65)
Power consumption
W
730 (175~1.230)
Operating current
A
3,2 (0,76~5,35)
4,4 (0,77~7,04)
6,2 (0,83~9,65)
7,9 (1,27~13,43)
COP
4,01
3,63
3,71
3,72
SCOP (Average)
3,8
3,8
3,8
3,8
A
A
A
A
Heating capacity
Energy label heating
1.010 (177~1.620) 1.420 (191~2.220) 1.810 (293~3.090)
Indoor Unit
m3/h
620/540/440
630/550/430
730/480/400
1.150/1.050/900
Sound pressure level (H/M/L)
dB(A)
41/38/31
43/40/31
41/33/31
49/47/41
Sound power level (H)
dB(A)
57
57
57
63
Air flow rate (H/M/L)
Dimensions LxWxH
mm
800x188x275
800x188x275
940x205x275
1.045x235x315
Packing LxWxH
mm
865x265x350
865x265x350
1.015x265x350
1.135x395x350
7,5/9,5
7,5/9,5
9/12,5
12,5/15,5
Net/gross weight
kg
Outdoor Unit
Compressor
Type
Rotary
Twin-rotary
Sound pressure level (H)
dB(A)
46
46
48
Sound power level (H)
dB(A)
63
63
65
51
68
Dimensions LxWxH
mm
780x250x540
780x250x540
760x285x590
845x320x700
Packing LxWxH
mm
910x335x585
910x335x585
887x355x645
965x395x755
28/30
28/30
34,5/37
47/50
Net/gross weight
Piping diameters
kg
Liquid
mm (inch)
6,35 (1/4”)
6,35 (1/4”)
6,35 (1/4”)
9,52 (3/8”)
Gas
mm (inch)
15,9 (5/8”)
9,52 (3/8”)
9,52 (3/8”)
12,7 (1/2”)
mm
16
16
16
16
Max. input current
A
9,0
11,5
12,5
13,5
Maximum lenght of the line
m
20
20
20
25
Maximum height difference
m
8
8
8
10
Drainage
Indoor temperature
°C
+17…+32 cooling / heating 0 … +30
Outdoor temperature
°C
0 ... +50 cooling / heating -15 ... +30
Nominal conditions
Indoor unit
Outdoor unit
Piping lenght
Level difference
Cooling mode
27°C DB, 19°C WB
35°C DB
5m
0m
Heating mode
20°C DB, 19°C WB
7°C DB, 6°C WB
5m
0m
Seasonal efficiency according to EN 14825.
The sound pressure value may vary depending on ambient conditions.
19
20
| Multi-split Inverter High efficiency
Multi-split Inverter High efficiency
SYSPLIT MULTI EVO HP
Features
SYSPLIT MULTI EVO are ideal and flexible solution for
providing quiet and efficient air conditioning for 2 to 5
areas from a single outdoor unit.
SYSPLIT MULTI outdoor units are compatible with SYSPLIT
WALL EVO, CASSETTE EVO and DUCT EVO indoor units.
DC inverter technology for precise temperature control
and a low start-up current.
Robust and reliable structure, cabinet made of zinc
steel sheet.
Outdoor units are equipped with valve protection cover.
Twin-rotary compressors assure high efficient
operation, minimal vibration and low noise level.
All indoor units are equipped with DC Inverter fan motor.
Hydrophylic aluminium fins improve the heat exchange
efficiency reducing the defrosting cycle time.
Cooling and heating operation down to -15°C outdoor
temperature assures an operation all year round.
Power factor capacitors included in the unit allow an
active PF around 97%.
With the Auto-restart function the unit resumes with
the same settings before the electric power failure.
Environment friendly refrigerant R410A.
B
Dimensions
SYSPLIT MULTI
A
B
E
C
D
A
Model
A
14
18
21
28
36
42
845
845
900
990
990
B
700
845 C
700
700
860
965
965
C
320
320
320
315
345
345
D
560D
560
560
590
624
624
E
335
335
335
333
366
366
E
Multi-split Inverter High efficiency |
Technical features
Model
SYSPLIT
MULTI2 14
EVO HP Q
Art. no. Outdoor unit
MULTI2 18
EVO HP Q
MULTI3 21
EVO HP Q
MULTI4 28
EVO HP Q
MULTI5 36
EVO HP Q
MULTI5 42
EVO HP Q
314011
314012
314013
314014
314015
314264
R410A / 1,55
R410A / 1,9
R410A / 2,1
R410A / 2,4
R410A / 3,0
R410A / 3,5
kW
4,11
5,26
6,16
8,20
10,56
12,30
Power consumption
W
1.260
1.600
1.900
2.470
3.280
3.730
Operating current
A
Refrigerant / Charged quantity
Power supply
kg
V/Ph/Hz
Cooling capacity
EER
220-240/1/50
5,7
7,0
8,3
11,2
14,6
17,1
3,26
3,29
3,24
3,32
3,22
3,30
SEER
6,1
6,3
6,4
6,4
5,7
-
Energy label cooling
A++
A++
A++
A++
A+
-
kW
4,68
6,15
6,74
9,08
12,31
12,30
Power consumption
Heating capacity
W
1.450
1.700
1.750
2.440
3.400
3.370
Operating current
A
6,5
7,4
7,6
11,1
15,3
15,4
COP
3,23
3,62
3,85
3,72
3,62
3,65
SCOP (Average)
4,0
4,2
4,1
3,8
3,8
-
Energy label heating
A+
A+
A+
A
A
Twin-rotary
Outdoor Unit
Type
Rotary
Twin-rotary
Twin-rotary
Twin-rotary
Twin-rotary
Sound pressure level (H)
Compressor
dB(A)
45
46
47
53
51
55
Sound power level (H)
dB(A)
62
63
64
70
68
72
900x315x860
990x345x965
990x345x965
Dimensions LxWxH
mm
845x320x700
845x320x700
845x320x700
Packing LxWxH
mm
965x395x755
965x375x755
965x395x755 1.043x395x915 1.120x435x1.100 1.120x435x1.100
Net/gross weight
Piping diameters
44/47
48/52
50/54
65/69
80/91
89/93
Liquid
inch
kg
2x 6,35 (1/4”)
2x 6,35 (1/4”)
3x 6,35 (1/4”)
4x 6,35 (1/4”)
5x 6,35 (1/4”)
5x 6,35 (1/4”)
Gas
inch
2x 9,52 (3/8”)
2x 9,52 (3/8”)
3x 9,52 (3/8”)
4x 9,52 (3/8”)
5x 9,52 (3/8”)
5x 9,52 (3/8”)
Max. input current
A
11,0
14,5
15,0
17,0
22,0
28,0
Maximum lenght all lines
m
30
30
45
60
75
75
Maximum lenght of the line
m
20
20
25
30
30
30
Maximum height difference
OU higher than IU/ OU lower than IU
m
10/15
10/15
10/15
10/15
10/15
10/15
Outdoor temperature
°C
-15 ... +50 cooling / heating -15 ... +24
Rated performance at 100% of combination. For combination exceeding 100% the cooling and heating capacities of the indoor units will be proportionally reduced.
Nominal conditions
Indoor unit
Outdoor unit
Piping lenght
Level difference
Cooling mode
27°C DB, 19°C WB
35°C DB
5m
0m
Heating mode
20°C DB, 19°C WB
7°C DB, 6°C WB
5m
0m
Seasonal efficiency according to EN 14825.
The sound pressure value may vary depending on ambient conditions.
21
22
| Multi-split indoor units
Indoor units for SYSPLIT MULTI EVO
Infrared remote control
SYSCONTROL RM 52
(standard)
Wall mounted indoor unit SYSPLIT WALL IN EVO HP Q
Model indoor unit
SYSPLIT WALL
Art. no. Indoor unit
IN 07 EVO HP Q
IN 09 EVO HP Q IN 12 EVO HP Q IN 18 EVO HP Q IN 24 EVO HP Q
314017
314018
314019
314167
Cooling capacity
kW
2,02
2,60
3,47
4,91
6,02
Heating capacity
kW
2,31
2,89
3,76
5,20
6,84
Power consumption
W
24
24
24
62
91
Operating current
A
0,11
0,11
0,11
0,28
0,40
m3/h
650/530/400
650/530/400
dB(A)
43/38/28
43/38/28
Air flow rate (H/M/L)
Sound pressure level (H/M/L)
Piping diameters
314016
700/580/500 1.250/980/820 1.450/1.300/1.200
43/37/31
48/41/35
49/46/42
Liquid
inch
6,35 (1/4”)
6,35 (1/4”)
6,35 (1/4”)
6,35 (1/4”)
9,52 (3/8”)
Gas
inch
9,52 (3/8”)
9,52 (3/8”)
9,52 (3/8”)
12,7 (1/2”)
15,9 (5/8”)
Drainage
mm
16
16
16
16
16
mm
835x198x280
835x198x280
835x198x280
990x218x315
1.186x258x340
8
8
9
12
17
Dimensions LxWxH
Unit weight
kg
Infrared remote control
SYSCONTROL RM 52
(standard)
Cassette indoor unit SYSPLIT CASSETTE EVO HP Q
Model indoor unit
SYSPLIT CASSETTE
07 EVO HP Q
09 EVO HP Q
12 EVO HP Q
M 18 EVO HP Q
MINI SPLIT
MINI SPLIT
MINI SPLIT
MINI SPLIT
Art. no. Indoor unit
314020
314021
314028
314171
Art. no. Panel unit
314032
314032
314032
314032
Model panel unit
SYSPANEL CASSETTE
Cooling capacity
kW
2,02
2,60
3,47
5,20
Heating capacity
kW
2,31
2,89
3,76
5,20
Power consumption
W
40
40
102
102
Operating current
A
0,18
0,18
0,44
0,44
m3/h
580
580
800
800
dB(A)
32
32
37
42
Air flow rate (H/M/L)
Sound pressure level (H)
Piping diameters
Liquid
inch
6,35 (1/4”)
6,35 (1/4”)
6,35 (1/4”)
6,35 (1/4”)
Gas
inch
9,52 (3/8”)
9,52 (3/8”)
9,52 (3/8”)
12,7 (1/2”)
Drainage
mm
25
25
25
25
Dimensions LxWxH
mm
Unit weight
kg
570(647)x570(647)x260(50)
16(2,5)
16(2,5)
16(2,5)
Wired controller
SYSCONTROL WC 90
(standard)
Duct indoor unit SYSPLIT DUCT EVO HP Q
Model indoor unit
18(2,5)
SYSPLIT DUCT
Art. no. Indoor unit
07 EVO HP Q
09 EVO HP Q
12 EVO HP Q
M 18 EVO HP Q
314024
314025
314026
314172
Cooling capacity
kW
2,02
2,60
3,47
5,20
Heating capacity
kW
2,31
2,89
3,76
5,78
Power consumption
W
30
30
40
107
Operating current
A
0,13
0,13
0,17
0,48
m3/h
600
600
680
1.000
Pa
40
40
40
70
dB(A)
38
38
40
42
Air flow rate (H/M/L)
External static pressure (H)
Sound pressure level (H)
Piping diameters
Dimensions LxWxH
Unit weight
Liquid
inch
6,35 (1/4”)
6,35 (1/4”)
6,35 (1/4”)
6,35 (1/4”)
Gas
inch
9,52 (3/8”)
9,52 (3/8”)
9,52 (3/8”)
12,7 (1/2”)
Drainage
mm
25
25
25
25
mm
700x635x210
700x635x210
700x635x210
920x635x210
19,5
19,5
18
23
kg
Multi-split combination |
Combination table SYSPLIT MULTI EVO
SYSPLIT MULTI2 14 EVO HP Q
One Unit
Two Unit
7
7+7
9
7+9
12
7+12
18
9+9
9+12
SYSPLIT MULTI2 18 EVO HP Q
One Unit
Two Unit
7
7+7
9
7+9
12
7+12
18
7+18
9+9
9+12
9+18
12+12
SYSPLIT MULTI3 21 EVO HP Q
One Unit
Two Unit
Three Unit
7
7+7
7+7+7
9
7+9
7+7+9
12
7+12
7+7+12
18
7+18
7+9+9
9+9
7+9+12
9+12
9+9+9
9+18
9+9+12
12+12
SYSPLIT MULTI4 28 EVO HP Q
One Unit
Two Unit
Three Unit
Four Unit
7
7+7
7+7+7
7+7+7+7
9
7+9
7+7+9
7+7+7+9
12
7+12
7+7+12
7+7+7+12
18
7+18
7+9+9
7+7+7+18
9+9
7+9+12
7+7+9+9
9+12
7+9+18
7+7+9+12
7+7+12+12
9+18
7+7+18
12+12
9+9+9
7+9+9+9
12+18
9+9+12
7+9+9+12
18+18
7+12+18
9+9+9+9
9+9+18
7+9+12+12
12+12+12
9+9+9+12
9+12+12
7+12+12
* In case combination of indoor units exceeds the nominal capacity of outdoor unit the capacity of each indoor units is smaller.
23
24
| Multi-split combination
Combination table SYSPLIT MULTI EVO
SYSPLIT MULTI5 36 EVO HP Q
One Unit
Two Unit
Three Unit
Four Unit
Five Unit
7
7+7
7+7+7
7+7+7+7
7+7+7+7+7
9
7+9
7+7+9
7+7+7+9
7+7+7+7+9
12
7+12
7+7+12
7+7+7+12
7+7+7+7+12
18
7+18
7+7+18
7+7+7+18
7+7+7+7+18
9+9
7+9+9
7+7+9+9
7+7+7+9+9
9+12
7+9+12
7+7+9+12
7+7+7+9+12
7+7+7+12+12
9+18
7+9+18
7+7+9+18
12+12
7+12+12
7+7+12+12
7+7+9+9+9
12+18
7+12+18
7+7+12+18
7+7+9+9+12
18+18
7+18+18
7+9+9+9
7+9+9+9+9
9+9+9
7+9+9+12
7+9+9+9+12
9+9+12
7+9+9+18
9+9+9+9+9
9+9+18
7+9+12+12
9+9+9+9+12
9+12+12
7+9+12+18
9+9+9+9+18
9+12+18
7+12+12+12
9+9+9+12+12
12+12+12
9+9+9+9
9+9+9+12+18
12+12+18
9+9+9+12
9+9+12+12+12
12+18+18
9+9+9+18
9+12+12+12+12
18+18+18
9+9+12+12
12+12+12+12+12
9+12+12+12
9+12+12+18
12+12+12+12
12+12+12+18
SYSPLIT MULTI5 42 EVO HP Q
One Unit
Two Unit
7
7+7
7+7+7
Three Unit
9+9+18
7+7+7+7
Four Unit
7+9+12+24
7+7+7+7+7
Five Unit
7+7+9+18+18
9
7+9
7+7+9
9+9+24
7+7+7+9
7+9+18+18
7+7+7+7+9
7+7+12+12+12
7+7+12+12+18
12
7+12
7+7+12
9+12+12
7+7+7+12
7+9+18+24
7+7+7+7+12
18
7+18
7+7+18
7+12+12
7+7+7+18
7+12+12+12
7+7+7+7+18
7+9+9+9+9
24
7+24
7+7+24
9+12+18
7+7+7+24
7+12+12+18
7+7+7+7+24
7+9+9+9+12
9+9
7+9+9
9+12+24
7+7+9+9
7+12+12+24
7+7+7+9+9
7+9+9+9+18
9+12
7+9+12
9+18+18
7+7+9+12
7+12+18+18
7+7+7+9+12
7+9+9+9+24
9+18
7+9+18
12+12+12
7+7+9+18
9+9+9+9
7+7+7+9+18
7+9+9+12+12
9+24
7+9+24
12+12+18
7+7+9+24
9+9+9+12
7+7+7+9+24
7+9+9+12+18
12+12
7+12+12
12+12+24
7+7+12+12
9+9+9+18
7+7+7+12+12
7+9+12+12+12
12+18
7+12+18
12+18+18
7+7+12+18
9+9+9+24
7+7+7+12+18
7+9+12+12+18
7+12+12+12+12
12+24
7+12+24
12+18+24
7+7+12+24
9+9+12+12
7+7+7+12+24
18+18
7+18+18
18+18+18
7+7+18+18
9+9+12+18
7+7+7+18+18
9+9+9+9+9
18+24
9+9+9
18+18+18
7+7+18+24
9+9+12+24
7+7+9+9+9
9+9+9+9+12
24+24
9+9+12
7+9+9+9
9+9+18+18
7+7+9+9+12
9+9+9+9+18
7+9+9+12
9+12+12+12
7+7+9+9+18
9+9+9+12+12
7+9+9+18
9+12+12+18
7+7+9+9+24
9+9+9+12+18
7+9+9+24
9+12+12+24
7+7+9+12+12
9+9+12+12+12
7+9+12+12
9+12+18+18
7+7+9+12+18
9+12+12+12+12
7+9+12+18
12+12+12+12
12+12+12+18
* In case combination of indoor units exceeds the nominal capacity of outdoor unit the capacity of each indoor units is smaller.
Multi-split combination |
Rated capacity table SYSPLIT MULTI EVO
SYSPLIT MULTI2 14 EVO HP Q
COOLING
Comb.
1:2
Combinations
Rated Capacity (kW)
Total Cooling Capacity (kW)
Unit A
Unit B
Unit A
Unit B
min. data
rated data
max. data
7
7
2,05
2,05
2,87
4,10
5,13
7
9
2,00
2,50
3,15
4,50
5,31
7
12
1,95
3,00
3,47
4,95
5,35
9
9
2,45
2,45
3,43
4,90
5,35
9
12
2,40
2,95
3,75
5,35
5,35
HEATING
Comb.
1:2
Combinations
Rated Capacity (kW)
Total Cooling Capacity (kW)
Unit A
Unit B
Unit A
Unit B
min. data
rated data
max. data
7
7
2,35
2,35
3,29
4,70
5,41
7
9
2,25
2,75
3,50
5,00
5,50
7
12
2,15
3,25
3,78
5,40
5,70
9
9
2,60
2,60
3,64
5,20
5,70
9
12
2,50
3,20
3,99
5,70
5,70
SYSPLIT MULTI2 18 EVO HP Q
COOLING
Comb.
1:2
Combinations
Rated Capacity (kW)
Total Cooling Capacity (kW)
Unit A
Unit B
Unit A
Unit B
min. data
rated data
max. data
7
7
2,10
2,10
2,94
4,20
5,46
7
9
2,10
2,50
3,22
4,60
5,98
7
12
2,10
3,50
3,92
5,60
6,70
7
18
1,90
4,75
4,66
6,65
6,70
9
9
2,64
2,64
3,70
5,28
6,70
9
12
2,50
3,50
4,20
6,00
6,70
9
18
2,10
4,60
4,69
6,70
6,70
12
12
3,30
3,30
4,62
6,60
6,70
HEATING
Comb.
1:2
Combinations
Rated Capacity (kW)
Total Heating Capacity (kW)
Unit A
Unit B
Unit A
Unit B
min. data
rated data
max. data
7
7
2,40
2,40
3,36
4,80
6,24
7
9
2,35
2,95
3,71
5,30
6,89
7
12
2,25
3,70
4,17
5,95
7,20
7
18
2,10
5,05
5,01
7,15
7,20
9
9
3,08
3,08
4,31
6,16
7,20
9
12
2,80
3,60
4,48
6,40
7,20
9
18
2,45
4,75
5,04
7,20
7,20
12
12
3,45
3,45
4,83
6,90
7,20
25
26
| Multi-split combination
Rated capacity table SYSPLIT MULTI EVO
SYSPLIT MULTI3 21 EVO HP Q
COOLING
Comb.
1:3
Combinations
Rated Capacity (kW)
Total Cooling Capacity (kW)
Unit A
Unit B
Unit C
Unit A
Unit B
Unit C
min. data
rated data
7
7
7
2,05
2,05
2,05
4,00
6,15
max. data
7,07
7
7
9
1,95
1,95
2,54
4,19
6,45
7,22
7
7
12
1,93
1,93
3,09
4,52
6,95
7,51
7
9
9
1,89
2,46
2,46
4,42
6,80
7,48
7
9
12
1,86
2,42
2,97
4,71
7,25
7,60
9
9
9
2,37
2,37
2,37
4,62
7,10
7,60
9
9
12
2,35
2,35
2,90
4,94
7,60
7,60
HEATING
Comb.
