Daewoo FRS-T24FA Series Service manual

Add to my manuals
59 Pages

advertisement

Daewoo FRS-T24FA Series Service manual | Manualzz

S/M No. :

Caution :

In this Manual, some parts can be changed for improving, their performance without notice in the parts list. So, if you need the latest parts information,please refer to PPL(Parts Price List) in

Service Information Center (http://svc.dwe.co.kr).

http : //svc.dwe.co.kr

C O N T E N T S

1. External size

2. Refrigeration cycle

3. Cold air circulation

4. Name of each parts

..................................................................................................

..................................................................................................

..................................................................................................

..................................................................................................

5

6

2

4

1. Specificatin

2. Electric parts

3. Door color code

..................................................................................................

..................................................................................................

..................................................................................................

8

9

13

1. Display

- OPERATION AND FUNCTION -

..................................................................................................

2. Temperature control of FC

..................................................................................................

..................................................................................................

3. Temperature control of RC

4. Sleep mode

..................................................................................................

5/6. Silent/Control of each mode

7. Defrosting cycle

..................................................................................................

..................................................................................................

8. Defrosting mode

9. Error display

..................................................................................................

..................................................................................................

10/11. Forced/Initial defrosting

..................................................................................................

12/13. Buzzer/LCD Background light

14/15/16. Explanation after delivery/Prevention of Comp. restart/Back up function

17. Delay function

..................................................................................................

18/19/20. Home bar heater/Control of interior lights/Demo function

21. Reg. of R-sensor off point

..................................................................................................

22. Summary

23. Automatic icemaker

24. Dispenser control

..................................................................................................

..................................................................................................

..................................................................................................

14

17

18

20

21

25

27

28

31

32

33

34

35

35

36

39

1. Wiring diagram

- DIAGRAM -

..................................................................................................

2. Circuit wiring diagram

..................................................................................................

41

43

1. Installation preparation

2. How to install water line

3. Leveling & Adjustment

..................................................................................................

..................................................................................................

..................................................................................................

45

47

50

1. FRS-T24DA* Exploded view

2. FRS-T24DA* Parts List

3. FRS-T24FA* Exploded view

4. FRS-T24FA* Parts List

- EXPLODED VIEW-

..................................................................................................

..................................................................................................

..................................................................................................

..................................................................................................

51

57

63

69

SAFETY AND PRECAUTION

1) For starters, be sure to check any chances of the leakage of electricity

2) You could handle a part in the vicinity of electricity after unplugging

3) You should put on rubber glovers to prevent an electric shock on operation test

4) Make sure the rated current, voltage, capacity before using an instrument

5) Keep your wet hands away from the metal goods in the freezer compartment not to be frostbitten

6) Be careful not to let water to permeate the electric part in the machine room

EXTERNAL VIEWS

1. EXTERNAL SIZE

2

EXTERNAL VIEWS

3

EXTERNAL VIEWS

2. Refrigeration Cycle

MSZ 70* NF (HB)

Welding Points

Flow of Refrigeration Cycle

5%

35%

High

7 points

5 point

Low

4

EXTERNAL VIEWS

3. Cold Air Circulation

Freezer

Compartment

Refrigerator

Compartment

5

EXTERNAL VIEWS

4. NAME OF EACH PART

FRS-T24DA*

1

2

3

4

5

6 1

Freezer

1. Ice cubes storage case

2. Freezer light

3. Water/Ice Dispenser

4. Freezer shelve

5. Freezer pocket

6. Freezer case

Refrigerator Compartment

7. Dairy pocket

8. Deordorizer

9. Refrigerator light(A)

10. Wine holder

11. Chilled case

12. Refrigerator shelve

13. Movable Egg case

14. Refrigerator pocket

15. Refrigerator case

6

12

13

10

11

7

8

9

4

15

EXTERNAL VIEWS

1

2

3

4

5

6

FRS-T24FA*

1

Freezer

1. Ice cubes storage case

2. Freezer light

3. Water/Ice Dispenser

4. Freezer shelve

5. Freezer pocket

6. Freezer case

Refrigerator Compartment

7. Dairy pocket

8. Deordorizer

9. Refrigerator light(A)

10. Wine holder

11. Chilled case

12. Refrigerator shelve

13. Movable Egg case

14. Refrigerator pocket

15. Refrigerator case

16. Refreshment room(Pocket)

7

7

8

9

10

11

16

12

13

4

15

SPECIFICATIONS

1. SPECIFICATIONS

MODEL NAME

ISO Gross Volume (L)

DIVISION

ISO Storage Volume (L)

EXTERNAL

DIMENSION (mm)

REFRIGENT

COOLING & CONTROL

SYSTEM

NET WEIGHT (kg)

FREEZER

REFRIGERATOR

TOTAL

FREEZER

REFRIGERATOR

TOTAL

WIDTH

DEPTH

HEIGHT

R134a

COOLING SYSTEM

DEFROST SYSTEM

DEFORST CONTROL

CONTENTS

FRS-T24DA*

231

425

656

209

394

603

928

883

1808

190

Fan Cooling System

Fin Evaporator Forced

Automatic Start & Stop

143

FRS-T24FA*

145

8

SPECIFICATIONS

2. ELECTRIC PARTS

1) COMPRESSOR

REFRIGERANT

VOLTAGE ( V/HZ)

COMP MODEL

PART CODE

STARTING TYPE

2) RELAY

REFRIGERANT

VOLTAGE ( V/HZ)

ASSY

PTC

OVER LOAD

TYPE NAME

PART CODE

RESISTANCE

PART CODE

100 /50,60

X

X

X

100 /50,60

X

X

X

X

3) STARTING CAPACITOR

REFRIGERANT

VOLTAGE ( V/HZ)

PART CODE

RATED VOLTAGE

RATED CAPACITANCE

100 /50,60

X

X

X

4) RUNNING CAPACITOR

REFRIGERANT

VOLTAGE ( V/HZ)

PART CODE

RATED VOLTAGE

RATED CAPACITANCE

5) F-FAN MOTOR

REFRIGERANT

VOLTAGE ( V/HZ)

TYPE NAME

PART CODE

REVOLUTION

6) R-FAN MOTOR

REFRIGERANT

VOLTAGE ( V/HZ)

TYPE NAME

PART CODE

REVOLUTION

100 /50,60

X

X

X

100 /50,60

100 /50,60

110 / 60

HBL27YG-3

3952127R30

CSR

115,120/60

X

X

X

R134a

127/60

HCL27YG-2

3957127R20

CSIR

220 / 60

HPL27YG-4A

3956127R40

RSCR

110 / 60

783SHB

3018119370

6.8

783SHB

115,120/60

X

X

X

X

R134a

127/60

801SFB

3018118180

6.8

801SFB

110 / 60

3016400100

200V

100

115,120/60

X

X

X

R134a

127/60

3016400100

200V

100

110 / 60

400EL15130

230V

10 §

115,120/60

X

X

X

R134a

127/60

X

X

X

220 / 60

419RHB

3018118131

33

419RHB

220 / 60

X

X

X

220 / 60

3016401170

350V

110 / 60 115,120/60

R134a

127/60

BL-2213DWFA-1

3015911300

DC 12V 2200RPM

220/60

110 / 60 115,120/60

R134a

127/60

BL-2213DWRA-1

3015911400

DC 12V 2200RPM

220/60

220 ~240/50

HPL30YG-5

395S130R50

RSCR

230 /50

(EUROP)

MK183Q-L2U

3956183D50

RSCR

220~240 / 50

308NHB

3018119980

33

308NHB

230 / 50

265RHB

3018125210

33

265RHB

220~240 / 50

X

X

X

230 / 50

X

X

X

220~240 / 50

3016401920

400V

230 / 50

3016401170

350V

220~240 / 50 230 / 50

220~240 / 50 230 / 50

9

SPECIFICATIONS

7) C- FAN MOTOR

REFRIGERANT

VOLTAGE ( V/HZ)

TYPE NAME

PART CODE

REVOLUTION

8) DEFROST HEATER

REFRIGERANT

VOLTAGE ( V/HZ)

SPEC (W)

PART CODE

100 /50,60 110 / 60 115,120/60

R134a

127/60

BL-2213DWCA-2

3015911500

DC 12V 2200RPM

12) FUSE (PCB)

REFRIGERANT

VOLTAGE ( V/HZ)

RATED CURRENT

PART CODE

100 /50,60

X

X

100 /50,60

X

X

110 / 60

140W

3012811210

110 / 60

250V/3.15A

5F3GB3282R

115,120/60

9) DRAIN HEATER

REFRIGERANT

VOLTAGE ( V/HZ)

SPEC (W)

PART CODE

10) LAMP ASSEMBLY

REFRIGERANT

VOLTAGE ( V/HZ)

SPEC (W)

PART CODE

SPEC (W)

PART CODE

100 /50,60

X

X

100 /50,60

X

X

X

X

110 / 60

110V 10W

3012811110

115,120/60

110 / 60

120V 15W

3013600070

120V 25W

3013602020

115,120/60

11) MAIN PCB ASSEMBLY

REFRIGERANT

VOLTAGE ( V/HZ)

TYPE NAME

PART CODE

100 /50,60 110 / 60

X SBS 2ND PREMIUM

X 30143D2060

115,120/60

115,120/60

R134a

127/60

R134a

127/60

R134a

127/60

R134a

127/60

R134a

127/60

220/60

220/60

140W

3012811200

220/60

220V 10W

3012811100

220/60

240V 15W

3013600060

230~240V 25W

3013602010

220/60

220/60

220~240 / 50 230 / 50

220~240 / 50 230 / 50

220~240 / 50 230 / 50

220~240 / 50 230 / 50

220~240 / 50 230 / 50

30143D2070

220~240 / 50 230 / 50

10

SPECIFICATIONS

13) THERMOSTAT FUSE

REFRIGERANT

VOLTAGE ( V/HZ)

