Maintaining the Ethernet Link to the BMC During Server Power Actions

Maintaining the Ethernet Link to the BMC During Server Power Actions
Maintaining the Ethernet Link to the
BMC During Server Power Actions
Using the Advanced Manageability Feature of Intel Ethernet Controllers
Intel® LAN Access Division
Revision 1.0
October 2012
Legal
INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS
OR IMPLIED, BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS
DOCUMENT. EXCEPT AS PROVIDED IN INTEL'S TERMS AND CONDITIONS OF SALE FOR SUCH PRODUCTS, INTEL
ASSUMES NO LIABILITY WHATSOEVER AND INTEL DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY, RELATING
TO SALE AND/OR USE OF INTEL PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A
PARTICULAR PURPOSE, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER
INTELLECTUAL PROPERTY RIGHT.
A "Mission Critical Application" is any application in which failure of the Intel Product could result, directly or
indirectly, in personal injury or death. SHOULD YOU PURCHASE OR USE INTEL'S PRODUCTS FOR ANY SUCH
MISSION CRITICAL APPLICATION, YOU SHALL INDEMNIFY AND HOLD INTEL AND ITS SUBSIDIARIES,
SUBCONTRACTORS AND AFFILIATES, AND THE DIRECTORS, OFFICERS, AND EMPLOYEES OF EACH, HARMLESS
AGAINST ALL CLAIMS COSTS, DAMAGES, AND EXPENSES AND REASONABLE ATTORNEYS' FEES ARISING OUT OF,
DIRECTLY OR INDIRECTLY, ANY CLAIM OF PRODUCT LIABILITY, PERSONAL INJURY, OR DEATH ARISING IN ANY
WAY OUT OF SUCH MISSION CRITICAL APPLICATION, WHETHER OR NOT INTEL OR ITS SUBCONTRACTOR WAS
NEGLIGENT IN THE DESIGN, MANUFACTURE, OR WARNING OF THE INTEL PRODUCT OR ANY OF ITS PARTS.
Intel may make changes to specifications and product descriptions at any time, without notice. Designers must not
rely on the absence or characteristics of any features or instructions marked "reserved" or "undefined". Intel
reserves these for future definition and shall have no responsibility whatsoever for conflicts or incompatibilities
arising from future changes to them. The information here is subject to change without notice. Do not finalize a
design with this information.
The products described in this document may contain design defects or errors known as errata which may cause
the product to deviate from published specifications. Current characterized errata are available on request.
Contact your local Intel sales office or your distributor to obtain the latest specifications and before placing your
product order.
Copies of documents which have an order number and are referenced in this document, or other Intel literature,
may be obtained by calling 1-800-548-4725, or go to: http://www.intel.com.
Intel and Intel logo are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United
States and other countries.
*Other names and brands may be claimed as the property of others.
Copyright © 2008-2012. Intel Corporation. All Rights Reserved.
Revisions
Date
October 2012
Revision
1.0
Description
Initial Release
Intel Manageability Critical Session
2
Revision 1.0
Contents
1
BMC Ethernet Connectivity ............................................................. 4
1.1
1.2
1.3
1.4
The Physical Layer of the OSI Model ........................................................... 4
Importance of Link When Server is Powered Off ........................................... 4
Times When the Link Goes Down................................................................ 5
BMC Connectivity During Link Down/Up Times ............................................. 5
2
Sometimes a Quick Link Down/Up Causes Interruption in Connectivity
for Minutes ......................................................................................... 5
3
The Solution – the Critical Session Feature ....................................... 7
3.1
3.2
3.3
3.4
3.5
4
Related Technology – Low Power Link Up .................................................... 7
How to Use the Critical Session Feature....................................................... 7
Potential Side Effects of the Critical Session Feature...................................... 8
3.3.1
Excess Power Usage Link Speed Stays High .................................... 8
3.3.2
Reduced Link Speed in the Operating System ................................. 8
Suggested Use of the Critical Session Feature .............................................. 8
Lifetime of the Critical Session Feature ........................................................ 9
Not All Customer Designs are the Same ......................................... 10
4.1
4.2
4.3
Enable Critical Session Only Once .............................................................. 10
Always Link at 1 Gbps .............................................................................10
Session Began When Server was Powered Down and at Low Link Speed .........11
5
Summary................................................................................... 11
6
Additional Resources ................................................................... 11
1 BMC Ethernet Connectivity
In most modern servers a Baseboard Management Controller (BMC) is responsible for
monitoring things such as temperature, voltages and fans. The BMC can usually be
configured to send out alerts (in the form of emails and/or SNMP alerts) when something in
the system requires the attention of an administrator (such as the CPU starting to
overheat).