1:3
Combinations
Rated Capacity (kW)
Total Cooling Capacity (kW)
Unit A
Unit B
Unit C
Unit A
Unit B
Unit C
min. data
rated data
7
7
7
2,25
2,25
2,25
4,38
6,74
max. data
7,55
7
7
9
2,12
2,12
2,76
4,55
7,00
7,70
7
7
12
2,05
2,05
3,28
4,80
7,38
7,86
7
9
9
2,01
2,62
2,62
4,71
7,25
7,83
7
9
12
1,96
2,55
3,13
4,97
7,64
7,90
9
9
9
2,51
2,51
2,51
4,89
7,52
7,90
9
9
12
2,45
2,45
3,01
5,14
7,90
7,90
Multi-split combination |
SYSPLIT MULTI4 28 EVO HP Q
COOLING
Comb.
1:4
Combinations
Rated Capacity (kW)
Total Cooling Capacity (kW)
Unit A
Unit B
Unit C
Unit D
Unit A
Unit B
Unit C
Unit D
min. data
rated data
max. data
7
7
7
7
2,05
2,05
2,05
2,05
5,34
8,21
9,20
7
7
7
9
1,98
1,98
1,98
2,57
5,53
8,50
9,35
7
7
7
12
1,94
1,94
1,94
3,10
5,80
8,92
9,72
7
7
7
18
1,73
1,73
1,73
4,60
6,37
9,80
9,94
7
7
9
9
1,91
1,91
2,49
2,49
5,72
8,80
9,68
7
7
9
12
1,88
1,88
2,45
3,01
5,99
9,22
9,87
7
7
12
12
1,86
1,86
2,97
2,97
6,27
9,65
9,94
7
9
9
9
1,85
2,41
2,41
2,41
5,90
9,08
9,81
7
9
9
12
1,83
2,38
2,38
2,93
6,18
9,51
9,94
7
9
12
12
1,81
2,35
2,89
2,89
6,46
9,94
9,94
9
9
9
9
2,34
2,34
2,34
2,34
6,07
9,34
9,94
9
9
9
12
2,32
2,32
2,32
2,85
6,37
9,80
9,94
HEATING
Comb.
1:4
Combinations
Rated Capacity (kW)
Total Cooling Capacity (kW)
Unit A
Unit B
Unit C
Unit D
Unit A
Unit B
Unit C
Unit D
min. data
rated data
max. data
7
7
7
7
2,27
2,27
2,27
2,27
6,36
9,09
10,00
7
7
7
9
2,17
2,17
2,17
2,82
6,54
9,34
10,18
7
7
7
12
2,11
2,11
2,11
3,38
6,80
9,72
10,50
7
7
7
18
1,85
1,85
1,85
4,91
7,33
10,47
10,60
7
7
9
9
2,09
2,09
2,71
2,71
6,72
9,60
10,46
7
7
9
12
2,04
2,04
2,65
3,26
6,99
9,98
10,58
7
7
12
12
1,99
1,99
3,18
3,18
7,25
10,35
10,60
7
9
9
9
2,01
2,61
2,61
2,61
6,90
9,85
10,54
7
9
9
12
1,96
2,55
2,55
3,14
7,14
10,20
10,60
7
9
12
12
1,93
2,51
3,08
3,08
7,42
10,60
10,60
9
9
9
9
2,53
2,53
2,53
2,53
7,07
10,10
10,60
9
9
9
12
2,47
2,47
2,47
3,05
7,33
10,47
10,60
27
28
| Multi-split combination
Rated capacity table SYSPLIT MULTI EVO
SYSPLIT MULTI5 36 EVO HP Q
COOLING
Comb.
1:5
Combinations
Rated Capacity (kW)
Total Cooling Capacity (kW)
Unit A
Unit B
Unit C
Unit D
Unit E
Unit A
Unit B
Unit C
Unit D
Unit E
7
7
7
7
7
2,11
2,11
2,11
2,11
2,11
min.
data
6,86
10,55
max.
data
12,45
7
7
7
7
9
2,05
2,05
2,05
2,05
2,66
7,05
10,85
12,80
7
7
7
7
12
2,02
2,02
2,02
2,02
3,23
7,35
11,31
13,23
7
7
7
7
18
1,84
1,84
1,84
1,84
4,87
7,95
12,23
13,94
7
7
7
9
9
1,99
1,99
1,99
2,59
2,59
7,25
11,16
13,06
7
7
7
9
12
1,97
1,97
1,97
2,56
3,15
7,55
11,62
13,36
7
7
7
9
18
1,80
1,80
1,80
2,34
4,78
8,14
12,53
14,03
7
7
7
12
12
1,95
1,95
1,95
3,12
3,12
7,85
12,08
13,53
7
7
7
12
18
1,79
1,79
1,79
2,87
4,75
8,44
12,99
14,36
7
7
7
18
18
1,67
1,67
1,67
4,44
4,44
9,04
13,90
14,36
7
7
9
9
9
1,94
1,94
2,53
2,53
2,53
7,45
11,46
13,29
7
7
9
9
12
1,92
1,92
2,50
2,50
3,08
7,75
11,92
13,71
7
7
9
12
12
1,90
1,90
2,48
3,05
3,05
8,05
12,38
13,87
7
7
9
12
18
1,76
1,76
2,29
2,82
4,66
8,64
13,29
14,36
7
7
12
12
12
1,89
1,89
3,02
3,02
3,02
8,35
12,84
14,25
7
7
12
12
18
1,75
1,75
2,80
2,80
4,64
8,94
13,75
14,36
7
9
9
9
9
1,90
2,47
2,47
2,47
2,47
7,65
11,77
13,42
7
9
9
9
12
1,88
2,45
2,45
2,45
3,01
7,95
12,23
13,94
7
9
9
9
18
1,74
2,26
2,26
2,26
4,61
8,54
13,14
14,36
7
9
9
12
12
1,86
2,42
2,42
2,98
2,98
8,24
12,68
14,20
7
9
9
12
18
1,73
2,25
2,25
2,77
4,59
8,84
13,60
14,36
7
9
12
12
12
1,85
2,41
2,96
2,96
2,96
8,54
13,14
14,36
7
9
12
12
18
1,72
2,24
2,76
2,76
4,57
9,13
14,05
14,36
9
9
9
9
9
2,42
2,42
2,42
2,42
2,42
7,85
12,08
13,77
9
9
9
9
12
2,40
2,40
2,40
2,40
2,95
8,14
12,53
14,03
9
9
9
9
18
2,23
2,23
2,23
2,23
4,54
8,74
13,45
14,36
9
9
9
12
12
2,38
2,38
2,38
2,93
2,93
8,44
12,99
14,36
9
9
9
12
18
2,22
2,22
2,22
2,73
4,52
9,04
13,90
14,36
9
9
12
12
12
2,36
2,36
2,91
2,91
2,91
8,74
13,45
14,36
9
12
12
12
12
2,35
2,89
2,89
2,89
2,89
9,04
13,90
14,36
12
12
12
12
12
2,87
2,87
2,87
2,87
2,87
9,33
14,36
14,36
rated data
Multi-split combination |
HEATING
Comb.
1:5
Combinations
Rated Capacity (kW)
Total Cooling Capacity (kW)
Unit A
Unit B
Unit C
Unit D
Unit E
Unit A
Unit B
Unit C
Unit D
Unit E
7
7
7
7
7
2,46
2,46
2,46
2,46
2,46
min.
data
8,00
12,31
max.
data
14,16
7
7
7
7
9
2,37
2,37
2,37
2,37
3,08
8,16
12,56
14,19
7
7
7
7
12
2,31
2,31
2,31
2,31
3,69
8,40
12,93
14,35
7
7
7
7
18
2,06
2,06
2,06
2,06
5,45
8,89
13,67
14,76
7
7
7
9
9
2,29
2,29
2,29
2,97
2,97
8,32
12,80
14,27
7
7
7
9
12
2,23
2,23
2,23
2,90
3,57
8,57
13,18
14,43
7
7
7
9
18
2,00
2,00
2,00
2,60
5,31
9,05
13,92
15,03
7
7
7
12
12
2,19
2,19
2,19
3,50
3,50
8,81
13,55
14,63
7
7
7
12
18
1,97
1,97
1,97
3,15
5,22
9,29
14,29
15,40
7
7
7
18
18
1,81
1,81
1,81
4,80
4,80
9,77
15,03
15,40
7
7
9
9
9
2,21
2,21
2,88
2,88
2,88
8,48
13,05
14,36
7
7
9
9
12
2,16
2,16
2,81
2,81
3,46
8,72
13,42
14,56
7
7
9
12
12
2,12
2,12
2,76
3,40
3,40
8,97
13,80
14,90
7
7
9
12
18
1,92
1,92
2,50
3,08
5,10
9,44
14,53
15,40
7
7
12
12
12
2,08
2,08
3,33
3,33
3,33
9,20
14,16
15,29
7
7
12
12
18
1,90
1,90
3,04
3,04
5,03
9,69
14,90
15,40
7
9
9
9
9
2,15
2,79
2,79
2,79
2,79
8,65
13,30
14,50
7
9
9
9
12
2,10
2,73
2,73
2,73
3,36
8,89
13,67
14,76
7
9
9
9
18
1,91
2,48
2,48
2,48
5,06
9,37
14,41
15,40
7
9
9
12
12
2,06
2,68
2,68
3,30
3,30
9,13
14,04
15,16
7
9
9
12
18
1,88
2,45
2,45
3,01
4,99
9,61
14,78
15,40
7
9
12
12
12
2,03
2,64
3,25
3,25
3,25
9,37
14,41
15,40
7
9
12
12
18
1,86
2,42
2,97
2,97
4,93
9,85
15,15
15,40
9
9
9
9
9
2,71
2,71
2,71
2,71
2,71
8,81
13,55
14,63
9
9
9
9
12
2,66
2,66
2,66
2,66
3,28
9,05
13,92
15,03
9
9
9
9
18
2,43
2,43
2,43
2,43
4,95
9,53
14,66
15,40
9
9
9
12
12
2,62
2,62
2,62
3,22
3,22
9,29
14,29
15,40
9
9
9
12
18
2,40
2,40
2,40
2,95
4,89
9,77
15,03
15,40
9
9
12
12
12
2,58
2,58
3,17
3,17
3,17
9,53
14,66
15,40
9
12
12
12
12
2,54
3,12
3,12
3,12
3,12
9,77
15,03
15,40
12
12
12
12
12
3,08
3,08
3,08
3,08
3,08
10,01
15,40
15,40
rated data
29
30
| Multi-split combination
Rated capacity table SYSPLIT MULTI EVO
SYSPLIT MULTI5 42 EVO HP Q
COOLING
Comb.
1:5
Combinations
Rated Capacity (kW)
Total Cooling Capacity (kW)
Unit A
Unit B
Unit C
Unit D
Unit E
Unit A
Unit B
Unit C
Unit D
Unit E
7
7
7
7
7
2,11
2,11
2,11
2,11
2,11
min.
data
4,43
10,55
max.
data
11,61
7
7
7
7
9
2,07
2,07
2,07
2,07
2,69
4,61
10,97
14,26
7
7
7
7
12
2,02
2,02
2,02
2,02
3,23
4,75
11,31
14,29
7
7
7
7
18
1,88
1,88
1,88
1,88
4,97
5,24
12,48
14,42
7
7
7
7
24
1,79
1,79
1,79
1,79
6,26
5,64
13,42
14,52
7
7
7
9
9
2,02
2,02
2,02
2,62
2,62
4,75
11,31
14,29
7
7
7
9
12
1,97
1,97
1,97
2,56
3,15
4,87
11,61
13,28
7
7
7
9
18
1,84
1,84
1,84
2,40
4,88
5,38
12,81
14,45
7
7
7
9
24
1,76
1,76
1,76
2,29
6,17
5,78
13,76
14,55
7
7
7
12
12
1,93
1,93
1,93
3,09
3,09
5,02
11,96
13,84
7
7
7
12
18
1,81
1,81
1,81
2,90
4,80
5,52
13,15
14,49
7
7
7
12
24
1,74
1,74
1,74
2,78
6,09
5,92
14,09
14,59
7
7
7
18
18
1,72
1,72
1,72
4,57
4,57
6,01
14,32
14,61
7
7
9
9
9
1,97
1,97
2,57
2,57
2,57
4,89
11,64
14,33
7
7
9
9
12
1,93
1,93
2,51
2,51
3,09
5,03
11,98
14,36
7
7
9
9
18
1,81
1,81
2,36
2,36
4,80
5,52
13,15
14,49
7
7
9
9
24
1,74
1,74
2,26
2,26
6,09
5,92
14,09
14,59
7
7
9
12
12
1,89
1,89
2,46
3,03
3,03
5,17
12,31
14,40
7
7
9
12
18
1,79
1,79
2,32
2,86
4,73
5,66
13,48
14,53
7
7
9
18
18
1,70
1,70
2,21
4,51
4,51
6,15
14,65
14,65
7
7
12
12
12
1,86
1,86
2,98
2,98
2,98
5,31
12,64
14,44
7
7
12
12
18
1,76
1,76
2,82
2,82
4,66
5,80
13,81
14,56
7
9
9
9
9
1,93
2,51
2,51
2,51
2,51
5,03
11,98
14,36
7
9
9
9
12
1,89
2,46
2,46
2,46
3,03
5,17
12,31
14,40
7
9
9
9
18
1,79
2,32
2,32
2,32
4,73
5,66
13,48
14,53
7
9
9
9
24
1,72
2,23
2,23
2,23
6,01
6,06
14,43
14,63
7
9
9
12
12
1,86
2,42
2,42
2,98
2,98
5,31
12,64
14,44
7
9
9
12
18
1,76
2,29
2,29
2,82
4,66
5,80
13,81
14,56
7
9
12
12
12
1,83
2,38
2,92
2,92
2,92
5,45
12,98
14,47
7
9
12
12
18
1,74
2,26
2,78
2,78
4,60
5,94
14,15
14,60
7
12
12
12
12
1,80
2,88
2,88
2,88
2,88
5,59
13,31
14,51
9
9
9
9
9
2,46
2,46
2,46
2,46
2,46
5,17
12,31
14,40
9
9
9
9
12
2,42
2,42
2,42
2,42
2,98
5,31
12,64
14,44
9
9
9
9
18
2,29
2,29
2,29
2,29
4,66
5,80
13,81
14,56
9
9
9
12
12
2,38
2,38
2,38
2,92
2,92
5,45
12,98
14,47
9
9
9
12
18
2,26
2,26
2,26
2,78
4,60
5,94
14,15
14,60
9
9
12
12
12
2,34
2,34
2,88
2,88
2,88
5,59
13,31
14,51
9
12
12
12
12
2,30
2,84
2,84
2,84
2,84
5,73
13,65
14,54
rated data
Multi-split combination |
HEATING
Comb.
1:5
Combinations
Rated Capacity (kW)
Total Cooling Capacity (kW)
Unit A
Unit B
Unit C
Unit D
Unit E
Unit A
Unit B
Unit C
Unit D
Unit E
7
7
7
7
7
2,17
2,17
2,17
2,17
2,17
min.
data
4,55
10,84
max.
data
11,87
7
7
7
7
9
2,10
2,10
2,10
2,10
2,73
4,68
11,14
12,58
7
7
7
7
12
2,04
2,04
2,04
2,04
3,27
4,80
11,43
13,28
7
7
7
7
18
1,89
1,89
1,89
1,89
5,00
5,27
12,54
15,41
7
7
7
7
24
1,85
1,85
1,85
1,85
6,46
5,81
13,84
15,46
7
7
7
9
9
2,04
2,04
2,04
2,65
2,65
4,80
11,43
13,28
7
7
7
9
12
1,99
1,99
1,99
2,58
3,18
4,92
11,72
13,99
7
7
7
9
18
1,87
1,87
1,87
2,43
4,96
5,46
13,00
15,43
7
7
7
9
24
1,83
1,83
1,83
2,38
6,42
6,01
14,30
15,48
7
7
7
12
12
1,94
1,94
1,94
3,10
3,10
5,05
12,02
14,69
7
7
7
12
18
1,86
1,86
1,86
2,97
4,92
5,65
13,46
15,45
7
7
7
12
24
1,82
1,82
1,82
2,92
6,38
6,20
14,76
15,50
7
7
7
18
18
1,82
1,82
1,82
4,81
4,81
6,33
15,07
15,51
7
7
9
9
9
1,99
1,99
2,58
2,58
2,58
4,92
11,72
13,99
7
7
9
9
12
1,94
1,94
2,52
2,52
3,10
5,05
12,02
14,69
7
7
9
9
18
1,86
1,86
2,41
2,41
4,92
5,65
13,46
15,45
7
7
9
9
24
1,82
1,82
2,37
2,37
6,38
6,20
14,76
15,50
7
7
9
12
12
1,89
1,89
2,46
3,03
3,03
5,17
12,31
15,40
7
7
9
12
18
1,84
1,84
2,40
2,95
4,89
5,85
13,92
15,47
7
7
9
18
18
1,81
1,81
2,35
4,79
4,79
6,52
15,53
15,53
7
7
12
12
12
1,88
1,88
3,00
3,00
3,00
5,36
12,77
15,42
7
7
12
12
18
1,83
1,83
2,93
2,93
4,85
6,04
14,38
15,48
7
9
9
9
9
1,94
2,52
2,52
2,52
2,52
5,05
12,02
14,69
7
9
9
9
12
1,89
2,46
2,46
2,46
3,03
5,17
12,31
15,40
7
9
9
9
18
1,84
2,40
2,40
2,40
4,89
5,85
13,92
15,47
7
9
9
9
24
1,81
2,36
2,36
2,36
6,34
6,39
15,22
15,52
7
9
9
12
12
1,88
2,44
2,44
3,00
3,00
5,36
12,77
15,42
7
9
9
12
18
1,83
2,38
2,38
2,93
4,85
6,04
14,38
15,48
7
9
12
12
12
1,86
2,42
2,98
2,98
2,98
5,56
13,23
15,44
7
9
12
12
18
1,82
2,37
2,91
2,91
4,83
6,23
14,84
15,50
7
12
12
12
12
1,85
2,96
2,96
2,96
2,96
5,75
13,69
15,46
9
9
9
9
9
2,46
2,46
2,46
2,46
2,46
5,17
12,31
15,40
9
9
9
9
12
2,44
2,44
2,44
2,44
3,00
5,36
12,77
15,42
9
9
9
9
18
2,38
2,38
2,38
2,38
4,85
6,04
14,38
15,48
9
9
9
12
12
2,42
2,42
2,42
2,98
2,98
5,56
13,23
15,44
9
9
9
12
18
2,37
2,37
2,37
2,91
4,83
6,23
14,84
15,50
9
9
12
12
12
2,41
2,41
2,96
2,96
2,96
5,75
13,69
15,46
9
12
12
12
12
2,39
2,94
2,94
2,94
2,94
5,94
14,15
15,47
rated data
31
| Cassette Inverter High efficiency Split
Cassette Inverter High efficiency Split
SYSPLIT CASSETTE EVO HP
Features
SYSPLIT CASSETTE EVO air conditioners are ideal solution
for creating a comfortable climate in the office and
shopping centers – in all rooms designed with false ceilings.
Dimensions
SYSPLIT CASSETTE
size 12-18
840 (Body)
Infrared remote controller SYSCONTROL RM 52 included;
Wired remote SYSCONTROL WC 90 available as accessory.
A
A
SYSPLIT OUTDOOR
size 12 to 24
24 to 60
size 36 to 60
A
H H
E E
C C
D D
647(Panel)
F F
570(Body)
A
Model
A
Hook
50
Ceiling
600
Outlet
Inlet
Outlet
B
Panel
B
12
18
24
36
48
60
760
845
900
938
938
938
530
560
634
634
634
335
333
404
404
404
590
C
290
E
C
D
Nut
B
A
D
315
360
355
448
448
448
368
F
H
A
Body
H
A
A
BB
BB
780 (Hook-location)
840 (Body)
950 (Panel)
545(Hook-location)
H
840 (Body)
950 (Panel)
680 (Hook-location)
570(Body)
647(Panel)
523(Hook-location)
H H
780 (Hook-location)
840 (Body)
size
950 (Panel)
Wired
controller
SYSCONTROL
WC 90
Art. no. 314139
(optional)
Infrared remote
control
SYSCONTROL
RM 52
(standard)
950 (Panel)
680 (Hook-location)
Advanced DC inverter control for the compressor,
outdoor fan motor and indoor fan motor.
Available with 2 different sizes: 57x57 for models 12
and 18, 84x84 for models 24 to 60.
The 360° round flow panel assures an optimal air
distribution and comfort in the room.
Special aerodynamic shape of the fan and the geometry
of the blades ensure low noise from the air conditioner.
Washable air filter included in the panel greatly
simplifies the maintenance.
The panel is equipped with an interactive LCD.
Built-in drain pump with lift height up to 500 mm for
models 12-18, and up to 750 mm for models 24 to 60.