OPERATING TEMPERATURE

PART CODE

14) MOTOR GEARED AS

REFRIGERANT

VOLTAGE ( V/HZ)

SPEC

PART CODE

100 /50,60 x x

100 /50,60 x x

110 / 60

77

30127201400

115,120/60

R134a

127/60

110 / 60

120V/60Hz

3015914000

115,120/60

R134a

127/60

220/60

220/60

220V/60Hz

3015912800

220~240 / 50 230 / 50

220~240 / 50

230V/50Hz

3015913900

230 / 50

15) VALVE SOLENOID DISPENSER

REFRIGERANT

100 /50,60 VOLTAGE ( V/HZ)

SPEC

PART CODE x x

110 / 60

110~115V/60Hz

3015403200

115,120/60

R134a

127/60

127V/60Hz

3015403100

220/60

220V/60Hz

3015402100

220~240 / 50

230V/50Hz

3015403000

230 / 50

16) VALVE SOLENOID CRUSHER

REFRIGERANT

100 /50,60 VOLTAGE ( V/HZ)

SPEC

PART CODE x x

110 / 60

110~127V 60Hz

3015402900

115,120/60

R134a

127/60 220/60

220~240V 50,60Hz

3015402000

220~240 / 50 230 / 50

17) VALVE WATER

REFRIGERANT

VOLTAGE ( V/HZ)

SPEC

PART CODE

100 /50,60 x x

110 / 60

110~127V 60Hz

3015402800

115,120/60

R134a

127/60 220/60

220~240V 50,60Hz

3015402200

220~240 / 50 230 / 50

11

SPECIFICATIONS

18) POWER CORD

NO SHAPE OF POWER CORD

1

PART CODE

3011315000

DESCRIPTION

CP-2PIN

REMARK

For european country

4

5

2

3

6

401RA17200 CP-2PIN For other country

4006D17101

401PD17101

KP-30

KP-211

3011300801 BP-3PIN

3011303010 # 267

For America & El Salvador

For Japan & Taiwan

For Chile

7

8

3011315310

3011303050 BS-1363A

For Israel

For U.K, Middle Asia

Singapore & Malaysia

9 3011301200 KP-551/550 For China & Australia

Upper power cord's part code is only lead wire, without any kinds of terminal or houisng

12

SPECIFICATIONS

3. Door Color Code

1) Assembly Freezer Door

- FRS-T24FA* / FRS-T24DA* (100~120V)

Blowing Agent

Color Type

Color Code

Part Code

NOBLESS SILVER

NAH4A

300003974A

NEO WHITE

NHH4G

300003971A

- FRS-T24FA* / FRS-T24DA* (127V/60Hz)

Blowing Agent

Color Type

Color Code

Part Code

NOBLESS SILVER

NAH4A

300003974B

NEO WHITE

NHH4G

300003971B

- FRS-T24FA* / FRS-T24DA* (220V/60Hz)

Blowing Agent

Color Type

Color Code

NOBLESS SILVER

NAH4A

NEO WHITE

NHH4G

Part Code

3000039740 3000039710

- FRS-T24FA* / FRS-T24DA* (220~240V/50Hz)

Blowing Agent

Color Type

Color Code

Part Code

NOBLESS SILVER

NAH4A

300003974C

NEO WHITE

NHH4G

300003971C

2) Assembly Refrigerator Door

- FRS-T24FA* (100~127V)

Blowing Agent

Color Type

Color Code

NOBLESS SILVER

NAH4A

Part Code

300003944A

NEO WHITE

NHH4G

300003941A

- FRS-T24FA* (200~240V)

Blowing Agent

Color Type

Color Code

Part Code

NOBLESS SILVER

NAH4A

3000039440

- FRS-T24DA*

Blowing Agent

Color Type

Color Code

Part Code

NOBLESS SILVER

NAH4A

3000039540

NEO WHITE

NHH4G

3000039410

NEO WHITE

NHH4G

3000039510

Cyclo Pentane

LUXURY MIRROR CHERRY WOOD

LMH4G CWH4W

300003972A 300003973A

Cyclo Pentane

LUXURY MIRROR CHERRY WOOD

LMH4G CWH4W

300003972B 300003973B

Cyclo Pentane

LUXURY MIRROR CHERRY WOOD

LMH4G CWH4W

3000039720 3000039730

Cyclo Pentane

LUXURY MIRROR CHERRY WOOD

LMH4G CWH4W

300003972C 300003973C

Cyclo Pentane

LUXURY MIRROR CHERRY WOOD

LMH4G CWH4W

300003942A 300003943A

Cyclo Pentane

LUXURY MIRROR CHERRY WOOD

LMH4G CWH4W

3000039420 3000039430

Cyclo Pentane

LUXURY MIRROR CHERRY WOOD

LMH4G CWH4W

3000039520 3000039530

THE OTHERS

THE OTHERS

300003970A

THE OTHERS

THE OTHERS

300003970B

THE OTHERS

THE OTHERS

3000039700

THE OTHERS

THE OTHERS

300003970C

THE OTHERS

THE OTHERS

300003940A

THE OTHERS

THE OTHERS

3000039400

THE OTHERS

THE OTHERS

3000039500

13

OPERATION AND FUNCTIONS

1. DISPLAY

INPUT

Front PCB buttons

FRZ SET. button

REF SET. button

SUPER FRZ. button

SUPER REF. button

WATER / ICE button

LOCK Button / SLEEP button

LCD

CONTENTS

Control Object

1. Normal Operation

1) Temperature control of Freezer / Refrigerator

( Initial mode : Freezer & Refrigerator Middle )

2) Lock mode / Sleep mode / Ice maker Lock : OFF

3) SPEED icon : inactive

4) FUZZY & DEODORIZER letters and icons : always ON

5) Water / Cube Ice / Crushed Ice

( Initial mode : Water )

6) Other display modes

CUSTOM LCD

Normal Operation

Normal

Mode

Load Mode

Silent Mode

Silence

Mode

Freezer / Refrigerator BAR DIAL DIAL DIAL DIAL

DIAL DIAL DIAL Temp. SEG. DIAL

1) Letters of [FRZ., REF ., LOW,

HIGH, SET TEMP, FUZZY,

DEODO., SILENT, SLEEP,

WATER]

2) Icons of [FUZZY, DEODO.,

SLEEP, Water]

3) Temp. bars and lines

ON ON ON

Sleep

Mode

DIAL

DIAL

ON ON

SILENT icon OFF OFF ON ON OFF

SPEED letters OFF ON ON OFF OFF

SPEED bars

LOCK ON/OFF, SLEEP

ON/OFF

Water / Cube Ice / Crushed Ice

OFF

DIAL

DIAL

ON

(progressive)

ON

(progressive)

DIAL DIAL

DIAL DIAL

OFF OFF

DIAL DIAL

DIAL DIAL

14

OPERATION AND FUNCTIONS

CONTENTS

2. "FRZ SET." button

Temperature control of Freezer compartment

5 steps of sequential temperature mode

Initial mode by power input : "MID" (Temperature and bars are shown.)

* Letters are not indicated at Soft-Mid and Mid-Strong modes.

(Just Setting temperatures and bars are shown.)

Temperature progress : Low (Low-Mid) Mid (Mid-High) HIgh

Temp. indication : -15 C -17 C -19 C -21 C -25 C

3. "SUPER FRZ." button

When this mode is chosen, "QUICK" icon and letters of freezer flicker 6 times and

ON. (The set temperature and bars are still the previous value.)

4. "REF. SET" button

Temperature control of Refrigerator compartment

5 steps of sequential temperature mode

Initial mode by power input : "MID" (Temperature and bars are shown.)

Letters are not indicated at Soft-Mid and Mid-Strong modes.

(Just temperatures and bars are shown.)

Temperature progress : Low (Low-Mid) Mid (Mid-High) HIgh

Temp. indication : 4 C 3 C 2 C 1 C 0 C

5. "SUPER REF." button

When this mode is chosen, "QUICK" icon and letters of refrigerator flicker 6 times and ON. (The set temperature and bars are still the previous value.)

6. "SLEEP" button

Start by pushing the button ("ON" lights.)

Stop by pushing button again ("OFF" lights.)

Automaticcally terminated after maximum 12 hours ("OFF" lights.)

7. Water/Ice button

Select Water mode or Ice mode.

A rectangle Line around the icon lights up to indicate your selection is on.

Initial mode by power input: "Water"mode.

Progress: Water Cube Ice Crushed Ice Water

8. "LOCK" button

Start by pushing the button ("LOCK" letters and icon light.)

*No other buttons and modes, buzzer sound are controllable.

Stop by pushing button again for a second ("OFF" and icon light.)

* Except "Lock"button, other buttons are inactive during "Sleep"mode.

REMARK

15

OPERATION AND FUNCTIONS

CONTENTS

9. "ICE MAKER LOCK" button

Start by pushing "ICE MAKER LOCK"button

"ICE MAKER LOCK" is "ON",

The Icon & Box of "Cube Ice"/"Crushed Ice"disappear,

"Water"Icon & Box is always "ON"

Stop by pushing "ICE MAKER LOCK"button again.

"ICE MAKER LOCK" Icon is "OFF",

The Icon & Box of "Cube Ice"/"Crushed Ice"is "OFF",

"Water"Icon & Box is "ON".