The BMC usually has network connectivity via the sideband interface on some kind of LAN
On Motherboard (LOM). The most common sideband interface is Network Controller
Sideband Interface (NC-SI) defined by the DMTF and available on many Intel as well as
other vendor’s Ethernet Controllers. The NC-SI interface provides a mechanism by which
the BMC can share Ethernet connectivity with the operating system.
The BMC can use this Ethernet connectivity to enable a remote management application to
establish a connection. Over this connection a management application can do such things
as view the temperature, voltage and fan sensors along with a great many other tasks. One
popular usage for this connection is Serial over LAN (SoL) by which one can reboot a server
and do tasks such as BIOS configuration. A more advanced feature is Keyboard, Mouse &
Video (KVM) redirection, which enables the BMC to provide a remote desktop type of
capability independent of the operating system.
1.1 The Physical Layer of the OSI Model
The Open System Interconnect (OSI) model has 7 layers to it. Layer 1 is the physical layer;
this is usually what Intel refers to as a PHY on an Ethernet device. The PHY is the port that
the Ethernet cable plugs into. On many PHY’s you’ll find LED’s that indicate that there is
power, as well as a link state. There are usually different colors for different link speeds
such as 10 Mbps, 100 Mbps and 1 Gbps; if the link LED is off, it indicates no link.
1.2 Importance of Link When Server is
Powered Off
As the BMC is used for remotely managing a server, which includes powering it on and off
as well as rebooting it when the operating system hangs, it is important that the BMC have
network connectivity even when the computer is operating only on standby power (basically
plugged into the wall, but powered down).
In order to achieve this, the LOM must also be designed to work on standby power. This is a
basic requirement for server manageability – the BMC and the LOM must be connected to
standby power in order to manage a server that is powered down.
Intel Manageability Critical Session
4
Revision 1.0
1.3 Times When the Link Goes Down
There is a time during normal operations of a server that the link can go down and then
back up. When a server is in a powered off state and is powered on, the PE_RST_N
(PERST#) signal is usually asserted, causing the Ethernet controller to reset and reinitialize. This action of resetting the Ethernet controller causes the link to momentarily be
lost (usually less than a second).
If the software device driver (or BMC via NC-SI) renegotiates the link speed, the link also
goes down momentarily.
1.4 BMC Connectivity During Link
Down/Up Times
There are times when the network link momentarily goes down and then back up. If this is
a short enough time period (a couple of seconds or so) this usually does not cause any
major issues even if a management console is connected to the BMC. This is because many
times the network traffic going to the BMC is UDP and the IPMI protocol has a retry
mechanism defined.
In many cases, even if the traffic is TCP/IP based (say for example for a KVM session), it
too will have a retry mechanism that would be tolerant of such a momentary loss of
connectivity.
2 Sometimes a Quick Link
Down/Up Causes Interruption in
Connectivity for Minutes
There is a case where even if the link goes down and then back up within a second, a
remote application is not able to communicate with the BMC over the network for up to
several minutes. This occurs when the Spanning Tree Protocol (STP) is used within the
switches between the management console and the BMC.
Figure 1 Interconnected Switches
With spanning tree, many switches are interconnected that among other things provides
redundancy. Spanning tree makes it so that a packet does not get repeated – meaning only
one switch passes the directed packet along.
When a switch detects a link down/link up condition on a port, it reactivates the STP, as it
doesn’t know which topology reconnected after the link was re-established and whether new
loops where created. It might take minutes until the link is moved by the STP to active state
again. During this time the BMC is not able to communicate with the remote management
console.