Fresh air intake can fufill air quality requirements and
enhance occupants comfort.
Auto-restart after electric power failure.
Environment friendly refrigerant R410A.
260mm
>2500
Model
12
18
24
36
48
60
E
270
312
302
368
368
A
260
260
245
245
287
287
F
285
320
315
392
392
392
H
>280
>280
>260
>260
>330
>330
H
590
700
860
1.369
1.369
1.369
>2500 mm
A
H
32
Outlet
Inlet
Outlet
Cassette Inverter High efficiency Split |
Technical features
Model Indoor unit
SYSPLIT CASSETTE
12 EVO
HP Q
18 EVO
HP Q
24 EVO
HP Q
36 EVO
HP Q
36 EVO
HP Q
48 EVO
HP Q
60 EVO
HP Q
Model Outdoor unit
SYSPLIT OUTDOOR
12 EVO
HP Q
18 EVO
HP Q
24 EVO
HP Q
36 EVO
HP Q
36 EVO
HP R
48 EVO
HP R
60 EVO
HP R
CASSETTE
MINI SPLIT
CASSETTE
MINI SPLIT
CASSETTE
EVO SPLIT
CASSETTE
EVO SPLIT
CASSETTE
EVO SPLIT
CASSETTE
EVO SPLIT
CASSETTE
EVO SPLIT
Model Panel unit
SYSPANEL
Art. no. Indoor unit
314028
314029
314030
314031
314031
314033
314035
Art. no. Outdoor unit
314056
314057
314058
314059
314060
314062
314063
314034
314034
314034
Art. no. Panel
314032
314032
314034
R410A / 1,1
R410A / 1,8
R410A / 2,2
kW
3,52
(1,11-4,53)
5,28
(1,29-7,37)
7,04
(1,46-8,77)
10,54
10,56
14,06
16,11
(2,86-12,28) (2,86-13,15) (4,33-15,49) (4,82-17,68)
Power consumption
W
1.090
(180-1.780)
1.640
(230-2.460)
2.100
(280-3.450)
3.100
(620-5.300)
Operating current
A
4.7
(0.8-7.9)
7,1
(1.0-10.7)
9.1
(1.2-15.0)
13.5
(2.8-23.6)
5.5
(1.1-9.1)
7.6
(2.2-10.9)
8.7
(2.5-12.4)
Refrigerant / Charged quantity
Power supply
kg
V/Ph/Hz
Cooling capacity
R410A / 4,3 R410A / 4,35 R410A / 3,8
220-240/1/50
314034
R410A / 4,6
380-420/3/50
3.200
4.380
5.020
(620-5.300) (1.200-6.010) (1.350-6.820)
EER
3,23
3,22
3,35
3,40
3,30
3,21
3,21
SEER
5,6
5,6
6,5
6,0
5,6
-
-
Energy label cooling
A+
A+
A++
A+
A+
-
-
kW
4,10
(0,99-4,68)
5,86
(1,08-7,37)
7,61
(1,32-9,41)
11,73
11,74
16,40
19,06
(3,80-13,15) (3,80-14,03) (4,91-18,27) (5,70-20,90)
Power consumption
W
1.070
(180-1.620)
1.580
(230-2.380)
2.030
(280-3.420)
3.250
(780-5.000)
Operating current
A
4.6
(0.8-7.0)
6.9
(1.0-10.3)
8.8
(1.2-14.9)
14.1
(3.5-22.2)
5.4
(1.3-8.6)
7.6
(2.1-10.7)
9,1
(2.5-12.7)
COP
3,83
3,71
3,75
3,61
3,75
3,71
3,61
SCOP (Average)
3,8
3,8
3,8
3,8
3,8
-
-
A
A
A
A
A
-
-
Heating capacity
Energy label heating
3.130
4.420
5.280
(780-5.000) (1.170-5.910) (1.390-6.980)
Indoor Unit
Air flow rate (H/M/L)
m3/h
1580/1.200
/1.000
800/710/560
1.950/1.650/1.400
2.250/1.850/1.650
Sound pressure level (H)
dB(A)
37
42
45
48
48
50
50
Sound power level (H)
dB(A)
54
59
62
65
65
67
67
Dimensions (Panel) LxWxH
mm
570(647)x570(647)
x260(50)
840(950)x840(950)x245(55)
840(950)x840(950)
x287(55)
Packing (Panel) LxWxH
mm
655(715)x655(715)
x290(123)
900(1.035)x900(1.035)x265(90)
900(1.035)x900(1.035)
x292(90)
Net/gross (Panel) weight
kg
16(2,5)/
19(4,5)
18(2,5)/
21(4,5)
24(5)/
28(8)
26,5(5)/30,5(8)
29(5)/33(8)
31(5)/34(8)
Twin-rotary
Outdoor Unit
Type
Rotary
Rotary
Twin-rotary
Twin-rotary
Twin-rotary
Twin-rotary
Sound pressure level (H)
Compressor
dB(A)
44
48
52
52
52
52
53
Sound power level (H)
dB(A)
61
65
69
69
69
69
70
Dimensions LxWxH
mm
760x285
x590
845x320
x700
900x315
x860
938x392x1.369
Packing LxWxH
mm
887x355
x645
965x395
x755
1.043x395
x915
1.095x495x1.505
Net/gross weight
Piping diameters
35,4/37,9
46/50
59/63
100/114
102/116
102/118
107/120
Liquid
inch
kg
6,35 (1/4”)
6,35 (1/4”)
9,52 (3/8”)
9,52 (3/8”)
9,52 (3/8”)
9,52 (3/8”)
9,52 (3/8”)
Gas
inch
9,52 (3/8”)
12,7 (1/2”)
15,9 (5/8”)
15,9 (5/8”)
15,9 (5/8”)
15,9 (5/8”)
15,9 (5/8”)
Drainage
mm
25
25
32
32
32
32
32
A
9,5
10
13
25
11
13
15
Max. input current
Maximum lenght of the line
m
20
30
50
65
65
65
65
Maximum height difference
m
10
20
25
30
30
30
30
Outdoor temperature
°C
-15 ... +50 cooling / heating -15 ... +24
Nominal conditions
Indoor unit
Outdoor unit
Piping lenght
Level difference
Cooling mode
27°C DB, 19°C WB
35°C DB
5m
0m
Heating mode
20°C DB, 19°C WB
7°C DB, 6°C WB
5m
0m
Seasonal efficiency according to EN 14825. Seasonal efficiency and energy labelling is not applicable to split systems with cooling capacity exceeding 12 kW.
The sound pressure value may vary depending on ambient conditions.
33
| Ceiling/Floor Inverter High efficiency Split
Ceiling/Floor Inverter High efficiency Split
SYSPLIT CEILING EVO HP
Features
SYSPLIT CEILING EVO air conditioners are perfectly combined
with any interior and are stylish with modern design.
Advanced DC inverter control for the compressor,
outdoor fan motor and indoor fan motor.
Flexible installation, the unit can be installed hanged on
the wall or ceiling suspended.
High efficient and washable air filter included.
Automatic distribution of the treated air in the horizontal
and vertical directions.
Compact, easy to install and maintain, can be even
installed in a corner.
Low noise level thanks to the improved shape of the
impeller blades.
The fresh air intake can fulfill air quality requirements
and enhance occupants comfort.
With the Auto-restart function the unit resume with
the same settings before the electric power failure.
Environment friendly R410A refrigerant.
A
Infrared remote controller SYSCONTROL RM 52 included;
Wired remote SYSCONTROL WC 90 available as accessory.
A
A
B
Dimensions
Wired
controller
SYSCONTROL
WC 90
Art. no. 314139
(optional)
Infrared remote
control
SYSCONTROL
RM 52
(standard)
SYSPLIT OUTDOOR
size 12 to 24
C
A
D
H H
A
size 36 to 60
H H
SYSPLIT CEILING
H
E
B
E E
C C
D D
D
A
24
36
48
60
Model
A
1.068
1.068
1.650
1.650
1.650
A
18
24
36
48
60
845
900
938
938
938
B
675
675
675
675
675
B
C
235
235
235
235
235
C
560
335
590
634
634
634
333
404
404
D
983
983
1.565
1.565
1.565
D
404
360
355
448
448
E
220
220
220
220
220
448
E
312
302
368
368
368
F
320
315
392
392
392
H
700
860
1.369
1.369
1.369
B
B
E
C
D
18
F
Model
F F
C
H
A
A
BB
BB
E
34
Ceiling/Floor Inverter High efficiency Split |
Technical features
Model Indoor unit
SYSPLIT CEILING
18 EVO HP Q
24 EVO HP Q
36 EVO HP Q
36 EVO HP Q
48 EVO HP Q
60 EVO HP Q
SYSPLIT OUTDOOR
18 EVO HP Q
24 EVO HP Q
36 EVO HP Q
36 EVO HP R
48 EVO HP R
60 EVO HP R
Art. no. Indoor unit
314042
314043
314044
314044
314046
314048
Art. no. Outdoor unit
314057
314058
314059
314060
314062
314063
R410A / 2,2
R410A / 4,3
R410A / 4,35
R410A / 3,8
R410A / 4,6
Model Outdoor unit
Refrigerant / Charged quantity
Power supply
kg
R410A / 1,8
V/Ph/Hz
220-240/1/50
380-420/3/50
380-420/3/50
kW
5,29
(1,29-7,37)
7,07
(1,46-8,77)
10,56
(2,92-13,15)
10,55
(2,92-13,15)
14,07
(4,33-15,55)
16,41
(4,91-17,98)
Power consumption
W
1.450
(230-2.460)
2.070
(280-3.450)
3.080
(600-5.280)
2.770
(600-5.280)
4.380
(1.200-6.000)
5.110
(1.370-6.930)
Operating current
A
6.3 (1.0-10.7)
Cooling capacity
4.8 (1.0-9.1)
7.6 (2.2-10.9)
8.8 (2.5-12.6)
EER
3,65
3,40
3,43
3,81
3,21
3,21
SEER
6,2
6,6
6,0
6,5
-
-
Energy label cooling
A++
A++
A+
A++
-
-
kW
5,85
(1,08-7,37)
7,6
(1,32-9,50)
11,71
(3,80-14,03)
11,72
(3,80-14,03)
16,40
(4,91-18,36)
19,05
(5,70-20,90)
Power consumption
W
1.410
(230-2.380)
1.900
(280-3.420)
3.140
(750-5.000)
2.930
(750-5.000)
4.420
(1.170-5.910)
5.280
(1.390-6.980)
Operating current
A
Heating capacity
9.0 (1.2-15.0) 13.04 (2.7-23.5)
6.1 (1.0-10.3)
8.3 (1.2-14.9)
13,7 (3.3-22.2)
5.1 (1.3-8.6)
7.6 (2.1-10.7)
9.1 (2.5-12.7)
COP
4,15
4,00
3,73
4,00
3,71
3,61
SCOP (Average)
3,8
3,8
3,8
3,8
-
-
A
A
A
A
-
-
900/
750/600
1.400/
1.250/1.100
Energy label heating
Indoor Unit
Air flow rate (H/M/L)
m3/h
2.200/1.850/1.500
2.300/1.900/1.700
Sound pressure level (H)
dB(A)
43
46
47
48
50
50
Sound power level (H)
dB(A)
60
63
64
65
67
67
Dimensions LxWxH
mm
1.068x675x235
Packing LxWxH
mm
1.145x755x313
Net/gross weight
kg
1.650x675x235
1.725x755x313
25/31,5
25/30
40/46
40/46
40/46
40/46
Twin-rotary
Outdoor Unit
Type
Rotary
Twin-rotary
Twin-rotary
Twin-rotary
Twin-rotary
Sound pressure level (H)
Compressor
dB(A)
48
52
52
52
52
53
Sound power level (H)
dB(A)
65
69
69
69
69
70
Dimensions LxWxH
mm
845x320x700
900x315x860
938x392x1.369
Packing LxWxH
mm
965x395
x755
1.043x395
x915
1.095x495x1.505
Net/gross weight
Piping diameters
46/50
59/63
100/114
102/116
102/118
107/120
Liquid
inch
kg
6,35 (1/4”)
9,52 (3/8”)
9,52 (3/8”)
9,52 (3/8”)
9,52 (3/8”)
9,52 (3/8”)
Gas
inch
12,7 (1/2”)
15,9 (5/8”)
15,9 (5/8”)
15,9 (5/8”)
15,9 (5/8”)
15,9 (5/8”)
Drainage
mm
32
32
32
32
32
32
A
10
13
25
11
13
15
Max. input current
Maximum lenght of the line
m
30
50
65
65
65
65
Maximum height difference
m
20
25
30
30
30
30
Outdoor temperature
°C
-15 ... +50 cooling / heating -15 ... +24
Nominal conditions
Indoor unit
Outdoor unit
Piping lenght
Level difference
Cooling mode
27°C DB, 19°C WB
35°C DB
5m
0m
Heating mode
20°C DB, 19°C WB
7°C DB, 6°C WB
5m
0m
Seasonal efficiency according to EN 14825. Seasonal efficiency and energy labelling is not applicable to split systems with cooling capacity exceeding 12 kW.
The sound pressure value may vary depending on ambient conditions.
35
| Duct Inverter High efficiency Split
Duct Inverter High efficiency Split
SYSPLIT DUCT EVO HP
Features
SYSPLIT DUCT EVO air conditioners are designed using the
latest engineering solutions and allow their installation
with a minimum ceiling height.
Advanced DC inverter control for the compressor,
outdoor fan motor and indoor fan motor.
One indoor unit can serve several facilities through a
network of ducts to the high external static pressure.
Air conditioners are equipped with washable air filter.
Flexible air intake from the rear (factory standard), it
can be easily changed to bottom air intake using the
same flange plate.
The fresh air hole on the side of the unit makes easy
the connection to the external air intake.
Built-in drain pump can lift the condensate water up to
750 mm.
With the Auto-restart function the unit resumes with
the same settings before the electric power failure.
Environment friendly R410A refrigerant.
Wired remote controller SYSCONTROL WC 90 included;
Infrared remote
control
SYSCONTROL
RM 52
Art. no. 314137
(optional)
Wired
controller
SYSCONTROL
WC 90
(standard)
Infrared remote controller SYSCONTROL RM 52
available as accessory.
A
A
G
Dimensions
A
H
A
E E
C C
D D
12
18
24
36
48
60
760
845
900
938
938
938
530
E
C
D
A
18
24
36
48
60
Model
560
590
634
634
634
290
335
333
404
404
404
D
315
360
355
448
448
448
80
E
270
312
302
368
368
368
968
968
F
285
320
315
392
392
392
40
40
40
H
590
700
860
1.369
1.369
1.369
204
204
204
A
700
920
920
1.200
1.200
1.200
A
B
210
270
270
300
300
300
B
C
635
635
635
865
865
865
C
D
570
570
570
800
800
800
E
65
65
65
80
80
F
493
716
716
968
G
35
35
35
H
119
179
179
B
B
F
D
12 C
F F
D
C
H
A
A
BB
BB
Model
A
H H
F
E
size 36 to 60
B
F
E
Outdoor unit
size 12 to 24
H H
G
B
H
SYSPLIT DUCT
H
36
Duct Inverter High efficiency Split |
Technical features
SYSPLIT DUCT
12 EVO
HP Q
18 EVO
HP Q
24 EVO
HP Q
36 EVO
HP Q
36 EVO
HP Q
48 EVO
HP Q
60 EVO
HP Q
SYSPLIT OUTDOOR
12 EVO
HP Q
18 EVO
HP Q
24 EVO
HP Q
36 EVO
HP Q
36 EVO
HP R
48 EVO
HP R
60 EVO
HP R
Model Indoor unit
Model Outdoor unit
Art. no. Indoor unit
314026
314027
314022
314023
314023
314045
314047
Art. no. Outdoor unit
314056
314057
314058
314059
314060
314062
314063
R410A / 1,1
R410A / 1,8
R410A / 2,2
Refrigerant / Charged quantity
Power supply
kg
V/Ph/Hz
R410A / 4,3 R410A / 4,35 R410A / 3,8
380420/3/50
220-240/1/50
R410A / 4,6
380-420/3/50
kW
3,51
(1,11-4,59)
5,27
(1,29-7,37)
7,02
(1,48-8,77)
10,56
10,56
14,06
16,69
(2,92-13,15) (2,92-13,15) (4,33-15,64) (4,97-18,27)
Power consumption
W
1.080
(180-1.820)
1.460
(230-2.460)
2.060
(280-3.450)
3.290
(620-5.300)
Operating current
A
4.7
(0.8-7.9)
6.3
(1.0-10.7)
9.0
(1.2-15.0)
14.3
(2.8-23.6)
4.8
(1.1-9.1)
7.6
(2.2-10.9)
9.0
(2.5-12.8)
EER
3,25
3,61
3,41
3,21
3,80
3,21
3,21
SEER
5,3
6,4
6,7
6,0
6,1
-
-
A
A++
A++
A+
A++
-
-
kW
4,11
(0,99-4,68)
5,87
(1,08-7,37)
7,61
(1,32-9,50)
11,72
(3,8-14,03)
11,72
(3,8-14,03)
Power consumption
W
1.080
(180-1.620)
1.450
(230-2.380)
1.950
(280-3.420)
3.160
(780-5.000)
2.790
4.560
5.220
(780-5.000) (1.180-5.920) (1.390-6.990)
Operating current
A
4.7
(0.8-7.0)
6.3
(1.0-10.3)
8.5
(1.2-14.9)
13.7
(3.5-22.2)
4.8
(1.3-8.6)
7.9
(2.2-10.7)
9.0
(2.5-12.7)
COP
3,81
4,05
3,90
3,71
4,20
3,73
3,65
SCOP (Average)
3,8
3,8
3,8
3,8
3,8
-
-
A
A
A
A
A
-
-
800/
610/520
1.180/
770/650
1.400/
1.100/1.000
Cooling capacity
Energy label cooling
Heating capacity
Energy label heating
2.780
4.380
5.200
(620-5.300) (1.200-6.000) (1.380-7.050)
17,01
19,05
(4,97-18,56) (5,79-21,05)
Indoor Unit
Air flow rate (H/M/L)
External static pressure (Max)
m3/h
2.270/1.890/1.650
3.010/2.410/1.940
Pa
40
70
70
80
80
100
Sound pressure level (H)
dB(A)
40
42
46
45
44
46
100
46
Sound power level (H)
dB(A)
57
59
63
62
61
63
63
Dimensions LxWxH
mm
700x
635x210
920x635x270
1.200x865x300
Packing LxWxH
mm
915x
655x290
1.135x655x350
1.385x920x373
kg
18,1/22,8
28/31,5
28/31,5
44/52,5
44/52,5
44/55
45/53
Twin-rotary
Net/gross weight
Outdoor Unit
Type
Rotary
Rotary
Twin-rotary
Twin-rotary
Twin-rotary
Twin-rotary
Sound pressure level (H)
Compressor
dB(A)
44
48
52
52
52
52
53
Sound power level (H)
dB(A)
61
65
69
69
67
69
70
Dimensions LxWxH
mm
760x
285x590
845x
320x700
900x
315x860
938x392x1369
Packing LxWxH
mm
887x
355x645
965x
395x755
1.043x
395x915
1.095x495x1.505
Unit weight
35,4/37,9
46/50
59/63
100/114
102/116
102/118
107/120
Liquid
inch
6,35 (1/4”)
6,35 (1/4”)
9,52 (3/8”)
9,52 (3/8”)
9,52 (3/8”)
9,52 (3/8”)
9,52 (3/8”)
Gas
inch
9,52 (3/8”)
12,7 (1/2”)
15,9 (5/8”)
15,9 (5/8”)
15,9 (5/8”)
15,9 (5/8”)
15,9 (5/8”)
Drainage
mm
25
25
25
25
25
25
25
Max. input current
A
9,5
10
13
25
11
13
15
Maximum lenght of the line
m
20
30
50
65
65
65
65
Maximum height difference
m
10
20
25
30
30
30
30
Outdoor temperature
°C
Piping diameters
kg
-15 ... +50 cooling / heating -15 ... +24
Nominal conditions
Indoor unit
Outdoor unit
Piping lenght
Level difference
Cooling mode
27°C DB, 19°C WB
35°C DB
5m
0m
Heating mode
20°C DB, 19°C WB
7°C DB, 6°C WB
5m
0m
Seasonal efficiency according to EN 14825. Seasonal efficiency and energy labelling is not applicable to split systems with cooling capacity exceeding 12 kW.
The sound pressure value may vary depending on ambient conditions.
37
| Duct On/Off Split
Duct On/Off Split
SYSPLIT DUCT HT
Features
SYSPLIT DUCT HT air conditioners are suitable for large
commercial spaces providing highest cooling/heating
capacity and powerfull air flow.
