Brocade Communications Systems | VDX 6720-60 | BROCADE VDX 6720 SWITCH

www.brocade.com
DATA SHEET
BROCADE
VDX 6720
SWITCH
DATA CENTER
HIGHLIGHTS
•Simplifies and automates network
architectures and enables elastic
cloud networking with Brocade VCS
Fabric technology
•Manages an entire VCS fabric as a single
switch with Brocade VCS Logical Chassis
•Delivers high performance and ultra-low
latency through wire-speed ports with
600-nanosecond port-to-port latency and
automated hardware-based Inter-Switch
Link (ISL) trunking
•Provides efficiently load-balanced
multipathing at Layers 1, 2, and 3,
and multiple Layer 3 gateways
•Simplifies virtualized server management
by providing Virtual Machine (VM) mobility
with dynamic server profile configuration
and migration
•Provides storage connectivity for Fibre
Channel over Ethernet (FCoE), iSCSI,
and NAS
Revolutionizing the Way Data
Center Networks Are Built
Seeking better ways to build clouds and
virtualized data centers, today’s IT
organizations are turning to highperformance networking solutions that
increase flexibility through leading-edge
technologies. The Brocade® VDX® 6720
Switch is a high-performance 10 Gigabit
Ethernet (GbE) fixed configuration switch
with LAN ports that supports the most
demanding business applications. It is
specifically designed to improve network
utilization, maximize application availability,
increase scalability, and dramatically
simplify network architecture in virtualized
data centers. The Brocade VDX 6720 with
Brocade VCS® Fabric technology is an ideal
platform for a variety of Top-of-Rack (ToR)
fabric deployments (see Figure 1).
The Brocade VDX 6720 is available in two
models—the 2U Brocade VDX 6720-60 with
60 10 GbE LAN ports, and the 1U Brocade
VDX 6720-24 with 24 10 GbE LAN ports.
Both models deliver high performance for
intra-rack traffic in virtualized environments,
provide ultra-low latency of 600
nanoseconds for the same ASIC on the
switch, and offer low power consumption,
making the Brocade VDX 6720 ideal for
demanding data center environments. This
helps organizations design a network with
no oversubscription for deterministic
network performance and improved
application response times. In addition,
the Brocade VDX 6720 provides storage
connectivity for Fibre Channel over Ethernet
(FCoE), iSCSI, and NAS.
AN INTELLIGENT FOUNDATION FOR
CLOUD COMPUTING
Brocade VCS Fabric technology is an
innovative technology that enables
organizations to build high-performance,
cloud-optimized data centers while
preserving existing network designs and
cabling, and gaining active-active server
connections. For scale-out fabric
architectures, Brocade VCS Fabric
•Flexible: Can be architected in any
topology to best meet the needs of
any variety of workloads
•Resilient: Uses multiple “least cost”
paths for high performance and high
reliability
Core
Core
Edge
•Flatter: Eliminates the need for
Spanning Tree Protocol (STP), while
being completely interoperable with
existing Ethernet networks
•These features, along with
virtualization-specific enhancements,
make it easier to explicitly address the
challenges of VM automation within the
network, thereby facilitating better
IT automation.
Protocol convergence, such as Fibre
Channel over Ethernet (FCoE), may also
be a feature, intended as a means of
better bridging LAN and Storage Area
Network (SAN) traffic.
Learn more about Ethernet fabrics at
www.brocade.com/ethernet-fabric.
technology allows organizations to flatten
network designs, provide Virtual Machine
(VM) mobility without network
reconfiguration, and more efficiently
manage the entire fabric. Learn more
about Brocade VCS Fabric technology
at www.brocade.com/vcs.
Servers with 10 Gbps Connections
Servers with 10 Gbps Connections
REMOTE
DATA CENTER
PRIMARY
DATA CENTER
Public
Network
More advanced Ethernet fabrics
borrow further from Fibre Channel fabric
constructs:
•Management can then be domainbased rather than device-based,
and defined by policy rather than
repetitive procedures.
Scalability
Figure 1.