10. Filter information

The normal("OK" Icon) is on for 6 month after first power input.

After six month, "CHANGE" Icon is on.

How to reset Filter information.

REMARK

16

OPERATION AND FUNCTIONS

2. Temperature Control of Freezer Compartment (FC)

INPUT Control Object

1. FRZ. SET button

2. SUPER FRZ. button

3. F-sensor

CONTENTS

1. Temperature modes change by pushing the button.

Low Low-Mid Mid

1. COMP

2. F-FAN

REMARKS

2. Comp. and F-fan are controlled by ON / OFF point of each mode.

3. Freezer Compartment [ON / OFF] DIFF : 2

( Freezer middle OFF point : -20.0 )

C

4. Freezer Compartment [Low

(

5. Control point of each mode

C

Mid-High

C

High

(Low-Mid) Mid (Mid-High)] DIFF : 2 degrees respectively

Temp.

-1 4.0

-1 6.0

-1 6.0

-1 8.0

-1 8.0

-2 0.0

-2 0.0

-2 2.0

-2 4.0

ON point

ON/ OFF DIFF

-2 6.0

OFF point

Low

STEP DIFF

(Low-Mid) Mid

STEP DIFF

(Mid-High) High

MODE

17

OPERATION AND FUNCTIONS

CONTENTS

6. SUPER FRZ. (Quick Freezing)

1) Comp. and F-fan are ON (about 150 minutes) regardless of F-sensor.

2) F-fan runs at 14V for the first 90 min., then at 12V for the rest time.

F/S

F Fan

90min.

14V

60min.

12V

REMARKS

* ON/OFF DIFF. : fixed by MICOM

* STEP DIFF. : fixed by MICOM

* Comp. and C-fan :

linked

SUPER FRZ. start F-fan RPM change point

Normal operation

3. Temperature Control of Refrigerator Compartment (RC)

INPUT Control Object

1. REF. SET button

2. R-sensor

CONTENTS

1. Temperature modes change by pushing the button.

Low Low -Mid

1. COMP

2. R-FAN

Mid Mid-High High

2. R-fan are controlled by ON / OFF point of each mode.

3. Refrigerator Compartment [ON / OFF] C

C ) ( Refreigerator Compartment middle OFF point : 0.7

C point : 2.7 )

4. Refrigerator Compartment [Low

: 1 degree respectively

C

(Low-Mid) Mid (Mid-High)] DIFF

5. Prevention of weak/poor-refrigeration

1) When weak refrigeration is sensed, comp. is ON regardless of F-sensor.

2) When R-sensor reaches R-fan OFF point, comp. is controlled by F-sensor and

R-fan turns OFF.

3) Sensing point of weak refrigeration : R-sensor OFF point of each mode + 7

4) Termination point : Same as R-sensor OFF point of each mode

C

REMARKS

* ON/OFF Diff. : fixed by MICOM

* STEP DIFF. : fixed by MICOM

18

OPERATION AND FUNCTIONS

CONTENTS

6. Control point of each mode

Temp

9.7

C

8.7

C

7.7

C

6.7

C

5.7

C

Weak refrigeration point

(Off point+7 )

3.2

C

2.2

C

2.7

C

1.7

C

Low

STEP DIFF

(Low-Mid)

1.2

C

0.7

C

Mid

0.2

-0.3

C

C

STEP DIFF

(Mid-High)

-0.8

ON point

C

OFF point

-1.3

C

ON/OFF

DIFF

(0.35 deg)

MODE

High

7. Super refrigeration proceeds for 40 minutes.

* Example of temperature change

(Refrigerator ; Low (normal) -> Super refrigeration )

REMARKS

1) R-fan and comp. are ON until R-sensor reaches to over-refrigeration OFF

C

2) After reaching to the point, it goes on with HIGH mode until the end of

Super refrigeration.

It returns to normal after Quick refrigeration of 40 minutes.

19

OPERATION AND FUNCTIONS

4. Sleep Mode

INPUT Control Object

1. SLEEP button

1. COMP

2. R-FAN

3. F-FAN

4. CUSTOM-LCD

CONTENTS

1. This mode starts with a push of SLEEP button.

2. Conditions to start Sleep mode

C F-sensor = -13

Unless it is a restart within 40 minutes after the end of previous Sleep mode

F-sensor error

Door switch error

Defrosting (Heater defrosting, pause, Fan delay)

If the above conditions of ~ are all satisfied, the sleep mode starts.

3. Control of electrical parts

1) Mode 1

Once Sleep mode starts, all the electrical parts (COMP, F-FAN, R-FAN) turn OFF.

("ON" letters of SLEEP on LCD is display.)

2) Mode 2

It operates in Silent mode and "ON" letters of SLEEP on LCD is displayed on.

4. Termination of Sleep mode

1) MODE 1

C

In case of F-sensor error

When other button is pushed during this mode

Total F/R door open time exceeds 30 seconds during the mode

If Sleep mode is terminated by , and , F/R-fan delay for 5 minutes and restart of this mode is prevented for 40minutes.

If it exceeds time limit of 130 minute, Mode1 is terminated and Mode2 starts.

2) MODE 2

Sleep mode is terminated 12 hours after the first start.

( Speed mode and defrosting operate in normal way.)

5. After Sleep mode stops all the electrical parts return to normal operation and Sleep icon changes from "ON" to "OFF".

6. If Sleep mode starts during PRECOOL, it goes on again after the Sleep mode is terminated.

7. If Sleep mode starts during Super FRZ., Super REF., it returns to previous set mode after the Sleep mode is terminated.

REMARKS

20

OPERATION AND FUNCTIONS

5. SILENT (Silence Mode)

INPUT Control Object

1. CDS SENSOR

1. COMP

2. R-FAN

3. F-FAN

4. CUSTOM-LCD

CONTENTS

1. Purpose of Silence mode

To reduce refrigerator noise at night by decresing fan RPM to a minimum degree

2. Condition to start

The optical or light sensor in top middle of control panel senses surround light and Silence mode starts if the amount of light sensed is below the standard value

for more than 1 minute.

(The mode does not start for initial 240 minutes to prevent down of cooling performance.)

- Standard value to decide "night" : below 5 ~7 Lux (optical sensor surface)

- Standard value to decide "daytime" : above 4~16 Lux

(optical sensor surface)

3. Control Method

Control Mode F-FAN R-FAN C-FAN

REMARKS

Silence

Normal

Load

Control

10V

12V

10V

12V

10V

12V

4. Termination Condition

The mode stops if lux value is above the standard for more than 1 minute.

6. Control of Each Mode

INPUT Control Object

1. CDS SENSOR

2. R SENSOR

3. F SENSOR

1. F-FAN (14V, 12V, 10V)

CONTENTS

Control of Silence mode : operation mode when the optical sensor feels that it is night

Normal control : daytime operation mode

(Refrigerator noise is relatively low at daytime.)

Load control : operation mode when inside temperature goes up due to an increase of load (foods) or frequent door openings.

REMARKS

21

OPERATION AND FUNCTIONS

CONTENTS

1. Fan voltage of each control mode

Control Mode F-FAN R-FAN C-FAN

Load Control

Silence

Normal 12V 12V

Sleep Mode2

Normal

Silence

Normal

12V

Normal

Load control

10V

10V

12V

2. Control against (under) load (Load Control)

14V

12V

10V

10V

12V

5) Control Method

5-1) Control mode by F/R-door open time (over 30 seconds)

F/R-fan works by 14V respectively.

5-2) Control mode by [F-sensor On Point + 5 degree]

F-fan works by 14V.

5-3) Control mode by [R-sensor On Point + 5 degree]

R-fan works by 14V.

C-fan works by 10V as normal.

10V

1) Purpose : To restore F/R-temperature which has risen by load (much foods in or frequent door openings) as soon as possible

2) Display : "SPEED" lights until the mode and speed icons flicker.

3) Conditions to start (from both Normal and Silence)

F or R door open time exceeds 30 secon d load control starts respectively .

Over [F-sensor On Point + 5 degree] F load control

Over [R-sensor On Point + 5 degree] R load control

4) Conditions to avoid load control

Initial operation (right after power input, Just after Pre-cool, Heater defrosting,

Pause, Defrosting cycle.)

(After door opening, the load control enters if the condition complies with.)

(During Sleep Mode1, load control isn t active.)

6) Conditions to stop

The mode works for 20 minutes.

(If another condition happens at the end of the mode, it starts again.)

When it reaches to [F-sensor Off point], F-fan load control mode stops.

When it reaches to [R-sensor Off point], R-fan load control mode stops.

REMARKS

22

OPERATION AND FUNCTIONS

CONTENTS

3. Control Time Chart of Each Mode

1) Start & stop of load control mode (Normal Control)

Door

On + 5deg

F/S

F Fan

14V

12V

20min.

On + 5deg

R/S

12V

14V

20min.

R Fan

Ref. Load

Door Open

30s after Door

Open

Frz. Load stop

Ref. Load stop

Load Mode Start

Frz. Stop ; after 20min.

Frz. Start Condition

Frz. Overload Input

2) Start & stop of load control mode (Silence Control)

Door

On + 5deg

F/S

F Fan

12V

10V

20min.

On + 5deg

R/S

R Fan

8V

Door Open

30sec. after open

Frz. Load Stop

Ref. Load Stop

Load Mode Start

Frz. Load Start

Frz. Overload Input

3) Start & stop of load control mode (Normal defrosting control)

20min.

12V

Ref. Load

Frz. Stop Condition ; after 20min.