One indoor unit can serve several facilities through a
network of ducts.
High external static pressure up to 200 Pa.
Air conditioners are equipped with washable air filter.
Environment friendly R410A refrigerant.
Cooling operation with outdoor temperature up to
+52°C.
With the Auto-restart function the unit resumes with
the same settings before the electric power failure
Environment friendly R410A refrigerant.
Wired remote controller SYSCONTROL WC 90 included;
Infrared remote controller SYSCONTROL RM 52
available as accessory.
Dimensions
5
330
656
469
76
1350
0
330
450
5
800
840
762
908
676
700
507
106 120
57
179
180
30
1260
45
638
330
654
SYSPLIT OUTDOOR 120 HTR
858
330
SYSPLIT OUTDOOR 120 HT R
45
SYSPLIT DUCT 120 HT Q
330
1895
Wired
controller
SYSCONTROL
WC 90
(standard)
SYSPLIT OUTDOOR 76/96 HT R
1260
180
26
1205
1828
Infrared remote
control
SYSCONTROL
RM 52
Art. no. 314137
(optional)
SYSPLIT OUTDOOR 76/96 HT R
SYSPLIT DUCT 76/96 HT Q
231
132
38
24
750
908
654
762
700
15
677
519
737
676
Duct On/Off Split |
Technical features
Model Indoor unit
SYSPLIT DUCT
76 HT Q
96 HT Q
120 HT Q
SYSPLIT OUTDOOR
76 HT R
96 HT R
120 HT R
Art. no. Indoor unit
314070
314071
314072
Art. no. Outdoor unit
314179
314180
314181
R410A / 5,4
R410A / 6,0
R410A / 7,2
Model Outdoor unit
Refrigerant / Charged quantity
kg
Power supply
V/Ph/Hz
Cooling capacity
380-415/3/50
kW
22,0
28,0
35,0
Power consumption
W
7.500
9.600
12.000
Rated current
A
19,3
23,7
28,6
2,93
2,92
2,92
kW
25,0
31,0
38,0
Power consumption
W
8.300
10.300
12.600
Rated current
A
21,3
26,5
31,5
3,01
3,01
3,02
4.250/3.760/3.220
5.100/4.410/3.760
EER
Heating capacity
COP
Indoor Unit
Power supply
V/Ph/Hz
m3/h
Air flow rate (H/M/L)
External static pressure (Hi)
220-240/1/50
Pa
Sound pressure level (H)
6.375/5.920/5.430
200
dB(A)
150
53
54
56
Dimensions (LxWxH)
mm
1.350x760x450
1.828x858x638
Packing LxWxH
mm
1.549x917x476
2.095x929x689
105/120
188/220
Net/gross weight
kg
Outdoor Unit
Power supply
V/Ph/Hz
380-415/3/50
Compressor
Type
Scroll
Scroll
Scroll
Air flow rate
m3/h
7.200
10.400
12.000
dB(A)
65
67
69
Sound pressure level (Hi)
Dimensions (LxWxH)
mm
Packing LxWxH
mm
Net/gross weight
Piping diameters
kg
Liquid
inch
Gas
inch
Drainage
mm
Locked rotor amp
A
Maximum lenght of the line
m
1.260x908x700
1.320x1.060x730
174/193
187/204
201/217
9,52 (3/8”)
22,2 (7/8”)
12,7 (1/2”)
25,4 (1”)
28,6 (1 1/8”)
41
110
110
147
50
Maximum height difference
m
30
Outdoor temperature
°C
+21 ... +52 cooling / heating -10 ... +24
Fan performance
SYSPLIT DUCT 120 HT Q
260
240
Med
Hi
Lo
220
200
180
160
140
120
100
80
60
40
20
0
3500 3750 4000 4250 4500 4750 5000 5250 5500 5750 6000
Air Flow(m3/h)
200
Lo
180
Static Pressure (Pa)
260
240
Hi
Lo
Med
220
200
180
160
140
120
100
80
60
40
20
0
2750 3000 3250 3500 3750 4000 4250 4500 4750 5000 5250
SYSPLIT DUCT 96 HT Q
Static Pressure (Pa)
Static Pressure(Pa)
SYSPLIT DUCT 76 HT Q
Med
Hi
160
140
120
100
80
60
40
20
0
4250
4750
5250
Air Flow (m3/h)
5750
6250
Air Flow (m3/h)
6750
7250
Nominal conditions
Indoor unit
Outdoor unit
Piping lenght
Level difference
Cooling mode
27°C DB, 19°C WB
35°C DB
5m
0m
Heating mode
20°C DB, 19°C WB
7°C DB, 6°C WB
5m
0m
The sound pressure value may vary depending on ambient conditions.
7750
39
40
| VRF systems
SYSVRF
VRF systems |
SYSVRF multi-zone solutions:
light commercial and commercial VRF systems
The SYSVRF modular systems are most valuable for room
space from 100 to 1000 sq.m. with large independence
of climatic zones - hotels, restaurants, retail, office
buildings, etc. Up to 4 modular outdoor units can be
combined in one single refrigerant system thus reaching
up to 200kW of cooling capacity and connecting up to 64
indoor units. In the same system they are able to fulfill
the increasing demands of air comfort still having low
operating costs.
All SYSVRF systems are equipped with DC Inverter
compressors and DC Inverter fans which gives enhanced
system performance and very low operating noise.
The new generation of 3-pipe systems are equipped with
all DC Inverter compressor which delivers outstanding
comfort pleasure and reduces tremendously the
electricity consumption.
SYSVRF of Systemair are available with different configurations: the typical heat pump Mini and Modular 2-pipe outdoor
units Air-cooled or Water-cooled and the superior Modular heat recovery 3-pipe units.
SYSVRF Mini and SYSVRF Modular systems
SYSVRF AIR EVO HP Mini
44
SYSVRF DUCT
72
SYSVRF AIR EVO HP
46
SYSVRF DUCT HP
74
SYSVRF AIR EVO HR
50
SYSVRF FLOOR EB
76
SYSVRF WATER EVO HP
56
SYSVRF FLOOR CB
78
SYSVRF WALL
60
SYSVRF HRV
80
SYSVRF CASSETTE MINI
62
SYSCONTROL AHU
82
SYSVRF CASSETTE
64
SYSVRF selection software
83
SYSVRF CASSETTE 1 WAY
66
SYSCONTROL systems
84
SYSVRF CASSETTE 2 WAY
68
SYSVRF JOINT accessories
86
SYSVRF CEILING
70
41
42
| VRF systems
VRF Systemair- SYSVRF
Multi-zone air conditioning system
VRF systems are most beneficial for space up to 15002000 sq.m. with large independence of climatic zones –
hotels, restaurants, retail space, office buildings, etc.
In the same system they are able to fulfill the increasing
demands of the parameters of air in each room and still
have low operating costs.
The most comfortable temperature
An important advantage of the multi-zone air-conditioning
is a smooth and rapid achievement of a comfortable
temperature, as well as maintaining the specified
parameters accurate to ± 0,5 °C. Such high performance
was achieved thanks to an accurate control of the
refrigerant flow and the mechanism of redistribution of
refrigerant between the several units, implemented with
the help of electronic expansion valves.
High energy efficiency
The efficiency of multi-zone systems is very high, because
each time the electric power is consumed as much as
necessary to carry out user requirements.
If the indoor units work only in a few areas of the building,
then the power consumption is reduced proportionally by
changing the refrigerant flow.
Low noise
Low noise of both outdoor and indoor units makes the job
a multizone system virtually inconspicuous.
A balanced lineup
The lineup of multizone VRF series are continuously
optimized. In response to market demands Systemair
offers several types and sizes of indoor units: wallmounted, cassette, floor-ceiling and duct.
Outdoor units Mini, despite the compact dimensions ,
solve different tasks of air conditioning on small objects.
Six modular outdoor units can be combined in one
refrigerant system thus reaching a total cooling capacity
of up to 200 kW.
Separately, to highlight the 3 Pipe heat recovery system
for indipendent and simultaneous cooling and heating
operation.
Continuous development in the field of management
In modern air-conditioning systems the demand for
automation and control systems integrated with other
infrastructure building systems is continuously increasing.
These are exactly the principles on the basic of the
development of the control systems of Systemair.
In addition to the traditional control systems of air
conditioning, the user deals with different possibilities of
control that can solve the various needs of the building
management such as the possibility of control via
personal computer and Internet network connection.
Simplicity of design
Systemair provides full integration and coordination of
all elements of a multizone system, greatly simplifies
the task of the designer. The selection process can be
performed in maximum short period of time by using a
simple and complete selection and designing software.
VRF systems |
SYSVRF lineup
In 2014 Systemair has launched a new generation of VRF multi-zone systems - the SYSVRF series. The basis principle of
work lies on the advantages of the DC Inverter technology and scroll compressors and the achieved results far exceed the
high standards set by the industry.
Through the use of modern technologies and implementation of their own development has significantly improved energy
efficiency and decreased the noise level, with compact dimensions, increased ease of installation and maintenance,
greatly expanded the range of application from light commercial to large commercial spaces.
SYSVRF outdoor units
SYSVRF mini
2 Pipe Heat Pump
12,0-16,0 kW
SYSVRF AIR EVO HR
Modular 3 Pipe Heat Recovery
25,0-180,0 kW
SYSVRF AIR EVO HP
Modular 2 Pipe Heat Pump
25,0 - 200,0 kW
SYSVRF WATER EVO HP
Modular 2 Pipe Heat Pump
25,0 - 100,0 kW
SYSVRF WALL
SYSVRF CEILING
SYSVRF CASSETTE MINI
SYSVRF Indoor units
1,5-5,6 kW
SYSVRF CASSETTE
2,8-14,0 kW
SYSVRF DUCT
3,6-14,0 kW
SYSVRF CASSETTE 1 WAY
1,8-3,6 kW
SYSVRF DUCT HP
2,2-5,6 kW
SYSVRF CASSETTE 2 WAY
2,2-5,6 kW
SYSVRF HRV
2,2-14,0 kW
7,1-28,0 kW
500-2.000 m3/h
SYSVRF FLOOR EB
SYSVRF FLOOR CB
SYSCONTROL AHU
2,2-8,0 kW
2,2-8,0 kW
9,0-56 kW
Compatible outdoor and indoor series
Outdoor units of the SYSVRF Mini, Heat Pump and Heat Recovery series are compatible with all types of SYSVRF indoor
units. There are 10 different types of indoor units available with capacity from 1,5 kW to 28,0 kW, making the total number
of indoor units equal to 63 different types and capacities.
The ventilation function can be provided through the SYSVRF HRV units or through the combination of a Systemair air
handling unit with the control module SYSCONTROL AHU.
43
| Mini VRF
Mini VRF Heat Pump Outdoor Units
SYSVRF AIR EVO HP
Features
Full DC Inverter Mini VRF with DC Inverter compressor
and DC fan motor.
Compact size and long piping system.
High efficiency at partial load.
Inverter Rotary compressor providing wide capacity
output from 10% to 100% evenly.
Centralized control, BMS connection and web access
potential.
Hydrophilic Blue Fin coil enhances durability
and protection against corrosion.
Piping connection in four different directions makes
simple the installation of outdoor unit.
Maximum 7 indoor units connection.
Indoor unit combination total capacity index from 45%
to 130%.
H
Dimensions
A
F
E
D
B
C
44
Model
120
140
160
A
900
900
900
B
600
600
600
C
348
348
348
D
320
320
320
E
400
400
400
F
360
360
360
H
1.327
1.327
1.327
Mini VRF |
Technical features
Model Indoor unit
SYSVRF
120 AIR EVO HP Q
140 AIR EVO HP R
160 AIR EVO HP R
314089
314092
314094
Art. no.
Power Supply
V/Ph/Hz
220-240/1/50
380-415/3/50
Cooling capacity
kW
12,3
14,0
15,5
Power Input
kW
3,25
3,95
4,52
3,78
3,54
3,43
Heating capacity
kW
13,2
15,4
17,0
Power Input
kW
3,47
4,16
4,77
3,80
3,70
EER
COP
Max. current
Compressor
Inverter Rotary
A
Quantity
12
pcs
1
Power Input
W
3.010
3.010
4.240
Refrigerant oil
ml
870+630
870+630
1.400+250
Outdoor fan type / motor
2 Axial / 2 DC fan motors
m3/h
Air flow
Sound pressure level
Refrigerant
6.000
dB(A)
57
Type
R410A
Refrigerant charge
kg
Dimension LxWxH
mm
Packing LxWxH
mm
Net/gross weight
Piping dimension
3,56
36
3,3
mm (in)
Gas pipe
mm (in)
Max qty. indoor units connection
pcs
Operating ambient temp. range
°C
3,9
1.030x435x1.456
kg
Liquid pipe
3,9
900x320x1.327
95/106
95/106
102/113
9,5 (3/8”)
15,9 (5/8”)
6
6
7
Cooling -15 ... +48 / Heating -15 ... +27
Nominal conditions
Indoor unit
Outdoor unit
Piping lenght
Level difference
Cooling mode
27°C DB, 19°C WB
35°C DB
5m
0m
Heating mode
20°C DB, 19°C WB
7°C DB, 6°C WB
5m
0m
The sound pressure value may vary depending on ambient conditions.
Piping Lenght
Maximum piping equivalent lenght.
Maximum piping (the farthest IDU from the first indoor unit
branch) equivalent lenght.
100 m
Maximum outdoor unit-indoor unit drop height.
30 m
Maximum indoor unit to indoor unit drop height.
20 m
Outdoor units SYSVRF AIR EVO HP
Permitted value
Total piping lenght (actual)
Piping lenght
Maximum piping
100 m
Actual lenght
60 m
Equivavent lenght
70 m
Piping (the farthest IDU from the first indoor unit branch)
equivalent lenght
Drop height
8m
Outdoor unit-indoor
unit drop height
Indoor unit to indoor unit drop height
20 m
Outdoor unit up
30 m
Outdoor unit down
20 m
8m
45
| VRF Heat Pump
Modular VRF Heat Pump Outdoor Units
SYSVRF AIR EVO HP
SYSVRF 252-280
AIR EVO HP R
Features
Wide application area due to incredible piping lenght
and wide operating temperature range.
Free modular combination of 6 basic units, up to a total
capacity of maximum 200 kW.
Top class energy efficiency.
DC Inverter Scroll compressor provinding wide capacity
output from 10% to 100% evenly.
All DC fan motor.
High performance of the new designed heat
exchanger.
External static pressure up to 60 Pa (factory option, 20
Pa standard).
Maximum 64 indoor unit connection.
Indoor unit combination total capacity index from 50%
to 130%.
Centralized control, BMS connection and web access
potential.
SYSVRF 335-400-450
AIR EVO HP R
SYSVRF 500 AIR EVO HP R
Dimensions
SYSVRF 252/280 AIR EVO HP R
SYSVRF 335/400/450/500 AIR EVO HP R
1615
1615
1250
765
960
765
46
VRF Heat Pump |
Technical features
Model Indoor unit
SYSVRF
Art. no.
Power Supply
252 AIR
EVO HP R
280 AIR
EVO HP R
335 AIR
EVO HP R
400 AIR
EVO HP R
450 AIR
EVO HP R
500 AIR
EVO HP R
314259
314260
314251
314252
314253
314254
V/Ph/Hz
380-415/3/50
Cooling capacity
kW
25,2
28,0
33,5
40,0
45,0
50,0
Power Input
kW
5,88
7,20
9,05
12,31
14,02
15,20
EER
4,29
3,89
3,7
3,25
3,21
3,29
Heating capacity
kW
27,0
31,5
37,5
45,0
50,0
56,0
Power Input
kW
6,15
7,61
8,99
11,19
12,79
14,25
4,39
4,14
4,17
4,02
3,91
3,93
20,8
22,1
23,7
31,8
32,8
35,4
COP
Max. current
Compressor
Inverter Scroll
Compressor
Fixed Scroll
A
Quantity
pcs
1
Capacity
W
31.590
31.590
11.800
31.590
31.590
31.590
Refrigerant oil
ml
500
500
500
500
500
500
Quantity
pcs
-
-
1
1
1
1
Capacity
W
-
-
17.100
13.390
13.390
20.900
Refrigerant oil
ml
-
-
500
500
500
500
Outdoor fan type / motor
1 Axial / 1 DC fan motor
Air flow
Sound pressure level
Refrigerant
m3/h
11.500
15.100
dB(A)
57
59
Type
15.600
15.600
15.600
60
61
13
16
R410A
Refrigerant charge
kg
9
Dimension (LxWxH)
mm
960x765x1.615
Packing (LxWxH)
mm
1.025x830x1.790
Net/gross weight
kg
Piping dimension
2 Axial / 2 DC fan motors
11
1.250x765x1.615
1.305x825x1.790
198/213
266/288
280/300
300/320
Liquid pipe
mm (in)
12,7 (1/2”)
15,9 (5/8”)
19,1 (3/4”)
Gas pipe
mm (in)
25,4 (1”)
31,8 (1 1/4”)
31,8 (1 1/4”)
Oil balance pipe
mm (in)
Operating ambient temp. range
6,35 (1/4”)
°C
Cooling -5 ... +48 / Heating -20 ... +24
Nominal conditions
Indoor unit
Outdoor unit
Piping lenght
Level difference
Cooling mode
27°C DB, 19°C WB
35°C DB
5m
0m
Heating mode
20°C DB, 19°C WB
7°C DB, 6°C WB
5m
0m
The sound pressure value may vary depending on ambient conditions.
Piping Lenght
Maximum piping equivalent lenght.
Maximum piping (the farthest IDU from the first indoor unit
branch) equivalent lenght.
Maximum outdoor unit-indoor unit drop height.
Maximum indoor unit to indoor unit drop height.
Outdoor units SYSVRF 252 to 2000 AIR EVO HP R
Permitted value
Total piping lenght (actual)
Piping lenght
Maximum piping
1.000 m
Actual lenght
175 m
Equivavent lenght
200 m
Piping (the farthest IDU from the first indoor unit branch)
equivalent lenght
Drop height
Outdoor unit-indoor
unit drop height
Outdoor unit down
Outdoor unit up
Indoor unit to indoor unit drop height
* When the farthest pipe length is more than 40m, it needs to meet specific conditions according to the installation part of the technical manual.