Compared to classic Ethernet architectures, Ethernet fabrics—such as Brocade VCS
fabrics—allow all paths to be active and provide greater scalability while reducing
management complexity.
•Elastic: Scales easily up and down
as needed
•They are self-forming and function
as a single logical entity, in which all
switches automatically know about
each other and all connected physical
and logical devices.
Ethernet Fabric Architecture
Aggregation
Compared to classic hierarchical Ethernet
architectures, Ethernet fabrics provide
higher levels of performance, utilization,
availability, and simplicity. They are
designed to be:
Classic Hierarchical Ethernet Architecture
Access
WHAT IS AN ETHERNET FABRIC?
VM
Core
routers
VM
VM
VCS fabric
extension
Layer 4–7
application delivery
VCS fabric
extension
VM
Native
Fibre Channel
Security services
(firewall, encryption)
SAN
VM
VM
VM
VM
VM
Blade
servers
VM
FCoE/iSCSI/NAS
storage
Dedicated Fibre
Channel SAN for
Tier 1 applications
Rack-mount
servers
Figure 2.
Brocade VCS Fabric technology simplifies the network architecture, enables unified storage
connectivity, improves VM mobility, and allows the seamless insertion of services.
UNMATCHED SIMPLICITY AND
AUTOMATION
Brocade VCS Fabric technology helps
streamline network operations and speed
deployment with embedded features that
enable automatic configuration and
management. These features include:
•Brocade VCS Logical Chassis: The
VCS Logical Chassis feature allows
organizations to manage an entire VCS
fabric as a single switch. This single point
of management eliminates the need to
manually configure and manage each
switch, simplifying management and
reducing operational costs. As additional
switches are added, they inherit the
configuration of the fabric, allowing the
network to scale out with ease. For more
information about VCS Logical Chassis,
read the white paper An Overview of
Brocade VCS Logical Chassis.
•Self-forming and self-healing fabric:
Configuration is simplified with selfforming fabrics. Configuration and device
information is known by all switches,
allowing fabric switches to be added
or removed, and physical or virtual
servers to be relocated—without the
fabric requiring manual reconfiguration.
In addition, fabrics are self-healing,
increasing network resiliency. The fabric
redirects traffic if a link fails, helping to
ensure uninterrupted traffic flow and
prevent data loss.
MAXIMUM EFFICIENCY
Brocade VCS Fabric technology provides the
foundation for a flexible and responsive
network infrastructure while delivering
maximum efficiency.
Optimized East-West Traffic
Traditional data centers are architected with
a rigid, three-tier tree topology, optimized for
a client-server computing environment in
which traffic travels north to south. This
compromises performance, increases
latency, and creates bottlenecks. With the
increased prevalence of virtualization and
Web-based application architectures, data
center network traffic is now predominantly
east-west or server-server. The Brocade VCS
fabric was specifically designed and
optimized to address these traffic patterns
by moving traffic through any of the active
paths and avoiding the multiple hops
required in other tiered topologies.
Multiple Load-Balanced Paths
at Layers 1–3
Brocade VCS Fabric technology enables
highly elastic Layer 2 and Layer 3 domains
with extremely efficient load balancing and
multiple active Layer 3 gateways, in addition
to Layer 2 Equal Cost Multi-Path (ECMP) and
Brocade ISL Trunking. In the event of a
failure, traffic is automatically routed to the
closest path, providing higher resilience and
greater application uptime. Multilayer
multipathing helps improve network
utilization, reduce latency, and increase
overall network performance. Read the
white paper Setting a New Standard for
Network Efficiency with VCS Fabric
Multilayer Multipathing Capabilities
to learn more.
Optimized for Virtualization
Brocade VCS Fabric technology offers
unique features to support virtualized
server and storage environments (see
Figure 2), including:
•Zero-touch VM discovery:
Brocade VM-Aware Network Automation
eliminates the manual configuration of
port profiles when a VM is added to the
fabric or moved, providing an additional
level of automation. The VCS fabric
directly communicates with VMware
vCenter, automatically downloading
all port profile information and the
associated MAC address, and distributes
the VM-specific information to all switches
within the fabric. When the VM moves,
no additional configuration is required.
