TDK-Lambda ELV12 SPECIFICATIONS

TDK-Lambda ELV12 SPECIFICATIONS
TDK-Lambda
ELV12
SPECIFICATIONS
V002-01-01E
MODEL
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
ITEMS
Nominal Output Voltage
V
Minimum Output Current
A
Maximum Output Current
A
Maximum Output Power
W
Efficiency (Typ)
(*1) 100VAC %
200VAC %
Input Voltage Range
(*2) Input Current (Typ.)
(*1) A
Inrush Current (Typ.)
(*3) Output Voltage Accuracy
(*4,5) Total Regulation
(*5) Output Ripple & Noise
(*4,5) mV
Over Current Protection
(*6) Over Voltage Protection
(*7) Turn On Time (Typ.)
ms
Operating Temperature
(*8) IP Class
(*9) Operating Humidity
Storage Temperature
Storage Humidity
Cooling
Withstand Voltage
Isolation Resistance
Leakage Current
(*10) -
24
Vibration
-
25
26
27
Shock (In Package)
EMI (Conducted & Radiated Emission)
Immunity
-
28
Safety Standard
-
29
30
Weight (Typ.)
Size (L x W x H)
g
mm
1
2
3
4
5
ELV12-12-1R0
ELV12-24-R50
12
0.1
1
12
81
82
24
0.05
0.5
12
83
84
90 - 265 VAC (47Hz - 63Hz)
0.28A at 100VAC, 0.18A at 200VAC
25A at 100VAC, 50A at 200VAC, Ta = 25°C, Cold Start
±3%
±3%
100
150
>105% Rated Output Power
>110%
30
-10 - +60°C
IP66
15 - 90%RH (No Condensing)
-30 - +85°C
15 - 90%RH (No Condensing)
Convection Cooling
Input - FG : 2kVAC, Input - Output : 3kVAC, for 1 min (10mA Max.)
>100M at 25°C and 70%RH. Output - FG : 500 VDC
Less than 0.5mA. 0.15mA(Typ.) at 100VAC / 0.3mA(Typ.) at 200VAC
At no operating, 10 - 55Hz (Sweep for 1min)
19.6m/s2 Constant, X,Y,Z 1hour each.
Less than 196.1m/s²
Designed to meet EN55015 ; EN55022-B ; VCCI-B ; CISPR 22-B ; FCC-B
Designed to meet IEC61000-6-2 IEC61000-4-2, -3, -4, -5, -6, -8, -11
PSE mark (Den-an Appendix 8)
Designed to meet UL8750 (Class2), EN61347-1, EN-61347-2-13, EN62384
230
L:104(122 including mounting bracket) W:36.5 H:27.2
*Read instruction manual carefully, before using the power supply unit.
=NOTES=
*1 : At maximum output power , Ta = 25°C.
Figure A measurement set up
*2 : For cases where conformance to safety
End of output wire
spec (Den-an) is required, to be described
150mm
as 100-240VAC, 50/60Hz on name plate.
+V
A
*3 : Not applicable for the in-rush current to noise filter for less than 0.2ms.
PSU
*4 : At Vin=100/200VAC & maximum output power, Ta = 25°C.
R1
C2
C1
*5 : Refer to Fig. A for measurement determination.
-V
*6 : Current limiting with automatic recovery or shutdown output (at high temperature).
Please refer instruction manual.
Measurement point for output voltage,
Avoid over load and short circuit condition.
*7 : OVP circuit will shutdown output,
regulation and ripple & noise voltage.
manual reset ( Re-power on).
Measure with JEITA probe.
*8 : For cases where conformance to safety specs,
Bandwidth of oscilloscope : 20MHz
operating case or ambient temperature will be specified.
R1 = Electronic load
Please refer instruction manual.
C1 = Elect. Cap. 100uF
*9 : Conditions : Please refer instruction manual.
C2 = Film Cap. 0.1uF
*10 : Measured by measuring method of Den-an (at 60Hz), Ta=25°C.
V
TDK-Lambda
ELV12
OUTPUT DERATING
V002-01-02
*COOLING : CONVECTION COOLONG
LOAD (%)
Ta (°C)
-10 - +60
100
OUTPUT DERATING CURVE
120
100
LOAD (%)
80
60
40
20
0
-10
0
10
20
30
40
Ta ( C)
50
60
70
80