H T R

F /S

C om p

F F an

R /S

R F an

12V

D e f ro s tin g S ta rt

20m in.

N o rm al O p e ratio n

8V

O n + 5deg

14V

C o n d itio n to s ta rt L o ad

M o d e , b u t avo id e d b u rin g d e f ro s tin g m o d e

Re f . Lo a d Sto p

Re f . Lo a d M o d e

REMARKS

23

OPERATION AND FUNCTIONS

4. Flow Chart of Load Control Mode

Start

CONTENTS

Y

Freezer

Compartment

Overload

Y

Refrigerator

Compartment

Overload

Load control is avoided ?

N

F/R door open time is over 30 sec. ?

N

F/S ON + 5deg?

N

R-sensor ON + 5deg?

N

Overload mode ?

Y

Overload mode control

F load control; over 20min?

N

F- sensor OFF point ?

N

R load control; over 20 min?

N

R-sensor OFF point?

N

End

Y

Y

Y

Y

N

Y

Overload of both compartments

Y

F load control mode stop

R load control mode stop

Normal mode control

REMARKS

24

OPERATION AND FUNCTIONS

7. Defrosting Cycle

INPUT

1. Total comp. work time

2. Comp. work rate

3. RT temperature

4. Total door open time

Control Object

1. Defrosting Mode

CONTENTS

1. Conditions to start defrosting cycle

1) Total comp. work time : 6, 8, ........ 24 hours.

2) Total door open time : 3 minutes

(Any door - F or R - open time is over 3 minutes.)

3) Total time of [comp. ON + comp. OFF] : 60 hours

4) Any error mode : R1, F1, D1, F3, RT/S, Door-switch

2. Conditions to start defrosting mode

1) The mode starts with the following conditions ;

Any error happens when total comp. work time is 6 or 8....... or 24hours.

Total door open time is over 3 minutes.

(Any door - F or R - open time is over 3 minutes.)

2) Defrosting mode starts unconditionally as long as total comp. work time is 24 hours, even if the above conditions( ~ ) are not satisfied.

3) Defrosting mode starts immediately as long as total time of [comp. ON + comp. OFF] is over 60 hours, even if the above 1) and 2) conditions are not satisfied.

Remark

25

OPERATION AND FUNCTIONS

3. Flow Chart of Defrosting Start

CONTENTS

Start

Yes

Yes

Yes

Yes

Defrosting mode starts.

Comp. work time is over 2 hours ?

Yes

Total time is over 60 hours ?

No

Comp. work time is over 24 hours ?

No

Comp. work time is over 6 hours ?

Yes

Total door open time is over 3 minutes ?

No

Any error ?

No

End

No

No

REMARKS

26

OPERATION AND FU NCTIONS

8. Defrosting Mode

INPUT

1. Defrosting Cycle

1. Defrosting Mode

Pre-Cool

CONTENTS

1. COMP

2. F-FAN

3. R-FAN

4. HEATER

Control Object

REMARKS

1) Time ; 50 minutes

2) Comp. / F-fan : ON

R-fan : Control

Heater : OFF

3) If F-sensor C

Heater

Defrosting

Pause

Fan Delay

1) Comp. /F-fan / R-fan : OFF

HTR : ON

2) Time limit

30 seconds : Heater is ON regardless of D-sensor temperature right after defrosting start.

30 minutes : in case of D1-Error

80 minutes : in normal control state

C , Heater Defrosting is OFF

1) Time : 7 minutes

Comp./ F-fan / R-fan / Heater / Homebar HTR : OFF

1) Time : 5 minutes

Comp. : ON

F/R-fan, Heater : OFF

27

OPERATION AND FUNCTIONS

9. Error Display (LCD Display of Front PCB)

INPUT Control Object

1. Temperature Control Buttons LCD

CONTENTS

1. How to start

1) Press "crushed ice" button 5 times while pressing "water" button at the same time.

2) Push "super freeze" button 5 times while pushing"freezer set" button at the same time.

2. Display

Error code is displayed on LCD.

3. How to stop

1) Push "reset water filter " button 1 time.

2) It stops automatically in 4 minutes from the start.

4. All the error Codes are reset if they turn to be normal.

5. Error Code

ERROR CODE CONTENTS

F1

F-sensor ; disconnection, short.

r1 R-sensor ; disconnection, short. rt

RT-sensor ; disconnection, short.

EF

Et

E9

ES

EA

Eu

Co d2 d1 dr dF dH

C1

F3

E1

D-sensor ; disconnection, short.

R-Door Switch ; defective

F-Door Switch ; defective

Homebar (Refreshment Center) Door Switch ; defective

Cycle ; abnormal or defective.

Return after defrosting ; abnormal or defective

I senser ; defective

F senser ; defective

Horizontal switch ; error

Water supply ; error

Micro switch ; error

Drop the ice while Et

Full ice switch ; error

Display Full-Down mode

Display forced defrost mode for A/S

REMARKS

28

OPERATION AND FUNCTIONS

CONTENTS

6. Control way of Errors (if any)

1) "F1" ERROR

Cause : F-sensor disconnection / short

Control : Condition of ambient temperature

RT/S ~13 C ~29 C

Work rate

ON/OFF

14/ 50 16 / 41 27 / 45 26 / 22

If F-sensor is normal, the error is terminated automatically. over 29 C

35 / 20

2) "r1" ERROR

Cause : R-sensor disconnection / short

Control : Condition of ambient temperature

RT/S ~13 C ~29 C ~39 C

Work rate

ON/OFF

OFF 3 / 50 2 / 10 3 / 7

If R-sensor is normal, the error is terminated automatically.

4 / 6

3) "rt" ERROR

Cause : RT-sensor disconnection / short (pull-down)

Control : Normal operation, deletion of control condition by RT-sensor

If RT-sensor is normal, the error is terminated automatically. over 39 C

6 / 4

4) "d1" ERROR

Cause : D-sensor disconnection / short (pull-down)

Control : Time limit (30min.) of defrosting-return

If D-sensor is normal, the error is terminated automatically.

5) Door ERROR("dF","dR","dH" on display)

Cause : in case it senses that door is open for more than 1 hour.

Control : Deletion of function related door switch sensing

If door switch (open & close) is sensed, the error is terminated automatically.

6) "C1" ERROR

Cause : in case comp. works for over 3 hours when D-sensor temp. is over -5

Control : Normal operation

C

C

When D-sensor temp. is below -5 in comp. OFF, it is terminated.

7) "F3" ERROR

Cause : in case defrosting-return is done by time limit of 80min.

Control : Deletion of Pre-cool mode in defrosting mode

If defrosting-return is done by D-sensor, it is terminated.

8) "d2" MODE (A/S forced defrosting mode)

Push " fridge set " button 5 times while pushing "freezer set ." button simultaneously.

Control : A/S forced defrosting control (Pre-cool is deleted.)

C

REMARKS

29

OPERATION AND FUNCTIONS

CONTENTS

9) "EI" ERROR

Cause : I-SENSOR disconnection / short

Control : After water suppy, Ice drop every 4.8hour.

Termination : When I-SENSOR is normal.

10) "EF" Error

Cause : When Flow-sensor is ERROR(There is no Pulse during some time.)

The number of pulse signal is below 10 by 1 sec during water supply.

Control : Control by time (By Vector time recorded EEPROM.)

(Generally, Water is supplied about 5.5s.)

11) "E9" Error

Cause : I-Sensor temp(5min after Water supply) doesn't go up.

Control : Normal control

Termination : Normal condition

12) "ES" Error (Micro S/W Error)

Cause : When it senses 1min continuously .

Control : Stop Dispenser & Crusher function.

Display : Relative LED is flicker.

Termination : Normal condition

13) Malfunction of Ice Drop Motor

Cause : Malfunction of Ice Drop Motor.

[Check the Motor by pushing Test S/W.]

Termination : Exchange Motor

14) "Eu" Error

Cause : Switch(which senses if the ice is full or not) is in Error.

Control : When dropping the Ice, the motor just rotates 90 degree.

Termination : When the switch is in normal.

15) "EA" Error

Cause : When sensing Ice dropping by time 3times in level sensor SW Error.

Control :Stop of Ice Maker.

Termination : With normal level switch.

* Reinput of power or push of icemaker test switch.

16) "Et" ERROR

Cause : Level switch error (No pulse is sensed for some time.)

Control : By time. ( Supply mode is skipped.)

Te rmination : Normal condition.

* When all ERROR CODE is normal, the Refrigerator reset.

REMARKS

30

OPERATION AND FUNCTIONS

10. Forced Defrosting

INPUT Control Object

1. "FRZ. SET" Button

2. "REF. SET." button

3. "LOCK" button

Defrosting Mode

CONTENTS

1. How to start

Set "LOCK ON" first, then push "REF. SET" button 5 times while pushing "FRZ. SET" button simultaneously.

2. How to proceed

1) Delete Pre-cool mode. (Others are same as normal defrosting.)

2) Heater is ON regardless of D-sensor temp. at first 30 seconds.

( Check of defrosting current)

11. Initial Defrosting

INPUT Control Object

REMARKS

D-sensor

Initial or first power input (power plugin)

CONTENTS

Defrosting Mode

If D-sensor temp. 3.5 , defrosting mode starts from Pre-cool at first power input.

C

REMARKS

Comp. is delayed for 6 min. at the initial defrosting.