•Automatic Migration of Port Profiles:
During a VM migration, network switch
ports must be dynamically configured to
ensure that the VM traffic experiences
consistent policies and configurations.
The Brocade Automatic Migration of
Port Profiles (AMPP) feature enables a
seamless migration, since the VCS fabric
is aware of port profiles and automatically
tracks them as they move. Implemented
in a hypervisor-agnostic manner, port
profiles and MAC address mapping are
created on any switch in the fabric.
This mapping provides the logical flow
for traffic from the source port to the
destination port. As a VM migrates,
the destination port in the fabric
learns of the MAC address move and
automatically activates the port profile
configuration within a single fabric or
across separate fabrics.
PROACTIVE MONITORING
Brocade Fabric Watch is an innovative
switch health monitoring feature available
on the Brocade VDX 6720. Fabric Watch
monitors the health of certain switch
components and, based on the threshold
set, declares each component as marginal
or down.
EASE OF USE AUGMENTED BY
BROCADE NETWORK ADVISOR
Brocade Network Advisor is an easy-to-use
network management platform for
advanced management of Brocade VCS
fabrics and Brocade VDX switches across
the entire network lifecycle. Organizations
can use Brocade Network Advisor to
manage a VCS fabric as a single entity
or to drill down to individual Brocade VDX
switches for fault, inventory, or performance
management—and to manage multiple VCS
fabrics in parallel.
Brocade Network Advisor also provides
simplified management of AMPP
configurations, and integrity checks can be
performed across physical Brocade VDX
configurations, either in the same fabric or
across different VCS fabrics. In addition,
Brocade Network Advisor enables VM-level
monitoring and can help identify top-talker
applications leveraging sFlow across the
fabric. Finally, Brocade Network Advisor
provides VCS fabric diagnostics, including
visualization of VCS fabric traffic paths and
network latency monitoring that enables
fault isolation via hop-by-hop inspection.
For details, visit www.brocade.com/
management.
BROCADE GLOBAL SERVICES
Brocade Global Services has the expertise
to help organizations build scalable,
efficient cloud infrastructures. Leveraging
15 years of expertise in storage, networking,
and virtualization, Brocade Global Services
delivers world-class professional services,
technical support, and education services,
enabling organizations to maximize their
Brocade investments, accelerate new
technology deployments, and optimize the
performance of networking infrastructures.
AFFORDABLE ACQUISITION OPTIONS
Brocade Capital Solutions helps
organizations easily address their IT
requirements by offering flexible network
acquisition and support alternatives.
Organizations can select from purchase,
lease, Brocade Network Subscription, and
Brocade Subscription Plus options to align
network acquisition with their unique
capital requirements and risk profiles.
To learn more, visit www.Brocade.com/
CapitalSolutions.
MAXIMIZING INVESTMENTS
To help optimize technology investments,
Brocade and its partners offer complete
solutions that include professional services,
technical support, and education. For more
information, contact a Brocade sales
partner or visit www.brocade.com.
BROCADE VDX 6720 FEATURE OVERVIEW
Brocade VDX 6720-24
Brocade VDX 6720-60
Switching bandwidth (data rate, full duplex)
480 Gbps
1200 Gbps
Port-to-port latency
600 nanoseconds within 10-port group
600 nanoseconds within 10-port group
Form factor
1U
2U
Dimensions and weight
Width: 42.88 cm (16.88 in.)
Width: 42.88 cm (16.88 in.)
Height: 4.32 cm (1.70 in.)
Height: 8.89 cm (3.50 in.)
Depth: 38.10 cm (15.00 in.)
Depth: 43.18 cm (17.00 in.)