** Level difference: less or equal to 50m is standard; more than 50m is available to be customized.
40 m/90 m*
110 m
50 m/70 m**
30 m
47
48
| VRF Heat Pump combination
Outdoor unit combination SYSVRF AIR EVO HP
Design
Cooling/
Heating
capacity kW
Model
Recommended
combination
Outdoor
branch
Max.
indoor
unit qty
25,2/27
SYSVRF 252 AIR EVO HP R
SYSVRF 252 AIR EVO HP R
-
13
28/31,5
SYSVRF 280 AIR EVO HP R
SYSVRF 280 AIR EVO HP R
-
16
33,5/37,5
SYSVRF 335 AIR EVO HP R
SYSVRF 335 AIR EVO HP R
-
20
40/45
SYSVRF 400 AIR EVO HP R
SYSVRF 400 AIR EVO HP R
-
23
45/50
SYSVRF 450 AIR EVO HP R
SYSVRF 450 AIR EVO HP R
-
26
50/56
SYSVRF 500 AIR EVO HP R
SYSVRF 500 AIR EVO HP R
-
29
56/63
SYSVRF 560 AIR EVO HP R
SYSVRF 280 AIR EVO HP R x2
SYSVRF JOINT
OUT 02 HP
33
61,5/69
SYSVRF 615 AIR EVO HP R
SYSVRF 280 AIR EVO HP R
+ SYSVRF 335 AIR EVO HP R
SYSVRF JOINT
OUT 02 HP
36
68/76,5
SYSVRF 680 AIR EVO HP R
SYSVRF 280 AIR EVO HP R
+ SYSVRF 400 AIR EVO HP R
SYSVRF JOINT
OUT 02 HP
39
73/81,5
SYSVRF 730 AIR EVO HP R
SYSVRF 280 AIR EVO HP R
+ SYSVRF 450 AIR EVO HP R
SYSVRF JOINT
OUT 02 HP
43
78/87,5
SYSVRF 780 AIR EVO HP R
SYSVRF 280 AIR EVO HP R
+ SYSVRF 500 AIR EVO HP R
SYSVRF JOINT
OUT 02 HP
46
85/95
SYSVRF 850 AIR EVO HP R
SYSVRF 400 AIR EVO HP R
+ SYSVRF 450 AIR EVO HP R
SYSVRF JOINT
OUT 02 HP
50
90/101
SYSVRF 900 AIR EVO HP R
SYSVRF 400 AIR EVO HP R
+ SYSVRF 500 AIR EVO HP R
SYSVRF JOINT
OUT 02 HP
53
95/106
SYSVRF 950 AIR EVO HP R
SYSVRF 450 AIR EVO HP R
+ SYSVRF 500 AIR EVO HP R
SYSVRF JOINT
OUT 02 HP
56
100/112
SYSVRF 1000 AIR EVO HP R
SYSVRF 500 AIR EVO HP R x2
SYSVRF JOINT
OUT 02 HP
59
VRF Heat Pump combination |
Design
Cooling/
Heating
capacity kW
Model
Recommended
combination
Outdoor
branch
Max.
indoor
unit qty
106/119
SYSVRF 1060 AIR EVO HP R
SYSVRF 280 AIR EVO HP R x2
+ SYSVRF 500 AIR EVO HP R
SYSVRF JOINT
OUT 03 HP
63
113/126,5
SYSVRF 1130 AIR EVO HP R
SYSVRF 280 AIR EVO HP R
+ SYSVRF 400 AIR EVO HP R
+ SYSVRF 450 AIR EVO HP R
SYSVRF JOINT
OUT 03 HP
64
120/135
SYSVRF 1200 AIR EVO HP R
SYSVRF 400 AIR EVO HP R x3
SYSVRF JOINT
OUT 03 HP
64
123/137,5
SYSVRF 1230 AIR EVO HP R
SYSVRF 280 AIR EVO HP R
+ SYSVRF 450 AIR EVO HP R
+ SYSVRF 500 AIR EVO HP R
SYSVRF JOINT
OUT 03 HP
64
128/143,5
SYSVRF 1280 AIR EVO HP R
SYSVRF 280 AIR EVO HP R +
SYSVRF 500 AIR EVO HP R x2
SYSVRF JOINT
OUT 03 HP
64
135/151
SYSVRF 1350 AIR EVO HP R
SYSVRF 400 AIR EVO HP R
+ SYSVRF 450 AIR EVO HP R
+ SYSVRF 500 AIR EVO HP R
SYSVRF JOINT
OUT 03 HP
64
140/157
SYSVRF 1400 AIR EVO HP R
SYSVRF 400 AIR EVO HP R +
SYSVRF 500 AIR EVO HP R x2
SYSVRF JOINT
OUT 03 HP
64
145/162
SYSVRF 1450 AIR EVO HP R
SYSVRF 450 AIR EVO HP R +
SYSVRF 500 AIR EVO HP R x2
SYSVRF JOINT
OUT 03 HP
64
150/168
SYSVRF 1500 AIR EVO HP R
SYSVRF 500 AIR EVO HP R x3
SYSVRF JOINT
OUT 03 HP
64
156/175
SYSVRF 1560 AIR EVO HP R
SYSVRF 280 AIR EVO HP R x2
+ SYSVRF 500 AIR EVO HP R x2
SYSVRF JOINT
OUT 04 HP
64
163/182,5
SYSVRF 1630 AIR EVO HP R
SYSVRF 280 AIR EVO HP R
+ SYSVRF 400 AIR EVO HP R
+ SYSVRF 450 AIR EVO HP R
+ SYSVRF 500 AIR EVO HP R
SYSVRF JOINT
OUT 04 HP
64
168/188,5
SYSVRF 1680 AIR EVO HP R
SYSVRF 280 AIR EVO HP R
+ SYSVRF 400 AIR EVO HP R
+ SYSVRF 500 AIR EVO HP R x 2
SYSVRF JOINT
OUT 04 HP
64
173/193,5
SYSVRF 1730 AIR EVO HP R
SYSVRF 280 AIR EVO HP R
+ SYSVRF 450 AIR EVO HP R
+ SYSVRF 500 AIR EVO HP R x 2
SYSVRF JOINT
OUT 04 HP
64
178/199,5
SYSVRF 1780 AIR EVO HP R
SYSVRF 280 AIR EVO HP R +
SYSVRF 500 AIR EVO HP R x 3
SYSVRF JOINT
OUT 04 HP
64
185/207
SYSVRF 1850 AIR EVO HP R
SYSVRF 400 AIR EVO HP R +
SYSVRF 450 AIR EVO HP R +
SYSVRF 500 AIR EVO HP R x 2
SYSVRF JOINT
OUT 04 HP
64
190/213
SYSVRF 1900 AIR EVO HP R
SYSVRF 400 AIR EVO HP R +
SYSVRF 500 AIR EVO HP R x 3
SYSVRF JOINT
OUT 04 HP
64
195/218
SYSVRF 1950 AIR EVO HP R
SYSVRF 450 AIR EVO HP R +
SYSVRF 500 AIR EVO HP R x 3
SYSVRF JOINT
OUT 04 HP
64
200/224
SYSVRF 2000 AIR EVO HP R
SYSVRF 500 AIR EVO HP R x 4
SYSVRF JOINT
OUT 04 HP
64
49
| VRF Heat Recovery
Modular VRF Heat Recovery Outdoor Units
SYSVRF AIR EVO HR
Features
Simultaneous operation in cooling and heating mode
provides more comfort and reduces power consumption.
Wide application area due to incredible piping lenght
and wide operating temperature range.
Free modular combination of 5 basic units, up to a total
capacity of maximum 180 kW.
Top class energy efficiency.
All DC Inverter Scroll compressors providing wide
capacity output from 10% to 100% evenly.
DC fan motor.
High performance of the new designed heat
exchanger with double refrigerant circuit.
External static pressure up to 40 Pa (20 Pa standard).
Maximum 64 indoor unit connection.
Indoor unit combination total capacity index from 50%
to 130%.
Centralized control, BMS connection and web access
potential.
Continous heating output during defrost operation
thanks to the innovative double heat exchanger.
1250
Dimensions
1615
SYSVRF 252/280/335/400/450 AIR EVO HR R
765
1615
1250
765
50
VRF Heat Recovery |
Technical features
Model Indoor unit
SYSVRF
Art. no.
Power Supply
252 AIR EVO
HR R
280 AIR EVO
HR R
335 AIR EVO
HR R
400 AIR EVO
HR R
450 AIR EVO
HR R
314084
314085
314086
314087
314088
V/Ph/Hz
380-415/3/50, 380-415/3/60
Cooling capacity
kW
25,2
28,0
33,5
40,0
45,0
Power Input
kW
5,73
6,67
8,07
11,30
13,24
3,40
EER
4,40
4,20
4,15
3,54
Heating capacity
kW
27,0
31,5
37,5
45,0
50,0
Power Input
kW
6,00
7,33
8,72
11,19
12,79
COP
Max. current
Compressor
Inverter Scroll
A
4,30
4,30
4,02
3,91
20,8
22,1
22,8
31,8
32,8
2
2
Quantity
pcs
1
1
1
Capacity
W
31.590
31.590
31.590
Refrigerant oil
ml
m3/h
Air flow
Sound pressure level
Refrigerant
4,50
31.590+11.800
500
500
500
12.000
12.000
13.000
15.000
15.000
58
60
60
dB(A)
57
Type
500+500
R410A
Refrigerant charge
kg
10
10
10
14
Dimension (LxWxH)
mm
1.250x765x1.615
1.250x765x1.615
Packing (LxWxH)
mm
1.305x825x1.790
1.350x825x1.790
Net/gross weight
kg
Piping dimension
255/273
303/322
Liquid pipe
mm (in)
9,5 (3/8”)
12,7 (1/2”)
12,7 (1/2”)
15,9 (5/8”)
15,9 (5/8”)
Low pressure gas pipe
mm (in)
22,2 (7/8”)
22,2 (7/8”)
25,4 (1”)
28,6 (1 1/8”)
28,6 (1 1/8”)
High pressure gas pipe
mm (in)
19,1 (3/4”)
19,1 (3/4”)
19,1 (3/4”)
19,1 (3/4”)
19,1 (3/4”)
Oil balance pipe
mm (in)
19,1 (3/4”)
19,1 (3/4”)
19,1 (3/4”)
22,2 (7/8”)
22,2 (7/8”)
Gas balance pipe
mm (in)
6,0 (1/4”)
6,0 (1/4”)
6,0 (1/4”)
6,0 (1/4”)
6,0 (1/4”)
Operating ambient temp. range
°C
Cooling -5...+48 / Heating -20...+24 / Simultaneous Cooling and Heating -5...+24
Nominal conditions
Indoor unit
Outdoor unit
Piping lenght
Level difference
Cooling mode
27°C DB, 19°C WB
35°C DB
7,5 m
0m
Heating mode
20°C DB, 15°C WB
7°C
7,5 m
0m
The sound pressure value may vary depending on ambient conditions.
Piping Lenght
Maximum piping equivalent lenght.
Maximum piping (the farthest IDU from the first indoor unit
branch) equivalent lenght.
Maximum outdoor unit-indoor unit drop height.
Maximum indoor unit to indoor unit drop height.
Outdoor units SYSVRF 252 to 1800 AIR EVO HR R
Permitted value
Total piping lenght (actual)
Piping lenght
Maximum piping
1.000 m
Actual lenght
175 m
Aquivavent lenght
200 m
Piping (the farthest IDU from the first indoor unit branch)
equivalent lenght
Drop height
Outdoor unit-indoor
unit drop height
Outdoor unit up
Outdoor unit down
Indoor unit to indoor unit drop height
* When the farthest pipe length is more than 40m, it needs to meet specific conditions according to the installation part of the technical manual.
** Level difference: less or equal to 50m is standard; more than 50m is available to be customized.
40 m/90 m*
110 m
50 m/70 m**
30 m
51
52
| VRF Heat Recovery switch module
Mode Switch module
for VRF Heat Recovery systems
SYSVRF BOX HR
Features
SYSVRF BOX 02 HR
Simultaneous heating and cooling in a single refrigerant
system thanks to the combination of SYSVRF HR
outdoor units and the SYSVRF BOX modules.
SYSVRF BOX HR is available in 3 different modules with
2, 4 or 6 outlets and combination up to 24 indoor units
from a single module.
SYSVRF BOX 02-1 HR and 04-1 HR can connect only
one indoor unit and they are specifically designed for
the combination with SYSCONTROL AHU and Systemair
air handling units.
Compact and light design, it can be installed in narrow
space.
Heating
Heating
Heating
SYSVRF BOX 06 HR
SYSVRF BOX 04 HR
Independent sub-cooling circuit for each SYSVRF BOX
HR module.
Off
Cooling
Cooling
Dimensions SYSVRF BOX
SYSVRF BOX
02 HR
SYSVRF BOX
04 HR
SYSVRF BOX
06 HR
A
630
960
960
B
600
600
600
C
225
225
225
D
490
820
820
E
300
300
300
VRF Heat Recovery switch module |
Technical features
SYSVRF BOX
02 HR
Model
Art. no.
314161
Power Supply
V/Ph/Hz
SYSVRF BOX
04 HR
SYSVRF BOX
06 HR
314162
314186
220-240/1/50
Max indoor unit groups
2
4
6
Max number of each group indoor units
4
4
4
4x6=24
4x2=8
4x4=16
Max capacity of each group indoor units
Max number of all downstream indoor units
kW
16
16
16
Total capacity of all downstream indoor units
kW
<28
<45
<45
15,9 (5/8”)
Connect to outdoor unit
Piping connections
Connect to indoor unit
Liquid pipe
mm (in)
12,7 (1/2”)
15,9 (5/8”)
High pressureg gas pipe
mm (in)
19,1 (3/4”)
22,2 (7/8”)
22,2 (7/8”)
Low pressure gas pipe
mm (in)
25,4 (1”)
31,8 (1 1/4”)
31,8 (1 1/4”)
Liquid pipe
mm (in)
9,5 (3/8”)
9,5 (3/8”)
9,5 (3/8”)
Gas pipe
mm (in)
15,9 (5/8”)
15,9 (5/8”)
15,9 (5/8”)
Dimension (LxWxH)
mm
630x225x600
960x225x600
960x225x600
Packing (LxWxH)
mm
725x325x685
1.055x325x685
1.055x325x685
Net/gross weight
kg
19,5/27
31/40
35/44,5
SYSVRF BOX
02-1 HR
Model
Art. no.
313550
Power Supply
V/Ph/Hz
Max number of indoor unit
Max capacity of indoor unit
Piping
connections
SYSVRF BOX
04-1 HR
Connect to outdoor unit
Connect to indoor unit
kW
313551
220-240/1/50
1
1
20-28
40-56
15,9 (5/8”)
Liquid pipe
mm (in)
12,7 (1/2”)
High pressure gas pipe
mm (in)
19,1 (3/4”)
22,2 (5/8”)
Low pressure gas pipe
mm (in)
25,4 (1”)
31,8 (1 1/4”)
Liquid pipe
mm (in)
9,5 (3/8”)
9,5 (3/8”)
Gas pipe
mm (in)
15,9 (5/8”)
15,9 (5/8”)
Dimension (LxWxH)
mm
630x225x600
960x225x600
Packing (LxWxH)
mm
725x325x685
1.055x325x685
Net/gross weight
kg
19,5/27
31/40
Piping connections SYSVRF BOX
Outdoor unit
Indoor unit
SYSVRF BOX 02 HR
SYSVRF BOX 04 HR
SYSVRF BOX 06 HR
Liquid pipe
12,7 (1/2”)
15,9 (5/8”)
15,9 (5/8”)
High pressure pipe
19,1 (3/4”)
22,2 (7/8”)
22,2 (7/8”)
Low pressure pipe
25,4 (1”)
31,8 (1 1/4”)
31,8 (1 1/4”)
Liquid pipe
9,5 (3/8”)
9,5 (3/8”)
9,5 (3/8”)
Gas pipe
15,9 (5/8”)
15,9 (5/8”)
15,9 (5/8”)
53
54
| VRF Heat Recovery combination
Outdoor unit combination SYSVRF AIR EVO HR
Design
Cooling/
Heating
capacity kW
Model
Recommended
combination
Outdoor
branch
Max.
indoor
unit qty
25,2/27
SYSVRF 252 AIR EVO HR R
SYSVRF 252 AIR EVO HR R
-
13
28/31,5
SYSVRF 280 AIR EVO HR R
SYSVRF 280 AIR EVO HR R
-
16
33,5/37,5
SYSVRF 335 AIR EVO HR R
SYSVRF 335 AIR EVO HR R
-
20
40/45
SYSVRF 400 AIR EVO HR R
SYSVRF 400 AIR EVO HR R
-
23
45/50
SYSVRF 450 AIR EVO HR R
SYSVRF 450 AIR EVO HR R
-
26
53,2/58,5
SYSVRF 532 AIR EVO HR R
SYSVRF 252 AIR EVO HR R
+ SYSVRF 280 AIR EVO HR R
SYSVRF JOINT
OUT 02 HR
29
56/63
SYSVRF 560 AIR EVO HR R
SYSVRF 280 AIR EVO HR R x2
SYSVRF JOINT
OUT 02 HR
33
61,5/69
SYSVRF 615 AIR EVO HR R
SYSVRF 280 AIR EVO HR R
+ SYSVRF 335 AIR EVO HR R
SYSVRF JOINT
OUT 02 HR
36
68/76,5
SYSVRF 680 AIR EVO HR R
SYSVRF 280 AIR EVO HR R
+ SYSVRF 400 AIR EVO HR R
SYSVRF JOINT
OUT 02 HR
39
73/81,5
SYSVRF 730 AIR EVO HR R
SYSVRF 280 AIR EVO HR R
+ SYSVRF 450 AIR EVO HR R
SYSVRF JOINT
OUT 02 HR
43
80/90
SYSVRF 800 AIR EVO HR R
SYSVRF 400 AIR EVO HR R x2
SYSVRF JOINT
OUT 02 HR
46
85/95
SYSVRF 850 AIR EVO HR R
SYSVRF 400 AIR EVO HR R
+ SYSVRF 450 AIR EVO HR R
SYSVRF JOINT
OUT 02 HR
50
90/100
SYSVRF 900 AIR EVO HR R
SYSVRF 450 AIR EVO HR R x2
SYSVRF JOINT
OUT 02 HR
53
VRF Heat Recovery combination |
Design
Cooling/
Heating
capacity kW
Model
Recommended
combination
Outdoor
branch
Max.
indoor
unit qty
96/108
SYSVRF 960 AIR EVO HR R
SYSVRF 280 AIR EVO HR R x2
+ SYSVRF 400 AIR EVO HR R
SYSVRF JOINT
OUT 03 HR
56
101/113
SYSVRF 1010 AIR EVO HR R
SYSVRF 280 AIR EVO HR R x2
+ SYSVRF 450 AIR EVO HR R
SYSVRF JOINT
OUT 03 HR
59
106,5/119
SYSVRF 1065 AIR EVO HR R
SYSVRF 280 AIR EVO HR R
+ SYSVRF 335 AIR EVO HR R
+ SYSVRF 450 AIR EVO HR R
SYSVRF JOINT
OUT 03 HR
63
113/126,5
SYSVRF 1130 AIR EVO HR R
SYSVRF 280 AIR EVO HR R
+ SYSVRF 400 AIR EVO HR R
+ SYSVRF 450 AIR EVO HR R
SYSVRF JOINT
OUT 03 HR
64
120/135
SYSVRF 1200 AIR EVO HR R
SYSVRF 400 AIR EVO HR R x3
SYSVRF JOINT
OUT 03 HR
64
125/140
SYSVRF 1250 AIR EVO HR R
SYSVRF 400 AIR EVO HR R x2
+ SYSVRF 450 AIR EVO HR R
SYSVRF JOINT
OUT 03 HR
64
130/145
SYSVRF 1300 AIR EVO HR R
SYSVRF 400 AIR EVO HR R +
SYSVRF 450 AIR EVO HR R x2
SYSVRF JOINT
OUT 03 HR
64
135/150
SYSVRF 1350 AIR EVO HR R
SYSVRF 450 AIR EVO HR R x3
SYSVRF JOINT
OUT 03 HR
64
143,2/158,5
SYSVRF 1432 AIR EVO HR R
SYSVRF 252 AIR EVO HR R+
SYSVRF 280 AIR EVO HR R +
SYSVRF 450 AIR EVO HR R x2
SYSVRF JOINT
OUT 04 HR
64
146/163
SYSVRF 1460 AIR EVO HR R
SYSVRF 280 AIR EVO HR R x2
+ SYSVRF 450 AIR EVO HR R x2
SYSVRF JOINT
OUT 04 HR
64
151,5/169
SYSVRF 1515 AIR EVO HR R
SYSVRF 280 AIR EVO HR R +
SYSVRF 335 AIR EVO HR R +
SYSVRF 450 AIR EVO HR R x2
SYSVRF JOINT
OUT 04 HR
64
158/176,5
SYSVRF 1580 AIR EVO HR R
SYSVRF 280 AIR EVO HR R +
SYSVRF 400 AIR EVO HR R +
SYSVRF 450 AIR EVO HR R x2
SYSVRF JOINT
OUT 04 HR
64
165/185
SYSVRF 1650 AIR EVO HR R
SYSVRF 400 AIR EVO HR R x3
+ SYSVRF 450 AIR EVO HR R
SYSVRF JOINT
OUT 04 HR
64
170/190
SYSVRF 1700 AIR EVO HR R
SYSVRF 400 AIR EVO HR R x2
+ SYSVRF 450 AIR EVO HR R x2
SYSVRF JOINT
OUT 04 HR
64
175/195
SYSVRF 1750 AIR EVO HR R
SYSVRF 400 AIR EVO HR R +
SYSVRF 450 AIR EVO HR R x3
SYSVRF JOINT
OUT 04 HR
64
180/200
SYSVRF 1800 AIR EVO HR R
SYSVRF 450 AIR EVO HR R x4
SYSVRF JOINT
OUT 04 HR
64
55
| VRF Heat Pump water-cooled
Modular VRF Heat Pump Units
SYSVRF WATER EVO HP
Features
Water-cooled VRF with DC Inverter compressor
and pipe-in-pipe heat exchanger.
Compact size and long piping system.
High efficiency at partial load.
Inverter Scroll compressor providing wide capacity
output from 10% to 100% evenly.
Centralized control, BMS connection and web access
potential.
Pipe-in-pipe heat exchanger assures excellent
performance in heat trasfer and outstanding reliability.
Piping connection in four different directions makes
simple the installation of outdoor unit.
Maximum 59 indoor units connection (100 kW modules).
Indoor unit combination total capacity index from 50%
to 130%.
Dimensions
780
550
1000
30
620
20
112 70 64
50
52
444
52
326.5
61.5
152
95
32
45
55
176.5
52
198
56
VRF Heat Pump water-cooled |
Technical features
Model Indoor unit
SYSVRF
252 WATER EVO HP R
280 WATER EVO HP R
335 WATER EVO HP R
314247
314248
314249
Art. no.