12. Buzzer or Alarm

INPUT Control Object

F-PCB buttons

Door Switch

Initial Power Input

BUZZER

CONTENTS REMARKS

1. Buzzer sounds if any button of F-PCB is pushed.

2. Buzzer sounds 4 times, 3 seconds after initial power input.

3. Buzzer sounds 3 times in case of A/S forced defrosting, 1 time in case of Pull Down operation.

(Door open alarm)

4. If door is open, buzzer sounds every 1 minute for 5 minutes.

13. LCD Background Light

INPUT

F-PCB buttons

Door Switch

Initial Power Input

LCD BACK LIGHT

Control Object

31

OPERATION AND FUCTIONS

1. Conditions to turn on LCD Light

CONTENTS

1) Power input (plugin)

2) When any button on the panel is pushed, first the back light turns on, then button control is done.

3) When F/R door is open, the light turns on.

2. Conditions to turn off the light

1) The back light turns off 10 seconds after F/R door is closed

2) 1 minute after button control

REMARKS

14. Explanation After Delivery

INPUT Control Object

"FRZ. SET" button

"REF. SET" button

Power Cord

Electrical components and LCD

CONTENTS

1. Start

Push "REFRIGERATOR SET." button for 3 seconds within 10 seconds just after power input.

2. Control

1) Electrical components are OFF for 3 hours.

2) Display operates in normal way.

REMARKS

15. Prevention of Compressor Restart

INPUT

None

CONTENTS

Comp. does not start again for 6 minutes though F-sensor is ON.

Control Object

Comp.

REMARKS

6min. delay

16. Back Up Function

INPUT

None

Control Object

CONTENTS

1. Filter Exchange Information : Record as a realtime from the point of Power

Input.

2.P FACTOR (Information about Ice Maker)

REMARKS

32

OPERATION AND FUNCTIONS

17. Delay Function of Electric Components

INPUT

COMP ON/OFF

COMP

F-FAN

CONTENTS

1) F-fan delay by comp. ON/OFF

F-fan is ON/OFF 1 minute after comp. is ON/OFF.

Control Object

REMARKS

1 min.

2) F an Delay and Priority

O N c o n d i tio n

O F F

O F F

O F F

1 min.

O N

0 . 5 s e c .

O N

1 . 0 s e c .

O N

1 . 5 s e c .

R F A N

F F A N

C F A N

33

OPERATION AND FUCTIONS

18. Home Bar (Home Bar Models Only) Heater

INPUT

None Comp.

CONTENTS

It is linked with comp.

19. Control of Interior Lights

INPUT

Refrigerator Door

Freezer Door

Home-Bar Door (Home Bar Models Only)

COMP

Control Object

Control Object

CONTENTS

1) Control of Refrigerator Compartment Lights

R lights turn ON/OFF by R-door switch (ON/OFF).

10 minutes after sensing door open, the lights turn off automatically though door close is not sensed.

2) Control of Freezer Compartment Lights

F lights turn ON/OFF by F-door switch (ON/OFF). y though door close is not sensed.

3) R-lights ON/OFF by Home Bar(Home Bar Models Only) door opening

R-lights turn ON for 1 minute after sensing HOME-BAR switch open.

(If the switch is pushed again within 1 minute, the light turns on another

1 minute.)

4) DISPENSER LAMP CONTROL

DISPENSER LAMP turns ON/OFF by DISPENSER SW.

Dispenser Lamp turns ON for 5 seconds after sensing switch close.

20. Demonstration Function

INPUT Control Object

"LOCK" button

"REFRIGERATOR SET." button

"SLEEP" button

COMP

F-FAN

R-FAN

CONTENTS

1. Start

1) Set "LOCK ON" first.

2) Push "SLEEP" button 5 times while pushing "REF SET." button simultaneously.

2. Control

1) All other electrical components are OFF except for F-fan / R-fan.

2) Fan Control

DOOR OPEN FAN ON / DOOR CLOSE FAN OFF

3) Display : Normal mode (3sec.) SPEED(3sec. ) Super mode(3sec.)

Silent mode(3sec.) Sleep mode (3sec.)

3. Stop or Termination

1) During Demo mode push "SLEEP" button 5 times while pushing "REF SET." button simultaneously.

2) Power in again.

REMARKS

REMARKS

REMARKS

34

OPERATION AND FUNCTIONS

21. Regulation of R-sensor OFF Point

J1, J2 on Main PCB

INPUT

CONTENTS

Control Object

Resistance of R-sensor Mid ON/OFF Point

REMARKS

Regulation of R-sensor OFF point (1.5degree DOWN)

In case refrigeration of refrigerator is weak or insufficient, take the following action.

RSENSOR

R36

R37

R38

R36 : R-SENSOR standard resistance in normal mode (31.4K )

R37 : In case of weak ref., cut J1 to down the standard resistance by 1.5deg(2K)

R38 : In case of weak ref., cut J2 to down the standard resistance by 1.5deg(2K)

R36 = Mid ON/OFF point

R36 + R37 = Mid OFF point - 1.5 deg

R36 + R37 + R38 = Mid OFF point - 3.0 deg

22. Summary of Function

CONTENTS

How to start function modes

All the modes are started with "LOCK ON".

A/S forced defrosting

Pull down Functions

ERROR display

EERROM Clear

Reset water filter

DEMO function

"FRZ SET." + "REF SET." 5 times.

"FRZ SET." + "REF SET." + "SLEEP" 5 times.

"REF SET." for 3 sec. Right after first power in.

"FRZ SET." + "SUPER FRZ." 5 times.

"SLEEP" + "LOCK" 5 times.

"ICE MAKER LOCK" for 3 sec.

"REF SET." + "SLEEP" 5 times.

35

OPERATION AND FUNCTIONS

23. Automatic Ice Maker

Input

Full ice sensing switch

Ice Maker Lock

Sensors

CONTENTS

1-1. Flow of ice making

START

Ice separating motor

Control Object

REMARKS

Ice making

Mode

ICE is being made. water supply stand-by

Ice separating

Mode

Ice tray is twisted to separate ice cubes.

Water supply

Mode

Water is supplied to ice tray.

Water supply

Check Mode

Check if water is supplied OK.

RETURN

1) Press TEST switch of Icemaker for more than 1 second and test mode starts.

* Test mode starts from ice separating mode.

* In case test switch has an error of short, test is done only once.

2) With the initial power input, Ice tray turns to be horizontal and ice making mode starts.

3) Control of water hose heater

* Heater is always ON if RT-sensor has an error or RT is below 15 degree.

* Heater is always ON for 60 minutes (max. limit time) if Flow-sensor has an error.

4) Water supply stand-by

Condition ; if ice is sensed full.

Operation : proceeds to Ice making mode ( Ice separating and water supply modes stop.)

Termination ; if it is in normal condition.

5) Crusher Function

It stops operation when freezer door is open.

It operates if freezer door is closed.

36

OPERATION AND FUCTIONS

1-2. Ice Maker MODE

START

CONTENTS

NO

130 min passed?

YES

I-S<-9.5

C

NO

I-S<-12.5

C

YES

NO

YES

15 min passed?

YES

NO

ICE Drop mode.

1)

2) Although I-S isn't -12.5 below for 130 min, I-S maintains -9.5 below continuously

=> Ice maker comlpete

C C

3) I-Sensor Error: Ice Maker Complete after 4.8HR

2. Ice Drop MODE status

Ice tray

Start ICE DROP level

8-11 sec Max 1.1

sec 8.5-12.2

sec level normal level c.w

10 sec c.c.w

11 sec

1) Each Section’s Time used in S/W ERROR Confirm

2) Ice Drop MOTOR Rotation is Sensible by Each Sections

3) S/W ERROR: Ice Drop Every Time

4) Ice Drop MOTOR ERROR: Stop to the Status

0.2

sec c.w

1.1 sec stop

REMARKS

37

OPERATION AND FUNCTIONS

OPERATION AND FUNCTIONS

3. Water-Input MODE

CONTENTS

START

Inlet value ON

Water input pulse Count=0

N

Y

Water input pulse >10

Y

N

Flow-Sensor Error mode

N

Water input pulse >target pulse

N time> target time

Y

Y

Inlet value off

STOP

1) Convert of Water-Input Mode After Ice Drop:

Water-Input Valve Open.

2) Flow Sensor Error: Water-Input is Controlled by Time

3) Veriable Factor Value : Using for A/S Steps

!

Flow Sensor Normal Operation : Flow Pulse Value sets "238"

(Water input by Time -: Maximum Water Inut Time => 15 sec.

@ Flow Sensor error : Water input time => 5.5 sec.

4.

Water-Input Confirm MODE

I-S Temp. Rising Value with RT-S Temp. Mode after 5 min. : Estimate of Water Input

RT-S 7 C

I-S -10 C

~13

-9

C

C

~19

-8

C

C

~29 C

-7 C

~39

-6

C

C

39

-5

C

C

38

REMARKS

OPERATION AND FUCTIONS

24. Dispenser Control Function

Input

Dispenser SW

Water/Ice Button

Lock Ice Maker Button

Freezer Door SW

1) Water/Ice Selection Button

* Initial Mode : Water

Progress : Water Ice Cube

Contents

Crushed Ice

Control Object

Dispenser Lamp

Crusher Motor

Flat Solenoid

Crusher Solenoid

Dispenser Water Valve

Water

* Pushing the dispenser value, water/Ice cube/crushed Ice is dispensed as your selection.

2) Lock Ice Maker Button

Start by pushing "Lock Ice Maker" button

" Lock Icer Maker" is "ON",

The Icon & Box of "Cube Ice"/"Crushed Ice" disappear,

"Water"Icon & Box is always "ON"

Stop by pushing "Lock Ice Maker" button again.

"Lock Icer Maker" Icon is "OFF",

The Icon & Box of"Cube Ice"/"Crushed Ice"is "OFF",

"Water"Icon & Box is "ON".

