AEC | AD SERIES | AEC - Q200-002 - Rev-B

AEC - Q200-002 - REV-B
June 1, 2010
Automotive Electronics Council
Component Technical Committee
ATTACHMENT 2
AEC - Q200-002 REV-B
HUMAN BODY MODEL ELECTROSTATIC DISCHARGE TEST
Page 1 of 14
AEC - Q200-002 - REV-B
June 1, 2010
Automotive Electronics Council
Component Technical Committee
NOTICE
AEC documents contain material that has been prepared, reviewed, and approved through the AEC Technical
Committee.
AEC documents are designed to serve the automotive electronics industry through eliminating
misunderstandings between manufacturers and purchasers, facilitating interchangeability and improvement of
products, and assisting the purchaser in selecting and obtaining with minimum delay the proper product for
use by those other than AEC members, whether the standard is to be used either domestically or
internationally.
AEC documents are adopted without regard to whether or not their adoption may involve patents or articles,
materials, or processes. By such action AEC does not assume any liability to any patent owner, nor does it
assume any obligation whatever to parties adopting the AEC documents. The information included in AEC
documents represents a sound approach to product specification and application, principally from the
automotive electronics system manufacturer viewpoint. No claims to be in conformance with this document
shall be made unless all requirements stated in the document are met.
Inquiries, comments, and suggestions relative to the content of this AEC document should be addressed to
the AEC Technical Committee on the link http://www.aecouncil.com.
Published by the Automotive Electronics Council.
This document may be downloaded free of charge, however AEC retains the copyright on this material. By
downloading this file, the individual agrees not to charge for or resell the resulting material.
Printed in the U.S.A.
All rights reserved
Copyright © 2010 by the Automotive Electronics Council. This document may be freely reprinted with this
copyright notice. This document cannot be changed without approval from the AEC Component Technical
Committee.
Page 2 of 14
AEC - Q200-002 - REV-B
June 1, 2010
Automotive Electronics Council
Component Technical Committee
METHOD - 002
PASSIVE COMPONENT
HUMAN BODY MODEL (HBM)
ELECTROSTATIC DISCHARGE (ESD) TEST
1.
SCOPE
1.1
Description:
The purpose of this specification is to establish a reliable and repeatable procedure for
determining PASSIVE COMPONENT HBM ESD sensitivity.
1.2
Reference Documents:
IEC 61000-4-2
ISO 10605
1.3
Terms and Definitions:
The terms used in this specification are defined as follows.
1.3.1
Component Failure:
A condition in which a component does not meet all the requirements of the acceptance criteria,
as specified in section 5 following the ESD test.
1.3.2
Device Under Test (DUT):
An electronic component being evaluated for its sensitivity to ESD.
1.3.3
Electrostatic Discharge (ESD):
The transfer of electrostatic charge between bodies at different electrostatic potentials.
1.3.4
Electrostatic Discharge Sensitivity:
An ESD voltage level which causes component failure.
1.3.5
ESD Simulator:
An instrument that simulates the PASSIVE COMPONENT human body model ESD pulse as
defined in this specification.
Page 3 of 14
AEC - Q200-002 - REV-B
June 1, 2010
Automotive Electronics Council
Component Technical Committee
1.3.6
Ground Plane:
A common electrical reference point for the DUT, ESD simulator, and auxiliary equipment.
1.3.7
Human Body Model (HBM):
A capacitance and resistance model that characterizes a person as a source of electrostatic
charging for automotive conditions, as shown in Figure 1, and the resulting ESD pulse meeting
the waveform criteria specified in this test method.
1.3.8
Maximum Withstanding Voltage:
The maximum ESD voltage at which, and below, the component is determined to pass the failure
criteria requirements specified in Section 4.
1.3.9
PUT:
PUT is the pin and/or terminal under test.
2.
EQUIPMENT:
2.1
Test Apparatus:
The apparatus for this test consists of an ESD pulse simulator with an equivalent PASSIVE
COMPONENT HBM ESD circuit as shown in Figure 1. The simulator must be capable of
supplying pulses which meet the waveform requirements of Table 1 and Figure 3 using the
coaxial target specified in Section 2.2.1.
