THCU Series Data Sheet

THCU Series Data Sheet
Timing Mode: DELAY ON MAKE
Category: SOLID STATE TIMER
Series: THCU-E
CUBE SOLID STATE, UNIVERSAL AC/DC WIDE VOLTAGE, DIPSWITCH
THCU Timer
THCU is a universal AC/DC voltage solid state
timer in a compact 2" x 2" configuration. This unit
features wide operating voltages: 19 to 265 VAC
and 10 to 120 VDC.
THCU-E offers three time ranges: 0.1 second to
102.3 seconds in 0.1-second increments,1 second
to 1023 seconds in 1-second increments, or 10 to
10230 seconds in 10-second increments. Tenposition binary dipswitch is easy to program.
Advanced digital circuitry provides this timing
module with unsurpassed accuracy and reliability.
Available with factory-fixed time as THCU-C.
Timing Mode
ON
INPUT
VOLTAGE
Application of input voltage to the timer starts the time delay.
At the end of the delay period, the load is energized.
To reset, remove the input voltage to the timer.
LOAD
OFF
ON
DELAY
OFF
FEATURES
■ Wide and universal operating voltage in a single unit:
operates from 19-265 VAC and 10-120 VDC
■ Operates at 50/60Hz
■ DC polarity independent
■ Precise timing accuracy in three ranges:
0.10 to 102.3 seconds in 0.1-second increments
1 to 1023 seconds in 1-second increments
10 to 10230 seconds in 10-second increments
■ Easy to program with 10-position binary dipswitch
■ Digital timing accuracy
■ Time setting accuracy of ±5% of set point
■ Repeatability of ± 0.1%
36
■ Extremely low off-state leakage current
■ Fixed time periods available
■ Eliminates contactor “hum”
■ Compact, easy to hook up, in-line
installation
■ Vertical mounting option available
with MB-1 Bracket
■ Totally encapsulated for protection
from harsh environments
■ 100% Operational testing before shipping
■
■ RoHS compliance available
DIMENSIONS AND TIME RANGE SELECTION
1
LOAD
Supply Voltage
2"
512
256
64
128
32
COMBINE SWITCHES FOR
TIME DELAY IN SECONDS
19-265 VAC / 10-120 VDC
3
NEUT. AC
GND. DC
8
4
2
Hole = .25"
HOT AC
+ DC
512
256
64
128
32
ON
16
.75"
8
1.14"
4
To set a time period simply add up the
selected switches in the “on” position
for the total delay in seconds.
2
3
2"
1
1
1
Terminals = .25"
16
ON
1+2+4+8+256 = 271 seconds of delay
Surface Mount with #8 or #10 Screw
SPECIFICATIONS
Repeat Accuracy: ±0.1% under fixed conditions
Time Range: 0.1–102.3 seconds in 0.1-sec. increments
1–1023 seconds in 1-sec. increments
10–10230 seconds in 10-sec. increments
Reset Time: 25 milliseconds after timing cycle
200 milliseconds during timing cycle
Timing Tolerence: ±10% max ±5% typical
Operating Voltage:
19-265 VAC/10-120 VDC
50/60Hz
Mode of Operation: Delay on Make
Storage Temperature: -40°C to +85°C
Operating Temperature: -25°C to +65°C
Transient Protection: 18 joules varister
Voltage Drop in “On” State:
4 volts max / 3 volts nominal @ 1 amp peak
Output Leakage Current in “Off” State:
6.4 mA @ 265 VAC
3.3 mA @ 120 VAC
1.6 mA @ 48 VAC
1.0 mA @ 24 VAC
Switching Current:
1 Amp steady state max.
10 mA min.
10 Amps inrush
OPTIONS SELECTION
Mode of Operation
Series
Input Voltage
Time Ranges
Time Adjustment Method
VARIABLE TIME PERIODS
Delay On Make
THC
Standard Size
(2" x 2")
EXAMPLE
U
19-265 VAC
10-120 VDC
102S3 0.1 to 102.3 sec. (in 0.1 sec. increments)
1023 1 to 1023 sec. (in 1 sec. increments)
10230 10 to 10230 sec. (in 10 sec. increments)
E Variable, Dipswitch
C Fixed Time
THCU060SC = 60 seconds fixed
THC U 1023 E Time range 1 to 1023 seconds in 1-second increments
Specifications subject to change without notice.
2747 Route 20 East, Cazenovia, NY 13035
315-655-8476 ■ www.airotronics.com