Protege | PRT-CTRL-SE | Protégé® SE Integrated System Controller

Protégé® SE Integrated
System Controller
The Protégé® SE Integrated System Controller is the central processing unit
responsible for the control of security, access control and automation in the
Protégé® integrated system, an advanced technology security product providing
seamless and powerful integration of access, security and building automation.
The Protégé® SE Integrated System Controller is the central
processing unit responsible for the control of security, access control
and automation in the Protégé® integrated system, an advanced
technology security product providing seamless and powerful
integration of access, security and building automation.
• Internal industry standard 10/100 Ethernet.
• Communicate with Ethernet modules that are interconnected
using a LAN or corporate network.
• In-built offsite line communications dialer (ContactID, SIA).
• 32 Bit advanced RISC processor with 2MB RAM and 4MB flash.
• 16x high security monitored zone inputs.
• 2x high current outputs.
• Firmware upgradable using standard IT technology.
• Enhanced technology power supply with battery charging and monitoring.
• Prevent access to a keypad using a card and PIN function or allow card presentation to automatically login the user at the associated keypad.
•
Disarm an area associated with an elevator floor on access when using the destination reporting option or prevent the user from
gaining access to the floor based on the area status associated with
the floor.
• Arm large numbers of areas using area groups.
Integratred Access Control
The Protégé® SE Integrated System Controller provides a highly
sophisticated access control solution with large user capacity and
extensive features:
• Utilize primary and secondary access levels to manage users over simple scheduled periods and time zones.
•
Assign Door groups, Menu groups, Area groups, Floor groups and Elevator groups to an access level for flexible user management.
Each group can optionally access a secondary group to provide
multiple levels of user access.
Ethernet 10/100 Connection
•
System wide global anti-pass back, the Protégé® SE Integrated System Controller can maintain and control users area status
throughout the entire system with hard and soft anti-pass back
configuration options.
The Protégé® SE Integrated System Controller provides onboard
Ethernet communication to allow direct connection from a local PC or
interconnect to an existing LAN/WAN:
• Multiple card presentation options allows the use of access control cards, tags or other credentials to arm and disarm areas associated with doors.
• Directly connect the Protégé® System Management Suite across a LAN or WAN interface for instant connection and upload
download.
• Count users entering an area and arm the area when the count reaches a terminal number or deny access to users based on a
maximum user count.
•
IP reporting functionality using the Protégé® IP Reporting Protocol, Contact ID over IP, SIA over IP and full text reporting methods. The Protégé® IP Reporting Protocol requires the Protégé® IP Reporting
Bridge application operating on the remote machine or device with
a suitable communications driver for the automation software
being used.
Automation Functions
•
Full 10/100 compliant network interface allows the connection of the Protégé® SE Integrated System Controller to all networks at the
maximum capable signaling rate Indication of link status,
communication signaling rate and data transmission/reception shown on LED status indicators.
• Encrypted module network using RS-485 communication.
• 2x Wiegand or clock data readers providing two Entry/Exit Doors on-board (4 reader Multiplex Mode allows Entry and exit readers on each door).
Local Monitored Power Supply
The Protégé® SE Integrated System Controller operates from a 16VAC
input, utilizing a low cost transformer and providing a fully monitored
12VDC power solution using:
• Deep discharge prevention of the battery with automatic electronic
cut-off.
• Manual or processor controlled battery charge selection of 350mA or 700mA.
• Intelligent charging algorithm monitors battery and AC supply
allowing optimum performance to be achieved using standard lead
acid batteries.
Automation points can be controlled from the Protégé®
Alphanumeric LCD Keypad for the management of any controllable
device such as lighting, air conditioning and signage. Access directly
from the keypad the automation points allow a user interface to
specific programmable Outputs that a user can control.
Link automation points to programmable functions to provide
sophisticated control logic at the selection of an automation point.
Text names can be set for automation points allowing a scrollable list
of controllable items in the system such as ‘Office A/C’ or ‘Outside
Lights’.