The end result is that if you are wanting to reboot your server to use SoL in order to go into
BIOS and configure something – you won’t be able to do so because by the time the STP reestablishes connectivity to the BMC, the BIOS setup option has likely long since passed and
the server running the operating system.
Intel Manageability Critical Session
6
Revision 1.0
3 The Solution – the Critical
Session Feature
Having recognized this issue many years ago, Intel Ethernet controllers have a feature Intel
calls a critical session by which the BMC can tell the Intel Ethernet controller to NOT reset
the device and to keep that PHY connection steady just as it is.
Using this feature, the BMC can configure the critical session via the sideband interface and
prevent the loss of link and the potential loss of connectivity.
3.1 Related Technology – Low Power Link
Up
Wake on LAN (WoL) is another technology that requires the Ethernet device and PHY to be
powered when the server is running on standby power. It enables you to power down your
server until needed and then have it power on after your Ethernet device receives a WoL
packet.
One usually powers down a server that is not needed and has it enabled for WoL in order to
save on power usage – no need to have the server fully powered until it is needed. So if
your Ethernet controller is a 1 Gbps device such as the Intel® Ethernet Controller I350,
many would consider it a waste of power for the Ethernet device to maintain a 1 Gbps link
to the switch. Note that a 10 Mbps or 100 Mbps connection works just as well for WoL, yet
requires a lot less power.
Intel Ethernet controllers have the Low Power Link Up (LPLU) feature that enables the link
to be renegotiated down to a lower speed when the server is running on standby power. So
what this means is, if you power off your server, the Intel Ethernet controller (if so
configured) attempts to negotiate the link speed down to the lowest possible link speed in
order to save power.
3.2 How to Use the Critical Session
Feature
This feature requires a two-step process. It must be first enabled in the NVM/EEPROM of
the Intel Ethernet controller (which is the default), and then the BMC must send a command
to the Intel Ethernet controller over the sideband interface.
This feature is supported over both the NC-SI interface using an Intel OEM NC-SI command
(Set Intel Management Control Command) and over the SMBus interface. Refer to product
specific documentation (http://www.intel.com/products/ethernet/resource.htm) for details.
3.3 Potential Side Effects of the Critical
Session Feature
Once this feature is enabled, the link state does not change (unless of course the link
partner, such as the switch changes), the software device driver cannot change the link
speed and if the link partner attempts to renegotiate the link speed, the only option
available is that of the current speed.
3.3.1 Excess Power Usage Link Speed Stays High
Let’s take an example where the server is fully powered and the operating system is up and
running and has negotiated the link of the Intel Ethernet port to 1 Gbps. For some reason
the BMC gets reset (perhaps a firmware update occurred). The BMC might, as part of its
configuration setup the Intel critical session feature. All is good right?
Well, maybe not, depends on your desired usage. If the server is then powered down, the
link speed remains at 1 Gbps – drawing more power. The Low Power Link Up (LPLU)
feature is overridden when the critical session feature is active – it does not renegotiate to a
lower link speed to save power.
This means that your server might now be drawing more power than you want in a powered
down state.
3.3.2 Reduced Link Speed in the Operating System
Let’s imagine that the Intel Ethernet controller you are using (say the upcoming Intel®
Ethernet Controller I210) has the Low Power Link Up (LPLU) enabled. The server at first
has no power to it and then it is plugged in. The BMC goes and gets itself all initialized,
while at the same time the Intel® Ethernet Controller I210, using the Low Power Link Up
(LPLU) feature, negotiates a nice power saving link speed of 10 Mbps. The BMC now
configures the critical session feature.
Sometime later the server is powered on (by pressing the power button, via the BMC or
even by WoL) and booted to the operating system. Since the critical session feature is
configured, when the software device driver in the operating system goes to initialize the
port on the Intel® Ethernet Controller I350, it recognizes that the critical session feature is
active and leaves the link as it is, at 10 Mbps.
So now you have your 1 Gbps Ethernet device only running at 10 Mbps, at 1% of potential
speed.
3.4 Suggested Use of the Critical Session
Feature
While the critical session feature available in the Intel Ethernet controllers prevents the link
from dropping during power ups, there are some potential side effects if not used with
caution and wisdom.
In most cases, this feature should be only activated when the BMC has an active session
with a remote management application. When there is no active session, the feature should
Intel Manageability Critical Session
8
Revision 1.0
be deactivated.
The following flow charts provide the basic algorithms.
Figure 2 Critical Session Usage Algorithms
Only the BMC knows when there is an active connection with a remote management
console, the Ethernet controller has no specific knowledge of when a session begins or ends.
For this reason, the BMC should specifically enable and disable this feature as needed.
3.5 Lifetime of the Critical Session
Feature
Intel recognized that some BMC’s might simply configure the critical session feature and
then forget to turn it off. As such, on many of the Intel Ethernet controllers that support
this manageability feature, it is disabled after a reset has occurred.
Technically speaking, when the Main Power OK (MAIN_POWER_OK) pin is negated, the
critical session feature is turned off and the BMC must re-enable (re-arm) it. In this way,
the BMC must explicitly re-arm the feature and the potential side effects does not occur.
The MAIN_POWER_OK pin does not exist on the cost-optimized Intel Ethernet controllers
such as the Intel® 82574 GbE Controller and the Intel® Ethernet Controller I210. For these
devices, the BMC must explicitly enable and disable the feature.
4 Not All Customer Designs are
the Same
Server manufactures design different servers for different environments. Some servers
using Intel 1 Gbps devices require that the link always be 1 Gbps and never negotiate down
to a lower link speed to save power.
Sometimes the BMC designers want to enable the critical session feature and have it stay
enabled until a complete loss of power.
The following are a series of recipe’ that should cover most of the desired usage models.
4.1 Enable Critical Session Only Once
In this situation, the BMC wants to enable the feature and never have to re-arm it. On the
Intel® 82574 GbE Controller and the Intel® Ethernet Controller I210, this is the default
behavior. On other devices this feature is un-armed after the negation of the
MAIN_POWER_OK pin.
In order to make it so that the BMC can arm the critical session feature and the forget about
it, the board designers must make sure that the MAIN_POWER_OK pin does not get
asserted. The recommended method to do this is to tie the MAIN_POWER_OK pin to the
AUX POWER pin.
The only activity the MAIN_POWER_OK pin does is to signal to the Intel Ethernet controller
that it should reset the critical session feature, as such by tying it to AUX POWER, the
feature is never reset unless AUX POWER is lost.
4.2 Always Link at 1 Gbps
There are a couple of ways to achieve this. First that if the BMC is using NC-SI to connect
to the Intel Ethernet controller, it can always use the NC-SI commands to set the link speed
as it sees fit.
The other way is to, in the NVM/EEPROM of the Intel Ethernet controller, configure it so that
Low Power Link Up (LPLU) links only at 1 Gbps. Talk to your Intel account representative on
how to obtain an NVM/EEPROM image configured in such a way.
Intel Manageability Critical Session
10
Revision 1.0
4.3 Session Began When Server was
Powered Down and at Low Link
Speed
If Low Power Link Up (LPLU) is configured to save power and has negotiated the link to a
low link speed and then the BMC session is established and the BMC, as suggested, enables
the critical session feature and at a later time, while the BMC session is still active, the
server is powered on and boots in the operating system, the link remains at the low link
speed as described in Section 3.3.2.
Since the software device driver only tries to autonomously negotiate the link speed when
the device is initialized, there are only a couple options available. After the BMC session has
ended, it could either reboot the server again, and when the software device driver in the
operating system is loaded it negotiates the link to the desired speed.
Another option is to have the BMC (if it is using NC-SI) renegotiate the link on behalf of the
operating system using the NC-SI Set Link command. The drawback of this solution is that
if for some reason the operating system were using the Ethernet port, it would lose
connectivity briefly if not using STP on the switches or up to minutes if it was.
5 Summary
The critical session feature is available in many Intel Ethernet server controllers. This
feature can keep the BMC from losing connectivity, in particular when STP is being used
within the switches upstream from the server.
To make the most out of the critical session feature, the BMC should be an active participant
in the usage of this feature, enabling it when there is an active remote management
connection to the BMC and disabling it when finished with the session.
6 Additional Resources
Intel Ethernet Controller documentation
http://www.intel.com/products/ethernet/resource.htm
Manageability – Intel® Sideband Technology