High Voltage
Relay
Rch
100 Mohm
High Voltage
Source
Cd
Rd
Discharge
Tip
2000 ohm
150 pF
Stray
Capacitance
Discharge
Return
Connection
Direct Contact Adapter
(if applicable)
Ground Plane
Figure 1: Equivalent PASSIVE COMPONENT HBM ESD simulator circuit
Page 4 of 14
AEC - Q200-002 - REV-B
June 1, 2010
Automotive Electronics Council
Component Technical Committee
2.2
Measurement Equipment:
Equipment used to verify conformance of the simulator discharge waveform to the requirements
as specified in Table 1 and Figure 3 shall be either an analog oscilloscope with a minimum
bandwidth of 1.0GHz or a digital oscilloscope with a minimum sampling rate of 2 gigasamples per
second and a minimum bandwidth of 1.0GHz. Each instrument shall have 50Ω input impedance.
A faster oscilloscope (larger bandwidth and/or higher sampling rate) may be required to fully
characterize the ESD waveform.
2.2.1
Coaxial Target:
The coaxial target shall be a current-sensing transducer as specified by IEC 61000-4-2, or
equivalent. The target is used to verify the ESD simulator waveform as defined in Sections 2.3,
2.3.1, and 2.3.2.
2.2.2
Ground Plane:
The ground plane is a common electrical reference point with dimensional requirements of a 1mm
2
minimum thickness and a 1m minimum area. The ground plane is connected to earth ground by
a ground strap as short and as wide as possible; length ≤ 1m, width ≥ 5mm, and inductance ≤
2µH.
2.2.3
Probe:
The probe used to verify the ESD simulator charging voltage, as defined in Sections 2.3.2 and
2.4, shall be an electrometer probe with an input impedance ≥ 100 Gigohm.
2.2.4
20 dB Wideband Attenuator:
A 20 dB wideband attenuator may be required depending on the vertical sensitivity of the
oscilloscope. The attenuator shall be a 50Ω, 20dB wideband attenuator with a bandwidth of
20GHz and 2kW peak pulse power. When using the attenuator, it shall be attached to the output
of the coaxial target during the ESD simulator qualification and waveform verification as defined in
Sections 2.3 and 2.4.
2.3
ESD Simulator Qualification:
ESD simulator calibration and qualification must be performed during initial acceptance testing
and whenever the simulator is serviced. A period of six (6) months is the maximum permissible
time between full qualification tests. The ESD simulator must meet the waveform parameter
requirements for all voltage levels as defined in Table 1, Section 2.3.1, and Section 2.3.2. If at
any time the waveforms do not meet the requirements of Table 1 and Figure 3, the testing shall
be halted until waveforms are in compliance.
Page 5 of 14
AEC - Q200-002 - REV-B
June 1, 2010
Automotive Electronics Council
Component Technical Committee
2.3.1
Simulator Qualification Setup:
a.
The simulator qualification setup shall be configured according to the equivalent
schematic shown in Figure 2. Note that a 20dB wideband attenuator may be required as
shown in Figure 2 depending on the vertical sensitivity of the oscilloscope.
b.
The coaxial target shall be located on and bonded to the center of the ground plane. The
target output shall be connected to the oscilloscope through a 50Ω double-shielded, high
frequency, semi-rigid cable with length ≤ 1m. The cable shall not be looped and shall be
insulated from the ground plane.
c.
The horizontal time base and vertical amplifier level of the oscilloscope shall be
configured in order to view the risetime of the ESD waveform. The horizontal sweep shall
be set to single event trigger.
d.
The ESD simulator high voltage ground shall be directly connected to the ground plane by
a grounding strap with length ≤ 1m and an inductance ≤ 2µH. The ESD simulator shall be
set up and operated according to its instruction manual.
Coaxial Target
50 ohms
(distributed)
ESD Simulator
2 ohms
(distributed)
Ground Plane
20 dB (10X)
Attenuator
(if applicable)
50 ohms
Scope Input
Ground Plane
Figure 2: Equivalent schematic for Simulator Qualification
2.3.2
Simulator Qualification Procedure:
a.
To calibrate the display voltage of the ESD simulator, adjust the simulator voltage to the
desired level and polarity. With the electrometer in direct contact with the discharge tip
(see Figure 1), verify the voltage setting at levels of ± 500V, ± 1kV, ± 2kV, ± 4kV, ± 8kV, ±
12kV, ± 16kV, and ± 25kV. The electrometer reading shall be within ± 10% for voltages
from 200V to ≤ 25kV.
b.