Programmable Functions
Programmable functions allow for the use of special applications that
are configured in the Protégé® SE Integrated System Controller for
Logic, Area, Door and many other controllable devices:
• Process logic functions to allow complex equations to be
evaluated using the special internal memory registers and PGM Output status.
• Output of programmable functions can be directed to an action, memory region for storage and later use or a Programmable
Output.
• Monitored signals for ‘Battery Low/Disconnect’ and ‘AC Failure’
using local trouble zones.
• Inclusion of special applications to reduce installation time for the control and automation of garden lighting, external lighting and electronic movement sensors with auto manual operation.
Integrated Arming/Disarming
• Control of Doors, Areas, Elevators and PGM’s can be easily
programmed and managed.
The Protégé® SE Integrated System Controller features advanced
integration of arming and disarming solutions for control of up to 250 alarm areas:
• Deny access to a user based on the status of the area and the
ability for the user to control the area they are entering in turn reducing false alarms.
• Implement bank vault areas to control and manage the time
delayed access and unlocking of vault areas in banking facilities without the need for extra hardware control devices.
• Starting and stopping of functions allows them to be managed remotely as required including special run once options to allow manual control of a function that is controlled by an operator.
Connectivity and System Expansion
Integration
Expansion of the Protégé® System with the onboard local zone
(input) and PGM (Output) from the Protégé® SE Integrated System
Controller allows convenient cost effective expansion without the
increased cost of modules for simple system functions:
Link the Protégé® System with intelligent locking solutions through
Integrated Control Technologies comprehensive world class solution
partners:
• 16x onboard zone inputs each can be programmed to require EOL (End Of Line), Dual EOL or direct contact.
• 2x Bell/Siren Outputs with fully monitored operation.
• Use the Protégé® Alphanumeric LCD Keypad to expand the number of LCD keypads within an installation.
•
Zone expansion is provided on nearly all modules as part of the
Protégé® Systems integrated structure and provides a dual function for many of the zone input configurations. Use the Protégé® 16 Zone Input Expander to expand the number of zone inputs on the
Protégé® System.
•
Programmable Output expansion is provided directly on the
module network by the Protégé® 16 PGM Output Expander and incorporates 16x high current FORM C relays and fire control
functions.
•
Expand the access control reader connections in the Protégé®
System with the Protégé® Mini 2 Reader Expander, Protégé®
Intelligent 2 Reader Expander, Protégé® Standard 2 Reader
Expander or the Protégé® Ethernet 2 Reader Expander. All
providing two additional readers (4 Readers using entry/exit
configuration) and various options with local autonomous
operation, power supply and Ethernet options.
Communication
RS-485 communication interface for module communication, onboard
2400bps modem with dual line input and a 10/100 Ethernet
communications port gives a complete solution:
• Network RS-485 port used for all network communication
functions and interconnects to other modules with full galvanic isolation.
• On board 2400bps modem interface to allow all popular alarm
reporting formats and the ability for remote connection from the
Protégé® System Management Suite.
• 10/100Mbps Ethernet interface for communication with the
Protégé® System Management Suite and other applications and
functions.