3) Display

- Initial Mode : Water ICON & Letter is "ON".

- A rectangle Line around the icon lights up to indicate your selection is on.

- The Icon of water, Ice Cube, Crushed Ice is always " ON".( Exception, Dispenser

S/W Error)

- When pushing ' Lock Ice Maker':

Lock Ice Maker is "ON" , The letters of crushed, cube Ice are "OFF"

- There is no input during 1 hour, Dispeser transform into Water Mode.

Remark

39

OPERATION AND FUNCTIONS

Contents

3) Control Flow & Timing Chart

3-1) Crushed Ice

D.P SW

D.P Lamp

D.P S/V (Flap)

Crusher Motor

3-2) Cubed Ice

D.P SW

D.P Lamp

Cube S/V

D.P S/V (Flap)

Gear Motor

3-3) Water

D.P SW

D.P Lamp

Water S/V

A

A

A

A

A

A

Delay Time : A = 500ms, B = 500Ms, C = 2.0s, D = 5.0s

C

D

B

C

D

D

Remark

40

DIAGRAM

1. WIRING DIAGRAM

< RSCR TYPE >

41

DIAGRAM

< CSR TYPE >

42

DIAGRAM

2. CIRCUIT WIRING DIAGRAM

Main PCB

43

DIAGRAM

FRONT PCB DIAGRRAM

44

INSTALLATION GUIDE

1. Installation Preparation

Check if the refrigerator can pass a doorway or enter a door first.

Dimensions( including Door Handles)

(Width*Depth*Height)

942mm 883mm 1812mm

Find a suitable place to install

Sufficient space from refrigerator back to the wall for free air ventilation

Avoid direct sunlight.

Once the installation place is ready follow the installation instructions.

If surround temperature of refrigerator is low (below 5 ), foods can be frozen or the refrigerator can work in abnormal way.

45

INSTALLATION GUIDE

If the refrigerator can not enter the door, follow these steps.

Removing Freezer Door

1 Remove the bottom cover first.

Pull out the left collar of the coupling first, then hold the coupling and pull out the left water tube.

Remove front bottom cover first, if it is attached.

2 Unscrew top hinge cover with a screw driver.

Insert a thin screw driver into the side groove of the cover to remove.

3 Turn top hinge fastener counterclockwise 3~4 times.

Disconnect the harness wires.

4 Lift up the front of hinge to remove.

( After the hinge is removed the door can fall down forward. Be careful !)

5 Be careful not to damage the water line when removing the door.

Removing Refrigerator Door

1 Unscrew top hinge cover with a screw driver.

Insert a thin screw driver into the side groove of the cover to remove.

2 Turn top hinge fastener counterclockwise 3~4 times.

Disconnect harness wires.

3 Lift up the front of hinge to remove.

(After the hinge is removed the door can fall down forward. Be careful !)

4 Lift the door straight up to remove.

46

INSTALLATION GUIDE

2. How to install water line

How to install Water Line

1. The water pressure should be 3kgf/cm 2 or more to run the automatic icemaker.

Checkup your tap water pressure ; if a cup of 180cc is full within 10 seconds, the pressure is OK.

2. When installing the water tubes, ensure they are not colse to any hot surfaces.

3. The water filter only filters water ; it does not eliminate any bacteria or microbes.

4. If the water pressure is not so high to run the icemaker, call the local plumber to get an additional water pressure pump.

5. The filter life depends on the amount of use. We recommend you replace the filter at least once every 6months.

When attaching the filter, place it for easy access (removing

& replacing)

6. After installation of refrigerator and water line system, select

[WATER] on your control panel and press it for 2~3 minutes to supply water into the water tank and dispense water.

7. Use sealing tape to every connection of pipes/tubes to ensure there is no water leak.

8. The water tube should be connected to the cold water line.

WATER SUPPY KIT

Check the parts below for installing water supply.

Some other necessary parts are available at your local service agents.

Connector A,B,C

(3014454510)

(3012020700)

(7112401211)

(3010541600)

3011202000

(A:3019503200

B:3019503300)

Installation Procedure

1. Join Connector to the tap water line

1) First lock the main tap water valve.

Check if connector B and C has its own rubber packing ring in it.

2) Join Connector-C to the water tap, then Connector -B to connector -C with a wrench or spanner.

3) Insert water pipe into Connector-B and join Connector-A with a wrench or spanner.

4) In case Connector-C does not fit water tap join Connector-B directly to the tap.(See Figure B.)

If no connector fits water tap, call your local service.

5) Unlock main tap water valve, open tap water and check if any water leaks on each joins.

Place the rubber washer inside the tap connector and screw onto the water tap.

2. Get ready to install the Water Filter

1) Measure an approximate distance between the filter and the

Water Tube and cut the tube off filter vertically.

2) Connect the tubes to the filter as the figure shows.

Leave a sufficient distance when cutting the tubes.

<Figure A>

<Figure B>

47

INSTALLATION GUIDE

3. Remove any substances in the filter.

1) Open the main tap water valve and check if water comes out of the Water Tube.

2) Check if the Water Valve is open in case water does not come out.

3) Leave the valve open until clean water is coming out.

Initial water may contain some substances out of filter

(manufacturing process).

4. Attach the Filter Box

1) Screw and fasten the filter holder to the left/right side of the back of refrigerator.

In case the holder is not fastened well, remove the back paper of the tape on the filter holder and attach it."

2) Insert the filter box into the holder.

Connector

Tap

5. Connect the Water Tube to the refrigerator.

1) Remove the rear cover at the bottom back of the refrigerator.

2) Insert the fastening ring into the Water tube.

(Be careful to follow the direction of the nut.)

3) Insert the Water Tube into the top of Water Valve, turn the nut clockwise to fasten it. (The Water valve is to the right of the motors.)

4) Check for any bent tubes or water leaks; if so, re-ckeck instalation procedure.

5) Replace the rear cover. (The Water Tube should be placed between the groove of the refrigerator back and motor cover.)

Set the tube upright as the figure shows.

6. Fasten the Water Tube.

1) Fasten the Water Tube with the [Fastener A] .

2) Check if the tube is bent or sqeezed. If so, set it right to prevent any water leak.

Water Tube

Fastener A

Water Tube

Water Tube

Nut

Water Valve

7. After installation of Water Supply System

1) Plug the refrigerator, press the [WATER] button on the control panel for 2~3 minutes to remove any air (bubble) in the pipes and drain out the initial water.

2) Check the water leak again through the water supply system

(tubes, connectors and pipes) Rearrange the tubes again and do not move the refrigerator.

Connector

Tap

Water Tube

48

INSTALLATION GUIDE

1

Replacing Freezer Door

Insert the water tube into the hole of the bottom hinge pin first, then

Insert the bottom of freezer door into the bottom hinge pin.

2 Insert the bottom hole of freezer door straight to the bottom hinge pin.

3 Let the top of door close to the cabinet and insert the top hinge pin to the top hole of freezer door.

( Insert the back of hinge to the groove of protrusion first, then front to the top hole of door.)

4 Turn the hinge fastener tightly to the end.

Connect harness wirings and screw ground wire.

5 Insert the water tube far into the coupling.

Replacing Refrigerator Door

1 Insert the bottom hole of refrigerator door straight to the bottom hinge pin

2 Let the top of door close to the cabinet and insert the top hinge pin

to the top hole of freezer door

( Insert the back of hinge to the groove of protrusion first, then front to the top hole of door.)

3 Turn the hinge fastener tightly to the end.

Connect harness wirings and screw ground wire.

Click and screw the top hinge cover.

49

INSTALLATION GUIDE

Refrigerator Leveling &

Door Adjustment ( If needed. )

Refrigerator must be level in order to maintain optimal performance and desirable front appearance.

(If the floor beneath the refrigerator is uneven, freezer and refrigerator doors look unbalanced.)

In case freezer door is lower than refrigerator door ...

1 Insert a screw driver (flat tip) into a groove of the left wheel (bottom of freezer) and turn it clockwise until the door is balanced. (clockwise to raise freezer door ; counterclockwise to lower)

Unless the freezer door is balanced by step 1, then follow the next steps.

2 Open the doors, unscrew the front cover and remove, if it is attached.

3 Loosen 3 hinge bolts(1 on the left + 2 on the right) a little. (Do not unfasten them completely.) Insert a hexagonal wrench into the groove of adjusting nut and turn clockwise until the door is level.

4 Once the door is balanced, fasten the hinge bolts tightly and screw the front cover.

Hinge Bolt

Caution

The front of refrigerator needs to be higher just a little than the back for easy door closing, but if the wheel is raised too much for door balance, i.e. front of refrigerator is too higher than the back, it can be difficult to open the door.

1

In case refrigerator door is lower than freezer door ...

Insert a screw driver (flat tip) into a groove of the right wheel (bottom of refrigerator) and turn it clockwise until the door is balanced. (clockwise to raise refrigerator door ; counterclockwise to lower)

Unless the refrigerator door is balanced by step 1, then follow the next steps.

2 Loosen 3 hinge bolts(2 on the left + 1 on the right) a little. (Do not unfasten them completely.)

Insert a hexagonal wrench into the groove of adjusting nut and turn clockwise until the door is level.

3 Once the door is balanced, fasten the hinge bolts tightly.

Front Cover

After installation and/or door leveling, fasten front cover with screws.(Remove the screws on the front bottom panel first. Click and screw the cover)

Attaching of W ater Filter Holder

Remove the back paper of the tape on the filter holder and attach the filter holder on a suitable place.