For Direct Contact Discharge Qualification, discharge to the coaxial target at each voltage
level and polarity shown in Table 1. Record the risetime and first peak current values and
verify the parameters meet the requirements of Table 1. Figure 3 illustrates a typical
discharge waveform to a coaxial target. The simulator must meet the requirements of
Table 1 and Figure 3 for five (5) consecutive waveforms at all voltage levels.
Page 6 of 14
AEC - Q200-002 - REV-B
June 1, 2010
Automotive Electronics Council
Component Technical Committee
c.
2.4
For Air Discharge qualification, the ESD simulator shall be placed a distance of ≥ 15mm
from the coaxial target sphere. The ESD simulator, with the air discharge probe attached,
shall be held perpendicular (± 15°) to the target. From this position, the simulator air
discharge probe shall be slowly (≤ 5mm/second) moved towards the target until a single
discharge occurs. Only single event discharge waveforms shall be acceptable. Test
voltages for the air discharge are ± 12kV, ± 16kV, and ± 25kV. Figure 3 illustrates a
typical discharge waveform to a coaxial target. The slow approach method specified
above minimizes multiple discharges, discharges at lower voltage levels, and ringing in
the measurement equipment.
ESD Simulator Charge Verification:
The performance of the simulator can be dramatically degraded by parasitics in the discharge
path. Therefore, to ensure proper simulation and repeatable ESD results, ESD simulator charge
verification shall be performed before each daily use. With the electrometer in direct contact with
the discharge tip (see Figure 1), verify the voltage setting at levels of ± 500V, ± 1kV, ± 2kV, ± 4kV,
± 8kV, ± 12kV, ± 16kV, and ± 25kV. The electrometer reading shall be within ± 10% for voltages
from 200V to ≤ 25kV. If at any time the simulator charge does not meet the requirements of Table
1, the testing shall be halted until the simulator is in compliance and all ESD testing performed
since the last passing charge verification shall be considered invalid.
Table 1: Direct Contact and Air Discharge ESD Waveform Parameter Requirements
ESD Discharge Method
Direct Contact Discharge
Air Discharge
Indicated
Voltage
(kV)
First Peak
Current, Ip
(A)
Rise Time,
tr
(ns)
0.5 ± 0.05
1.87 +0.60/-0
0.7 to 1.0
1.0 ± 0.1
3.75 +1.12/-0
0.7 to 1.0
2.0 ± 0.5
7.50 +2.25/-0
0.7 to 1.0
4.0 ± 0.5
15.0 +4.50/-0
0.7 to 1.0
8.0 ± 0.8
30.0 +9.0/-0
0.7 to 1.0
25.0 ± 2.5
Not Specified
Not Specified
Page 7 of 14
AEC - Q200-002 - REV-B
June 1, 2010
Automotive Electronics Council
Component Technical Committee
Ip
90%
10%
t
tr
Time (ns)
Figure 3: Typical Direct Contact and Air Discharge PASSIVE COMPONENT HBM ESD Discharge
Waveform to a Coaxial Target
3.
TEST PROCEDURE:
3.1
Sample Size:
Each sample group shall be composed of 15 components, as specified in Table 1 of AEC-Q200.
Each sample group shall be stressed at one (1) voltage level using all pin and/or terminal
combinations specified in Section 3.2. The use of a new sample group for each stress voltage
level is recommended. It is permitted to use the same sample group for the next stress level if all
components in the sample group meet the acceptance criteria requirements specified in Section 5
after exposure to a specified voltage level.
3.2
Pin and/or Terminal Combinations:
Each pair of pins and/or terminals and all combinations of pin and/or terminal pairs for each
component shall be subjected to one (1) pulse at each stress voltage polarity following the ESD
levels stated in Figure 4. Any pin and/or terminal not under test shall be in an electrically open
(floating) state. A sufficient number of ESD levels must be tested to either: a) demonstrate the
component can pass a 25kV Air Discharge exposure, or b) determine the pass/fail transition
region between two (2) consecutive ESD test levels. If an expected failure level cannot be
estimated, the test flow diagram of Figure 4 may be used to minimize the amount of testing
required.