d
an
ring ntre
ito Ce
Mon on
IP oma�
Aut
e
ptur
Ca
oto era
Ph Cam
ID
oto
Ph
ter
Prin
uter
l/Ro
wal
Fire
ic
CD mer
T-KL nu
PR lpha ad
A yp
égé® D Ke
Prot LC
uter
l/Ro
wal
Fire
em ient
Syst ite Cl
égé® t Su
Prot emen
ag
Man
E ed
RL-S grat
r
T-CT te
PR SE In rolle
nt
égé® Co
Prot System
int er
erpr Read
Fing ent
rolm
te
AN
N/W
LA
as
mer
Ca
En
t
rane
/Int k
or
rnet w
Inte Net
e2
on
ph
Tele
e Si
mot
Re
VR
ic
CD mer
T-KL nu
PR lpha ad
A yp
égé® D Ke
Prot LC
on
gra�
Inte
/N
DVR
e1
on
ph
Tele
E ed
RL-S grat
r
T-CT te
PR SE In rolle
nt
égé® Co
Prot System
r
te
u
Ro
all/
ew
Fir
ule
L
y SQ
db ring
Stan uste
Hot er Cl
Serv
cryp
ted
et
an
Intr
Mod
En
-PCB M
er
16 PG
T-PX 16
PR é® pand
ég Ex
Prot put
Out
CB
égé® t
Prot emen
ary
nd anag
Seco em M rver
Se
Syst
rnet
he
N Et
-P
16 PGM
er
T-PX 16
PR é® pand
ég Ex
Prot put
Out
E ed
RL-S grat
r
T-CT te
PR SE In rolle
nt
égé® Co
Prot System
CB
I2-P lligent
er
T-RD te
PR é® In pand
Ex
ég
Prot ader
2 Re
k
wor
Net
/LA
AN
gW
�n
Exis
nts
Clie
égé® t
Prot emen
ary anag
Prim M rver
em Se
Syst
cryp
ted
OX
PR
T-N ox
PR o Pr er
Nan Read
rd
Ca
B
PC Zone
ork
S16- rd 16
er
T-ZX da
PR Stan pand
Ex
égé® put
Prot In
etw
N
ule
Mod
En
ator
Elev
l
ntro
Co
OX
PR
T-N ox
PR o Pr er
Nan Read
rd
Ca
-PCB g
DC4 nalo
A
er
T-A
PR égé® pand
Prot put Ex
In
on
gra� ns
Inte lu�o
So
idity
Hum
-PCB
16 Zone
T-ZX 16 er
PR é®
nd
pa
ég
Prot put Ex
In
re
ratu
pe
Tem
ic
CD mer
T-KL nu
PR lpha ad
A yp
égé® D Ke
Prot LC
on
a�
tom
Au
rm
Ala
-PCB 2
E2 rnet
er
T-RD he
PR é® Et pand
Ex
ég
Prot ader
Re
Y-P
TR
-EN a
BIO prem Plus
Su ry
nt
Bioe
ic
CD mer
T-KL nu
PR lpha ad
A yp
égé® D Ke
Prot LC
-PCB
16 PGM
er
T-PX 16
PR é® pand
ég Ex
Prot put
Out
Clients Exis�ng WAN/LAN
TCP/IP Ethernet Connec�on
Encrypted RS-485 Module Network
OX
PR
T-N ox
PR o Pr er
Nan Read
rd
Ca
Encrypted RS-485 Module Intranet Network
Mul�plex Wiegand Data Communca�on
c
etri
Biom
ADSL/Fibre/Cable Internet Connec�on
Hot Standby Synchroniza�on and Clustering Path
PSTN Telephone Line
Modem Serial Interface
0-10V/4-20mA Industrial Sensor Input
Multifunction Reporting Services
Technical Specifications
Utilizing the latest functionality in communication services the
Protégé® SE Integrated System Controller incorporates a host of
communication options:
• Monitor telephone line inputs using the monitor phone service and
answer incoming calls on local modem interface using answer machine override and high security remote call back options.
• Report alarms using Contact ID, SIA Level 2.
•
Communicate with terminal programs using the Telnet Terminal
option and Output the data in ASCII, HEX with custom format
options and acknowledgement settings to allow connection of third party applications directly to the Protégé® SE Integrated System Controller.
• Send IP based reporting protocols using the onboard Ethernet communication interface and Protégé® IP Reporting Armor IP formats.
Operating Voltage
15.5 to 16.5VAC, 50-60Hz @ 40VA (Max)
Operating Current
280mA (Typical)
Total Combined Current
1.8A (Max)
DC Output (Auxiliary)
700mA (Typical) 1.1A (Max) Electronic
Shutdown at 1.1A
B1/B2 DC Outputs
(Continuous)
8 Ohm 20W Siren or 700mA (Typical)
B1/B2 DC Outputs (Inrush)
1000mA
Battery Charging
350mA/700mA
Battery Low
11.2VDC
Battery Restore
12.5VDC
Electronic Disconnection
8.76VDC
Communication (Ethernet)
1x 10/100Mbps Ethernet Communication Link
Communication (Serial)
1x Isolated RS-485 Communication Interface
Port 12VDC @ 28mA (Input)
Communication (Modem)
1x 2400bps Modem Communication
Readers
(Standard Mode)
2x Wiegand or clock data readers providing
one Entry/Exit Door or two Entry/Exit only
Doors
Readers
(Multiplex-reader Mode)
4x Wiegand Readers (connected in Multiplex
Reader mode) providing any combination of
Entry or Exit for two Doors
Zone Inputs (System Zones)
16x High Security Monitored Zone Inputs
Tamper Input
Dedicated Hardware Tamper Input
PGM Outputs
6x 50mA (Max) Open Collector Output for
reader LED and beeper or general functions
Status Output
1x 50mA (Max) Open Collector Output
Operating Temperature
0˚ to 55˚C (41˚ to 131˚F)
Storage Temperature
-10˚ to 85˚C (14˚ to 185˚F)
Humidity
0% to 85% (non condensing)
Dimensions (L x W x H)
234 x 183 x 35mm (9.21 x 7.20 x 1.37”)
Weight
790g (27.86oz)
Upgradable Firmware
Utilizing the latest flash technology and high performance
communication interface the firmware of the Protégé® SE Integrated
System Controller can be updated using industry standard
applications.
Electronic Bell/Siren Outputs
High current electronic monitored Bell/Siren control Outputs:
• Indication of Bell/Siren Outputs activation using LED. Bell/Siren
failure monitoring or lock disconnected (tamper) displayed as indicator and reported using trouble zone.
• Automatic shutdown on bell over current when activated or
shorted. Automatic restore on next deactivation/activation cycle.
Shutdown reported using trouble zone.
System Capacites
Standard Profile
Maximum
Users
2000
10000
Events
2000
4000
Schedules
128
248
Doors
16
128
Inputs
464
1104
Outputs
420
1108
16
64
8
32
Analog Expanders
8
16
Keypad Modules
32
48
Reader Expanders
8
64
Zone (Input) Expanders
PGM (Output) Expanders
The size of conductor used for the supply of all power to the Protégé® SE
Integrated System Controller should be adequate in size to prevent voltage
drop at the terminals of no more than 5% of the rated voltage.
Specifications are subject to change without notice, please visit
www.incontrol.co.nz for updated information.
Ordering Code
Description
PRT-CTRL-SE
Protégé® SE Integrated System Controller
Memory profiles increase the flexibility of the Protégé® System by providing a variety
of predefined or custom configurations to suite most installations. Please refer to the
Protégé® SE Integrated System Controller Installation Manual for more details.
Disclaimer:
Whilst every effort has been made to ensure accuracy in the
representation of this product, neither Integrated Control
Technology Ltd or any employee of the company, shall be
liable on any ground whatsoever to any party in respect
of decision or actions they may make as a result of using
this information. In accordance with the Integrated Control
Technology policy of enhanced development, design and
specifications are subject to change without notice.
Integrated Control Technology Limited
11 Canaveral Drive, Albany, North Shore City 0632, Auckland, New Zealand
P.O. Box 302-340, North Harbour, Auckland, New Zealand
Phone: +64 (9) 476 7124
Fax: +64 (9) 476 7128
Email: support@incontrol.co.nz
www.incontrol.co.nz
Designers and manufacturers of integrated electronic access control, security and building automation products.
Designed and manufactured by Integrated Control Technology Limited.
Copyright © Integrated Control Technology Limited 2003-2010. All rights reserved.
International Compliance Standards:
The Protégé® SE Integrated System Controller complies with
the following international standards. For an installation of
the Protégé® SE Integrated System Controller to comply with
any of the standards all installation procedures and
programming configuration settings must be made in
accordance with the required standard.
PENDING
ICT CODE: 245-8045-001 V: A102
Download PDF