Power Supply
V/Ph/Hz
380-415/3/50
Cooling capacity
kW
25,2
28,0
33,5
Power Input
kW
4,80
6,10
8,00
5,25
4,59
4,19
Heating capacity
kW
27,0
31,5
37,5
Power Input
kW
EER
COP
Compressor
Inverter Scroll
Quantity
7,80
4,81
pcs
1
W
40-80
40-80
40-80
Refrigerant oil
ml
500
500
500
m3/h
5,4
6,0
7,2
kPa
35
40
48
dB(A)
51
52
52
kg
2,0
Pressure drop
Sound pressure level
Type
R410A
Refrigerant charge
Dimension LxWxH
mm
Packing LxWxH
mm
Net/gross weight
Piping dimension
5,83
5,40
Crankcase heater
Water flow
Refrigerant
4,45
6,07
2,0
2,0
780x1.000x550
845x1.170x600
kg
140/155
147/156
Liquid pipe
mm (in)
9,53 (3/8”)
9,53 (3/8”)
12,7 (1/2”)
Gas pipe
mm (in)
22,2 (7/8”)
22,2 (7/8”)
25,4 (1”)
Oil balance pipe
mm (in)
Water side pipe
mm
Max qty. indoor units connection
146/155
6,35 (1/4”)
31,8
pcs
13
16
20
Nominal conditions
Indoor unit
Module water inlet
Piping lenght
Level difference
Cooling mode
27°C DB, 19°C WB
30°C DB
5m
0m
Heating mode
20°C DB, 19°C WB
20°C DB
5m
0m
The sound pressure value may vary depending on ambient conditions.
Piping Lenght
Maximum piping equivalent lenght.
100 m
Maximum piping (the farthest IDU from the first indoor unit
branch) equivalent lenght.
Maximum outdoor unit-indoor unit drop height.
30 m
Maximum indoor unit to indoor unit drop height.
20 m
Modules SYSVRF WATER EVO HP
Permitted value
Total piping lenght (actual)
Piping lenght
Maximum piping
300 m
Actual lenght
120 m
Equivavent lenght
150 m
Piping (the farthest IDU from the first indoor unit branch)
equivalent lenght
Drop height
8m
Module indoor unit drop height
Indoor unit to indoor unit drop height
40 m
Module up
50 m
Module down
40 m
30 m
57
58
| VRF water-cooled combination
Unit combination SYSVRF WATER EVO HP
Design
Cooling/
Heating
capacity kW
Model
Recommended
combination
Outdoor
branch
Max.
indoor
unit qty
25,2/27
SYSVRF 252 WATER EVO
HP R
SYSVRF 252 WATER EVO HP R
-
13
28/31,5
SYSVRF 280 WATER EVO
HP R
SYSVRF 280 WATER EVO HP R
-
16
33,5/37,5
SYSVRF 335 WATER EVO
HP R
SYSVRF 335 WATER EVO HP R
-
20
50,4/54
SYSVRF 504 WATER EVO
HP R
SYSVRF 252 WATER EVO HP R x2
SYSVRF JOINT
OUT 02 HP
26
53,2/58,5
SYSVRF 532 WATER EVO
HP R
SYSVRF 252 WATER EVO HP R
+ SYSVRF 280 WATER EVO HP R
SYSVRF JOINT
OUT 02 HP
29
56/63
SYSVRF 560 WATER EVO
HP R
SYSVRF 280 WATER EVO HP R x2
SYSVRF JOINT
OUT 02 HP
33
61,5/69
SYSVRF 615 WATER EVO
HP R
SYSVRF 280 WATER EVO HP R
+ SYSVRF 335 WATER EVO HP R
SYSVRF JOINT
OUT 02 HP
36
67/75
SYSVRF 670 WATER EVO
HP R
SYSVRF 335 WATER EVO HP R x2
SYSVRF JOINT
OUT 02 HP
39
VRF water-cooled combination |
Design
Cooling/
Heating
capacity kW
Model
Recommended
combination
Outdoor
branch
Max.
indoor
unit qty
78,4/85,5
SYSVRF 784 WATER EVO
HP R
SYSVRF 232 WATER EVO HP R x2
+ SYSVRF 280 WATER EVO HR R
SYSVRF JOINT
OUT 03 HP
43
81,2/90
SYSVRF 812 WATER EVO
HP R
SYSVRF 252 WATER EVO HP R
+ SYSVRF 280 WATER EVO HP
R x2
SYSVRF JOINT
OUT 03 HP
46
84/94,5
SYSVRF 840 WATER EVO
HP R
SYSVRF 280 WATER EVO HP R x3
SYSVRF JOINT
OUT 03 HP
50
89,5/100,5
SYSVRF 895 WATER EVO
HP R
SYSVRF 280 WATER EVO HP R x2
+ SYSVRF 335 WATER EVO HP R
SYSVRF JOINT
OUT 03 HP
53
95/106,5
SYSVRF 950 WATER EVO
HP R
SYSVRF 280 WATER EVO HP R +
SYSVRF 335 WATER EVO HP R x2
SYSVRF JOINT
OUT 03 HP
56
100,5/112,5
SYSVRF 1005 WATER EVO
HP R
SYSVRF 335 WATER EVO HP R x3
SYSVRF JOINT
OUT 03 HP
59
59
| VRF Wall indoor units
Wall-Mounted Indoor Units
SYSVRF WALL
Features
Front panel of modern design that fits into any
interior decor.
Even and smooth air distribution due to auto swing
function.
Multi-refrigerant outlet pipe method: left/right/rear,
more flexible for installation.
Washable air filter, easy for insertion and removal.
Built-in electronic expansion valve (EXV) ensuring
precise flow control.
Infrared receiver and remote SYSCONTROL RM 02
with address setting function as standard equipment.
Wired
controller
SYSCONTROL
WC 90
(optional)
Infrared remote
control
SYSCONTROL
RM 02
(standard)
Accessories/option
Wired controller SYSCONTROL WC 90 with address
setting function for heat pump system.
Wired controller SYSCONTROL WC 120 for heat
recovery system.
Wired
controller
SYSCONTROL
WC 120
(optional)
Dimensions
B
60
A
C
Indoor unit SYSVRF
WALL 15 Q
WALL 22 Q
WALL 28 Q
WALL 36 Q
WALL 45 Q
WALL 56 Q
A
mm
915
1.072
B
mm
290
315
C
mm
230
230
VRF Wall indoor units |
Technical features
Model Indoor unit
SYSVRF
Art. no.
Power Supply
WALL 15 Q
WALL 22 Q
WALL 28 Q
WALL 36 Q
WALL 45 Q
WALL 56 Q
314123
314124
314125
314126
314127
314128
V/Ph/Hz
Cooling capacity
kW
Power Input
220-240/1/50
1,5
2,2
2,8
W
Current
A
Heating capacity
kW
Power Input
Current
A
m3/h
Sound pressure level (hi/med/low)
4,5
5,6
45
0,14
1,7
0,20
2,4
3,2
W
Air flow (hi/med/low)
3,6
28
4,0
0,33
5,0
6,3
28
45
0,14
0,20
525/480/430
590/520/480 860/755/830 925/860/755
35/32/29
40/38/34
Dimension (LxWxH)
dB(A)
mm
915x230x290
1.072x230x315
Packing (LxWxH)
mm
1.020x315x390
1.180x315x415
Net/gross weight
kg
13/16,5
15,1/18,8
Refrigerant
Piping dimension
R410A
Liquid pipe
mm (in)
6,4 (1/4”)
9,5 (1/4”)
Gas pipe
mm (in)
12,7 (1/2”)
15,9 (5/8”)
Drain piping
Operating ambient temp. range
mm
16,5
°C
Cooling +17...+32 / Heating +10...+28
Nominal conditions
Indoor unit
Outdoor unit
Piping lenght
Level difference
Cooling mode
27°C DB, 19°C WB
35°C DB
8m
0m
Heating mode
20°C DB, 15°C WB
7°C
8m
0m
The sound pressure value may vary depending on ambient conditions.
61
| VRF Compact Cassette indoor units
Compact Cassette Indoor Units
SYSVRF CASSETTE MINI
Features
New grille SYSPANEL CASSETTE MINI VRF with 360°
air discharge providing strong circulating air flow
to cool or heat every corner of the room.
Compact casing making it match perfectly with
ambient decoration.
Advanced 3D spiral fan design reducing the air
resistance and operation noise.
Integrated drain pump with a head of 500 mm.
Fresh air hole and reserved ports for duct connection.
Built-in electronic expansion valve (EXV) ensuring
precise flow control.
Infrared receiver and remote SYSCONTROL RM 02
with address setting function as standard equipment.
Connecting points of refrigerant pipe (gas/liquid side)
Drain point
Wired
controller
SYSCONTROL
WC 120
(optional)
647 (panel)
Wired controller SYSCONTROL WC 90 with address
setting function for heat pump system.
Wired controller SYSCONTROL WC 120 for heat
recovery system.
570
Accessories/option
Wired
controller
SYSCONTROL
WC 90
(optional)
523
60
Infrared remote
control
SYSCONTROL
RM 02
(standard)
545
Dimensions
570
647 (panel)
Connecting points of refrigerant pipe (gas/liquid side)
Drain point
545
570
647 (panel)
Hook
Main body
Nut
Ceiling
260
647 (panel)
570
523
60
62
50
600
Panel
VRF Compact Cassette indoor units |
Technical features
SYSVRF
CASSETTE MINI
22 Q
CASSETTE MINI
28 Q
CASSETTE MINI
36 Q
CASSETTE MINI
45 Q
CASSETTE MINI
56 Q
SYSPANEL
CASSETTE MINI
VRF
CASSETTE MINI
VRF
CASSETTE MINI
VRF
CASSETTE MINI
VRF
CASSETTE MINI
VRF
Art. no. Indoor unit
314095
314096
314097
314098
314099
Art. no. Panel unit
313324
313324
313324
313324
313324
4,5
5,6
Model Indoor unit
Model Panel unit
Power Supply
V/Ph/Hz
Cooling capacity
Power Input
Current
2,2
2,8
W
48
48
kW
Power Input
W
Current
A
Air flow (hi/med/low)
Sound pressure level (hi/med/low)
Panel
kW
A
Heating capacity
Unit
220-240/1/50
3,6
56
0,175
2,4
0,21
3,2
4,0
0,175
0,21
m3/h
522/414/313
610/521/409
dB(A)
35,8/33,4/23,4
Dimension (LxWxH)
mm
Packing (LxWxH)
mm
Net/gross weight
kg
6,0
56
41,5/35,6/28,8
570x570x260
675x675x285
17,5/22
19/23,5
Dimension (LxWxH)
mm
647x675x50
Packing (LxWxH)
mm
705x705x113
Net/gross weight
kg
3/5
Refrigerant
Piping dimension
5,0
48
R410A
Liquid pipe
mm (in)
6,4 (1/4”)
9,5 (3,8”)
Gas pipe
mm (in)
12,7 (1/2”)
15,9 (5/8”)
Drain piping
Operating ambient temp. range
mm
25
°C
Cooling +17...+32 / Heating +10...+28
Nominal conditions
Indoor unit
Outdoor unit
Piping lenght
Level difference
Cooling mode
27°C DB, 19°C WB
35°C DB
8m
0m
Heating mode
20°C DB, 15°C WB
7°C
8m
0m
The sound pressure value may vary depending on ambient conditions.
63
| VRF Cassette indoor units
Standard Cassette Indoor Units
SYSVRF CASSETTE
Features
Wired
controller
SYSCONTROL
WC 90
(optional)
Infrared remote
control
SYSCONTROL
RM 02
(standard)
Accessories/option
Wired controller SYSCONTROL WC 90 with address
setting function for heat pump system.
Wired controller SYSCONTROL WC 120 for heat
recovery system.
Wired
controller
SYSCONTROL
WC 120
(optional)
950
780
105 Φ
ou
A
950
680
55
840
New grille SYSPANEL CASSETTE EVO with 360° air
discharge providing strong circulating air flow to cool
or heat every corner of the room.
Ultra-thin casing for easy installation into a shallow
ceiling.
Advanced 3D spiral fan design reducing the air
resistance and operation noise.
Models 90, 112 and 140 equipped with high efficient
DC fan motor.
Integrated drain pump with a head of 750 mm.
Fresh air hole and reserved ports for duct connection.
Built-in electronic expansion valve (EXV) ensuring
precise flow control.
Infrared receiver and remote SYSCONTROL RM 02
with address setting function as standard equipment.
Dimensions
950
780
105 Φ32 Drain pipe
outter diameter
A
B
70
Φ75 New air
supply orifice
≥20
146
840
55
950
680
Ceiling
B
CASSETTE
28 Q
Indoor unit SYSVRF
840
904
Φ75 New air
supply orifice
CASSETTE
≥20
36 Q
CASSETTE
45 Q
CASSETTE
56 Q
CASSETTE
71 Q
46
Panel
Main body
CASSETTE
90 Q
CASSETTE
112 Q
A
mm
230
230
300
B
mm
170
170
190
Ceiling
Panel
Main body
146
64
46
CASSETTE
140 Q
VRF Cassette indoor units |
Technical features
Model Indoor unit
Model Panel unit
SYSVRF
CASSETTE CASSETTE CASSETTE CASSETTE CASSETTE CASSETTE CASSETTE CASSETTE
28 Q
36 Q
45 Q
56 Q
71 Q
90 Q
112 Q
140 Q
SYSPANEL
CASSETTE CASSETTE CASSETTE CASSETTE CASSETTE CASSETTE CASSETTE CASSETTE
EVO VRF EVO VRF EVO VRF EVO VRF EVO VRF EVO VRF EVO VRF EVO VRF
Art. no. Indoor unit
314100
314101
313325
314102
314103
314255
314256
314257
Art. no. Panel unit
313728
313728
313728
313728
313728
313728
313728
313728
14,0
Power Supply
V/Ph/Hz
Cooling capacity
kW
Power Input
W
Current
A
Heating capacity
kW
Power Input
W
Current
A
m3/h
Air flow (hi/med/low)
Sound pressure level (hi/med/low)
Unit
Panel
220-240/1/50
2,8
3,6
80
mm
Packing (LxWxH)
mm
Net/gross weight
kg
5,6
7,1
9,0
11,2
90
75
82
125
125
0,40
3,2
4,0
80
0,50
847/766/640
6,3
8,0
10,0
12,5
75
82
125
125
42/38/35
135
0,70
0,80
1.157/
955/749
1.540/1.300/1.120
1.800/
1.500/
1.280
45/42/39
47/41/36
50/45/35
840x840x300
955x955x247
24/28
15,0
0,50
840x840x230
955x955x317
26/30
32/37
Dimension (LxWxH)
mm
950x950x46
Packing (LxWxH)
mm
1.000x1.000x60
Net/gross weight
kg
6/8
Refrigerant
Piping dimension
0,80
90
864/755/658
135
0,70
5,0
0,40
dB(A)
Dimension (LxWxH)
4,5
R410A
Liquid pipe
mm (in)
6,4 (1/4”)
9,5 (3/8”)
Gas pipe
mm (in)
12,7 (1/2”)
15,9 (5/8”)
Drain piping
Operating ambient temp. range
mm
32
°C
Cooling +17...+32 / Heating +10...+28
Nominal conditions
Indoor unit
Outdoor unit
Piping lenght
Level difference
Cooling mode
27°C DB, 19°C WB
35°C DB
8m
0m
Heating mode
20°C DB, 15°C WB
7°C
8m
0m
The sound pressure value may vary depending on ambient conditions.
65
66
| VRF Cassette 1way indoor units
Cassette 1Way Indoor Unit
SYSVRF CASSETTE 1W
Features
Stylish look with new decorative panel.
Ultra-thin chassis for easy installation in false ceiling.
Integrated drain pump with a head of 750mm.
Built-in electronic expansion valve (EXV) ensuring
precise flow control.
Infrared receiver and remote controller SYSCONTROL
RM 02. With address setting function as standard
equipment.
Accessories/option
Wired controller SYSCONTROL WC 90 with address
setting function for heat pump system.
Wired controller SYSCONTROL WC 120 for heat
recovery system.
Infrared remote
control
SYSCONTROL
RM 02
(standard)
Wired
controller
SYSCONTROL
WC 120
(optional)
Dimensions
1015
Wired
controller
SYSCONTROL
WC 90
(optional)
290
VRF Cassette 1way indoor units |
Technical features
Model Indoor unit
SYSVRF
Model Panel unit
SYSPANEL
Art. no. Indoor unit
CASSETTE
1W 18 Q
CASSETTE
1W 22 Q
CASSETTE
1W 28 Q
CASSETTE
1W 36 Q
CASSETTE 1W VRF
CASSETTE 1W VRF
CASSETTE 1W VRF
CASSETTE 1W VRF
314213
314214
314215
314216
2,8
3,6
Art. no. Panel unit
314217
Power Supply
V/Ph/Hz
Cooling capacity
kW
Power Input
Current
41
A
kW
Power Input
0,24
0,25
2,2
2,6
3,2
W
Current
A
m3/h
Air flow (hi/med/low)
Sound pressure level (hi/med/low)
Panel
2,2
W
Heating capacity
Unit
220-240/1/50
1,8
dB(A)
0,24
0,25
523/404/275
573/456/315
39/37/34
40/38/34
Dimension (LxWxH)
mm
1.054×425×169
1.054×425×169
Packing (LxWxH)
mm
1.155×490×245
1.155×490×245
Net/gross weight
kg
12,5/16
13/16,5
Dimension (LxWxH)
mm
1.180×465×36.5
1.180×465×36.5
Packing (LxWxH)
mm
1.232×517×107
1.232×517×107
Net/gross weight
kg
3,5/5,2
9/12
Refrigerant
Piping dimension
4,0
41
R410A
Liquid pipe
mm (in)
6,4 (1/4”)
Gas pipe
mm (in)
12,7 (1/2”)
Drain piping
Operating ambient temp. range
mm
25
°C
Cooling +17...+32 / Heating +10...+28
Nominal conditions
Indoor unit
Outdoor unit
Piping lenght
Level difference
Cooling mode
27°C DB, 19°C WB
35°C DB
8m
0m
Heating mode
20°C DB, 15°C WB
7°C
8m
0m
The sound pressure value may vary depending on ambient conditions.
67
| VRF Cassette 2way indoor units
Cassette 2Way Indoor Unit
SYSVRF CASSETTE 2W
Features
Stylish look with new decorative panel.
Slim casing for easy installation in narrow ceiling.
Integrated drain pump with a head of 750mm.
Built-in electronic expansion valve (EXV) ensuring
precise flow control.
Infrared receiver and remote controller SYSCONTROL
RM 02. With address setting function as standard
equipment.
Wired
controller
SYSCONTROL
WC 90
(optional)
Infrared remote
control
SYSCONTROL
RM 02
(standard)
Accessories/option
Wired controller SYSCONTROL WC 90 with address
setting function for heat pump system.
Wired controller SYSCONTROL WC 120 for heat
recovery system.
Wired
controller
SYSCONTROL
WC 120
(optional)
Dimensions
591
436
129 129
701
1430
44
104
91
171
91
299
176
192
120
42~45
Φ 32
51
44
45
151
Φ160
299
117
Φ 32
257
241
185
1172
57
Fresh air
connector
Φ
12
5
680
The panel contour dimension 1430
20
20
Machine body size 1172
701
129
44
151
Hanging screw
bolts distance 520
20
Machine body
size 591
The ceiling opening
dimension 640
20
The ceiling opening dimension 1390
Hanging screw bolts distance 1207
The ceiling opening (1390*640)
The panel contour
dimension 680
68
VRF Cassette 2way indoor units |
Technical features
Model Indoor unit
Model Panel unit
SYSVRF
CASSETTE
2W 22 Q
CASSETTE
2W 28 Q
CASSETTE
2W 36 Q
CASSETTE
2W 45 Q
CASSETTE
2W 56 Q
SYSPANEL
CASSETTE
2W VRF
CASSETTE
2W VRF
CASSETTE
2W VRF
CASSETTE
2W VRF
CASSETTE
2W VRF
314218
314219
314220
314221
314222
Art. no. Indoor unit
Art. no. Panel unit
314224
Power Supply
V/Ph/Hz
Cooling capacity
kW
Power Input
Current
41
A
Power Input
Current
0,35
7,1
92
108
0,45
0,55
3,2
4,0
5,0
6,3
W
57
60
92
108
154
dB(A)
Dimension (LxWxH)
mm
Packing (LxWxH)
mm
Net/gross weight
kg
0,35
0,45
654/530/410
725/591/458
33/29/24
0,55
850/670/550
36/32/29
980/800/670
39/35/30
1.172×425×169
1.355×675×400
34/42,5
36/44,5
Dimension (LxWxH)
mm
1.430x680x299
Packing (LxWxH)
mm
1.525x765x130
Net/gross weight
kg
10,5/15
Refrigerant
Piping dimension
5,6
60
2,6
A
Sound pressure level (hi/med/low)
4,5
kW
m3/h
Air flow (hi/med/low)
Panel
3,6
W
Heating capacity
Unit
220-240/1/50
2,2
R410A
Liquid pipe
mm (in)
6,4 (1/4”)
9,5 (3/8”)
Gas pipe
mm (in)
12,7 (1/2”)
15,9 (5/8”)
Drain piping
Operating ambient temp. range
mm
32
°C
Cooling +17...+32 / Heating +10...+28
Nominal conditions
Indoor unit
Outdoor unit
Piping lenght
Level difference
Cooling mode
27°C DB, 19°C WB
35°C DB
8m
0m
Heating mode
20°C DB, 15°C WB
7°C
8m
0m
The sound pressure value may vary depending on ambient conditions.