50

Exploded View & Parts List

Model

FRT-551D~/FRS-T20DA*

FRT-551F~/FRS-T20FA*

FRT-581B~/FRS-T20BA*

FRT-581H~/FRS-T20HA*

FRT-661D~/FRS-T24DA*

FRT-661F~/FRS-T24FA*

FRT-691B~/FRS-T24BA*

FRT-691H~/FRS-T24HA*

Cabinet

NO PART-CODE PART NAME SPEC.

Q'ty

20BA* 20HA* 20DA* 20FA*

24BA* 24HA* 24DA* 24FA*

3

6

7

9

1

2

10

12

13

14

15

17

28

31

32

33

18

19

20

21

22

27

ASSY CAB URT

3012908100 HINGE *T *R AS

3012907400 HINGE *T *L AS

3011472400 COVER HI *T *R

3011472300 COVER HI *T *L

3012601302 HANDLE CAB COVR *R

3012601202 HANDLE CAB COVR *L

3010533400 BOX M/PCB

3016401170

3016401610

3016401920

400EL15130

CAPACITOR RUN

30143B4024

30143C4041

3013223401

3013223420

PCB MAIN AS

30143C4050

3011472610 COVER M/PCB BOX

HOSE I/MAKER TUBE AS

FR-T690DG

FR-T690DG

PP

PP

PP(CAVITY 1*4*2)

PP(CAVITY 1*4*2)

PP(FB-72)

350VAC 5UF(EUROPEAN)

250VAC/12UF EPOXY WIRE

400VAC 5UF(WIRE)

230V-10UF

FR-S580CG (ISO)

FR-T660DD(SAA)

FR-T660DD(MEXICO)

PP(V-235)

220~240V

110~127V

3012519200 GUIDE CAB W/TUBE A AS FR-S660CW

3011485600 COVER GUIDE CAB W/TUBE A HIPS

3011202000 CLAMP TUBE

3012907304 HINGE *U *R AS

3012907203 HINGE *U *L AS

3012104410 FOOT ADJ AS

PA-66,5N

PO T5 BK PAINT

PO T5 BK PAINT

FR-T690FGS

3010654510 BRACKET ADJ FOOT AS

3013064200 HOLDER TUBE A

3011494010 COVER CAB BRKT AS

3019974020 S/PART W/TUBE AS

SPCC T2.6

A5UC5

COVER+CAP

EXPORT MODEL(POM)

1

1

1

1

1

1

1

1

1 x

1 x x x

1 x

1

1

2

2

1

1

1

1

1

1

1

1

1 x

1 x x

1

1

2

2 x

1 x

- Some parts can be chaged for improving their perfomance without notice.

- Above parts number doesn't describe your own colour & printing. Please remind!

1

1

1

1

1

1

1

1 x

1

1

1

2

2

1

1

1

2

2

1

1

1

1

1

1

1

1

1

1

1 x

1

1

1

2

2

1

1

1

2

2

1

1

1

Date A mendment Note

1

Machine Room / Eva Parts

NO PART-CODE PART NAME SPEC.

36

38

41

42

43

44-1

3010326702 BASE COMP AS

7 page CORD POWER AS

3956190F50

3952127R30

3957127R20

3956127R40 COMPRESSOR

395S130R50

3956183D10

3956183D50

3016002500 SPECIAL WASHER

3010101600 ABSORBER COMP

7page SWITCH P RELAY AS

FR-S690FRI(VE)

DH90LHP5 220V-240V 50HZ

HBL27YG-3 110V 60HZ

HCL27YG-2 127V 60HZ

HPL27YG-4-N 220V 60HZ

HPL30YG-5-N 220/240V 50HZ

MK183C-L2U 110-115V-60HZ

MK183Q-L2U 220-240V-50HZ

SK-5 T0.8

NBR

44-2

45

46

47

48

56

3811400503

3811402100

COVER RELAY

3011181310 CASE VAPORI AS

3013201710 HOSE DRN B

3014461530 PIPE WICON AS

3018500410 M/BELL AS

VALVE WATER AS

DAEWOO COMPRESSOR

SAMSUNG COMPRESSOR

FRS-551F PP(NATURAL)

PE FRB-5970NB

TSW OD4.76XT0.7

FRS-551F PP(NATURAL)

48-1 3015914100 MOTOR C FAN

48-2 3011834710 FAN

53

54

3016808100 DRYER AS

DC-2213DWCA-3

PP OD3.17XD150

C1220T-M OD19.05XL135

3011474750 COVER MACH RM AS FRS-551F(F-US(N))

3015402300

3015402310

220~240V

110~127V

Q'ty

20BA* 20HA* 20DA* 20FA*

24BA* 24HA* 24DA* 24FA*

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

3

4

1

1

1

1

1

1

1

1

1

1

1

3

4

1

1

1

1

1

1

1

1

1

1

1

3

4

1

1

1

1

1

1

1

1

1

1 x

3

4

1

1

1

1

1

1

1

1

1

1 x

1

190

190-3

3017050730

3017050740

EVA AS

190-1 3014805200 SENSOR D AS

190-2 3017202000 FUSE TEMP AS

3012818100

3012818200

HEATER SHEATH AS

ACCUM SHEATH HEATER 220~240V/250W

ACCUM SHEATH HEATER 110~127V/250W

PBN-43

AC 250V 77C 10A

220~240V/250W

110~127V/250W

1

1

1

1

- Some parts can be chaged for improving their perfomance without notice.

- Above parts number doesn't describe your own colour & printing. Please remind!

1

1

1

1

Date A mendment Note

1 1

2

Freshfood Compartment

84

87

90

90-1

90-2

93

94

97

99

64

64-1

64-2

65

65-1

69

70

73

73

74

75

NO

77

80

81

82

83

PART-CODE PART NAME

3015911600 MOTOR R FAN

3011802200 FAN

3015911400 MOTOR R FAN

3013345201 INSU DAMP AS

3017905300 SOCKET R LAMP AS

3013602500

3013602800

LAMP F/R

3015507900 WINDOW R LAMP A

3017827460 SHELF INMOLDING R AS

3017831040 SHELF INMOLDING R AS

3012514512 GUIDE CASE A *L AS

3012514612 GUIDE CASE A *R AS

3011171280

3011171290

3011177760

3011177770

CASE CHILD AS

3011472900 COVER RETURN DUCT

3011172020

3011172040

3011178220

3011178260

3011473200

CASE VEGETB A AS

COVER V/CASE B

3011485400

3011172160

3011172170

3011178320

CASE VEGETB B AS

3011178360

3017827570 SHELF WINE AS

3018124000 SWITCH LAMP *R

3011474820 COVER M/F DUCT AS

3017905310 SOCKET R LAMP AS

3014805400 SENSOR R AS

3013600020

3013600050

LAMP AS

3015508000 WINDOW R LAMP B

3011171300 CASE EGG

3018200812

3018200802

TANK WATER AS

SPEC.

FR-S580CG

ABS OD3.17XD110

BL-2213DWRA-1

FR-S580EG

250V/1A

AC 240V 25W(S)

AC 125V 25W

MIPS

FRAME+PRINTED GLASS

FRAME+PRINTED GLASS

FR-S580EG(PP)

FR-S580EG(PP)

NO NANO, 55/58 MODEL

NANO, 55/58 MODEL

NANO, 66/69 MODEL

NO NANO, 66/69 MODEL

PP

NANO, 55/58 MODEL

NO NANO, 55/58 MODEL

NANO, 66/69 MODEL

NO NANO, 66/69 MODEL

GPPS, 55/58 MODEL

GPPS, 66/69 MODEL

NANO, 55/58 MODEL

NO NANO, 55/58 MODEL

NANO, 66/69 MODEL

NO NANO, 66/69 MODEL

FR-S580CG

SP201R-7DR

FRS-581 SILK

250V 1A

PBN-43B

240V/15W

120V/15W

MIPS

CASE+COVER+TRAY+GUIDE

FRS-551F

FR-S660CW x

1

1

1

1

1

1

1

1 x

1

4 x

3

3

1

Q'ty

20BA* 20DA* 24BA* 24DA*

20HA* 20FA* 24HA* 24FA*

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1 1 1 1

1

4 x

3

3

1

1 x

4

3

3 x

1 x

4

3

3 x x

1 x

1 x

1

1

- Some parts can be chaged for improving their perfomance without notice.

- Above parts number doesn't describe your own colour & printing. Please remind!

3 x

1 x

1 x

1

1 x

1

1

1

1

1

1

1 x

1

1

1

1

1

1

1

1

1

1

1 x

1 x

1 x

1

1 x

1 x

1 x

1

1 x

1

1

1

1

1

1

1 x

1

1

1

NO

74

75

100

104

104-1

104-2

107

109

109-1

110

110-1

115

117

118

119

120

122

123

125

128

131

132

133

134

PART-CODE PART NAME

3012514512 GUIDE CASE A *L AS

3012514612 GUIDE CASE A *R AS

3012514210 GUIDE DRN

3018914810 LOUVER F C AS

3011834500 FAN

3015911310 MOTOR F FAN

3018914900 LOUVER F D AS

3018914700 LOUVER F B AS

3014805300 SENSOR F AS

3018914630 LOUVER F A AS

3018914650 LOUVER F A AS

3017905220 SOCKET F LAMP AS

3000025900 CASE I/MAKER AS

3012517900 GUIDE G MOTR BRKT *R

3010634880

3010634890

3010634910

BRACKET GEARED MOTR AS

3010634920

3012517800 GUIDE G MOTR BRKT *L

3011176251

3011176202

CASE I/CRUSHER AS

3012204240

3012205730

FRAME I/MAKER AS

3011171870

3011171880

3011178060

CASE ICE AS

3011178070

3013602500

3013602800

LAMP F/R

3015507710 WINDOW F LAMP

3018124010 SWITCH LAMP *L

3017827120 SHELF F A AS

3017831800 SHELF F AS

3011171460

3011171440

3011177820

3011177870

3011171530

CASE F A AS

3011171540

3011177920

3011177970

CASE F B AS

4

SPEC.

FR-S580EG(PP)

FR-S580EG(PP)

EGI CABINET SCRAP(T0.5)

FR-S690CG

ABS OD130

DL-2213DWFA-2

FR-S580CG

FR-S580CG

PT-38

FR-S660CW/CD

FRS-581B

FR-S580EG(250V 0.5A)

FR-S660CW

ABS

110~127V, PLASTIC

TAIWAN, PLASTIC

220V/60HZ, PLASTIC

220~240V/50HZ, PLASTIC

ABS

SBS 55 MODEL

SBS 66 MODEL

FRS-582 SILK

FRS-691 SILK

NANO, 55/58 MODEL

NO NANO, 55/58 MODEL

NANO, 66/69 MODEL

NO NANO, 66/69 MODEL

AC 240V 25W(S)

AC 125V 25W

MIPS

SP201R-7DL

FRAME+SHELF+FIXTURE

FRAME+SHELF+FIXTURE

NANO, 55/58 MODEL

NO NANO, 55/58 MODEL

NANO, 66/69 MODEL

NO NANO, 66/69 MODEL

NANO, 55/58 MODEL

NO NANO, 55/58 MODEL

NANO, 66/69 MODEL

NO NANO, 66/69 MODEL x x

1

1

1

3 x

1 x

1 x x

Freezer Compartment

Q'ty

1

1 x x

1 x

20BA* 20DA* 24BA* 24DA*

20HA* 20FA* 24HA* 24FA*

4 2 4 2

1

1

4

1

1

1

1

2

1

1

1

1

1

1

4

1

1

1

1

1

1

2

1

1

1

1

1

1 x

1

1

1

1

1

1

1 x x

1 x x

1

1

1

1

1

1 x

1 x

1

1

1 x x x

1

1

1

3 x x

1

1

1

1 x

3 x

1 x x x x

1 x

1

1

1

1

1 x

3

1 x

1 x x

Freezer Door

NO PART-CODE PART NAME

135

136

137

137-1

3019019030 POCKET F *S

3019019150 POCKET F

3000054300

3000054310

3000039600

3000039620

3000039700

3000039720

ASSY F DR

3012314220 GASKET F DR AS

3011754100 DOOR F URT AS

137-2

137-3

137-4

137-5

137-6

3011754110 DOOR F URT AS

3012604500 HANDLE INTR DR AS

3010930300 CAP F INTR DR *T

3012201500 FRAME F DR *O

3014206300 PANEL F DR *T

3014206320 PANEL F DR *T

137-7

137-8

137-9

3017903702 SOCKET LAMP AS

3013600020

3013600050

LAMP AS

3014206600

3014206620

3014206400

PANEL F DR *U

3014206420

137-10 3010542200 BOX DISPNS I/SHUT AS

3015402100

3015403000

137-11

3015403120

VALVE SOL DISPNS

3015403200

137-12 3011485900 COVER I/FLAP AS

137-13 3018125800 SWITCH MICRO

137-14 3016304000 BUTTON DISPNS AS

137-15 3010964300 CAP F INTR DR *U AS

137-16 3012406200 GRILLE DISPNS

138

3011490200

3011490210

COVER DISPNS BOX AS

3011488320

3011488330

COVER F PCB AS

138-1

30143C4110 PCB FRONT AS

30143C2130 PCB FRONT AS

SPEC.

HIPS+SILK

HIPS+SILK

LMH4G, 55MODEL

BSH4G, BNH4G, 55MODEL

BSH4G, BNH4G, 58MODEL

LMH4G, 58MODEL

BSH4G, BNH4G, 66MODEL

LMH4G, 66MODEL

PVC

FR-T660DD

FR-T690DG

FR-T690DG

ABS+SPRAY

AL T1.5

BSH4G, BNH4G

LMH4G

250V 1A

240V/15W

120V/15W

BSH4G, BNH4G, DISPENSER

LMH4G, DISPENSER

BSH4G, BNH4G, BASIC

LMH4G, BASIC

.

220V/60HZ

220~240V/50HZ

110~127V/60HZ

110~115V/60HZ

FR-S660CW

VP333A-2D

FR-T660DD

FR-T690DG

ABS

BSH4G, BNH4G

LMH4G

BSH4G, BNH4G

LMH4G

FR-T66CDD

FR-T69CDG

1

5 x

1 x

1 x

1

1

1

1

1 x x x

1 x x x x x

1 x x

1 x

1

1

5 x

1 x

1

1

1 x

1

1

1 x x x

1 x x x x x

1 x

X

1 x

1

Q'ty

20BA* 20HA* 20DA* 20FA*

24BA* 24HA* 24DA* 24FA*

- Some parts can be chaged for improving their perfomance without notice.

- Above parts number doesn't describe your own colour & printing. Please remind!

2

3

1 x

1

1 x

1

1

1

1

1

1

1 x

1

1

1

1

1

1

1

1 x

1 x

2

3 x

1 x

1

1

1

1

1

1

1

1

1 x

1

1

1

1

1

1

1

1 x

1 x

5

Refrigerator Door

NO PART-CODE PART NAME

163

164

165

166

167

168

169

170

171

3019019400 POCKET DAIRY AS

3019019300 POCKET R *S

3019019830 POCKET R *M

3011474600 COVER H/BAR AS

3019022130 POCKET R H/BAR

3012514100 GUIDE R POKT

3012513400 GUIDE BOTL

3019019230 POCKET R

3000039500

3000039520

3000039400

3000039420

ASSY R DR

171-1

171-2

171-3

171-4

171-5

171-6

3012314520 GASKET R DR AS

3012314400 GASKET H/BAR B AS

3011754200 DOOR R URT AS

3011754210 DOOR R URT AS

3012201800

3010930500

FRAME R DR *O

CAP R INTR DR *T

171-7

3012604500 HANDLE INTR DR AS

3014206900

3014206920

PANEL R DR *T

171-8

171-9

3014207000

3014207020

3012314310

PANEL R DR *U

GASKET H/BAR A AS

171-10 3011437100 COVER H/BAR FRAME

171-11 3011756500 DOOR H/BAR AS

171-12

3014206500

3014206520

PANEL R DR

171-13 3010964400 CAP R INTR DR *U AS

SPEC.

POCKET+COVER

GP

HIPS SILK

FR-S580CR

HIPS SILK

HIPS

PP

HIPS+SILK

BSH4G, BNH4G

LMH4G

BSH4G, BNH4G, H/BAR

LMH4G, H/BAR

PVC

PVC

FR-T690DG

FR-T690DR

AL T1.5

ABS+SPRAY

FR-T690DG

BSH4G, BNH4G, H/BAR

LMH4G, H/BAR

BSH4G, BNH4G, H/BAR

LMH4G, H/BAR

PVC

ABS+SPRAY

FR-T690DR

BSH4G, BNH4G

LMH4G

FR-T690DG

20BA* 20HA* 20DA* 20FA*

24BA* 24HA* 24DA* 24FA*

1

1

1

1

1

1

1

1

2 x x

2

3

2

1 x

1 x

1 x

1

1

1 x x x x x

1

1

1

1

2

3

2 x

1 x

1

1

1

1

1

1

1

1

1

1

1 x

Q'ty

1 1

- Some parts can be chaged for improving their perfomance without notice.

- Above parts number doesn't describe your own colour & printing. Please remind!

2 x x

2

3

2

1 x

1 x

1 x

1

1

1 x x x x x

1

1

1

1

1

2

3

2 x

1

1

1

1 x

1

1 x

1

1

1

1

1

1

1

Date A mendment Note

6

Reference

1.

1. Electric Device

Compressor

Specification

HPL30YG-5

Part Code

395S130R50

DH90LHP5 3956190F50

MK183Q-L2U 3956183D50

HPL27YG-4-N 3956127R40

MK183C-L2U 3956183D10

HBL27YG-3 3952127R30

HCL27YG-2 3957127R20

2. Power Cord

Shape

Capacitor Run

Specification

400VAC/5

400VAC/5

350VAC/5

Part Code

3016401920

3016401920

3016401170

Capacitor Start

Part code Specification x

350VAC/ 5 ㎌ 3016401170

250VAC/12 ㎌ 3016405000

230VAC/10㎌ 400EL15130 200VAC/100㎌ 3016400100 x 200VAC/100㎌ 3016400100

Switch P Relay AS

Specification Part Code

308NHB, S330 3018129810

265RHB, S330

265RHB, S330

3018119470

3018129600

419RHB, S330 3018118131

445PHB, 4R7M 3018129610

783SHB, S068 3018119370

783SHB, S068 3018118170

Shape Description

CP-2PIN

Part Code

3011304100

Description

KP-550 (China)

Remark

220~240V/50Hz

220~240V/50Hz

220~240V/50Hz

220V/60Hz

110~127V/60Hz

110V/60Hz

127V/60Hz

Part Code

3011301030

CP-2PIN(Ferrite) 3011344221 KP-550 (Australia) 3011301060

KP-30 (MEXICO) 3011301741 ISRAEL (Ferrite) 3011301260

SA16A

(South Africa)

3011302160 BS-1363 (U.K) 3011344231

7

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement