E-8000 Power Supply / Readout & Control

E-8000 Power Supply / Readout & Control
SERIES E-8000
Digital Readout / Control Systems
> Single and Dual Channel Modules
Bronkhorst High-Tech B.V., manufacturers of advanced mass flow
metering and control systems, offer digital Readout/Control Modules
for use with digital Mass Flow Meters/Controllers, Pressure Meters/
Controllers and other transmitters and transducers with RS232 communication. The E-8000 Series have one or two colour TFT displays per
module for indication of measured/totalised values and a push button
menu to easily enable the user to change the setpoint, reset the counter
value, select other fluids and many functions more.
> Features
> Multi Channel Configurations
uBright, wide angle, 1.8” display (TFT technology)
uUser friendly operation, menu driven with 4 push buttons
uIndication/operation/configuration of
Based on the modular technique of the E-8000 series, it is easy to
assemble multi channel configurations in ½ 19” and 19” housings,
either for rack mount or table top. The exact number of channels to
be served with one (½ 19”) or two (19”) power supplies, depends on
the type of instruments (meters/controllers) to be connected. For most
applications one power supply can serve at least four channels.
-
measured value (direct or %)
setpoint
totalised flow
fluid / tag number
control characteristics
fieldbus settings
alarm functions (min/max, response, counter)
fluid selection (up to 8 fluids/curves stored in MFM/MFC)
> Specifications
Mechanical:
u1- or 2-channel table top housing (1 module)
u1- or 2-channel cassette for panel mounting (1 module)
u½ 19” table top housing (max. 3 modules)
u½ 19” rack housing (max. 3 modules)
u19” table top housing (max. 6 modules)
u19” rack housing (max. 6 modules)
uAs an option, ½ 19” and 19” housings can be supply with front
handles or carrying handles
uAn overview of the dimensions can be found on the last page
> Configurations for CEM-system
Electrical:
For Controlled Evaporation Mixing (CEM) systems a single channel
module for temperature control can be integrated into a 1-channel
cassette and ½ 19” or 19” housings. This module is available with or
without display and with various fieldbus options.
u Mains voltage 100...240 Vac (50...60 Hz)
u Output signal/setpoint signal: Digital: FLOW-BUS (RS-485) or RS-232
uOption for CEM-modules only: PROFIBUS DP, PROFINET,
DeviceNet™, Modbus or EtherCAT® interface
u Subminiature D-connector socket for RS-232 instrument connection
u RJ45-connection for connection with FLOW-BUS communication
u Power Supply capacity +24 Vdc, 1.25 A (30 W)
> Model number identification
> Examples of typical configurations
I) Model key housing, mains supply and bus options
Blind power supply
E-8
By means of a blind power supply module one or two instruments can
be powered (total power consumption max. 30 W). The model key for
this typical example is E-8501-0-0A
N
N
N
A
-
Code
Code
Code
Code
-
N
A
....
Bus options
0
no external communication
A
RS232
R
FLOW-BUS
Z
specified
Mains and instrument power supply
0
n.a.
1
1) 2)
2
3)
3
1) 2)
4
3)
5
1) 2)
6
3)
110..120Vac / 24Vdc instrument/FLOW-BUS dual supply
7
4)
220..240Vac Mains supply
8
4)
110..120Vac Mains supply
9
special
100..240Vac / 24Vdc instrument/FLOW-BUS single supply
100..240Vac / 24Vdc instrument/FLOW-BUS dual supply
220..240Vac / 24Vdc instrument/FLOW-BUS single supply
220..240Vac / 24Vdc instrument/FLOW-BUS dual supply
110..120Vac / 24Vdc instrument/FLOW-BUS single supply
no handles
1
front handles
2
carrying handle
1)
2)
Housing
1
½ 19” tabletop housing
2
19” tabletop housing
3
½ 19” rack housing
4
19” rack housing
5
tabletop cassette
6
panelmount cassette
9
special
FLOW-BUS terminal
II) Model key power supply modules
E-8
N
Via RS232 one or two instruments can be hooked up per module. The
model key for this typical example is E-8501-0-2A
ingle supply in cassette or ½ 19”
S
housing, max. load: 30 Watt
Dual supply in 19” housing,
max. load: 2x30 Watt
3) Mains supply for CEM only
Handles
0
Instrument terminal
N
N
-
Code
Code
0
A
-
N
A
....
FLOW-BUS is a field bus, designed by Bronkhorst, based on RS485
technology, for digital communication between digital devices,
offering the possibility of host-control by PC or digital R/C-module
(E-8000 or BRIGHT). Below example shows two instruments with integrated FLOW-BUS interface in a bus configuration with an E-8000
module. The model key for this typical example is E-8501-R-20
Rear panel
0
FLOW-BUS Power Supply (only at 1st or 2nd Supply unit)
A
2x 9pSub Instrument Power Supply
Front panel
blind
III) Model key readout/control modules
E-8
N
N
N
-
A
-
Code
Code
N
A
....
Rear panel
0
none, FLOW-BUS terminal only
A
RS232 instrument readout
Below you will find a FLOW-BUS set-up with 6 Mass Flow Meters.
The model key for this example is E-8101-R-20-20-20
Front panel
0
blind
1
1 display
2
2 displays
Alternatively only one display can be used to readout these instruments sequentially; model key for this option is E-8101-R-10-00-00
> Model number identification
> Examples of typical configurations
IV) Model key CEM (Controlled Evaporation Mixing) modules
CEM-System, RS232 set-up
E-8
N
N
N
A
-
-
N
A
A
Code
Code
W
Code
Code
A
....
Analog actuator
U
W100/W200
V
W300
Z
specified
Code
Code
A
The following hook-up drawing illustrates a typical example of a
stand-alone Controlled Evaporation Mixing (CEM) system, consisting of a Mass Flow Meter for liquid (e.g. a precurser or water used
for humidification purposes), a Mass Flow Controller for carrier gas
and a mixing device with subsequent heater element. The E-8000
unit p
­ owers the three devices and communicates via RS232. Model
­number for this example is E-8103-0-1WATU-1A-1A
Analog sensor input/sensor
T
PT100 temperature
Z
specified
Ext. analog setpoint and output
0
none
A
0-5 Vdc
B
0-10 Vdc
F
0-20 mAdc sourcing
G
4-20 mAdc sourcing
Z
specified
Rear panel
CEM
Front panel
0
blind
1
1 display
Bus options
0
no external communication
A
module bus E-8000 RS232
D
module bus E-8000 DeviceNet™
M
module bus E-8000 Modbus
P
module bus E-8000 PROFIBUS DP
R
module bus E-8000 FLOW-BUS
T
module bus E-8000 EtherCAT®
V
module bus E-8000 PROFINET
Z
specified
CEM-System, fieldbus set-up
When the Controlled Evaporation Mixing (CEM) system should be part
of a fieldbus system, the set-up may be arranged as in below drawing,
where the devices are hook-up to a PROFIBUS network. Model number for the PS/Readout in this illustration is E-8507-P-1WATU
Fieldbus connections for CEM temperature control
14TE Cassette table top housing
19” housing
14TE Cassette rack mount housing
½ 19” housing
Nijverheidsstraat 1a, NL-7261 AK Ruurlo The Netherlands
T +31(0)573 45 88 00 F +31(0)573 45 88 08 I www.bronkhorst.com E [email protected]
9.60.043C
©BHT-T163108
> Dimensions