69
| VRF Ceiling/Floor indoor units
Ceiling and Floor Indoor Units
SYSVRF CEILING
Features
995
906,5
371
Infrared remote
198,2
control
SYSCONTROL
RM 02
(standard)
35
39,5
98
133,5
175
401
655
200
207
Flexible vertical or horizontal installation, even into a
corner of the ceiling.
Even and smooth air distribution due to auto horizontal
and auto vertical swing function.
Models 90,112 and 140 equipped with high efficient
DC fan motor.
Wide angle air flow.
Low noise operation.
Washable air filter, easy for insertion and removal.
Built-in electronic expansion valve (EXV) ensuring
precise flow control.
Infrared receiver and remote SYSCONTROL RM 02
with address setting function as standard equipment.
Wired
controller
SYSCONTROL
WC 90
(optional)
Wired
controller
SYSCONTROL
WC198,2
120
(optional)
1284,5
1194,5
547
515
39,5
37
Wired controller SYSCONTROL WC 120 for heat
recovery system.
655
Wired controller SYSCONTROL WC 90 with address
setting function for heat pump system.
200
98
133,5
175
Accessories/option
Dimensions
SYSVRF CEILING 36/45/56/71
Q
995
SYSVRF CEILING 112/140 Q
906,5
35
39,5
198,2
198,2
198,2
39,5
37
1670
1542,3
724,5
630,5
198,2
655
200
98
133,5
175
200
39,5
37
655
515
98
133,5
175
547
515
235
112,5
144
184,5
255,2
655
1284,5
1194,5
1284,5
1194,5
630,5
675
200
SYSVRF CEILING 90 Q
547
1670
1542,3
724,5
69,5
655
371
35
39,5
98
133,5
175
200
401
371
207
906,5
98
133,5
175
995
401
207
70
VRF Ceiling/Floor indoor units |
Technical features
Model Indoor unit
SYSVRF
Art. no.
Power Supply
CEILING
36 Q
CEILING
45 Q
CEILING
56 Q
314116
314117
314118
V/Ph/Hz
Cooling capacity
Power Input
Current
CEILING
71 Q
CEILING
90 Q
CEILING
112 Q
CEILING
140 Q
314119
314282
314283
314284
11,2
220-240/1/50
kW
3,6
4,5
5,6
7,1
9,0
W
49
120
122
125
126
A
0,57
0,60
kW
4,0
5,0
6,3
8,0
10,0
Power Input
W
49
120
122
125
126
65x2
Current
A
0,57
0,60
0,83
Heating capacity
Air flow (hi/med/low)
Sound pressure level (hi/med/low)
0,55
14,0
65x2
0,55
0,83
12,5
15,5
m3/h
650/
570/500
800/600/500
1.200/
900/700
1.980/1.860/1.730
dB(A)
40/38/36
43/41/38
45/43/40
47/45/42
1.670x244x680
Dimension (LxWxH)
mm
990x206x660
1.280x
206x660
Packing (LxWxH)
mm
1.089x296x744
1.379x
296x744
1.764x329x760
Net/gross weight
kg
34,5/41
54/59
26/32
28/34
Refrigerant
Piping dimension
R410A
Liquid pipe
mm (in)
6,4 (1/4”)
9,5 (3/8”)
Gas pipe
mm (in)
12,7 (1/2”)
15,9 (5/8”)
Drain piping
Operating ambient temp. range
mm
16
°C
Cooling +17...+32 / Heating +10...+28
Nominal conditions
Indoor unit
Outdoor unit
Piping lenght
Level difference
Cooling mode
27°C DB, 19°C WB
35°C DB
8m
0m
Heating mode
20°C DB, 15°C WB
7°C
8m
0m
The sound pressure value may vary depending on ambient conditions.
71
| VRF Duct indoor units
Medium Static Pressure Duct Indoor Units
SYSVRF DUCT
Features
External static pressure up to 100 Pa.
Models 90, 112 and 140 equipped with high efficient
DC fan motor.
Washable air filter placed in an aluminum frame which
is removable downward from the bottom.
Fresh air hole, air inlet/outlet flange are standard for
easy duct connection.
Air inlet from back as standard and from bottom as
optional with the same flange plate.
Integrated drain pump with a head of 750 mm.
Electronic expansion valve (EXV) fixed inside of the
indoor unit.
Std functional port such as remote on/off free contact.
Display board with infrared receiver as standard
equipment.
Wired controller SYSCONTROL WC 90 with address
setting function as standard equipment.
Wired
controller
SYSCONTROL
WC 90
(standard)
Infrared
remote control
SYSCONTROL
RM 02
(optional)
Wired
controller
SYSCONTROL
WC 120
(optional)
Accessories/option
Infrared controller SYSCONTROL RM 02 with address
setting function for heat pump system.
Wired controller SYSCONTROL WC 120 for heat
recovery system.
Dimensions
Indoor unit SYSVRF
DUCT
22 Q
DUCT
28 Q
DUCT
36 Q
DUCT
45 Q
DUCT
56 Q
mm
700
700
700
920
920
mm
210
210
210
210
210
C
mm
635
635
635
635
635
D
mm
570
570
570
570
570
B
H
A
B
I
72
F
G
A
E
E
mm
65
65
65
65
65
F
mm
493
493
493
713
713
G
mm
35
35
35
35
35
H
mm
119
119
119
119
119
A
mm
DUCT
71 Q
920
B
mm
270
270
270
300
C
mm
635
775
775
865
D
mm
570
710
710
800
E
mm
65
65
65
80
F
mm
713
933
933
993
G
mm
35
35
35
40
H
mm
179
179
179
204
Indoor unit SYSVRF
D
C
DUCT
90 Q
1.140
DUCT
112 Q
1.140
DUCT
140 Q
1.200
VRF Duct indoor units |
Technical features
Model Indoor unit
DUCT
22 Q
DUCT
28 Q
DUCT
36 Q
DUCT
45 Q
314107
314108
314109
314110
SYSVRF
Art. no.
Power Supply
V/Ph/Hz
Cooling capacity
kW
2,2
2,8
3,6
W
59
57
61
Current
A
kW
2,6
3,2
4,0
W
59
57
61
Current
A
m3/h
Sound pressure level (hi/med/low)
dB(A)
External static pressure
DUCT
90 Q
DUCT
112 Q
DUCT
140 Q
314111
314112
314261
314262
314258
14,0
4,5
0,28
Power Input
Air flow (hi/med/low)
DUCT
71 Q
220-240/1/50
Power Input
Heating capacity
DUCT
56 Q
7,1
9,0
11,2
92
5,6
149
68
200
160
0,50
0,70
1,00
1,80
1,55
15,5
5,0
8,0
10,0
12,5
92
149
68
200
160
0,28
0,50
0,70
1,00
1,80
1,55
570/410/320
958/667/583
1207/
905/821
1290/
1090/
940
1790/
1550/
1352
1950/
1600/
1400
43/38,9/36
45/
40/36
44/
38/37
47/
41/37
42/
47/38
20
(10~50)
40
40
(10~80) (10~100)
42/
38/36
40/35/32
6,3
10 (10~30)
Pa
Dimension (LxWxH)
mm
700х635х210
920х635х210
920х
635х270
1.140х775х270
1.200х
865х300
Packing (LxWxH)
mm
915х655х290
1.135х655х290
1.135х
655х350
1.355х795х350
1.385х
920х375
Net/gross weight
kg
27/32
30/34
40/48
49/58
21,5/26
22/27
Refrigerant
R410A
Piping dimension
Liquid pipe
mm (in)
6,4 (1/4”)
9,5 (1/4”)
Gas pipe
mm (in)
12,7 (1/2”)
15,9 (5/8”)
Drain piping
mm
Operating ambient temp. range
32
°C
Cooling +17…+32 / Heating +10…+28
Fan performance
30
30
20
20
10
50
40
40
30
30
30
20
30
20
20
10
10
Low
speed
Low
speed
Low
Low
speed
speed
Low
Low
speed speed
20
10
10
50
50
40
40
30
30
20
20
10
10
50
40
40
30
30
20
20
10
10
400200 600
400 800
600
800
200
400
600
800
280
280
280
3
3
Air 200
flow (m 3400
Air
/h) flow
(m
flow
/h)
/h)
200 Air
600
200
400(m
800
400
600 600
800 800
280
280 280
3
3
3
Air flow (m /h)
Air flowAir
(mflow
/h) (m /h)
10
420 600
50
40
30
30
20
20
10
1000
1200
1200
30
20
20
10
10
800630
800
1000 1400
1000
1200
1000
1200
630
180
160
180 180
160
160
180
160
180 180
160
160
80Super high
160
140
160 160
140
140
160
140
160 160
140
140
30
20
10
60
50
40
30
20
60
50
40
30
20
10
10
70
60
50
40
30
20
10
770800
70
60
50
40
30
20
10
Super highSuper high
speed
speed
speed
Super high
Super high
Super high
70 speed
speed speed
60
50
40
30
High
speed
High
speed
Medium
speed
Medium
Low
speed
speed
Low
speed
High
High
speed
speed
High
High
speed speed
Medium Medium
speed
speed
Medium Medium
Low
Low
speed speed
speed
speed
Low
Low
speed speed
20
10
1000
800 770
1200
800
1000 1400
1000
1200
770
140
120
120
100
100
80
60
40
20
80
60
40
20
1200
1400
1400
3
Air
/h)
flow
Air
(m 31400
flow
/h)
(m 3/h)
1000
800
1200
800
1000
1000
1200
1200
1400 1400
770800Air flow
770(m
770
3
Air flow (m 3/h)
Air flowAir
(mflow
/h) (m 3/h)
140 140
120
120
120 120
100
100
100 100
80
80
60
40
20
80
60
40
20
60
40
20
80
60
Super high
Super highSuper high
speed
speed
speed
Super high
Super high
Super high
High
High
High
speed
speed
speed
speed
speed
speed
High
High
High
speed
speed speed
Medium
speed
Medium
Low
speed
speed
Low
speed
External static pressure (Pa)
External static pressure (Pa)
40
70
80
External static pressure (Pa)
External static pressure (Pa)
50
70
External static pressure (Pa)
60
80
External static pressure (Pa)
70
80
Medium Medium
speed
speed
Medium Medium
Low
speed Low
speed
speed
speed
Low
Low
speed speed
40
140
120
120
100
100
80
60
40
20
20
80
60
40
20
1000
1400
1000 1000
1400
1800 1400
2200
1800 1800
2200 2200
1020
1020 1020
3
(m 3Air
/h)1000
flow1800
Air
(m 3flow
/h)1400
(m2200
/h)
1000Air flow1400
1000
1400
1800
18002200 2200
1020
1020 1020
3
3
3
Air flow (m /h)
Air flowAir
(mflow
/h) (m /h)
External static pressure (Pa)
External static pressure (Pa)
200 200
180
180
90
90
External static pressure (Pa)
220 220
200
200
200
180
External static pressure (Pa)
220
200
200 200
180
180
External static pressure (Pa)
External static pressure (Pa)
220 220
200
200
200
180
External static pressure (Pa)
220
200
100 100
90
90
External static pressure (Pa)
110
110
100
100
100
90
External static pressure (Pa)
External static pressure (Pa)
110
100
80
3
3
SYSVRF
DUCT
140 Q
220
220
220
110
90
1400
Air flow (m /h)
Air flowAir
(mflow
/h) (m /h)
3
110
80
1200
1400
3
3
Air 800
flow (m 3630
Air
/h) flow
Air
(m
flow
/h)
(m
/h)
1000
800
1200
800
1000
1400
1000
1200 1200
1400 1400
630
630
3
SYSVRF
DUCT 112 Q
220
220
220
40
30
10
Air flow (m /h)
Air flowAir
(mflow
/h) (m /h)
SYSVRF
DUCT 90 Q
110
3
Super highSuper high
speed
speed
speed
50 Super high
Super high
Super high
speed
speed speed
40
High
High
High
speed
speed
40 speed
High
High
High
speed
speed speed
30
Medium
Medium Medium
speed
speed
speed
30
Medium
Medium Medium
speed
speed speed
20
Low
Low
Low
speed
speed
speed
20
Low
Low
Low
speed
speed speed
10
50
630 800
3
3
Air 600
flow (m 3420
Air
/h) flow
Air
(m
flow
/h)
/h)
800
600
1000
600
800(m
1200
800
1000 1000
1200 1200
420
420
3
50Super high
40
10
800600420
1000
600
800
800 1200
1000
420
60
50
40
10
60
60
50
Super highSuper high
speed
speed
speed
50 Super high
Super high
Super high
speed
speed speed
40
High
High
High
speed
speed
40 speed
High
High
High
speed
speed speed
30
Medium
Medium Medium
speed
speed
speed
30
Medium
Medium Medium
speed
speed speed
20
Low
Low
Low
speed
speed
speed
20
Low
Low
Low
speed
speed speed
10
70
60
60
50Super high
50
80
70
70
60
60
80
80
70
70
70
60
80
80
70
60
60
60
200
External static pressure (Pa)
External static pressure (Pa)
70
60
80
80
70
External static pressure (Pa)
External static pressure (Pa)
40
External static pressure (Pa)
External static pressure (Pa)
External static pressure (Pa)
50
External static pressure (Pa)
External static pressure (Pa)
External static pressure (Pa)
50
Super high
Super highSuper high
speed
speed
speed
Super high
Super high
Super high
High
High
speed
speed High
speed
50
speed
speed
speed
High
High
High
50
speed
speed speed
Medium
Medium Medium
40
speed
speed
speed
Medium
Medium Medium
40
speed
speed speed
60
External static pressure (Pa)
External static pressure (Pa)
60
50
70
60
60
80
70
External static pressure (Pa)
60
70
SYSVRF DUCT 71 Q
80
External static pressure (Pa)
70
60
80
70
70
70
40
80
80
External static pressure (Pa)
External static pressure (Pa)
80
70
80
External static pressure (Pa)
80
70
SYSVRF DUCT 45/56 Q
80
External static pressure (Pa)
80
External static pressure (Pa)
External static pressure (Pa)
SYSVRF DUCT 22/28/36 Q
80
140 140
120
120
120 120
100
100
Super high
Super highSuper high
speed
speed
speed
Super high
Super high
Super high
High
High
High
speed
speed
speed
speed
speed
speed
High
High
High
speed
speed speed
Medium
speed
Medium
Low
speed
speed
Low
speed
100 100
80
80
60
40
20
80
60
40
20
60
40
20
80
60
Medium Medium
speed
speed
Medium Medium
Low
speed Low
speed
speed
speed
Low
Low
speed speed
40
20
1000
1400
1800 1400
2200
1800 1800
2200 2200
10601000 10601400
10601000
3
3
3
Air flow
(m
Air
/h)
flow
Air
(m
flow
/h) (m
/h)
1400
1000
1000
1800
1400
1400
2200
1800 18002200 2200
10601000
1060
1060
3
Air flow (m 3/h)
Air flowAir
(mflow
/h) (m 3/h)
Nominal conditions
Indoor unit
Outdoor unit
Piping lenght
Level difference
Cooling mode
27°C DB, 19°C WB
35°C DB
8m
0m
Heating mode
20°C DB, 15°C WB
7°C
8m
0m
The sound pressure value may vary depending on ambient conditions.
73
| VRF Duct HP indoor units
High Static Pressure Duct Indoor Units
SYSVRF DUCT HP
Features
External static pressure up to 250 Pa.
Washable air filter placed in an aluminum frame which
is removable downward from the bottom. Easy access
both in rear and bottom.
Fresh air hole, air inlet/outlet flange are standard for
easy duct connection.
Electronic expansion valve (EXV) fixed inside of the
indoor unit.
Display board with infrared receiver as standard
equipment.
Wired controller SYSCONTROL WC 90 with address
setting function as standard equipment.
Wired
controller
SYSCONTROL
WC 90
(standard)
Accessories/option
Infrared
remote control
SYSCONTROL
RM 02
(optional)
Wired
controller
SYSCONTROL
WC 120
(optional)
Infrared remote SYSCONTROL RM 02 with address
setting function for heat pump system.
Wired controller SYSCONTROL WC 120 for heat
recovery system.
Dimensions
135
60
96
930
88
82
343
29
86
82
270
420
249
Plastic
cover
Plastic
cover
Electrical
control box
SYSVRF DUCT HP 200/280 Q
936
75
Electrical
control box
200
378
343
60
96
1121
24
46
68
50
952
856
85
214
75
1121
SYSVRF DUCT HP 140 Q
56
SYSVRF DUCT HP 71/112 Q
420
74
VRF Duct HP indoor units |
Technical features
Model Indoor unit
SYSVRF
Art. no.
Power Supply
DUCT HP 71 Q
DUCT HP 112 Q
DUCT HP 140 Q
DUCT HP 200 Q
DUCT HP 280 Q
314129
314130
314131
314132
314133
V/Ph/Hz
Cooling capacity
220-240/1/50
kW
7,1
11,2
14,0
20,0
28,0
W
263
524
724
1.516
1.516
Power Input
Current
A
1,1
2,3
2,7
6,6
6,6
kW
8,0
12,5
16,0
22,5
31,5
Power Input
W
263
524
724
1.516
1.516
Current
A
1,1
2,3
2,7
6,6
6,6
1.510/
1.399/1.236
2.117/
1.950/1.644
2.988/
2.670/2.229
4.268/
3.780/3.200
4.400/
3.700/3.200
Heating capacity
m /h
Air flow (hi/med/low)
3
Sound pressure level (hi/med/low)
External static pressure
dB(A)
Pa
48/46/44
52/49/47
53/50/48
59/55/52
59/55/52
40 (30~196)
50 (30~196)
50 (30~196)
140 (50~250)
160 (50~250)
Dimension (LxWxH)
mm
856x690x420
856x690x420
1.200x600x400
1.356x763x470
1.356x763x470
Packing (LxWxH)
mm
1.090x768x440
1.090x768x440
1.436x768x450
1.509x964x570
1.509x964x570
Net/gross weight
kg
45/50
50,6/56
68/70
115/129
115/129
Refrigerant
R410A
Piping dimension
Liquid pipe
mm (in)
9,5 (3/8”)
9,5 (3/8”)
9,5 (3/8”)
9,5 (3/8”) (x2)
9,5 (3/8”) (x2)
Gas pipe
mm (in)
15,9 (5/8”)
15,9 (5/8”)
15,9 (5/8”)
15,9 (5/8”) (x2)
15,9 (5/8”) (x2)
32
32
32
32
32
Drain piping
mm
Operating ambient temp. range
°C
Cooling +17…+32 / Heating +10…+28
Fan performance
SYSVRF DUCT HP 112 Q
P(Pa)
P(Pa)
SYSVRF DUCT HP 71 Q
300
300
280
280
260
260
240
240
220
220
200
200
180
180
140
120
100
80
60
High speed
160
High speed
140
120
Midium speed
Midium speed
100
80
Low speed
Low speed
60
40
40
20
20
0
800 1000 1200 1400
1600 1800 2000
0
Q(m3/h)
SYSVRF DUCT HP 280 Q
P(Pa)
SYSVRF DUCT HP 200 Q
300
300
280
280
260
260
240
240
220
220
200
200
180
180
160
160
High speed
800 1000 1200 1400 1600 1800 2000 2200
Q(m3/h)
P(Pa)
SYSVRF DUCT HP 140 Q
400 600
P(Pa)
160
300
280
260
High speed
200
Midium speed
120
120
100
100
80
80
60
60
40
40
40
20
20
100
Midium speed
80
Low speed
60
0
0
400 600
800 1000 1200 1400
1600 1800 2000
Q(m3/h)
Low speed
160
140
120
Midium speed
180
Low speed
140
140
High speed
240
220
20
0
2000 2500 3000 3500 4000 4500 5000 5500 6000
2000 2500 3000 3500 4000 4500 5000 5500 6000
Q(m3/h)
Q(m3/h)
Nominal conditions
Indoor unit
Outdoor unit
Piping lenght
Level difference
Cooling mode
27°C DB, 19°C WB
35°C DB
8m
0m
Heating mode
20°C DB, 15°C WB
7°C DB
8m
0m
The sound pressure value may vary depending on ambient conditions.
75
| Exposed floor indoor unit
Exposed floor indoor unit
SYSVRF FLOOR EB
Features
With 22cm of depth and 63cm of height, the unit
perfectly fits any interior design.
Models 71 and 80 are equipped with high efficient
DC fan motor.
Washable air filter included.
Built-in electronic expansion valve (EXV) ensuring
precise flow control.
Infrared receiver and remote controller SYSCONTROL
RM 02 with address setting function as standard
equipment.
Wired
controller
SYSCONTROL
WC 90
(optional)
Infrared remote
control
SYSCONTROL
RM 02
(standard)
Accessories/option
Wired controller SYSCONTROL WC 90 with address
setting function for heat pump system.
Wired controller SYSCONTROL WC 120 for heat
recovery system.
Wired
controller
SYSCONTROL
WC 120
(optional)
Dimensions
Mounting
hole, 4
A
B
I
4xФ11
4xФ18
EXV
G
D
Gas side connector
Liquid side connector
H
F
E
C
76
J
Indoor unit SYSVRF
FLOOR EB 22 Q
FLOOR EB 28 Q
Air inlet
grille
FLOOR EB 36 Q
FLOOR EB 45 Q
A
mm
1.000
1.200
B
mm
725
925
C
mm
D
mm
E
mm
284
F
mm
232
G
mm
H
mm
I
mm
220
J
mm
150
FLOOR EB 56 Q
FLOOR EB 71 Q
1.500
1.225
672
592
310
258
345
94
100
100
FLOOR EB 80 Q
Exposed floor indoor unit |
Technical features
Model Indoor unit
SYSVRF
Art. no.
Power Supply
FLOOR EB
22 Q
FLOOR EB
28 Q
FLOOR EB
30 Q
314225
314226
314227
V/Ph/Hz
Cooling capacity
Power Input
Current
FLOOR EB
45 Q
FLOOR EB
56 Q
FLOOR EB
71 Q
FLOOR EB
80 Q
314228
314229
314285
314286
4,5
5,6
7,1
49
88
220-240/50/1
kW
2,2
W
40
2,8
3,6
46
8,0
130
A
0,18
0,21
0,22
0,22
0,4
0,56
kW
2,6
3,2
4,0
5,0
6,3
8,0
Power Input
W
40
49
88
Current
A
Heating capacity
m3/h
Air flow (hi/med/low)
Sound pressure level (hi/med/low)
External static pressure
dB(A)
46
0,18
0,21
0,22
0,22
0,4
569/
485/421
624/
522/375
660/
542/440
1.150/
970/830
1.380/1.100/870
36/33/29
37/34/30
37/34/30
41/35/31
44/39/33
1.200×
625×220
0,56
0,59
1.500×
625×220
1.500×625×220
1.682×683×312
12
Pa
Dimension (LxWxH)
mm
1.000×625×220
Packing (LxWxH)
mm
1.182×683×312
1.382×
683×312
1.382×
683×312
1.682×
683×312
Net/gross weight
kg
30/38
35,5/41
35,5/41
42/51
Refrigerant
Drain piping
9,0
130
530/
456/400
1.200×
625×220
Piping dimension
0,59
42/51
44/53
R410A
Liquid pipe
mm (in)
6,35
6,35
9,53
9,53
Gas pipe
mm (in)
12,7
12,7
15,9
16
mm
16
Nominal conditions
Indoor unit
Outdoor unit
Piping lenght
Level difference
Cooling mode
27°C DB, 19°C WB
35°C DB
8m
0m
Heating mode
20°C DB, 15°C WB
7°C DB
8m
0m
The sound pressure value may vary depending on ambient conditions.
77
| Concealed floor indoor unit
Concealed floor indoor unit
SYSVRF FLOOR CB
Features
With only 21cm thick, the unit can be easily hidden
in narrow space.
Models 71 and 80 are equipped with high efficient
DC fan motor.
Washable air filter included.
Built-in electronic expansion valve (EXV) ensuring
precise flow control.
Infrared receiver and remote controller SYSCONTROL
RM 02 with address setting function as standard
equipment.
Wired
controller
SYSCONTROL
WC 90
(optional)
Infrared remote
control
SYSCONTROL
RM 02
(standard)
Accessories/option
Wired controller SYSCONTROL WC 90 with address
setting function for heat pump system.
Wired controller SYSCONTROL WC 120 for heat
recovery system.
Wired
controller
SYSCONTROL
WC 120
(optional)
Dimensions
Connecting point
of refrigerant pipe
(Liquid side ΦA)
544
345
Connecting point
of refrigerant pipe
(Gas side ΦB)
177
78
212
C
A
B
C
FLOOR CB 22
MODEL
mm
6,4
12,7
725
FLOOR CB 28
mm
6,4
12,7
725
FLOOR CB 36
mm
6,4
12,7
925
FLOOR CB 45
mm
6,4
12,7
925
FLOOR CB 56
mm
9,5
15,9
1.225
Concealed floor indoor unit |
Technical features
Model Indoor unit
SYSVRF
Art. no.
Power Supply
FLOOR CB
22 Q
FLOOR CB
28 Q
FLOOR CB
36 Q
314232
314233
314234
V/Ph/Hz
Cooling capacity
Power Input
Current
FLOOR CB
45 Q
FLOOR CB
56 Q
FLOOR CB
71 Q
FLOOR CB
80 Q
314235
314236
314287
314288
4,5
5,6
7,1
49
88
220-240/50/1
kW
2,2
W
40
2,8
3,6
46
8,0
130
A
0,18
0,21
0,22
0,22
0,4
0,56
kW
2,6
3,2
4,0
5,0
6,3
8,0
Power Input
W
40
49
88
Current
A
Heating capacity
m3/h
Air flow (hi/med/low)
Sound pressure level (hi/med/low)
External static pressure
dB(A)
46
0,18
0,21
0,22
0,22
0,4
569/
485/421
624/
522/375
660/
542/440
1.150/
970/830
1.380/1.100/870
36/33/29
37/34/30
37/34/30
41/35/31
44/39/33
1.036×
544×212
0,56
0,59
1.336×
544×212
1.336×544×212
1.425×639×305
12
Pa
Dimension (LxWxH)
mm
840×544×212
Packing (LxWxH)
mm
939×639×305
1.139×
639×305
1.139×
639×305
1.425×
639×305
Net/gross weight
kg
25/27
29,5/34
29,5/34
33/39
Refrigerant
Drain piping
9,0
130
530/
456/400
1.036×
544×212
Piping dimension
0,59
33/39
36/40
R410A
Liquid pipe
mm (in)
6,35
6,35
9,53
9,53
Gas pipe
mm (in)
12,7
12,7
15,9
16
mm
16
Nominal conditions
Indoor unit
Outdoor unit
Piping lenght
Level difference
Cooling mode
27°C DB, 19°C WB
35°C DB
8m
0m
Heating mode
20°C DB, 15°C WB
7°C DB
8m
0m
The sound pressure value may vary depending on ambient conditions.
79
| VRF Heat Recovery Ventilation
Heat Recovery Ventilation Units
SYSVRF HRV
Features
Cross flow heat exchanger made of special paper for
enhanced heat exchange efficiency.
Main structure made of galvanized steel sheet.
High efficient DC fan motor assures low power consumption.
3 fan speeds available for sizes 500 m3/h and 1000
m3/h, 1 speed for size 2000 m3/h.
Temperature exchange efficiency above 65%.
Compact design and flexible installation in the false ceiling.
Different operating modes available: heat exchange,
bypass, auto, exhaust/supply mode (bypass damper not
included in the HRV 2000 R).
Insulation material guarantees quiet operation and
thermal insulation.
Thanks to the flexible control the HRV unit can be
interlocked to the operation of the VRF indoor units.
Wired controller SYSCONTROL WC 27 as standard
equipment.
SYSVRF HRV 500/1000 Q
SYSVRF HRV 2000 R
Wired
controller
SYSCONTROL
WC 27
(standard)
Dimensions
SYSVRF HRV 500/1000 Q
SYSVRF HRV 2000 R
W
L
75
1550
H
W2
C
Air exhaust
vent
By-pass Air return
system vent
Flange demension
W1
1400
L1
G
Model
SYSVRF HRV 500 Q
SYSVRF HRV 1000 Q
L
824
1.116
L1
754
1.045
W
904
1.134
W1
960
1.190
500
678
H
270
388
C
107
85
G
19
19
N
Φ194
Φ242
N2
111
170
350
Air supply
vent
540
700
250
120
320
1600
346
Air supply
vent
Air exhaust
vent
370
1370
Fresh
air inlet
W2
Wire
control
box
Door
326
Door
N2
300
N
Wire
control
box
20
80
Fresh
air inlet
50
1650
Air return
vent
50
VRF Heat Recovery Ventilation |
Technical features
Model Indoor unit
SYSVRF
Art. no.
Power supply
HRV 500 Q
HRV 1000 Q
314289
314290
V/Ph/Hz
314291
380/3/50
500/500/375
1.000/1.000/750
External static pressure (H/M/L)
Pa
80/68/45
100/85/58
170
Power input
W
170
360
1.340
Enthalpy exchange efficiency/
Cooling (H/M/L)
%
50/50/55
50/50/55
50
Enthalpy exchange efficiency/
Heating (H/M/L)
%
60/60/65
60/60/65
60
Temperature exchange efficiency (H/M/L)
%
65/65/70
65/65/70
65
dB(A)
35/34/28
40/39/33
53
1.020x1.036x270
1.276x1.269x388
1.650x1.470x540
35
69
165
⌀194
⌀242
346x326
Air flow rate (H/M/L)
Sound pressure level (H/M/L)
Dimensions (LxWxH)
Unit weight
m3/h
220-240/1/50
HRV 2000 R
mm
kg
Duct connection dimensions
Ambient condition
mm
°C
2.000
-7…+43/ max 80% RH
Fan performance
Air flow (m3/h)
SYSVRF HRV 500 Q
External static pressure (Pa)
Air flow (m3/h)
SYSVRF HRV 1000 Q
External static pressure (Pa)
Air flow (m3/h)
SYSVRF HRV 2000 Q
External static pressure (Pa)
Nominal conditions
Exhaust air
Fresh air
Cooling mode
27°C DB, 19,5°C WB
35°C DB, 28°C WB
Heating mode
21°C DB, 13°C WB
5°C DB, 2°C WB
The sound pressure value may vary depending on ambient conditions.
81
82
| VRF connection to AHU
Connection to DX coil
SYSCONTROL AHU
Features
The SYSCONTROL AHU 5HP, 10HP and 20HP can be used
to connect the SYSVRF outdoor units to an external DX
coil with capacity from 9 kW to 56 kW.
Nominal capacity in cooling 14kW (5HP), 28kW (10HP)
and 56kW (20HP).
Modulating cooling/heating capacity thanks to the
built-in Electronic Expansion Valve (EXV) controlled
by the superheat degree of the DX coil.
The SYSCONTROL AHU kit includes four temperature
sensors, one for the air intake of the AHU and three for
a precise monitoring of the DX evaporator coil.
For indoor installation in horizontal or vertical position.
Failure alarm codes on the PCB for quick service checking.
Environment friendly R410A refrigerant.
Connection to Systemair network monitoring system.
Wired
controller
SYSCONTROL
WC 29
(standard)
Wired controllor SYSCONTROL WC 29 as standard
equipment.
Connection diagram
max 8 m
SYSVRF indoor units
SYSCONTROL
AHU
max
175 m
SYSVRF
outdoor unit
FRICO Air Curtain
max 8 m
SYSCONTROL AHU
SYSTEMAIR Air Handling Unit
Technical features
Model AHU box
Art. no.
Power supply
DX coil capacity
Air volume
SYSCONTROL AHU 10HP
SYSCONTROL AHU 20HP
314188
314189
314190
V/Ph/Hz
kW
m3/h
Dimensions (LxWxH)
mm
Packing (LxWxH)
mm
Piping diameters in/out
mm
IP-class
Max current (1Ph motor)
SYSCONTROL AHU 5HP
A
220-240/1/50, 208-230/1/60
9-20
20-36
36-56
1.400~2.700
3.000~4.500
5.400~7.500
375x350x150
490x240x420
8/8
12,7/12,7
15,9/15,9
IP X0
IP X0
IP X0
5
30
30
VRF connection to AHU |
SYSVRF selection
and designing software
Selection and designing software for all SYSVRF systems, 2-pipe, 3-pipe and Mini-VRF.
Main tasks:
Calculation of the heat loads and selection of the
necessary cooling /heating capacity, type and location
of outdoor and indoor units.
Calculation of the refrigerant piping diameters and
the required additional amount of refrigerant.
Selection of an optimal set of piping joints.
Building Management System.
Correction of the performance of indoor units.
Automatic check of the circuit for compliance
requirements and limits on the maximum length of
refrigerant pipelines and indoor-outdoor elevations.
Conclusion of project documentation - specification
(Excel), a detailed specification with the drawings
(Word), and print out of all documents.
83
84
| VRF control systems
SYSCONTROL systems
Remote control for indoor units
Wireless infrared remote control SYSCONTROL RM 02
Main functions: on/off, cool/heat/auto/dry/fan mode of the air conditioner,
temperature setting , fan speed selection (high/medium/low/auto), 24h on/off
timer, TURBO mode, ECO mode, air flow/swing adjustment, display backlight button,
FOLLOW ME functions, keyboard locking function, 26 °C button.
Standard equipment for SYSVRF WALL, CASSETTE, CEILING. For 2-pipe and 3-pipe
SYSVRF. (Art. no. 314138).
Wired controller SYSCONTROL WC 90
Main functions: on/off, cool/heat/auto/dry/fan mode of the air conditioner,
temperature setting, fan speed selection (high/medium,low/auto), real 24h on/off
timer, swing button.
Standard equipment for SYSVRF DUCT, DUCT HP. Designed for 2-pipe SYSVRF HP with
automatic cooling/heating changeover. It can be used for 3-pipe SYSVRF HR with
manual cooling/heating changeover. (Art. no. 314139).
Wired controller SYSCONTROL WC 120
Main functions: on/off, cool/heat/auto/dry/fan mode of the air conditioner,
temperature setting , fan speed selection (high/medium/low/auto), 24h on/off timer,
air flow/swing adjustment, air filter function, keyboard locking button.
Optional equipment for all series of SYSVRF indoor units. Specifically designed for
3-pipe SYSVRF HR systems with automatic cooling/heating changeover and adjustable
dead band. It can be used in 2-pipe SYSVRF HP systems. (Art. no. 314182).
Centralized controllers
Centralized controller SYSCONTROL CWC 03 HP/HR
Monitors and manages 64 indoor units. Main functions: on/off, setting modes
(including the lock mode), change temperature settings, fan speed selection, query
function and error code of indoor units LCD with backlight. Provides the ability to
connect to a PC via a converter RS485/RS232.
(Art. no. 314140) CWC 03 HP for 2-pipe SYSVRF HP.
(Art. no. 314183) CWC 03 HR for 3-pipe SYSVRF HR.
Centralized controller SYSCONTROL CWC 09
Monitors and manages 64 indoor units. Perform the same functions of the central
control SYSCONTROL CWC 03, with the possibility of drawing up management program
for the week. LCD with backlight it doesn't have the port for the connection to a PC.
(Art. no. 314141).
Centralized monitoring of outdoor units SYSCONTROL CWC 02
Monitors up to 32 outdoor units which may be included in the 8 different VRF air
conditioning systems. When using a powermeter tra performs the accounting function
of electricity consumed. Ability to connect to a PC via a converter RS485/RS232. (Art.
no. 314142).
VRF control systems |
Intelligent Network Management System
Systemair multi-zone system can be integrated into a comprehensive building management system (BMS) thanks to the
Bacnet, Modbus or LonWorks gateway via SYSCONTROL CWC 08/CWC 11/CWC 64, respectively.
With the implementation of these gateway it is possible to use different control schemes: individual, group, network.
To one gateway Bacnet SYSCONTROL CWC 08 (Art. no. 314145) can be connected to up to 4 remote central control
(SYSCONTROL CWC 02 /SYSCONTROL CWC 03). Each group can contain a maximum of 64 indoor units/32 outdoor units.
Bacnet
SYSCONTROL RM 02
SYSCONTROL WC 90/WC 120
Max 64
SYSCONTROL
CWC 03
Bacnet
BMS
Max 64
SYSCONTROL
CWC 08
SYSCONTROL
CWC 03
Max 64
SYSCONTROL
CWC 03
Power digital motor
Max 32
S
SCO RO
SYSCONTROL
CWC 02
The central management console (SYSCONTROL CWC 03) can be connected to one gateway Modbus SYSCONTROL CWC 11
(Art. no. 314143). Each group can contain a maximum of 64 indoor units.
Modbus
Modbus
BMS
SYSCONTROL RM 02
SYSCONTROL WC 90/WC 120
Max 64
SYSCONTROL CWC 11
SYSCONTROL
CWC 03
Up to 64 indoor units can be directly connected to one gateway Lonworks SYSCONTROL CWC 64 (Art. no. 314144).
LonWorks
Lonwork
BMS
SYSCONTROL RM 02
SYSCONTROL CWC 64
SYSCONTROL WC 90/WC 120
Max 64
85
86
| VRF piping joint
Piping joints for 2-pipe refrigerant system
SYSVRF JOINT
Outdoor unit
Model
Art. no.
Packing LxWxH (mm)
Gross weight (kg)
SYSVRF JOINT OUT 02 HP
314146
255x150x185
1,5
Connect two outdoor units of SYSVRF AIR EVO HP R series
Use
SYSVRF JOINT OUT 03 HP
314147
345x160x285
3,4
Connect three outdoor units of SYSVRF AIR EVO HP R series
SYSVRF JOINT OUT 04 HP
314148
475x165x300
4,8
Connect four outdoor units of SYSVRF AIR EVO HP R series
Model
Art. no.
Packing LxWxH (mm)
Gross weight (kg)
SYSVRF JOINT IN 01 2P
314149
290x105x100
0,4
Capacity of connected indoor units < 23 kW
SYSVRF JOINT IN 02 2P
314150
290x105x100
0,6
Capacity of connected indoor units 23-33 kW
SYSVRF JOINT IN 03 2P
314151
310x130x125
0,9
Capacity of connected indoor units 33-92 kW
SYSVRF JOINT IN 04 2P
314152
350x180x170
1,5
Capacity of connected indoor units 92-135 kW
SYSVRF JOINT IN 05 2P
314153
365x195x215
1,9
Capacity of connected indoor units > 135 kW
SYSVRF JOINT IN 06 2P
314154
390x230x255
3,1
Capacity of connected indoor units 185 kW and long piping
Indoor unit
Use
Piping joints for 3-pipe refrigerant system
SYSVRF JOINT
Outdoor unit
Model
Art. no.
Packing LxWxH (mm)
Gross weight (kg)
SYSVRF JOINT OUT 02 HR
314155
272×167×232
2,2
Connect two outdoor units of SYSVRF AIR EVO HR R series
Use
SYSVRF JOINT OUT 03 HR
314156
472×157×312
5,0
Connect three outdoor units of SYSVRF AIR EVO HR R series
SYSVRF JOINT OUT 04 HR
314184
745×160×335
7,5
Connect four outdoor units of SYSVRF AIR EVO HR R series
Art. no.
Packing LxWxH (mm)
Gross weight (kg)
Indoor unit
Model
Use
SYSVRF JOINT IN 01 3P
314157
257×127×107
0,8
Capacity of connected indoor units < 16,6kW
SYSVRF JOINT IN 02 3P
314158
287×137×107
0,9
Capacity of connected indoor units 16,6-33kW
SYSVRF JOINT IN 03 3P
314159
297×167×177
1,4
Capacity of connected indoor units 33-66kW
SYSVRF JOINT IN 04 3P
314160
372×197×187
2,3
Capacity of connected indoor units 66-92kW
SYSVRF JOINT IN 05 3P
314185
432×222×227
3,3
Capacity of connected indoor units > 92kW
www.systemair.com
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement