Nortek Door-Gard 212iLM is a versatile keypad that offers enhanced security for your premises. With a 120-user capacity, it allows you to grant access to authorized individuals using unique codes. The programmable relay time (0-99 seconds) provides flexibility for various applications. The keypad features a request-to-exit (REX) input for convenient egress, and its vandal-resistant case ensures durability in demanding environments. The illuminated hardened keys are designed to withstand over a million cycles, making it ideal for high-traffic areas.
advertisement
PRINTER’S INSTRUCTIONS:
INSTR/PROG,212ILM-AL/212ILM-BZ - P/N: 6-051344 X2 - INK: BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: FLAT 17.000” X 11.000” FOLDED 8.500” X 11.000” - TOLERANCE: ± .125” - SCALE: 1-1
212iLM Keypad Installation & Programming
Specifi cations
Case Dimensions:
6-1/2” L x 1-3/4” W x 1-1/8” D
Electrical:
Voltage: 12-24 VAC/DC
Current:
53mA@12VDC
72 mA @ 24 VDC
95 mA@12 VAC
108 mA @ 24 VAC
Relay Contacts:
Main Relay (controller): 2 Amps
Bell Relay:
Form A; 1 Amp @ 30 VAC/DC
Environmental:
-20º F to 130° F
For Indoor and Outdoor Use
Description:
The Door ♦ Gard Series 212iLM keypad combines elegant looks with a mullion mount design in a rugged, vandal resistant case, which you can use for almost any application. The 212iLM has hardened backlit keys designed to perform in medium to high traffi c areas and in rough duty environments. The electronics are also conformal coated, which makes the keypad suitable for indoor or outdoor applications.
Basic Operation:
To gain access through the door enter your code
(1-6 digits) followed by the ✱ key on the keypad.
Packing List:
(1) 212iLM Keypad
(1) Eight-Conductor Wire Harness
(1) Mullion Hardware Pack
(1) 5/64” Allen Wrench
(1) Anti-Oxidant Grease Pack
(1) Installation/Programming Manual
212iLM Keypad
Installation & Programming Instructions
Note: This product is designed to be installed and serviced by security and lock industry professionals.
Features
● 120 User Capacity
● Programmable Relay Time (0 to 99 seconds)
● Request to Exit (REX) Input
● Vandal Resistant Case
● Sealed for Indoor or Outdoor Applications
● LED’s for Relay Status Indication
● Bell Output
● Surface Mount
● Illuminated Hardened Keys
● Rated for Greater than One Million Key Cycles
Applications
● Low to Medium/Heavy Traffi c Areas
● Rough Service Environments
● Mullion Frame Mounting
● Dimly Lit Areas
Wire Harness Confi guration:
6
7
4
5
8
2
3
Pin
1
Wire Color
Red
Black
White/Black
White/Yellow
Blue
Brown
White
White
Signal Name
Power (+)
Power (-)
REX
Main Relay NC
Main Relay Common
Main Relay NO
Bell Relay Contact (A)
Bell Relay Contact (B)
6-051344 X2 1
212iLM Keypad Installation & Programming
Keypad Installation Procedure:
Step 1: Drill through the back plate using a 11/64” bit. Use the template on the back page to accurately mark the mounting holes before drilling. Then drill the mounting holes with a 9/64” drill bit. Also drill the hole for the wires. This may vary depending on the number of conductors required. Refer to mounting height below.
Step 2: Wire the keypad using the diagrams in the following sections.
Step 3: Mount the 2121iLM keypad onto the mounting surface using the provided screws. Do no over-tighten the screws, which may result in damage.
Keypad Mounting Height
Mounting height can vary depending on requirements. An appropriate range is typically between 48 and 52 inches on center off the fl oor.
2 6-051344 X2
212iLM Keypad Installation & Programming
Wiring an Electromagnetic Lock (Maglock)
1. Connect the red (V+) and black (V-) wires to your power supply.
2. Connect the blue wire (relay common) to positive on your power supply.
3. Connect the white/yellow wire (relay normally closed) to the positive connection on your maglock.
4. Connect negative connection on your maglock to the negative on the power supply.
A fi ltered and regulated
DC power supply is recommended.
Basic Access Control Using an Electric Door Strike
1. Connect the red (V+) and black (V-) wires to your power supply.
2. Connect the blue wire (relay common) to positive on your power supply.
3. Connect the brown wire (relay normally open) to the positive connection on your door strike.
4. Connect negative connection on your door strike to the negative on the power supply.
6-051344 X2
A fi ltered and regulated
DC power supply is recommended.