Weight: 7.30 kg (16.10 lb)
Weight: 15.88 kg (35.00 lb)
1/10 GbE SFP+ ports
24
60
Ports on Demand (PoD) increments
16, 24
40, 50, 60
Power supplies
Two hot-swappable, load-sharing
Two hot-swappable, load-sharing
Cooling fans
N+1 redundant, integrated into power supplies
N+1 redundant, three hot-swappable fan units
BROCADE VDX 6720 SPECIFICATIONS
Scalability Information1
Connector options
1 GbE copper SFP options
1000Base-SX and 1000Base-LX
10 Gbps SFP+ options: 1/3/5 m direct-attached copper (Twinax)
10 GbE SR and 10 GbE LR
Out-of-band Ethernet management: RJ-45 (fixed)
Remote lights-out management: 10/100/1000 BaseT Ethernet
Console management: RJ45 to RS-232 (fixed)
Firmware and diagnostic: USB
1
Maximum VLANs
4096
Maximum MAC addresses
32,000
Maximum port profiles (AMPP)
256
Maximum Layer 2 multicast groups
2000
Maximum Spanning Tree instances
32
Maximum per-port priority pause level
8
Maximum LAG groups in a VCS fabric
512
Maximum members in a standard LAG
16
Maximum MAC addresses in a VCS fabric
30,000
Maximum switches in a VCS fabric
32
Maximum ECMP paths in a VCS fabric
8
Maximum trunk members for VCS fabric ports
8
Maximum switches across which a vLAG can span
4
Maximum members in a vLAG
32
Maximum jumbo frame size
9208 bytes
Queues per port
8
DCB Priority Flow Control (PFC) classes
8
Maximum Layer 2 ACLs
1000
Maximum Layer 3 ACLs
1000
Maximum ARP entries
12,000
Maximum IPv4 routes
2000
Operating system
Brocade Network OS
Layer 2 switching features
• MAC Learning and Aging
• Static MAC Configuration
• Link Aggregation Control Protocol (LACP)
IEEE 802.3ad/802.1AX
• Virtual Local Area Networks (VLANs)
• VLAN Encapsulation 802.1Q
• Rapid Spanning Tree Protocol (RSTP) 802.1w
• Multiple Spanning Tree Protocol (MSTP) 802.1s
• Per-VLAN Spanning Tree (PVST+/PVRST+)
• Private VLAN (PVLAN)
• STP PortFast and PortFast BPDU Guard
• STP Root Guard
• STP over VCS
• Layer 2 Access Control Lists (ACLs)
• Address Resolution Protocol (ARP) RFC 826
• IGMP v1/v2 Snooping
• Pause Frames 802.3x
Layer 3 switching features
• OSPF
• VRRP and VRRP-E support
• Static routes
Please refer to the latest version of the release notes for the most up-to-date scalability numbers.
Brocade VCS Fabric technology features
• Automatic Fabric Formation
• Distributed Fabric Services
• Transparent LAN Services
• Virtual Link Aggregation Group (vLAG) spanning
multiple physical switches
• Switch Beaconing
• Distributed Configuration Management
• Transparent Interconnection of Lots of Links
(TRILL)
• Equal Cost Multi-Path (ECMP)
• Automatic Migration of Port Profiles (AMPP)
• VM-Aware Network Automation
DCB features
• Priority-based Flow Control (PFC) 802.1Qbb
• Enhanced Transmission Selection (ETS)
802.1Qaz
• Data Center Bridging eXchange (DCBX)
• DCBX Application Type-Length-Value (TLV) for
FCoE and iSCSI
FCoE features
• Multihop Fibre Channel over Ethernet (FCoE);
requires Brocade VCS Fabric technology
• FC-BB5 compliant Fibre Channel Forwarder (FCF)
• Native FCoE forwarding
• End-to-end FCoE (initiator to target)
• FCoE Initialization Protocol (FIP) v1 support for
FCoE device login and initialization
• Name Server-based zoning
• Supports connectivity to FIP Snooping Bridge
(FSB) device
Quality of Service (QoS)
• Eight priority levels for QoS
• Class of Service (CoS) IEEE 802.1p
• DSCP Trust
• DSCP to Traffic Class Mutation
• Random Early Discard
• Per-port QoS configuration
• Scheduling: Strict Priority (SP), Shaped Deficit
Weighted Round-Robin (SDWRR)
-- DSCP to CoS Mutation
-- DSCP to DSCP Mutation
Switch health monitoring
• Fabric Watch monitoring and notification
Management
Management and control
• IPv4/IPv6 management
• Industry-standard Command Line Interface (CLI)
• Remote lights out management (future update)
• In-band management (standalone mode)
• Link Layer Discovery Protocol (LLDP) IEEE
802.1AB
• Logical chassis management
• MIB II RFC 1213 MIB
• Switch Beaconing
Security
• Port-based Network Access Control 802.1X
• RADIUS
• TACACS+
• Secure Shell (SSHv2)
• BPDU Drop
• Lightweight Directory Access Protocol (LDAP)
• Secure Control Protocol
• Switched Port Analyzer (SPAN)
• Telnet
• SNMP v1, v2C, v3
• sFlow RFC 3176
• Out-of-band management
• RMON-1, RMON-2
• NTP
• Management Access Control Lists (ACLs)
• Role-Based Access Control (RBAC)
Mechanical
Enclosure
Front-to-rear, rear-to-front airflow; 1U, 19-inch EIA-compliant; power from non-port side
Environmental
Temperature
Operating: 0°C to 40°C (32°F to 104°F)
Non-operating and storage: −25°C to 70°C (−13°F to 158°F)
Humidity
Operating: 10% to 85% non-condensing
Non-operating and storage: 10% to 90% non-condensing
Altitude
Operating: Up to 3000 meters (9842 feet)
Non-operating and storage: Up to 12 kilometers (39,370 feet)
Shock
Operating: 20 g, 6 ms half-sine
Non-operating and storage: Half-sine, 33 g 11 ms, 3/eg Axis
Vibration
Operating: 0.5 g sine, 0.4 grms random, 5 to 500 Hz
Non-operating and storage: 2.0 g sine, 1.1 grms random, 5 to 500 Hz
Airflow
Brocade VDX 6720-24
Maximum: 53 CFM
Nominal: 35 CFM
Brocade VDX 6720-60
Maximum: 115 CFM
Nominal: 76 CFM
Heat dissipation
450 BTU/hr (24-port switch); 1126 BTU/hr (60-port switch)
BROCADE VDX 6720 SPECIFICATIONS (CONTINUED)
Power
Power supplies
Two internal, redundant, field-replaceable, load-sharing AC power supplies
Power inlet
C13
Input voltage
85 to 256 VAC nominal
Input line frequency
47 to 63 Hz
Inrush current
50 amps max
Maximum current
3.5 amps max (24-port switch); 7 amps max (60-port switch)
Maximum power consumption
132 watts (24-port switch); 330 watts (60-port switch)
Safety Compliance
• Bi-Nat UL/CSA 60950-1 Second Edition
• CAN/CSA-C22.2 No. 60950-1 Second Edition
• EN 60950-1 Second Edition
• IEC 60950-1 Second Edition
• GB4943-2001 and GB9254-1998
• CNS 14336(94)
EMC
• FCC Class A
• ICES A
• VCCI-Class A
• CE
• C
• BSMI
• GOST
• KC Class A
• CCC
Immunity
• ANSI C63.4
• ICES-003 Class A
• CISPR22 and JEIDA (Harmonics)
• EN55022 Class A and EN55024
• CISPR22
• AS/NZS CISPR22
• CNS 13438(95)
• 51318.22-99 and 51318.24-99
• KN22 and KN24
• GB17625.1-2003
Environmental Regulatory Compliance
• RoHS-6 (with lead exemption) Directive 2002/95/EC
Standards Compliance
The Brocade VDX 6720 products conform to the following Ethernet standards:
• IEEE 802.1D Spanning Tree Protocol
• IEEE 802.1s Multiple Spanning Tree
• IEEE 802.1w Rapid reconfiguration of Spanning Tree Protocol