Page 8 of 14
AEC - Q200-002 - REV-B
June 1, 2010
Automotive Electronics Council
Component Technical Committee
3.3
Test Environment:
Each component shall be subjected to ESD pulses at 22°C ± 5°C. For all Air Discharge testing,
the relative humidity shall be 30% to 60%.
3.4
Measurements:
Prior to ESD testing, complete parametric testing (initial electrical verification) shall be performed
on all sample groups and all components in each sample group per applicable user device
specification at room temperature followed by hot temperature, unless specified otherwise in the
user device specification. If using an allowable parametric shift as failure criteria, a data log of
each component shall be made listing the applicable parameter measurement values. The data
log will be compared to the parameters measured during final electrical test verification testing to
determine the failure criteria of Section 4.
3.5
Test Setup:
a.
Ensure that the daily ESD simulator charge verification procedure (Section 2.4) has been
performed before applying discharges to the DUT.
b.
The ESD simulator high voltage ground shall be directly connected to the ground plane by
a grounding strap with a length ≤ 1m and an inductance ≤ 2µH.
c.
All DUT's are considered sensitive to ESD until proven otherwise and shall be handled
accordingly (reference internal procedures for proper handling of ESD sensitive
components).
d.
The DUT must pass complete parametric testing (initial electrical verification) as defined
in Section 3.4 prior to any application of ESD stress voltage levels.
3.6
Detailed Procedure:
3.6.1
Direct Contact Discharge:
a.
The ESD simulator shall be placed in direct contact with each PUT specified in Section
3.2.
b.
Each PUT within a sample group shall be tested at a stress voltage level specified in the
test flow diagram of Figure 4 using the Direct Contact discharge probe. Two (2)
discharges shall be applied to each PUT within a sample group and at each stress
voltage level, one (1) with a positive polarity and one (1) with a negative polarity.
c.
After each discharge to the PUT, residual charge remaining on the DUT shall be
dissipated by briefly connecting a one (1) megohm resistor between the PUT discharge
location and/or ground point of the DUT and the ground of the test setup.
d.
Repeat the procedure for all components within the sample group.
Page 9 of 14
AEC - Q200-002 - REV-B
June 1, 2010
Automotive Electronics Council
Component Technical Committee
3.6.2
e.
Using the next sample group, select another direct contact stress voltage level and repeat
the above procedure until all sample groups have been tested at a specified voltage level.
It is permitted to use the same sample group for the next stress voltage level if all
components in the sample group meet the acceptance criteria requirements specified in
Section 5 after exposure to a specified voltage level.
f.
Submit the components for complete parametric testing (final electrical verification) per
the user device specification at room temperature followed by hot temperature, unless
specified otherwise in the user device specification, and determine whether the
components meet the acceptance criteria requirements specified in Section 5. It is
permitted to perform the parametric testing (final electrical verification) per user device
specification after all sample groups have been tested.
Air Discharge:
a.
Using a new sample group, each PUT specified in Section 3.2 shall be tested at an air
discharge stress voltage level specified in the test flow diagram of Figure 4 using the Air
Discharge probe. It is permitted to use the same sample group for the next stress voltage
level if all components in the sample group meet the acceptance criteria requirements
specified in Section 5 after exposure to a specified voltage level.
b.
The ESD simulator shall be placed ≥ 15mm away from the PUT. The simulator, with the
Air Discharge probe, shall be held perpendicular to the PUT discharge location. The
probe shall be slowly moved towards the PUT (e.g., ≤ 5mm/second) until a single
discharge is obtained.
c.
If no discharge occurs, continue moving the probe towards the DUT until the simulator
discharge probe contacts the PUT discharge location. If the simulator makes contact with
the PUT discharge location and discharge occurs, discontinue testing at the stress
voltage level and location. A test board with closely spaced lead wires or metal runners
may prevent discharging to an intended PUT and result in an arcing phenomenon. When
this situation occurs, multiple test boards with a reduced number of lead wires or metal
runners shall be used.
d.
Two (2) discharges shall be applied to each PUT within a sample group at the air
discharge stress voltage level, one (1) with a positive polarity and one (1) with a negative
polarity.
e.
After each discharge to the PUT, residual charge remaining on the DUT shall be
dissipated by briefly connecting a one (1) megohm resistor between the PUT discharge
location and/or ground point of the DUT and the ground of the test setup.
f.
Repeat the procedure for all components within the sample group.
g.
Using the next sample group, select another air discharge stress voltage level and repeat
the above procedure until all sample groups have been tested at a specific voltage level.
It is permitted to use the same sample group for the next stress voltage level if all
components in the sample group meet the acceptance criteria requirements specified in
Section 5 after exposure to a specified voltage level.
Page 10 of 14
AEC - Q200-002 - REV-B
June 1, 2010
Automotive Electronics Council
Component Technical Committee
h.
4.
Submit the components for complete parametric testing (final electrical verification) per
the user device specification at room temperature followed by hot temperature, unless
specified otherwise in the user device specification, and determine whether the
components meet the acceptance criteria requirements specified in Section 5. It is
permitted to perform the parametric testing (final electrical verification) per user device
specification after all sample groups have been tested.
FAILURE CRITERIA
A component will be defined as a failure if, after exposure to ESD pulses, the component fails any
of the following criteria:
5.
1.
The component exceeds the allowable shift value. Specific parameters and allowable
shift values shall be defined in the applicable user device specification. During initial
parametric testing, a data log shall be made for each component listing the applicable
parameter measurement values. The data log will be compared to the parameters
measured during final parametric testing to determine the shift value. Components
exceeding the allowable shift value will be defined as a failure.
2.
The component no longer meets the user device specification requirements. Complete
parametric testing (initial and final electrical verification) shall be performed per applicable
user device specification.
ACCEPTANCE CRITERIA:
A component passes a voltage level if all components stressed at that voltage level pass. All the
samples used must meet the measurement requirements specified in Section 3 and the failure
criteria requirements specified in Section 4. Using the classification levels specified in Table 2,
classify the components according to the highest ESD voltage level survived during ESD testing.
The ESD withstanding voltage shall be defined for each component by the supplier.
Page 11 of 14
AEC - Q200-002 - REV-B
June 1, 2010
Automotive Electronics Council
Component Technical Committee
Table 2: PASSIVE COMPONENT HBM ESD Classification Levels
(DC = Direct Contact Discharge, AD = Air Discharge)
Component Classification
Maximum Withstand Voltage
1A
< 500 V (DC)
1B
500 V (DC) to < 1000 V (DC)
1C
1000 V (DC) to < 2000 V (DC)
2
2000 V (DC) to < 4000 V (DC)
3
4000 V (DC) to < 6000 V (DC)
4
6000 V (DC) to < 8000 V (DC)
5A
8000 V (DC) to < 12,000 V (AD)
5B
12,000 V (AD) to < 16,000 V (AD)
5C
16,000 V (AD) to < 25,000 V (AD)
6
≥ 25,000 V (AD)
Page 12 of 14
AEC - Q200-002 - REV-B
June 1, 2010
Automotive Electronics Council
Component Technical Committee
6 kV
Direct Contact
FAIL
PASS
2 kV
12 kV
Direct Contact
FAIL
1 kV
1 kV
DC
500 V
FAIL
< 500 V
DC
FAIL
8 kV
Direct Contact
PASS
Direct Contact
PASS
4 kV
Direct Contact
FAIL
Air Discharge
FAIL
2 kV
DC
Direct Contact
PASS
4 kV
DC
FAIL
6 kV
DC
PASS
8 kV
DC
PASS
16 kV
Air Discharge
FAIL
PASS
12 kV
AD
25 kV
Air Discharge
PASS
FAIL
500 V
DC
16 kV
AD
PASS
> 25 kV
AD
Note 1: Classify the components according to the highest ESD voltage level survived during ESD testing.
Figure 4: PASSIVE COMPONENT HBM ESD Test Flow Diagram
(DC = Direct Contact Discharge, AD = Air Discharge)
Page 13 of 14
AEC - Q200-002 - REV-B
June 1, 2010
Automotive Electronics Council
Component Technical Committee
Revision History
Rev #
Date of change
-
April 30, 1996
A
March 15, 2000
B
June 1, 2010
Brief summary listing affected sections:
Initial Release.
Removed CDF designation throughout document. Removed Chrysler,
Delco, and Ford logo from each page header. Added Component
Technical Committee to each page header.
Notice Statement (Page 2) Added. Format Updated.
Page 14 of 14