3
212iLM Keypad Installation & Programming
Shunting a Normally Closed Zone
1. Connect the red (V+) and black (V-) wires to your power supply.
2. Connect the blue wire (relay common) to the common connection on the alarm contacts.
3. Connect the brown wire (relay normally open) to the normally open connection on the alarm contacts.
A fi ltered and regulated
DC power supply is recommended.
Wiring a Request to Exit Device (REX)
The 212iLM is equipped with a REX input. The normally open REX input triggers the main relay for the amount of time you programmed for the master code. If the master code is set to toggle, the REX only triggers the relay for 5 seconds. There is no programming required for the REX to operate.
1. Connect the red (V+) and black (V-) wires to your power supply.
2. Connect the common connection on the REX device to the negative on your power supply.
3. Connect the white/black wire to the normally open connection on the REX device.
4
A fi ltered and regulated
DC power supply is recommended.
6-051344 X2
212iLM Keypad Installation & Programming
Wiring the Bell Output to a Speaker:
The 212iLM keypad has a built in bell button, which triggers a relay output when pressed. This relay is normally open and the contact closes when triggered. You can use this relay output to trigger devices that require a momentary closure, such as a doorbell. The relay output provides a dry contact, but you can run up to 30 volts AC/DC through it for devices that require power to operate. The diagram below shows these connections.
6-051344 X2 5
212iLM Keypad Installation & Programming
Programming the 212iLM Keypad
To program the 212iLM you fi rst must enter program mode.
To enter program mode enter the following on the keypad: 99 # master code ✱ (default master code is 1234).
Keypad Default Settings
Option
Master Code
Default Setting
1234
Audio Keypress Feedback Enabled
Auto-Entry Disabled
Keypad Illumination Enabled
Option
Main Relay Time
Default Setting
5 Seconds
Visual Keypress Feedback Enabled
Door Bell Select Continuous
Keypad Dimming Enabled
Programming Options Chart
Command/Action
Change Master Code
Keys to Enter/Details
1 # new code ✱ new code ✱
Change Main Relay Time
Add/Change User
Add Toggle User relay time # 1 # master code ✱ master code ✱ user location # new code ✱ new code ✱
Note: Users programmed with this command use master code relay time.
00 # user location # new code ✱ new code ✱
Add User with Specifi c Relay Time relay time # user location # new code ✱ new code ✱
Command 30
Set/Clear Keypad Options
(options below, defaults in bold)
Option
0 – Audio Keypress Feedback
1 – Visual Keypress Feedback
2 – Auto-Entry
3 – Keypad Illumination
4 – Keypad Dimming
5 – Door Bell Select
Command 32
Set Bell Output Time
Command 46
Reset Keypad to Default Settings
Exit Program Mode
30 # option # set/clear #
Clear
0 = Disabled
0 = Disabled
0 = Disabled
0 = Disabled
0 = Disabled (always bright)
0 = Disabled
32 # 0 # time # ✱ ✱
32 # 0 # 0 # ✱ ✱
46 # 00000 # 00000 #
Press the ✱ Key
✱ ✱
✱ ✱
Set
1 = Enabled
1 = Enabled
1 = Enabled
1 = Enabled
1 = Enabled
1 = Enabled
Set timed output (1 – 99 seconds)
Set to continuous
Notes:
1. The 212iLM can store 120 user codes, including the master code. Codes can be from 1 to 6 digits long.
2. When auto-entry is enabled, users with codes the same length as the master code do not have to press the ✱ key after entering their code to enter the door.
3. When keypad dimming is disabled the backlighting remains at full intensity (does not dim).
4. When the door bell output is set to continuous the relay is energized as long the door button is pressed. When you release the button the relay de-energizes.
6 6-051344 X2
212iLM Keypad Installation & Programming
Programming Examples
Changing the Master Code
The following example show how to change the master code to 4875 from the default of 1234.
1. Enter Program Mode
2. Program New Master Code
3. Exit Program Mode
99 # 1234 ✱
1 # 4875 ✱ 4875 ✱
✱
Changing the Main Relay Time
The following example shows how to change the main relay time. The master code is 4875.
1. Enter Program Mode
2. Change the Main Relay Time
3. Exit Program Mode
99 # 4875
✱
✱
10 # 1 # 4875 ✱ 4875 ✱
Adding User Codes
The following example shows how to program user 2 with a code of 1749 and user 3 with 9328. The master code is 4875.
1. Enter Program Mode
2. Program User # 2
3. Program User # 3
4. Exit Program Mode
99 # 4875
2 # 1749
3 # 9328
✱
✱
✱ code ✱
✱ code ✱
Programming a Toggle User
The following example shows how to program user 4 as a toggle user with a code of 98773. The master code is 4875.
1. Enter Program Mode
2. Change the Main Relay Time
3. Exit Program Mode
99 # 4875
✱
✱
00 # 4 # 98773 ✱ 98773 ✱
LED Indications
LED State
Red Solid
Green Solid
Yellow Solid
Yellow Flashing Slowly
Yellow Momentary Flash
Description
Door Locked
Door Unlocked
Programming Error
Program Mode
Visual Keypress Feedback
6-051344 X2 7
212iLM Keypad Installation & Programming
Troubleshooting
Issue
LED’s cycling slowly from right to left.
LED’s cycling rapidly from left to right and the keypad has lost all operation.
Can’t access programming mode using the master code.
No LED’s are lit on the keypad.
Explanation
The 212iLM Mullion is designed to monitor for low voltage. Once low voltage is detected, the keypad turns off the backlighting to ensure operation of the keypad until the problem can be attended to.
Solution
Verify the power supply output voltage. If it is below the voltage threshold of 7.5 Volts AC or 9 Volts
DC, you must increase the voltage to between 12-24 Volts.
The 212iLM Mullion is designed to monitor for over voltage. This is a very “severe” condition and signifi cantly affects the keypad’s operation. Once the over voltage is detected, the keypad shuts down all operation and does not operate until the voltage is lowered.
The code you are entering is likely not the master code.
Verify the power supply output voltage. If it is over the voltage threshold of 35 Volts, you must lower the voltage below 29 Volts.
Perform the program mode loopback in the following section to enter program mode and reprogram the master code.
Power is not reaching the keypad.
First verify there is voltage at the keypad. If not, verify there is voltage at the power supply. If there is voltage, verify continuity on the wires out to the keypad.
Otherwise contact the power supply manufacturer or Nortek Security &
Control if there is a problem with the keypad. You also may try power the keypad with a 12V battery to verify operation.
DEALERS/INSTALLERS ONLY! End users must contact the dealer/installer for support. If the keypad still does not work after troubleshooting, please call the Technical Services department at 1-800-421-1587.
Testing the Keypad
After installing the keypad, it is recommended that you perform the keypad self-test once a year, to ensure that the keypad is working properly.
● To perform the self-test, with the unit powered up, press the following keys on the keypad: 7890 # 123456 ✱
● If all 12 key presses are accepted, the keypad enters self-test mode.
● The LEDs alternate three times followed by the sounder beeping three times.
8 6-051344 X2
212iLM Keypad Installation & Programming
Program Mode Loopback
If you’ve forgotten the local program code use the following loopback connection to enter program mode. Power down the unit, short the wires in the confi guration illustrated, then power the unit back up. The yellow LED should be fl ashing.
Now change your local program code or reset the unit. Power the keypad down and reconnected the wire harness in the original confi guration.
6-051344 X2 9
212iLM Keypad Installation & Programming
Limited Warranty
This Nortek Security & Control product is warranted against defects in material and workmanship for twenty four (24) months. This warranty extends only to wholesale customers who buy direct from Nortek Security & Control or through
Nortek Security & Control’s normal distribution channels. Nortek Security & Control does not warrant this product to consumers. Consumers should inquire from their selling dealer as to the nature of the dealer’s warranty, if any. There are no obligations or liabilities on the part of Nortek Security & Control LLC for consequential damages arising out of or in connection with use or performance of this product or other indirect damages with respect to loss of
property, revenue, or profi t, or cost of removal, installation, or reinstallation. All implied warranties, including implied warranties for merchantability and implied warranties for fi tness, are valid only until the warranty expires. This Nortek
Security & Control LLC Warranty is in lieu of all other warranties express or implied.
All products returned for warranty service require a Return Authorization Number (RA#). Contact Returns at
1-855-546-3351 for an RA# and other important details.
10 6-051344 X2
212iLM Keypad Installation & Programming
PAGE LEFT BLANK INTENTIONALLY
6-051344 X2 11
212iLM Keypad Installation & Programming
212ilM Mounting Template
Copyright © 2015 Nortek Security & Control LLC
12 6-051344 X2