• IEEE 802.3ad Link Aggregation with LACP
• IEEE 802.3ae 10G Ethernet
• IEEE 802.1Q VLAN Tagging
• IEEE 802.1p Class of Service Prioritization and Tagging
• IEEE 802.1v VLAN Classification by Protocol and Port
• IEEE 802.1AB Link Layer Discovery Protocol (LLDP)
• IEEE 802.3x Flow Control (Pause Frames)
• IEEE 802.3ab 1000BASE-T
• IEEE 802.3z 1000BASE-X
The following draft versions of the Data Center Bridging (DCB) and Fibre Channel over Ethernet (FCoE) standards
are also supported on the Brocade VDX 6720:
• IEEE 802.1Qbb Priority-based Flow Control
• IEEE 802.1Qaz Enhanced Transmission Selection
• IEEE 802.1 DCB Capability Exchange Protocol (Proposed under the DCB Task Group of IEEE 802.1 Working Group)
• FC-BB-5 FCoE (Rev 2.0)
RFC Support
RFC 768
User Datagram Protocol (UDP)
RFC 783
TFTP Protocol (revision 2)
RFC 791
Internet Protocol (IP)
RFC 792
Internet Control Message Protocol (ICMP)
RFC 793
Transmission Control Protocol (TCP)
RFC 826
ARP
RFC 854
Telnet Protocol Specification
RFC 894
A Standard for the Transmission of IP Datagram over Ethernet Networks
RFC 1027
Using ARP to Implement Transparent Subnet Gateways (Proxy ARP)
RFC 1112
IGMP v1
RFC 1157
Simple Network Management Protocol (SNMP) v1 and v2
RFC 1492
TACACS+
RFC 1519
Classless Interdomain Routing (CIDR)
RFC 1584
Multicast Extensions to OSPF
RFC 1765
OSPF Database Overflow
RFC 1812
Requirements for IP Version 4 Routers
RFC 2068
HTTP Server
RFC 2131
Dynamic Host Configuration Protocol (DHCP)
RFC 2154
OSPF with Digital Signatures (Password, MD-5)
RFC 2236
IGMP v2
RFC 2267
Network Ingress Filtering
RFC 2328
OSPF v2 (edge mode)
RFC 3768
VRRP
RFC 2370
OSPF Opaque Link-State Advertisement (LSA) Option—Partial Support
RFC 2474
Definition of the Differentiated Services Field in the IPv4 and IPv6 Headers
RFC 2571
An Architecture for Describing SNMP Management Frameworks
RFC 2865
Remote Authentication Dial In User Service (RADIUS)
RFC 3101
The OSPF Not-So-Stubby Area (NSSA) Option
RFC 3176
sFlow
RFC 3137
OSPF Stub Router Advertisement
RFC 4510
Lightweight Directory Access Protocol (LDAP): Technical Specification Road Map
RFC 4292
IP Forwarding MIB
RFC 4293
Management Information Base for the Internet Protocol (IP)
RFC 3411
An Architecture for Describing SNMP Frameworks
RFC 3412
Message Processing and Dispatching for the SNMP
RFC 3413
Simple Network Management Protocol (SNMP) Applications
RFC 2460
Internet Protocol, Version 6 (v6) Specification (on management interface )
RFC 2464
Transmission of IPv6 Packets over Ethernet Networks (on management interface)
RFC 2474
Definition of the Differentiated Services Field (DS Field) in the IPv4 and IPv6 Headers (only for IPv4)
www.brocade.com
DATA SHEET
BROCADE VDX 6720 ORDERING INFORMATION
SKU
Description
Comments
BR-VDX6720-16-F
Brocade VDX 6720, 16P SFP+, AC, non-port side exhaust airflow
Base SKU
BR-VDX6720-16-R
Brocade VDX 6720, 16P SFP+, AC, port side exhaust airflow
Base SKU
BR-VDX6720-24-F
Brocade VDX 6720, 24P SFP+, AC, non-port side exhaust airflow
Base SKU
BR-VDX6720-24-R
Brocade VDX 6720, 24P SFP+, AC, port side exhaust airflow
Base SKU
BR-VDX6720-40-F
Brocade VDX 6720, 40P SFP+, AC, non-port side exhaust airflow
Base SKU
BR-VDX6720-40-R
Brocade VDX 6720, 40P SFP+, AC, port side exhaust airflow
Base SKU
BR-VDX6720-60-F
Brocade VDX 6720, 60P SFP+, AC, non-port side exhaust airflow
Base SKU
BR-VDX6720-60-R
Brocade VDX 6720, 60P SFP+, AC, port side exhaust airflow
Base SKU
BR-VDX6720-24POD-01
8-port PoD license for Brocade VDX 6720-32
Software orderable
BR-VDX6720-60POD-01
10-port PoD license for Brocade VDX 6720-76
Software orderable
BR-VDX6720-24VCS-01
VCS software license for Brocade VDX 6720-16, Brocade VDX 6720-24
Software orderable
BR-VDX6720-60VCS-01
VCS software license for Brocade VDX 6720-40, Brocade VDX 6720-60
Software orderable
XBR-250WPSAC-F
FRU 250W ACPS/FAN, non-port side exhaust airflow
FRU
BR-VDX 6720-24FCOE-01
FCoE software license for 16- and 24-port SKU
Software orderable
BR-VDX 6720-60FCOE-01
FCoE software license for 40- and 60-port SKU
Software orderable
XBR-250WPSAC-R
FRU 250W ACPS/FAN, port side exhaust airflow
FRU
XBR-250WPSAC-F
FRU 250W ACPS/FAN, non-port side exhaust airflow
FRU
XBR-500WPSAC-R
FRU 500W ACPS, port side exhaust airflow
FRU
XBR-500WPSAC-F
FRU 500W ACPS, non-port side exhaust airflow
FRU
XBR-FAN-80-F
FRU FAN, 80MM, non-port side exhaust airflow
FRU
XBR-FAN-80-R
FRU FAN, 80MM, port side exhaust airflow
FRU
XBR-000190 (1-pack)
1 GbE copper
Optics
E1MG-SX-OM (1-pack)
E1MG-SX-OM-8 (8-pack)
1000Base-SX
Optics
E1MG-LX-OM (1-pack)
E1MG-LX-OM-8 (8-pack)
1000Base-LX
Optics
10G-SFPP-SR (1-pack)
10G-SFPP-SR-8 (8-pack)
10 Gbps SR
Optics
10G-SFPP-LR (1-pack)
10G-SFPP-LR-8 (8-pack)
10 Gbps LR
Optics
10G-SFPP-TWX-0101 (1-pack)
10G-SFPP-TWX-0108 (8-pack)
1 m Twinax copper cable
Optics
10G-SFPP-TWX-0301 (1-pack)
10G-SFPP-TWX-0308 (8-pack)
3 m Twinax copper cable
Optics
10G-SFPP-TWX-0501 (1-pack)
10G-SFPP-TWX-0508 (8-pack)
5 m Twinax copper cable
Optics
Corporate Headquarters
San Jose, CA USA
T: +1-408-333-8000
info@brocade.com
European Headquarters
Geneva, Switzerland
T: +41-22-799-56-40
emea-info@brocade.com
Asia Pacific Headquarters
Singapore
T: +65-6538-4700
apac-info@brocade.com
© 2013 Brocade Communications Systems, Inc. All Rights Reserved. 07/13 GA-DS-1524-07
ADX, AnyIO, Brocade, Brocade Assurance, the B-wing symbol, DCX, Fabric OS, ICX, MLX, MyBrocade, OpenScript, VCS,
VDX, and Vyatta are registered trademarks, and HyperEdge, The Effortless Network, and The On-Demand Data Center
are trademarks of Brocade Communications Systems, Inc., in the United States and/or in other countries. Other brands,
products, or service names mentioned may be trademarks of their respective owners.
Notice: This document is for informational purposes only and does not set forth any warranty, expressed or implied,
concerning any equipment, equipment feature, or service offered or to be offered by Brocade. Brocade reserves the
right to make changes to this document at any time, without notice, and assumes no responsibility for its use. This
informational document describes features that may not be currently available. Contact a Brocade sales office for
information on feature and product availability. Export of technical data contained in this document may require an
export license from the United States government.
Download PDF